74
ANNEXURE D: BILLS OF QUANTITIES

ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

ANNEXURE D: BILLS OF QUANTITIES

Page 2: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

2

TABLE OF CONTENTS

1 GENERAL .................................................................................................................................................. 3

2 PRELIMINARIES & GENERALS ............................................................................................................. 4

3 BUILDING 1 ............................................................................................................................................... 5

4 BUILDING 2 ............................................................................................................................................... 7

5 BUILDING 3 ............................................................................................................................................. 12

6 BUILDING 4 ............................................................................................................................................. 16

7 BUILDING 8 ............................................................................................................................................. 23

8 BUILDING 10 ........................................................................................................................................... 28

9 BUILDING 16 ........................................................................................................................................... 32

10 BUILDING 22 ....................................................................................................................................... 35

11 BUILDING 23 ....................................................................................................................................... 42

12 BUILDING 34 ....................................................................................................................................... 47

13 BUILDING 35 ....................................................................................................................................... 50

14 BUILDING 36 ....................................................................................................................................... 53

15 BUILDING 40 ....................................................................................................................................... 56

16 BUILDING 41 ....................................................................................................................................... 58

17 BUILDING 42 ....................................................................................................................................... 64

18 BUILDING 46 ....................................................................................................................................... 68

19 MISCELLANEOUS .............................................................................................................................. 73

20 SUMMARY ........................................................................................................................................... 74

Page 3: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

3

1 GENERAL

The tenderers must complete the Bills of Quantities and detail unit rates and total amount for each item. All

rates and prices exclude VAT.

NOTE:

Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring in the

priced Bills of Quantities cannot be considered as having an effect on the tender amount.

No alteration, erasure or addition is to be made in the text of the Bills of Quantities. Should any alteration,

erasure or addition be made it will not be recognized but the original wording of the Bills of Quantities will

be adhered to.

The Employer will check the completed Bills of Quantities and reserves the right to adjust any individual

price and to rectify and discrepancy whilst the total tender price as quoted remains unaltered.

The quantities given in the Bills for video cables, power cables, cable markers, and data cables cannot be

regarded as exact and are subject to measurement on site after completion of the installation and adjustments

will be made according to the unit rates given in the Bills.

The quantities given in the Bill of Quantities are estimates only, and subject to re-measuring during the

execution of the work. The Contractor shall obtain the Engineer’s detailed instructions for all work before

ordering any materials or executing work or making arrangement for it.

The Works as finally completed in accordance with the Contract shall be measured and paid for as specified

in the Bill of Quantities and in accordance with the General and Special Conditions of Contract, the

Specifications and Project Specifications and the Drawings. Unless otherwise stated, items are measured net

in accordance with the Drawings, and no allowance has been made for waste.

The validity of the contract will in no way be affected by differences between the quantities in the Bill of

Quantities and the quantities finally certified for payment.

Page 4: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

4

2 PRELIMINARIES & GENERALS

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

1 General

Allow for complying with all special preliminary

and general conditions and contract and labour

requirements, for site establishment and providing

a site office Sum 1

2 Permits and notices

Allow for coordination with other contractors Sum 0

3 Storage

Provide for storage of plant, materials and

equipment on site including protection thereof Sum 1

5 Transport

Transport of material shall include delivery costs Sum 1

6 OHS file Sum 1

7 After Hours / Weekend Work Hrs 80

Total amount carried forward to summary page

Page 5: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

5

3 BUILDING 1

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets,

fitting screws, mounting bases and accessories to

complete the installation.

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 50

(b) Install m 50

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 3

(b) Install ea 3

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 2

(b) Install ea 2

5 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

6 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

7 Network Card

(a) Supply ea 1

(b) Install ea 1

8 System Configuration and Testing Sum 1

Subtotal Carried To The Next Page

Page 6: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

6

Subtotal From The Previous Page

9 Signage

Provide zone diagram and associated signage. Sum 1

10

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round boxes,

end boxes and suspension material to make the

installation complete

(a) Supply m 10

(b) Install m 10

11

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 50

(b) Install m 50

Total amount carried forward to summary page

Page 7: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

7

4 BUILDING 2

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets,

fitting screws, mounting bases and accessories to

complete the installation.

BASEMENT

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 120

(b) Install m 120

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 13

(b) Install ea 13

3 Analogue Addressable Manual Call Points

(a) Supply ea 3

(b) Install ea 3

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 6

(b) Install ea 6

5

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round boxes,

end boxes and suspension material to make the

installation complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation

complete

(a) Supply m 120

(b) Install m 120

Subtotal Carried To The Next Page

Page 8: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

8

Subtotal From The Previous Page

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 270

(b) Install m 270

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 30

(b) Install ea 30

3 Analogue Addressable Manual Call Points

(a) Supply ea 10

(b) Install ea 10

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 9

(b) Install ea 9

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 Network Card

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 9: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

9

Subtotal From The Previous Page

8 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

11

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 20

(b) Install m 20

12

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 270

(b) Install m 270

FIRST FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 290

(b) Install m 290

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 34

(b) Install ea 34

3 Analogue Addressable Manual Call Points

(a) Supply ea 11

(b) Install ea 11

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 9

(b) Install ea 9

Subtotal Carried To The Next Page

Page 10: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

10

Subtotal From The Previous Page

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 20

(b) Install m 20

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 290

(b) Install m 290

SECOND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 270

(b) Install m 270

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 28

(b) Install ea 28

3 Analogue Addressable Manual Call Points

(a) Supply ea 7

(b) Install ea 7

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 10

(b) Install ea 10

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 10

(b) Install m 10

Subtotal Carried To The Next Page

Page 11: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

11

Subtotal From The Previous Page

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 270

(b) Install m 270

THIRD FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 140

(b) Install m 170

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 14

(b) Install ea 14

3 Analogue Addressable Manual Call Points

(a) Supply ea 5

(b) Install ea 5

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 6

(b) Install ea 6

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 140

(b) Install m 140

Total amount carried forward to summary page

Page 12: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

12

5 BUILDING 3

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets,

fitting screws, mounting bases and accessories to

complete the installation.

BASEMENT

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 65

(b) Install m 65

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 7

(b) Install ea 7

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 2

(b) Install ea 2

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 65

(b) Install m 65

Subtotal Carried To The Next Page

Page 13: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

13

Subtotal From The Previous Page

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 140

(b) Install m 140

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 15

(b) Install ea 15

3 Analogue Addressable Manual Call Points

(a) Supply ea 6

(b) Install ea 6

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 5

(b) Install ea 5

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 Network Card

(a) Supply ea 1

(b) Install ea 1

8 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

Subtotal Carried To The Next Page

Page 14: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

14

Subtotal From The Previous Page

11

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

12

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 140

(b) Install m 140

FIRST FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 225

(b) Install m 225

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 26

(b) Install ea 26

3 Analogue Addressable Manual Call Points

(a) Supply ea 9

(b) Install ea 9

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 6

(b) Install ea 6

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

Subtotal Carried To The Next Page

Page 15: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

15

Subtotal From The Previous Page

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 225

(b) Install m 225

SECOND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 230

(b) Install m 230

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 26

(b) Install ea 26

3 Analogue Addressable Manual Call Points

(a) Supply ea 8

(b) Install ea 8

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 7

(b) Install ea 7

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 230

(b) Install m 230

Total amount carried forward to summary page

Page 16: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

16

6 BUILDING 4

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets, fitting

screws, mounting bases and accessories to complete the

installation.

LOWER GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 65

(b) Install m 65

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 8

(b) Install ea 8

3 Analogue Addressable Manual Call Points

(a) Supply ea 3

(b) Install ea 3

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 4

(b) Install ea 4

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 65

(b) Install m 65

Subtotal Carried To The Next Page

Page 17: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

17

Subtotal From The Previous Page

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 85

(b) Install m 85

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 9

(b) Install ea 9

3 Analogue Addressable Manual Call Points

(a) Supply ea 4

(b) Install ea 4

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 4

(b) Install ea 4

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

8 Network Card

(a) Supply ea 1

(b) Install ea 1

9 System Configuration and Testing Sum 1

Subtotal Carried To The Next Page

Page 18: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

18

Subtotal From The Previous Page

11

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

12

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 85

(b) Install m 85

FIRST FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 230

(b) Install m 230

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 26

(b) Install ea 26

3 Analogue Addressable Manual Call Points

(a) Supply ea 8

(b) Install ea 8

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 9

(b) Install ea 9

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

Subtotal Carried To The Next Page

Page 19: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

19

Subtotal From The Previous Page

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 230

(b) Install m 230

SECOND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 220

(b) Install m 220

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 26

(b) Install ea 26

3 Analogue Addressable Manual Call Points

(a) Supply ea 8

(b) Install ea 8

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 9

(b) Install ea 9

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 220

(b) Install m 220

Subtotal Carried To The Next Page

Page 20: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

20

Subtotal From The Previous Page

THIRD FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 160

(b) Install m 160

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 20

(b) Install ea 20

3 Analogue Addressable Manual Call Points

(a) Supply ea 6

(b) Install ea 6

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 6

(b) Install ea 6

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 160

(b) Install m 160

FOURTH FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 65

(b) Install m 65

Subtotal Carried To The Next Page

Page 21: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

21

Subtotal From The Previous Page

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 7

(b) Install ea 7

3 Analogue Addressable Manual Call Points

(a) Supply ea 3

(b) Install ea 3

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 3

(b) Install ea 3

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 65

(b) Install m 65

Subtotal Carried To The Next Page

Page 22: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

22

Subtotal From The Previous Page

ROOF

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 20

(b) Install m 20

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 2

(b) Install ea 2

3 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 2

(b) Install ea 2

4

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round

boxes, end boxes and suspension material to make

the installation complete

(a) Supply m 5

(b) Install m 5

Total amount carried forward to summary page

Page 23: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

23

7 BUILDING 8

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets, fitting

screws, mounting bases and accessories to complete the

installation.

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 65

(b) Install m 65

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 6

(b) Install ea 6

3 Analogue Addressable Manual Call Points

(a) Supply ea 3

(b) Install ea 3

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 3

(b) Install ea 3

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

8 Network Card

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 24: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

24

Subtotal From The Previous Page

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

11

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

12

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 65

(b) Install m 65

BASEMENT

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 20

(b) Install m 20

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 2

(b) Install ea 2

3 Analogue Addressable Manual Call Points

(a) Supply ea 1

(b) Install ea 1

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 25: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

25

Subtotal From The Previous Page

5

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round boxes,

end boxes and suspension material to make the

installation complete

(a) Supply m 10

(b) Install m 10

FIRST FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 70

(b) Install m 70

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 10

(b) Install ea 10

3 Analogue Addressable Manual Call Points

(a) Supply ea 3

(b) Install ea 3

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 3

(b) Install ea 3

5

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round boxes,

end boxes and suspension material to make the

installation complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation

complete

(a) Supply m 70

(b) Install m 70

Subtotal Carried To The Next Page

Page 26: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

26

Subtotal From The Previous Page

SECOND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 70

(b) Install m 70

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 11

(b) Install ea 11

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 3

(b) Install ea 3

5

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round boxes,

end boxes and suspension material to make the

installation complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation

complete

(a) Supply m 70

(b) Install m 70

Subtotal Carried To The Next Page

Page 27: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

27

Subtotal From The Previous Page

THIRD FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 10

(b) Install m 10

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 1

(b) Install ea 1

3 Analogue Addressable Manual Call Points

(a) Supply ea 1

(b) Install ea 1

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 1

(b) Install ea 1

5

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round boxes,

end boxes and suspension material to make the

installation complete

(a) Supply m 5

(b) Install m 5

Total amount carried forward to summary page

Page 28: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

28

8 BUILDING 10

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets, fitting

screws, mounting bases and accessories to complete the

installation.

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 410

(b) Install m 410

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 42

(b) Install ea 42

3 Analogue Addressable Manual Call Points

(a) Supply ea 10

(b) Install ea 10

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 14

(b) Install ea 14

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

8 Network Card

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 29: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

29

Subtotal From The Previous Page

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

11

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

12

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 410

(b) Install m 410

BASEMENT

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 290

(b) Install m 290

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 31

(b) Install ea 31

3 Analogue Addressable Manual Call Points

(a) Supply ea 7

(b) Install ea 7

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 8

(b) Install ea 8

Subtotal Carried To The Next Page

Page 30: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

30

Subtotal From The Previous Page

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 290

(b) Install m 290

FIRST FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 370

(b) Install m 370

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 35

(b) Install ea 35

3 Analogue Addressable Manual Call Points

(a) Supply ea 9

(b) Install ea 9

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 13

(b) Install ea 13

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

Subtotal Carried To The Next Page

Page 31: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

31

Subtotal From The Previous Page

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 370

(b) Install m 370

SECOND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 10

(b) Install m 10

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 1

(b) Install ea 1

3 Analogue Addressable Manual Call Points

(a) Supply ea 0

(b) Install ea 0

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 1

(b) Install ea 1

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 10

(b) Install m 10

Total amount carried forward to summary page

Page 32: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

32

9 BUILDING 16

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets,

fitting screws, mounting bases and accessories to

complete the installation.

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 95

(b) Install m 95

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 9

(b) Install ea 9

3 Analogue Addressable Manual Call Points

(a) Supply ea 6

(b) Install ea 6

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 4

(b) Install ea 4

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

8 Network Card

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 33: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

33

Subtotal From The Previous Page

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

11

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round

boxes, end boxes and suspension material to make

the installation complete

(a) Supply m 5

(b) Install m 5

12

P8100 trunking inclusive of all suspension

brackets, bolts, screws, nuts, bends, T-pieces,

joints, covers and suspension material to make the

installation complete

(a) Supply m 95

(b) Install m 95

FIRST FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 110

(b) Install m 110

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 12

(b) Install ea 12

3 Analogue Addressable Manual Call Points

(a) Supply ea 4

(b) Install ea 4

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 4

(b) Install ea 4

Subtotal Carried To The Next Page

Page 34: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

34

Subtotal From The Previous Page

5

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round

boxes, end boxes and suspension material to make

the installation complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers

and suspension material to make the installation

complete

(a) Supply m 110

(b) Install m 110

Total amount carried forward to summary page

Page 35: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

35

10 BUILDING 22

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets, fitting

screws, mounting bases and accessories to complete the

installation.

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 180

(b) Install m 180

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 21

(b) Install ea 21

3 Analogue Addressable Manual Call Points

(a) Supply ea 5

(b) Install ea 5

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 6

(b) Install ea 6

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

8 Network Card

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 36: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

36

Subtotal From The Previous Page

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

11

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 10

11

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 180

(b) Install m 180

BASEMENT

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 10

(b) Install m 10

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 2

(b) Install ea 2

3 Analogue Addressable Manual Call Points

(a) Supply ea 1

(b) Install ea 1

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 37: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

37

Subtotal From The Previous Page

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 10

(b) Install m 10

FIRST FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 80

(b) Install m 80

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 11

(b) Install ea 11

3 Analogue Addressable Manual Call Points

(a) Supply ea 4

(b) Install ea 4

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 4

(b) Install ea 4

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 80

(b) Install m 80

Subtotal Carried To The Next Page

Page 38: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

38

Subtotal From The Previous Page

SECOND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 50

(b) Install m 50

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 7

(b) Install ea 7

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 2

(b) Install ea 2

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 50

(b) Install m 50

THIRD FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 50

(b) Install m 50

Subtotal Carried To The Next Page

Page 39: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

39

Subtotal From The Previous Page

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 8

(b) Install ea 8

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 3

(b) Install ea 3

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 50

(b) Install m 50

FOURTH FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 50

(b) Install m 50

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 7

(b) Install ea 7

Subtotal Carried To The Next Page

Page 40: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

40

Subtotal From The Previous Page

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 2

(b) Install ea 2

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 50

(b) Install m 50

FIFTH FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 10

(b) Install m 10

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 2

(b) Install ea 2

3 Analogue Addressable Manual Call Points

(a) Supply ea 1

(b) Install ea 1

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 41: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

41

Subtotal From The Previous Page

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 10

(b) Install m 10

SIXTH FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 10

(b) Install m 10

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 1

(b) Install ea 1

3 Analogue Addressable Manual Call Points

(a) Supply ea 1

(b) Install ea 1

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 1

(b) Install ea 1

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 10

(b) Install m 10

Total amount carried forward to summary page

Page 42: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

42

11 BUILDING 23

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets, fitting

screws, mounting bases and accessories to complete the

installation.

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 150

(b) Install m 150

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 15

(b) Install ea 15

3 Analogue Addressable Manual Call Points

(a) Supply ea 6

(b) Install ea 6

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 6

(b) Install ea 6

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

8 Network Card

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 43: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

43

Subtotal From The Previous Page

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

11

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 5

(b) Install m 5

12

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 150

(b) Install m 150

BASEMENT

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 10

(b) Install m 10

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 1

(b) Install ea 1

3 Analogue Addressable Manual Call Points

(a) Supply ea 0

(b) Install ea 0

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 44: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

44

Subtotal From The Previous Page

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 10

(b) Install m 10

FIRST FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 150

(b) Install m 150

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 17

(b) Install ea 17

3 Analogue Addressable Manual Call Points

(a) Supply ea 5

(b) Install ea 5

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 7

(b) Install ea 7

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 150

(b) Install m 150

Subtotal Carried To The Next Page

Page 45: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

45

Subtotal From The Previous Page

SECOND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 10

(b) Install m 10

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 1

(b) Install ea 1

3 Analogue Addressable Manual Call Points

(a) Supply ea 0

(b) Install ea 0

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 1

(b) Install ea 1

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 10

(b) Install m 10

THIRD FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 25

(b) Install m 25

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 2

(b) Install ea 2

3 Analogue Addressable Manual Call Points

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 46: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

46

Subtotal From The Previous Page

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 2

(b) Install ea 2

17

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 25

(b) Install m 25

FOURTH FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 10

(b) Install m 10

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 1

(b) Install ea 1

3 Analogue Addressable Manual Call Points

(a) Supply ea 1

(b) Install ea 1

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 1

(b) Install ea 1

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 10

(b) Install m 10

Total amount carried forward to summary page

Page 47: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

47

12 BUILDING 34

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets,

fitting screws, mounting bases and accessories to

complete the installation.

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 70

(b) Install m 70

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 9

(b) Install ea 9

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 4

(b) Install ea 4

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

8 Network Card

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 48: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

48

Subtotal From The Previous Page

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

11

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round

boxes, end boxes and suspension material to make

the installation complete

(a) Supply m 5

(b) Install m 5

12

P8100 trunking inclusive of all suspension

brackets, bolts, screws, nuts, bends, T-pieces,

joints, covers and suspension material to make the

installation complete

(a) Supply m 70

(b) Install m 70

FIRST FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 70

(b) Install m 70

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 7

(b) Install ea 7

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 3

(b) Install ea 3

Subtotal Carried To The Next Page

Page 49: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

49

Subtotal From The Previous Page

5

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round

boxes, end boxes and suspension material to make

the installation complete

(a) Supply m 10

(b) Install m 10

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers

and suspension material to make the installation

complete

(a) Supply m 70

(b) Install m 70

LOWER GROUND

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 10

(b) Install m 10

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 2

(b) Install ea 2

3 Analogue Addressable Manual Call Points

(a) Supply ea 1

(b) Install ea 1

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 1

(b) Install ea 1

5

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round

boxes, end boxes and suspension material to make

the installation complete

(a) Supply m 10

(b) Install m 10

Total amount carried forward to summary page

Page 50: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

50

13 BUILDING 35

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets,

fitting screws, mounting bases and accessories to

complete the installation.

LOWER GROUND

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 40

(b) Install m 40

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 5

(b) Install ea 5

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 2

(b) Install ea 2

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

8 Network Card

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 51: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

51

Subtotal From The Previous Page

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

11

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

12

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 40

(b) Install m 40

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 130

(b) Install m 130

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 11

(b) Install ea 11

3 Analogue Addressable Manual Call Points

(a) Supply ea 4

(b) Install ea 4

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 4

(b) Install ea 4

Subtotal Carried To The Next Page

Page 52: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

52

Subtotal From The Previous Page

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 130

(b) Install m 130

Total amount carried forward to summary page

Page 53: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

53

14 BUILDING 36

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets,

fitting screws, mounting bases and accessories to

complete the installation.

LOWER GROUND

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 70

(b) Install m 70

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 6

(b) Install ea 6

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 4

(b) Install ea 4

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

8 Network Card

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 54: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

54

Subtotal From The Previous Page

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

11

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round

boxes, end boxes and suspension material to make

the installation complete

(a) Supply m 5

(b) Install m 5

12

P8100 trunking inclusive of all suspension

brackets, bolts, screws, nuts, bends, T-pieces,

joints, covers and suspension material to make the

installation complete

(a) Supply m 70

(b) Install m 70

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 70

(b) Install m 70

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 6

(b) Install ea 6

3 Analogue Addressable Manual Call Points

(a) Supply ea 3

(b) Install ea 3

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 3

(b) Install ea 3

Subtotal Carried To The Next Page

Page 55: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

55

Subtotal From The Previous Page

5

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round

boxes, end boxes and suspension material to make

the installation complete

(a) Supply m 5 R 76,00

(b) Install m 5 R 19,20

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers

and suspension material to make the installation

complete

(a) Supply m 70 R 140,00

(b) Install m 70 R 56,00

Total amount carried forward to summary page

Page 56: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

56

15 BUILDING 40

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets,

fitting screws, mounting bases and accessories to

complete the installation.

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 70

(b) Install m 70

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 7

(b) Install ea 7

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 2

(b) Install ea 2

5 Analogue Addressable Loop Isolators

(a) Supply ea 0

(b) Install ea 0

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

8 Network Card

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 57: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

57

Subtotal From The Previous Page

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

11

Ø20mm galvanized conduit inclusive of all

suspension brackets, bolts, screws, nuts, round

boxes, end boxes and suspension material to make

the installation complete

(a) Supply m 5

(b) Install m 5

12

P8100 trunking inclusive of all suspension

brackets, bolts, screws, nuts, bends, T-pieces,

joints, covers and suspension material to make the

installation complete

(a) Supply m 70

(b) Install m 70

Total amount carried forward to summary page

Page 58: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

58

16 BUILDING 41

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets, fitting

screws, mounting bases and accessories to complete the

installation.

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 65

(b) Install m 65

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 8

(b) Install ea 8

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 3

(b) Install ea 3

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

8 Network Card

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 59: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

59

Subtotal From The Previous Page

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

11

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 5

(b) Install m 5

12

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 65

(b) Install m 65

BASEMENT

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 16

(b) Install m 16

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 2

(b) Install ea 2

3 Analogue Addressable Manual Call Points

(a) Supply ea 1

(b) Install ea 1

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 60: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

60

Subtotal From The Previous Page

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 16

(b) Install m 16

FIRST FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 65

(b) Install m 65

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 6

(b) Install ea 6

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 3

(b) Install ea 3

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 65

(b) Install m 65

Subtotal Carried To The Next Page

Page 61: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

61

Subtotal From The Previous Page

SECOND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 65

(b) Install m 65

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 6

(b) Install ea 6

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 3

(b) Install ea 3

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 65

(b) Install m 65

THIRD FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 70

(b) Install m 70

Subtotal Carried To The Next Page

Page 62: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

62

Subtotal From The Previous Page

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 6

(b) Install ea 6

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 3

(b) Install ea 3

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 70

(b) Install m 70

FOURTH FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 10

(b) Install m 10

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 1

(b) Install ea 1

3 Analogue Addressable Manual Call Points

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 63: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

63

Subtotal From The Previous Page

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 1

(b) Install ea 1

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 10

(b) Install m 10

Total amount carried forward to summary page

Page 64: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

64

17 BUILDING 42

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets, fitting

screws, mounting bases and accessories to complete the

installation.

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 80

(b) Install m 80

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 12

(b) Install ea 12

3 Analogue Addressable Manual Call Points

(a) Supply ea 3

(b) Install ea 3

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 4

(b) Install ea 4

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

8 Network Card

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 65: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

65

Subtotal From The Previous Page

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

11

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

12

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 80

(b) Install m 80

BASEMENT

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 20

(b) Install m 20

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 4

(b) Install ea 4

3 Analogue Addressable Manual Call Points

(a) Supply ea 2

(b) Install ea 2

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 66: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

66

Subtotal From The Previous Page

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 20

(b) Install m 20

FIRST FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 80

(b) Install m 80

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 8

(b) Install ea 8

3 Analogue Addressable Manual Call Points

(a) Supply ea 3

(b) Install ea 3

4 Analogue Addressable Loop Powered Beacon

Sounders

(a) Supply ea 2

(b) Install ea 2

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 10

(b) Install m 10

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 50

(b) Install m 50

Subtotal Carried To The Next Page

Page 67: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

67

Subtotal From The Previous Page

SECOND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 10

(b) Install m 10

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 1

(b) Install ea 1

3 Analogue Addressable Manual Call Points

(a) Supply ea 1

(b) Install ea 1

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 1

(b) Install ea 1

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

Total amount carried forward to summary page

Page 68: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

68

18 BUILDING 46

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

All equipment as specified, complete with brackets, fitting

screws, mounting bases and accessories to complete the

installation.

GROUND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 130

(b) Install m 130

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 15

(b) Install ea 15

3 Analogue Addressable Manual Call Points

(a) Supply ea 5

(b) Install ea 5

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 5

(b) Install ea 5

5 Analogue Addressable Loop Isolators

(a) Supply ea 1

(b) Install ea 1

6 2-Loop Analogue addressable Fire Alarm Panel

(a) Supply ea 1

(b) Install ea 1

7 26Ah Battery 12V dc

(a) Supply ea 1

(b) Install ea 1

8 Network Card

(a) Supply ea 1

(b) Install ea 1

Subtotal Carried To The Next Page

Page 69: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

69

Subtotal From The Previous Page

9 System Configuration and Testing Sum 1

10 Signage

Provide zone diagram and associated signage. Sum 1

11

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 5

(b) Install m 5

12

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 130

(b) Install m 130

FIRST FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 110

(b) Install m 110

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 13

(b) Install ea 13

3 Analogue Addressable Manual Call Points

(a) Supply ea 5

(b) Install ea 5

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 3

(b) Install ea 3

Subtotal Carried To The Next Page

Page 70: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

70

Subtotal From The Previous Page

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 105

(b) Install m 105

SECOND FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 130

(b) Install m 130

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 14

(b) Install ea 14

3 Analogue Addressable Manual Call Points

(a) Supply ea 4

(b) Install ea 4

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 3

(b) Install ea 3

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes and

suspension material to make the installation complete

(a) Supply m 5

(b) Install m 5

Subtotal Carried To The Next Page

Page 71: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

71

Subtotal From The Previous Page

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 130

(b) Install m 130

THIRD FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 100

(b) Install m 100

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 12

(b) Install ea 12

3 Analogue Addressable Manual Call Points

(a) Supply ea 3

(b) Install ea 3

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 4

(b) Install ea 4

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 5

(b) Install m 5

6

P8100 trunking inclusive of all suspension brackets,

bolts, screws, nuts, bends, T-pieces, joints, covers and

suspension material to make the installation complete

(a) Supply m 100

(b) Install m 100

Subtotal Carried To The Next Page

Page 72: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

72

Subtotal From The Previous Page

FOURTH FLOOR

1 PH30, Fire resistant 2 core cable 1.5mm² , 30 minutes

(a) Supply m 10

(b) Install m 10

2 Analogue Addressable Optical Smoke Detectors

(a) Supply ea 1

(b) Install ea 1

3 Analogue Addressable Manual Call Points

(a) Supply ea 1

(b) Install ea 1

4 Analogue Addressable Loop Powered Beacon Sounders

(a) Supply ea 1

(b) Install ea 1

5

Ø20mm galvanized conduit inclusive of all suspension

brackets, bolts, screws, nuts, round boxes, end boxes

and suspension material to make the installation

complete

(a) Supply m 10

(b) Install m 10

Total amount carried forward to summary page

Page 73: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

73

19 MISCELLANEOUS

ITEM DESCRIPTION UNIT QTY RATE AMOUNT

1 Training of Client’s staff ea 10

2

3 x Full sets of operating and maintenance

manuals Sum 1

3 3 x sets of As built drawings Sum 1

(Drawings to show the exact positions of conduits,

trunking, field devices, System schematic, e.t.c.to

be issued in Hard copies and CDs)

4 Core Drill between floors ea 20

5 Fire Seal around Core Drill between floors ea 20

6

Scheduled Preventative Maintenance for the

entire Installations on a monthly basis during

the guarantee / warrantee period. Month

12

Total amount carried forward to summary page

Page 74: ANNEXURE D: BILLS OF QUANTITIES D - … · rates and prices exclude VAT. NOTE: Tenderers are advised to check their item extensions and total additions as arithmetical errors occurring

74

20 SUMMARY

SUMMARY (CSIR - FIRE DETECTION)

1 PRELIMINARIES AND GENERALS

2 BUILDING 1

3 BUILDING 2

4 BUILDING 3

5 BUILDING 4

6 BUILDING 8

7 BUILDING 10

8 BUILDING 16

9 BUILDING 22

10 BUILDING 23

11 BUILDING 34

12 BUILDING 35

13 BUILDING 36

15 BUILDING 40

16 BUILDING 41

17 BUILDING 42

18 BUILDING 46

19 MISCELLANEOUS

SUB-TOTAL

CONTINGENCIES AT (10%)

SUB-TOTAL INCLUDING CONTINGENCIES (10%)

VALUE ADDED TAX AT 15%

TOTAL INCLUDING VAT AT 15%