SECTION 08 51 13 ALUMINUM WINDOWS 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Fixed Window Units - ENERGSAVE Architectural: 1.1.1.1 Peerless G741 Fixed Thermal Aluminum Windows. 1.1.1.2 Peerless G641 Fixed Thermal Aluminum Windows. 1.1.1.3 Peerless G541 Fixed Thermal Aluminum Windows. 1.1.1.4 Peerless G441 Fixed Thermal Aluminum Windows. 1.1.1.5 Peerless G341 Fixed Thermal Aluminum Windows. 1.1.1.6 Peerless G241 Fixed Thermal Aluminum Windows. 1.1.1.7 Peerless G141 Fixed Thermal Aluminum Windows. 1.1.2 Fixed Window Units - Architectural: 1.1.2.1 Peerless Series 4170-R Fixed Thermal Aluminum Windows. 1.1.2.2 Peerless Series 4160-R Fixed Thermal Aluminum Windows. 1.1.3 Hung Window Units - ENERGSAVE Architectural: 1.1.3.1 Peerless GSH6 Single Hung Tilt Thermal Aluminum Windows. 1.1.3.2 Peerless GSH5 Single Hung Tilt Thermal Aluminum Windows. 1.1.3.3 Peerless GSH3 Single Hung Tilt Thermal Aluminum Windows. 1.1.3.4 Peerless GDH5 Double Hung Tilt Thermal Aluminum Windows. 1.1.3.5 Peerless GDH3 Double Hung Tilt Thermal Aluminum Windows. 1.1.4 Hung Window Units - Architectural: 1.1.4.1 Peerless Series 9150-R Single Hung, Side Load Thermal Aluminum Windows. 1.1.4.2 Peerless Series 4130-R Single Hung, Tilt Sash Thermal Aluminum Windows. 1.1.5 Projected Window Units - ENERGSAVE Architectural: 1.1.5.1 Peerless G701 Project-Out Thermal Aluminum Windows. 1.1.5.2 Peerless G601 Project-Out Thermal Aluminum Windows. 1.1.5.3 Peerless G501 Project-Out Thermal Aluminum Windows. 1.1.5.4 Peerless G401 Project-Out Thermal Aluminum Windows. 1.1.5.5 Peerless G301 Project-Out Thermal Aluminum Windows. 1.1.5.6 Peerless G201 Project-Out Thermal Aluminum Windows. 1.1.5.7 Peerless G101 Project-Out Thermal Aluminum Windows. 1.1.5.8 Peerless G711 Project-In Thermal Aluminum Windows. 1.1.5.9 Peerless G611 Project-In Thermal Aluminum Windows. 1.1.5.10 Peerless G511 Project-In Thermal Aluminum Windows. 1.1.5.11 Peerless G411 Project-In Thermal Aluminum Windows. 08 51 13-1

ARCAT | Free Building Product CAD Details, BIM, Specs ... · Web viewAAMA - American Architectural Manufacturers Association: AAMA/ WDMA/CSA 101/I.S.2/ A440-08 "Standard/Specification

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

SECTION 08 51 13

ALUMINUM WINDOWS

** NOTE TO SPECIFIER ** Peerless Products, Inc.; aluminum windows..This section is based on the products of Peerless Products, Inc., which is located at:2403 S. Main St.Ft. Scott, KS 66701Toll Free Tel: 866-420-4000Tel: 620-223-4610Fax: 620-224-3107Email: request info ([email protected])Web: www.peerlessproducts.com [ Click Here ] for additional information.Our ENERGSAVE windows are some of the most energy efficient in the industry. We also offer blast resistant and hurricane certified windows and doors as well as acoustical products. If you need to preserve the architectural beauty of a historical building we can help you there too.

1 GENERAL

1.1 SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for project.

1.1.1 Fixed Window Units - ENERGSAVE Architectural:

1.1.1.1 Peerless G741 Fixed Thermal Aluminum Windows.

1.1.1.2 Peerless G641 Fixed Thermal Aluminum Windows.

1.1.1.3 Peerless G541 Fixed Thermal Aluminum Windows.

1.1.1.4 Peerless G441 Fixed Thermal Aluminum Windows.

1.1.1.5 Peerless G341 Fixed Thermal Aluminum Windows.

1.1.1.6 Peerless G241 Fixed Thermal Aluminum Windows.

1.1.1.7 Peerless G141 Fixed Thermal Aluminum Windows.

1.1.2 Fixed Window Units - Architectural:

1.1.2.1 Peerless Series 4170-R Fixed Thermal Aluminum Windows.

1.1.2.2 Peerless Series 4160-R Fixed Thermal Aluminum Windows.

1.1.3 Hung Window Units - ENERGSAVE Architectural:

1.1.3.1 Peerless GSH6 Single Hung Tilt Thermal Aluminum Windows.

1.1.3.2 Peerless GSH5 Single Hung Tilt Thermal Aluminum Windows.

1.1.3.3 Peerless GSH3 Single Hung Tilt Thermal Aluminum Windows.

1.1.3.4 Peerless GDH5 Double Hung Tilt Thermal Aluminum Windows.

1.1.3.5 Peerless GDH3 Double Hung Tilt Thermal Aluminum Windows.

1.1.4 Hung Window Units - Architectural:

1.1.4.1 Peerless Series 9150-R Single Hung, Side Load Thermal Aluminum Windows.

1.1.4.2 Peerless Series 4130-R Single Hung, Tilt Sash Thermal Aluminum Windows.

1.1.5 Projected Window Units - ENERGSAVE Architectural:

1.1.5.1 Peerless G701 Project-Out Thermal Aluminum Windows.

1.1.5.2 Peerless G601 Project-Out Thermal Aluminum Windows.

1.1.5.3 Peerless G501 Project-Out Thermal Aluminum Windows.

1.1.5.4 Peerless G401 Project-Out Thermal Aluminum Windows.

1.1.5.5 Peerless G301 Project-Out Thermal Aluminum Windows.

1.1.5.6 Peerless G201 Project-Out Thermal Aluminum Windows.

1.1.5.7 Peerless G101 Project-Out Thermal Aluminum Windows.

1.1.5.8 Peerless G711 Project-In Thermal Aluminum Windows.

1.1.5.9 Peerless G611 Project-In Thermal Aluminum Windows.

1.1.5.10 Peerless G511 Project-In Thermal Aluminum Windows.

1.1.5.11 Peerless G411 Project-In Thermal Aluminum Windows.

1.1.5.12 Peerless G311 Project-In Thermal Aluminum Windows.

1.1.5.13 Peerless G211 Project-In Thermal Aluminum Windows.

1.1.5.14 Peerless G111 Project-In Thermal Aluminum Windows.

1.1.6 Casement Window Units - ENERGSAVE Architectural:

1.1.6.1 Peerless G751 Left Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.2 Peerless G755 Right Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.3 Peerless G651 Left Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.4 Peerless G655 Right Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.5 Peerless G551 Left Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.6 Peerless G555 Right Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.7 Peerless G451 Left Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.8 Peerless G455 Right Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.9 Peerless G351 Left Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.10 Peerless G355 Right Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.11 Peerless G251 Left Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.12 Peerless G255 Right Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.13 Peerless G151 Left Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.14 Peerless G155 Right Hand Casement Outswing Thermal Aluminum Windows.

1.1.6.15 Peerless G761 Left Hand Casement Inswing Thermal Aluminum Windows.

1.1.6.16 Peerless G765 Right Hand Casement Inswing Thermal Aluminum Windows.

1.1.6.17 Peerless G661 Left Hand Casement Inswing Thermal Aluminum Windows.

1.1.6.18 Peerless G665 Right Hand Casement Inswing Thermal Aluminum Windows.

1.1.6.19 Peerless G561 Left Hand Casement Inswing Thermal Aluminum Windows.

1.1.6.20 Peerless G565 Right Hand Casement Inswing Thermal Aluminum Windows.

1.1.6.21 Peerless G461 Left Hand Casement Inswing Thermal Aluminum Windows.

1.1.6.22 Peerless G465 Right Hand Casement Inswing Thermal Aluminum Windows.

1.1.6.23 Peerless G361 Left Hand Casement Inswing Thermal Aluminum Windows.

1.1.6.24 Peerless G365 Right Hand Casement Inswing Thermal Aluminum Windows.

1.1.6.25 Peerless G261 Left Hand Casement Inswing Thermal Aluminum Windows.

1.1.6.26 Peerless G265 Right Hand Casement Inswing Thermal Aluminum Windows.

1.1.6.27 Peerless G161 Left Hand Casement Inswing Thermal Aluminum Windows.

1.1.6.28 Peerless G165 Right Hand Casement Inswing Thermal Aluminum Windows.

1.1.7 Dual Action Window Units ENERGSAVE Architectural:

1.1.7.1 Peerless G5T1 Left Hand Dual Action Vent Casement Inswing Thermal Aluminum Windows.

1.1.7.2 Peerless G5T5 Right Hand Dual Action Vent Casement Inswing Thermal Aluminum Windows.

1.1.7.3 Peerless G4T1 Left Hand Dual Action Vent Casement Inswing Thermal Aluminum Windows.

1.1.7.4 Peerless G4T5 Right Hand Dual Action Vent Casement Inswing Thermal Aluminum Windows.

1.1.7.5 Peerless G3T1 Left Hand Dual Action Vent Casement Inswing Thermal Aluminum Windows.

1.1.7.6 Peerless G3T5 Right Hand Dual Action Vent Casement Inswing Thermal Aluminum Windows.

1.1.7.7 Peerless G2T1 Left Hand Dual Action Vent Casement Inswing Thermal Aluminum Windows.

1.1.7.8 Peerless G2T5 Right Hand Dual Action Vent Casement Inswing Thermal Aluminum Windows.

1.1.7.9 Peerless G1T1 Left Hand Dual Action Vent Casement Inswing Thermal Aluminum Windows.

1.1.7.10 Peerless G1T5 Right Hand Dual Action Vent Casement Inswing Thermal Aluminum Windows.

1.1.8 Horizontal Slider Window Units - ENERGSAVE Architectural.

1.1.8.1 Peerless GSL2 Horizontal Sliding Thermal Aluminum Windows.

1.1.9 Horizontal Slider Window Units - Architectural.

1.1.9.1 Peerless Series 9530-R Horizontal Sliding Thermal Aluminum Windows.

1.1.10 Sliding Glass Doors ENERGSAVE Architectural.

1.1.10.1 Peerless GSD2 Thermal Aluminum Sliding Glass Doors.

1.1.11 Terrace Doors ENERGSAVE Architectural.

1.1.11.1 Peerless GTD2 Thermal Aluminum Terrace Doors.

1.1.11.2 Peerless GTD3 Thermal Aluminum Terrace Doors.

1.1.11.3 Peerless GTD5 Thermal Aluminum Terrace Doors.

1.1.12 Psychiatric Rated Fixed Window Units - ENERGSAVE Architectural.

1.1.12.1 Peerless P541 Fixed Thermal Aluminum Psychiatric Windows.

1.2 RELATED SECTIONS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

1.2.1 Section 07 91 26 - Joint Fillers0 - Joint Fillers - Joint Sealants.

1.3 REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

1.3.1 AAMA - American Architectural Manufacturers Association:

1.3.1.1 AAMA/ WDMA/CSA 101/I.S.2/ A440-08 "Standard/Specification for windows, doors, and unit skylights".

1.3.1.2 AAMA 502-12 "Voluntary Specification for Field Testing of Newly Installed Fenestration Products".

1.3.1.3 AAMA 611-12 "Voluntary Specification for Anodized Architectural Aluminum".

1.3.1.4 AAMA 701/702-11 "Voluntary Specification for Pile Weatherstripping and Replaceable Fenestration Weatherseals".

1.3.1.5 AAMA 901-10 "Voluntary Specification for Rotary & Linear Operators in Window Applications".

1.3.1.6 AAMA 902-07 "Voluntary Specification for Sash Balances".

1.3.1.7 AAMA 904-09 "Voluntary Specification for Multi-bar Hinges in Window Applications".

1.3.1.8 AAMA 910-10 "Voluntary ' Life Cycle' Specifications and Test Methods for AW Class Architectural Windows and Doors".

1.3.1.9 AAMA 920-11 "Specification for Operating Cycle Performance of Side-Hinged Exterior Door Systems".

1.3.1.10 AAMA 1304-02 "Voluntary Specification for Forced Entry Resistance of Side-Hinged Door Systems".

1.3.1.11 AAMA 1503-09 "Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors, and Glazed Wall Sections".

1.3.1.12 AAMA 2605-13 "Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels"

1.3.1.13 AAMA CW-10-12 "Care and Handling of Architectural Aluminum from Shop to Site"

1.3.1.14 AAMA 501.8-12 "Standard Test Method for Determination of Resistance to Human Impact of Window Systems Intended for Use in Psychiatric Applications".

1.3.2 ASTM International:

1.3.2.1 ASTM E90-09 "Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements".

1.3.2.2 ASTM E283-12 "Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen".

1.3.2.3 ASTM E330-14 "Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Uniform Static Air Pressure Difference".

1.3.2.4 ASTM E331-09 "Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference".

1.3.2.5 ASTM E547-09 "Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Differential".

1.3.2.6 ASTM E2190-10 "Standard Specification for Insulating Glass Unit Performance and Evaluation".

1.3.2.7 ASTM F588-07 "Standard Test Methods for Measuring the Forced Entry Resistance of Window Assemblies, Excluding Glazing Impact".

1.3.3 IGCC - Insulating Glass Certification Council.

1.3.4 NFRC - National Fenestration Rating Council:

1.3.4.1 NFRC 100-2010 "Procedure for Determining Fenestration Product U Factors".

1.3.4.2 NFRC 102-2010 "Procedure for Measuring the Steady-State Thermal Transmittance of Fenestration Systems".

1.3.5 SGCC - Safety Glazing Certification Council:

1.3.5.1 ANSI Z97.1-09 "American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test".

1.3.5.2 16 CFR 1201 "Consumer Product Safety Commission Safety Standard for Architectural Glazing Materials - codified at Title 16, Part 1201 of the Code of Federal Regulations 2011 Edition".

1.4 SUBMITTALS

1.4.1 Product Data: Manufacturer's data sheets on each product to be used, including:

1.4.1.1 Manufacturer's specifications and test reports or waiver from an AAMA-accredited laboratory.

1.4.2 Shop Drawings: Window location chart; typical window elevations; details of assemblies, hardware and glazing details for units glazed by the window manufacturer.

** NOTE TO SPECIFIER ** Delete selection samples if colors have already been selected.

1.4.3 Samples: each specified finish for aluminum; other samples as requested.

1.5 QUALITY ASSURANCE

1.5.1 Installer Qualifications: Skilled craftspeople who have demonstrated a successful history of installing windows for five years.

1.5.2 Product Requirements:

1.5.2.1 Furnish a valid AAMA "Authorization for Product Certification" or waiver indicating that the windows for the project conform to AAMA/WDMA/CSA 101/I.S.2/A440-08.

1.5.2.2 Furnish certification indicating AAMA Certification: Conformance with ASTM E 2190 on the insulating glass units.

1.5.2.3 Furnish visible, permanent SGCC certification labels indicating AAMA Certification: Conformance with ANSI Z97.1-09 and/or 16 CFR 1201 on tempered glass lites, if included on the project, and laminated glass lites, if included on the project.

** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.

1.5.3 Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.

1.5.3.1 Finish areas designated by Architect.

1.5.3.2 Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.

1.5.3.3 Refinish mock-up area as required to produce acceptable work.

1.6 DELIVERY, STORAGE, AND HANDLING

1.6.1 Store products in manufacturer's unopened packaging until ready for installation.

1.6.2 Handle and protect windows and accessories in accordance with AAMA CW-10-12 until project completion.

1.7 PROJECT CONDITIONS

1.7.1 Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

1.8 WARRANTY

1.8.1 Manufacturer's Warranties:

1.8.1.1 Windows: Manufacturer shall warrant for one year against defects in material and workmanship under normal use.

1.8.1.2 Insulating Glass Units: Glass manufacturer shall warrant seal for ten years against visual obstruction from film formation or moisture collection between internal glass surfaces, excluding that caused by glass breakage or abuse.

1.8.1.3 Paint Finish: Organic finish conforming to AAMA 2605 shall be warranted for twenty years against chipping, peeling, blistering, cracking, chalking, or fading.

2 PRODUCTS

2.1 MANUFACTURERS

2.1.1 Acceptable Manufacturer: Peerless Products, Inc., which is located at: 2403 S. Main St.; Ft. Scott, KS 66701; Toll Free Tel: 866-420-4000; Tel: 620-223-4610; Fax: 620-224-3107; Email: request info ([email protected]); Web: www.peerlessproducts.com

2.1.2 Web: http://www.peerlessproducts.com.

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

2.1.3 Substitutions: Not permitted.

2.1.4 Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.

** NOTE TO SPECIFIER ** Delete if not required.

2.2 FIXED WINDOW UNITS - ENERGSAVE ARCHITECTURAL

** NOTE TO SPECIFIER ** ENERGSAVE G-Series. Delete window not required.

2.2.1 Product: Peerless G741 Fixed Thermal Aluminum Window.

2.2.1.1 AAMA Certification: Conformance with FW-AW70.

2.2.2 Product: Peerless G641 Fixed Thermal Aluminum Window.

2.2.2.1 AAMA Certification: Conformance with FW-AW70.

2.2.3 Product: Peerless G541 Fixed Thermal Aluminum Window.

2.2.3.1 AAMA Certification: Conformance with FW-AW70.

2.2.4 Product: Peerless G441 Fixed Thermal Aluminum Window.

2.2.4.1 AAMA Certification: Conformance with FW-AW70.

2.2.5 Product: Peerless G341 Fixed Thermal Aluminum Window.

2.2.5.1 AAMA Certification: Conformance with FW-AW70.

2.2.6 Product: Peerless G241 Fixed Thermal Aluminum Window:

2.2.6.1 AAMA Certification: Conformance with FW-AW70.

2.2.7 Product: Peerless G141 Fixed Thermal Aluminum Window:

2.2.7.1 AAMA Certification: Conformance with FW-AW70.

** NOTE TO SPECIFIER ** All G-Series windows. Delete configuration not required.

2.2.8 Configuration:

2.2.8.1 Fixed; glass plane in line with the window exterior plane.

2.2.8.2 Fixed-to-fixed with a vertical integral mullion in one master frame; glass plane in line with the window exterior plane.

2.2.8.3 Fixed-under-fixed with a horizontal integral mullion in one master frame; glass plane in line with the window exterior plane.

2.2.8.4 Fixed-over-fixed with a horizontal integral mullion in one master frame; glass plane in line with the window exterior plane.

** NOTE TO SPECIFIER ** Construction for ENERGSAVE series windows.

2.2.9 Construction:

2.2.9.1 Aluminum Extrusions: extruded by the window manufacturer from commercial quality 6063-T5 alloy; free from defects impairing strength and durability.

2.2.9.2 Window Frame: Extruded aluminum with integral structural thermal break installed by the window manufacturer in the frame members; exterior and interior finishes applied by the window manufacturer; frames assembled by the window manufacturer.

** NOTE TO SPECIFIER ** Peerless G741. Delete if not required.

2.2.9.2.1 Frame Depth: 2 inches (51 mm).

** NOTE TO SPECIFIER ** Peerless G141. Delete if not required.

2.2.9.2.2 Frame Depth: 2-1/2 inches (64 mm).

** NOTE TO SPECIFIER ** Peerless G241, Peerless G341, Peerless G441, and Peerless G641. Delete if not required.

2.2.9.2.3 Frame Depth: 3-1/4 inches (83 mm).

** NOTE TO SPECIFIER ** Peerless G541. Delete if not required.

2.2.9.2.4 Frame Depth: 4-1/4 inches (108 mm).

** NOTE TO SPECIFIER ** Delete construction not required.

2.2.9.2.5 Fabricated with equal-leg flange frame.

2.2.9.2.6 Fabricated with equal-leg prime/nailing fin frame.

** NOTE TO SPECIFIER ** Peerless G141 Fixed, Peerless G241 Fixed, Peerless G341 Fixed, Peerless G441 Fixed, Peerless G541 Fixed, and Peerless G641 Fixed. Delete if not required.

2.2.9.3 Frame: Double tubular head, sill, and jambs miter cut and fastened with two zamac corner gussets per corner; corners sealed by window manufacturer with sealant conforming to AAMA 800-10.

** NOTE TO SPECIFIER ** Peerless G141 Fixed, Peerless G241 Fixed, Peerless G341 Fixed, Peerless G441 Fixed, Peerless G541 Fixed, and Peerless G641 Fixed. Delete if not required.

2.2.9.4 Integral Mullions: Double tubular integral mullion fastened with two Zamac gussets per frame member without penetrating the frame member with fasteners; joints sealed by window manufacturer with sealant conforming to AAMA 800-10.

** NOTE TO SPECIFIER ** Peerless G741 Fixed. Delete if not required.

2.2.9.5 Frame: Single tubular head, sill, and jambs miter cut and fastened with one Zamac corner gussets per corner; corners sealed by window manufacturer with sealant conforming to AAMA 800-10.

** NOTE TO SPECIFIER ** Peerless G741 Fixed. Delete if not required.

2.2.9.6 Integral Mullions: Single tubular integral mullion fastened with one Zamac gusset per frame member without penetrating the frame member with fasteners; joints sealed by window manufacturer with sealant conforming to AAMA 800-10.

** NOTE TO SPECIFIER ** Peerless G441 Fixed. Delete if not required.

2.2.9.7 Interior take-out panel: horizontal bottom lift rail, top rail, and both vertical stiles miter cut and fastened with one stainless steel screw per corner for easy reglazing; unauthorized removal of the panel restricted with two tamperproof screws.

2.2.9.8 Thermal Break: The thermal break separating the exterior and interior aluminum extrusions shall be a mechanical crimp-in-place system utilizing multi-directional glass fiber reinforced polyamide nylon ribbed struts with locking mechanical connections to the aluminum extrusions. The thermal break shall not be compromised by hardware or metal fasteners.

2.2.9.9 Glazing: exterior ExxonMobil Santoprene foam gasket, 1 inch (25 mm) insulating glass, two weep holes under each glass pocket for drainage with hooded weeps and paint to match cover, foam backer rod and silicone heel bead forming an internal seal, interior Santoprene bulb gasket threaded into aluminum glazing beads, 1/4 inch (6 mm) glass; glazed by the window manufacturer.

2.2.9.10 Weatherstrip: secured in extruded ports; Santoprene bulb seal conforming to AAMA 702-11 in interior aluminum glazing beads; Teflon-coated bulb with a foam core conforming to AAMA 702-11: single row on the exterior of the stiles and rails of the interior take-out panel.

** NOTE TO SPECIFIER ** Performance for ENERGSAVE windows.

2.2.10 Performance:

2.2.10.1 AAMA Certification: Conformance to AW-PG70-FW specifications in AAMA/WDMA/CSA 101/I.S.2/A440-08 when tests are performed on the prescribed 60 inches by 99 inches (1524 mm by 2515 mm) minimum test size with the following test results:

** NOTE TO SPECIFIER typical for all models except those listed below. Delete if not required.

2.2.10.2 Air Infiltration: Not to exceed AAMA 101 standard of maximum 0.1 cfm/square foot when tested per ASTM E283-12 at a static air pressure difference of 6.24 psf.

** NOTE TO SPECIFIER ** Peerless G141, Peerless G241, Peerless G341, Peerless G441, Peerless G541, Peerless G641, and Peerless G741 Fixed. Delete if not required.

2.2.10.3 Water Penetration: No uncontrolled water leakage when tested per ASTM E331-09 and ASTM E547-09 at a static air pressure difference of 15 psf.

2.2.10.4 Uniform Deflection: No more than L/175 when tested per ASTM E330-14 at a static air pressure difference of 70 psf.

** NOTE TO SPECIFIER ** Typical for all ENERGSAVE series.

2.2.10.5 Uniform Structural Load: No glass breakage or permanent damage to fasteners, and maximum .2% permanent deformation of the span of any frame member when tested per ASTM E330-14 at a static air pressure difference of 105 psf.

** NOTE TO SPECIFIER ** Typical for all ENERGSAVE series. Delete if not required.

2.2.10.6 Forced-entry Resistance: Reasonable security against forced entry and the test window shall achieve a Grade 40 when tested per ASTM F588-07.

** NOTE TO SPECIFIER ** ENERGSAVE G-Series only. Delete if not required.

2.2.11 Thermal NFRC Simulation: Thermal computer simulation per NFRC 100-2010 on a 60 inches by 99 inches (1524 mm by 2515 mm) test size glazed with 1 inch (25 mm) insulating made with 1/4 inch (6 mm) soft coat low E coating on surface #2, argon gas in the airspace made with a stainless steel spacer, and 1/4 inch (6 mm) clear glass, with the following test result:

** NOTE TO SPECIFIER ** Peerless G141 Fixed. Delete if not required.

2.2.11.1 Standardized Thermal Transmittance to be maximum 0.314 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G241 Fixed. Delete if not required.

2.2.11.2 Standardized Thermal Transmittance to be maximum 0.309 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G341 Fixed. Delete if not required.

2.2.11.3 Standardized Thermal Transmittance to be maximum 0.300 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G441 Fixed. Delete if not required.

2.2.11.4 Standardized Thermal Transmittance to be maximum 0.236 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G641 Fixed. Delete if not required.

2.2.11.5 Standardized Thermal Transmittance to be maximum 0.304 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G741 Fixed. Delete if not required.

2.2.11.6 Standardized Thermal Transmittance to be maximum 0.293 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G541 Fixed. Delete if not required.

2.2.12 Thermal NFRC Simulation: thermal computer simulation per NFRC 100-2010 on a 60 inches by 99 inches (1524 mm by 2515 mm) test size glazed with 1-3/4 Inches (44.5 mm) triple insulating glass made with exterior 1/4 inch (6 mm) glass with a soft coat low E coating on surface #2, argon gas in the airspace made with a stainless steel spacer, internal 1/4 inch (6 mm) clear glass, argon in the airspace made with a stainless steel spacer, and interior 1/4 inch (6 mm) glass with a soft coat low E coating on surface #5, with the following test result: Standardized Thermal Transmittance to be maximum 0.150 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER **Typical for all ENERGSAVE series. Delete if not required.

2.2.13 Thermal AAMA Testing: Per AAMA 1503-09, on a 47 inch by 59 inches (1194 mm by 1499 mm) test size glazed with 1 inch (25 mm) insulating glass made with 1/4 inch (6 mm) soft coat low E coating on surface #2, plain air in the airspace made with a stainless steel spacer, and 1/4 inch (6 mm) clear glass, with the following test results:

** NOTE TO SPECIFIER ** Peerless G141 Fixed. Delete if not required.

2.2.13.1 Condensation Resistance Factor: minimum 64 frame CRF and 73 glass CRF.

2.2.13.2 Thermal Transmittance: maximum 0.37 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G241 Fixed. Delete if not required.

2.2.13.3 Condensation Resistance Factor: minimum 71 frame CRF and 72 glass CRF.

2.2.13.4 Thermal Transmittance: maximum 0.35 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G341 Fixed. Delete if not required.

2.2.13.5 Condensation Resistance Factor: minimum 73 frame CRF and 71 glass CRF.

2.2.13.6 Thermal Transmittance: maximum 0.34 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G441 Fixed. Delete if not required.

2.2.13.7 Condensation Resistance Factor: minimum 73 frame CRF and 71 glass CRF.

2.2.13.8 Thermal Transmittance: maximum 0.278 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G541 Fixed. Delete if not required.

2.2.13.9 Condensation Resistance Factor: minimum 82 frame CRF and 85 glass CRF.

2.2.13.10 Thermal Transmittance: maximum 0.16 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G641 Fixed. Delete if not required.

2.2.13.11 Condensation Resistance Factor: minimum 67 frame CRF and 73 glass CRF.

2.2.13.12 Thermal Transmittance: maximum 0.35 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G741 Fixed. Delete if not required.

2.2.13.13 Condensation Resistance Factor: minimum 63 frame CRF and 71 glass CRF.

2.2.13.14 Thermal Transmittance: maximum 0.31 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** ENERGSAVE G-Series only. Delete if not required.

2.2.14 Thermal NFRC Testing: Per NFRC 102-2010 on a 47 inch by 59 inches (1194 mm by 1499 mm) test size glazed with 1 inch (25 mm) insulating glass made with 1/4 inch (6 mm) soft coat low E coating on surface #2, plain air in the airspace made with a stainless steel spacer, and 1/4 inch (6 mm) clear glass, with the following test result:

** NOTE TO SPECIFIER ** Peerless G141 Fixed. Delete if not required.

2.2.14.1 Standardized Thermal Transmittance to be maximum 0.36 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G241 Fixed. Delete if not required.

2.2.14.2 Standardized Thermal Transmittance to be maximum 0.34 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G341 Fixed. Delete if not required.

2.2.14.3 Standardized Thermal Transmittance to be maximum 0.33 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G441 Fixed. Delete if not required.

2.2.14.4 Standardized Thermal Transmittance to be maximum 0.33 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G541 Fixed. Delete if not required.

2.2.14.5 Standardized Thermal Transmittance to be maximum 0.16 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G641 Fixed. Delete if not required.

2.2.14.6 Standardized Thermal Transmittance to be maximum 0.34 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G741 Fixed. Delete if not required.

2.2.14.7 Standardized Thermal Transmittance to be maximum 0.30 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G241 Fixed. Delete if not required.

2.2.15 Acoustical Testing: per ASTM E90-09 on a 46-1/4 inches x 59 inches (1175 mm x 1499 mm) test size glazed with 1-3/8 inches (35 mm) insulating glass made with exterior 5/16 (7.9 mm) laminated glass - 1/8 inch (3 mm) glass x .060 inch (1.5 mm) PVB interlayer x 1/8 inch (3 mm) glass - and 13/16 inch (20.6 mm) airspace and interior 1/4 inch (6 mm) laminated glass - 1/8 inch (3 mm) glass x .030 inch (0.76 mm) PVB interlayer x 1/8 inch (3 mm) glass: minimum 40 STC and 31 OITC.

** NOTE TO SPECIFIER ** Peerless G341 Fixed. Delete if not required.

2.2.16 Acoustical Performance: Testing per ASTM E90-09 on a 46-1/4 inches by 59 inches (1175 mm by 1499 mm) test size glazed with 1 inch (25 mm) insulating glass made with exterior 1/4 inch (6 mm) monolithic glass, 9/16 inch (14 mm) airspace, and interior 1/4 inch (6 mm) monolithic glass: minimum 36 STC and 28 OITC.

** NOTE TO SPECIFIER ** Peerless G441 Fixed. Delete if not required.

2.2.17 Acoustical Performance: Testing per ASTM E90-09 on a 46-1/4 inches by 59 inches (1175 mm by 1499 mm) test size triple glazed with exterior 1-3/8 inches (35 mm) insulating glass made with exterior 7/16 inch (11 mm) laminated glass - 3/16 inch (4.8 mm) glass by .060 inch (1.5 mm) PVB interlayer by 3/16 inch (4.8 mm) glass - by 11/16 inch (17.5 mm) airspace by interior 1/4 inch (6 mm) laminated glass - 1/8 inch (3 mm) glass by .060 inch (1.5 mm) PVB interlayer by 1/8 inch (3 mm) glass -, and interior single glazed with 5/16 inch (7.9 mm) laminated glass - 1/8 inch (3 mm) glass by .030 inch (0.76 mm) PVB interlayer by 1/8 inch (3 mm) glass: Minimum 47 STC and 37 OITC.

** NOTE TO SPECIFIER ** Peerless G641 Fixed. Delete if not required.

2.2.18 Acoustical Performance: Testing per ASTM E90-09 on a 46-1/4 inches by 59 inches (1175 mm by 1499 mm) test size glazed with 1 1/4 inch (31.8 mm) dual glazed units which were made with exterior 1/4 inch (6 mm) monolithic glass, 3/4 inch (19.1 mm) airspace with a stainless steel spacer, and interior 1/4 inch (6 mm) laminated glass. The laminated glass utilized a .030 inch (.76 mm) interlayer: minimum 38 STC and 28 OITC.

** NOTE TO SPECIFIER ** Peerless G741 Fixed. Delete if not required.

2.2.19 Acoustical Performance: Testing per ASTM E90-09 on a 46-1/4 inches by 59 inches (1175 mm by 1499 mm) test size glazed with 1 inch (25 mm) dual glazed units which were made with exterior 1/4 inch (6 mm) monolithic glass, 7/16 inch (11 mm) airspace with a stainless steel spacer, and interior 5/16 inch (8 mm) monolithic glass: minimum 38 STC and 30 OITC.

** NOTE TO SPECIFIER ** Delete if not required.

2.3 FIXED WINDOW UNITS - ARCHITECTURAL

** NOTE TO SPECIFIER ** Architectural series windows. Delete window not required.

2.3.1 Product: Peerless Products, Inc. Series 4170-R Thermal Fixed window.

2.3.1.1 AAMA Certification: Conformance with FW-AW70.

2.3.1.2 Frame Depth: 4 inches (102 mm).

2.3.2 Product: Peerless Products, Inc. Series 4160-R Thermal Fixed window.

2.3.2.1 AAMA Certification: Conformance with FW-AW70.

2.3.2.2 Frame Depth: 3-1/4 inches (82 mm).

** NOTE TO SPECIFIER ** Construction for architectural series windows

2.3.3 Construction:

2.3.3.1 Material: Extruded aluminum shall be 0.062 inch (1.57 mm) 6063-T5 alloy and tempered.

2.3.3.2 Design: Extruded aluminum with integral structural thermal break in the frame and sash members.

2.3.3.3 Fasteners shall be aluminum, non-magnetic stainless steel or other materials warranted by the manufacturer to be non-corrosive and compatible with aluminum window members, trim, hardware, anchors and other components of the window units.

2.3.3.4 Thermal Break: The thermal break separating the exterior and interior aluminum extrusions shall be a mechanical crimp-in-place system utilizing multi-directional glass fiber reinforced polyamide nylon ribbed struts with locking mechanical connections to the aluminum extrusions. The thermal break shall not be compromised by hardware or metal fasteners.

2.3.3.5 Glazing: exterior ExxonMobil Santoprene foam gasket, 1 inch (25 mm) insulating glass, two weep holes under each glass pocket for drainage with hooded weeps and paint to match cover, foam backer rod and silicone heel bead forming an internal seal, interior Santoprene bulb gasket threaded into aluminum glazing beads, 1/4 inch (6 mm) glass; glazed by the window manufacturer.

2.3.3.6 Glazing beads shall be extruded aluminum and shall be of sufficient strength to retain the glass.

2.3.3.7 Fabrication:

2.3.3.7.1 Units shall be able to be re-glazed without dismantling the master or sash frame.

2.3.3.7.2 Aluminum frame and sash extrusions shall have a minimum wall thickness of 0.062 inch (1.57 mm). Mechanical fasteners, welded components and hardware items shall not bridge thermal barriers. Thermal barriers shall align at all frame and sash corners.

2.3.3.7.3 Frame components shall be mechanically fastened.

2.3.3.7.4 Sash frame vertical extrusions shall be of tubular design.

2.3.3.7.5 Sash corners shall be mechanically fastened.

** NOTE TO SPECIFIER ** Performance for architectural windows.

2.3.4 Performance:

2.3.4.1 AAMA Certification: Conformance with AAMA/WDMA/CSA 101/I.S.2/A440-08 when tests are performed on the prescribed 60 inches by 99 inches (1524 mm by 2515 mm) minimum test size with the following test results:

2.3.4.2 Air Infiltration: Not to exceed AAMA 101 standard of maximum 0.1 cfm/square foot when tested per ASTM E283-04 at a static air pressure difference of 6.24 psf.

** NOTE TO SPECIFIER ** Peerless 4160-R and Peerless 4170-R. Delete if not required.

2.3.4.3 Water Penetration: No uncontrolled water leakage when tested per ASTM E331-09 and ASTM E547-09 at a static air pressure difference of 15 psf.

2.3.4.4 Uniform Structural Load: No glass breakage or permanent damage to fasteners when tested per ASTM E330.

2.3.4.4.1 Static air pressure difference of 105 psf.

** NOTE TO SPECIFIER ** ENERGSAVE G-Series window units only. Delete if not required.

2.4 HUNG WINDOW UNITS - ENERGSAVE ARCHITECTURAL

** NOTE TO SPECIFIER ** Delete product not required.

2.4.1 Product: Peerless GSH6 Single Hung Tilt Thermal Aluminum Window:

2.4.1.1 AAMA Certification: Conformance with AW-PG50-H.

** NOTE TO SPECIFIER ** Delete configuration not required.

2.4.1.2 Configuration: Single hung bottom sash tilts in for glass cleaning.

2.4.1.3 Configuration: Single hung-to-single hung with continuous head and sill in one master frame; bottom sash tilts in for glass cleaning.

2.4.1.4 Configuration: Single hung-to-side fixed with continuous head and sill in one master frame; bottom sash tilts in for glass cleaning.

2.4.1.5 Configuration: Single hung-under-fixed with continuous jambs in one master frame; bottom sash tilts in for glass cleaning.

2.4.1.6 Configuration: Single hung-over-fixed with continuous jambs in one master frame; bottom sash tilts in for glass cleaning.

2.4.2 Product: Peerless GSH5 Single Hung Tilt Thermal Aluminum Window:

2.4.2.1 AAMA Certification: Conformance with AW-PG50-H.

** NOTE TO SPECIFIER ** Delete configuration not required.

2.4.2.2 Configuration: Single hung bottom sash tilts in for glass cleaning.

2.4.2.3 Configuration: Single hung-to-single hung with continuous head and sill in one master frame; bottom sash tilts in for glass cleaning.

2.4.2.4 Configuration: Single hung-to-side fixed with continuous head and sill in one master frame; bottom sash tilts in for glass cleaning.

2.4.2.5 Configuration: Single hung-under-fixed with continuous jambs in one master frame; bottom sash tilts in for glass cleaning.

2.4.2.6 Configuration: Single hung-over-fixed with continuous jambs in one master frame; bottom sash tilts in for glass cleaning.

2.4.3 Product: Peerless GSH3 Single Hung Tilt Thermal Aluminum Window:

2.4.3.1 AAMA Certification: Conformance with AW-PG50-H.

** NOTE TO SPECIFIER ** Delete configuration not required.

2.4.3.2 Configuration: Single hung bottom sash tilts in for glass cleaning.

2.4.3.3 Configuration: Single hung-to-single hung with continuous head and sill in one master frame; bottom sash tilts in for glass cleaning.

2.4.3.4 Configuration: Single hung-to-side fixed with continuous head and sill in one master frame; bottom sash tilts in for glass cleaning.

2.4.3.5 Configuration: Single hung-under-fixed with continuous jambs in one master frame; bottom sash tilts in for glass cleaning.

2.4.3.6 Configuration: Single hung-over-fixed with continuous jambs in one master frame; bottom sash tilts in for glass cleaning.

2.4.4 Product: Peerless GDH5 Double Hung Tilt Thermal Aluminum Window:

2.4.4.1 AAMA Certification: Conformance with AW-PG50-H.

** NOTE TO SPECIFIER ** Delete configuration not required.

2.4.4.2 Configuration: Double hung both top and bottom sash tilt in for glass cleaning.

2.4.4.3 Configuration: Double hung-to-double hung with continuous head and sill in one master frame; both top and bottom sash tilt in for glass cleaning.

2.4.4.4 Configuration: Double hung-to-side fixed with continuous head and sill in one master frame; both top and bottom sash tilt in for glass cleaning.

2.4.4.5 Configuration: Double hung-under-fixed with continuous jambs in one master frame; both top and bottom sash tilt in for glass cleaning.

2.4.4.6 Configuration: Double hung-over-fixed with continuous jambs in one master frame; both top and bottom sash tilt in for glass cleaning.

2.4.5 Product: Peerless GDH3 Double Hung Tilt Thermal Aluminum Window:

2.4.5.1 AAMA Certification: Conformance with AW-PG50-H.

** NOTE TO SPECIFIER ** Delete configuration not required.

2.4.5.2 Configuration: Double hung both top and bottom sash tilt in for glass cleaning.

2.4.5.3 Configuration: Double hung-to-double hung with continuous head and sill in one master frame; both top and bottom sash tilt in for glass cleaning.

2.4.5.4 Configuration: Double hung-to-side fixed with continuous head and sill in one master frame; both top and bottom sash tilt in for glass cleaning.

2.4.5.5 Configuration: Double hung-under-fixed with continuous jambs in one master frame; both top and bottom sash tilt in for glass cleaning.

2.4.5.6 Configuration: Double hung-over-fixed with continuous jambs in one master frame; both top and bottom sash tilt in for glass cleaning.

** NOTE TO SPECIFIER ** Below construction provisions apply to both SH and DH G-Series window units.

2.4.6 Construction:

2.4.6.1 Aluminum Extrusions: Extruded by the window manufacturer from commercial quality 6063-T5 alloy; free from defects impairing strength and durability.

** NOTE TO SPECIFIER ** GSH3, GSH6, and GDH3 only. Delete if not required.

2.4.6.2 Windows: 3-1/4 inches (83 mm) frame depth; extruded aluminum with integral structural thermal break installed by the window manufacturer in the frame and sash members;

** NOTE TO SPECIFIER ** Delete construction not required.

2.4.6.2.1 Fabricated with equal-leg flange frame.

2.4.6.2.2 Fabricated with equal-leg prime/nailing fin frame.

** NOTE TO SPECIFIER ** GSH5 and GDH5 only. Delete if not required.

2.4.6.3 Windows: 4-1/4 inches (108 mm) frame depth; extruded aluminum with integral structural thermal break installed by the window manufacturer in the frame and sash members;

** NOTE TO SPECIFIER ** Delete construction not required.

2.4.6.3.1 Fabricated with equal-leg flange frame.

2.4.6.3.2 Fabricated with equal-leg prime/nailing fin frame.

2.4.6.4 Frame:Double tubular head, sill, and jambs miter cut and fastened with two zamac corner gussets per corner; two frame sill weep slots covered with weep flaps and weep hoods finished to match window; upturned interior sill leg with end caps to conceal cut edges; corners sealed by window manufacturer with sealant conforming to AAMA 800-10.

** NOTE TO SPECIFIER ** Single hung unit. Delete if not required.

2.4.6.4.1 SH units with tubular exterior fixed meeting rail fastened with two Zamac gussets per jamb without penetrating the jambs with fasteners.

2.4.6.5 Sash: Horizontal and vertical sash rails miter cut and fastened with one Zamac corner gusset per corner; corners sealed by window manufacturer with sealant conforming to AAMA 800-10.

** NOTE TO SPECIFIER ** Single hung unit. Delete if not required.

2.4.6.6 Sash Design: Continuous extruded lift rail on bottom sash interior with end caps to conceal cut edges; mechanical meeting rail interlock.

** NOTE TO SPECIFIER ** Double hung unit. Delete if not required.

2.4.6.7 Sash Design: Continuous extruded lift rail on the bottom rail of the lower sash interior with end caps to conceal cut edges; continuous extruded pull-down rail on the top rail of the upper sash interior with end caps to conceal cut edges; mechanical meeting rail interlock.

2.4.6.8 Exterior and interior finishes applied by the window manufacturer; frames and sash assembled by the window manufacturer.

2.4.6.9 Thermal Break: The thermal break separating the exterior and interior aluminum extrusions shall be a mechanical crimp-in-place system utilizing multi-directional glass fiber reinforced polyamide nylon struts with locking mechanical connections to the aluminum extrusions. The thermal break shall not be compromised by hardware or metal fasteners.

2.4.6.10 Glazing: exterior ExxonMobil Santoprene foam gasket; 1 inch (25 mm) insulating glass; two weep holes under each glass pocket for drainage; foam backer rod and silicone heel bead forming an internal seal; interior Santoprene bulb gasket threaded into aluminum glazing beads; glazed by the window manufacturer.

** NOTE TO SPECIFIER ** Single hung unit. Delete if not required.

2.4.6.11 Weatherstrip: Secured in extruded ports; pile with polypropylene center fin conforming to AAMA 701-11: single row on the sash-to-frame perimeter; Santoprene bulb seal conforming to AAMA 702-11: single row on the sash stiles-to-jamb and bottom rail-to-sill.

** NOTE TO SPECIFIER ** Double hung unit. Delete if not required.

2.4.6.12 Weatherstrip: Secured in extruded ports; pile with polypropylene center fin conforming to AAMA 701-11: single row on the sash stiles and single row at the meeting rails; Santoprene bulb seal conforming to AAMA 702-11: single row on the sash stiles and double row on the upper sash top rail and lower sash bottom rail.

** NOTE TO SPECIFIER ** Single hung unit. Delete if not required.

2.4.6.13 Hardware: two aluminum sill latches per window finished to match the window interior that automatically lock the window when the sash is closed; two tamper-resistant custodial tilt releases per sash that automatically engage the frame jamb when the sash is in its normal vertical position; two Zamac pivot bars per sash that engage the balance shoes when the sash is tilted parallel to the floor; two concealed Zamac wind locks that automatically engage the frame jamb when the sash is closed and automatically disengage the jamb when the sash is opened; two extruded aluminum sash stops with rubber bumpers which are painted to match the existing finish of the window and are installed above the lower sash and secured with screws on the jambs to prevent accidental removal.

** NOTE TO SPECIFIER ** Double hung unit. Delete if not required.

2.4.6.14 Hardware: two aluminum sill latches per window finished to match the window interior that automatically lock the window when the sash is closed; one aluminum head latch per window finished to match the window interior that automatically engages the frame head when the upper sash is closed; two tamper-resistant custodial tilt releases per sash that automatically engage the frame jamb when the sash are in their normal vertical position; two Zamac pivot bars per sash that engage the balance shoes when the sash are tilted parallel to the floor; two concealed Zamac wind locks per sash that automatically engage the frame jamb when the sash are closed and automatically disengage the jamb when the sash are opened; extruded aluminum sash stops with rubber bumpers which are painted to match the existing finish of the window and are secured with screws on the jambs to prevent accidental removal: two above the lower sash and two below the upper sash.

** NOTE TO SPECIFIER ** Single and double hung unit. Delete if not required.

2.4.6.15 Balances: Class 5 heavy duty spring conforming to AAMA 902-07; of appropriate capacity to hold sash stationary and permit smooth operation to operate freely; two nylon balance shoes with Zamac cams per sash which lock when the sash is tilted to prevent sash travel.

** NOTE TO SPECIFIER ** Delete if not required.

2.4.7 Insect Screens: Screen held on the window with interior plungers that automatically engage sockets in the frame jamb to resist exterior removal; 1 inch by 15/16 inch by .055 inch (25 mm by 24 mm by 1.4 mm) extruded tubular aluminum frame with the same finish as the window exterior; screen sill with two weep notches for drainage; corners mitered, gusset reinforced, and crimped.

** NOTE TO SPECIFIER ** Delete screen not required.

2.4.7.1 Half screen.

2.4.7.2 Full screen with extruded 3/8 inch by 3/4 inch by .062 inch (9.5 mm by 19 mm by 1.6 mm) horizontal cross bar.

** NOTE TO SPECIFIER ** Delete screen material not required.

2.4.7.3 18 x 16 dark fiberglass mesh; flexible PVC spline.

2.4.7.4 18 x 16 dark aluminum mesh; flexible PVC spline.

** NOTE TO SPECIFIER ** Below construction provisions apply to both SH and DH G-Series window units.

2.4.8 Performance:

2.4.8.1 AAMA Certification: Conformance with AAMA/WDMA/CSA 101/I.S.2/A440-08 when tests are performed on the prescribed 60 inches by 99 inches (1524 mm by 2515 mm) minimum test size with the following test results:

2.4.8.2 Air Infiltration: After the AAMA 910-10 life cycle test, not to exceed AAMA 101 standard of maximum 0.3 cfm/square foot when tested per ASTM E283-12 at a static air pressure difference of 6.24 psf.

2.4.8.3 Water Penetration: After the AAMA 910-10 life cycle test, no uncontrolled water leakage when tested per ASTM E331-09 and ASTM E547-09 at a static air pressure difference of 10 psf (low construction) and 12 psf (high construction).

2.4.8.4 Uniform Deflection: No more than L/175 when tested per ASTM E330-14 at a static air pressure difference of 50 psf.

2.4.8.5 Uniform Structural Load: No glass breakage or permanent damage to fasteners, and maximum .2% permanent deformation of the span of any frame member when tested per ASTM E330-14 at a static air pressure difference of 75 psf.

2.4.8.6 Forced-entry Resistance: Latching devices shall provide reasonable security against forced entry and the test window shall achieve a Level 10 when tested per ASTM F588-07.

2.4.9 Thermal AAMA Testing: Per AAMA 1503-09, on a 47 inches by 59 inches (1194 mm by 1499 mm) test size glazed with 1 inch (25 mm) insulating glass made with 1/4 inch (6 mm) soft coat low E coating on surface #2, plain air in the airspace made with a polymer-coated stainless steel spacer, and 1/4 inch (6 mm) clear glass, with the following test results:

** NOTE TO SPECIFIER ** GSH3 Single hung performance. Delete if not required.

2.4.9.1 Condensation Resistance Factor: minimum 69 frame CRF and 66 glass CRF.

2.4.9.2 Thermal Transmittance: maximum .42 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** GSH5 Single hung performance. Delete if not required.

2.4.9.3 Condensation Resistance Factor: minimum 67 frame CRF and 66 glass CRF.

2.4.9.4 Thermal Transmittance: maximum .44 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** GSH6 Single hung performance. Delete if not required.

2.4.9.5 Condensation Resistance Factor: minimum 53 frame CRF and 68 glass CRF.

2.4.9.6 Thermal Transmittance: maximum .46 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** GDH3 Double hung performance. Delete if not required.

2.4.9.7 Condensation Resistance Factor: minimum 62 frame CRF and 64 glass CRF.

2.4.9.8 Thermal Transmittance: maximum .46 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** GDH5 Double hung performance. Delete if not required.

2.4.9.9 Condensation Resistance Factor: minimum 63 frame CRF and 66 glass CRF.

2.4.9.10 Thermal Transmittance: maximum .45 btu/hr/sq.ft/degree F U value.

2.4.10 Thermal NFRC Testing: Per NFRC 102-2010 on a 47 inches by 59 inches (1194 mm by 1499 mm) test size glazed with 1 inch (25 mm) insulating glass made with 1/4 inch (25 mm) soft coat low E coating on surface #2, plain air in the airspace made with a polymer-coated stainless steel spacer, and 1/4 inch (6 mm) clear glass, with the following test result:

** NOTE TO SPECIFIER ** Single hung performance. Delete if not required.

2.4.10.1 Standardized Thermal Transmittance to be maximum GSH3 0.40 and GSH5 0.41 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Double hung performance. Delete if not required.

2.4.10.2 Standardized Thermal Transmittance to be maximum GDH3 0.44 and GDH5 0.43 btu/hr/sq.ft/degree F.

2.4.11 Thermal NFRC Simulation: Thermal computer simulation per NFRC 100-2010 on a 60 inch by 99 inches (1524 mm by 2515 mm) test size glazed with 1 inch (25 mm) insulating made with 1/4 inch (6 mm) soft coat low E coating on surface #2, argon gas in the airspace made with a polymer-coated stainless steel spacer, and 1/4 inch (6 mm) clear glass, with the following test result:

** NOTE TO SPECIFIER ** GSH3 Single hung performance. Delete if not required.

2.4.11.1 Standardized Thermal Transmittance to be maximum GSH3 0.347 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** GSH5 Single hung performance. Delete if not required.

2.4.11.2 Standardized Thermal Transmittance to be maximum GSH5 0.280 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** GSH6 Single hung performance. Delete if not required.

2.4.11.3 Standardized Thermal Transmittance to be maximum GSH6 0.383 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** GDH3 Double hung performance. Delete if not required.

2.4.11.4 Standardized Thermal Transmittance to be maximum GDH3 0.355 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** GDH5 Double hung performance. Delete if not required.

2.4.11.5 Standardized Thermal Transmittance to be maximum GDH5 0.299 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Architectural Series window units only. Delete if not required.

2.5 HUNG WINDOW UNITS - ARCHITECTURAL

** NOTE TO SPECIFIER ** Delete window not required.

2.5.1 Product: Peerless Products Series 9150-R Thermal Single Hung, Side Load Window.

2.5.1.1 AAMA Certification: Conformance with AW85.

2.5.2 Product: Peerless Products Series 4130-R Thermal Single Hung, Tilt Sash Window.

2.5.2.1 AAMA Certification: Conformance with AW50.

2.5.3 Construction:

2.5.3.1 Aluminum: Extruded aluminum shall be 6063-T5 alloy and tempered.

** NOTE TO SPECIFIER ** 9150-R only. Delete if not required.

2.5.3.2 Hardware: Primary sash locking hardware shall be of cast white bronze.

2.5.3.3 Hardware: Primary sash locking hardware shall of Zamac #3 alloy.

2.5.3.3.1 Tilt locking mechanism: Shall be of sufficient strength to meet applicable structural performance. The pivot bars shall be of solid stainless steel. No substitute materials will be accepted

2.5.3.4 Balances: Balances shall be tested in accordance with AAMA 902, "Voluntary Specification for Sash Balances.

** NOTE TO SPECIFIER ** Delete class not required.

2.5.3.4.1 Balances shall meet all minimum Class 1 requirements for operating force.

2.5.3.4.2 Balances shall meet all minimum Class 5 requirements for operating force.

2.5.3.5 Fasteners: Fasteners shall be aluminum, non-magnetic stainless steel or other materials warranted by the manufacturer to be non-corrosive and compatible with aluminum window members, trim, hardware, anchors and other components of the window units. Exposed fasteners shall not be permitted on exterior except where unavoidable for the application of hardware.

2.5.3.6 Weatherstrip: Provide double weather-stripping using silicone-coated woven pile with polypropylene fin center complying with AAMA 701.

2.5.3.7 Thermal Break: The thermal break separating the exterior and interior aluminum extrusions shall be a mechanical crimp-in-place system utilizing multi-directional glass fiber reinforced polyamide nylon struts with locking mechanical connections to the aluminum extrusions. The thermal break shall not be compromised by hardware or metal fasteners.

2.5.3.8 Glazing: Exterior ExxonMobil Santoprene foam gasket; 1 inch (25 mm) insulating glass; two weep holes under each glass pocket for drainage; foam backer rod and silicone heel bead forming an internal seal; interior Santoprene bulb gasket threaded into aluminum glazing beads; glazed by the window manufacturer.

2.5.3.9 Glazing beads shall be extruded aluminum and shall be of sufficient strength to retain the glass.

2.5.3.10 Fabrication:

2.5.3.10.1 Units shall be able to be re-glazed without dismantling the master or sash frame.

2.5.3.10.2 All aluminum frame and sash extrusions shall have a minimum wall thickness of 0.062 inch (1.6 mm).

** NOTE TO SPECIFIER ** 9150-R only. Delete if not required.

2.5.3.10.3 Sill of master frame shall have a minimum wall thickness of 0.094 inch (2.4 mm)

** NOTE TO SPECIFIER ** 4130-R only. Delete if not required.

2.5.3.10.4 Sill of master frame shall have a minimum wall thickness of 0.078 inch (2 mm)

2.5.3.10.5 Mechanical fasteners, welded components and hardware items shall not bridge thermal barriers. Thermal barriers shall align at all frame and sash corners.

2.5.3.11 Frame:

** NOTE TO SPECIFIER ** 4130-R series. Delete if not required.

2.5.3.11.1 Master frame shall be no less than 3-1/4 inches (83 mm).

** NOTE TO SPECIFIER ** 9150-R series. Delete if not required.

2.5.3.11.2 Master frame shall be no less than 4 inches (102 mm).

2.5.3.11.3 Frame components shall be mechanically fastened.

2.5.3.12 Sash:

2.5.3.12.1 Sash frame shall have a minimum wall thickness of 0.062 inch (1.6 mm).

2.5.3.12.2 Sash frame horizontal extrusions shall be of tubular design.

2.5.3.12.3 Sash corners shall be mechanically fastened.

2.5.4 Performance:

2.5.4.1 AAMA Certification: Conformance with AAMA/WDMA/CSA 101/I.S.2/A440-08 when tests are performed on the prescribed test size with the following test results:

** NOTE TO SPECIFIER ** 4130-R and 9150-R. Delete if not required.

2.5.4.2 Air Infiltration: Not to exceed AAMA 101 standard of maximum 0.3 cfm/square foot when tested per ASTM E283-04 at a static air pressure difference of 6.24 psf.

** NOTE TO SPECIFIER ** 4130-R. Delete if not required.

2.5.4.3 Water Penetration: No uncontrolled water leakage when tested per ASTM E331-09 and ASTM E547-09 at a static air pressure difference of 10 psf.

** NOTE TO SPECIFIER ** 9150-R. Delete if not required.

2.5.4.4 Water Penetration: No uncontrolled water leakage when tested per ASTM E331-09 and ASTM E547-09 at a static air pressure difference of 12 psf.

2.5.4.5 Uniform Structural Load: There shall be no glass breakage, permanent damage to fasteners, hardware parts, support arms or actuating mechanisms or any other damage that would cause the window to be inoperable. There shall be no permanent deformation of any main frame, sash, panel or sash member in excess of L/175 of its span.

** NOTE TO SPECIFIER ** 4130-R. Delete if not required.

2.5.4.5.1 Tested at a positive and negative static air pressure difference of 75 psf per ASTM E330.

** NOTE TO SPECIFIER ** 9150-R. Delete if not required.

2.5.4.5.2 Tested at a positive and negative static air pressure difference of 127.5 psf per ASTM E330.

** NOTE TO SPECIFIER ** Delete if not required.

2.6 PROJECTED WINDOW UNITS - ENERGSAVE ARCHITECTURAL

** NOTE TO SPECIFIER ** Delete window not required.

2.6.1 Product: Peerless G701 Project-Out Thermal Aluminum Window.

2.6.1.1 AAMA Certification: Conformance with AP-AW90.

2.6.2 Product: Peerless G601 Project-Out Thermal Aluminum Window.

2.6.2.1 AAMA Certification: Conformance with AP-AW100.

2.6.3 Product: Peerless G501 Project-Out Thermal Aluminum Window.

2.6.3.1 AAMA Certification: Conformance with AP-AW100.

2.6.4 Product: Peerless G401 Project-Out Thermal Aluminum Window.

2.6.4.1 AAMA Certification: Conformance with AP-AW100.

2.6.5 Product: Peerless G301 Project-Out Thermal Aluminum Window.

2.6.5.1 AAMA Certification: Conformance with AP-AW100.

2.6.6 Product: Peerless G201 Project-Out Thermal Aluminum Window.

2.6.6.1 AAMA Certification: Conformance with AP-AW100.

2.6.7 Product: Peerless G101 Project-Out Thermal Aluminum Window.

2.6.7.1 AAMA Certification: Conformance with AP-AW100.

2.6.8 Project-Out Configuration:

** NOTE TO SPECIFIER ** Delete configuration not required.

2.6.8.1 Project out vent; vent hinged at the top and pushes out from the bottom to open.

2.6.8.2 Vent-to-vent with a vertical integral mullion in one master frame; vent hinged at the top and pushes out from the bottom to open.

2.6.8.3 Vent-to-fixed with a vertical integral mullion in one master frame; vent hinged at the top and pushes out from the bottom to open.

2.6.8.4 Vent-under-vent with a horizontal integral mullion in one master frame; vent hinged at the top and pushes out from the bottom to open.

2.6.8.5 Vent-under-fixed with a horizontal integral mullion in one master frame; vent hinged at the top and pushes out from the bottom to open.

2.6.8.6 Vent-over-fixed with a horizontal integral mullion in one master frame; vent hinged at the top and pushes out from the bottom to open.

** NOTE TO SPECIFIER ** Delete window not required.

2.6.9 Product: Peerless G711 Project-in Thermal Aluminum Window.

2.6.9.1 AAMA Certification: Conformance with AP-AW100.

2.6.10 Product: Peerless G611 Project-in Thermal Aluminum Window.

2.6.10.1 AAMA Certification: Conformance with AP-AW100.

2.6.11 Product: Peerless G511 Project-in Thermal Aluminum Window.

2.6.11.1 AAMA Certification: Conformance with AP-AW100.

2.6.12 Product: Peerless G411 Project-in Thermal Aluminum Window.

2.6.12.1 AAMA Certification: Conformance with AP-AW100.

2.6.13 Product: Peerless G311 Project-in Thermal Aluminum Window.

2.6.13.1 AAMA Certification: Conformance with AP-AW100.

2.6.14 Product: Peerless G211 Project-in Thermal Aluminum Window.

2.6.14.1 AAMA Certification: Conformance with AP-AW100.

2.6.15 Product: Peerless G111 Project-in Thermal Aluminum Window.

2.6.15.1 AAMA Certification: Conformance with AP-AW100.

2.6.16 Project-In Configuration:

** NOTE TO SPECIFIER ** Delete configuration not required.

2.6.16.1 Project-In vent; vent hinged at the bottom and pulls in from the top to open.

2.6.16.2 Vent-to-vent with a vertical integral mullion in one master frame; vent hinged at the bottom and pulls in from the top to open.

2.6.16.3 Vent-to-fixed with a vertical integral mullion in one master frame; vent hinged at the bottom and pulls in from the top to open.

2.6.16.4 Vent-under-vent with a horizontal integral mullion in one master frame; vent hinged at the bottom and pulls in from the top to open.

2.6.16.5 Vent-under-fixed with a horizontal integral mullion in one master frame; vent hinged at the bottom and pulls in from the top to open.

2.6.16.6 Vent-over-fixed with a horizontal integral mullion in one master frame; vent hinged at the bottom and pulls in from the top to open.

2.6.17 Construction:

** NOTE TO SPECIFIER ** Provisions below apply to both Peerless Project-Out and Peerless Project-In vent thermal aluminum window.

2.6.17.1 Aluminum Extrusions: Extruded by the window manufacturer from commercial quality 6063-T5 alloy; free from defects impairing strength and durability.

** NOTE TO SPECIFIER ** Peerless G701 Project-Out and Peerless G711 Project-In. Delete if not required.

2.6.17.2 Frame: Single tubular head, sill, and jambs miter cut and fastened with one Zamac corner gusset per corner; tubular integral mullion, if required, fastened with one Zamac gusset per frame member without penetrating the frame member with fasteners; corners sealed by the window manufacturer with sealant conforming to AAMA 800-10.

** NOTE TO SPECIFIER ** Peerless G101 Project-Out, Peerless G201 Project-Out, Peerless G301 Project-Out, Peerless G401 Project-Out, Peerless G501 Project-Out, Peerless G601 Project-Out, Peerless G111 Project-In, Peerless G211 Project-In, Peerless G311 Project-In, Peerless G411 Project-In, Peerless G511 Project-In, and Peerless G611 Project-In. Delete if not required.

2.6.17.3 Frame: Double tubular head, sill, and jambs miter cut and fastened with two zamac corner gussets per corner; double tubular integral mullion, if required, fastened with two zamac gussets per frame member without penetrating the frame member with fasteners; corners sealed by the window manufacturer with sealant conforming to AAMA 800-10.

** NOTE TO SPECIFIER ** Peerless G101 Project-Out, Peerless G201 Project-Out, Peerless G301 Project-Out, Peerless G401 Project-Out, Peerless G501 Project-Out, Peerless G601 Project-Out, Peerless G111 Project-In, Peerless G211 Project-In, Peerless G311 Project-In, Peerless G411 Project-In Peerless G511 Project-In, and Peerless G611 Project-In. Delete if not required.

2.6.17.4 Vents: Double tubular horizontal and vertical vent rails and stiles miter cut and fastened with two zamac corner gussets per corner; corners sealed by window manufacturer with sealant conforming to AAMA 800-10.

** NOTE TO SPECIFIER ** Peerless G701 Project-Out and Peerless G711 Project-In. Delete if not required.

2.6.17.5 Vents: Double tubular horizontal and vertical vent rails and stiles miter cut and fastened with one Zamac corner gusset per corner; corners sealed by window manufacturer with sealant conforming to AAMA 800-10.

** NOTE TO SPECIFIER ** Peerless G401 Project-Out and Peerless G411 Project-In. Delete if not required.

2.6.17.6 Interior take-out panel: horizontal bottom lift rail, top rail, and both vertical stiles miter cut and fastened with one stainless steel screw per corner for easy reglazing; unauthorized removal of the panel restricted with two tamperproof screws.

2.6.17.7 Water Control: Continuous compression gasket to utilize pressure equalization and to allow water to drain by gravity.

2.6.17.8 Window Frame: Extruded aluminum with integral structural thermal break installed by the window manufacturer in the frame and vent members; exterior and interior finishes applied by the window manufacturer; frames and vents assembled by the window manufacturer.

** NOTE TO SPECIFIER ** Peerless G701 Project-Out and Peerless G711 Project-In. Delete if not required.

2.6.17.8.1 Frame Depth: 2 inches (51 mm).

** NOTE TO SPECIFIER ** Peerless G101 Project-Out and Peerless G111 Project-In. Delete if not required.

2.6.17.8.2 Frame Depth: 2-1/2 inches (64 mm).

** NOTE TO SPECIFIER ** Peerless G201 Project-Out, Peerless G301 Project-Out, G401 Project-Out, G601 Project-Out, Peerless G211 Project-In, Peerless G311 Project-In, Peerless G411 Project-In, and Peerless G611 Project-In. Delete if not required.

2.6.17.8.3 Frame Depth: 3-1/4 inches (83 mm).

** NOTE TO SPECIFIER ** Peerless G501 Project-Out and Peerless G511 Project-In. Delete if not required.

2.6.17.8.4 Frame Depth: 4-1/4 inches (108 mm).

** NOTE TO SPECIFIER ** Delete construction not required.

2.6.17.8.5 Fabricated with equal-leg flange frame.

2.6.17.8.6 Fabricated with equal-leg prime/nailing fin frame.

2.6.17.9 Thermal Break: The thermal break separating the exterior and interior aluminum extrusions shall be a mechanical crimp-in-place system utilizing multi-directional glass fiber reinforced polyamide nylon struts with locking mechanical connections to the aluminum extrusions. The thermal break shall not be compromised by hardware or metal fasteners.

2.6.17.10 Glazing: Exterior ExxonMobil Santoprene foam gasket, 1 inch (13 mm) insulating glass, two weep holes under each glass pocket for drainage, foam backer rod and silicone heel bead forming an internal seal, interior Santoprene bulb gasket threaded into aluminum glazing beads; 1/4 inch (6 mm) glass; glazed by the window manufacturer.

** NOTE TO SPECIFIER ** Projected-Out unit. Delete if not required.

2.6.17.11 Weatherstrip: Secured in extruded ports; Santoprene bulb seal conforming to AAMA 702-11: single row on the vent bottom rail and double rows on the vent top rail and vent stiles.

** NOTE TO SPECIFIER ** Projected-In unit. Delete if not required.

2.6.17.12 Weatherstrip: Secured in extruded ports; Santoprene seals conforming to AAMA 702-11; flap seal single row mounted on the vent interior on the bottom rail, top rail, and stiles; center vent gasket seal single internal row mounted on the head, sill and jamb frame members.

** NOTE TO SPECIFIER ** Projected-In and Project-Out units.

2.6.17.13 Hardware: Mounted in concealed extruded grooves to avoid penetrating frame or vent members with fasteners; two concealed stainless steel hinges conforming to AAMA 904-09 per vent to rotate the vent on horizontal axis;

** NOTE TO SPECIFIER ** Delete handle not required.

2.6.17.13.1 One single-action neutral finish handle with multiple point locks per vent.

2.6.17.13.2 One single-action white finish handle with multiple point locks per vent.

2.6.17.13.3 One single-action satin nickel handle with multiple point locks per vent.

2.6.17.13.4 One single-action black handle with multiple point locks per vent.

2.6.17.13.5 One key-operated black handle with multiple point locks per vent.

2.6.17.13.6 One key-operated white handle with multiple point locks per vent.

2.6.17.13.7 One custodial-operated satin nickel handle with multiple point locks per vent and security wrench tool.

2.6.17.13.8 One custodial-operated black handle with multiple point locks per vent and security wrench tool.

2.6.17.13.9 One custodial-operated white handle with multiple point locks per vent and security wrench tool.

2.6.17.13.10 One custodial-operated neutral handle with multiple point locks per vent and security wrench tool.

** NOTE TO SPECIFIER ** Project-Out options only. Specify clear opening dimension for limit arms. Delete if not required.

2.6.17.13.11 Key-release limit arms with clear opening dimension of ___.

2.6.17.13.12 Scissor-arm operator.

2.6.18 Performance:

2.6.18.1 Conformance when tests are performed on a 60 inches by 36 inches (1524 mm by 914 mm) minimum test size with the following test results:

2.6.18.2 Air Infiltration: Not to exceed the standard of maximum 0.1 cfm/square foot when tested per ASTM E283-12 at a static air pressure difference of 6.24 psf.

2.6.18.3 Water Penetration: No uncontrolled water leakage when tested per ASTM E331-09 and ASTM E547-09 at a static air pressure difference of 15 psf.

** NOTE TO SPECIFIER ** Peerless G701 Project-Out. Delete if not required.

2.6.18.4 Uniform Deflection: No more than L/175 when tested per ASTM E330-14 at a static air pressure difference of 90 psf.

** NOTE TO SPECIFIER ** Peerless G101 Project-Out, Peerless G201 Project-Out, Peerless G301 Project-Out, Peerless G401 Project-Out, Peerless G501 Project-Out, Peerless G601 Project-Out, Peerless G111 Project-In, Peerless G211 Project-In, Peerless G311 Project-In, Peerless G411 Project-In, Peerless G511 Project-In, Peerless G611 Project-In, and Peerless G711 Project-In. Delete if not required.

2.6.18.5 Uniform Deflection: No more than L/175 when tested per ASTM E330-14 at a static air pressure difference of 100 psf.

** NOTE TO SPECIFIER ** Peerless G701 Project-Out. Delete if not required.

2.6.18.6 Uniform Structural Load: No glass breakage or permanent damage to fasteners, and maximum .2% permanent deformation of the span of any frame member when tested per ASTM E330-14 at a static air pressure difference of 135 psf.

** NOTE TO SPECIFIER ** Peerless G101 Project-Out, Peerless G201 Project-Out, Peerless G301 Project-Out, Peerless G401 Project-Out, Peerless G501 Project-Out, Peerless G601 Project-Out, Peerless G111 Project-In, Peerless G211 Project-In, Peerless G311 Project-In, Peerless G411 Project-In, Peerless G511 Project-In, Peerless G611 Project-In, and Peerless G711 Project-In. Delete if not required.

2.6.18.7 Uniform Structural Load: No glass breakage or permanent damage to fasteners, and maximum .2% permanent deformation of the span of any frame member when tested per ASTM E330-14 at a static air pressure difference of 150 psf.

2.6.18.8 Forced-Entry Resistance: Latching devices shall provide reasonable security against forced entry and the test window shall achieve a Grade 40 when tested per ASTM F588-07.

2.6.19 Thermal NFRC Simulation: Thermal computer simulation per NFRC 100-2010 on a 60 inches by 36 inches (1524 mm by 914 mm) test size glazed with 1 inch (25 mm) insulating made with 1/4 inch (6 mm) soft coat low E coating on surface #2, argon gas in the airspace made with a polymer-coated stainless steel spacer, and 1/4 inch (6 mm) clear glass, with the following test result:

** NOTE TO SPECIFIER ** Peerless G101 Project-Out. Delete if not required.

2.6.19.1 Standardized Thermal Transmittance to be maximum 0.394 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G111 Project-In. Delete if not required.

2.6.19.2 Standardized Thermal Transmittance to be maximum 0.400 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G201 Project-Out. Delete if not required.

2.6.19.3 Standardized Thermal Transmittance to be maximum 0.363 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G211 Project-In. Delete if not required.

2.6.19.4 Standardized Thermal Transmittance to be maximum 0.375 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G301 Project-Out. Delete if not required.

2.6.19.5 Standardized Thermal Transmittance to be maximum 0.334 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G311 Project-In. Delete if not required.

2.6.19.6 Standardized Thermal Transmittance to be maximum 0.346 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G401 Project-Out. Delete if not required.

2.6.19.7 Standardized Thermal Transmittance to be maximum 0.281 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G411 Project-In. Delete if not required.

2.6.19.8 Standardized Thermal Transmittance to be maximum 0.290 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G601 Project-Out. Delete if not required.

2.6.19.9 Standardized Thermal Transmittance to be maximum 0.392 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G611 Project-In. Delete if not required.

2.6.19.10 Standardized Thermal Transmittance to be maximum 0.343 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G701 Project-Out. Delete if not required.

2.6.19.11 Standardized Thermal Transmittance to be maximum 0.384 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G711 Project-In. Delete if not required.

2.6.19.12 Standardized Thermal Transmittance to be maximum 0.366 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G501 Project-Out and Peerless G511 Project-In. Delete if not required.

2.6.20 Thermal NFRC Simulation: Thermal computer simulation per NFRC 100-2010 on a 60 inches by 36 inches (1524 mm by 914 mm) test size glazed with 1-3/4 inches (44.5 mm) triple insulating glass made with exterior 1/4 inch (6 mm) glass with a soft coat low E coating on surface #2, argon gas in the airspace made with a polymer-coated stainless steel spacer, internal 1/4 inch (6 mm) clear glass, argon in the airspace made with a polymer-coated stainless steel spacer, and interior 1/4 inch (6 mm) glass with a soft coat low E coating on surface #5, with the following test result:

** NOTE TO SPECIFIER ** Peerless G501 Project-Out. Delete if not required.

2.6.20.1 Standardized Thermal Transmittance to be maximum 0.237 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G511 Project-In. Delete if not required.

2.6.20.2 Standardized Thermal Transmittance to be maximum 0.19 btu/hr/sq.ft/degree F.

2.6.21 Thermal AAMA Testing: per AAMA 1503-09, on a 59 inches by 24 inches (1499 mm by 610 mm) test size glazed with 1 inch (25 mm) insulating glass made with 1/4 inch (6 mm) soft coat low E coating on surface #2, plain air in the airspace made with a polymer-coated stainless steel spacer, and 1/4 inch (6 mm) clear glass, with the following test results:

** NOTE TO SPECIFIER ** Peerless G101 Project-Out. Delete if not required.

2.6.21.1 Condensation Resistance Factor: minimum 60 frame CRF and 66 glass CRF.

2.6.21.2 Thermal Transmittance: maximum 0.51 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G111 Project-In. Delete if not required.

2.6.21.3 Condensation Resistance Factor: minimum 57 frame CRF and 66 glass CRF.

2.6.21.4 Thermal Transmittance: maximum 0.47 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G201 Project-Out. Delete if not required.

2.6.21.5 Condensation Resistance Factor: minimum 67 frame CRF and 67 glass CRF.

2.6.21.6 Thermal Transmittance: maximum 0.46 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G211 Project-In. Delete if not required.

2.6.21.7 Condensation Resistance Factor: minimum 66 frame CRF and 67 glass CRF.

2.6.21.8 Thermal Transmittance: maximum 0.45 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G301 Project-Out. Delete if not required.

2.6.21.9 Condensation Resistance Factor: minimum 70 frame CRF and 67 glass CRF.

2.6.21.10 Thermal Transmittance: maximum 0.43 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G311 Project-In. Delete if not required.

2.6.21.11 Condensation Resistance Factor: minimum 73 frame CRF and 67 glass CRF.

2.6.21.12 Thermal Transmittance: maximum 0.38 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G401 Project-Out. Delete if not required.

2.6.21.13 Condensation Resistance Factor: minimum 70 frame CRF and 67 glass CRF.

2.6.21.14 Thermal Transmittance: maximum 0.43 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G411 Project-In. Delete if not required.

2.6.21.15 Condensation Resistance Factor: minimum 73 frame CRF and 67 glass CRF.

2.6.21.16 Thermal Transmittance: maximum 0.38 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G611 Project-In. Delete if not required.

2.6.21.17 Condensation Resistance Factor: minimum 69 frame CRF and 68 glass CRF.

2.6.21.18 Thermal Transmittance: maximum 0.42 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G711 Project-In. Delete if not required.

2.6.21.19 Condensation Resistance Factor: minimum 57 frame CRF and 70 glass CRF.

2.6.21.20 Thermal Transmittance: maximum 0.44 btu/hr/sq.ft/degree F U value.

** NOTE TO SPECIFIER ** Peerless G511 Project-In. Delete if not required.

2.6.22 Thermal AAMA Testing: per AAMA 1503-09, on a 59 inches by 32 inches (1499 mm by 813 mm) test size glazed with 1 3/4 inch (44 mm) insulating glass made with 1/4 inch (6 mm) soft coat low E coating on surface #2, plain air in the airspace made with a stainless steel spacer, 1/4 inch clear glass, plain air in the airspace made with a stainless steel spacer, and 1/4 inch (6 mm) soft coat low E coating on surface #5, with the following test results:

2.6.22.1 Condensation Resistance Factor: minimum 83 frame CRF and 83 glass CRF.

2.6.22.2 Thermal Transmittance: maximum 0.19 btu/hr/sq.ft/degree F U value.

2.6.23 Thermal NFRC Testing: per NFRC 102-2010 on a 59 inches by 24 inches (1499 mm by 610 mm) test size glazed with 1 inch (25 mm) insulating glass made with 1/4 inch (6 mm) soft coat low E coating on surface #2, plain air in the airspace made with a polymer-coated stainless steel spacer, and 1/4 inch (6 mm) clear glass, with the following test result:

** NOTE TO SPECIFIER ** Peerless G101 Project-Out. Delete if not required.

2.6.23.1 Standardized Thermal Transmittance to be maximum 0.45 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G111 Project-In. Delete if not required.

2.6.23.2 Standardized Thermal Transmittance to be maximum 0.43 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G201 Project-Out. Delete if not required.

2.6.23.3 Standardized Thermal Transmittance to be maximum 0.45 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G211 Project-In. Delete if not required.

2.6.23.4 Standardized Thermal Transmittance to be maximum 0.44 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G301 Project-Out. Delete if not required.

2.6.23.5 Standardized Thermal Transmittance to be maximum 0.43 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G311 Project-In. Delete if not required.

2.6.23.6 Standardized Thermal Transmittance to be maximum 0.38 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G401 Project-Out. Delete if not required.

2.6.23.7 Standardized Thermal Transmittance to be maximum 0.43 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G411 Project-In. Delete if not required.

2.6.23.8 Standardized Thermal Transmittance to be maximum 0.38 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G611 Project-In. Delete if not required.

2.6.23.9 Standardized Thermal Transmittance to be maximum 0.42 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G711 Project-In. Delete if not required.

2.6.23.10 Standardized Thermal Transmittance to be maximum 0.43 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G511 Project-In. Delete if not required.

2.6.24 Thermal NFRC Testing: per NFRC 102-2010 on a 59 inches by 32 inches (1499 mm by 813 mm) test size glazed with 1 3/4 inch (44 mm) insulating glass made with 1/4 inch (6 mm) soft coat low E coating on surface #2, 90% Argon in the airspace made with a stainless steel spacer, 1/4 inch (6 mm) clear glass, 90% Argon in the airspace made with a stainless steel spacer, 1/4 inch (6 mm) soft coat low E coating on surface #5 with the following test result:

2.6.24.1 Standardized Thermal Transmittance to be maximum 0.19 btu/hr/sq.ft/degree F.

** NOTE TO SPECIFIER ** Peerless G401 Project-Out. Delete if not required.

2.6.25 Acoustical Performance: Testing per ASTM E90-09 on a 46-1/4 inches (1175 mm) by 59 inches (1499 mm) vent-under-fixed test size triple glazed with exterior 1 inch (25 mm) insulating glass made with exterior 1/4 inch (6 mm) monolithic glass by 9/16 inch (14 mm) airspace by interior 3/16 inch (4.8 mm) monolithic glass, and interior single glazed with 1/4 inch (6 mm) laminated glass - 1/8 inch (3 mm) glass by .030 inch (0.76 mm) PVB interlayer by 1/8 inch (3 mm) glass: Minimum 45 STC and 35 OITC.

** NOTE TO SPECIFIER ** Peerless G411 Project-In. Delete if not required.

2.6.26 Acoustical Performance: Testing per ASTM E90-09 on a 46-1/4 inches (1175 mm) by 59 inches (1499 mm) vent-under-fixed test size triple glazed with exterior 1 inch (25 mm) insulating glass made with exterior 1/4 inch (6 mm) monolithic glass by 9/16 inch (14 mm) airspace by interior 3/16 inch (4.8 mm) monolithic glass, and interior single glazed with 1/4 inch (6 mm) monolithic glass: Minimum 43 STC and 34 OITC.

** NOTE TO SPECIFIER ** ENERGSAVE G-Series Casement Windows only. Delete if not required.

2.7 CASEMENT WINDOW UNITS - ENERGSAVE ARCHITECTURAL

** NOTE TO SPECIFIER ** Delete window not required.

2.7.1 Product: Peerless G751 Left Hand Casement Outswing Thermal Aluminum Window.

2.7.1.1 AAMA Certification: Conformance with C-AW100.

2.7.2 Product: Peerless G755 Right Hand Casement Outswing Thermal Aluminum Window.

2.7.2.1 AAMA Certification: Conformance with C-AW100.

2.7.3 Product: Peerless G651 Left Hand Casement Outswing Thermal Aluminum Window.

2.7.3.1 AAMA Certification: Conformance with C-AW90.

2.7.4 Product: Peerless G655 Right Hand Casement Outswing Thermal Aluminum Window.

2.7.4.1 AAMA Certification: Conformance with C-AW90.

2.7.5 Product: Peerless G551 Left Hand Casement Outswing Thermal Aluminum Window.

2.7.5.1 AAMA Certification: Conformance with C-AW100.

2.7.6 Product: Peerless G555 Right Hand Casement Outswing Thermal Aluminum Window.

2.7.6.1 AAMA Certification: Conformance with C-AW100.

2.7.7 Product: Peerless G451 Left Hand Casement Outswing Thermal Aluminum Window.

2.7.7.1 AAMA Certification: Conformance with C-AW100.

2.7.8 Product: Peerless G455 Right Hand Casement Outswing Thermal Aluminum Window.

2.7.8.1 AAMA Certification: Conformance with C-AW100.

2.7.9 Product: Peerless G351 Left Hand Casement Outswing Thermal Aluminum Window.

2.7.9.1 AAMA Certification: Conformance with C-AW100.

2.7.10 Product: Peerless G355 Right Hand Casement Outswing Thermal Aluminum Window.

2.7.10.1 AAMA Certification: Conformance with C-AW100.

2.7.11 Product: Peerless G251 Left Hand Casement Outswing Thermal Aluminum Window.

2.7.11.1 AAMA Certification: Conformance with C-AW100.

2.7.12 Product: Peerless G255 Right Hand Casement Outswing Thermal Aluminum Window.

2.7.12.1 AAMA Certification: Conformance with C-AW100.

2.7.13 Product: Peerless G151 Left Hand Casement Outswing Thermal Aluminum Window.

2.7.13.1 AAMA Certification: Conformance with C-AW100.

2.7.14 Product: Peerless G155 Right Hand Casement Outswing Thermal Aluminum Window.

2.7.14.1 AAMA Certification: Conformance with C-AW100.

2.7.15 Casement Outswing Configuration:

** NOTE TO SPECIFIER ** Delete configuration not required.

2.7.15.1 Vent hinged at the jamb and pushes out to open.

2.7.15.2 Vent-to-vent with a vertical integral mullion in one master frame; vent hinged at the jamb and pushes out to open.

2.7.15.3 Vent-to-fixed with a vertical integral mullion in one master frame; vent hinged at the jamb and pushes out to open.

2.7.15.4 Vent-under-fixed with a horizontal integral mullion in one master frame; vent hinged at the jamb and pushes out to open.

2.7.15.5 Vent-over-fixed with a horizontal integral mullion in one master frame; vent hinged at the jamb and pushes out to open.

** NOTE TO SPECIFIER ** Delete window not required.

2.7.16 Product: Peerless G761 Left Hand Casement Inswing Thermal Aluminum Window.

2.7.16.1 AAMA Certification: Conformance with C-AW100.

2.7.17 Product: Peerless G765 Right Hand Casement Inswing Thermal Aluminum Window.

2.7.17.1 AAMA Certification: Conformance with C-AW100.

2.7.18 Product: Peerless G661 Left Hand Casement Inswing Thermal Aluminum Window.

2.7.18.1 AAMA Certification: Conformance with C-AW100.

2.7.19 Product: Peerless G665 Right Hand Casement Inswing Thermal Aluminum Window.

2.7.19.1 AAMA Certification: Conformance with C-AW100.

2.7.20 Product: Peerless G561 Left Hand Casement Inswing Thermal Aluminum Window.

2.7.20.1 AAMA Certification: Conformance with C-AW80.

2.7.21 Product: Peerless G565 Right Hand Casement Inswing Thermal Aluminum Window.

2.7.21.1 AAMA Certification: Conformance with C-AW80.

2.7.22 Product: Peerless G461 Left Hand Casement Inswing Thermal Aluminum Window.

2.7.22.1 AAMA Certification: Conformance with C-AW80.

2.7.23 Product: Peerless G465 Right Hand Casement Inswing Thermal Aluminum Window.

2.7.23.1 AAMA Certification: Conformance with C-AW80.

2.7.24 Product: Peerless G361 Left Hand Casement Inswing Thermal Aluminum Window.

2.7.24.1 AAMA Certification: Conformance with C-AW80.

2.7.25 Product: Peerless G365 Right Hand Casement Inswing Thermal Aluminum Window.

2.7.25.1 AAMA Certification: Conformance with C-AW80.

2.7.26 Product: Peerless G261 Left Hand Casement Inswing Thermal Aluminum Window.

2.7.26.1 AAMA Certification: Conformance with C-AW80.

2.7.27 Product: Peerless G265 Right Hand Casement Inswing Thermal Aluminum Window.

2.7.27.1 AAMA Certification: Conformance with C-AW80.

2.7.28 Product: Peerless G161 Left Hand Casement Inswing Thermal Aluminum Window.

2.7.28.1 AAMA Certification: Conformance with C-AW80.

2.7.29 Product: Peerless G165 Right Hand Casement Inswing Thermal Aluminum Window.

2.7.29.1 AAMA Certification: Conformance with C-AW80.

2.7.30 Casement Inswing Configuration:

** NOTE TO SPECIFIER ** Delete configuration not required.

2.7.30.1 Vent hinged at the jamb and pulls in to open.

2.7.30.2 Vent-to-vent with a vertical integral mullion in one master frame; vent hinged at the jamb and pulls in to open.

2.7.30.3 Vent-to-fixed with a vertical integral mullion in one master frame; vent hinged at the jamb and pulls in to open.

2.7.30.4 Vent-under-fixed with a horizontal integral mullion in one master frame; vent hinged at the jamb and pulls in to open.

2.7.30.5 Vent-over-fixed with a horizontal integral mullion in one master frame; vent hinged at the jamb and pulls in to open.

2.7.31 Construction:

2.7.31.1 Aluminum Extrusions: Extruded by the window manufacturer from commercial quality 6063-T5 alloy; free from defects impairing strength and durability.

** NOTE TO SPECIFIER ** Peerless G751-55 Out-Swing and Peerless G761-65 In-Swing. Delete if not required.

2.7.31.2 Frame: Single tubular head, sill, and jambs miter cut and fastened with one Zamac corner gusset per corner; tubular integral mullion, if required, fastened with one Zamac gusset per frame member without penetrating the frame member with fasteners; corners sealed by the window manufacturer with sealant conforming to AAMA 800-10.

2.7.31.3 Vents: Double tubular horizontal and vertical vent rails and stiles miter cut and fastened with one zamac corner gusset per corner; corners sealed by window manufacturer with sealant conforming to AAMA 800-10.

** NOTE TO SPECIFIER ** Peerless G151-55 Out-Swing, Peerless G251-55 Out-Swing, Peerless G351-55 Out-Swing, Peerless G451-55 Out-Swing, Peerless G551-55 Out-Swing, Peerless G651-55 Out-Swing, Peerless G161-65 In-Swing, Peerless G261-65 In-Swing, Peerless G361-65 In-Swing, Peerless G461-65 In-Swing, Peerless G561-65 In-Swing, and Peerless G661-65 In-Swing. Delete if not required.

2.7.31.4 Frame: Double tubular head, sill, and jambs miter cut and fastened with two Zamac corner gussets per corner; double tubular integral mullion, if required, fastened with two Zamac gussets per frame member without penetrating the frame member with fasteners; corners sealed by the window manufacturer with sealant conforming to AAMA 800-10.

2.7.31.5 Vents: Double tubular horizontal and vertical vent rails and stiles miter cut and fastened with two zamac corner gussets per corner; corners sealed by window manufacturer with sealant conforming to AAMA 800-10.

** NOTE TO SPECIFIER ** Peerless G451-55 Out-Swing and Peerless G461-65 In-S