  • APPENDIX J

  • CF-CO-LACEY-1 Rev. 5.0, 01/2018

    CERTIFICATE OF ORIGIN City of Lacey

    Engineered Wastewater Collection System

    Single Family Residence using 1500 or 1700 Gallon Tank

    Two Family Residence (Duplex) using 3000 Gallon Concrete Tank

    The following Collection System On-Lot Package is certified to have been manufactured by Orenco Systems®, Inc., Sutherlin, Oregon. The On-Lot Package equipment listed below is covered by an extended factory warranty under the terms and conditions of Orenco Systems’ Certificated Products Limited Warranty in effect at the time of sale.

    On-Lot Package Code: PSA10-S1DS-LACEY-WA

    Adhesive: ................................................................... (3) ADH100

    Splice Box: ................................................................ (1) SBEX1-4, (3)SBHSY, (5)SBHSB

    Biotube® Pump Vault: ................................................ (1) PVU57-1819-L

    Float Assembly: ......................................................... (1) MFPG-27V-LACEY

    Discharge Assembly: ................................................. (1) HV100BFCPR-80, (1) HVX100PR-80

    Effluent Pump: ........................................................... (1) PF100511, (1) PPSC-10

    Control Panel: ............................................................ (1) S1DS-LACEY

    Homeowner Manual: ................................................. (1) PMHOMEMANUAL

    Installation Manual: ................................................... (1) PMPSPPINST

    Certificate of Origin: .................................................. (1) NCF-CO-LACEY- 1

    Additional Orenco Equipment Required for a Complete Installation:

    PVC Access Risers & Accessories: .......................... (1) RR30XX+SX, (1)RLA30, (1) G1L, (1) RR24XX, (1) RLA,24

    Riser Adapters (Cast into Tank) ................................ (1) PRTA24, (1) PRTA30, (1) PRTA08

    Fiberglass Access Lids: ............................................. (1) FLF30G, (1) FLD24G, (1) FL8G

    Service Connection Valve Assembly ......................... (1) SC125-LACEY

    For Customer Use: Site address:

    Lot number:

    Development:

    Installer: Install Date:

    Vendor:

    City Inspector:

    eandrewsText BoxJ-01

  • ADH100 AdhesiveGeneralADH100 is a single component opaque adhesive formulatedto bond PVC risers to Orenco grade rings and PRTA seriestank adapters. Upon curing, the seal created is both waterand chemical resistant.

    Standard ModelADH100

    Submittal Data Sheet

    SpecificationsGel time is approximately 10 minutes; ultimate bond strength occurs after 24 - 72 hours at 70˚ - 85˚ F. Cure time is increasedgreatly with a decrease in temperature; not recommended for use in temperatures below 32˚ F.

    Expected shelf life is approximately 5 years when stored at temperatures between 45˚ - 85˚ F.

    NSU-RLA-ADH-3Rev. 2.2, © 1/01

    ApplicationsADH100 is used to bond PVC risers to Orenco grade ringsand PRTA series tank adapters.

    eandrewsText BoxJ-02

  • © 2009 Orenco Systems® Inc. NTD-SBEX-1Rev. 1.0, © 5/09

    Page 1 of 2

    External Splice BoxTechnical Data Sheet

    Applications The Orenco® External Splice Box attaches outside the access riser of an underground tank. It is engineered specifically for water and wastewater treatment systems and is especially suited for use in locations prone to high groundwater and other wet conditions. Its separate conduit hubs, large volume, and optional dividers make it useful for maintaining isolation of high and low voltage wires where needed. It has four cord grips which accom-modate power cords for floats and pumps of 0.170 - 0.470 inches (4.3 - 11.9 mm) in diameter. Unused cord grips can be plugged watertight with the supplied cord grip plugs. Each External Splice Box is provided with a hole-cutting template to simplify installa-tion on the riser.

    General To specify the Orenco External Splice Box for your installation, require the following:

    need to open the riser lid

    3 3) for easy wiring access and to accommodate multiple wiring configurations

    below minimum burial depth

    exposure, suitable for external applications

    tage wires from separate conduits or direct-bury cable

    SBEX1-4 -

    External splice box

    Blank = no divider platesP = divider plates

    Standard Models

    Nomenclature

    The External Splice Box is molded of a UL (f1) rated PVC alloy. It has a UL Type 6P list-ing for prolonged submergence.

    eandrewsText BoxJ-03

  • © 2009 Orenco Systems® Inc.NTD-SBEX-1Rev. 1.0, © 5/09Page 2 of 2

    External Splice Box (continued)

    Materials of Construction

    O-rings Buna rubber

    Physical Specifications 3 3)

    accommodated

    accommodated 1 in. (with coupling) ½ in. (with fitting or bell end)

    into riser (hole-cutting template included)

    (114 mm)

    Optional divider

    plate

    Optional divider

    Threaded cap

    (4)

    plugs (3)

    hub plug (1)

    eandrewsText BoxJ-04

  • Applications Orenco Biotube® Pump Vaults are used to filter effluent that is pumped from septic tanks or separate dosing tanks in STEP systems and onsite wastewater treatment systems. They re- move two-thirds of suspended solids, on average. Pump vaults house a Biotube effluent filter and one or two Orenco high-head effluent pumps and can be used in single-compartment septic tanks with flows up to 40 gpm. When flows are greater than 40 gpm, a double-compartment septic tank or separate dosing tank is recommended.

    General The Orenco Biotube Pump Vault includes a molded poly- ethylene housing with an internal filter cartridge constructed of polypropylene and PVC. Schedule 80 PVC support pipes are included to suspend the vault in a tank opening. The filter car-tridge can be removed without pulling the pump or the vault. Effluent enters through inlet holes around the perimeter of the Biotube vault and flows through the Biotubes to the external flow inducer. The external flow inducer accommodates one or two pumps. Orenco Biotube Pump Vaults are covered by U.S. patents #4,439,323 and 5,492,635.

    Standard ModelsPVU57-1819-L.

    Nomenclature

    © 2009 Orenco Systems® Inc. NTD-PVU-LACEYRev. 1.0, © 6/09

    Page 1 of 2

    Universal Biotube® Pump VaultsTechnical Data Sheet

    For use with Orenco 4-in. Submersible Effluent Pumps

    Materials of ConstructionSupport pipe: Schedule 80 PVCBiotube® vault: PolyethyleneBiotube cartridge: Polypropylene/PVCFloat stem: Schedule 40 PVCDrain valve ball: Polypropylene

    External flow inducer

    Inlet holes

    Side view

    Support pipe

    Support pipe length:L = Long support pipes for 30" riser

    Inlet hole height (inches)

    Cartridge height (inches)

    57 - 18 19PVU

    Vault height

    Universal Pump Vault

    - L

    eandrewsText BoxJ-05

  • DRAW

    N BY

    : CD

    Ore

    nco

    Syst

    ems

    Inco

    rpor

    ated

    RDa

    te:

    6/1/

    06

    CUST

    OM D

    RAW

    ING:

    REVI

    SION

    :1

    Instructions

    Installation Instruction

    X-STYLE VAULT INSTRUCTIONSPART# INSTR-X

    1" SCH. 40 PVCCUT LENGTH 48 3/4"

    18

    DO NOT GLUE JOINT

    USE REINFORCED TOP

    PVUP

    57-1

    819-

    L

    WOR

    K OR

    DER

    #

    APPR

    OVED

    BY:

    MAS

    TER:

    1391

    37

    3055

    73

    Universal Biotube® Pump Vaults (continued)Technical Data Sheet

    © 2009 Orenco Systems® Inc. NTD-PVU-LACEYRev. 1.0, © 6/09

    Page 2 of 2

    SpecificationsModel PVU57-1819-LVault height (F) 57 in. Lowest float setting point (G) 29 in. Inlet hole height (H)* 19 in. Biotube® cartridge height (J) 18 in. Biotube mesh opening 0.125 in.Filter flow area 4.4 ft2 Filter surface area 14.5 ft2 Maximum flow rate 140 gpm

    * May vary depending on the configuration of the tank.

    Side view cutaway

    C

    D

    Top view

    Support pipes

    H

    F

    2" min.

    J

    G

    A

    B

    DimensionsA 3.0 in.B 4.0 in.C 17.3 in.D 16.6 in.E 12.0 in.

    Drain valve ball

    E

    eandrewsText BoxJ-06

  • Technical Data Sheet

    Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-MF-MF-1Rev. 3.0, © 03/17

    Page 1 of 2

    Float Switch Assemblies

    Materials of ConstructionFloat housing Impact-resistant, noncorrosive PVC plastic for use in liquids up to 140˚ F (60˚ C)

    Float cord, Flexible 2-conductor (UL, CSA) SJOOW; Super Vu-Tron® P and N models Supreme, yellow

    Float cord, Flexible 2-conductor (UL, CSA) SJOW; water-resistant All other models (CPE); neoprene coating

    Float collar ABS

    ApplicationsFloat switches are used to signal liquid level positions for alarm and pump control applications. Orenco float switch assemblies can be mounted in pump vaults, effluent screens, pump basins, and risers.

    GeneralAll models listed are UL listed and CSA certified for use in water or sew-age. Non-mercury float switches (models B, C, N, and P) are used where components containing mercury are prohibited.

    Float switches are typically ordered in assemblies that include one or more switches mounted on a 1-inch PVC float stem. ABS float collars are used to provide secure mounting that is easily adjustable.

    Normally-open “P” float switches have a blue cap for easy identifica-tion; normally-closed “N” float switches have a red cap. “P” and “N” model float switches use Super Vu-Tron® electrical cords for superior chemical and water resistance.

    Standard ModelsB, C, G, N, P

    Product Code Diagram

    When ordering float switch assemblies, remember to list float switches from the top of the float stem down. An “MFPBN-” nomenclature indi-cates one “P” switch at the top of the stem, one “B” in the middle of the stem, and one “N” switch at the bottom of the stem; an “MF2PN-” indicates “P” switches at the top and middle of the stem, and one “N” switch at the bottom of the stem.

    The “On” and “Off” positions describe normally open floats. For normally closed floats, the functions are reversed.

    On

    Off

    Float collar

    Float tether

    Set point

    Draw

    dow

    n

    X

    Y

    Float stem

    MF

    Cord length option:Blank = 10 ft (3 m), standard20 = 20 ft (6 m)30 = 30 ft (9 m)50 = 50 ft (15 m)

    Number of float switches (when using multiples of the same float switch model):Blank = no multiples of the same float switch model

    Float stem length:Blank = no float stem (floats and collars only)19, 21, 27, 33, 37, 39, 45, 51, 57, 66 = stem length, in.5, 11 = stem length, in. (for elbow-style float brackets)

    Application:FS = field setFTL = elbow-style (base-inlet filters only)PB = pump basinV = pump vault (standard float settings)STEP = Standard float settings for STEP STEPRO = Standard float settings for STEP with redundant off SVCOM = Standard float settings for VCOM simplex

    - -

    Float switch assembly

    Float switch models (listed in order from the top of the float stem down):B, C, G, N, P

    MFPG-27V-LACEY

    P

    G

    eandrewsText BoxJ-07

  • © 2009 Orenco Systems® Inc.NTD-MF-MF-LACEYRev. 1.2, © 7/09Page 2 of 2

    Float Switch Assemblies (continued)

    Float State1 Type2 IR3 Volts Amps hp Tether X Y Drawdown4

    Signal-rated mercury floats5 (for control switch applications)

    A Modela Normally open Mercury Yes n/a n/a n/a 2.00 in. n/a n/a n/a

    Motor-rated floats (for pump switch applications)

    G Model Normally open Mercury No 120 V 15A ¾ hp 2.00 in. 1.50 in. 3.00 in. 4.50 in.

    240 V 15A 2 hp 3.00 in. 1.75 in. 3.00 in. 4.75 in.

    4.00 in. 2.00 in. 3.50 in. 5.50 in.

    a. Suitable for use with VCOM and MVP.

    Signal- and Motor-Rated Float Switch Matrix

    Notes1 State: normally open or normally closedThe default state of a float — normally open or normally closed — refers to the contact positions in the float when the float is resting (down). Float switches have an internal contact. The terms “normally open” (N/O) and “normally closed” (N/C) refer to the state of the float switch contact in the down position. A normally open float switch has an open contact (off) in the down position and a normally closed float switch has a closed contact (on) in the down position. Different panel functions require different types of float switches. Most applications require float switches that are normally open. One notable exception is the redundant off and low-level alarm function that requires a nor-mally closed float switch, except with MVP and VCOM panels.2 TypeFloats have mechanical or mercury contactor types. The important distinction between these is that mercury floats are not rated for potable water.

    3 IR (intrinsically safe relay)Approved for use with intrinsically safe, Class I, Division 1 applica-tions, where reliable float switch operation with very low current is required. 4 DrawdownDrawdown (in inches) refers to the difference in liquid level between a float switch’s activation and deactivation points. Drawdown can be altered by adjusting the tether length of the float switch cord. When selecting float switches, keep in mind that any float switch that can directly start and stop a pump (one that has no motor contactor in the control panel) should have a drawdown capability, to avoid rapid cycling of the pump.

    eandrewsText BoxJ-08

  • © 2009 Orenco Systems® Inc. NTD-HV-HV-LACEYRev. 1.1, © 6/09

    Page 1 of 1

    Discharge AssembliesTechnical Data Sheet

    ApplicationsOrenco Discharge Assemblies are used to convey effluent from a pump to the exterior of a riser or pump basin. They come in high-head configuration, for use with submersible turbine pumps. An external flex extension is recommended for installations where tank settling may occur to avoid line breakage during settling. Discharge assemblies for use in 1500-gallon STEP tanks include a ¼" flow control orifice.

    GeneralOrenco Discharge Assemblies are corrosion-resistant and adjustable for a proper fit. Discharge assemblies are com-posed of PVC valves and flexible hose that simplify installation and maintenance. The flexible hose damps vibrations from the pump and allows for easy installation. All parts are either sol-vent welded or threaded and sealed with Teflon® paste. Teflon® is a registered trademark of DuPont.

    Standard ModelsHV100BPR80, HV100BFCPR-80, HVX100PR-80, PPSC-10

    Nomenclatures

    Stainless steel check valve

    Discharge diameter:10 = 1 in.

    Pump part

    PP - 10SC

    Options:PR = High pressure

    Discharge diameter:100 = 1 in.

    Flex extension

    Pump discharge assembly

    Schedule 80

    HV - 80X PR100

    Materials of ConstructionComponent MaterialBall valve Schedule 40 PVCFlowmatic check valve Stainless steelPipe and fittings Schedule 80 PVCFlexible hose PVCExternal flex hose PVCFlow control disc Schedule 80 PVCGate valve Schedule 80 PVCUnions Schedule 80 PVCHigh-pressure flex hose Special elastomer compound

    Component Working Pressure RatingsValves 150 psi (10 bar) at 73˚ F (23˚ C)Unions 150 psi (10 bar) at 73˚ F (23˚ C)

    High-Pressure Hose SpecificationsThickness and working pressures at 73˚ F (23˚C) Size Wall Working (Nominal) thickness pressure 1.00 in. 0.235 in. 250 psi

    kbi

    High-Pressure HoseHose and Valve Assembly

    Stainless Steel Check Valve

    Options:B = Ball valveFC = ¼" flow controller (1500-gallon STEP tanks only)PR = High pressure

    Discharge diameter:100 = 1"

    Pump discharge assembly

    Schedule 80

    HV - 80100 ¼" flow control (for 1500-gallon STEP tanks only)

    HV100BFCPR-80 HVX100PR PPSC-10

    BFCPR

    eandrewsText BoxJ-09

  • Features/SpecificationsOrenco 4" Submersible Effluent Pump has the following features:

    Minimum 24-hour run-dry capability with no deterioration in pump life or performance1/8" bypass orifice (patent pending) to ensure flow recircula-tion for motor cooling and to prevent air bind

    ownership

    Standard Model

    Nomenclature

    ApplicationsOrenco® 4" Submersible Effluent Pumps are designed to trans-

    plastics; all are field-serviceable and repairable with common -

    ® are used in a variety

    -

    to be used with a Biotube®

    connection

    Bypass orifice

    Suction connection

    su

    per s

    tain

    less

    mot

    or

    LR80980LR2053896

    PF Series 4" Submersible Effluent Pump

    Technical Data Sheet

    © 2011 Orenco Systems® Inc. NTD-PU-PF-LACEYRev. 1.4, © 12/11

    Page 1 of 2

    Voltage (nameplate):1 = 115 VAC2 = 230 VAC

    Frequency:1 = Single-phase 60 Hz

    Horsepower:05 = ½ hp

    Nominal flow (gpm):10 = 10 gpm (for 1500-3000 gallon STEP tanks)20 = 20 gpm (for 8000-gallon STEP tanks)

    PF series 4" submersible effluent pump

    PF 05 1

    10

    1

    eandrewsText BoxJ-10

  • Specifications

    60 Hz

    Model

    1 ⁄8 ®2 Biotube®

    PF Series High-Head Effluent Pumps

    Desi

    gn g

    pm

    (in.)

    Hors

    epow

    er

    Phas

    e

    Nam

    epla

    te

    volta

    ge

    Actu

    al

    volta

    ge

    Desi

    gn fl

    ow

    amps

    Max

    am

    ps

    Impe

    llers

    Disc

    harg

    e si

    ze1

    Leng

    th (i

    n.)

    Min

    . liq

    uid

    le

    vel,2

    (in.)

    Wei

    ght,3

    (lb)

    Rate

    d cy

    cles

    /day

    Materials of Construction

    ®

    Suction connection: Stainless steel

    © 2011 Orenco Systems® Inc.NTD-PU-PF-LACEYRev. 1.4, © 12/11Page 2 of 2

    Using a Pump Curvepump curve helps you determine the best pump for your

    a graphical representation of a pump’s optimal performance nominal flow rate — the

    -

    Orenco’s PumpSelect

    Tota

    l dyn

    amic

    hea

    d (T

    DH) i

    n fe

    et

    Flow in gallons per minute (gpm)142 4 6 8 10 16 18 20 22 24 26 28 30120

    20

    0

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    PF Series 60-Hz 0.5 hp PF100511

    PF200512

    PF1005with 1/4"

    flow control

    eandrewsText BoxJ-11

  • © 2009 Orenco Systems® Inc. NTD-CP-S-LACEYRev. 1.0, © 6/09

    Page 1 of 1

    Simplex Control Panels – Lacey, WATechnical Data Sheet

    ApplicationsOrenco Simplex Control Panels are used to control effluent pumps, alarms, and other equipment as specified in pressure sewers and onsite septic systems.

    GeneralOrenco Simplex Control Panels are specifically engineered for pressure sewer (STEP) systems, onsite septic treatment systems, and pump control into conventional gravity systems. Standard features include circuit breakers, an automatic/manual/off toggle switch, automatic motor control operation, and an audible/visible high water level alarm with auto reset.

    Standard ModelsS1DS-LACEY

    Nomenclature

    Materials of ConstructionEnclosure UV-resistant fiberglass, UL Type 4XHinges Stainless steel

    DimensionsHeight (in.) 11.5Width (in.) 9.5Depth (in.) 5.4

    SpecificationsPanel ratings 120 V, 3/4 hp, 14 A, single phase, 60 Hz 1. Motor-start 16 FLA, 1 hp, 60 Hz; 2.5 million cycles at contactor FLA (10 million at 50% of FLA) 2. Circuit 120 V, 10 A, OFF/ON switch, Single pole breakers 3. Toggle switch Single-pole, double-throw HOA switch, 20 A 4. Audio alarm 95 dB at 24 in., warble-tone sound, UL Type 4X 5. Audio alarm 120 V, automatic reset, DIN rail mount silence relay6. Visual alarm 7/8-in. diameter red lens, “Push-to-silence,” 120 V LED, UL Type 4X7. Disconnect switch Single-pole, single 1-1 throw, 20 A (not shown)

    AUTO

    OFF

    MAN

    Option:DS = Disconnect switch

    Simplex panel, 120 VAC

    S1 DS - LACEY

    eandrewsText BoxJ-12

  • Simplex Operation

    HHHiiiggghhh LLLeeevvveeelll AAAlllaaarrrmmm::: This float activates the alarm light and audible alarm when lifted. The audible alarm may be silenced by pressing the PUSH TO SILENCE button. The alarm light will remain on until the float is lowered.

    PPPuuummmppp OOOnnn///OOOffffff::: This float turns on the pump when lifted. The pump will continue to run until the float is lowered.

    AALASCBDSMPBSR

    Key= Factory Wire= Field Wire= Audio Alarm= Alarm Light= Audio Silence Switch= Controls Circuit Breaker= Disconnect Switch= Motor Contactor= Pump Circuit Breaker= Silence Control Relay

    Motor PowerVoltageMax AmpsHorsepowerHertzPhaseShort Circuit Current Rating:5,000A rms symetrical, 240V max

    ControlsVoltageMax AmpsHertzPhase

    Panel ModelS1 DS Lacey

    Enclosure RatingUL Type 4X

    Orenco Systems, Inc.

    43

    High LevelAlarm

    (Y-Yellow)

    Pump On/Off(G-Green)

    Incoming Power Wiring Pump & Float Wiring

    PowerL1

    NeutralN

    431 2 3 4 5 6 7 8

    Panel Wiring DiagramModel S1 DS Lacey

    Ground

    3

    Neutral N

    M

    T2L2

    T1L1

    42

    Note: Motor must have

    internal overload protection

    Pump115 VAC / 1 Hp.1 Phase / 60 Hz.

    From Main Power Panel115 VAC, 1 Phase, 60 Hz.

    GroundLug

    EDW-WD-S-131Rev 7.1 © 6/4/09

    Power L1

    CB 10A

    PB 20A

    M

    A2A1OFF

    HAND

    AUTO

    FS2 Pump On

    A2A1SR

    SR1411

    65 FS3 High Level

    -+A

    SR1211

    AS

    87

    X2X1

    RAL

    Pump115 VAC / 1 Hp.1 Phase / 60 Hz.

    Blu

    e

    Bro

    wn

    Ye

    llow

    Ora

    nge

    Red

    White

    DS

    1

    120VAC161601

    120VAC5601

    PUMPGreen

    Simplex Operation

    HHHiiiggghhh LLLeeevvveeelll AAAlllaaarrrmmm::: This float activates the alarm light and audible alarm when lifted. The audible alarm may be silenced by pressing the PUSH TO SILENCE button. The alarm light will remain on until the float is lowered.

    PPPuuummmppp OOOnnn///OOOffffff::: This float turns on the pump when lifted. The pump will continue to run until the float is lowered.

    AALASCBDSMPBSR

    Key= Factory Wire= Field Wire= Audio Alarm= Alarm Light= Audio Silence Switch= Controls Circuit Breaker= Disconnect Switch= Motor Contactor= Pump Circuit Breaker= Silence Control Relay

    Motor PowerVoltageMax AmpsHorsepowerHertzPhaseShort Circuit Current Rating:5,000A rms symetrical, 240V max

    ControlsVoltageMax AmpsHertzPhase

    Panel ModelS1 DS Lacey

    Enclosure RatingUL Type 4X

    Orenco Systems, Inc.

    43

    High LevelAlarm

    (Y-Yellow)

    Pump On/Off(G-Green)

    Incoming Power Wiring Pump & Float Wiring

    PowerL1

    NeutralN

    431 2 3 4 5 6 7 8

    Panel Wiring DiagramModel S1 DS Lacey

    Ground

    3

    Neutral N

    M

    T2L2

    T1L1

    42

    Note: Motor must have

    internal overload protection

    Pump115 VAC / 1 Hp.1 Phase / 60 Hz.

    From Main Power Panel115 VAC, 1 Phase, 60 Hz.

    GroundLug

    EDW-WD-S-131Rev 7.1 © 6/4/09

    Power L1

    CB 10A

    PB 20A

    M

    A2A1OFF

    HAND

    AUTO

    FS2 Pump On

    A2A1SR

    SR1411

    65 FS3 High Level

    -+A

    SR1211

    AS

    87

    X2X1

    RAL

    Pump115 VAC / 1 Hp.1 Phase / 60 Hz.

    Blu

    e

    Bro

    wn

    Ye

    llow

    Ora

    nge

    Red

    White

    DS

    1

    120VAC161601

    120VAC5601

    PUMPGreen

    eandrewsText BoxJ-13

  • GPump On

    YHigh Level Alarm Pump Cord

    Splice Box Wiring Diagram

    Cord GripHand tighten each cord grip

    so that the cord will not easilyslide through the grommet.

    YG

    Yellow

    Green

    KeyBlack Wire

    Green WireWhite Wire

    Heat Shrink &Butt Connector *

    Attention: Failure to follow splicinginstructions will void warranty

    Note: Multi-function floats willhave more than one marker

    --

    Float Tag Colors

    EDW-SB-S-8Rev 2.2 ©12/06/11

    Drawing No.

    EDW-SB-S-8Float Function Color Code

    YGSplice Box Model

    SBEX1-4Control Panel Series

    Lacey Simplex

    * Refer to drawing EIN-SB-SB-1 for splicing instructions.

    To Terminal#6

    Orange

    To Terminal#5

    Yellow

    To Terminal#3

    RedTo Terminal

    #4White

    To Terminal#8

    Brown

    To Terminal#7

    Blue

    To GroundLug

    Green

    eandrewsText BoxJ-14

  • © 2009 Orenco Systems® Inc. NTD-RLA-RR-LACEYRev. 1.0, © 6/09

    Page1 of 1

    Access Risers Technical Data Sheet

    GeneralOrenco Access Risers are constructed of ribbed PVC pipe and are available in 24-in. and 30-in. diameters. The 24-in. ribbed ris-ers are available in three-inch increments up to 14 ft in length. The 30-in. risers are available in one-inch increments up to 13 ft in length.

    Standard ModelsRR24XX, RR30XX

    Nomenclature

    ApplicationsOrenco’s Access Risers provide access to septic tank openings and can be cast into the tops of concrete tanks, bonded in place, or bolted down using a riser tank adaptor. They can also be used as valve enclosures.

    Materials of ConstructionRibbed Risers: PVCBolt catch (30" risers only) PVC

    SpecificationsModel RR24XX RR30XXI.D. (in.) 23.50 29.50Wall Thickness - excluding ribs (in.) 0.20 0.20O.D. - including ribs (in.) 25.63 31.00Weight per foot (lb) 19 18

    Riser diameter:24 = 24 in. 30 = 30 in.

    Riser height, inches

    Ribbed riser

    RR

    eandrewsText BoxJ-15

  • © 2008 Orenco Systems® Inc. NTD-RLA-RLA-LACEYRev. 1.0, © 6/09

    Page 1 of 1

    RLA Riser-to-Lid AdaptersTechnical Data Sheet

    ApplicationsOrenco® riser-to-lid adapters (RLAs) provide a secure, water-tight method of attaching an Orenco fiberglass lid to a 24-in. or 30-in. ribbed PVC access riser.

    RLAs are especially useful when the top of the riser is uneven or has a damaged edge.

    GeneralRLA adapters can be attached to 24-in. or 30-in. risers to sim-plify bolting a lid to the riser.

    Standard ModelsRLA24, RLA30

    Nomenclature

    Materials of ConstructionAdapter ABSO-ring EPDM SpecificationsDimensions in inches (mm) RLA24 RLA30

    A – Adapter height 1� (32) 1� (32)

    B – Socket or lip width 1 (25) 1 (25)

    C – Inside diameter 227⁄8 (581) 28⇥ (724)

    D – Outside diameter 25⇥ (648) 31 (787)

    E – Socket depth 3⁄8 (10) N/A

    Riser style Perma-Loc™ Perma-Loc Ultra-Rib™

    Lid bolt

    RLA24 adapter

    24-in. riser

    Fiberglass lid

    RLA24 riser-to-lid adapter

    DC

    A

    BE

    RLA30 riser-to-lid adapter

    30-in. riser

    Lid bolt

    RLA30 adapter

    Fiberglass lid

    DC

    A

    B

    RLA

    Riser-to-lid adapter

    Adapter diameter (inches):24 = 24"30 = 30"

    eandrewsText BoxJ-16

  • © 2009 Orenco Systems® Inc. NTD-RLA-PRTA-LACEYRev. 1.1, © 6/09

    Page 1 of 1

    PRTA Tank AdaptersTechnical Data Sheet

    ApplicationsPRTA tank adapters are used to provide a structural, water-tight method of installing an 8", 24", or 30" access riser over a tank opening.

    GeneralOrenco’s PRTA tank adapters are molded plastic products and therefore have excellent part-quality and consistency. PRTA tank adapters are designed to be cast into a tank top, provid-ing a way to affix inspection or access risers.

    Orenco's 8" adapters provide a slip-fit for 8" IPS PVC inspec-tion risers. Risers are placed in the inner sleeve and fixed into place with PVC cement. On 24" and 30" adapters, the O.D. of the vertical flange matches the I.D. of Orenco’s ribbed risers, which provides a suitable joint to seal with ADH100 adhesive.

    Standard ModelsPRTA08, PRTA24, PRTA30

    Nomenclature

    SpecificationsDimensions (in.) PRTA08 PRTA24 PRTA30A 9 ½ — —B 8 5⁄8 — —C 5⁄32 — —D (lip width) 1/8 — —E ½ — —F 4 5⁄8 — —G — 23 ½ 29 ½H — 27 35I — ¾ ¾J — 1 ¾ 2 ½K — 3 ¼ 3

    Materials of ConstructionTank adapter (8") Sand-coated PVCTank adapter (24" and 30") ABS

    ABS tank riser adapter

    PRTA

    Riser diameter:08 = 8" (8" IPS)24 = 24" (Perma-Loc, Ultra-Rib, KOR FLO)30 = 30" (Perma-Loc, Ultra-Rib)

    G

    H

    K

    J

    I

    24" and 30" tank adapters

    8" tank adapter

    AB

    C

    DF

    ECasting groove

    Seating lip

    eandrewsText BoxJ-17

  • Pipe GrommetsGeneralOrenco Pipe Grommets are constructed of corrosion-resistant rub-ber to provide long-lasting seals. Grommets conform to standardIPS sizes. Not all models conform exactly to the depiction shown.

    Standard ModelsG05L, G075L, G1L, G125L, G150L, G2L, G3L, G4L, G6L

    Nomenclature

    Submittal Data Sheet

    ODID

    GW

    GD

    T

    SpecificationsDimensionsModel G05L G075L G1L G125L G150L G2L G3L G4L G6LOD (inches) 1 1/4 1 1/2 1 7/8 2 1/8 2 1/2 3 7/8 5 6 8 1/8ID (inches) 3/4 1 1 1/4 1 1/2 1 3/4 2 1/8 3 1/4 4 3/16 6 11/16GD (inches) 1 1 1/4 1 5/8 1 3/4 2 1/8 2 11/16 3 13/16 4 15/16 7 5/8GW (inches) 3/16 3/16 1/4 1/4 1/4 5/16 5/16 1/4 1/4T (inches) 1/2 7/16 9/16 5/8 5/8 15/16 15/16 7/8 13/16Holesaw Size (inches) 1 1 1/4 1 9/16 1 3/4 2 1/8 2 3/4 3 7/8 5 7

    Material of Construction:

    EPDM synthetic rubber in accordance with MIL-STD-417, 60 durometer.

    NSU-RLA-PG-1Rev. 3.4, © 7/03

    ApplicationsOrenco Pipe Grommets are used to provide a seal to prevent thepassage of liquids through pipe ports.

    G

    Indicates grommet diameter:05 = 1/2"075 = 3/4"1 = 1"125 = 1-1/4"150 = 1-1/2"2 = 2"3 = 3"4 = 4"6 = 6"

    Grommet

    LIndicates not installed

    eandrewsText BoxJ-18

  • Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-RLA-FL-2Rev. 2.0, © 03/17

    Page 1 of 1

    Fiberglass CapsTechnical Data Sheet

    GeneralOrenco Fiberglass Caps are molded using fiberglass reinforced polyes-ter resin. Both non-skid (standard) and smooth surfaces are available. Standard color for the non-skid surface is green. Standard color for the smooth surface is white. Fiberglass caps are available with or without bolt holes and gaskets.

    Standard ModelsFL8G, FL8GT, FL8GS

    FL12G, FL12GT, FL12GS, FL12GTU

    FL15G, FL15GT, FL15GS

    Product Code Diagram

    Materials of ConstructionLid Fiberglass

    Gasket Polyurethane

    ApplicationsOrenco’s Fiberglass Caps are used as access covers for valve boxes and tank hatches. These lids are rated for pedestrian traffic only.

    • FL8 caps fit 8-inch dia. IPS pipe, 8.63-inch (219 mm) O.D.

    • FL12 caps fit 12-inch dia. PIP pipe, 12.24-inch (311 mm) O.D.

    • FL12GTU caps fit 12-inch dia. Ultra-Rib™ pipe, 13.1-inch (333 mm) O.D.

    • FL15 caps fit 15-inch dia. PIP pipe, 15.3-inch (389 mm) O.D.

    SpecificationsDimensions FL8XX FL12XX FL12GTU FL15XX

    O.D. in. (mm) 8 7/8 (225) 12 1/2 (318) 13 3/4 (349) 15 5/8 (397)

    I.D. in. (mm) 8 5/8 (219) 12 1/4 (311) 13 3/8 (339) 15 3/8 (391)

    Top thickness in. (mm) 3/16 (4.8) 3/16 (4.8) 3/16 (4.8) 3/16 (4.8)

    Lip thickness in. (mm) 1/8 (3.2) 1/8 (3.2) 1/8 (3.2) 3/16 (4.8)

    Bolt holes for top attachment shown

    FL

    Attachment method options:Blank = slip fitS = side screwT = top boltTU = top bolt, for 12-in. (300-mm) Ultra-Rib™ risers

    Color and non-skid options:Blank = green color, non-slip surfaceW = white color, smooth surface

    Gasket options:Blank = no gasket, standardG = gasket

    Lid diameter, in. (mm):8 = 8 (200)12 = 12 (300)15 = 15 (375)

    Fiberglass lid

    FL8G

    eandrewsText BoxJ-19

  • Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-RLA-FL-4Rev. 2.0, © 03/17

    Page 1 of 1

    DuraFiber™ Access LidsTechnical Data Sheet

    ApplicationsOrenco® DuraFiber™ Access Lids provide a secure, damage-resistant cov-ering for ribbed PVC and HDPE risers, pump basins, and access ports. They are not recommended for vehicular traffic. 30-inch (750-mm) DuraFiber lids are not compatible with 30-inch (750-mm) RLA Riser-Lid-Adapters or 30-inch (750-mm) Perma-Loc™ pipe. For these products, use Orenco’s FLF-Series lids.

    GeneralDuraFiber Access Lids are constructed of resin-infused fiberglass fabrics for extreme durability and damage resistance, with breaking strengths in excess of 20,000 pounds (9,000 kg).

    They feature flat-style flanges for easier access, allowing clean, flush-to-grade installations. They have cored centering rings for aligning lids with risers. And they also have urethane gaskets to help provide watertight seals.

    DuraFiber Lids feature a non-skid surface for better grip and aesthetics, a molded-in caution statement, and room for a customer logo. They come with four 5⁄16-inch stainless steel flathead socket cap screws and a hex key wrench.

    Durafiber Lids are available with optional insulation, installed at the factory or in kits that can be installed in the field.

    Standard ModelsFLD24G, FLD24GATX, FLD24GW, FLD30G, FLD30GATX, FLD30GW

    Product Code Diagram FLD

    Insulation:*Blank = no insulationI2 = 2-inch (50-mm) insulation installedI4 = 4-inch (100-mm) insulation installed

    Vent and filter options:Blank = no vent or filter optionsV = ventCF = carbon filter

    Gasket options:G = gasket (standard) Blank = no gasket

    Lid diameter, in. (mm):24 = 24 (600)30 = 30 (750)

    DuraFiber™ fiberglass lid

    * Insulation has an R-value of 10 per 2-inch (50-mm) increment.

    Color and logo options:Blank = green color lidB = brown color lidC = custom logoATX = AdvanTex® logoW = warning label

    Materials of Construction:Lid Fiberglass reinforced polyester

    Gasket Urethane

    Centering ring core Structural foam

    Mounting hardware Stainless steel

    Insulation (optional) Closed-cell foam

    Insulation mounting hardware Stainless steel

    Specifications Model FLD24XX FLD30XX

    A in. (mm) 26 (660) 33 (838)

    B, in. (mm) 1½ (38) 1½ (38)

    C, in. (mm) 23¼ (590) 29¼ (743)

    Gasket width, in. (mm) ¾ (19) ¾ (19)

    Bolt hole diameter, in. (mm) 5⁄16 (8) 5⁄16 (8)

    Weight, lbs (kg) 11 (5) 20 (9)

    Bolt holes, per lid 4 4

    B

    A

    C

    FLD24G

    eandrewsText BoxJ-20

  • Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-RLA-FL-5Rev. 2.0, © 03/17

    Page 1 of 1

    FLF-Series Fiberglass Access LidsTechnical Data Sheet

    ApplicationsOrenco® FLF-Series Fiberglass Access Lids provide a secure cover-ing for risers, pump basins, and access ports. They are capable of supporting a 2500-lb (1134-kg) wheel load; however, they are not designed or recommended for vehicular traffic. FLF-series lids will fit directly onto the riser types listed in the Specifications section.

    FLF30 lids are required for retrofits on 30-in. (750-mm) Perma-Loc™ access risers or 30-inch (750-mm) Orenco RLA riser-to-lid adapters.

    GeneralOrenco FLF-Series Fiberglass Access Lids are molded using fiberglass reinforced polyester resin with a structural foam core for added dura-bility and longevity. The finish is green or brown and the top surface is textured to provide a nonskid surface. Gasketed lids include a polyurethane gasket. FLF Lids come with four 5⁄16-inch stainless steel flathead socket cap screws and a hex key wrench.

    Standard ModelsFLF18G, FLF21G, FLF30G

    Product Code Diagram

    Materials of ConstructionLid Fiberglass

    Core Structural foam

    Gasket Polyurethane

    SpecificationsModel FLF18G FLF21G FLF30G

    Lid O.D. in. (mm) 20.25 (514) 22.5 (572) 32.6 (829)

    Groove I.D. in. (mm) 17.50 (445) 20.25 (514) 28.75 (730)

    Avg. thickness in. (mm) 0.75 (19) 0.75 (19) 1.0 (25)

    Weight lb (kg) 4.15 (1.8) 6.25 (2.8) 11.50 (5.2)

    Applications Ultra-Rib™ Ultra-Rib Perma-Loc™ Perma-Loc Kor Flo™

    BottomTop

    Cutaway view

    Core Groove I.D. Gasket Lid O.D.

    FLF

    Color and logo options:Blank = green color lidB = brown color lidC = custom logoATX = AdvanTex® logo

    Lid options:G = gasketV = ventCF = carbon filter installed in lidI2 = 2-in. (50-mm) insulation*I4 = 4-in. (100-mm) insulation

    -

    Lid diameter, in. (mm):18 = 18 (450)21 = 21 (525)30 = 30 (750)

    Fiberglass lid, FLF-series

    * Lid insulation has an R-value of 10 per 2-inch (50-mm) incrementNote: For fiberglass basin bottoms without holes, order FLF18 or FLF21

    FLF30G

    eandrewsText BoxJ-21

  • © 2009 Orenco Systems® Inc. NTD-SC-LACEYRev. 1.0, © 6/09

    Page 1 of 1

    Service ConnectionsTechnical Data Sheet

    Applications Orenco® Service Connections are used to isolate pressure mainlines from individual service laterals, by combining a ball valve and check valve into one component. Service connections also help simplify inspection and maintenance procedures.

    General Orenco’s Service Connections are constructed of Schedule 80 PVC. All models built for the City of Lacey, WA include a 1-in. diameter inlet elbow and a 1 1/4-in. diameter outlet elbow.

    Standard ModelsSC125-LACEY

    Nomenclature

    Materials of ConstructionPipe Schedule 80 PVCFittings Schedule 80 PVCCheck valve (KBI) Schedule 80 PVCBall valve (KBI) Schedule 80 PVC

    SpecificationsA - Width (in.) 3.75B - Overall length (in.) 18.63C - Height (in.) 5.75Inlet diameter (IPS nom.) 1 in.Outlet diameter (IPS nom.) 1.25 in.

    Discharge diameter:125 = 1¼ in.

    Service connection

    125SC - LACEYA

    B

    C

    eandrewsText BoxJ-22

  • NCF-CO-LACEY8000WM Rev. 1.0, 08/17

    CERTIFICATE OF ORIGIN CITY OF LACEY

    Engineered wastewater collection system SMALL COMMUNITY SYSTEM

    (Using 8000 Gallon Tank & Wall Mounted (WM) Control Panel) The following Collection System On-Lot Package is certified to have been manufactured by Orenco Systems®, Inc., Sutherlin, Oregon. The On-Lot Package equipment listed below is covered by an extended factory warranty under the terms and conditions of Orenco Systems’ Certificated Products Limited Warranty in effect at the time of sale.

    On-Lot Package Code: PSA20-LACEY8000WM

    Adhesive: ........................................................................... (4) ADH100

    Biotube® Pump Vault: ........................................................ (1) PVU84-3625-L

    Float Assembly: .................................................................. (1) MFPGN-39V-50-LACEY

    Discharge Assembly: ......................................................... (2) HV100BPRX-80-LACEY

    Check Valve: ...................................................................... (2) PPSC-10

    Effluent Pump: .................................................................... (2) PF200512-50

    Control Panel: .................................................................... (1) DAX2IRRODSFL-LACEY-WM

    Homeowner’s Manual: ....................................................... (1) PMHOMEMANUAL

    Installation Manual: ............................................................ (1) PMPSPPINST

    Certificate of Origin: .......................................................... (1) NCF-CO-LACEY8000WM

    Additional Orenco Equipment Required for a Complete Installation:

    PVC Access Risers & Accessories: ................................... (1) RR30XXRLA+(5)10+(2)10-LACEY, (2) RR24XXRLA

    Fiberglass Access Lids: ..................................................... (1) FLF30G, (2) FLD24G

    Fiberglass Tank: ................................................................. (1) T8000-LACEY

    Service Connection Valve Assembly ................................. (1) SC125-LACEY

    For Customer Use: Site address:

    Lot number:

    Development:

    Installer: Install Date:

    Vendor:

    City Inspector:

    eandrewsText BoxJ-23

  • YPGW

    DWG. NO.

    DWN CKD DATE

    CITY ENGINEER

    APPROVED

    eandrewsText BoxJ-24

  • ADH100 AdhesiveGeneralADH100 is a single component opaque adhesive formulatedto bond PVC risers to Orenco grade rings and PRTA seriestank adapters. Upon curing, the seal created is both waterand chemical resistant.

    Standard ModelADH100

    Submittal Data Sheet

    SpecificationsGel time is approximately 10 minutes; ultimate bond strength occurs after 24 - 72 hours at 70˚ - 85˚ F. Cure time is increasedgreatly with a decrease in temperature; not recommended for use in temperatures below 32˚ F.

    Expected shelf life is approximately 5 years when stored at temperatures between 45˚ - 85˚ F.

    NSU-RLA-ADH-3Rev. 2.2, © 1/01

    ApplicationsADH100 is used to bond PVC risers to Orenco grade ringsand PRTA series tank adapters.

    eandrewsText BoxJ-25

  • Applications Orenco 84-inch Biotube® Pump Vaults are used to filter efflu-ent that is pumped from septic tanks or separate dosing tanks in STEP systems and onsite wastewater treatment systems. They remove two-thirds of suspended solids, on average. Pump vaults house a Biotube effluent filter and one or two Orenco high-head effluent pumps and can be used in single-compartment septic tanks with flows up to 40 gpm. When flows are greater than 40 gpm, a double-compartment septic tank or separate dosing tank is recommended.

    General The Orenco 84-inch Biotube Pump Vault includes a molded polyethylene housing with an internal filter cartridge con-structed of polypropylene and PVC. Schedule 80 PVC support pipes are included to suspend the vault in a tank opening. The filter cartridge can be removed without pulling the pump or the vault. Effluent enters through inlet holes around the perimeter of the Biotube vault and flows through the Biotubes to the external flow inducer. The external flow inducer accom-modates one or two pumps. Orenco Biotube Pump Vaults are covered by U.S. patents #4,439,323 and 5,492,635.

    Standard ModelsPVU84-3625-L.

    Nomenclature

    © 2012 Orenco Systems® Inc. NTD-PVU-LACEY-2Rev. 1.0, © 01/12

    Page 1 of 2

    84-inch Universal Biotube® Pump VaultsTechnical Data Sheet

    For use with Orenco 4-in. Submersible Effluent Pumps

    Materials of ConstructionSupport pipe: Schedule 80 PVCBiotube® vault: PolyethyleneBiotube cartridge: Polypropylene/PVCFloat stem: Schedule 40 PVCDrain valve ball: Polypropylene

    External flow inducer

    Inlet holes

    Side view

    Support pipe

    Support pipe length:L = Long support pipes for 30" riser

    Inlet hole height (inches)

    Cartridge height (inches)

    84 - 36 25PVU

    Vault height

    Universal Pump Vault

    - L

    eandrewsText BoxJ-26

  • DRAW

    N BY

    : CD

    Ore

    nco

    Syst

    ems

    Inco

    rpor

    ated

    RDa

    te:

    6/1/

    06

    CUST

    OM D

    RAW

    ING:

    REVI

    SION

    :1

    Instructions

    Installation Instruction

    X-STYLE VAULT INSTRUCTIONSPART# INSTR-X

    1" SCH. 40 PVCCUT LENGTH 48 3/4"

    18

    DO NOT GLUE JOINT

    USE REINFORCED TOP

    PVUP

    57-1

    819-

    L

    WOR

    K OR

    DER

    #

    APPR

    OVED

    BY:

    MAS

    TER:

    1391

    37

    3055

    73

    Universal Biotube® Pump Vaults (continued)Technical Data Sheet

    © 2012 Orenco Systems® Inc. NTD-PVU-LACEY-2Rev. 1.0, © 01/12

    Page 2 of 2

    SpecificationsModel PVU84-3625-LVault height (F) 84 in. Lowest float setting point (G) 38 in. Inlet hole height (H)* 25 in. Biotube® cartridge height (J) 36 in. Biotube mesh opening 0.125 in.Filter flow area 8.8 ft2 Filter surface area 29.0 ft2 Maximum flow rate 140 gpm

    * May vary depending on the configuration of the tank.

    Side view cutaway

    C

    D

    Top view

    Support pipes

    H

    F

    2" min.

    J

    G

    A

    B

    DimensionsA 3.0 in.B 4.0 in.C 17.3 in.D 16.6 in.E 12.0 in.

    Drain valve ball

    E

    eandrewsText BoxJ-27

  • Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-MF-MF-LACEY-2Rev. 2.0, © 01/18

    Page 1 of 2

    Float Switch AssembliesTechnical Data Sheet

    Applications Float switches are used to signal liquid level positions for alarm and pump control applications. Orenco float switch assemblies can be mounted in pump vaults, effluent screens, pump basins, and risers.

    GeneralAll models listed are UL listed and CSA certified for use in water or sewage.

    Floats are typically ordered in assemblies that include one or more floats mounted on a 1-inch PVC float stem. ABS float collars are used to provide secure mounting that is easily adjustable.

    Standard ModelsMFPGN-39V-50-LACEY

    Product Code Diagram

    Materials of ConstructionFloat housing Impact-resistant, noncorrosive PVC plastic for use in liquids up to 140˚ F

    Float cord Flexible 2-conductor (UL, CSA), SJOW; water-resistant (CPE); neoprene coating

    Float collar ABS

    MF 39 50VPGN LACEY- - -

    Application:V = pump vault (Lacey, WA float settings)

    Cod length:50 = 50 in.

    Stem length:39 = 39 in.

    Float switch models:P = signal-rated mechanical float switch, normally openG = motor-rated mercury float switch, normally openN = signal-rated mechanical float switch, normally closed

    Mechanical or mercury float switch assembly

    The “On” and “Off” positions describe normally open floats.

    On

    Off

    Float collar

    Float tether

    Set point

    Draw

    down

    X

    Y

    20"25"29"

    Float stem

    P

    G

    N

    eandrewsText BoxJ-28

  • Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-MF-MF-LACEY-2Rev. 2.0, © 01/18Page 2 of 2

    Technical Data Sheet

    Notes1 State: normally open or normally closed

    The default state of a float — normally open or normally closed — refers to the contact positions in the float when the float is resting (down). Float switches have an internal contact. The terms “normally open” (N/O) and “normally closed” (N/C) refer to the state of the float switch contact in the down position. A normally open float switch has an open contact (off) in the down position and a normally closed float switch has a closed contact (on) in the down position. Different panel functions require different types of float switches. Most applications require float switches that are normally open. One notable exception is the redundant off and low-level alarm function that requires a normally closed float switch, except with MVP and VCOM panels.2 Type

    Floats have mechanical or mercury contactor types. The important distinc-tion between these is that mercury floats are not rated for potable water.

    3 IR (intrinsically safe relay)

    Approved for use with intrinsically safe, Class I, Division 1 applications, where reliable float switch operation with very low current is required. 4 Drawdown

    Drawdown (in inches) refers to the difference in liquid level between a float switch’s activation and deactivation points. Drawdown can be altered by adjusting the tether length of the float switch cord. When selecting float switches, keep in mind that any float switch that can directly start and stop a pump (one that has no motor contactor in the control panel) should have a drawdown capability, to avoid rapid cycling of the pump.

    Float State1 Type2 IR3 Volts Amps hp Tether X Y Drawdown4

    Signal-rated mechanical floats (for control switch applications)

    P Model Normally open Mechanical Yes n/a n/a n/a 2.00 in. 1.50 in. 0.50 in. 2.0 in.

    N Model Normally closed Mechanical Yes n/a n/a n/a 2.00 in. 1.50 in. 0.50 in. 2.0 in.

    Motor-rated floats (for pump switch applications)

    G Model Normally open Mercury No 120 V 15A ¾ hp 2.00 in. 1.50 in. 3.00 in. 4.50 in.

    eandrewsText BoxJ-29

  • Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-HV-HV-LACEYRev. 2.0, © 01/18

    Page 1 of 1

    Discharge AssembliesTechnical Data Sheet

    Standard ModelsHV100BPRX-80-LACEY, PPSC-10

    Product Code Diagrams

    Materials of ConstructionComponent Material

    Ball valve Schedule 40 PVC

    Flowmatic check valve Stainless steel

    Pipe and fittings Schedule 80 PVC

    Flexible hose PVC

    External flex hose PVC

    Flow control disc Schedule 80 PVC

    Gate valve Schedule 80 PVC

    Unions Schedule 80 PVC

    High-pressure flex hose Special elastomer compound

    Component Working Pressure RatingsValves 150 psi (10 bar) at 73˚ F (23˚ C)

    Unions 150 psi (10 bar) at 73˚ F (23˚ C)

    High-Pressure Hose SpecificationsThickness and working pressures at 73˚ F (23˚C) Size Wall Working (Nominal) thickness pressure

    1.00 in. 0.235 in. 250 psi

    ApplicationsOrenco Discharge Assemblies are used to convey effluent from a pump to the exterior of a riser or pump basin. They come in high-head configuration, for use with submersible turbine pumps. An external flex extension is recommended for installations where tank settling may occur to avoid line breakage during settling. Discharge assemblies for use in 1500-gallon STEP tanks include a ¼-in. flow control orifice.

    GeneralOrenco Discharge Assemblies are corrosion-resistant and adjustable for a proper fit. Discharge assemblies are composed of PVC valves and flexible hose that simplify installation and maintenance. The flex-ible hose damps vibrations from the pump and allows for easy instal-lation. All parts are either solvent welded or threaded and sealed with Teflon® paste.

    Teflon® is a registered trademark of DuPont.

    HV PR 80100 LACEYB X

    Schedule 80

    Pump discharge assembly

    PR = High-pressure

    B = Ball valve

    X = External flex hose

    Discharge diameter:100 = 1-in.

    - -

    PP SC 10

    Discharge diameter10 = 1 in.

    Stainless steel check valve

    Pump part

    -

    Stainless Steel Check Valve

    Hose and Valve Assembly

    High-Pressure Hose

    eandrewsText BoxJ-30

  • Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-LACEY-2Rev. 1.0 © 01/18

    Page 1 of 2

    PF-Series 4-in. Submersible Effluent PumpTechnical Data Sheet

    ApplicationsOrenco® 4-in. Submersible Effluent Pumps are designed to transport screened effluent (with low TSS counts) from septic tanks or separate dosing tanks. All of our pumps are constructed of lightweight, corrosion-resistant stainless steel and engineered plastics; all are field-serviceable and repairable with common tools; and all standard 60-Hz PF Series models are CSA certified to the U.S. and Canadian safety standards for effluent pumps, meeting UL requirements.

    High-Head Effluent Pumps from Orenco® are used in a variety of applications, including pressurized drainfields, packed bed filters, mounds, aerobic units, effluent irrigation, effluent sewers, wetlands, lagoons, and more. These pumps are designed to be used with a Biotube® pump vault.

    Features/SpecificationsOrenco 4-in. Submersible Effluent Pump has the following features:

    • Minimum 24-hour run-dry capability (liquid end) with no deteriora-tion in pump life or performance

    • 1/8-in. bypass orifice (patent pending) to ensure flow recirculation for motor cooling and to prevent air bind

    • Liquid end repair kits available for better long-term cost of ownership

    • TRI-SEAL™ floating impeller design

    • Super stainless Franklin Electric motor, rated for continuous use and frequent cycling

    • Type SOOW 600-V motor cable (suitable for Class I, Division 1 and Division 2 applications)

    • Five-year warranty on pump or retrofit liquid end from date of manufacture against defects in materials or workmanship

    Standard ModelPF200512-50

    Product Code Diagram

    Discharge connection

    Bypass orifice

    Suction connection

    Fran

    klin

    liqui

    d en

    dFr

    ankli

    n su

    per s

    tain

    less

    mot

    or

    LR80980LR2053896

    PF 20 05 5021

    Cord length:50 = 50 ft

    PF-series 4-in. submersible effluent pump

    Horsepower:05 = 1/2 hp

    Nominal flow, gpm:05 = 1/2 hp

    Voltage, nameplate:2 = 230 VAC

    Frequency:1 = Single-phase, 60 Hz

    -

    eandrewsText BoxJ-31

  • Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-LACEY-2Rev. 1.0 © 01/18Page 2 of 2

    Technical Data Sheet

    SpecificationsDesign gpm (in.) 20

    Horsepower 0.50

    Phase 1

    Voltage, nameplate 230

    Voltage, actual 240

    Design flow amps 6.4

    Max amps 6.

    Impellers 4

    Discharge size1 1 1/4

    Length (in.) 22.5

    Min. liquid level2 (in.) 18

    Weight3 (lb) 32

    Rated cycles/day 3001 The 1 ¼-in. NPT discharge is 2 7⁄8-in. octagonal across flats; Discharge is female NPT threaded, U.S. nominal size, to accommodate Orenco® discharge hose and valve assemblies.

    2 Minimum liquid level is for single pumps when installed in an Orenco Biotube® Pump Vault or Universal Flow Inducer. In other applications, minimum liquid level should be top of pump. Consult Orenco for more information.

    3 Weight includes carton and 50-ft cord.

    Materials of Construction Discharge: Glass-filled polypropylene

    Discharge bearing: Engineered thermoplastic (PEEK)

    Diffusers: Glass-filled PPO (Noryl GFN3)

    Impellers: Celcon® acetal copolymer

    Intake screen: Polypropylene

    Suction connection: Stainless steel

    Drive shaft: 7/16 inch hexagonal stainless steel, 300 series

    Coupling: Sintered stainless steel, 300 series

    Shell: Stainless steel, 300 series

    Motor: Franklin motor exterior constructed of stainless steel. Motor filled with deionized water and propylene glycol for constant lubrication. Hermetically sealed motor housing ensures moisture-free windings. All thrust absorbed by Kingsbury-type thrust bearing. Rated for continuous duty. Protected against thermal overload and equipped with surge arrestors for added security.

    Tota

    l dyn

    amic

    hea

    d (T

    DH) i

    n fe

    etFlow in gallons per minute (gpm)

    142 4 6 8 10 16 18 20 22 24 26 28 30120

    20

    0

    40

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    280

    300

    PF Series 60-Hz 0.5 hp

    PF200512

    Using a Pump CurveA pump curve helps you determine the best pump for your system. Pump curves show the relationship between flow (gpm) and pres-sure (total dynamic head, or TDH), providing a graphical represen-tation of a pump’s optimal performance range. Pumps perform best at their nominal flow rate — the value, measured in gpm, expressed by the first two numerals in an Orenco pump nomencla-ture. At low flow rates, TDH varies from pump to pump, so it is rep-resented as a dashed line in the pump curves. For most accurate pump specification, use Orenco’s PumpSelect™ software.

    eandrewsText BoxJ-32

  • Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-CP-D-LACEY-3Rev. 1.0, © 01/18

    Page 1 of 1

    Duplex Control Panel Package – Lacey, WATechnical Data Sheet

    ApplicationsOrenco® Duplex Control (DAX) Panels are used to control effluent pumps, alarms, and other equipment as specified in pressure sewers and onsite systems.

    GeneralOrenco Duplex Control Panels are specifically engineered for pressure sewer (STEP) systems, onsite septic treatment systems, and pump con-trol into gravity sewer systems. Standard features include circuit break-ers, and automatic/manual/off toggle switch, automatic motor control operation, and an audible/visible high water level alarm with auto reset.

    Standard ModelsDAX2IRFL-LACEY-FS, DAX2IRFL-LACEY-WM

    Product Code Diagram

    Enclosure Dimensions FS FS WM Isolation Disconnect Enclosure Pedestal Enclosure Enclosure Enclosure

    Height (in.) 36 10 30 20 9

    Width (in.) 18 18 21 20 5.5

    Depth (in.) 12 12 12 8 2

    SpecificationsEnclosure, FS models Strong Box® model B18SS; pedestal model PED-18SS

    Enclosure, WM models Fiberglass, Type 4X

    Enclosure, Isolation Stainless steel, Type 4X

    Enclosure, Disconnect Galvanized steel, type 3R, UL 98 rated

    Panel Ratings 240 V, 2 hp, 28 A, single phase, 60 Hz

    Motor-Start Contactors 240 V, 28 FLA, 3 hp, 60 hz; 2.5 million cycles at FLA (10 million at 50% of FLA)

    Intrinsically Safe Relays 5-channel, 100/240 VAC, UL 698 listed

    Duplex Alternator Cross wired style for independent lag pump function; Selector switch for locking one pump into lead position

    Controls Circuit Breaker 10 A, OFF/ON switch; Single-pole 120 V; DIN rail mounting with thermal magnetic tripping characteristics

    Pump Circuit Breakers 20 A, OFF/ON switches; Double-pole 240 V; DIN rail mounting with thermal magnetic tripping characteristics

    Toggle Switches Single-pole, double-throw HOA switches; 20 A, 1hp

    Audible Alarm 95 dB at 24 in., warble-tone sound

    Visual Alarm 7⁄8-in. diameter red lens, “Push-to-silence;” UL Type 4X rated, 1 W LED light, 120 V

    Flashing light 4-in height, 3-in. diameter, UL Type 4X rated, 13 W LED light, 120 V

    Redundant Off Relay Provides a secondary off; Sounds alarm on low level condition; DIN rail mount

    Disconnect Switch 3-pole, 60 A, 600 V, UL 98 rated

    DAX2 DSRO LACEYIR FL

    Flashing light

    Intrinsically safe relays

    Duplex panel, 240 VAC

    Mounting option:FS = Free-standing panel packageWM = Wall-mounted panel package

    Panel option:DS = Disconnect switch

    Panel option:RO = Redunat-off/low-level alarm

    - -

    eandrewsText BoxJ-33

  • Panel Wiring DiagramModel DAX2 IR RO DS FL - LACEY

    2017 SUBMITTAL

    CB 10A

    1.1

    1.2

    1.3

    1.4

    1.5

    1.6

    1.7

    1.8

    1.9

    1.10

    1.11

    1.12

    1.13

    1.14

    1.15

    1.16

    1.17

    1.18

    1.19

    1.20

    1.21

    1.22

    1.23

    1.24

    1.25

    1.27

    1.28

    Ground

    N

    L2

    L1

    DISCONNECTSWITCH

    60A

    L1

    M1

    T2L2

    T1L1

    M2

    T2L2

    T1L1

    Note: Motors must haveinternal overload protection

    Pumps230 VAC / 1 Hp.1 Phase / 60 Hz.

    = Factory Wire= Field Wire

    L2

    NCB 15A

    CB 15A

    INTRINSICALLYSAFE RELAYIDEC EB3C-R05A

    Floats or equivalent devicesmust be purely resistive and

    non-energy storing

    Maximum cable length frompanel to float is 2,000 feet

    Install in accordance with Article504 of the National Electric

    Code

    Note: A spacing of 2 inches(50mm) must be maintained

    between intrinsically safe, andnon-intrinsically safe wiring.

    From Main Power Panel240/120 VAC, 1 Phase, 60 Hz.

    Main disconnectprovided by others.

    PUSH TO SILENCE

    NB(OPTIONAL)

    CABINET BEACON ALARM LIGHT

    AL1

    SRA2A1

    AUDIBLE ALARM FLOYD BELL SP-1081A -+

    SR 1411

    SR 1211

    LOCAL PUSHBUTTON LEVEL ALARM LIGHTIDEC HW SERIES

    RX2X1

    ALARM SILENCE RELAYIDECRJ2S-CL-A120

    AL1

    IR A5C5

    CR1 2421

    IntrinsicallySafe Section

    Non-IntrinsicallySafe Section

    Lead PumpOn

    Redundant Off/Low Level Alarm

    High LevelAlarm

    IR

    L

    P1 P2 P3 P4 P5 N5

    N

    TL*

    LATCING RELAYIDEC RJ2S-CL-A120CR2

    A2A1

    NRRemote Alarm

    Light Alarm

    ORENCO AHW REMOTE ALARM BOX(SEE DETAIL ON LEFT)

    AL

    RA2A1

    AA-+

    R 1411

    R 1211

    ALX2X1

    AL

    ORENCO AHWDETAIL

    TL: The installed terminal linkcombines the Lag Pump Onoperation with the High Level

    Alarm float. To separate,remove the terminal link.

    BL

    NR

    999594939291

    999594939291

    Isolation PedestalEnclosure

    Isolation PedestalEnclosure

    1

    2

    3

    4

    1

    2

    3

    4

    1

    2

    eandrewsText BoxJ-23

    eandrewsText BoxJ-34

  • 1.28

    Simplex Operation

    High Level Alarm- Lag Pump On/Off: This float activates the alarm light and audible alarm when lifted. The audible alarm may be silenced by pressing the PUSH TO SILENCE button. The alarm light will remain on until the float is lowered.

    This float also turns on the Lag Pump. The pump will remain on until the Lag and Lead floats are lowered.

    Lead Pump On/Off: This float turns on the Lead Pump when lifted. The pump will continue to run until the float is lowered.

    Redundant Off/Low Level Alarm: This float activates the alarm light and audible alarm when lowered. The audible alarm may be silenced by pressing the PUSH TO SILENCE button. The alarm light will remain on until the float is raised. The pumps will not operate during low level alarm.

    2.1

    2.2

    2.3

    2.4

    2.5

    2.6

    2.7

    2.8

    2.9

    2.10

    2.11

    2.12

    2.13

    2.14

    2.15

    2.16

    2.17

    2.18

    2.19

    2.20

    2.21

    2.22

    2.23

    2.24

    2.25

    2.27

    2.28

    ALTERNATING RELAYSSAC ARP43S

    ALT

    ALT

    63

    72

    81

    OFFHAND AUTO

    OFFHAND AUTO

    M11314

    M21314

    M1A2A1

    MOTOR CONTACTORABB A16-30-10-84

    M2A2A1

    MOTOR CONTACTORABB A16-30-10-84

    CR1A2A1

    IR A1C1 REDUNDANT OFF RELAYIDECRJ2S-CL-A120

    CR1 1211 IR A4C4

    IR A3C3

    IRA2C2

    eandrewsText BoxJ-35

  • Control PanelEnclosure: Schneider NSYPLM75G

    PANEL FRONT30 x 21

    PUSH TO SILENCE

    MOUNTING PANEL

    AUTO

    OFF

    MAN

    AUTO

    OFF

    MAN

    Relay IdecEB3C-R05A

    EE

    Ju

    sti

    n W

    hit

    ed

    1

    of

    1

    Mo

    de

    l D

    AX

    2 I

    R R

    O D

    S F

    L

    - L

    AC

    EY

    06

    /08

    /17

    1.0

    Dra

    win

    g N

    o.

    Da

    te:

    Title

    :

    Da

    te A

    pp

    rove

    d:

    Ap

    pro

    ved

    By:

    De

    sig

    ne

    d B

    y:

    Dra

    win

    g:

    Dra

    wn

    By:

    Re

    visi

    on

    :S

    cale

    :N

    on

    e0

    6/0

    8/1

    7

    EE

    SU

    BM

    ITT

    AL

    Q#

    06

    02

    17

    JS

    2

    OT60F3

    l ON

    O

    OFF

    2T1 4T2 6T3

    1L1 3L2 5L3

    Alarm

    Cutler HamCircuit Breakers

    Idec RelayRJ2S-CL-A120

    LLCABB

    LLC44A1A

    10

    0n/I

    0ff/

    O

    0n/I

    0ff/

    O

    0n/I

    0ff/

    O

    20

    0n/I

    0ff/

    O

    0n/I

    0ff/

    O

    20

    ABBMotor Contactors

    ABBDisconnect Switch

    Wire Tray

    Wire Tray

    IntrinsicallySafe Area

    J-36

  • Control PanelEnclosure: Rittal WM202008N6

    PANEL FRONT20 x 20 MOUNTING PANEL

    EEJu

    stin

    Whi

    ted

    1 o

    f 1

    Isol

    atio

    n P

    edes

    tal

    06/2

    3/17

    1.0

    Dra

    win

    g N

    o.

    Dat

    e:

    Title

    :

    Dat

    e A

    ppro

    ved:

    App

    rove

    d B

    y:

    Des

    igne

    d B

    y:

    Dra

    win

    g:

    Dra

    wn

    By:

    Rev

    isio

    n:S

    cale

    :N

    one

    06/2

    3/17

    EES

    UB

    MIT

    TAL

    IntrinsicallySafe Area

    95-H

    igh

    Leve

    l/La

    g O

    n

    Pump 1 Pump 2

    TL TL TL TL TL

    95 9993 9491 92

    99-C

    omm

    on

    93-L

    ead

    On

    91-R

    O/

    Low

    Lev

    el

    1 2 3 4

    TL

    eandrewsText BoxJ-37

  • Quote #: 060217JS2.2

    Model: DAX2 IR RO DS FL- LACEY (Fiberglass Version)

    10 Digit Manf Number Manufacturer Description QtyParts List

    Project: City of Lacey 2017 Standard

    Audible Alarms13-16-56-1029 SP-1081 Floyd Bell Alarm; 120V, 95db, Reduced Sensitivity, Extra Fast Warble,

    Panel Mount1

    Circuit Breakers13-16-11-1014 QCR1010 Cutler Ham Circuit Breaker; 10A, 1P, 120/240V 113-16-11-1020 QCR2020 Cutler Ham Circuit Breaker; 20A, 2P, 120/240V 2Control Switches13-16-66-1034 XTD2B1ABP Eaton Switch; Toggle, 1PDT, On-Off-On, .250 Spade Terminals, 20

    Amps @ 125 VAC2

    Disconnect SwitchesXX-XX-XX-USER

    DPU222R Eaton Pull-Out Disconnect Switch, 60A 2Pole 113-16-66-1376 OT60F3 (Old# OT60E3) ABB Disconnect Switch; 60A, 600V, 3-Pole, UL98 113-16-66-1350 OHYS2AJ1 (Old#

    OHY2AJ1)ABB Disconnect Handle; Red/Yellow, 100A, Type 3R 1

    13-16-66-1356 OXS6X250 (Old#OXS5X250)

    ABB Disconnect Shaft; 9.8", 100A 1EnclosuresXX-XX-XX-USER

    WM202008N6 Rittal 316SS Wallmount Enclosure, 20x20x8 113-21-11-1337 NSYPLM75G Schneider Enclosure; 30x21x12, Small, Fiberglass, Type4X 113-21-11-1171 OSI-BP3021A Orenco Sys Backplate; Aluminum, for NSYPLM75 30x21enclosure 113-16-99-1012 C-107-PM Cust. Con. DIN Rail; 1 meter, pre-punched, aluminum .7Lights13-16-36-1500 HW1L-M2F10QD-R-120V Idec Pushbutton; Red, Illuminated, 120V, Complete 113-16-36-1178 AMX15 Ingram Dome Light; Mini, Red, 15W, 120V, Type 4X 113-16-36-1194 SSF150W Ingram Alarm Light; Solid State Flasher SSF150W 1MiscXX-XX-XX-USER

    PSTPS500EH10Ss Platt 14GA 316SS Unistrut 10FT 1XX-XX-XX-USER

    1300990462 Woodhead Non Metallic Relief with Mesh 5XX-XX-XX-USER

    Misc-Alum Barrier Orenco Aluminum Barrier for Main Panel 1XX-XX-XX-USER

    Misc-Alum2 Orenco Aluminum Barrier For Isolation Pedistal Box 1XX-XX-XX-USER

    5602 Woodhead Locknut for 1300990162 5XX-XX-XX-USER

    5612 Woodhead Gasket Seal For 1300990162 5XX-XX-XX-USER

    1301800333 Woodhead O Ring For 1300990161 5Motor Contactors/Starters13-16-16-1304 AX18-30-10-84 ABB Contactor; 18A, 3P, 110 - 120V, 50/60 HZ 2Relays13-16-46-1073 RJ2S-CL-A120 Idec Relay; 120V, DPDT, 8A, Indicator 313-16-46-1283 SJ2S-07LW Idec Socket; 8 Pin, DIN/Pnl Mt, for RJ Relays 313-16-46-1116 EB3C-R05AN Idec Relay; Intrinsic barrier, 5 channel, 100/240v AC, UL listed 113-16-46-1160 ARP 43S Littelfuse Relay; Alternating, 120V, DPDT, 8-Pin, Selector 113-16-46-1290 SR2P-05C Idec Socket; 8-Pin, 2P, 300V, Touch Safe 1Terminal Blocks13-16-71-1450 3044131 (UT-6) Phoenix Terminal Block; 24/8AWG, 50A, 1P, 1000V, 8.2mm 1013-16-71-1480 0800886 Phoenix Terminal Block; End Block, ENS 35N 213-16-71-1490 3003020 Phoenix End Cover; D-UK 4/10 (UK 5 & 6) 113-16-71-1502 0200059 Phoenix Jumper; 3-Pole, UK6 1XX-XX-XX-5563 misc Phoenix PHO Number 10

    eandrewsText BoxJ-38

  • Air Conditioning DisconnectsFused and Non-Fused Pullouts• ON/OFF control provided by a

    pullout handle

    • Pullout handle can be conve-niently stored in the compart-ment in the OFF position,helping to prevent the handlefrom being misplaced

    • Protective shield cannot beremoved until the pullouthandle is removed,disconnecting the power

    Molded Case Switch• Rugged molded case

    construction in a disconnectswitch that looks like a circuitbreaker but operates likean ordinary household lightswitch

    • Plug-in molded case switch(included) eliminates the needfor pullout handles

    • No need for replacementpullout handles due to lossor theft

    Eaton’s product offering:• 3 Standard Designs:

    • Non-Fused

    • Fused

    • Molded Case Switch

    • Enclosure:

    • NEMA 3R (outdoor)

    • Metallic (galvanized/painted)

    • Non-metallic (plastic)

    • Ratings:

    • Single-phase, two-wire,240Vac

    • Three-phase, three-wire,240Vac

    • 30 and 60 amps

    • Optional ACDs with GroundFault Receptacles or Weather-Resistant/Tamper-ResistantReceptacles are available

    Eaton Air Conditioning Disconnects

    Air Conditioning Disconnects (ACD) are located between a loadcenter (distribution panel) and an air conditioner. ACDs provide a visible disconnecting means when perform-ing maintenance and are commonly referred to as disconnects, pullouts or air conditioning switches.

    Applications: • Air conditioners

    • Heat pumps

    • Water heaters

    • Other locations where a localdisconnect is required

    eandrewsText BoxJ-39

  • Eaton CorporationElectrical Sector1111 Superior Ave.Cleveland, OH 44114United States877-ETN-CARE (877-386-2273)Eaton.com

    © 2012 Eaton CorporationAll Rights ReservedPrinted in USAPublication No. PA00701002EFebruary 2012

    All other trademarks are property of their respective owners.

    Non Fused Pullouts

    Max. hp rating

    Main Ampere Rating 120V 240V

    Wire Size Range Cu/Al 60C or 75C Catalog Number

    Galvanized Steel

    60 - 10 #14-3 DPU222R

    Non-Metallic/Polycarbonate Enclosure

    60 - 10 #14-2 ACD222URNM-A2

    Fused Pullouts

    Max. hp rating

    Main Ampere Rating 120V 240V

    Wire Size Range Cu/Al 60C or 75C Catalog Number

    Galvanized Steel

    30* 2 3 #14-3 DPF221R

    60* 3 10 #14-3 DPF222R

    Non-Metallic

    30 2 3 #14-2 ACD221RNM-A2

    60 3 10 #14-2 ACD222RNM-A2

    Molded Case Switch

    Max. hp rating

    Main Ampere Rating 120V 240V

    Wire Size Range Cu/Al 60C or 75C Catalog Number

    Galvanized Steel

    60 - 10 #14-3 DPB222R

    Non-Metallic/Polycarbonate Enclosure

    60 - 10 #14-2 B60NARNM-A2

    Three-Phase Non-Fused ACD

    Max. hp rating

    Main Ampere Rating 240V 480V Wire Size Range Cu 75C Catalog Number

    Galvanized Steel

    60 15 30 #14-4 DPU362RA

    ACD with 20 Ampere Ground Fault Receptacle

    Max. hp rating

    Main Ampere Rating 120V 240V

    Wire Size Range Cu/Al 60C or 75C Catalog Number

    Non-Fused Pullouts

    60 - 10 #14-3 DPU222RGF20WRTR

    60 - 10 #14-3 DPU222RGF20

    Fused Pullouts

    30 2 3 #14-3 DPF221RGF20WRTR

    30 2 3 #14-3 DPF221RGF20

    60 3 10 #14-3 DPF222RGF20WRTR

    60 3 10 #14-3 DPF222RGF20

    ACD with 15 Ampere Ground Fault Receptacle

    Max. hp rating

    Main Ampere Rating 120V 240V

    Wire Size Range Cu/Al 60C or 75C Catalog Number

    Non-Fused Pullouts

    60 - 10 #14-3 DPU222RGF15WRTR

    60 - 10 #14-3 DPU222RGF15

    Fused Pullouts

    30 2 3 #14-3 DPF221RGF15WRTR

    30 2 3 #14-3 DPF221RGF15

    60 3 10 #14-3 DPF222RGF15WRTR

    60 3 10 #14-3 DPF222RGF15

    *To obtain a Service Entrance rating, the addition of a ground bar kit is required.

    eandrewsText BoxJ-40

  • © 2009 Orenco Systems® Inc. NTD-RLA-RR-LACEYRev. 1.0, © 6/09

    Page1 of 1

    Access Risers Technical Data Sheet

    GeneralOrenco Access Risers are constructed of ribbed PVC pipe and are available in 24-in. and 30-in. diameters. The 24-in. ribbed ris-ers are available in three-inch increments up to 14 ft in length. The 30-in. risers are available in one-inch increments up to 13 ft in length.

    Standard ModelsRR24XX, RR30XX

    Nomenclature

    ApplicationsOrenco’s Access Risers provide access to septic tank openings and can be cast into the tops of concrete tanks, bonded in place, or bolted down using a riser tank adaptor. They can also be used as valve enclosures.

    Materials of ConstructionRibbed Risers: PVCBolt catch (30" risers only) PVC

    SpecificationsModel RR24XX RR30XXI.D. (in.) 23.50 29.50Wall Thickness - excluding ribs (in.) 0.20 0.20O.D. - including ribs (in.) 25.63 31.00Weight per foot (lb) 19 18

    Riser diameter:24 = 24 in. 30 = 30 in.

    Riser height, inches

    Ribbed riser

    RR

    eandrewsText BoxJ-41

  • © 2008 Orenco Systems® Inc. NTD-RLA-RLA-LACEYRev. 1.0, © 6/09

    Page 1 of 1

    RLA Riser-to-Lid AdaptersTechnical Data Sheet

    ApplicationsOrenco® riser-to-lid adapters (RLAs) provide a secure, water-tight method of attaching an Orenco fiberglass lid to a 24-in. or 30-in. ribbed PVC access riser.

    RLAs are especially useful when the top of the riser is uneven or has a damaged edge.

    GeneralRLA adapters can be attached to 24-in. or 30-in. risers to sim-plify bolting a lid to the riser.

    Standard ModelsRLA24, RLA30

    Nomenclature

    Materials of ConstructionAdapter ABSO-ring EPDM SpecificationsDimensions in inches (mm) RLA24 RLA30

    A – Adapter height 1� (32) 1� (32)

    B – Socket or lip width 1 (25) 1 (25)

    C – Inside diameter 227⁄8 (581) 28⇥ (724)

    D – Outside diameter 25⇥ (648) 31 (787)

    E – Socket depth 3⁄8 (10) N/A

    Riser style Perma-Loc™ Perma-Loc Ultra-Rib™

    Lid bolt

    RLA24 adapter

    24-in. riser

    Fiberglass lid

    RLA24 riser-to-lid adapter

    DC

    A

    BE

    RLA30 riser-to-lid adapter

    30-in. riser

    Lid bolt

    RLA30 adapter

    Fiberglass lid

    DC

    A

    B

    RLA

    Riser-to-lid adapter

    Adapter diameter (inches):24 = 24"30 = 30"

    eandrewsText BoxJ-42

  • Pipe GrommetsGeneralOrenco Pipe Grommets are constructed of corrosion-resistant rub-ber to provide long-lasting seals. Grommets conform to standardIPS sizes. Not all models conform exactly to the depiction shown.

    Standard ModelsG05L, G075L, G1L, G125L, G150L, G2L, G3L, G4L, G6L

    Nomenclature

    Submittal Data Sheet

    ODID

    GW

    GD

    T

    SpecificationsDimensionsModel G05L G075L G1L G125L G150L G2L G3L G4L G6LOD (inches) 1 1/4 1 1/2 1 7/8 2 1/8 2 1/2 3 7/8 5 6 8 1/8ID (inches) 3/4 1 1 1/4 1 1/2 1 3/4 2 1/8 3 1/4 4 3/16 6 11/16GD (inches) 1 1 1/4 1 5/8 1 3/4 2 1/8 2 11/16 3 13/16 4 15/16 7 5/8GW (inches) 3/16 3/16 1/4 1/4 1/4 5/16 5/16 1/4 1/4T (inches) 1/2 7/16 9/16 5/8 5/8 15/16 15/16 7/8 13/16Holesaw Size (inches) 1 1 1/4 1 9/16 1 3/4 2 1/8 2 3/4 3 7/8 5 7

    Material of Construction:

    EPDM synthetic rubber in accordance with MIL-STD-417, 60 durometer.

    NSU-RLA-PG-1Rev. 3.4, © 7/03

    ApplicationsOrenco Pipe Grommets are used to provide a seal to prevent thepassage of liquids through pipe ports.

    G

    Indicates grommet diameter:05 = 1/2"075 = 3/4"1 = 1"125 = 1-1/4"150 = 1-1/2"2 = 2"3 = 3"4 = 4"6 = 6"

    Grommet

    LIndicates not installed

    eandrewsText BoxJ-43

  • Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-RLA-FL-5Rev. 2.0, © 03/17

    Page 1 of 1

    FLF-Series Fiberglass Access LidsTechnical Data Sheet

    ApplicationsOrenco® FLF-Series Fiberglass Access Lids provide a secure cover-ing for risers, pump basins, and access ports. They are capable of supporting a 2500-lb (1134-kg) wheel load; however, they are not designed or recommended for vehicular traffic. FLF-series lids will fit directly onto the riser types listed in the Specifications section.

    FLF30 lids are required for retrofits on 30-in. (750-mm) Perma-Loc™ access risers or 30-inch (750-mm) Orenco RLA riser-to-lid adapters.

    GeneralOrenco FLF-Series Fiberglass Access Lids are molded using fiberglass reinforced polyester resin with a structural foam core for added dura-bility and longevity. The finish is green or brown and the top surface is textured to provide a nonskid surface. Gasketed lids include a polyurethane gasket. FLF Lids come with four 5⁄16-inch stainless steel flathead socket cap screws and a hex key wrench.

    Standard ModelsFLF18G, FLF21G, FLF30G

    Product Code Diagram

    Materials of ConstructionLid Fiberglass

    Core Structural foam

    Gasket Polyurethane

    SpecificationsModel FLF18G FLF21G FLF30G

    Lid O.D. in. (mm) 20.25 (514) 22.5 (572) 32.6 (829)

    Groove I.D. in. (mm) 17.50 (445) 20.25 (514) 28.75 (730)

    Avg. thickness in. (mm) 0.75 (19) 0.75 (19) 1.0 (25)

    Weight lb (kg) 4.15 (1.8) 6.25 (2.8) 11.50 (5.2)

    Applications Ultra-Rib™ Ultra-Rib Perma-Loc™ Perma-Loc Kor Flo™

    BottomTop

    Cutaway view

    Core Groove I.D. Gasket Lid O.D.

    FLF

    Color and logo options:Blank = green color lidB = brown color lidC = custom logoATX = AdvanTex® logo

    Lid options:G = gasketV = ventCF = carbon filter installed in lidI2 = 2-in. (50-mm) insulation*I4 = 4-in. (100-mm) insulation

    -

    Lid diameter, in. (mm):18 = 18 (450)21 = 21 (525)30 = 30 (750)

    Fiberglass lid, FLF-series

    * Lid insulation has an R-value of 10 per 2-inch (50-mm) incrementNote: For fiberglass basin bottoms without holes, order FLF18 or FLF21

    eandrewsText BoxJ-44

  • Technical Data Sheet

    Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-RLA-FL-4Rev. 3.0, © 10/17

    Page 1 of 1

    DuraFiber™ Access LidsApplicationsOrenco® DuraFiber™ Access Lids provide a secure, damage-resistant covering for ribbed PVC and HDPE risers, pump basins, and access ports. They are not recommended for vehicular traffic. 24-inch (600-mm) DuraFiber lids require an RLA24 adapter to mate to 24-inch (600-mm) Perma-Loc™ pipe. 30-inch (750-mm) DuraFiber lids are not compatible with 30-inch (750-mm) RLA Riser-Lid-Adapters or 30-inch (750-mm) Perma-Loc pipe. For these products, use Orenco’s FLF-Series lids.

    GeneralDuraFiber Access Lids are constructed of resin-infused fiberglass fabrics for extreme durability and damage resistance, with breaking strengths in excess of 20,000 pounds (9,000 kg).

    They feature flat-style flanges for easier access, allowing clean, flush-to-grade installations. They have cored centering rings for aligning lids with risers. They also have urethane gaskets to help provide watertight seals.

    DuraFiber Lids feature a non-skid surface for better grip and aesthet-ics, a molded-in caution statement, and room for a customer logo. They come with four 5⁄16-inch stainless steel flathead socket cap screws and a hex key wrench.

    Durafiber Lids are available with optional insulation, installed at the fac-tory or in kits that can be installed in the field.

    Standard ModelsFLD24G, FLD24GATX, FLD24GW, FLD30G, FLD30GATX, FLD30GW

    Product Code Diagram FLD

    Insulation:*Blank = no insulationI2 = 2-inch (50-mm) insulation installedI4 = 4-inch (100-mm) insulation installed

    Vent and filter options:Blank = no vent or filter optionsV = ventCF = carbon filter

    Gasket options:G = gasket (standard) Blank = no gasket

    Lid diameter, in. (mm):24 = 24 (600)30 = 30 (750)

    DuraFiber™ fiberglass lid

    * Insulation has an R-value of 10 per 2-inch (50-mm) increment.

    Color and logo options:Blank = green color lidB = brown color lidC = custom logoATX = AdvanTex® logoW = warning label

    Materials of Construction:Lid Fiberglass reinforced polyester

    Gasket Urethane

    Centering ring core Structural foam

    Mounting hardware Stainless steel

    Insulation (optional) Closed-cell foam

    Insulation mounting hardware Stainless steel

    Specifications Model FLD24XX FLD30XX

    A in. (mm) 26 (660) 33 (838)

    B, in. (mm) 1½ (38) 1½ (38)

    C, in. (mm) 23¼ (590) 29¼ (743)

    Gasket width, in. (mm) ¾ (19) ¾ (19)

    Bolt hole diameter, in. (mm) 5⁄16 (8) 5⁄16 (8)

    Weight, lbs (kg) 11 (5) 20 (9)

    Bolt holes, per lid 4 4

    B

    A

    C

    eandrewsText BoxJ-45

  • © 2009 Orenco Systems® Inc. NTD-SC-LACEYRev. 1.0, © 6/09

    Page 1 of 1

    Service ConnectionsTechnical Data Sheet

    Applications Orenco® Service Connections are used to isolate pressure mainlines from individual service laterals, by combining a ball valve and check valve into one component. Service connections also help simplify inspection and maintenance procedures.

    General Orenco’s Service Connections are constructed of Schedule 80 PVC. All models built for the City of Lacey, WA include a 1-in. diameter inlet elbow and a 1 1/4-in. diameter outlet elbow.

    Standard ModelsSC125-LACEY

    Nomenclature

    Materials of ConstructionPipe Schedule 80 PVCFittings Schedule 80 PVCCheck valve (KBI) Schedule 80 PVCBall valve (KBI) Schedule 80 PVC

    SpecificationsA - Width (in.) 3.75B - Overall length (in.) 18.63C - Height (in.) 5.75Inlet diameter (IPS nom.) 1 in.Outlet diameter (IPS nom.) 1.25 in.

    Discharge diameter:125 = 1¼ in.

    Service connection

    125SC - LACEYA

    B

    C

    eandrewsText BoxJ-46

  • NCF-CO-LACEY8000FS Rev. 1.0, 08/17

    CERTIFICATE OF ORIGIN CITY OF LACEY

    Engineered wastewater collection system SMALL COMMUNITY SYSTEM

    (Using 8000 Gallon Tank & Free Standing (FS) Control Panel) The following Collection System On-Lot Package is certified to have been manufactured by Orenco Systems®, Inc., Sutherlin, Oregon. The On-Lot Package equipment listed below is covered by an extended factory warranty under the terms and conditions of Orenco Systems’ Certificated Products Limited Warranty in effect at the time of sale.

    On-Lot Package Code: PSA20-LACEY8000FS

    Adhesive: ........................................................................... (4) ADH100

    Biotube® Pump Vault: ........................................................ (1) PVU84-3625-L

    Float Assembly: .................................................................. (1) MFPGN-39V-50-LACEY

    Discharge Assembly: ......................................................... (2) HV100BPRX-80-LACEY

    Check Valve: ...................................................................... (2) PPSC-10

    Effluent Pump: .................................................................... (2) PF200512-50

    Control Panel: .................................................................... (1) DAX2IRRODSFL-LACEY-FS

    Homeowner’s Manual: ....................................................... (1) PMHOMEMANUAL

    Installation Manual: ............................................................ (1) PMPSPPINST

    Certificate of Origin: .......................................................... (1) NCF-CO-LACEY8000FS

    Additional Orenco Equipment Required for a Complete Installation:

    PVC Access Risers & Accessories: ................................... (1) RR30XXRLA+(5)10+(2)10-LACEY, (2) RR24XXRLA

    Fiberglass Access Lids: ..................................................... 1) FLF30G, (2) FLD24G

    Fiberglass Tank: ................................................................. (1) T8000-LACEY

    Service Connection Valve Assembly ................................. (1) SC125-LACEY

    For Customer Use:

    Site address:

    Lot number:

    Development:

    Installer: Install Date:

    Vendor:

    City Inspector:

    eandrewsText BoxJ-47

  • YPGW

    DWG. NO.

    DWN CKD DATE

    CITY ENGINEER

    APPROVED

    eandrewsText BoxJ-48

  • ADH100 AdhesiveGeneralADH100 is a single component opaque adhesive formulatedto bond PVC risers to Orenco grade rings and PRTA seriestank adapters. Upon curing, the seal created is both waterand chemical resistant.

    Standard ModelADH100

    Submittal Data Sheet

    SpecificationsGel time is approximately 10 minutes; ultimate bond strength occurs after 24 - 72 hours at 70˚ - 85˚ F. Cure time is increasedgreatly with a decrease in temperature; not recommended for use in temperatures below 32˚ F.

    Expected shelf life is approximately 5 years when stored at temperatures between 45˚ - 85˚ F.

    NSU-RLA-ADH-3Rev. 2.2, © 1/01

    ApplicationsADH100 is used to bond PVC risers to Orenco grade ringsand PRTA series tank adapters.

    eandrewsText BoxJ-49

  • Applications Orenco 84-inch Biotube® Pump Vaults are used to filter efflu-ent that is pumped from septic tanks or separate dosing tanks in STEP systems and onsite wastewater treatment systems. They remove two-thirds of suspended solids, on average. Pump vaults house a Biotube effluent filter and one or two Orenco high-head effluent pumps and can be used in single-compartment septic tanks with flows up to 40 gpm. When flows are greater than 40 gpm, a double-compartment septic tank or separate dosing tank is recommended.

    General The Orenco 84-inch Biotube Pump Vault includes a molded polyethylene housing with an internal filter cartridge con-structed of polypropylene and PVC. Schedule 80 PVC support pipes are included to suspend the vault in a tank opening. The filter cartridge can be removed without pulling the pump or the vault. Effluent enters through inlet holes around the perimeter of the Biotube vault and flows through the Biotubes to the external flow inducer. The external flow inducer accom-modates one or two pumps. Orenco Biotube Pump Vaults are covered by U.S. patents #4,439,323 and 5,492,635.

    Standard ModelsPVU84-3625-L.

    Nomenclature

    © 2012 Orenco Systems® Inc. NTD-PVU-LACEY-2Rev. 1.0, © 01/12

    Page 1 of 2

    84-inch Universal Biotube® Pump VaultsTechnical Data Sheet

    For use with Orenco 4-in. Submersible Effluent Pumps

    Materials of ConstructionSupport pipe: Schedule 80 PVCBiotube® vault: PolyethyleneBiotube cartridge: Polypropylene/PVCFloat stem: Schedule 40 PVCDrain valve ball: Polypropylene

    External flow inducer

    Inlet holes

    Side view

    Support pipe

    Support pipe length:L = Long support pipes for 30" riser

    Inlet hole height (inches)

    Cartridge height (inches)

    84 - 36 25PVU

    Vault height

    Universal Pump Vault

    - L

    eandrewsText BoxJ-50

  • DRAW

    N BY

    : CD

    Ore

    nco

    Syst

    ems

    Inco

    rpor

    ated

    RDa

    te:

    6/1/

    06

    CUST

    OM D

    RAW

    ING:

    REVI

    SION

    :1

    Instructions

    Installation Instruction

    X-STYLE VAULT INSTRUCTIONSPART# INSTR-X

    1" SCH. 40 PVCCUT LENGTH 48 3/4"

    18

    DO NOT GLUE JOINT

    USE REINFORCED TOP

    PVUP

    57-1

    819-

    L

    WOR

    K OR

    DER

    #

    APPR

    OVED

    BY:

    MAS

    TER:

    1391

    37

    3055

    73

    Universal Biotube® Pump Vaults (continued)Technical Data Sheet

    © 2012 Orenco Systems® Inc. NTD-PVU-LACEY-2Rev. 1.0, © 01/12

    Page 2 of 2

    SpecificationsModel PVU84-3625-LVault height (F) 84 in. Lowest float setting point (G) 38 in. Inlet hole height (H)* 25 in. Biotube® cartridge height (J) 36 in. Biotube mesh opening 0.125 in.Filter flow area 8.8 ft2 Filter surface area 29.0 ft2 Maximum flow rate 140 gpm

    * May vary depending on the configuration of the tank.

    Side view cutaway

    C

    D

    Top view

    Support pipes

    H

    F

    2" min.

    J

    G

    A

    B

    DimensionsA 3.0 in.B 4.0 in.C 17.3 in.D 16.6 in.E 12.0 in.

    Drain valve ball

    E

    eandrewsText BoxJ-51

  • Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-MF-MF-LACEY-2Rev. 2.0, © 01/18

    Page 1 of 2

    Float Sw