2
Rapid nebulization Rapid nebulization minimizes duration of the procedure and makes it more comfortable for the patient Minimal residual volume Minimal residual volume of medicines after the inhalation for treatment efficacy APS Technology APS technology allows generating the aerosol with the different particle size for efficient treatment of upper and lower respiratory tract Nasal washer Nasal washer is efficient for cold treatment and everyday hygiene (cleaning) of a cavity of a nose. It can be used for children and adults There are accessories for both children and adults Mouthpiece, nosepiece, child mask, adult mask FEVER MANAGEMENT Digital Thermometers T-10 T-20 Turbo Car Turbo Train Turbo Mini Turbo Pro Turbo Base Turbo Flow T-30 model breast pump BPA free two-stages pumping painless and fast milk expression imitating the baby’s natural sucking fast expression of much milk adjustable suction power ergonomic handle standard/wide neck adaptor soft breast shield for maximum comfort GM-20 manual yes yes yes yes yes yes yes yes yes GM-10 manual yes yes yes yes yes yes GM-30 electric yes yes yes yes yes yes yes model measuring time waterproof flexible tip fever alarm memory automatic switch-off warranty T-10 60 sec no no yes last memory yes 2 years T-20 10 sec yes no yes last memory yes 2 years T-30 10 sec yes yes yes last memory yes 2 years GM-10 GM-20 GM-30 Inhalation therapy is the latest, effective and convenient method of asthma management. Nebulizer guarantees deep medicine penetration to the site of inflammation as well as a possibility of delivering of high doses of drugs. Twist medicine cup to MAX position. In this position particle size of aerosol generated will be 6 microns (MMAD). This mode is sufficient for treatment: - ARD - ARVI - pharyngitis - laryngitis Twist medicine cup to MIN position. In this position particle size of aerosol generated will be 3 microns (MMAD). This mode is sufficient for treatment: - bronchitis - bronchial asthma Distribution of Aerosol Particles within Respiratory Tract ASTHMA MANAGEMENT ASTHMA MANAGEMENT Advantages Compressor Nebulizers BABY LINE Breast Pumps model type nebulization rate particle size (MMAD) possibility to nebulize antibacterial and hormonal drugs nebulizer capacity cleaning and disinfection sound noise level operating cycle nasal washer weight size warranty Turbo Car compressor from 0,2 to 0,4 ml/min 3 - 6 microns with regulation MMAD (APS-Technology) yes 2-12 ml boiling and/or dipping into disinfectant according to info in the user’s manual around 55 Db 30 min - ON / 30 min - OFF yes/ no (optional) 1400 g 230×165×140 mm 2 years Turbo Train compressor from 0,2 to 0,4 ml/min 3 - 6 microns with regulation MMAD (APS-Technology) yes 2-12 ml boiling and/or dipping into disinfectant according to info in the user’s manual around 55 Db 30 min - ON / 30 min - OFF optional 1500 g 235×110×165 mm 2 years model type nebulization rate particle size (MMAD) possibility to nebulize antibacterial and hormonal drugs nebulizer capacity cleaning and disinfection sound noise level operating cycle nasal washer weight size warranty Turbo Flow compressor from 0.2 to 0.4 ml/min 3 - 6 microns with regulation MMAD (APS-Technology) yes 2 - 12 ml boiling and/or dipping into disinfectant according to info in the user’s manual around 55 dB 30 min on/30 min off optional 1300 g 204х145х132 mm 2 years Turbo Mini compressor 0.2 ± 0.4 ml/min 3 - 6 microns with regulation MMAD (APS-Technology) yes 2 - 12 ml boiling and/or dipping into disinfectant according to info in the user’s manual around 55 dB 30 min on/30 min off optional 1300 g 167х106х164 mm 2 years Turbo Pro compressor from 0.2 to 0.4 ml/min 3 - 6 microns with regulation MMAD (APS-Technology) yes 2 - 12 ml boiling and/or dipping into disinfectant according to info in the user’s manual around 55 dB continuous use optional 1500 g 253х192х102 mm 2 years Turbo Base compressor ≥ 0.25 ml/min 3 microns yes 10 ml rinsing, 30 min dipping into disinfectant below 55dBA 20 min - ON / 40 min - OFF no 1460 g 110x110x62 mm 2 years 2-5 μm - settling in the lower respiratory tract 5-10 μm - settling in the larynx, tracheae, upper bronchi 0,5-2 μm - settling in the alveoli particles less than 0,5 μm do not settle in the respiratory tract > 10 μm - settling in the oropharynx M I N I M A L R E S I D U A L V O L U M E bronchioles bronchi trachea larynx MAX (II) II MIN (I) I two-stages pumping compact and portable for the whole family wide range of medications used intensive use Low noise level Low noise level is an important feature for children who can be afraid of noise

ASTHMA MANAGEMENT ASTHMA MANAGEMENT FEVER … · Turbo Train 3 - 6 microns with regulation MMAD (APS-Technology) yes 2-12 ml boiling and/or dipping into disinfectant according to

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ASTHMA MANAGEMENT ASTHMA MANAGEMENT FEVER … · Turbo Train 3 - 6 microns with regulation MMAD (APS-Technology) yes 2-12 ml boiling and/or dipping into disinfectant according to

Rapid nebulizationRapid nebulization minimizes duration of the procedure and makes it more comfortable for the patient

Minimal residual volumeMinimal residual volume of medicines after the inhalation for treatment efficacy

APS TechnologyAPS technology allows generating the aerosol with the different particle size for efficient treatment of upper and lower respiratory tract

Nasal washerNasal washer is efficient for cold treatment and everyday hygiene (cleaning) of a cavity of a nose. It can be used for children and adults

There are accessories for both children and adultsMouthpiece, nosepiece, child mask, adult mask

FEVER MANAGEMENT

Digital Thermometers

T-10 T-20

Turbo Car Turbo Train

Turbo Mini Turbo Pro

Turbo Base

Turbo Flow

T-30

model

breast pump

BPA free

two-stages pumping

painless and fast milk expression

imitating the baby’s natural sucking

fast expression of much milk

adjustable suction power

ergonomic handle

standard/wide neck adaptor

soft breast shield for maximum comfort

GM-20

manual

yes

yes

yes

yes

yes

yes

yes

yes

yes

GM-10

manual

yes

yes

yes

yes

yes

yes

GM-30

electric

yes

yes

yes

yes

yes

yes

yes

model

measuring time

waterproof

�exible tip

fever alarm

memory

automatic switch-o�

warranty

T-10

60 sec

no

no

yes

last memory

yes

2 years

T-20

10 sec

yes

no

yes

last memory

yes

2 years

T-30

10 sec

yes

yes

yes

last memory

yes

2 years

GM-10 GM-20 GM-30

Inhalation therapy is the latest, effective and convenient method of asthma management. Nebulizer guarantees deep medicine penetration to the site of inflammation as well as a possibility of delivering of high doses of drugs.

Twist medicine cup to MAX position. In this position particle size of aerosol generated will be 6 microns (MMAD). This mode is sufficient for treatment:- ARD- ARVI- pharyngitis- laryngitis

Twist medicine cup to MIN position. In this position particle size of aerosol generated will be 3 microns (MMAD). This mode is sufficient for treatment:- bronchitis- bronchial asthma

Distribution of Aerosol Particles within Respiratory Tract

ASTHMA MANAGEMENT ASTHMA MANAGEMENT

Advantages Compressor Nebulizers

BABY LINE

Breast Pumps

model

type

nebulization rate

particle size (MMAD)

possibility to nebulize antibacterial and hormonal drugs

nebulizer capacity

cleaning and disinfection

sound noise level

operating cycle

nasal washer

weight

size

warranty

Turbo Car

compressor

from 0,2 to 0,4 ml/min

3 - 6 microns with regulation MMAD (APS-Technology)

yes

2-12 ml

boiling and/or dipping into disinfectantaccording to info in the user’s manual

around 55 Db

30 min - ON / 30 min - OFF

yes/no (optional)

1400 g

230×165×140 mm

2 years

Turbo Train

compressor

from 0,2 to 0,4 ml/min

3 - 6 microns with regulation MMAD (APS-Technology)

yes

2-12 ml

boiling and/or dipping into disinfectantaccording to info in the user’s manual

around 55 Db

30 min - ON / 30 min - OFF

optional

1500 g

235×110×165 mm

2 years

model

type

nebulization rate

particle size (MMAD)

possibility to nebulize antibacterial and hormonal drugs

nebulizer capacity

cleaning and disinfection

sound noise level

operating cycle

nasal washer

weight

size

warranty

Turbo Flow

compressor

from 0.2 to 0.4 ml/min

3 - 6 micronswith regulation MMAD

(APS-Technology)

yes

2 - 12 ml

boiling and/or dippinginto disinfectant

according to info in the user’s manual

around 55 dB

30 min on/30 min o�

optional

1300 g

204х145х132 mm

2 years

Turbo Mini

compressor

0.2 ± 0.4 ml/min

3 - 6 micronswith regulation MMAD

(APS-Technology)

yes

2 - 12 ml

boiling and/or dippinginto disinfectant

according to info in the user’s manual

around 55 dB

30 min on/30 min o�

optional

1300 g

167х106х164 mm

2 years

Turbo Pro

compressor

from 0.2 to 0.4 ml/min

3 - 6 micronswith regulation MMAD

(APS-Technology)

yes

2 - 12 ml

boiling and/or dippinginto disinfectant

according to info in the user’s manual

around 55 dB

continuous use

optional

1500 g

253х192х102 mm

2 years

Turbo Base

compressor

≥ 0.25 ml/min

3 microns

yes

10 ml

rinsing, 30 min dippinginto disinfectant

below 55dBA

20 min - ON / 40 min - OFF

no

1460 g

110x110x62 mm

2 years

2-5 µm -settling in the lower

respiratory tract

5-10 µm -settling in the larynx,

tracheae, upper bronchi

0,5-2 µm -settling in the alveoli

particles less than 0,5 µmdo not settle

in the respiratory tract

> 10 µm -settling in theoropharynx

MIN

IMAL

RES

IDUAL VOLUME

bronchioles

bronchi

trachealarynx

MAX (II)II

MIN (I)I

two-stagespumping

compact andportable

for the wholefamily

wide range ofmedications used

intensiveuse

Low noise level Low noise level is an important feature for children who can be afraid of noise

Page 2: ASTHMA MANAGEMENT ASTHMA MANAGEMENT FEVER … · Turbo Train 3 - 6 microns with regulation MMAD (APS-Technology) yes 2-12 ml boiling and/or dipping into disinfectant according to

CAM technology - Clinically Accurate MeasurementIn CAM mode, 2 measurements (at 20 sec break) are automatically taken in succession and the result is then automatically analyzed and displayed. If sys BP1- sys BP 2 >/= 15 mmHg, dia BP1 - dia BP2 >/= 10 mmHg, CAM mode will automatically start the 3rd measurement after another 20 sec countdown. In case the 1st and/or 2nd pulse rate </= 60, device will automatically take 4 times measurement in succession.Because people’s blood pressure constantly fluctuates, a result determined in this way is more reliable than the one produced by a single measurement.

IHB TechnologyIt is a new technology for irregular heartbeat detection. If irregular heartbeat is detected during the measurement of blood pressure, LCD displays the icon of irregular heartbeat .

Average of All Stored MemoriesBlood pressure monitors with the function of average of all stored results display this value at first. Touching the MEMORY (or M/SET) button you can see this value on the display.

Blood Pressure Level Indicator Blood pressure level indicator helps a user to self-orient in measurement results. Blood pressure level indicator classified from ESH (European Society of Hypertension) standards is located along the left side on the display.

HYPERTENSION MANAGEMENT

Advantages / Digital Blood Pressure Monitors

HYPERTENSION MANAGEMENT

Aneroid Blood Pressure Kits / Stethoscopes

12

6

39

technologytechnology

technologytechnology

1 measurement 2 measurement

3 measurement

12

6

39

technologytechnology

3 measurement 4 measurement

START

20 sec countdown

If sys BP1 - sys BP 2 >/= 15 mmHg dia BP1 - dia BP2 >/= 10 mmHg

If 1st and/or 2nd pulse rate </= 60 beat/min

12

6

39

MeasurementResult Displaying

M-300A M-100A M-200A M-150S

S-10 S-20 S-30

A-40A-20A-10

model

type

arrhythmia detection

CAM technology(Clinically Accurate Measurement)

average

WHO blood pressure rate indicator

memory

cu� size

soft bag

adapter

warranty

M-100A/Optional

Automatic Upper arm

yes

nono/

average of 3last measurement (optional)

yes

1/90 (optional)

M (22-32 cm)

yes

yes/no (optional)

5 years

M-300A

Automatic Upper arm

yes

yes

all stored values

yes (ESH bar)

90

22-42 cm

soft bag

yes

5 years

M-200A/Optional

Automatic Upper arm

yes

no

average of 3 last measurement/average of morning and nighttime measurements(optional)

yes

2 x 30/2 x 90 (optional)

M-L (22-42 cm)

yes

yes/no (optional)

5 years

M-150S

Semi-automatic Upper arm

yes

no

yes

1

M (22-32 cm)

yes

5 years

model

aneroid blood pressure kit

sphygmomanometer

cu�

stethoscope

soft bag

warranty

A-20

classic

beryl-zinc mechanism

comfort 22-36 cmwith �xing metallic ring

yes

yes

2 years

A-10

professional

beryl-zinc mechanism

professional 25 – 42 cm

no

yes

2 years

A-40

comfort

beryl-zinc mechanism

comfort 22-36 cmwith �xing metallic ring

built-in chest piece

yes

2 years

model

stethoscope type

ear-tips

chest piece

binaural

«Y» tubing

warranty

S-10

single head

ergonomic

lightweight aluminum

reliable chrome-plated

one-piece molded PVC

2 years

S-20

dual head

ergonomic

lightweight aluminum

reliable chrome-plated

one-piece molded PVC

2 years

S-30

rappaport

3 spare ear-tips of di�erent sizes

3 bell type chest pieces2 spare transparent plastic diaphragms

reliable chrome-plated

dual tubing ensuresexcellent acoustic sensitivity

2 years

FreiCare Swiss AGSeepark 6CH - 9422 Staad SGPhone: + 41 71 855 07 [email protected]

FreiCare USA, LLC4000 Hollywood Blvdsuite 555-SouthHollywood, FL 33021, USAPhone: [email protected]

REF №DFDB002_EN_230419

MEDICAL DEVICESPRODUCT CATALOGUE 2019