MEMBERS: A.S.F.E. American Concrete Institute American Society for Testing and Materials Florida Institute of Consulting Engineers SUBSURFACE SOIL EXPLORATION PROPOSED DIRECTIONAL DRILL UNDER S.R. 80, EAST OF BIRCHWOOD PARKWAY FOR WATER MAIN RELOCATION PORT LABELLE, HENDRY COUNTY, FLORIDA Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants OFFICES Orlando, 8008 S. Orange Avenue, Orlando, Florida 32809, Phone (407) 855-3860 Bartow, 1525 Centennial Drive, Bartow, Florida 33830, Phone (863) 533-0858 Cocoa, 1300 N. Cocoa Blvd., Cocoa, Florida 32922, Phone (321) 632-2503 Fort Myers, 9970 Bavaria Road, Fort Myers, Florida 33913, Phone (239) 768-6600 Miami, 2608 W. 84 th Street, Hialeah, Florida 33016, Phone (305) 825-2683 Port St. Lucie, 460 Concourse Place NW, Unit 1, Port St. Lucie, Florida 34986, Phone (772) 878-0072 Sarasota, 78 Sarasota Center Blvd., Sarasota, Florida, Phone (941) 922-3526 Tallahassee, 3175 West Tharpe Street, Tallahassee, Florida 32303, Phone (850) 576-6131 Tampa, 3925 Coconut Palm Drive, Suite 115, Tampa, Florida 33619, Phone (813) 620-3389 West Palm Beach, 2200 N. FL Mango Rd., Ste. 101, West Palm Bch., FL 33409, Phone (561)687-8200

Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately

Embed Size (px)

Citation preview

Page 1: Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately

MEMBERS:A.S.F.E.

American Concrete InstituteAmerican Society for Testing and Materials

Florida Institute of Consulting Engineers

SUBSURFACE SOIL EXPLORATIONPROPOSED DIRECTIONAL DRILL

UNDER S.R. 80, EAST OF BIRCHWOOD PARKWAYFOR WATER MAIN RELOCATION

PORT LABELLE, HENDRY COUNTY, FLORIDA

Ardaman & Associates, Inc.Geotechnical, Environmental andMaterials Consultants

OFFICES

Orlando, 8008 S. Orange Avenue, Orlando, Florida 32809, Phone (407) 855-3860Bartow, 1525 Centennial Drive, Bartow, Florida 33830, Phone (863) 533-0858

Cocoa, 1300 N. Cocoa Blvd., Cocoa, Florida 32922, Phone (321) 632-2503Fort Myers, 9970 Bavaria Road, Fort Myers, Florida 33913, Phone (239) 768-6600

Miami, 2608 W. 84th Street, Hialeah, Florida 33016, Phone (305) 825-2683Port St. Lucie, 460 Concourse Place NW, Unit 1, Port St. Lucie, Florida 34986, Phone (772) 878-0072

Sarasota, 78 Sarasota Center Blvd., Sarasota, Florida, Phone (941) 922-3526Tallahassee, 3175 West Tharpe Street, Tallahassee, Florida 32303, Phone (850) 576-6131Tampa, 3925 Coconut Palm Drive, Suite 115, Tampa, Florida 33619, Phone (813) 620-3389

West Palm Beach, 2200 N. FL Mango Rd., Ste. 101, West Palm Bch., FL 33409, Phone (561)687-8200

Page 2: Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately

Ardaman & Associates, Inc.

Geotechnical, Environmental andMaterials Consultants

9970 Bavaria Road, Fort Myers, Florida 33913 Phone (239) 768-6600 FAX (239) 768-0409Florida: Bartow, Fort Myers, Miami, Orlando, Port St. Lucie, Sarasota, Tallahassee, Tampa, West Palm Beach

Louisiana: Alexandria, Baton Rouge, Monroe, New Orleans, Shreveport

Ardaman Project No. 14-33-451213-MAR-2014

Tetra Tech10600 Chevrolet Way, Suite 300Estero, FL 33928

Attention: Mr. Danny M. Nelson, P.E.

SUBJECT: Subsurface Soil ExplorationProposed Directional DrillUnder S.R. 80, East of Birchwood Parkwayfor Water Main RelocationPort LaBelle, Hendry County, Florida

Gentlemen:

As requested and authorized by Tetra Tech (Tt), Ardaman & Associates, Inc. (Ardaman) has completed the

subsurface soil exploration program for the subject project. The purposes of this program were to evaluate

the general subsurface conditions for the proposed directional drill under S.R. 80 east of Birchwood Parkway

in Port LaBelle, Hendry County, Florida for a water main relocation.

This report documents our findings and conclusions. It has been prepared for the exclusive use of

Tt and their consultants for specific application to the subject project in accordance with generally accepted

geotechnical engineering practices. No other warranty, expressed or implied, is made.

SCOPE OF GEOTECHNICAL SERVICES

The scope of our services was limited to the following items:

1. Conducting one Standard Penetration Test (SPT) boring to determine the nature and condition ofthe subsurface soils to a depth of 20 feet.

2. Reviewing each soil sample obtained in our field testing program by a geotechnical engineer in ourlaboratory for further identification and assignment of laboratory tests, if necessary.

Page 3: Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately

Report of Subsurface Soil Exploration 13-MAR-2014Proposed Directional Drill Project No.14-33-4512Under S.R. 80, East of Birchwood Parkway Page No. 2Port LaBelle, Hendry County, Florida

Ardaman & Associates, Inc.

3. Performing the appropriate laboratory tests on selected samples, if necessary.

4. Preparing this report to document the results of our field exploration and laboratory testingprograms.

SITE LOCATION

Hendry County plans to relocate a 12-inch water main due to the widening of S.R. 80. The new water main

will be installed under S.R. 80 by directional drilling. The location of the water main is approximately 0.7

miles east of the Birchwood Parkway intersection with S.R. 80 in Port LaBelle, Hendry County, Florida,

near STA 1688+45. The test boring was performed in the north right-of-way of S.R. 80.

FIELD EXPLORATION PROGRAM

Our field exploration consisted of performing one SPT boring. The SPT boring was drilled to a depth of 20

feet below the existing ground surface. The SPT boring was conducted using methods consistent with ASTM

D-1586. The equipment and procedures used in the SPT boring are described in detail in the Appendix.

The boring was located in the field based upon a State Plane coordinate in NAD 83 FL East provided by Tt.

The State Plane coordinate was converted to GPS coordinates as shown on the attached boring log with

adjustments for existing underground utilities.

GENERAL SUBSURFACE CONDITIONS

The general subsurface conditions encountered during the field exploration are shown on the attached soil

boring log. Soil stratification is based on examination of recovered soil samples and interpretation of the field

boring log. The stratification lines represent the approximate boundaries between the soil types, the actual

transitions may be gradual.

Page 4: Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately

Report of Subsurface Soil Exploration 13-MAR-2014Proposed Directional Drill Project No.14-33-4512Under S.R. 80, East of Birchwood Parkway Page No. 3Port LaBelle, Hendry County, Florida

Ardaman & Associates, Inc.

A generalization of subsurface soil conditions encountered in the boring is described below.

DepthFrom To Soil Description

Ground Surface 8 ' Loose to medium dense fine sands (SP).

8' 8.5' Medium dense clayey fine sand (SC).

8.5' 13' Medium dense calcareous silty fine sand with some gravel-size limerockfragments. This stratum may also be described as Soft Limestone.

13' 15.5' Hard Limestone.

15.5' 20' (TERM) Loose to medium dense calcareous slightly silty medium to fine sand,trace to some gravel-size shell fragments and cemented sands.

Groundwater was encountered in the borehole at 7.5 feet below the existing ground surface at the time of our

field exploration (06-MAR-2014). The groundwater depth shown on the boring log represents the

groundwater surface encountered on the date shown. Fluctuations in groundwater level should be anticipated

throughout the year due to seasonal variations in rainfall, and other factors.

LABORATORY TESTING PROGRAM

Representative soil samples obtained during our field sampling operation were packaged and transferred to

our office and, thereafter, examined by a geotechnical engineer to obtain more accurate descriptions of the

existing soil strata. Laboratory testing was performed on selected samples as deemed necessary to aid in

soil classification and to further define the engineering properties of the soils. No laboratory tests were

deemed necessary.

Page 5: Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately

Report of Subsurface Soil Exploration 13-MAR-2014Proposed Directional Drill Project No.14-33-4512Under S.R. 80, East of Birchwood Parkway Page No. 4Port LaBelle, Hendry County, Florida

Ardaman & Associates, Inc.

The soil descriptions shown on the log are based upon visual-manual procedures in accordance with local

practice. Soil classification is in general accordance with the Unified Soil Classification System (ASTM D-

2487) and is also based on visual-manual procedures.

GENERAL COMMENTS

While the boring is representative of subsurface conditions at its location and for its vertical reach, local

variations characteristic of the subsurface materials of the region are anticipated and may be encountered.

The boring log and related information are based on the driller's log and visual examination of selected

samples in the laboratory. The delineation between soil types shown on the log is approximate and the

description represents our interpretation of subsurface conditions at the designated boring location and on the

particular date drilled.

If you have any questions about this report, please contact this office.

Very truly yours,

Ardaman & Associates, Inc.Florida Certificate of Authorization No. 00005950

Gary A. Drew, P.E.Vice President/Branch ManagerLicense No. 35504

GAD/egs

Distribution:Client – 2 hard copies + electronic pdf

Page 6: Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately

Ardaman & Associates, Inc.

ATTACHMENT

SPT BORING LOG

Page 7: Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately

0

3

6

9

12

15

18

21

3- 3- 3

2- 2- 2

3- 7- 16

8- 9- 12

50/0"- -

4- 5- 4

6

4

23

21

50/0"

9

1

2

3

4

5

6

7

SP

SC

SM

SP-SM

Poorly Graded Sand - Brown fine sand.

Clayey Sand - Brown clayey fine sand.

Silty Sand with Gravel - Light gray calcareoussilty fine sand, some gravel- size limerockfragments (Soft Limestone) .

Hard Limestone.

Poorly Graded Sand with Silt - Light graycalcareous slightly silty medium to fine sand,trace to some gravel-size shell fragments andcemented sands.

TERMINATED AT 20.5'

Hand augered to 4.5'Safety hammer usedfrom 4.5' to TERM

BORING LOCATION: LOCATION PROVIDED BY TETRA TECH CLIENT: TETRA TECH (IER)STATION: N26 46.013' OFFSET: W081 22.803' PROJECT: DIRECTIONAL BORE UNDER S.R. 80

EAST OF BIRCHWOOD PARKWAYDATE DRILLED: 06-MAR-14 START: FINISH:GROUND SURFACE ELEVATION: TIME: LOCATION: PORT LABELLE, HENDRY CO., FLWATER TABLE DEPTH (ft): 7.5' DATE: 06-MAR-14 DRILL CREW: WOOTEN/SLEE LOGGED BY: G. DREW

DRILL MAKE & MODEL: CME-55 BIT: 3-7/8" DIA TRICONE ROLLER DRILLING RODS: NWDRILLING METHOD: ROTARY WASH WITH DRILLING FLUID WEATHER CONDITIONS: OVERCAST/MILD

PAGE 1 OF

REVIEWED BY: GARY A. DREW, P.E. FILE NO: 14-33-4512 BORING NO.: SPT-1

DEP

TH

, FT

.

BLOWS

SPT

N-V

ALU

E

SA

MPL

E N

O.

GRA

PHIC

LO

G

USC

S

SOIL DESCRIPTION REMARKS

% W

ATER

CO

NTEN

T

PERC

ENT

FIN

ES

% O

RG

AN

ICC

ON

TEN

T

LIQ

UID

LIM

IT

PLA

ST. IN

DEX

1

Page 8: Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately

Ardaman & Associates, Inc.

APPENDIX

SOIL BORING, SAMPLING AND TESTING METHODSPROJECT SOIL DESCRIPTION PROCEDURE – UNIFIED

Page 9: Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately
Page 10: Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately
Page 11: Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately
Page 12: Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately
Page 13: Ardaman & Associates, Inc. Geotechnical, …dnhiggins.com/docs/2015-04 GeoTech Rpt..pdfwill be installed under S.R. 80 by directional drilling. The location of the water main is approximately