ASIF IQBAL Junior Supervisor House No. A293, Street No. 08 Block # 9, Gulistan-e-Johar, Karachi PAKISTAN. Contact # (Pakistan): +923333214611 E-mail: [email protected] OBJECTIVE To serve in a progressive organization offering jobs satisfaction a challenging work environment and a vast opportunity for career development. WORKING EXPERIENCE OVER 08 YEARS SINCE FEBRUARY 2007 AS QA/QC AND NDT INSPECTOR JUNIOR SUPERVISOR INSPECTION (FAUJI FERTILIZER BIN QASIM LTD. KARACHI, PAKISTAN) Manufacturing of ‘UREA’ AND ‘DI-AMMONIA PHOSPHATE’ (DAP). It is one of the most significant Plant in Pakistan. Currently Working On FCPL (FFBL Power Company Limited) 118MW Project as an Inspection Supervisor. STATIONARY EQUIPMENT INSPECTION: VESSELS / COLOUMS / TANKS / HEAT EXCHANGERS / BOILERS. Detailed internal inspection of above mentioned stationary equipments Ultrasonic thickness monitoring of in service vessels / columns / shells of heat exchangers. Dye Penetrate Testing of welding inside columns and vessels. Widely used NDT technique as pre requirement (Normal & High temperature) Magnetic Particle Inspection (Fluorescent and Contrast Paint) methods. Witness hydrostatics and leak testing / SFT of exchangers / boilers and piping. Coating thickness measurement using Delta scope MP-2c Inspection of corrosion under insulation. Hardness measurement of different materials. Holiday test of rubber lining of tanks.

Asif Iqbal CV

Embed Size (px)

Citation preview

Page 1: Asif Iqbal CV

ASIF IQBALJunior SupervisorHouse No. A293, Street No. 08Block # 9, Gulistan-e-Johar, KarachiPAKISTAN.

Contact # (Pakistan): +923333214611E-mail: [email protected]

OBJECTIVE To serve in a progressive organization offering jobs satisfaction a challenging work environment and a vast opportunity for career development.

WORKING EXPERIENCE OVER 08 YEARS SINCE FEBRUARY 2007 AS QA/QC AND NDT INSPECTOR

JUNIOR SUPERVISOR INSPECTION (FAUJI FERTILIZER BIN QASIM LTD. KARACHI, PAKISTAN) Manufacturing of ‘UREA’ AND ‘DI-AMMONIA PHOSPHATE’ (DAP). It is one of the most significant Plant in Pakistan.

Currently Working On FCPL (FFBL Power Company Limited) 118MW Project as an Inspection Supervisor.

STATIONARY EQUIPMENT INSPECTION: VESSELS / COLOUMS / TANKS / HEAT EXCHANGERS / BOILERS.

Detailed internal inspection of above mentioned stationary equipments Ultrasonic thickness monitoring of in service vessels / columns / shells of

heat exchangers. Dye Penetrate Testing of welding inside columns and vessels. Widely used

NDT technique as pre requirement (Normal & High temperature) Magnetic Particle Inspection (Fluorescent and Contrast Paint) methods. Witness hydrostatics and leak testing / SFT of exchangers / boilers and

piping. Coating thickness measurement using Delta scope MP-2c Inspection of corrosion under insulation. Hardness measurement of different materials. Holiday test of rubber lining of tanks.

ROTARY EQUIPMENT INSPECTION:

VIBRATION MONITORING

Routine and planned casing vibration monitoring of rotary equipment using DATAPAC 1500 and Dynamics-2500 instruments.

Live vibration monitoring using BENTLY NEVADA ADRE-SXP408. Phase measurement. RPM monitoring using stroboscope and tachometer.

NDT OF ROTARY PARTS:

Page 2: Asif Iqbal CV

NDT techniques on machine parts e.g. DPT, MPT, Hardness testing, Material analysis of rotors / wheels /impellers / shafts / bearings etc.

PIPING INSPECTION: Thickness monitoring of in service critical plant piping to insure reliable /incident free

plant operation. External visual inspection of pipeline to see any rust /corrosion and also the condition

of pipe support especially of steam network. CUI corrosion under insulation Inspection. Holiday testing of wrapping of underground pipelines. Hydrostatics testing. Inspection of leaked piping box-up. Verify the piping box-up.

WELDING INSPECTION: Visual Welding Inspection Of Welds Ferrite contents measurement in critical SS equipment’s and welds joints using Ferrite

Scope MP30. Witness of the welder qualification as per ASME IX QW-461.4

MOSTLY USED NDT TECHNIQUES: Skin Temperature measurement using contact and Non-contact type

thermometer.

Material Analysis with (Alloy Analyzer OMEGA XPD-2000).

Inspection of corrosion under insulation.

Coating thickness measurement using Delta scope MP-2c.

Valve inspection.

Radiographic Testing.

Magnetic Particle Testing.

Crane/Load Testing.

Dye Penetrant Testing

Boroscopy of heat exchanger tubes.

Hardness testing of different materials using EQUO-TIP.

Surface Profile Measurements.

Holiday testing.

QC Responsibilities: Inspection and acceptance to customer supplied materials, contractor

supplied materials such as Plates, Pipes, Fittings, as per requirements of

the Specifications.

Review of material test certificates as per Codes, Standards and

specification.

Review of Welding Procedure specification and Welder Qualification

records as per ASME-IX, AWS D1.1

Witnessing the WQT AS PER ASME Sec IX.

Welding Inspection & NDT inspection of Heavy Structural, Pressure

Vessels, Tank & Tank Nozzles, Pipe fit up & alignment.

Witness of Hydro test and Pneumatic test

Documentation of Quality records

Preparation of reports against NDT results like RT, MPT, DPT, and

Thickness monitoring etc.

ACADEMIC QUALIFICATION: B-Tech (Mechanical “A” Grade)

Page 3: Asif Iqbal CV

D.A.E (Mechanical “A” Grade)

Matriculation (Science)

PROFESSIONAL COURSE: Radiographic Testing Level – I course from NCNDT Islamabad in 2012

with second position.

SAFETY, HEALTH & ENVIRONMENT TRAINING:

Training on Fire Fighting equipment

Permit to Work System (PTW) Annual

ANNUAL TURNAROUND EXPERIENCES: Annual Turnaround 2015 at Fauji Fertilizer Bin Qasim Limited. Annual Turnaround 2014 at Fauji Fertilizer Bin Qasim Limited. Annual Turnaround 2013 at Fauji Fertilizer Bin Qasim Limited. Annual Turnaround 2012 at Fauji Fertilizer Bin Qasim Limited. Annual Turnaround 2011 at Fauji Fertilizer Bin Qasim Limited. Annual Turnaround 2011 at Fauji Fertilizer Company –Mirpur Mathelo. Annual Turnaround 2010 at Fauji Fertilizer Bin Qasim Limited. Annual Turnaround 2010 at Fauji Fertilizer Company – Goth Machhi. Annual Turnaround 2009 at Fauji Fertilizer Bin Qasim Limited. Annual Turnaround 2008 at Fauji Fertilizer Mirpur Mathelo. Annual Turnaround 2007 (DAP Revamp) at Fauji Fertilizer Bin Qasim

Limited.

PERSONAL DETAIL

Father’s Name : IQBAL HUSSAIN C. N.I.C No : 42201-3392510-7 Date of Birth : 5th Feb 1986 Language : English, Urdu Nationality : Pakistani Marital Status : Married