Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Are design or the size of the trawl affecting
the cod-end selectivity?
Marine Research Institute
Haraldur Arnar Einarsson MRI-Iceland
And
Ólafur Arnar Ingólfsson IMR-Norway
2 / 14Haraldur Arnar Einarsson
IntroBasics about the method
Codend design
• Nephrops trawl
Different method same codend
• One or two codend on the same trawl
Circumferences
• large commercial trawl
Different codends netmaterial on two different designed trawls
• Results within codeds on different trawls
• Results within trawls with different codends
Summary
Conclusion
3 3 / 14Haraldur Arnar Einarsson
Cover codend
50mm mesh in the cover with 40 mm meshes in the codend
Small kites lift the net from the codend in test
Basics about the method
Method
Test codend
Cover 50mm
4 4 / 14Haraldur Arnar EinarssonCodend design
Codend design
Two mesh sizes with two different circumferences each
90mm with 100 (normal ) and 134 (wide ) meshes around
105mm with 86 (normal ) and 114 (wide ) meshes around
5 / 14Haraldur Arnar EinarssonDifferent method
Same
One or two codend on the same trawl
Last year a trial with horizontal divided trawl in comparison with same trawl with one codend
The same codend was measured with cover codend method as single codend and as upper
codend at the divided trawl
Mesh size was 135mm (lower codend on the divided one was 155mm)
6 / 14Haraldur Arnar EinarssonDifferent method
One coded upper codend One coded upper codend
One coded upper codend One coded upper codend
SR
7 / 14Haraldur Arnar EinarssonCommercial
January 2013:
A selectivity measurements was done on board
in a commercial bottom trawler with common trawl
1. T90 in 120mm
2. Normal 135mm (100mesh)
3. Narrow 135mm (60 mesh )
Örfirisey RE 4
Bacalao
8 / 14Haraldur Arnar Einarsson
Narrow coded normal codend Narrow coded normal codend
Commercial
Same codend with 135mm meshes but different circumferences
9 / 14Haraldur Arnar Einarsson
Redesign on six day selectivity survey now in September (1-6 / 9)
Two trawls same codends
Two different trawls, both in size and design
On both trawls two different codends was measured with cover codend
36,6 Headline 70,2
22,6 Fishing-line 40
41 Length 81
45,5 Extension 90.5
Different cut on belly
14° ~8°
10 / 14Haraldur Arnar EinarssonTwo trawls same codends
Two codends tested
Green codend
Mesh 135mm
2x6mm PE
1040 g/100m
Yellow codend
Mesh 135mm
2x6,2mm PE
1585 g/100m
Same circumference
Same length
11 / 14Haraldur Arnar EinarssonTwo trawls same codends
12 / 14Haraldur Arnar EinarssonTwo trawls same codends
13 / 14Haraldur Arnar Einarsson
Summary
Summary
Mesh size is far from be the most important factor for codend selectivity
Circumference is a strong factor for codend selectivity
Wider codend reduces L50
Narrower codend increses L50
How the codend is used affects selectivity
- Two codend instead of one
- Grids in front of the codend....?
Codend material (twine) affects the selectivity
But it can vary greatly between the same codend attached
on different trawl
Trawl size and/or design has significant effect on codend selectivity
14 / 14Haraldur Arnar Einarsson
Conclusions
Conclusions
If laws or regulations are meant for promoting the wanted
selectivity from the gear. The whole design of the trawl and
codend must be taken into account.
Results from codend selectivity is only representative for the
codend in the trial and the trawl it is attached to.