Upload
others
View
16
Download
0
Embed Size (px)
Citation preview
Tech
nica
l spe
cific
atio
ns su
bjec
t to
chan
ge w
ithou
t prio
r not
ice
| 20
1510
| ©
KoC
oS M
esst
echn
ik A
G
S Y S T E M C O N C E P T
ARTES 460 | 560 test systems are compact, robust, lightweight and quiet. LEDs on the front panel indicate the states and operating modes of the inputs and outputs.
ARTES 460 | 560The Universal Relay Testing Solution
ARTES 460 | 560 test systems are compact solutions for testing all types of protection relays. The built-in control panel, light weight and low noise level make these robust test systems equally suitable for use on site and in the lab.
ARTES 460 | 560 makes light work of highly complex tests on static and digital protection relays. Thanks to the six current outputs, even three-phase tests on differential protection relays can be carried out without additional equipment.
www.kocos.com
S P E C I F I C AT I O N S
www.kocos.com
S O U R C E S
4 independent voltage channels up to 300 V6 independent current channels up to 32 AWide frequency rangeSeparate auxiliary power supply
F L E X I B L E P O W E R I N G
Operation with AC or DC power supplyCan be used in any countryImmune to disturbances in the power supply
E R G O N O M I C & R O B U S T D E S I G N
Sophisticated connection systemAll connections and controls are located on the front panelA wide range of communication interfaces
E A S Y T O U S E
Stand-alone operation with a 3.5“ touch screenErgonomic menu and intuitive operationSoftware for automatic tests and evaluationLEDs for status indication
ARTES 460 | 560
KoCoS Measurement & Control (PTY) Ltd.40 Jeanette Street, Brackenfell, 7560PO Box 3585, Durbanville, 7551 Cape Town, South AfricaPhone +27 21 [email protected]
RE
LA
Y T
ES
T S
YS
TE
MS
A
RT
ES
46
0|5
60
For more information, go to:
Sources Separately and independently configurable
Frequency range DC...3 kHz
Transient signals DC...4 kHz
Phase angle 0...360°
Voltage amplifiers 2 switchable output ranges
300 V output range 4-ph.: 4 x 0...300 V / 75 VA 1-ph.: 1 x 0...600 V / 150 VA
150 V output range 4-ph.: 4 x 0...150 V / 75 VA1-ph.: 1 x 0...300 V / 150 VA
Current amplifiers ARTES 4606-ph.: 6 x 0...16 A / 40 VA3-ph.: 3 x 0...32 A / 80 VA
ARTES 5606-ph.: 6 x 0...32 A / 100 VA3-ph.: 3 x 0...64 A / 200 VA
Low-level signal outputs Separately and independently configurable
Output range 10 x 0...10 Vpk
DC output 12...260 V, overload and short-circuit protection
Output power 50 W (across the entire output range)
Analog inputs 2 switchable measuring ranges
Measuring ranges 4 x 0…±10 V / 600 Vrms
4 x 0…±20 mA / 0…±10 V
Binary inputs Configurable as potential-free/potential-carrying contacts
Quantity / Groups 8 / 2
Binary outputs 2 potential-free and galvanically isolated output relays
Switching capacity AC 0...250 V / 8 A
Switching capacity DC 0...300 V / 8 A
Supply voltage 100...265 VAC / 120...265 VDC
Rated frequency 47...63 Hz
Interfaces USB, Ethernet
Housing 19“ portable
Dimensions (mm) 470 x 162 x 316 (W x H x D)
Weight ARTES 460: 10 kg ARTES 560: 15 kg
[ ENG ]
New!
TJCP Operator Interface
. High-resolution, resistive 3.5“ touch screen
. Ergonomic jog wheel for fast, easy settings
. An illuminated ring and acoustic signals indicate system status during settings and tests
. USB and Ethernet interface for direct connection to PCs and networks
. Smart touch technology for easy operation
. User actions, such as amplitude, phase angle or frequency adjustments, are processed in real time and executed without delay
. Test settings can be selected from templates
P O W E R F U L V E R S AT I L EE R G O N O M I C
A new operating concept and extra powerful hardware make the relay test system speedier than ever before. The test instrument responds directly to user actions and can switch fast from one menu to another, all processes run swiftly and smoothly.
The clear, restructured user interface guides the user quickly and intuitively to complete the task in hand. The individual screens are self-explanatory and uncluttered.
•• •
DC - Aux. Binary Input Binary Input
24 V Group 1 Wet Group 2 Wet
Remote
Remote
USB
ETH
00:0000:00
000
000
•
DeltaControl
74 0057. 1.
50.0 0˚
Voltage (V) Current (A)
LineangleFrequency (Hz)
SelectMonitor
U1
57,74
57,74 240
0 50,0
50,0
I2 I3I1I5 I6I4
U2 U3 U4
U1 VHz
Hz
°
°VU2
00:0000:00
000
000
dU
dI
dPhi
df
SelectMonitor
(V)
(A)
(Hz)
•
•
•
•
DeltaOff
DeltaOff
DeltaOff
DeltaOff
DeltaOff
DeltaOff
Voltage IPSU-Volt
Current
Frequecy
300
200
16
V
Hz
A
5 V
Preset 1Default
Limits Device VD Static
Symmetric
00:0000:00
000
000
SelectMonitor
Bin Out #1
Bin Out #2
•
•
manual
2,5 s
#1#5
#6
#7
#8
#2
#3
#4
Trg ---
Trg ---
Trg ---
Trg ---
Trg ---
Trg ---
Trg ---
Trg ---
0:00:09284
0018
0:00:09492
0226
00:0000:00
000
000
dU
dI
dPhi
df
SelectMonitor
(V)
(A)
(Hz)
•
•
•
•
Channel Mag Phi [deg.] f [Hz]
U1 AC 57,74V 0 50, 0
U2 AC 57,74V 240 50, 0
U3 AC 57,74V 120 50, 0
U4 Off
I1 AC 1,00A 0 50, 0
I2 AC 1,00A 240 50, 0
I3 AC 1,00A 120 50, 0
I4 AC 1,00A 0 50, 0
I5 AC 1,00A 240 50, 0
I6 AC 1,00A 120 50, 0
START VALUES
00:0000:00
000
000300 V
12 A
Imax: 16A
Umax: 300 V
dU
dI
dPhi
df
(V)
(A)
(Hz)
•
•
•
•
300 V
300 V
12 A
12 A
1 A1 A1 A
SelectMonitor
The new TJCP Operator Interface!