Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
3402 PICO BLVD
ARCHITECTURAL REVIEW BOARD
SANTA MONICA, CA 90405APRIL 10, 2017
SUPPLEMENTAL PACKAGE
F.P.S.C.
F.P
.S.C
.
F.P.S.C.F.P.S.C.
DN
DN
S CENTINELA AVE
34TH ST
PIC
O B
LVD
3402 PICO BLVD
LINE OF FREEWAY EDGE ABOVE
PROPERTY LINE(E) BALCONY OVERHANG
NORTH ENTRY
(E) BIKE SHARE
I-10 FREEWAYABOVE
(E) LINE OF SIDEWALK
RAM
P
EAST ENTRY
(E) RAMP(E) MECH
AREA
(N) SUNKEN COURTYARD
(E) BIKE PARKING
(E) WEST ENTRY STAIR
(E) SITE WALL WITH GATE
SID
EWAL
K
(E) STAIR TO CALTRANS LOT
(E) CONCRETE SIDEWALK
NEW PERGOLASEATING AREA
LANDSCAPED AREA
LANDSCAPED AREA
NEW SOLAR CANOPY STRUCTURES ABOVE PARKING SPACESPARKING
ATRIUM/COURTYARD
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
16
1718
1920
2122
2324
25
2627
2829
3031
3233
3435
3637
3839
40
41 42 43 44 45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
73
72
71
70
69
68
67
66
65
64
63
62
61
80
79
78
77
76
75
7481828384
8586
87
(N) SEATING AREA
(E) LIGHT POST
87 EXISTING SPACES ON-SITE
(E) SIDEWALK
LANDSCAPEDAREA
(E) FIRE DEPT CONNECTION
(E) MECHANICAL ENCLOSURE
CALTRANS LOT PARKING
68 EXISTING SPACES OFF-SITE
PROPERTY LINE
(E) DRIVEWAY
(E) GATE
NEW STAIRS
NEW RAMPNEW LANDSCAPING
(N) R
AMP
(N) EXTENT OF BLACK WIRE MESH FENCE
1.22
3Sim
1.23
1Sim
WIND TURBINES; SEE SHEET A1.26
(E) = EXISTING(N) = NEW
1.37
1Sim
(N) BLACK WIRE MESH FENCE(N) EXTENT OF BLACK
WIRE MESH FENCE(N) BLACK WIRE MESH FENCE
(N) EXTENT OF NEW FENCE
(E) EXTENT OF NEW FENCE
(E) EXISTING FENCE
3402 PICO
APRIL 10, 2017 A1.08
N
SITE PLAN (SCALE: 1" = 40'-0")
UP
DN
DN
DN
DN UP
DN
DN
LOBBY
ATRIUM /COURTYARD
OPEN TOBELOW
21.020
11.020
1.192
1.18
2
1.18
1
1.19 1
(E) MEN'SRESTROOM
(E) WOMEN'SRESTROOM
(E) MEN'SRESTROOM
(E) WOMEN'SRESTROOM
EXIT DOWN TO 34TH STREET
OFFICE SPACE OFFICE SPACE
V.I.F.
4' - 7" 170' - 10 1/2" V.I.F.
V.I.F.
4' - 4 1/2"
V.I.F
.
5' -
6 1/
2"11
2' -
3" V
.I.F.
V.I.F
.
4' -
5 1/
2"
NEW PLANTERS
PLANTERS
34TH STREET
PIC
O B
VLD
BIKE SHARE EXISTING WALLGREEN PAINT
NEW BLACK WIRE MESH FENCE
NORTH ENTRY
EXISTING BALCONY AND GUARDRAIL (NO CHANGE)
RAMP
RAM
P
EXISTING FIREDEPARTMENTCONNECTION
LANDSCAPED AREA
SID
EWAL
K
LANDSCAPED AREA LANDSCAPED AREA
BIKE PARKING
EXISTING (NO CHANGE)
179' - 10" V.I.F.
SIDEWALKEXISTING WALLGREEN PAINT
NEW PERGOLA STRUCTURE
NEW SUNKENCOURTYARD
SEATING AREA
SEATING AREA
RAM
P
CALTRANS LOT EAST ENTRY
LANDSCAPEDAREA
MECH
NEW STAIRS TO GROUND FLOOR
EXISTING STAIRS TO LEVEL 3
(E) ELEVATOR
EXIS
TIN
G (N
O C
HAN
GE)
122'
- 3"
V.I.
F.
NEW GATE NEW GATE
EXISTING GATE
1.016 2
REMOVE PORTION OF EXISTING STAIR OPENING
EXISTING MAINTENANCE DOOR
NEW MAINTENANCE DOOR, TYPICAL(3'-9 x 8'-8)
NEW DOOR
NEW DOOR NEW DOOR
NEW BLACK WIRE MESH FENCE
(N) EXTENT OF BLACK WIRE MESH FENCE
(N) EXTENT OF BLACK WIRE MESH FENCE
(E) EXTENT OF NEW FENCE
(E) LINE OF SIDEWALK
3402 PICO
APRIL 10, 2017 A1.11
N
LEVEL 2 FLOOR PLAN (SCALE: 1/16"=1'-0")
3402 PICO
APRIL 10, 2017 A1.33
EXISTING PERSPECTIVE
PROPOSED PERSPECTIVE (UPDATED)
PROJECT DESCRIPTION
REFER TO SHEET A1.00 OF PACKAGE SUBMITTED ON MARCH 21, 2017
SUPPLEMENTAL SHEET INDEXCORNER VIEWS
PROJECT INFORMATION
1.08 ARB - SITE PLAN
1.11 ARB - SECOND FLOOR PLAN
1.32 ARB - COVER PAGE
1.33 ARB - PROJECT INFO
1.34 ARB - RENDERING - CORNER (UPDATED)
1.35 ARB - RENDERING - 34TH ST (UPDATED)
1.36 ARB - SOLAR CANOPIES
1.37 ARB - WIND TURBINES
1.38 ARB - ATRIUM PLANTERS
1.39 ARB - SUNKEN COURTYARD
3402 PICO
APRIL 10, 2017 A1.34PICO AND 34TH ST VIEW - UPDATED RENDER
3402 PICO
APRIL 10, 2017 A1.3534TH STREET VIEW
3402 PICO
APRIL 10, 2017 A1.36
SOLAR CANOPY STRUCTURESVIEW LOOKING NORTHEAST
SOLAR CANOPIES
SOLAR CANOPIES AND WIND TURBINESELEVATION 1/16" = 1'-0"
30' -
0"
25' -
11"
5' -
3"
4' - 7 3/16"
PROPERTY LINE
1.033
2
WIND TURBINE LOCATION (1 OF 3)
FREE
WAY
ABO
VE
1.37
A
1.37
B
1.37
C
DRIVEWAY
DRIVEWAYDRIVEWAY
SUN CAR SHADES; TYP
LANDSCAPING TREES
LANDSCAPING TREES
LANDSCAPING TREES
3402 PICO
APRIL 10, 2017 A1.37WIND TURBINE DETAILS
AXIS: VERTICALHEIGHT: 5.3 FT (1.60 M)WIDTH: 4.6 FT (1.40 M)SWEPT AREA: 22.6 FT2 (2.1 M2)BLADE MATERIALS: CARBON FIBRE AND FIBERGLASS
RATED POWER: 600 WCUT-IN WIND SPEED: 7 MPH (3.5 M/S)RATED RPM: 200 RPMSURVIVAL WIND SPEED: 110 MPH (50 M/S)RATED WIND SPEED: 26 MPH (12 M/S)ANNUAL ENERGY AT 5 M/S: 950 KWHNOISE FROM IEC 61400-11 AT 12M/S: 36 DB
GENERATOR TYPE: 3-PHASE PERMANENT MAGNETDRIVE SYSTEM: DIRECT DRIVERATED OUTPUT
OFF-GRID: 24 VDCGRID-TIE: 600 VDC
INVERTERS AND CONTROLLERS: AVAILABLE FOR ALL LOCATIONS AND REGULATIONS
WIND TURBINE SPECIFICATIONSURBAN GREEN ENERGY - EDDY
WIND TURBINE - PROPOSED PLAN - WIND TURBINES 3/32"-1'-0"
ENLARGED PLAN - WIND TURBINE A ENLARGED PLAN - WIND TURBINE B ENLARGED PLAN - WIND TURBINE C
N
3402 PICO
APRIL 10, 2017A1.38
ATRIUM PLANTERS
3402 PICO
APRIL 10, 2017A1.39
SUNKEN COURTYARD
SUNKEN COURTYARD REFERENCE IMAGE 2SUNKEN COURTYARD REFERENCE IMAGE 1
SUNKEN COURTYARD PLAN
SECTION B DETAIL
SCALE: 1/16"=1'-0"
SECTION A DETAIL
SCALE: 1/16"=1'-0"