ANNEXURE D: BILLS OF QUANTITIES
2
TABLE OF CONTENTS
1 GENERAL .................................................................................................................................................. 3
2 PRELIMINARIES & GENERALS ............................................................................................................. 4
3 BUILDING 1 ............................................................................................................................................... 5
4 BUILDING 2 ............................................................................................................................................... 7
5 BUILDING 3 ............................................................................................................................................. 12
6 BUILDING 4 ............................................................................................................................................. 16
7 BUILDING 8 ............................................................................................................................................. 23
8 BUILDING 10 ........................................................................................................................................... 28
9 BUILDING 16 ........................................................................................................................................... 32
10 BUILDING 22 ....................................................................................................................................... 35
11 BUILDING 23 ....................................................................................................................................... 42
12 BUILDING 34 ....................................................................................................................................... 47
13 BUILDING 35 ....................................................................................................................................... 50
14 BUILDING 36 ....................................................................................................................................... 53
15 BUILDING 40 ....................................................................................................................................... 56
16 BUILDING 41 ....................................................................................................................................... 58
17 BUILDING 42 ....................................................................................................................................... 64
18 BUILDING 46 ....................................................................................................................................... 68
19 MISCELLANEOUS .............................................................................................................................. 73
20 SUMMARY ........................................................................................................................................... 74
3
1 GENERAL
The tenderers must complete the Bills of Quantities and detail unit rates and total amount for each item. All
rates and prices exclude VAT.
NOTE:
Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring in the
priced Bills of Quantities cannot be considered as having an effect on the tender amount.
No alteration, erasure or addition is to be made in the text of the Bills of Quantities. Should any alteration,
erasure or addition be made it will not be recognized but the original wording of the Bills of Quantities will
be adhered to.
The Employer will check the completed Bills of Quantities and reserves the right to adjust any individual
price and to rectify and discrepancy whilst the total tender price as quoted remains unaltered.
The quantities given in the Bills for video cables, power cables, cable markers, and data cables cannot be
regarded as exact and are subject to measurement on site after completion of the installation and adjustments
will be made according to the unit rates given in the Bills.
The quantities given in the Bill of Quantities are estimates only, and subject to re-measuring during the
execution of the work. The Contractor shall obtain the Engineer’s detailed instructions for all work before
ordering any materials or executing work or making arrangement for it.
The Works as finally completed in accordance with the Contract shall be measured and paid for as specified
in the Bill of Quantities and in accordance with the General and Special Conditions of Contract, the
Specifications and Project Specifications and the Drawings. Unless otherwise stated, items are measured net
in accordance with the Drawings, and no allowance has been made for waste.
The validity of the contract will in no way be affected by differences between the quantities in the Bill of
Quantities and the quantities finally certified for payment.
4
2 PRELIMINARIES & GENERALS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 General
Allow for complying with all special preliminary
and general conditions and contract and labour
requirements, for site establishment and providing
a site office Sum 1
2 Permits and notices
Allow for coordination with other contractors Sum 0
3 Storage
Provide for storage of plant, materials and
equipment on site including protection thereof Sum 1
5 Transport
Transport of material shall include delivery costs Sum 1
6 OHS file Sum 1
7 After Hours / Weekend Work Hrs 80
Total amount carried forward to summary page
5
3 BUILDING 1
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets,
fitting screws, mounting bases and accessories to
complete the installation.
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 50
(b) Install m 50
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 3
(b) Install ea 3
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 2
(b) Install ea 2
5 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
6 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
7 Network Card
(a) Supply ea 1
(b) Install ea 1
8 System Configuration and Testing Sum 1
Subtotal Carried To The Next Page
6
Subtotal From The Previous Page
9 Signage
Provide zone diagram and associated signage. Sum 1
10
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round boxes,
end boxes and suspension material to make the
installation complete
(a) Supply m 10
(b) Install m 10
11
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 50
(b) Install m 50
Total amount carried forward to summary page
7
4 BUILDING 2
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets,
fitting screws, mounting bases and accessories to
complete the installation.
BASEMENT
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 120
(b) Install m 120
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 13
(b) Install ea 13
3 Analogue Addressable Manual Call Points
(a) Supply ea 3
(b) Install ea 3
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 6
(b) Install ea 6
5
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round boxes,
end boxes and suspension material to make the
installation complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation
complete
(a) Supply m 120
(b) Install m 120
Subtotal Carried To The Next Page
8
Subtotal From The Previous Page
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 270
(b) Install m 270
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 30
(b) Install ea 30
3 Analogue Addressable Manual Call Points
(a) Supply ea 10
(b) Install ea 10
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 9
(b) Install ea 9
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 Network Card
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
9
Subtotal From The Previous Page
8 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
11
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 20
(b) Install m 20
12
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 270
(b) Install m 270
FIRST FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 290
(b) Install m 290
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 34
(b) Install ea 34
3 Analogue Addressable Manual Call Points
(a) Supply ea 11
(b) Install ea 11
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 9
(b) Install ea 9
Subtotal Carried To The Next Page
10
Subtotal From The Previous Page
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 20
(b) Install m 20
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 290
(b) Install m 290
SECOND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 270
(b) Install m 270
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 28
(b) Install ea 28
3 Analogue Addressable Manual Call Points
(a) Supply ea 7
(b) Install ea 7
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 10
(b) Install ea 10
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 10
(b) Install m 10
Subtotal Carried To The Next Page
11
Subtotal From The Previous Page
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 270
(b) Install m 270
THIRD FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 140
(b) Install m 170
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 14
(b) Install ea 14
3 Analogue Addressable Manual Call Points
(a) Supply ea 5
(b) Install ea 5
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 6
(b) Install ea 6
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 140
(b) Install m 140
Total amount carried forward to summary page
12
5 BUILDING 3
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets,
fitting screws, mounting bases and accessories to
complete the installation.
BASEMENT
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 65
(b) Install m 65
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 7
(b) Install ea 7
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 2
(b) Install ea 2
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 65
(b) Install m 65
Subtotal Carried To The Next Page
13
Subtotal From The Previous Page
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 140
(b) Install m 140
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 15
(b) Install ea 15
3 Analogue Addressable Manual Call Points
(a) Supply ea 6
(b) Install ea 6
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 5
(b) Install ea 5
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 Network Card
(a) Supply ea 1
(b) Install ea 1
8 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
Subtotal Carried To The Next Page
14
Subtotal From The Previous Page
11
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
12
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 140
(b) Install m 140
FIRST FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 225
(b) Install m 225
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 26
(b) Install ea 26
3 Analogue Addressable Manual Call Points
(a) Supply ea 9
(b) Install ea 9
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 6
(b) Install ea 6
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
Subtotal Carried To The Next Page
15
Subtotal From The Previous Page
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 225
(b) Install m 225
SECOND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 230
(b) Install m 230
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 26
(b) Install ea 26
3 Analogue Addressable Manual Call Points
(a) Supply ea 8
(b) Install ea 8
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 7
(b) Install ea 7
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 230
(b) Install m 230
Total amount carried forward to summary page
16
6 BUILDING 4
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets, fitting
screws, mounting bases and accessories to complete the
installation.
LOWER GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 65
(b) Install m 65
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 8
(b) Install ea 8
3 Analogue Addressable Manual Call Points
(a) Supply ea 3
(b) Install ea 3
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 4
(b) Install ea 4
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 65
(b) Install m 65
Subtotal Carried To The Next Page
17
Subtotal From The Previous Page
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 85
(b) Install m 85
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 9
(b) Install ea 9
3 Analogue Addressable Manual Call Points
(a) Supply ea 4
(b) Install ea 4
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 4
(b) Install ea 4
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
8 Network Card
(a) Supply ea 1
(b) Install ea 1
9 System Configuration and Testing Sum 1
Subtotal Carried To The Next Page
18
Subtotal From The Previous Page
11
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
12
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 85
(b) Install m 85
FIRST FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 230
(b) Install m 230
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 26
(b) Install ea 26
3 Analogue Addressable Manual Call Points
(a) Supply ea 8
(b) Install ea 8
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 9
(b) Install ea 9
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
Subtotal Carried To The Next Page
19
Subtotal From The Previous Page
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 230
(b) Install m 230
SECOND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 220
(b) Install m 220
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 26
(b) Install ea 26
3 Analogue Addressable Manual Call Points
(a) Supply ea 8
(b) Install ea 8
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 9
(b) Install ea 9
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 220
(b) Install m 220
Subtotal Carried To The Next Page
20
Subtotal From The Previous Page
THIRD FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 160
(b) Install m 160
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 20
(b) Install ea 20
3 Analogue Addressable Manual Call Points
(a) Supply ea 6
(b) Install ea 6
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 6
(b) Install ea 6
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 160
(b) Install m 160
FOURTH FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 65
(b) Install m 65
Subtotal Carried To The Next Page
21
Subtotal From The Previous Page
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 7
(b) Install ea 7
3 Analogue Addressable Manual Call Points
(a) Supply ea 3
(b) Install ea 3
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 3
(b) Install ea 3
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 65
(b) Install m 65
Subtotal Carried To The Next Page
22
Subtotal From The Previous Page
ROOF
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 20
(b) Install m 20
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 2
(b) Install ea 2
3 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 2
(b) Install ea 2
4
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round
boxes, end boxes and suspension material to make
the installation complete
(a) Supply m 5
(b) Install m 5
Total amount carried forward to summary page
23
7 BUILDING 8
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets, fitting
screws, mounting bases and accessories to complete the
installation.
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 65
(b) Install m 65
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 6
(b) Install ea 6
3 Analogue Addressable Manual Call Points
(a) Supply ea 3
(b) Install ea 3
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 3
(b) Install ea 3
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
8 Network Card
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
24
Subtotal From The Previous Page
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
11
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
12
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 65
(b) Install m 65
BASEMENT
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 20
(b) Install m 20
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 2
(b) Install ea 2
3 Analogue Addressable Manual Call Points
(a) Supply ea 1
(b) Install ea 1
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
25
Subtotal From The Previous Page
5
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round boxes,
end boxes and suspension material to make the
installation complete
(a) Supply m 10
(b) Install m 10
FIRST FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 70
(b) Install m 70
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 10
(b) Install ea 10
3 Analogue Addressable Manual Call Points
(a) Supply ea 3
(b) Install ea 3
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 3
(b) Install ea 3
5
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round boxes,
end boxes and suspension material to make the
installation complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation
complete
(a) Supply m 70
(b) Install m 70
Subtotal Carried To The Next Page
26
Subtotal From The Previous Page
SECOND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 70
(b) Install m 70
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 11
(b) Install ea 11
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 3
(b) Install ea 3
5
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round boxes,
end boxes and suspension material to make the
installation complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation
complete
(a) Supply m 70
(b) Install m 70
Subtotal Carried To The Next Page
27
Subtotal From The Previous Page
THIRD FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 10
(b) Install m 10
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 1
(b) Install ea 1
3 Analogue Addressable Manual Call Points
(a) Supply ea 1
(b) Install ea 1
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 1
(b) Install ea 1
5
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round boxes,
end boxes and suspension material to make the
installation complete
(a) Supply m 5
(b) Install m 5
Total amount carried forward to summary page
28
8 BUILDING 10
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets, fitting
screws, mounting bases and accessories to complete the
installation.
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 410
(b) Install m 410
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 42
(b) Install ea 42
3 Analogue Addressable Manual Call Points
(a) Supply ea 10
(b) Install ea 10
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 14
(b) Install ea 14
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
8 Network Card
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
29
Subtotal From The Previous Page
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
11
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
12
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 410
(b) Install m 410
BASEMENT
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 290
(b) Install m 290
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 31
(b) Install ea 31
3 Analogue Addressable Manual Call Points
(a) Supply ea 7
(b) Install ea 7
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 8
(b) Install ea 8
Subtotal Carried To The Next Page
30
Subtotal From The Previous Page
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 290
(b) Install m 290
FIRST FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 370
(b) Install m 370
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 35
(b) Install ea 35
3 Analogue Addressable Manual Call Points
(a) Supply ea 9
(b) Install ea 9
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 13
(b) Install ea 13
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
Subtotal Carried To The Next Page
31
Subtotal From The Previous Page
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 370
(b) Install m 370
SECOND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 10
(b) Install m 10
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 1
(b) Install ea 1
3 Analogue Addressable Manual Call Points
(a) Supply ea 0
(b) Install ea 0
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 1
(b) Install ea 1
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 10
(b) Install m 10
Total amount carried forward to summary page
32
9 BUILDING 16
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets,
fitting screws, mounting bases and accessories to
complete the installation.
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 95
(b) Install m 95
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 9
(b) Install ea 9
3 Analogue Addressable Manual Call Points
(a) Supply ea 6
(b) Install ea 6
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 4
(b) Install ea 4
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
8 Network Card
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
33
Subtotal From The Previous Page
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
11
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round
boxes, end boxes and suspension material to make
the installation complete
(a) Supply m 5
(b) Install m 5
12
P8100 trunking inclusive of all suspension
brackets, bolts, screws, nuts, bends, T-pieces,
joints, covers and suspension material to make the
installation complete
(a) Supply m 95
(b) Install m 95
FIRST FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 110
(b) Install m 110
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 12
(b) Install ea 12
3 Analogue Addressable Manual Call Points
(a) Supply ea 4
(b) Install ea 4
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 4
(b) Install ea 4
Subtotal Carried To The Next Page
34
Subtotal From The Previous Page
5
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round
boxes, end boxes and suspension material to make
the installation complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers
and suspension material to make the installation
complete
(a) Supply m 110
(b) Install m 110
Total amount carried forward to summary page
35
10 BUILDING 22
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets, fitting
screws, mounting bases and accessories to complete the
installation.
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 180
(b) Install m 180
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 21
(b) Install ea 21
3 Analogue Addressable Manual Call Points
(a) Supply ea 5
(b) Install ea 5
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 6
(b) Install ea 6
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
8 Network Card
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
36
Subtotal From The Previous Page
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
11
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 10
11
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 180
(b) Install m 180
BASEMENT
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 10
(b) Install m 10
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 2
(b) Install ea 2
3 Analogue Addressable Manual Call Points
(a) Supply ea 1
(b) Install ea 1
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
37
Subtotal From The Previous Page
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 10
(b) Install m 10
FIRST FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 80
(b) Install m 80
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 11
(b) Install ea 11
3 Analogue Addressable Manual Call Points
(a) Supply ea 4
(b) Install ea 4
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 4
(b) Install ea 4
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 80
(b) Install m 80
Subtotal Carried To The Next Page
38
Subtotal From The Previous Page
SECOND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 50
(b) Install m 50
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 7
(b) Install ea 7
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 2
(b) Install ea 2
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 50
(b) Install m 50
THIRD FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 50
(b) Install m 50
Subtotal Carried To The Next Page
39
Subtotal From The Previous Page
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 8
(b) Install ea 8
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 3
(b) Install ea 3
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 50
(b) Install m 50
FOURTH FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 50
(b) Install m 50
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 7
(b) Install ea 7
Subtotal Carried To The Next Page
40
Subtotal From The Previous Page
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 2
(b) Install ea 2
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 50
(b) Install m 50
FIFTH FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 10
(b) Install m 10
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 2
(b) Install ea 2
3 Analogue Addressable Manual Call Points
(a) Supply ea 1
(b) Install ea 1
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
41
Subtotal From The Previous Page
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 10
(b) Install m 10
SIXTH FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 10
(b) Install m 10
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 1
(b) Install ea 1
3 Analogue Addressable Manual Call Points
(a) Supply ea 1
(b) Install ea 1
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 1
(b) Install ea 1
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 10
(b) Install m 10
Total amount carried forward to summary page
42
11 BUILDING 23
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets, fitting
screws, mounting bases and accessories to complete the
installation.
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 150
(b) Install m 150
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 15
(b) Install ea 15
3 Analogue Addressable Manual Call Points
(a) Supply ea 6
(b) Install ea 6
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 6
(b) Install ea 6
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
8 Network Card
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
43
Subtotal From The Previous Page
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
11
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 5
(b) Install m 5
12
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 150
(b) Install m 150
BASEMENT
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 10
(b) Install m 10
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 1
(b) Install ea 1
3 Analogue Addressable Manual Call Points
(a) Supply ea 0
(b) Install ea 0
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
44
Subtotal From The Previous Page
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 10
(b) Install m 10
FIRST FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 150
(b) Install m 150
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 17
(b) Install ea 17
3 Analogue Addressable Manual Call Points
(a) Supply ea 5
(b) Install ea 5
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 7
(b) Install ea 7
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 150
(b) Install m 150
Subtotal Carried To The Next Page
45
Subtotal From The Previous Page
SECOND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 10
(b) Install m 10
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 1
(b) Install ea 1
3 Analogue Addressable Manual Call Points
(a) Supply ea 0
(b) Install ea 0
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 1
(b) Install ea 1
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 10
(b) Install m 10
THIRD FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 25
(b) Install m 25
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 2
(b) Install ea 2
3 Analogue Addressable Manual Call Points
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
46
Subtotal From The Previous Page
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 2
(b) Install ea 2
17
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 25
(b) Install m 25
FOURTH FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 10
(b) Install m 10
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 1
(b) Install ea 1
3 Analogue Addressable Manual Call Points
(a) Supply ea 1
(b) Install ea 1
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 1
(b) Install ea 1
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 10
(b) Install m 10
Total amount carried forward to summary page
47
12 BUILDING 34
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets,
fitting screws, mounting bases and accessories to
complete the installation.
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 70
(b) Install m 70
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 9
(b) Install ea 9
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 4
(b) Install ea 4
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
8 Network Card
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
48
Subtotal From The Previous Page
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
11
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round
boxes, end boxes and suspension material to make
the installation complete
(a) Supply m 5
(b) Install m 5
12
P8100 trunking inclusive of all suspension
brackets, bolts, screws, nuts, bends, T-pieces,
joints, covers and suspension material to make the
installation complete
(a) Supply m 70
(b) Install m 70
FIRST FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 70
(b) Install m 70
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 7
(b) Install ea 7
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 3
(b) Install ea 3
Subtotal Carried To The Next Page
49
Subtotal From The Previous Page
5
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round
boxes, end boxes and suspension material to make
the installation complete
(a) Supply m 10
(b) Install m 10
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers
and suspension material to make the installation
complete
(a) Supply m 70
(b) Install m 70
LOWER GROUND
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 10
(b) Install m 10
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 2
(b) Install ea 2
3 Analogue Addressable Manual Call Points
(a) Supply ea 1
(b) Install ea 1
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 1
(b) Install ea 1
5
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round
boxes, end boxes and suspension material to make
the installation complete
(a) Supply m 10
(b) Install m 10
Total amount carried forward to summary page
50
13 BUILDING 35
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets,
fitting screws, mounting bases and accessories to
complete the installation.
LOWER GROUND
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 40
(b) Install m 40
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 5
(b) Install ea 5
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 2
(b) Install ea 2
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
8 Network Card
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
51
Subtotal From The Previous Page
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
11
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
12
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 40
(b) Install m 40
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 130
(b) Install m 130
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 11
(b) Install ea 11
3 Analogue Addressable Manual Call Points
(a) Supply ea 4
(b) Install ea 4
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 4
(b) Install ea 4
Subtotal Carried To The Next Page
52
Subtotal From The Previous Page
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 130
(b) Install m 130
Total amount carried forward to summary page
53
14 BUILDING 36
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets,
fitting screws, mounting bases and accessories to
complete the installation.
LOWER GROUND
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 70
(b) Install m 70
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 6
(b) Install ea 6
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 4
(b) Install ea 4
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
8 Network Card
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
54
Subtotal From The Previous Page
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
11
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round
boxes, end boxes and suspension material to make
the installation complete
(a) Supply m 5
(b) Install m 5
12
P8100 trunking inclusive of all suspension
brackets, bolts, screws, nuts, bends, T-pieces,
joints, covers and suspension material to make the
installation complete
(a) Supply m 70
(b) Install m 70
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 70
(b) Install m 70
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 6
(b) Install ea 6
3 Analogue Addressable Manual Call Points
(a) Supply ea 3
(b) Install ea 3
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 3
(b) Install ea 3
Subtotal Carried To The Next Page
55
Subtotal From The Previous Page
5
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round
boxes, end boxes and suspension material to make
the installation complete
(a) Supply m 5 R 76,00
(b) Install m 5 R 19,20
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers
and suspension material to make the installation
complete
(a) Supply m 70 R 140,00
(b) Install m 70 R 56,00
Total amount carried forward to summary page
56
15 BUILDING 40
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets,
fitting screws, mounting bases and accessories to
complete the installation.
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 70
(b) Install m 70
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 7
(b) Install ea 7
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 2
(b) Install ea 2
5 Analogue Addressable Loop Isolators
(a) Supply ea 0
(b) Install ea 0
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
8 Network Card
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
57
Subtotal From The Previous Page
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
11
Ø20mm galvanized conduit inclusive of all
suspension brackets, bolts, screws, nuts, round
boxes, end boxes and suspension material to make
the installation complete
(a) Supply m 5
(b) Install m 5
12
P8100 trunking inclusive of all suspension
brackets, bolts, screws, nuts, bends, T-pieces,
joints, covers and suspension material to make the
installation complete
(a) Supply m 70
(b) Install m 70
Total amount carried forward to summary page
58
16 BUILDING 41
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets, fitting
screws, mounting bases and accessories to complete the
installation.
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 65
(b) Install m 65
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 8
(b) Install ea 8
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 3
(b) Install ea 3
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
8 Network Card
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
59
Subtotal From The Previous Page
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
11
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 5
(b) Install m 5
12
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 65
(b) Install m 65
BASEMENT
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 16
(b) Install m 16
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 2
(b) Install ea 2
3 Analogue Addressable Manual Call Points
(a) Supply ea 1
(b) Install ea 1
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
60
Subtotal From The Previous Page
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 16
(b) Install m 16
FIRST FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 65
(b) Install m 65
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 6
(b) Install ea 6
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 3
(b) Install ea 3
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 65
(b) Install m 65
Subtotal Carried To The Next Page
61
Subtotal From The Previous Page
SECOND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 65
(b) Install m 65
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 6
(b) Install ea 6
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 3
(b) Install ea 3
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 65
(b) Install m 65
THIRD FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 70
(b) Install m 70
Subtotal Carried To The Next Page
62
Subtotal From The Previous Page
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 6
(b) Install ea 6
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 3
(b) Install ea 3
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 70
(b) Install m 70
FOURTH FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 10
(b) Install m 10
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 1
(b) Install ea 1
3 Analogue Addressable Manual Call Points
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
63
Subtotal From The Previous Page
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 1
(b) Install ea 1
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 10
(b) Install m 10
Total amount carried forward to summary page
64
17 BUILDING 42
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets, fitting
screws, mounting bases and accessories to complete the
installation.
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 80
(b) Install m 80
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 12
(b) Install ea 12
3 Analogue Addressable Manual Call Points
(a) Supply ea 3
(b) Install ea 3
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 4
(b) Install ea 4
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
8 Network Card
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
65
Subtotal From The Previous Page
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
11
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
12
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 80
(b) Install m 80
BASEMENT
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 20
(b) Install m 20
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 4
(b) Install ea 4
3 Analogue Addressable Manual Call Points
(a) Supply ea 2
(b) Install ea 2
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
66
Subtotal From The Previous Page
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 20
(b) Install m 20
FIRST FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 80
(b) Install m 80
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 8
(b) Install ea 8
3 Analogue Addressable Manual Call Points
(a) Supply ea 3
(b) Install ea 3
4 Analogue Addressable Loop Powered Beacon
Sounders
(a) Supply ea 2
(b) Install ea 2
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 10
(b) Install m 10
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 50
(b) Install m 50
Subtotal Carried To The Next Page
67
Subtotal From The Previous Page
SECOND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 10
(b) Install m 10
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 1
(b) Install ea 1
3 Analogue Addressable Manual Call Points
(a) Supply ea 1
(b) Install ea 1
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 1
(b) Install ea 1
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
Total amount carried forward to summary page
68
18 BUILDING 46
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
All equipment as specified, complete with brackets, fitting
screws, mounting bases and accessories to complete the
installation.
GROUND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 130
(b) Install m 130
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 15
(b) Install ea 15
3 Analogue Addressable Manual Call Points
(a) Supply ea 5
(b) Install ea 5
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 5
(b) Install ea 5
5 Analogue Addressable Loop Isolators
(a) Supply ea 1
(b) Install ea 1
6 2-Loop Analogue addressable Fire Alarm Panel
(a) Supply ea 1
(b) Install ea 1
7 26Ah Battery 12V dc
(a) Supply ea 1
(b) Install ea 1
8 Network Card
(a) Supply ea 1
(b) Install ea 1
Subtotal Carried To The Next Page
69
Subtotal From The Previous Page
9 System Configuration and Testing Sum 1
10 Signage
Provide zone diagram and associated signage. Sum 1
11
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 5
(b) Install m 5
12
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 130
(b) Install m 130
FIRST FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 110
(b) Install m 110
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 13
(b) Install ea 13
3 Analogue Addressable Manual Call Points
(a) Supply ea 5
(b) Install ea 5
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 3
(b) Install ea 3
Subtotal Carried To The Next Page
70
Subtotal From The Previous Page
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 105
(b) Install m 105
SECOND FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 130
(b) Install m 130
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 14
(b) Install ea 14
3 Analogue Addressable Manual Call Points
(a) Supply ea 4
(b) Install ea 4
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 3
(b) Install ea 3
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes and
suspension material to make the installation complete
(a) Supply m 5
(b) Install m 5
Subtotal Carried To The Next Page
71
Subtotal From The Previous Page
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 130
(b) Install m 130
THIRD FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 100
(b) Install m 100
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 12
(b) Install ea 12
3 Analogue Addressable Manual Call Points
(a) Supply ea 3
(b) Install ea 3
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 4
(b) Install ea 4
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 5
(b) Install m 5
6
P8100 trunking inclusive of all suspension brackets,
bolts, screws, nuts, bends, T-pieces, joints, covers and
suspension material to make the installation complete
(a) Supply m 100
(b) Install m 100
Subtotal Carried To The Next Page
72
Subtotal From The Previous Page
FOURTH FLOOR
1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes
(a) Supply m 10
(b) Install m 10
2 Analogue Addressable Optical Smoke Detectors
(a) Supply ea 1
(b) Install ea 1
3 Analogue Addressable Manual Call Points
(a) Supply ea 1
(b) Install ea 1
4 Analogue Addressable Loop Powered Beacon Sounders
(a) Supply ea 1
(b) Install ea 1
5
Ø20mm galvanized conduit inclusive of all suspension
brackets, bolts, screws, nuts, round boxes, end boxes
and suspension material to make the installation
complete
(a) Supply m 10
(b) Install m 10
Total amount carried forward to summary page
73
19 MISCELLANEOUS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1 Training of Client’s staff ea 10
2
3 x Full sets of operating and maintenance
manuals Sum 1
3 3 x sets of As built drawings Sum 1
(Drawings to show the exact positions of conduits,
trunking, field devices, System schematic, e.t.c.to
be issued in Hard copies and CDs)
4 Core Drill between floors ea 20
5 Fire Seal around Core Drill between floors ea 20
6
Scheduled Preventative Maintenance for the
entire Installations on a monthly basis during
the guarantee / warrantee period. Month
12
Total amount carried forward to summary page
74
20 SUMMARY
SUMMARY (CSIR - FIRE DETECTION)
1 PRELIMINARIES AND GENERALS
2 BUILDING 1
3 BUILDING 2
4 BUILDING 3
5 BUILDING 4
6 BUILDING 8
7 BUILDING 10
8 BUILDING 16
9 BUILDING 22
10 BUILDING 23
11 BUILDING 34
12 BUILDING 35
13 BUILDING 36
15 BUILDING 40
16 BUILDING 41
17 BUILDING 42
18 BUILDING 46
19 MISCELLANEOUS
SUB-TOTAL
CONTINGENCIES AT (10%)
SUB-TOTAL INCLUDING CONTINGENCIES (10%)
VALUE ADDED TAX AT 15%
TOTAL INCLUDING VAT AT 15%