4
Process Analyzer Cloud Point Process Analyzer CPA-4 Network and Fieldbus communication ATEX, CSA, GOST certified Customized solutions ASTM D 2500 compliance

ASTM D 2500 compliance Customized solutions ATEX, CSA, GOST … · 2014. 7. 16. · ATEX, CSA, GOST certified Customized solutions ASTM D 2500 compliance. Cloud Point Process Analyzer

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ASTM D 2500 compliance Customized solutions ATEX, CSA, GOST … · 2014. 7. 16. · ATEX, CSA, GOST certified Customized solutions ASTM D 2500 compliance. Cloud Point Process Analyzer

Process AnalyzerCloud Point Process Analyzer CPA-4

Network and Fieldbus communication

ATEX, CSA, GOST certified

Customized solutions

ASTM D 2500 compliance

Page 2: ASTM D 2500 compliance Customized solutions ATEX, CSA, GOST … · 2014. 7. 16. · ATEX, CSA, GOST certified Customized solutions ASTM D 2500 compliance. Cloud Point Process Analyzer

Cloud Point Process Analyzer CPA-4

Application

The BARTEC BENKE Cloud Point Process Analyzer (CPA-4) is a system for the fully automaticdetermination of the cloud point (CP) of transparent mineral oil products. The CPA-4operates online. It serves to monitor/maintain product quality for the in-spec productionof mixtures such as diesel fuel and heating oil.

YOUR competent

p a r t n e r f o r

s a f e p l a n t s

T h e s p e c i a l i s t s

f r o m B A R T E C

B E N K E h a v e

m a n y y e a r s

of exper ience in

p l a n t s a f e t y .

T h e y c r e a t e

so lu t ions wh ich

you can rely on:

e c o n o m i c a l ,

r e l i a b l e a n d

f o r t h e f u t u r e .

Special Features

Rugged design of measuring cell

Optimized assembly – easy removal of complete cell

Available communication interfaces:

- Modbus/RTU, Modbus/TCP

- Remote Access via modem, ISDN, LAN, VPN

Failure diagnosis and self monitoring

Additional cooling for the control unit housing if required

Multi-stream capability

Product specific parameter-sets

Make your decision for a strong partner!

Choose BARTEC BENKE also for

- Fast Loop Systems

- Sample Conditioning Systems

- Validation Systems

- Recovery Systems

- Chillers

- Air Conditioning Systems/HVAC

- Pre Commissioned Analyzer Shelters/Turn-Key Solutions

Page 3: ASTM D 2500 compliance Customized solutions ATEX, CSA, GOST … · 2014. 7. 16. · ATEX, CSA, GOST certified Customized solutions ASTM D 2500 compliance. Cloud Point Process Analyzer

O i l a n d G a s R e f i n e r i e s P e t r o c h e m i s t r y C h e m i s t r y

Norms and Standards

ASTM D 2500

DIN EN 23015

ISO 3015

IP 219

These norms and standards set theoperat ing l imits for cloud pointmeasurement for mineral oil products whichare clear at a path length of 40 mm (for IPand ASTM 1 ½ " = 38 mm) and have a cloudpoint below 49 °C (120 °F).

Method

The product sample is cooled under specified conditionsand its turbidity is observed. The temperature at which acloud of paraffin crystals first appears, is measured asthe CP. The CPA-4 uses a photometric measurementprinciple.

Note: Illustrations of this brochure show a typical CPA-4Analyzer with the optional application specific chiller.

Page 4: ASTM D 2500 compliance Customized solutions ATEX, CSA, GOST … · 2014. 7. 16. · ATEX, CSA, GOST certified Customized solutions ASTM D 2500 compliance. Cloud Point Process Analyzer

BARTEC BENKE GmbHGermany

Borsigstraße 1021465 Reinbek/Hamburg

Phone: +49 40 72703-0Fax: +49 40 72703-228

[email protected]

UK-D

-BBS

0805

08-0

6/20

12-B

ARTE

CW

erbe

Agen

tur-

2853

96

Technical dataMethod ASTM D 2500, DIN EN 23015,

ISO 3015, IP 219Measuring range -35 to +30 °C (-31 to 86 °F)

(limited within a range of 30K)others on request

Repeatability ≤ DIN EN/ASTMReproducibility ≤ DIN EN/ASTMMeasuring cycle discontinuous

(according to standard procedure)cycle time 4 to 8 min

Product streams 1 x sample, 1 x validation(additional on request)

Electrical dataNominal voltage AC 230 V ± 10 %, 1 phase; 50 Hz

other rating on requestMaximum power approx. 600 WconsumptionProtection class IP 54

Ambient conditionsAmbient temperature operation 5 to 40 °C (41 to 104 °F)Ambient humidity operation 5 to 80 % relative humidity,

non-corrosiveSampleQuality liquid (≤ 50 cSt), cooled,

filtered (≤ 10 µm),dry (moisture content max. 2000 ppm)

Consumption 20 to 40 l/hPressure at inlet 1 to 3 barTemperature at inlet at least 15 K above expected CPOutlet/Vent open to atmosphere

Utilities Instrument airConsumption min. 1.4 Nm³ per flushing cycle during

start-up (7 x housing volume)~ 0.8 Nm³/h in normal operating modeonly for leak compensation

Pressure at inlet 2 to 5 barQuality dew point ≤ -40 °C (-40 °F)

humidity class 2 or betteraccording to ISO8573.1

CoolantConsumption 20 to 60 l/hTemperature set point depending on measuring point:

-5 to +50 °C (23 to 122 °F)(general: water temperature= expected CP +30 K)

Pressure at inlet 1 to 3 barQuality clean cold water, free from particles

Signal outputs and inputsAnalog outputs CPA, see optionsDigital outputs sum alarm, ready signal, see optionsDigital inputs reset, see options

Electrical data of signal outputs and inputsAnalog outputs 4 to 20 mA 800 Ω out;

active isolated on requestDigital outputs DC 24 V; max. 0.5 ADigital inputs high DC 15 to 28 V

low DC 0 to 4 VAuxiliary power DC 24 V; max. 0.8 Asupply output

Control unitCentral control unit Industrial PC

Operating system Windows XP®

Control software PACS

User interfacesDisplay TFT display with touch function

800 x 600 pixelKeyboard virtual keyboard, controlled via

TFT display with touch function

Connections

Pipe fittings Swagelok® 6 mm/12 mmother fittings on request

Weight and dimensionsWeight approx. 250 kgDimensions (W x H x D) approx. 1140 x 1900 x 710 mm

Optional signal outputs and inputsDigital outputs identification of a validation cycle

identification of a product(4 parameter set available)valve for washing

Digital inputs product selectionrequest for a validation cycle

MODBUS interface MODBUS/RTU via RS485 or RS422or fiber optic cableMODBUS/TCP via fiber optic cable

Remote access via modem, ISDN,Ethernet via fiber optical or VPN

Important notice CPA-4 is subject to continuous product improvement, specifications are preliminary and may be subject to change without notice.

Cloud Point Process Analyzer CPA-4

Explosion protectionEx protection type II 2G EEx pd IIB T4 or(Europe) optional II 2G EEx pd IIB+H2 T4

Protection type depending on applicationCertification TÜV 02 ATEX 1846Optional available Class I, Div. 2, Groups B, C and Dclassification Class I, Zone 1, Groups IIB or IIB+H2(USA and CAN) Protection type depending on applicationCSA certificate no. 1524800