Aquamax TAN Titrator Application: The Aquamax TAN total acid number titrator has been designed to offer maximum specifications and features whilst being priced at a very competitive level. This titrator conforms to ASTM D664 for determination of acidic constituents in petroleum products, lubricants and transformer insulating oils.

Aquamax TAN Total Acid Number Titrator

Embed Size (px)

DESCRIPTION

Aquamax TAN total acid number titrator conforms to ASTM D664 for determination of acidic constituents in petroleum products, lubricants and transformer insulating oils

Citation preview

Page 1: Aquamax TAN Total Acid Number Titrator

AquamaxTAN Titrator

Application:

The Aquamax TAN total acid number titrator hasbeen designed to offer maximum specifications andfeatures whilst being priced at a very competitivelevel. This titrator conforms to ASTM D664 fordetermination of acidic constituents in petroleumproducts, lubricants and transformer insulating oils.

Page 2: Aquamax TAN Total Acid Number Titrator

tel: +44 1525 404747 fax: +44 1525 404848 [email protected] www.grscientific.com

Printer (optional)TiCom Software (optional)

Communications software between Aquamax TAN titrator and PC

Allows viewing and printing of all sample input, blank value and titrationmeasurement data. Reports on multiple samples can be generated directlyand exported to Excel or Access. Following data will be printed (or sent to PC) after

a titration:Header, instrument serial number, date and time, sampleID code, sample weight, titrant volume, titration result inmg KOH/g, titration duration, user name.

Aquamax TAN Titrator

Features and Benefits• Conforms to ASTM D664• Very easy to use - intuitive keypad and function guide display• Programmable – 3 easy to use programs depending on TAN content• Results expressed in mg KOH/g• 10ml high precision syringe – syringe volume dispensed in 40,000 steps.• Connects to external pc keyboard for easy text and sample information data entry• Connects to different types printers, pc and balances• Data Logger – automatic data storage of last 55 analysis results• Aquamax TAN applies differential measurement. Uses reference electrode with sleeve diaphragm

refilled with LiCl 1 mol/L in ethanol and glass+Pt indicator electrode.• Specially formulated and packaged reagent kits available. TAN solvents premixed in 100ml bottles

for easy use even by non laboratory personnel. Batch number traceability.• 2 RS 232C: for printer or PC and other for connection to balance

Page 3: Aquamax TAN Total Acid Number Titrator

tel: +44 1525 404747 fax: +44 1525 404848 [email protected] www.grscientific.com

How does it workAquamax TAN titrator conforms to ASTM D664

Usual procedure is

Calibration of the electrodes with aqueouspH11 buffer. Automatic rejection if electrodes inpoor condition.

Blank determination for the titration solvent. TheAquamax TAN determines the blank value andautomatically stores it in all titration programs.

TAN analysis. Select the suitable titration programin accordance with the expected TAN value andperform the titration.

Results are expressed in mg KOH/g. They arestored in the data logger, displayed on theAquamax TAN screen, and also sent to aprinter or PC.

Keypad

Easy to use - intuitivekeypad and functionguide display

Syringe

10ml high precision syringe – syringevolume dispensed in 40,000 steps.

Electrovalve

Fitted to top of syringeand controls flowdirection of reagent.

Electrodes

Uses reference electrode withsleeve diaphragm refilled withLiCl 1 mol/L in ethanol andglass+Pt indicator electrode.

Page 4: Aquamax TAN Total Acid Number Titrator

Technical SpecificationsNon-volatile memory: 3 titration programs depending on TAN content,

Blank titration, Clock/calendar.Header texts:2 lines x 40 characters. Name ofup to 4 operatorsUp to 50 results stored in Data Logger

Languages: English, Spanish, French, ItalianDisplay: Graphic backlit LCD, 128 x 64 dotsKeypad: Membrane, 7 keys, guaranteed up to 6 million

strokes per keyMaterial: PET with protective treatment

Syringe volume: Standard syringe 10 mlResolution: 1/40000 of syringe volumeDispensing accuracy; (as relative error) ≤ 0.2 % for volumes higher than

10 % of syringeDispensing ± 0.1 % for volumes higher than 10 % ofreproducibility: the syringeLiquid contact Syringe: borosilicate glass and PTFEmaterials : Electrovalve: PTFE and KEL-F. Tubes: PTFEInputs and outputs: Differential measurement: 2 BNC connectors.

For external keyboard, miniDIN connector.RS232C bidirectional for PC or printer,telephone connector.RS232C for balance, telephone connectorStirrer control: On/Off and speed, RCA connector

Power supply: 90 – 264 V AC, 47-63 HzElectrical safety: Meets EC, EN 61010EMC: Meets EC, EN 50081-2 and EN 50082-2Permitted temperatures: Operating: 10 – 40 ºC. Storage: 10 – 50 ºC

≤ 80 %, relative humidity, non condensingEnclosure: ABS and enamelled steelPhysical parameters: Weight: 4 kg approx.

Dimensions: 130 x 160 x 300mm

Ordering Information

About G.R. Scientific

The key personnel at G.R. Scientific are recognised experts in titrationinstrumentation, especially coulometric Karl Fischer, volumetric KarlFischer and Total Acid Number. They have designed and manufacturedtitrators since the early 1980’sand are widely recognised as someof the leading specialists in these techniques. G.R. Scientific alsomanufacture titrators for several OEM (private label) customers.

G.R. Scientific Limited, P.O. Box 242, AmpthillBedfordshire, MK45 5AQ United Kingdom

tel: +44 1525 404747 fax: +44 1525 404848 [email protected] www.grscientific.com

The Company reserves the right to change the specification or designwithout prior notice. Aquamax KF is a registered trade mark ofG.R. Scientific Ltd.

Part No. Product92000 Aquamax TAN titratorSupplied Accessories (also available as spare items)92-8736 1 x Power supply 90-264 VAC, 47-63 Hz92-9229 1 x TLL SL syringe, 10ml.92-8705 1 x Burette inlet tube with bottle cap, DIN 45 screw92-9199 1 x Filter cartridge with cotton92-8738 1 x Burette outlet tube with antidiffuser device92-9322 1 x Support with magnetic stirrer92-8760 2 x NS14/23 conical adapter92-8737 2 x Cap for support holes92-9323 1 x Pack of 3 titration vessel92-5251 1 x Indicator electrode (pH + Pt), with S7 connector92-5241 1 x Reference electrode, salt bridge, sleeve diaphragm,

with S7 connector92-9055 2 x Electrode cable with BNC connector92-9324 1 x Small vessel to calibrate, 50ml92-9520 1 x LiCl 1 M in Ethanol, 250ml bottle92-8734 Pack (10) white “O” rings

Part No. Product92-8201 Thermal printer CT-S280, 40 columns92-8200 Dot matrix printer92-9013 Standard PC keyboard92-8682 TiCom software kit for communication between Aquamax

TAN and PCIncludes CD with software and cable

Optional Accessories

For additionaltechnical information,specifications, MSDS data, user manuals,and exhibition news, visit our website at:

www.grscientific.com

CertificatesAll Aquamax TAN titrators are supplied with:• EC Declaration of conformity according to directiveC.E.M. 89/336/CE

• Calibration test of dispensed volume with the syringe• Specifications certificate and mV measuring test.