Technical

Instructions

Manual

FACE-BOW AND ARTICULATOR

www.bioart.com.br

Page 2: Articulador Manual Ing

Authorised Representative in the European Community:

PANADENT LTD149, Sevenoaks Way, Orpington, Kent, Br5 3AQ, ENGLANDTel. +44 (0) 1689 881788 - Fax. +44 (0) 1689 881789E-mail: [email protected] web: www.panadent.net

NOTE:

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any electronic, mechanical, photocopyng, recording or other means, without the prior writen consent of Bio-Art Equipamentos Odontológicos Ltda.

BIO-ART EQUIPAMENTOS ODONTOLÓGICOS LTDA.Rua Teotônio Vilela, 120 - Jardim Tangará

CEP 13568-000 - São Carlos - SP - Brasil

Tel. +55 (16) 3371-6502 - Fax +55 (16) 3372-5953 - MS: 103682-4

Home Page: www.bioart.com.br E-mail: [email protected]

D.: C

MA

N0

01

4 -

Re

v. N

° 0

02

- 0

9/1

1/2

00

7

Page 3: Articulador Manual Ing

CONTENTS

01 - Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01

02 - Standard and Professional Face-Bow registration procedure . . . . . . . . 022.1 - Dentate and partially dentate patients . . . . . . . . . . . . . . . . . . . . . . 022.2 - Totally edentureless patient . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04

03 - Mounting the casts on the Articulator . . . . . . . . . . . . . . . . . . . . . . . . . . . 053.1 - Preparing the Articulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 053.1.1 - Articulator Model 4000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 053.1.2 - Articulator Model 2000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 063.1.3 - Articulator Model A7 Plus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 063.1.4 - Articulator Model A7 Fix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 063.1.5 - Articulator Model EVA Plus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 073.1.6 - Articulator Model EVA Fix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 07

3.2 - Mounting the upper cast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 083.2.1 - Standard Face-Bow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 083.2.2 - Professional Face-Bow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 09

3.3 - Interocclusal Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

3.4 - Mounting the Mandibular Cast . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

04 - Special features of the Bio-Art Articulators . . . . . . . . . . . . . . . . . . . . . . . 13

05 - Special features of the Standard and Professional Face-Bows . . . . . . . 14

06 - Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

07 - Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

08 - Technical Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

09 - Garantee. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

10 - Part List Articulator 2000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

11 - Part List Articulator 4000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

12 - Part List Articulator A7 Plus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

13 - Part List Articulator A7 Fix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

14 - Part List Articulator EVA Plus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

15 - Part List Articulator EVA Fix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

16 - Part List Standard Face-Bow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

17 - Part List Professional Face-Bow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Page 4: Articulador Manual Ing

1 - INTRODUCTION

IMPORTANT NOTE: Before using your BIO-ART articulator, please read carefully all the

Instructions Manual.

The BIO-ART semi-adjustable articulators are Arcon type conventional equipment (models

2000, 4000, A7 Plus and A7 Fix) and Non-Arcon type (models EVA Fix and EVA Plus).

Therefore, the mounting technical procedures are the same for these articulators.

IMPORTANT NOTE: The use of the equipment by professionals not qualified can cause

damage or harm to the product and/or patient.

The articulator is an instrument used to simulate the maxillo-mandibular relation and

movements of a patient in a laboratory, with the purpose of studying the occlusion and

production of dental devices that will be used by the patient. These devices include complete

dentures, partial dentures, bridges, crowns and bite plate, among others.

The face-bow is an instrument used to register the position of the patient's dental arcade in

relation to the skull and transfer this record to the articulator.

This Manual contains only basic and simplified information regarding the use of the

equipment, which do not replace the need of a specific course of Occlusion and/or

Prosthesis, offered in many Teaching Institutions and Dental Faculties, as a compulsory

discipline.

The articulator and face-bow’s use are restricted to qualified professionals.

It is important to emphasize, however, that the semi-adjustable articulator and face-bow

provide a simple, fast and highly precise way of reproducing the human mandible movements,

enabling the dental professional to carry out corrective and restorative dentistry tasks more

easily, rapidly and at lower costs than those of traditional, time-consuming techniques

involving expensive and highly complex equipment. Furthermore, the semi-adjustable

articulator and face-bow produce far more accurate results than those produced by “simple

hinge” articulators, which involve arbitrary mounting of the mandibular cast on the device and

whose movements are also limited.

The use of the semi-adjustable articulator and face-bow is therefore recommended for most

prosthetic, occlusal and rehabilitation work. The technique is simple, fast and easy, offering

highly satisfactory results for both the patient and professional.

01

Page 5: Articulador Manual Ing

2 - STANDARD AND PROFESSIONAL FACE-BOWREGISTRATION PROCEDURE

FIG. 1

FIG. 2

FIG. 3

FIG. 4

FIG. 5 FIG. 6 FIG. 7

2.1 - DENTATE AND PARTIALLY DENTATE PATIENTS

a) By using bite registration material (“godiva”, wax, among others) three points on the fork are made: one frontal point, in the exact centre of the fork, and two points at the back, one at each semi-arch of the fork (fig.1).

b) Position the bite fork so that the midline of the fork handle is aligned with the midline of the maxilla and place it on the upper teeth, holding it firmly in place until the registration material hardens (fig. 2). Only a small amount of registration material should be used since the purpose is to record only the cusp tips of the teeth while keeping the fork as immobile as possible (fig. 3).Afterwards it is advisable to try the cast on the registration to check its stability (absence of clearance) (fig. 4).Note: Alternatively, a pre-impression of the teeth can be made on the upper model and then refined in the mouth. In the case of patients who have partially jagged teeth, it is important to locate points that hold the fork stably in place, despite the missing teeth and the points used for the transfer.

c) Recline the patient in the chair to reduce the induction of tensions on the fork set and face-bow asking him to keep the fork in the same position, supporting the thumbs against the maxilla (fig. 5). Take the face-bow to the patient and introduce the fork fixation assembly into the bite fork handle, assuring that the wing nut is upside down (fig. 6). Then carefully insert the face-bow earpieces into the patient's external auditory meatus as if you were putting a stethoscope into his ears (fig. 7).

02

Page 6: Articulador Manual Ing

FIG. 9

FIG. 10

FIG. 11

FIG. 12 FIG. 13 FIG. 14

d) Place the nasion relator on the face-bow cross bar, when using the face-bow Standard or on the “W” of the face-bow, when using the Professional Face-Bow. For both models, centre the nosepiece on the patient's nasion. The earpieces should now be carefully positioned as deeply as possible in the patient's auditory meatus and the nosepiece should be gently pressed against the patient's nasion while tightening the wing nuts of the nazion relator assembly (fig. 8). Afterwards, tighten the three screws of the Standard face-bow or the central screw when using the Professional model (fig. 9 and 14).

e) With the nazion relator and the face-bow tightened and the patient holding the fork immobile, push the fork fixation assembly forward, sliding it on the fork handle until it is as close as possible to the lips, without touching them, in order to achieve increased stability. Then tighten the wing nuts of the fork: first the double articulated nut (connection block) (fig. 3) and then the horizontal slide bar nut, so that the fork is supported at one end of its handle, resulting in less tension on it (fig. 10 and 11). To ensure proper registration, ask the patient to remove his thumbs from the bite fork and check if the fork and the face-bow are stable and immobilized (fig. 12).

f) When using the articulator model 4000, record the approximate intercondylar distance, whose reading is taken on the front edge of the face-bow Standard or above the “W” for the Professional face-bow (fig. 13 and 14). The three numbers (1, 2 and 3), separated by a reference mark, correspond to the intercondylar distances: small, medium and large. When the reference mark is aligned with the distance indicator, always use the smallest distance for the patient. This information should be registered in the patient´s records for subsequent adjustment of the articulator.

Note: In other articulator models, the intercondylar distance is fixed at an average of 110mm and the intercondylar distance is not adjustable. In this case, disregard the above-described registration of the face-bow.

FIG. 8

STANDARD FACE-BOW PROFESSIONAL FACE-BOW

Central Screw

Intercondylardistance

IntercondylarDistance

DistanceIndicator

03

Page 7: Articulador Manual Ing

g) Loosen the wing nut of the nosepiece and remove the nazion relator assembly from the face-bow. Then, loosen the central wing nut of the face-bow and hold the cross bar of the bow at the same time the patient opens the mouth slowly, removing the whole set carefully (fig. 15, 16 and 17)

FIG. 16

FIG. 19

FIG. 15

FIG. 18

FIG. 17

FIG. 20

2.2 - TOTALLY EDENTURELESS PATIENT

a) When registering totally edentureless patients with the face-bow, use the special edentureless fork, or Conti fork (optional), to maintain the prove plate and roller wax.

b) After the patient's registration on the wax roller, heat both handles of the fork slightly in a flame and press them on the upper wax roller, which was previously joined to the lower wax roller, or not, with the midline of the fork handle aligned with the midline of the patient (fig. 18, 19).

c) Place the set (fork + wax rollers) in the patient's mouth inserting it on the alveolar edges (fig. 20)

Note: When carrying out the registration with wax rollers which were previously joined, ask the patient to keep it in position and close his mouth.

d) Repeat steps (c) to (g) of item 2.1

04

Page 8: Articulador Manual Ing

3 - MOUNTING THE CASTS ON THE ARTICULATOR

3.1 PREPARING THE ARTICULATOR

The adjustments of the articulators mentioned below are only used to mount the casts on the articulator. However, the professional may choose to use other angulation techniques to personalize the settings.

The marks 1, 2 and 3 of the Face Bows are used to adjust the intercondylar distance (small, medium, large), when the mounting is carried out with the Articulator Model 4000. For the other articulators models, it must be ignored.

3.1.1 Articulator Model 4000

a) Fix the condylar elements into the lower frame holes according to the patient's registration (1, 2 and 3) made with the face-bow. With the help of the condylar element shaft, tighten the condylar elements slightly (fig. 21).

b) Adjust the same intercondylar distance in the upper frame, expanding or closing the condylar guide with the micrometric expanding spindle (fig. 22). Note: To facilitate adjustment of the intercondylar distance of the upper frame using the micrometric spindle, leave the wing screw of the condylar guide inclination slightly loose.The relationship between the intercondylar distance and the positioning of the condylar guide is given as follows:*Small = without expansion (condylar guide totally closed)*Medium = first marking on the condylar guide axle*Large = second marking on the condylar guide axle

Important: A fine adjustment should be made to prevent lateral movements of the upper frame in relation to the lower frame observing that the position of the condylar elements should be touching the posterior and superior walls of the condylar guide and the lateral of the bennet angle adjusting device simultaneously (fig. 23) i.e., the reference mark for the adjustment of the intercondylar distance in the condylar guide axle does not always coincide with the correct position of adjustment of the upper frame. A fine adjustment is therefore necessary, using the expanding spindle.

c) Adjust the condylar guide at a 30° angle and a negative “Benett” angle (fig. 24 and 25), assuring the stability of the articulator at a central position and place the spring latch assembly on the lower frame.

FIG. 21

FIG. 22

FIG. 23

FIG. 24

FIG. 25

05

Page 9: Articulador Manual Ing

3.1.2 - Articulator Model 2000

Adjust the condylar guides at a 50º angle and the immediate side shift at 0 (zero) millimeters. Close the central lock assuring that there are no lateral movements and fasten the condylar guide elastic in the lower frame (fig. 26, 27 and 28).

FIG. 26 FIG. 27 FIG. 28

FIG. 29 FIG. 30 FIG. 31

3.1.3 - Articulator Model A7 PlusTo facilitate the mounting of the casts, adjust the Condylar Guides angles at 30º and the Bennet at 0º (fig. 29 and 30). Then push back the upper part of the central lock until feel the “click” (locked position fig. 31).

PS.: In order to make sure that the Articulator A7 Plus is totally locked at the centric position, check if the 2 locks (left and right) are at the locked position.

FIG. 32 FIG. 33 FIG. 34

3.1.4 - Articulator Model A7 FixAiming as main characteristic simplicity and easiness to work, the A7 Fix Articulator was developed with the Bennet and Condyle angles fixed at the average of 15° and 30°, respectively. The intercondilar distance was also fixed at the average of 110 mm. Therefore, this model does not require preliminary adjustments for these components, such as the other models previously mentioned. In order to lock the Articulator A7 Fix in the centric position, there is an innovative system with two lateral pins, denominated: “centric lock pin”. This pin has 3 main positions: first position - totally closed (locks the articulator in the centric position - picture 32); second position - intermediate (releases the articulation movements - picture 33) and third position (allows to remove the upper from the lower frame - picture 34).

06

Page 10: Articulador Manual Ing

FIG. 36 FIG. 37FIG. 35

IMPORTANT NOTE:

The horizontal slide bar lock screw of the Articulators Model EVA PLus and EVA Fix (see this item on the Part List), are used to calibrate the equipment at the plant and should not be unfasten or removed. This procedure can disadjust the equipment.

FIG. 38

3.1.5 - Articulador Modelo EVA Plus:Adjust the condylar guide at a 30° angle and the “Benett” angle at a 0° (zero) (fig. 35 and 36). Tighten the right and left screws, assuring that there are no lateral movements (fig. 37)

3.1.6 - Articulator Model EVA Fix

Tighten the right and left screws, assuring that there are no lateral movements (fig. 38)

07

Page 11: Articulador Manual Ing

08

The Standard face-bow should only be used with the articulator model 2000, 4000 and 5000. It should not be used with the EVA Fix and EVA Plus models.

a) Fix the face-bow Standard to the upper frame of the articulator by fitting the earpiece holes on the small pins located on the external edge of the condylar guide (fig. 39).

b) Support the front part of the Articulator Upper Frame on the cross bar of the face-bow. Close the face-bow firmly by fastening the central face-bow wing nut and placing the whole face-bow together with the upper frame on the lower frame of the articulator (fig. 40,41 and 42).

c) Place the upper cast, with retentions and previously hydrated, on the fork registration. Lift the Upper Frame of the articulator, depositing a small amount of plaster on the Upper Mounting Plate and a portion on the top of the Upper Cast. Then, using one of your hands, keep the fork and the cast in position, avoiding any movement of the Bite Fork and carefully hinge the Upper Frame until it touches the cross bar of the face-bow. Wait for the plaster to harden (fig. 43).

Note: The sides of the mounting plates, which are in contact with the articulator frames, should be devoid of plaster.

Important: In order to achieve greater stability and precision during the transfer procedure, it is advisable to use the Fork Support (optional) and plaster type IV (fig. 44).

d) Remove the face-bow from the articulator.

FIG. 39

FIG. 41

FIG. 40

FIG. 43FIG. 42 FIG. 44

Fork support (optional) Fork support (optional)

3.2 - MOUNTING THE UPPER CAST

3.2.1 Standard face-bow

Page 12: Articulador Manual Ing

09

FIG. 47FIG. 46 FIG. 48

FIG. 49 FIG. 50 FIG. 51

FIG. 45

3.2.2 - Professional face-bow

The main feature of this model is the Jig Transfer Assembly for mounting the casts on the articulator (fig. 45). This assembly is placed in the lower frame of the articulator through the Jig assembly lower base thus eliminating the need for the face-bow arm while transferring the patient's registration onto the articulator and providing quick mounting of the cast, easy handling, greater stability, precision and reliability.

a) Remove the incisal guiding table from the lower frame of the articulator and insert the jig transfer lower base, assuring that the guide pin is properly touching the end of the slot (reference point) (fig. 46,47 and 48).

b) Remove the jig transfer assembly from the face-bow by releasing its respective wing nut, connect it to the jig transfer lower base and fasten the wing nut (fig. 49 and 50).

c) Insert the upper frame support on the jig transfer connection rod, supporting the upper frame and assuring the parallelism among the articulator frames (fig. 51).

Page 13: Articulador Manual Ing

10

FIG. 54

FIG. 55

d) Place the upper cast, with retentions and previously hydrated, on the fork registration. Lift the Upper Frame of the articulator, depositing a small amount of plaster on the Upper Mounting Plate and some on the top of the Upper Cast (fig. 52). Then, using one of your hands, keep the fork and the cast in position, avoiding any movement of the Bite Fork and carefully hinge the Upper Frame until it touches the support. Wait for the plaster to harden.

Note: The sides of the mounting plates, which are in contact with the articulator frames, should be devoid of plaster.

Important: In order to achieve greater stability and precision during the transfer procedure, it is advisable to use the Fork Support (optional) and plaster type IV (fig. 53).

3.3 - INTEROCCLUSAL REGISTRATION

To set up the mandibular (lower) cast in the articulator, you should have a record correlating the upper and lower dental arches, according to the purpose of the mounting, in one of the following ways:Maximum Intercuspation (MI);Centric Relation (CR);

These records can be made using material of the operator's preference: wax, resins, addition or condensation silicon, etc. (fig. 54 and 55)

To obtain the M.I registration, place the selected material to register the patient's arcade and ask him to occlude.There are several techniques to obtain the R.C registration, i.e. Peter Dawson's technique (bilateral manipulation of the mandible), Lucia's JIG technique and James Long (use of plastic spacer) among others.

Note: For totally edentureless patients, this registration is made when the upper and lower wax rollers are joined based on the correct dimensions of the patient.

FIG. 52

FIG. 53

Fork support (optional)

Fork support (optional)

Wax registration

Silicon registration

Page 14: Articulador Manual Ing

11

3.4 - MOUNTING THE MANDIBULAR CAST

a) Place the Incisal Guide Pin in the Upper Frame of the

articulator with its rounded tip pointing downward so that

the upper and lower frames are parallel, i.e. on the zero

marking of the Incisal Guide Pin (fig. 56)

b) Now turn the articulator upside down on the laboratory

bench and affirm the lower cast, with retentions and

previously hydrated, upon the interocclusal register that

should be placed in the mounted upper cast (fig. 57). In

totally edentureless patients, this was obtained by

joining the wax rollers together.

c) We recommend fixing the casts with rubber bands or

staples (fixed with “godiva” or wax) so that they remain in

position until the plaster hardens. Place a small amount

of plaster on the lower part of the mandibular cast and a

small amount on the mounting plate of the lower frame of

the articulator to fill in the gap between them (fig. 58).

d) Make sure the condylar elements are duly positioned

and close the lower frame until the Incisal guide pin

touches the Incisal table. Afterwards, fasten the

articulator frames using rubber bands to prevent

possible distortion occurred by the plaster expansion

(fig. 59)

Note: The sides of the mounting plates, which are in

contact with the articulator frames, should be devoid of

plaster.

e) After the plaster hardens, turn the articulator back to its

upright position (lower frame resting on the laboratory

bench) and complete the work, filling the cast fixation

towers with plaster for the finishing touches (fig. 60).

FIG. 56

FIG. 57

FIG. 58

FIG. 59

FIG. 60

TROCARA FOTO

Page 15: Articulador Manual Ing

3.5 - FEATURES OF THE RAIL MOUNTING PLATE

The possibility of reusing the Mounting Plate without breaking the model requires care with the side finishing of the plaster on the plate, i.e., the plate should not have plaster at the lateral border (picture 61).

In order to take off the model, the plaster should be removed of from the retention hole (picture 62) and then the model should be hold while tapping the plate towards the indicated arrows located on the lower face of it (picture 63).

PS.: Once the model has been taken off the Mounting Plate, we can not guarantee the returning of it in the initial position with precision, since it depends on the technical quality of the work and the materials used (especially the plaster).

FIG. 61 FIG. 62 FIG. 63

12

Page 16: Articulador Manual Ing

* Ad

justm

en

t ma

de

thro

ug

h th

e m

icrom

etrica

l exp

an

din

g sp

ind

le. (B

io-A

rt's exclu

sive syste

m)

** Join

ing

system

be

twe

en

the

up

pe

r an

d lo

we

r fram

es p

rovid

es sta

bility d

urin

g a

rticula

ting

mo

vem

en

ts.

Inte

rch

an

ge

ab

le A

rticu

lato

rs (O

ptio

na

l)B

io-A

rt's inte

rcha

ng

ea

ble

articu

lato

rs are

stan

da

rdize

d (ca

libra

ted

) by th

e m

an

ufa

cture

r to a

llow

for in

terch

an

ge

ab

ility of th

e ca

sts am

on

g th

ese

a

rticula

tor m

od

els. O

nly m

od

els 2

00

0, 5

00

0 a

nd

EV

A ca

n b

e su

pp

lied

in th

e sta

nd

ard

ized

op

tion

.

4 - S

PE

CIA

L F

EA

TU

RE

S O

F T

HE

BIO

-AR

T A

RT

ICU

LA

TO

RS

13

Mo

d. A

7 F

ixM

od

. A7

Mo

d. E

VA

Fix

Mo

d. E

VA

Plu

s

Adjustable / C

urve

Silicone C

onnection

Fixed at 110 m

mF

ixed at 110 mm

Fixed at 110 m

mF

ixed at 110 mm

Arcon

Adjustable / F

lat

Adjustable

Adjustable *

No

Central S

pringM

agnetic ***S

prin

g in

the

con

dyle

gu

ide

Sp

ring

in th

eco

nd

yle g

uid

e

No

Arcon

Arcon

Fixed at 15°

Adjustable

Yes

Yes

Yes

Yes

No

No

No-A

rcon

Flat

Curve

Fixed at 30°

Fixed at 30°

Fixed at 15°

No

No A

rcon

Adjustable / F

lat

Adjustable

No

Yes

No

No

No

No

4000A

7 Fix

A7

Eva F

ixE

va Plu

s

Mo

d. 2

00

0M

od

. 40

00

2000

Classification

Condylar G

uide

Bennet A

ngle

Intercondylar Distance

Central Lock

Stabilization S

ystem **

Imm

ediate Side S

hift

Protrusion A

djustment

Arcon

Adjustable / C

urve

Fixed at 15°

Fixed at 110 m

m

Rubber R

ing (O'ring)

Yes

Adjustable

No

Mo

del

Featu

res

Page 17: Articulador Manual Ing

5 - SPECIAL FEATURES OF THE STANDARD ANDPROFESSIONAL FACE-BOWS

5.1 - STANDARD FACE-BOW

The Bio-Art Standard model is simple and easy to work with. It has manually tightened wing nuts to fix the fork, eliminating the inconvenient use of the key. In this model, the registration of the position of the patient's upper dental arcade in relation to the skull is transferred to the articulator by setting the complete face-bow in the upper frame assembly of the articulator (chapter 3 Item 3.2.1)

5.2 - PROFESSIONAL FACE-BOW

The main feature of this model is the Jig Transfer Assembly for mounting the casts on the articulator, eliminating the need for the face-bow arm while transferring the patient's registration, providing greater quality, stability, precision and reliability (ref. chapter 3, item 3.2.2). The design of the face-bow ensures more stability concerning the opening and closing movement in relation to the fork, or in other words, the fork is fixed when the face-bow moves. The auricles are anatomic, removable and chemically sterilized ensuring comfort for the patient.

The Standard Face Bow can be used with the all Articulators models, its use is forbidden with the Models EVA Fix and EVA Plus.

The Professional Face Bow can be used with any Bio-Art Articulator model.Jig Transfer Assembly

14

5.3 - IINSTRUCTIONS FOR USE THE NOSE PIECE SUPPORT

Slide the Nose Piece Support in the Face-Bow's Cross Bar through the groove, pressing it until realize a slight "click" indicating that the support is fully embedded. The support may be laterally moved, so that it can be placed in the position desired by the operator (fig. 64).

To withdraw the Nose Piece Support, make a movement of twist to facilitate its removal (fig. 65).

FIG. 64

FIG. 65

Page 18: Articulador Manual Ing

7 - SAFETY RULES

• This manual only contains basic and simplified information regarding the use of the instrument and under no circumstances it is a substitute for a proper training course. The articulator and face-bow are products aimed at the exclusive use of qualified dental professionals.

• The Bio-Art face-bow is designed for use with Bio-Art's own articulator and vice-versa. Although, the Standard face-bow is compatible with other articulator models, its use with similar models should be consulted. The Professional face-bow is exclusively designed for use with the Bio-Art articulator. Therefore, Bio- Art does not guarantee precision when its face-bows are used with other products.

• Bio-Art articulators are not interchangeable, i.e. the casts mounted on one articulator model should not be transferred (mounted) to any other articulator. Therefore, Bio-Art does not guarantee precision when casts mounted on one articulator are transferred to another.

• The only Bio-Art articulators, which are interchangeable, are those which are calibrated in the factory. Thus, for safe and precise interchangeability, casts should be transferred only between calibrated articulators.

• Before using the articulator and face-bow, the professional should check the instrument for possible damage, distortion of the incisal pin, face-bow's parallelism, proper centricity of the incisal pin in relation to the lower frame, etc. Should any abnormality be found, Bio-Art's Technical assistance or Authorized Representative should be contacted immediately.

• The face-bow should be cleaned with warm water prior to its use. The Bite Fork must be autoclaved and the Earpieces disinfected with a bactericide or with 70° alcohol.

• Bio-Art recommends only warm water for the general cleaning of the articulator and face- bow.

• When using “godiva” or any other registration material, special care should be taken to avoid excessive heating of the material, which might burn the patient's mouth. Bio-Art urges the user to carefully follow the instructions of the registration material manufacturer.

• Because the articulator is a precision instrument, it should be handled, transported and stored carefully. Bio-Art provides a plastic case (optional accessory) exclusively designed to accommodate the articulator and to facilitate its transportation.

15

6 - ACCESSORIES

Magnetic Mounting Plate

Toothless Fork (Adjustable)

Fox RulerRail Plate Camper's Plane Exclusive Plastic Case

Adjustable Incisal Guiding Table (Metallic)

Fork Support

Page 19: Articulador Manual Ing

9 - GUATANTEE

16

BIOART Dentistry Equipment Ltd guarantees the ARTICULATOR for one year. This guarantee covers any manufacturing fault in the case of repairing the product.

The following conditions must be met:

a) The product had to have been used correctly according to the instructions. We remind you that the ARTICULATOR should be handled, transported and stored carefully. Dropping or knocking the device means bad use and this will result in losing the guarantee.

b) The receipt of the purchase of the product must be attached to the complaint

To make use of this guarantee, the consumer should send the product (at his/her own cost) to the nearest authorized BIOART Technical Assistance or to the following address:

Rua Teotônio Vilela, 120 Jardim TangaráCEP 13568-000 São Carlos/SP Brazil

Tel: +55 (16) 3371 6502 Fax +55 (16) 3372 5953CNPJ 58.538.372/0001-56 I.E.637.034.447.113

Home page: www.bioart.com.br Email: [email protected]

Natural wear and tear of the product, as well as damage caused by transportation (both ways) are excluded from this guarantee.

8 - TECHNICAL SERVICE

For your safety, the technical service of this product should be made by people/companies authorized by BIO-ART. Please contact us or the distributors, where the product was acquired.Our web site is: www.bioart.com.br

Page 20: Articulador Manual Ing

17

10

PA

RT

LIS

T -

- A

RT

ICU

LA

TO

R 2

00

0

Item

Qt

Co

de

De

sc

riptio

n

012

SC

RE

0008C

ondylar Guide W

ing Screw

022

FF

IX0057

Condylar G

uide Pin

031

FC

TZ

0068C

entric Pin

041

FC

DL0072

Condylar G

uide (Right)

052

FP

IG0062

Face B

ow's G

uide Pin

062

CPA

R0231

Elastic's S

crew of C

ondylar Guide

074

CO

RI0029

Condylar G

uide Elastic

082

FE

CD

0049C

ondyle Elem

ent

091

FH

ST

0058C

ondyle Elem

ent Shaft

104

CPA

R0230

Elastic's S

crew of Low

er Fram

e

111

FR

AM

0066Low

er Fram

e

124

FP

LM0064

Mounting P

late

134

FP

IG0076

Mounting P

late Guide P

in

142

SC

RE

0010M

ounting Plate K

nob

151

SC

RE

0002Incisal Table W

ing Screw

161

FM

ES

0063Incisal G

uiding Table (Polycarbonate)

171

ST

RA

0016C

entral Lock

182

CPA

R0348

Central Lock A

llen Screw

191

FP

IN0053

Incisal Guide P

in

201

SC

RE

0011Incisal G

uide Pin W

ing Screw

211

FALH

0073S

ide Shift G

uide (Left)

221

FR

AM

0065U

pper Fram

e

231

FC

DL0071

Condylar G

uide (Left)

241

FALH

0074S

ide Shift G

uide (Right)

252

CPA

R0034

Centric P

in Screw

262

CA

NE

0008W

asher for Mounting P

late Knob

272

SC

RE

0020C

ondylar Guide W

ing Screw

Page 21: Articulador Manual Ing

18

11P

AR

T L

IST

-

-

A

RT

ICU

LA

TO

R 4

00

0

Ite

mQ

tC

od

eD

es

cri

pti

on

012

SC

RE

0008

Con

dila

r G

uide

Win

g S

crew

022

FF

IX00

57C

ondy

lar

Gui

de P

in

031

FF

US

0042

Mic

rom

etric

Exp

andi

ng S

pind

le

042

SC

RE

0009

Con

dyla

r G

uide

Win

g S

crew

051

FC

DL0

046

Con

dyla

r G

uide

(rig

ht)

062

FP

IG00

62F

ace

Bow

's G

uide

Pin

071

FALH

0047

Ben

nett

Ang

le A

djus

ting

Dev

ice

(rig

ht)

082

FE

CD

0049

Con

dyle

Ele

men

t

091

FH

ST

0058

Con

dyle

Ele

men

t Sha

ft

101

FR

AM

0050

Low

er F

ram

e

114

FP

LM00

64M

ount

ing

Pla

te

122

SC

RE

0010

Mou

ntin

g P

late

Kno

b

131

SC

RE

0002

Inci

sal T

able

Win

g S

crew

141

FM

ES

0063

Inci

sal G

uidi

ng T

able

(P

olic

arbo

nate

)

151

FP

IN00

53In

cisa

l Gui

de P

in

161

SC

RE

0011

Inci

sal G

uide

Pin

Win

g S

crew

171

FALH

0048

Ben

nett

Ang

le A

djus

ting

Dev

ice

(left)

181

FR

AM

0056

Upp

er F

ram

e

191

FB

CH

0059

Con

dyla

r B

ush

(Lef

t)

201

FC

DL0

045

Con

dyla

r G

uide

(le

ft)

211

FB

CH

0060

Con

dyla

r B

ush

(Rig

ht)

222

CP

IE00

05S

topp

ing

Pin

231

FR

LD00

61P

ulle

y

244

FP

IG00

76M

ount

ing

Pla

te G

uide

Pin

252

CA

NE

0008

Was

her

for

Mou

ntin

g P

late

Kno

b

261

FP

IN00

06S

prin

g La

tch'

s P

in

271

CM

OL0

007

Spr

ing

Latc

h

Page 22: Articulador Manual Ing

19

1 -

AR

TIC

UL

AT

OR

2

PA

RT

LIS

T -

A7

PL

US

Item

Qty

Co

de

De

sc

riptio

n1

1S

CR

E0078

Incisal table screw2

1F

RA

M0731

Lower fram

e3

1F

ME

S0063

Incisal table (acrylic)4

1F

TAP

0761F

inishing cover of right column

51

FAG

U0753

Occlusal plan indicator

61

FP

IN0750

Incisal pin with hole

71

FR

AM

0740U

pper frame

81

SA

LH0075

Bennett angle adjusting device (R

ight) 9

1S

GU

I0073C

ondylar guide (right)10

2F

PIN

0744S

tabilizing elastic band pin11

1F

PO

S0759

Position indicator of B

ennett angle adjusting device (right)12

2F

PAR

0742S

crew to fix the B

ennett angle adjusting device 13

1F

PIN

0743U

pper frame support pin

142

FT

RA

0765Lock of upper fram

e15

2C

AN

E0319

Condylar guide O

-ring16

1C

ET

Q1113

Model identification label

172

FF

IX0766

Condylar guide fixer

182

SC

RE

0008C

ondylar guide screw19

1F

TAP

0764P

ulley finishing cover20

1F

PO

S0758

Position indicator of B

ennett angle adjusting device (left)21

1S

GU

I0072C

ondylar guide (left)22

1S

ALH

0074B

ennett angle adjusting device (Left) 23

4F

PIG

0076M

ounting plate guide pin24

2F

CA

N0755

Magnetic fitting

252

CIM

A1118

Mounting plate m

agnetic26

2S

PLA

0079M

ounting plate (track)27

1S

CR

E0011

Incisal pin screw28

2C

PAR

1119C

ondylar element screw

292

CM

OL1100

Stabilizing elastic band

302

FE

CD

0734C

ondylar element

312

FP

IG0788

Face bow

's guide pin32

1F

TAP

0760F

inishing cover of left column

331

SC

RE

0082M

ounting plate screw (low

er frame)

341

SC

RE

0010M

ounting plate screw (upper fram

e)

Page 23: Articulador Manual Ing

Ite

mQ

tyC

od

eD

es

cri

pti

on

11

SC

RE

0078

Inci

sal t

able

scr

ew2

1F

RA

M07

31Lo

wer

fram

e3

1F

ME

S00

63In

cisa

l tab

le (

acry

lic)

41

FP

IN07

50In

cisa

l pin

with

hol

e5

1FA

GU

0753

Occ

lusa

l pla

n in

dica

tor

61

FTA

P07

61F

inis

hing

cov

er o

f rig

ht c

olum

n7

2F

PIN

0756

Lock

pin

of c

entr

ic p

ositi

on (

artic

ulat

or)

82

FP

IG07

79F

ace

bow

's g

uide

pin

91

SR

AM

0080

Upp

er fr

ame

101

FP

IN07

43U

pper

fram

e su

ppor

t pin

111

FTA

P07

77M

agne

t fin

ishi

ng c

over

(R

ight

)12

2C

IMA

1111

Sta

biliz

er m

agne

t13

1C

ET

Q11

14M

odel

iden

tific

atio

n la

bel

141

FTA

P07

78M

agne

t fin

ishi

ng c

over

(Le

ft)15

2C

IMA

1118

Mou

ntin

g pl

ate

mag

net

162

SP

LA00

79M

ount

ing

plat

e (t

rack

)17

1S

CR

E00

11In

cisa

l pin

scr

ew18

2C

PAR

1119

Con

dyla

r el

emen

t scr

ew19

2C

OR

I111

2O

-rin

g of

lock

pin

202

FE

CD

0752

Con

dyla

r el

emen

t 21

1F

TAP

0760

Fin

ishi

ng c

over

of l

eft c

olum

n22

2F

CA

N07

55M

agne

tic fi

tting

232

FP

IG00

76M

ount

ing

plat

e gu

ide

pin

242

SC

RE

0082

Mou

ntin

g pl

ate

scre

w

20

13

- P

AR

T L

IST

-

AR

TIC

UL

AT

OR

A7

FIX

Page 24: Articulador Manual Ing

21

1 -

AR

TIC

UL

AT

OR

EV

A P

LU

S4

PA

RT

LIS

T -

Item

Qt

Co

de

De

sc

riptio

n01

02C

PAR

0548C

olumn S

crew02

02F

BA

S0483

Colum

n Base

0302

SC

RE

0010M

ounting Plate K

nob04

01F

RA

M0474

Lower F

rame

0502

CA

NE

0008W

asher for Mounting P

late Knob

0604

FP

IG0076

Mounting P

late Guide P

in07

04F

PLM

0064M

etallic Mounting P

late08

01F

CO

L0500C

olumn (R

ight)09

01F

CA

B0499

Bennet A

ngle Adjusting H

ead (Right)

1002

FAR

R0504

Adjusting H

ead Lock Washer

1101

FT

RA

0503A

djusting Head Lock P

in12

01F

TR

A0501

Condylar G

uide Lock (Right)

1301

FH

ST

0514P

rotrusion Adjustm

ent Screw

-Driver

1402

FT

RA

0502C

ondylar Guide W

edge Lock15

02F

PAR

0513P

rotrusion Adjustm

ent Screw

1602

CA

NE

0805R

ubber O’R

ing17

02F

ES

F0482

Condylar S

phere18

02F

EIX

0484H

orizontal Slide B

ar19

01F

GU

I0498C

ondylar Guide (R

ight)20

02C

LIM0554

Condylar S

phere Limiter

2102

CM

OL0031

Condylar S

phere Limiter S

pring22

03S

CR

E0011

Incisal Guide P

in Wing S

crew23

01C

ET

Q0634

PV

C Label

2402

FPA

R0485

Horizontal S

lide Bar Lock S

crew25

01F

PIN

0692S

tabilization Pin (E

xtension)26

01F

GU

I0506C

ondylar Guide (Left)

2701

FP

IN0481

Support P

in28

01F

RA

M0475

Upper F

rame

2901

FT

RA

0520C

ondylar Guide Lock (Left)

3001

FT

RA

0519A

djusting Head Lock P

in (Left)31

01F

CA

B0507

Bennet A

ngle Adjusting H

ead (Left)32

01F

CO

L0509C

olumn (Left)

3301

FP

IN0053

Incisal Guide P

in34

01F

ME

S0063

Incisal Guiding Table (P

olycarbonate)35

01S

CR

E0002

Incisal Table Wing S

crew36

01C

ET

Q0016

Identification Label37

02FA

LA0505

Condylar G

uide Lever38

02FA

LA0521

Bennet A

ngle Lever39

01F

HS

T0058

Horizontal S

lide Bar S

haft

Page 25: Articulador Manual Ing

22

1 -

A

RT

ICU

LA

TO

R E

VA

FIX

5P

AR

T L

IST

-

Ite

mQ

tC

od

eD

es

cri

pti

on

0102

CPA

R05

48C

olum

n S

crew

0202

FB

AS

0483

Col

umn

Bas

e

0302

SC

RE

0010

Mou

ntin

g P

late

Kno

b

0401

FR

AM

0474

Low

er F

ram

e E

va A

rtic

ulat

or

0502

CA

NE

0008

Was

her

for

Mou

ntin

g P

late

Kno

b

0604

FP

IG00

76M

ount

ing

Pla

te G

uide

Pin

0702

FC

OL0

476

Col

umn

Eva

Art

icul

ator

0804

FP

LM00

64M

etal

lic M

ount

ing

Pla

te

0902

CA

NE

0805

Con

dyla

r S

pher

e Lo

ck W

ashe

r

1002

FE

SF

0482

Con

dyla

r S

pher

e

1102

FE

IX04

84H

oriz

onta

l Slid

e B

ar

1202

FG

UI0

477

Con

dyla

r G

uide

1302

CLI

M05

54C

ondy

lar

Sph

ere

Lim

iter

1402

CM

OL0

031

Con

dyla

r S

pher

e Li

mite

r S

prin

g

1501

CE

TQ

0635

PV

C L

abel

1603

SC

RE

0011

Inci

sal G

uide

Pin

Win

g S

crew

1702

FPA

R04

85H

oriz

onta

l Slid

e B

ar L

ock

Scr

ew

1801

FP

IN04

81S

uppo

rt P

in

1901

FR

AM

0475

Upp

er F

ram

e E

va A

rtic

ulat

or

2001

FP

IN00

53In

cisa

l Gui

de P

in

2101

FM

ES

0063

Inci

sal G

uidi

ng T

able

(P

olyc

arbo

nate

)

2201

CE

TQ

0016

Iden

tific

atio

n La

bel

2301

SC

RE

0002

Inci

sal T

able

Win

g S

crew

2401

FH

ST

0058

Con

dyle

Ele

men

t Sha

ft

2501

FP

IN06

92S

tabi

lizat

ion

Pin

(E

xten

sion

)

Page 26: Articulador Manual Ing

23

1 -

STA

ND

AR

D F

AC

E-B

OW

6P

AR

T L

IST

-

Item

Qt

Co

de

De

sc

riptio

n

12

SB

BL

00

01

Win

g scre

w

21

FF

IX0

36

2P

iece

to fix th

e cro

ss ba

r (with

ou

t ho

le)

32

FM

OL

00

25

Ela

stic wa

she

r

41

SE

XP

00

06

Ho

rizon

tal slid

e b

ar

51

STA

R0

00

5C

ross b

ar

61

FP

NZ

00

20

No

se p

iece

sup

po

rt

75

SC

RE

00

20

Fa

ce-b

ow

win

g scre

w

81

FH

ST

00

18

No

se p

iece

sha

ft

91

FB

LO

00

16

No

se p

iece

10

1FA

RC

07

84

Fa

ce-b

ow

arm

(Rig

ht)

111

FA

UR

00

33

Ea

r pie

ce (R

igh

t)

12

1C

ET

Q0

01

8M

od

el id

en

tificatio

n la

be

l

13

1FA

UR

00

32

Ea

r pie

ce (L

eft)

14

1C

EL

A0

00

9E

lastic b

an

d

15

1FA

RC

07

85

Fa

ce-b

ow

arm

(Le

ft)

16

1F

PO

R0

03

9C

en

ter n

ut

17

1S

GD

E0

00

7B

ite fo

rk

18

1F

BL

O0

00

8C

on

ne

ction

Blo

ck (inte

rna

l)

19

2F

TM

P0

02

7S

top

pin

g scre

w

20

1F

BL

O0

00

6C

on

ne

ction

blo

ck (exte

rna

l)

21

1C

AR

R0

00

4W

ash

er fo

r the

blo

ck

22

1F

BL

O0

02

6F

ork´s co

nn

ectio

n b

lock

23

1C

PIE

00

05

Affixin

g b

lock p

in

24

1F

FIX

00

22

Affixin

g b

lock (w

ith h

ole

)

Page 27: Articulador Manual Ing

24

1 -

P

RO

FE

SS

ION

AL

FA

CE

-BO

W7

PA

RT

L

IST

-

Ite

mQ

tC

od

eD

es

cri

pti

on

14

SB

BL

00

01

Win

g s

cre

w2

1F

PIG

00

09

Guid

e p

in o

f tr

ansf

ere

nce

set (low

er

base

)

31

SC

RE

00

02

Inci

sal t

ab

le s

cre

w4

1F

BA

S0

00

2T

ran

sfe

ren

ce s

et lo

we

r b

ase

52

CO

RI0

00

2T

ran

sfe

ren

ce s

et co

lum

n O

-rin

g

61

FC

OL

00

07

Tra

nsf

ere

nce

se

t co

lum

n7

1F

TM

P0

02

7S

top

pin

g s

cre

w

81

FB

LO

05

60

Co

nn

ect

ion

Blo

ck (

inte

rna

l)9

1S

EX

P0

00

4H

orizo

nta

l slid

e b

ar

10

1F

BL

O0

55

9C

on

ne

ctio

n b

lock

(e

xte

rna

l)

111

CA

RR

00

04

Wa

she

r fo

r th

e b

lock

12

1F

BL

O0

56

1F

ork

´s c

on

ne

ctio

n b

lock

13

1C

PIE

00

05

Affix

ing

blo

ck p

in

14

1C

AP

O1

07

4U

pp

er

fra

me

su

pp

ort

15

2F

MO

L0

02

5E

last

ic w

ash

er

16

1F

FIX

00

22

Affix

ing

blo

ck (

with

ho

le)

17

1S

GD

E0

00

3B

ite fo

rk1

81

FA

RC

05

82

Fa

ce-b

ow

(L

eft)

19

2FA

UR

00

19

Ea

r p

iece

20

1C

ET

Q0

02

5M

od

el i

de

ntif

ica

tion

lab

el

21

2F

PO

R0

02

1F

ace

-bo

w n

ut

22

1F

HS

T0

01

8N

ose

pie

ce s

ha

ft2

31

FB

LO

00

16

No

se p

iece

24

1FA

RC

05

81

Fa

ce-b

ow

(R

igh

t)2

53

SC

RE

00

20

Fa

ce-b

ow

win

g s

cre

w2

61

CP

OR

10

23

Ce

nte

r n

ut

27

1F

PN

Z0

02

0N

ose

pie

ce s

up

po

rt2

82

CP

AR

02

30

Up

pe

r b

ase

scr

ew

29

1F

WW

W0

58

3F

ace

-bo

w "

W"

30

2F

PA

R0

01

7Jo

int sc

rew

31

1F

BA

S0

00

3T

ran

sfe

ren

ce s

et u

pp

er

ba

se

32

1F

FIX

03

62

Pie

ce to

fix

th

e c

ross

ba

r (w

itho

ut h

ole

)

Page 28: Articulador Manual Ing

Rua Teotônio Vilela, 120 - Jd. Tangará - CEP 13568-000 - São Carlos - SP - Brasil

Tel. +55 (16) 3371-6502 - Fax +55 (16) 3372-5953

Home Page: www.bioart.com.br E-mail: [email protected]