15-1 Specialty Windows A R C H I T E C T U R A L D E T A I L F I L E REV.03/08 Contents Architectural Specialty Windows Basic Unit Details AKR Style Aluminum Clad Fixed Units to Complement 400 Series Woodwright®, Tilt-Wash & Gliding Windows 200 Series Tilt-Wash & Gliding Windows All 400 & 200 Series Patio Doors ....................................... 15-2 AKT Style Aluminum Clad Fixed Units to Complement 400 & 200 Series Casement & Awning Windows ............... 15-10 AKW Style Aluminum Clad Fixed Units to Complement 200 Series Tilt-Wash Windows with 3-1/4” Jamb ............... 15-12 AKE Style Aluminum Clad Fixed Units to Complement 200 Series Tilt-Wash Windows with Drywall Return ............ 15-14 AKG Style Aluminum Clad Fixed Units to Complement 200 Series Gliding Windows with Drywall Return ............... 15-15 AKS Style Aluminum Clad Fixed Units to Complement 200 Series Narroline® Double-Hung Windows ................... 15-16 Options / Accessories Andersen Grilles .............................................................. 15-18 Plinth Blocks ................................................................... 15-20 Interior Casing ................................................................. 15-21 Brickmould and Jamb Clips ............................................. 15-24 Suggested Product Applications ............................................. 15-25 Factory-applied 5-1/4”, 6-9/16”, 7-1/8” and custom width extension jambs Andersen divided light, removable interior grilles and contoured Finelight grilles- between-the-glass Curved interior casings Curved exterior aluminum and wood casings in matching radii and a variety of profiles

Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-1

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

Contents

Architectural Specialty Windows

Basic unit Details

AKR Style Aluminum Clad Fixed Units to complement

400 Series Woodwright®, tilt-Wash & Gliding Windows

200 Series tilt-Wash & Gliding Windows

All 400 & 200 Series Patio Doors ....................................... 15-2

AKT Style Aluminum Clad Fixed Units to complement

400 & 200 Series casement & Awning Windows ...............15-10

AKW Style Aluminum Clad Fixed Units to complement

200 Series tilt-Wash Windows with 3-1/4” Jamb ...............15-12

AKE Style Aluminum Clad Fixed Units to complement

200 Series tilt-Wash Windows with Drywall return ............15-14

AKG Style Aluminum Clad Fixed Units to complement

200 Series Gliding Windows with Drywall return ...............15-15

AKS Style Aluminum Clad Fixed Units to complement

200 Series Narroline® Double-hung Windows ...................15-16

Options / Accessories

Andersen Grilles ..............................................................15-18

Plinth Blocks ...................................................................15-20

interior casing .................................................................15-21

Brickmould and Jamb clips .............................................15-24

Suggested Product Applications .............................................15-25

• Factory-applied 5-1/4”, 6-9/16”, 7-1/8” and custom width extension jambs

• Andersen™ divided light, removable interior grilles and contoured Finelight™ grilles-between-the-glass

• curved interior casings

• curved exterior aluminum and wood casings in matching radii and a variety of profiles

Page 2: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-2

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

Basic Unit Details

AKR Style Aluminum Clad Fixed Window DetailsScale 3" = 1'-0" (1:4)

1-1/2"(38) 11/16" (18)

13/16" (21)

11/16" (18)

11/16" (18)

13/16" (21)

13/16" (21)

4-1/2" (114) Jamb Widthand Wall thickness

4-1/2" (114) Jamb Width

4-1/2" (114) Jamb Width 4-1/2" (114) Jamb Width

5-13/16" Front to Back (148)

1-5/16"(33)

1-5/16"(33)

1-5/16"(33)

1-5/16"(33)

Min

imum

rou

gh O

peni

ng h

eigh

t

unit

Dim

ensi

on h

eigh

t

unob

stru

cted

Gla

ss h

eigh

t 1

1/2

"(3

8) 1

1/2

"(3

8)

Optional interiortrim stop

Optional arch casing

high-Performance™ low-einsulating glass

Lineal Head

SillSill

Curved Head Curved Head

Sill

Curved Head

Vertical Sections

Sill

Curved Head

5-3/16" (132) Wall thickness

6-1/2" (165) Front to Back

3/4"(19)

6-1/2" (165) Wall thickness

7-13/16" (198) Front to Back

2" (51)

7-1/8" (181) Wall thickness

8-7/16" (214) Front to Back

2-5/8" (67)

To Complement: 400 Series Woodwright® and Tilt-Wash Double-Hung Windows 200 Series Gliding Window

Page 3: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-3

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

Basic Unit Details

AKR Style Aluminum Clad Fixed Window DetailsScale 3" = 1'-0" (1:4)

To Complement: All 400 & 200 Series Patio Doors 400 Series Gliding Window 200 Series Tilt-wash Double-Hung Window

1-1/2"(38) 11/16" (18)

13/16" (21)

11/16" (18)

11/16" (18)

13/16" (21)

13/16" (21)

4-9/16" (116) Jamb Widthand Wall thickness

4-9/16" (116) Jamb Width

4-9/16" (116) Jamb Width 4-9/16" (116) Jamb Width

5-7/8" Front to Back (148)

1-5/16"(33)

1-5/16"(33)

1-5/16"(33)

1-5/16"(33)

Min

imum

rou

gh O

peni

ng h

eigh

t

unit

Dim

ensi

on h

eigh

t

unob

stru

cted

Gla

ss h

eigh

t 1

1/2

"(3

8) 1

1/2

"(3

8)

Optional interiortrim stop

Optional arch casing

high-Performance™ low-einsulating glass

Lineal Head

SillSill

Curved Head Curved Head

Sill

Curved Head

Vertical Sections

Sill

Curved Head

5-1/4" (133) Wall thickness

6-9/16" (167) Front to Back

11/16"(17)

6-9/16" (167) Wall thickness

7-7/8" (200) Front to Back

2" (51)

7-1/8" (181) Wall thickness

8-7/16" (214) Front to Back

2-9/16" (65)

See joining section for optional exterior extension jambs.

Page 4: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-4

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

high-Performance™ low-einsulating glass

Jamb

JambJamb

Jamb

JambJamb

Minimum rough Opening Width

unit Dimension Width

unobstructed Glass Width 1 1/2"(38)

1 1/2"(38)

Minimum rough Opening Width

unit Dimension Width

unobstructed Glass Width 1 1/2"(38)

1 1/2"(38)

4-1

/2"

(114

) Jam

b W

idth

1-5/16"(33)

1-5/16"(33)

11/16"(18)

13/16"(21)

4-9

/16"

(116

) Jam

b W

idth

Single Glazed Option Decorative triple Glazed Option

Horizontal Section

Horizontal Section

Horizontal Section

Basic Unit Details

AKR Style Aluminum Clad Fixed Window DetailsScale 3" = 1'-0" (1:4)

To Complement: 400 Series Woodwright® and Tilt-Wash Double-Hung Windows 200 Series Gliding Window

To Complement: All 400 & 200 Series Patio Doors 400 Series Gliding Window 200 Series Tilt-wash Double-Hung Window

Page 5: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-5

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

Joining Details

AKR Style Aluminum Clad Fixed Window Joined to 400 Series Woodwright® & Tilt-Wash Double-Hung WindowScale 3" = 1'-0" (1:4)

Head

Jamb

Jamb

Mullion

MullionTransom

AKR Style Aluminum Clad Fixed Window Joined to 200 Series Tilt-Wash Double-Hung Window for 4-1/2" WallScale 3" = 1'-0" (1:4)

Head

Mullion

Jamb

Jamb

Transom Mullion

Joining Compatibility Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. combination designs should always be checked for design pressure performance requirements to make sure the appropriate joining method is specified.

Page 6: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-6

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

Head

Transom

Mullion

Mullion

Jamb

Jamb

Joining Details

AKR Style Aluminum Clad Fixed Window Joined to 200 Series Gliding Window for 4-1/2” WallScale 3" = 1'-0" (1:4)

AKR Style Aluminum Clad Fixed Window Joined to 400 Series Gliding WindowScale 3" = 1'-0" (1:4)

Head

Transom

Mullion

Mullion

Jamb

Jamb

Joining Compatibility Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. combination designs should always be checked for design pressure performance requirements to make sure the appropriate joining method is specified.

Page 7: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-7

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

Joining Details

AKR Style Aluminum Clad Fixed Window Joined to 400 Series Frenchwood® Gliding Patio DoorScale 3" = 1'-0" (1:4)

AKR Style Aluminum Clad Fixed Window Joined to 400 Series Frenchwood® Hinged Patio Door - InswingScale 3" = 1'-0" (1:4)

Head

Jamb

Jamb

Mullion

MullionTransom

Head

Jamb

Jamb

Mullion

MullionTransom

Joining Compatibility Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. combination designs should always be checked for design pressure performance requirements to make sure the appropriate joining method is specified.

Page 8: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-8

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

AKR Style Aluminum Clad Fixed Window Joined to 200 Series Narroline® Gliding Patio DoorScale 3" = 1'-0" (1:4)

AKR Style Aluminum Clad Fixed Window Joined to 400 Series Frenchwood® Hinged Patio Door - OutswingScale 3" = 1'-0" (1:4)

Joining Details

Head

Jamb

Jamb

Mullion

MullionTransom

Head

Transom

Jamb

Jamb

Mullion

Mullion

Joining Compatibility Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. combination designs should always be checked for design pressure performance requirements to make sure the appropriate joining method is specified.

Page 9: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-9

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

AKR Style Aluminum Clad Fixed Window Joined to 200 Series Perma-Shield® Gliding Patio DoorScale 3" = 1'-0" (1:4)

AKR Style Aluminum Clad Fixed Window Joined to 200 Series Hinged Patio Door - InswingScale 3" = 1'-0" (1:4)

Joining Details

Mullion

Mullion

Jamb

Jamb

Head

Transom

Head

Transom Mullion

Jamb Mullion

Jamb

Joining Compatibility Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. combination designs should always be checked for design pressure performance requirements to make sure the appropriate joining method is specified.

Page 10: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-10

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

Basic Unit Details

AKT Style Aluminum Clad Fixed Window DetailsScale 3" = 1'-0" (1:4)

5-1/4" (133)Wall thickness

6-9/16" (167) Front to Back

2-3/8" (60)2-7/8" (73)

4-9/16" (116)Wall thickness

5-7/8" (149) Front to Back

1-5/16"(33)

1-5/16"(33)

1-5/16"(33)

1-11/16"(43)

2-7/8" (73)

1-5/16"(33)

1-5/16"(33)

2-7/8" (73) 2-7/8" (73)

6-9/16" (167) Wall thickness

7-7/8" (200) Front to Back

3-11/16" (94)

7-1/8" (181) Wall thickness

8-7/16" (214) Front to Back

4-1/4" (108)

1-13/16"(46)

1-1

3/16

"(4

6) 1

-13/

16"

(46)

11/16" (18)

1-1/8" (29)

11/16" (18)

1-1/8" (29)

11/16" (18)

1-1/8" (29)

Min

imum

rou

gh O

peni

ng h

eigh

t

unit

Dim

ensi

on h

eigh

t

unob

stru

cted

Gla

ss h

eigh

t

Optional extension jamb

Optional arch casing

2-7/8"Wall thickness

4-3/16" (106)Front to Back

Lineal Head

Sill Sill

Curved HeadCurved Head

Sill

Curved Head

Sill

Curved Head

Sill

Curved Head

Vertical Sections

To Complement: 400 and 200 Series Casement and Awning Windows

Page 11: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-11

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

Basic Unit Details

AKT Style Aluminum Clad Fixed Window DetailsScale 3" = 1'-0" (1:4)

AKT Style Aluminum Clad Fixed Window Joined to 400 & 200 Series Casement and Awning WindowsScale 3" = 1'-0" (1:4)

11/16" (18) 1-1/8" (29)

4-9

/16"

(116

) Jam

b W

idth

1-5/16" (33)

1 13/16"(46)

1 13/16"(46)

Minimum rough Opening Width

unit Dimension Width

high-Performance™ low-einsulating glass

Jamb

Jamb

Single Glazed Option

Decorative triple Glazed Option

Horizontal Section

Jamb Jamb

Horizontal Section

To Complement: 400 and 200 Series Casement and Awning Windows

Mullion

MullionTransom

Head

Jamb

Jamb

Joining Compatibility Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. combination designs should always be checked for design pressure performance requirements to make sure the appropriate joining method is specified.

Page 12: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-12

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

Basic Unit Details

AKW Style Aluminum Clad Fixed Window DetailsScale 3" = 1'-0" (1:4)

To Complement: 200 Series Tilt-Wash Double-Hung Window with 3-1/4" Jamb

4-1/2" Front to Back

3-3/16"(81)

3-3/16" (81)Wall Thickness

5-1/4" (133)Wall Thickness

6-9/16" (167) Front to Back

2-1/16"(52)

6-9/16" (167)Wall Thickness

3-5/16"(84)

3-3/16"(81)

7-1/8" (181)Wall Thickness

8-7/16" (214) Front to Back

3-15/16"(100)

4-1/2" (114) Jamb Widthand Wall Thickness

5-13/16" (148) Front to Back

1-5/16"(33)

1-5/16"(33)

3-3/16"(81)

1-5/16"(33)

1-5/16"(33)

1-5/16"(33)

3-3/16"(81)

1-5/16"(33)

7-13/16" (198) Front to Back

1-1/2"(38)

11/16" (18)

13/16" (21)

11/16" (18)

11/16" (18)

13/16" (21)

13/16" (21)

Min

imum

Rou

gh O

peni

ng H

eigh

t

Unit

Dim

ensi

on H

eigh

t

Unob

stru

cted

Gla

ss H

eigh

t 1

1/2

"(3

8) 1

1/2

"(3

8)

Optional interiortrim stop

Optional arch casing

High-Performance™ Low-Einsulating glass

Lineal Head

Sill

Vertical Sections

Curved Head

Sill

Curved Head

Sill

Curved Head

Curved Head Curved Head

Page 13: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-13

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

Basic Unit Details

AKW Style Aluminum Clad Fixed Window DetailsScale 3" = 1'-0" (1:4)

To Complement: 200 Series Tilt-Wash Double-Hung Windows with 3-1/4" Jamb

4-1/

2" F

ront

to B

ack

3-3/

16"

(81)

Wal

l Thi

ckne

ss1-

5/16

"(3

3)

Minimum Rough Opening Width

Unit Dimension Width

Unobstructed Glass Width 1 1/2"(38)

1 1/2"(38)

High-Performance™ Low-Einsulating glass

Horizontal Sections

Jamb Jamb

Head

Jamb

Jamb

Mullion

Transom Mullion

AKW Style Aluminum Clad Fixed Window joined to 200 Series Tilt-Wash Double-Hung Window with 3-1/4” Jamb Scale 3" = 1'-0" (1:4)

Joining Compatibility Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. combination designs should always be checked for design pressure performance requirements to make sure the appropriate joining method is specified.

Page 14: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-14

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

3-1/16" (78)Wall Thickness

Head

Jamb

Jamb

Jamb Jamb

Curved Head

Sill

Mullion

MullionTransom

4-3/8" (111) Front to Back

Min

imum

Rou

gh O

peni

ng H

eigh

t

Unit

Dim

ensi

on H

eigh

t

Unob

stru

cted

Gla

ss H

eigh

t 1

1/2

"(3

8) 1

1/2

"(3

8)

4-3/

8" (1

11) F

ront

to B

ack

3-1/

16"

(78)

Wal

l Thi

ckne

ss1-

5/16

"(3

3)

1-5/16"(33)

Minimum Rough Opening Width

Unit Dimension Width

Unobstructed Glass Width 1 1/2"(38)

1 1/2"(38)

High-Performance™ Low-Einsulating glass

Vertical Sections Horizontal Sections

Basic Unit Details

Joining Details Scale 3" = 1'-0" (1:4)

AKE Style Aluminum Clad Fixed Window DetailsScale 3" = 1'-0" (1:4)

To Complement: 200 Series Tilt-Wash Double-Hung Window with Drywall Return

Joining Compatibility Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. combination designs should always be checked for design pressure performance requirements to make sure the appropriate joining method is specified.

Page 15: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-15

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

Joining Compatibility Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. combination designs should always be checked for design pressure performance requirements to make sure the appropriate joining method is specified.

Basic Unit Details

AKG Style Aluminum Clad Fixed Window DetailsScale 3" = 1'-0" (1:4)

Nailing Fin is includedonly to position the window

at the specified wall thickness.Window to be anchored using

supplied installation clips.

2-3/4" (70)Wall Thickness

4-1/16" (103)Front to Back

1-5/16"(33)

2-3/

4" (7

0)W

all T

hick

ness

4-1/

16"

(103

)Fr

ont t

o Ba

ck

1-5/

16"

(33)

Min

imum

Rou

gh O

peni

ng H

eigh

t

Unit

Dim

ensi

on H

eigh

t

Unob

stru

cted

Gla

ss H

eigh

t 1

1/2

"(3

8) 1

1/2

"(3

8)

JambJamb

Minimum Rough Opening Width

Unit Dimension Width

Unobstructed Glass Width 1 1/2"(38)

1 1/2"(38)

High-Performance™ Low-Einsulating glass

Horizontal Sections

Head Jamb

Jamb

Mullion

Mullion

Transom

Sill

Vertical Sections

Curved Head

To Complement: 200 Series Gliding Window with Drywall Return

Joining Details Scale 3" = 1'-0" (1:4)

Page 16: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-16

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

Basic Unit Details

AKS Style Aluminum Clad Fixed Window DetailsScale 3" = 1'-0" (1:4)

To Complement: 200 Series Narroline® Double-Hung Window

1-1/2"(38) 11/16" (18)

13/16" (21)

11/16" (18)

11/16" (18)

13/16" (21)

13/16" (21)

4-1/2" (114) Jamb Widthand Wall thickness

4-1/2" (114) Jamb Width

4-1/2" (114) Jamb Width 4-1/2" (114) Jamb Width

5-13/16" Front to Back (148)

1-5/16"(33)

1-5/16"(33)

1-5/16"(33)

1-5/16"(33)

Min

imum

rou

gh O

peni

ng h

eigh

t

unit

Dim

ensi

on h

eigh

t

unob

stru

cted

Gla

ss h

eigh

t 1

1/2

"(3

8) 1

1/2

"(3

8)

Optional interiortrim stop

Optional arch casing

high-Performance™ low-einsulating glass

Lineal Head

SillSill

Curved Head Curved Head

Sill

Curved Head

Vertical Sections

Sill

Curved Head

5-3/16" (132) Wall thickness

6-1/2" (165) Front to Back

3/4"(19)

6-1/2" (165) Wall thickness

7-13/16" (198) Front to Back

2" (51)

7-1/8" (181) Wall thickness

8-7/16" (214) Front to Back

2-5/8" (67)

Page 17: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-17

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

Basic Unit Details

AKS Style Aluminum Clad Fixed Window DetailsScale 3" = 1'-0" (1:4)

To Complement: 200 Series Narroline® Double-Hung Window

high-Performance™ low-einsulating glass

JambJamb

Minimum rough Opening Width

unit Dimension Width

unobstructed Glass Width 1 1/2"(38)

1 1/2"(38)

4-1

/2"

(114

) Jam

b W

idth

1-5/16"(33)

11/16"(18)

13/16"(21)

Horizontal Section

Transom Mullion

Mullion

Head

Jamb

Jamb

AKS Style Aluminum Clad Fixed Window Joined to 200 Series Narroline® Double-Hung WindowScale 3" = 1'-0" (1:4)

Joining Compatibility Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. combination designs should always be checked for design pressure performance requirements to make sure the appropriate joining method is specified.

Page 18: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-18

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

Options / Accessories

400 Series Grille Options

Permanent Exterior Permanent Interiorwith Spacer

Full divided light features permanently applied interior and exterior grilles with spacers between the glass. Interior grilles are available in unfinished pine, maple, oak or prefinished white. Exterior grilles are patented Fibrex® material.

Simulated divided light offers grilles on the interior and exterior with no spacers between the glass. Interior grilles can be specified as permanent or removable. Interior grilles are available in unfinished pine, maple, oak or prefinished white. Exterior grilles are patented Fibrex® material.

Andersen® Finelight™ grilles are suspended between the glass panes and, in most cases, feature a contoured 3/4" profile. A 1" profile is used on patio doors, Springline™ windows and many arch windows. Finelight™ grilles are installed during manufacture and must be ordered with the unit. Removable interior grilles snap off for easy cleaning.

* Tinted glass may affect the appearance of Finelight grille color.

Configurations All grille configurations can be ordered with interior and exteriors to match window and patio door interiors and exteriors.

Full Divided Light Simulated Divided Light Easy-Clean Options

Permanent ExteriorPermanent Interior

Permanent ExteriorRemovable Interior

RemovableInterior

Finelight™ Grilles-Between-the-Glass*

Page 19: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-19

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

Options / Accessories

Grille ProfilesScale = Full - dimensions include thickness of tape

3/32"

5/16"

5/16" 7/16"

7/16"

45˚

2-1/4"

53˚3/8"3/8"3/8" 53˚

7/8"

45˚45˚

3/4"

53˚ 35˚

1-1/8"

35˚

1/2"

1-13/16"

5/16" 7/16"

2-1/4"7/8"3/4" 1-1/8"

1/2"

7/8"3/4" 1-1/8"

1/2" 1-13/16"

5/16"5/16"5/16"

Permanent Exterior Fibrex® Material Grille Profiles (chamfer profile). Also used for pre-finished interior, except 400 Series Woodwright® double-hung windows.

Permanent Interior Wood Grille Profiles (chamfer profile).the Fibrex® material exterior grille is used when a permanent prefinished grille is specified, except with 400 Series Woodwright® double-hung windows.

Removable Interior Wood Grille Profile (roman ogee profile). Removable Interior Wood Grille Profile (chamfer profile).400 Series Woodwright® double-hung windows only.

Permanent Full Divided Light Grille spacer location.

Andersen® Finelight™ Grilles-Between-the-Glass.

7/16"

7/8"3/4" 1-1/8"

3/8"

3/4"

1/2"

1"

1/8" 1/8" 11/16"1/16"

5/8" 5/8" 7/8" 7/8"

Page 20: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-20

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

Trim Options and Applications

Plinth Blocks Available in maple, oak, cherr y, mahogany, and douglas fir.Scale: half

Optional Andersen®

interior arch casing(Colonial or Ranch styles)

Optional Andersen® transom casing

Optional Andersen® plinth blocks

Interior trim by others

For use with 2-1/4" or 2-1/2" casing See more trim option examples on the following pages.

2-7/8" (73)

1-1/8" R

2-7/8" (73)

7/8"(22)

7/8"(22)

For use with 3-1/2" casing

3-7/8" (98) 1-1/2" R

3-7/8" (98)

2-7/8" (73)

7/8"(22)

7/8"(22)

3-7/8" (98)

5-1/4" (133)

4" R

1-1/2" R

4" (102)

3" R

1-1/8" R

Page 21: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-21

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

AKR Curved Window AKT Curved Window

Ranch Style - WM 3152-1/2" x 11/16" (64mm x 17mm)

Available in select hardwoods.

Colonial Style - WM 3512-1/2" x 11/16" (64mm x 17mm)

Available in select hardwoods.

Colonial Style - WM 4443-1/2" x 11/16" (89mm x 17mm)

Available in select hardwoods..

5/32" (4mm) typical

5/32" (4mm) typical

Ranch Style - WM 3242-1/4" x 11/16" (57mm x 17mm)

Available in select hardwoods.

Colonial Style - WM 3662-1/4" x 11/16" (57mm x 17mm)

Available in select hardwoods.

Trim Options and Applications

Interior CasingScale: FullAvailable for all cur ved portions of windows.

Page 22: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-22

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

Interior arch casing

Lineal interior casing by others

Plinth block

Arch interior casing

Arch interior casing

Plinth block

3/16" mull casing

Plinth block by others

Mull casing by others

Plinth block

Mull casing

Lineal interior casing by others

Plinth block by others

Mull casing by others

Arch interior casing

Arch Window Arch Window

Curved Top Window Casement Window

Casement Window

Curved Top Window Casement Window

Arch Window Arch Window

Curved Top Window

Curved Top Window

Trim Options and Applications

Transom Joining of Cur ved Top

Arch Combination

Arch Palladium / Casement Combination

Page 23: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-23

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

Trim Options and Applications

Transom Joining of Partial Chord

Arch interior casing

Plinth block

Lineal interior casing by others

Arch extension jamb

Extension jamb

Angle cut extension jamb. Plinth block or casing will conceal gap.

Arch interior casing

Plinth block

Casement Window

Arch WindowArch Window

Frenchwood® Gliding Patio Door

Arch Window

Arch Window

Andersen® Gliding Patio Door

Frenchwood® Hinged Door - Inswing

Page 24: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-24

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

Options / Accessories

Exterior Brickmould and Jamb Clips Scale 3" = 1'-0" (1:4)

Nailing Fin is includedonly to position the windowat the specified wall thickness.Window to be anchored usingsupplied installation clips.

Vertical DetailAKR7 Frame

1-5/16"(33)

OptionalAluminum Brickmould

1-3/8"(35) 3/4"

(19)

installation clip in shipping position

Page 25: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-25

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

Suggested Product Applications — AKR Style Aluminum Clad Fixed Windows

Wall Types Scale 1-1/2" = 1'-0" (1:8)

Vertical SectionBrick veneer / 2 x 6" Metal Stud Framing

Vertical SectionWood Siding / 2 x 4 Wood Stud Framing

Vertical Sectione.i.F.S. / concrete Masonr y unit (cMu)

Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.

Construction by OthersAndersen corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.

NOte: Where e.i.F.S. wall finish is adjacent to window units, contact e.i.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant

joint around the perimeter of the window.

NOte: leave adequate clearance between sill and masonry for caulking and dimensional change of framework. installation flange may be removed where construction sequence/ detailing requires no flange.

Transom

Min

. Rou

gh O

peni

ng H

eigh

t

Unit

Dim

ensi

on H

eigh

t

Head

Installation flange all around

Optional Andersen® 3/4" x 5-1/2" (19 x 140) vinyl trim board

Installation flange all around

Andersen® Woodwright™ unit

Optional Andersen® arch casing

Unit

Dim

ensi

on H

eigh

t

Min

imum

Rou

gh O

peni

ng H

eigh

t

Head

Transom Optional Andersen®

inside transom casingOptional modifiedAndersen® vinyl trim strip set in sealant

Andersen®

Woodwright™ unit

Installationflange athead

Membrane flashing over installationflange(by others)

Unit

Dim

ensi

on H

eigh

t

Min

imum

Rou

gh O

peni

ng H

eigh

t

Head

Transom Optional Andersen®

inside transom casingOptional modifiedAndersen® vinyl trim strip set in sealant

Andersen®

Woodwright™ unit

Removeinstallationflange all around

Page 26: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-26

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

Suggested Product Applications — AKR Style Aluminum Clad Fixed Windows

Wall Types Scale 1-1/2" = 1'-0" (1:8)

Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.

Construction by OthersAndersen corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.

NOte: Where e.i.F.S. wall finish is adjacent to window units, contact e.i.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant

joint around the perimeter of the window.

NOte: leave adequate clearance between sill and masonry for caulking and dimensional change of framework. installation flange may be removed where construction sequence/ detailing requires no flange.

Vertical SectionBrick / concrete Masonr y unit (cMu)

Vertical SectionStucco / concrete Masonr y unit

(cMu) inset Window

Vertical Sectionexisting Stud Wall

Vertical Sectionexisting Masonr y Wall

Optional Andersen® auxiliary casing

Unit

Dim

ensi

on H

eigh

t

Min

imum

Rou

gh O

peni

ng H

eigh

t

Head

Transom Optional Andersen® inside transom casing

Optional modified Andersen® vinyl trim strip set in sealant

Andersen® Woodwright™ unit

Optional Andersen®

auxiliarycasing

Unit

Dim

ensi

on H

eigh

t

Min

imum

Rou

gh O

peni

ng H

eigh

t

Head

Transom Optional Andersen®

inside transom casing& plinth block

Optional modifiedAndersen® vinyl trim strip set in sealant Andersen® Woodwright™ unit

Optional Andersen®

arch casingOptional Andersen®

vinyl trim board

Existingframe wall

TransomOptionalAndersen® vinyl trim strip set in sealant

Andersen®

Frenchwood®

Hinged Patio Door

Optional Andersen®

inside transom casing & plinth blocks

Roug

h Op

enin

g He

ight

Unit

Dim

ensi

on H

eigh

t Head

Transom Optional Andersen® inside transom casing & plinth blocks

OptionalAndersen® vinyl trim strip

Andersen® Frenchwood® Patio Door

Existing masonry wall

Optional Andersen® vinyl trim board. Trim to fit as required. Finish trimmed edge with Optional Andersen®

rigid vinyl channel

Min

imum

Rou

gh O

peni

ng H

eigh

t

Unit

Dim

ensi

on H

eigh

t Head

Optional Andersen® arched extension jamb trimmed to fit

Page 27: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-27

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l er e v . 0 3 / 0 8

Suggested Product Applications — AKT Style Aluminum Clad Fixed Windows

Vertical SectionBrick veneer / 2 x 6" Metal Stud Framing

Vertical SectionWood Siding / 2 x 4 Wood Stud Framing

Vertical Sectione.i.F.S. / concrete Masonr y unit (cMu)

Wall Types Scale 1-1/2" = 1'-0" (1:8)

Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.

Construction by OthersAndersen corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.

NOte: Where e.i.F.S. wall finish is adjacent to window units, contact e.i.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant

joint around the perimeter of the window.

NOte: leave adequate clearance between sill and masonry for caulking and dimensional change of framework. installation flange may be removed where construction sequence/ detailing requires no flange.

Min

. Rou

gh O

peni

ng H

eigh

t

Unit

Dim

ensi

on H

eigh

t

Head

Installation flange all around

Optional Andersen®

extensionjambs

Optional Andersen®

3/4" x 5-1/2"(19 x 140)vinyl trimboard

Installationflangeall around

Andersen®

casement unit

Head

Transom

Unit

Dim

ensi

on H

eigh

t

Min

imum

Rou

gh O

peni

ng H

eigh

t

Remove installation flange at head

Optional Andersen®

inside transom casingOptional Andersen® vinyl trim strip set in sealant and wood filler

Andersen®

casement unit

Unit

Dim

ensi

on H

eigh

t

Min

imum

Rou

gh O

peni

ng H

eigh

t

Head

Transom Optional Andersen®

inside transom casingOptional Andersen® vinyl trim strip set in sealant and wood filler

Andersen®

casement unit

Installationflange athead

Membrane flashing over installationflange(by others)

Page 28: Architectural Specialty Windows - Architectural Detail File/media/aw/files/... · 2014. 7. 15. · 15-3 Specialty Windows rev.03/08 ArchitecturAl DetAil File Basic Unit Details AKR

15-28

S p e c i a l t y W i n d o w s

A r c h i t e c t u r A l D e t A i l F i l e r e v . 0 3 / 0 8

Suggested Product Applications — AKT Style Aluminum Clad Fixed Windows

Vertical SectionBrick / concrete Masonr y unit (cMu)

Vertical SectionStucco / concrete Masonr y unit

(cMu) inset Window

Vertical Sectionexisting Stud Wall

Vertical Sectionexisting Masonr y Wall

Wall Types Scale 1-1/2" = 1'-0" (1:8)

Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.

Construction by OthersAndersen corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.

NOte: Where e.i.F.S. wall finish is adjacent to window units, contact e.i.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper

width of sealant joint around the perimeter of the window.

NOte: leave adequate clearance between sill and masonry for caulking and dimensional change of framework. installation flange may be removed where construction sequence/ detailing requires no flange.

Unit

Dim

ensi

on H

eigh

t

Min

imum

Rou

gh O

peni

ng H

eigh

t

Optional Andersen® auxiliary casing

Head

Transom Optional Andersen® inside transom casing

Optional Andersen® vinyl trim strip set in sealant and wood filler

Andersen® casement unit

Optional Andersen®

auxiliarycasing

Installation flange at head

Unit

Dim

ensi

on H

eigh

t

Min

imum

Rou

gh O

peni

ng H

eigh

t

Optional Andersen®

plinth blocks

Head

Transom Optional Andersen®

inside transom casing

Optional Andersen®

extension jambs

Optional Andersen® vinyl trim strip set in sealant and wood filler

Andersen®

casement unit

Optional Andersen®

vinyl trim board

Existingframe wall

Transom Optional Andersen®

inside transom casingOptional Andersen® vinyl trim strip set in sealant and wood filler

Andersen®

casement unit

Optional Andersen®

plinth blocks

Min

imum

Rou

gh O

peni

ng H

eigh

t

Unit

Dim

ensi

on H

eigh

t

Head

Optional Andersen®

extensionjambs

Transom Optional Andersen® inside transom casing & plinth blocks

Optional Andersen® vinyl trim strip set in sealant and wood filler

Andersen®casement unit

Existing masonry wall

Optional Andersen® vinyl trim board. Trim to fit as required. Finish trimmed edge with Optional Andersen®

rigid vinyl channel

Min

imum

Rou

gh O

peni

ng H

eigh

t

Unit

Dim

ensi

on H

eigh

t

Head

Optional Andersen® extension jamb