Auditory Hazard Units as an Index Auditory Hazard Units as an Index of Risk from Intense Sounds of Risk from Intense Sounds G. Richard Price US Army Research Laboratory and AHAnalysis Presented at the Third National Occupational Research Agenda (NORA) Hearing Loss Team Best Practice Workshop Cincinnati, Ohio May 8, 2003

Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Embed Size (px)

Citation preview

Page 1: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Auditory Hazard Units as an Index Auditory Hazard Units as an Index of Risk from Intense Soundsof Risk from Intense Sounds

G. Richard PriceUS Army Research Laboratory

and

AHAnalysis

Presented at the ThirdNational Occupational Research Agenda

(NORA) Hearing Loss Team Best Practice Workshop

Cincinnati, OhioMay 8, 2003

Page 2: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

The Impulse Noise ProblemThe Impulse Noise Problem

• A long history• Baffling data with traditional measures, e.g.

– If A-weighted energy is used:• 2000 - 3000 J/M2 measured under a muff found

acceptable for cannon impulses.• Implies that 2000+ rounds unprotected exposure from a

rifle would be safe• In fact, fewer than 10 rounds are hazardous

Page 3: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Consider Peak Pressure and DurationConsider Peak Pressure and Duration

-6000

-4000

-2000

0

2000

4000

6000

8000

0 20 40 60 80 100 120

TIME IN MSEC

PRES

SUR

E IN

PA

SCA

LS

100 SAFE

6 HAZARDOUS

Page 4: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Our approach to the problemOur approach to the problem• Try to understand the ear’s behavior at high level’s of

simulation,• Then devise a measure that was critically related.• The ear’s response is complex

– Several non-linearities– Simple graphic approach won’t work.

• A mathematical model of the ear created to deal with the complexity – the Auditory Hazard Assessment Algorithm for Human (AHAAH)

• A new unit of hazard produced:

Page 5: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

The Auditory Hazard Unit (AHU)The Auditory Hazard Unit (AHU)

• Defined within cochlea (site of damage) as:– Peak upward deflection of the basilar

membrane– In microns– Squared– Summed at a location

AHU = Sum (of peaks in microns2)• Is an output of AHAAH

Page 6: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Insights Embodied in AHAAH Insights Embodied in AHAAH

• Primary site of damage is the organ of Corti. • Loss mechanism is mechanical at high SPLs

and becomes linear in time.• External and middle ears shape the flow of

energy:– A band-pass filter.– Middle ear muscles, when contracting,

attenuate by stiffening the middle ear.

Page 7: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Basic Research Insights Embodied in Basic Research Insights Embodied in AHAAHAHAAH (continued)(continued)

– Annular ligament limits middle ear displacements - strongly peak clips at very high pressures.

• Mammalian ears are similar; hence fundamental loss processes will be as well.

• Accurate prediction is the goal:– Under-prediction results in hearing loss– Over-prediction results in unnecessary

restrictions and ineffective systems

Page 8: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

AHAA DevelopedAHAA Developed

Outer EarInner Ear

Middle Ear

area

Ue

Pe Lh RhCb

LdsCds

Rds

Eardrumconductive part

Ldm Cdc Rdc 1:Nt

Cm

Diffractionsoundfield

AirPlug

ConchaEarcanal

Li Ls Cal Ral LvCochleaIncus Stapes

Annularligament

VestibularVolume

Uc

Lo

RoRcPc

HelicotremaRoundwindow

Incudo-stapedal

joint

Malteo-Incudal

joint

Leverand area

ratio

Eardrumindependent

partBulla

Rmi

Cmi Cis

Ris Crw

Rdf

Ldf

2P P

Lpl

Rpl L1 L2 L3

A1 A2 A3

length

Page 9: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Creation of AHAACreation of AHAA• Created first for the cat ear – allowed real ears to be

tested with damaging stimulation• Electrophysiological measures of hearing used• Wide range of conditions tested

– Primer impulses– M-16 rifle impulses– Airbags– SPLs from 135 to 172 dB peak– 1 to 50 impulses

• Predictions of AHAA compared with effects

Page 10: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Prediction of Threshold ShiftPrediction of Threshold ShiftVALIDATION OF CAT EAR MODEL

y = 26.607Ln(x) - 140.08R2 = 0.8912

0

10

20

30

40

50

60

70

80

100 1000 10000AUDITORY DAMAGE UNITS

CTS

R = 0.94

Page 11: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Correlation with hair cell lossCorrelation with hair cell loss

0

10

20

30

40

50

60

70

80

0.51248163264

FREQUENCY/PLACE

PTS

0102030405060708090

100

% IH

C L

OSS

PTSMODELIHC

Page 12: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

CTSCTS--PTS RelationshipPTS Relationship

RECOVERY AT 4.0 KHZ

-10

0

10

20

30

40

50

60

70

80

90

0 10 20 30 40 50 60 70 80 90

CTS

PTS

R= 0.76

SLOPE= 0.86

Page 13: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

For Cat Model:For Cat Model:

• Predicts:– CTS– PTS– Hair cell loss

• For wide range of stimuli• Model ready for transformation into human

form

Page 14: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Creation of the Human VersionCreation of the Human Version

• Variables changed to human values• Adjusted to get conductive path correct• Stapes to basilar membrane transfer set to be similar

to cat in mid-range of sensitivity• Note: no hearing loss data used at this point (1997)• Expectation:

– Try to predict hearing loss data– Adjust as necessary

• In fact, no adjustment has been necessary

Page 15: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Transfer function Transfer function –– FF to Ear Drum FF to Ear Drum

Page 16: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Transfer function: ED to StapesTransfer function: ED to Stapes

MIDDLE EAR MUSCLES

Page 17: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

FF to Stapes, AFF to Stapes, A--WeightingWeighting

A-WEIGHTING

FF TO STAPES

MIDDLE EAR MUSCLES

Page 18: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

But does AHAAH predict hazard?But does AHAAH predict hazard?

• Compare AHUs from waveforms from human exposures with resulting changes in hearing

• Data sets available:– Albuquerque data– Small arms studies– Spark gap discharges– 120 mm mortar– Some clinical data

Page 19: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

The Albuquerque DataThe Albuquerque Data

• Large caliber fire simulated with explosive charges• 3 types of free field impulse

– At 7 levels (3 dB steps)– For 6,12, 25, 50 or 100 impulses– 178 dB to 194dB peak

• A reverberant impulse (at 7 levels, 1,2,3 rds)• 2 HPDs• In all, 53 conditions with 60 Ss per condition

Page 20: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Hazard is predicted when:Hazard is predicted when:

• For AHAAH: >500 AHUs (sum during exposure)

• For A-weighted energy: >8.7 J/m2 (total during exposure)

• For MIL-STD 1474: Peak pressure/duration exceeds limits on chart

Page 21: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

How do we define How do we define ““successsuccess”” in a in a prediction ?prediction ?

• Hazard for an ear = >25dB TS at any frequency• To be 95% sure that 95%ile case has been reached,

for n= 60, must have 6 or more “failures”, i.e. >5 failures = hazardous condition

• Or, if failure is predicted, can’t say it was not hazardous if a least one failure occurs.

• For 2 to 5 cases, just can’t be 95% certain.• Rule(s) applied to predictions by MIL-Std 1474, A-

weighted energy and AHAAH.

Page 22: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Evaluation DiagramEvaluation Diagram

OUTCOME SAFE HAZARDOUS

P

RED

ICTI

ON

H

AZAR

DO

US

SA

FE CORRECT RATING

CORRECT RATING

OVER-ESTIMATELESS EFFECTIVE WEAPONSMISSION ENDANGEREDEXCESS CASUALTIES

UNDER-ESTIMATEAUDITORY CASUALTIESPOORER COMMOMISSION ENDANGERED

Page 23: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

EVALUATION BY MIL STD-1474

OUTCOME SAFE HAZARDOUS

01 T1 T2F1 F2 F3G1 G2 G3R1 R2

O2 O3 O4 O5 O5 O7 O8 O9 OF OHT3 T4 T5 T6 T7 T8 T9 TF THF4 F5 F6 F7 F8 F9 FF FHG4 G5 G6 G7 G8 G9 GF R9GH R3 R4 R5 R6 R7 R8

P

RED

ICTI

ON

H

AZAR

DO

US

SA

FE

Page 24: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

EVALUATION BASED ON A-WEIGHTED ENERGY

OUTCOME SAFE HAZARDOUS

G1 G2 G3R1

O1 O2 O3 O4 O5 O6 O7 O8 O9 OF OFT1 T2 T3 T4 T5 T6 T7 T8 T9 TF THF1 F2 F3 F4 F5 F6 F7 F8 FF FH F9R2 R3 R4 R5 R6 R7 R8 R9G4 G5 G6 G7 G8 G9 GF GH

P

RED

ICTI

ON

HA

ZAR

DO

US

SAFE

ERRORS OFTEN > 20 DB

Page 25: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

EVALUATION BY AHAAH OUTCOME SAFE HAZARDOUS

O1 O2 O3 O4 O5 O6 O7 O8 T1 T2 T3 T4 T5 T6 T7 T8 F1 F2 F3 F4 F5 F6 F7 F8 G1 G2 G3 G4 G5 G6 G7 G8 G9 R1 R2 R3 R4 R5 R6 R7 R8 GF GH R9 O9 OF OH T9 TF TH F9 FF FH

P

RE

DIC

TIO

N

H

AZA

RD

OU

S

SA

FE

Page 26: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Exposure to other impulsesExposure to other impulses

• Need good waveform for AHAAH analysis or A-weighted energy measure

• Data reported vary with study – AHAAH can calculate equivalent data for comparison

• Keep criterion of 25 dB threshold shift at any frequency as hazardous.

Page 27: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Summary of AHAAH PredictionsSummary of AHAAH Predictions• 7.62mm, 50rds at 155dB - correct• 7.62mm, 25rds at 155dB - correct• 7.62mm, 25rds at 158dB - correct• FNC 6 rounds at 156dB - correct• FNC 5 rounds at 156dB - correct• G3 5 rounds at 159dB- correct• LAW 1 round - correct on 5 different exposures• Spark Gap impulses - correct on 4 predictions• AT4, 1 round, correct• 120 mm Mortar, 7 rounds, protected ears, correct

Page 28: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

In summaryIn summary

• AHAAH: 95% accuracy over all• MIL STD 1474: 38% accuracy (protected

ears)• A-weighted energy: 30% accuracy over all• AHAAH model works well

– All types of impulses– Protected ears– Unprotected ears

Page 29: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Why does AHAAH work so well in Why does AHAAH work so well in comparison to other methods?comparison to other methods?

• At lower pressures, the normal transmission path dominates and the model reproduces it. (Similar to A-weighting).

• It accounts for middle ear muscle attenuation• Most important: at higher pressures, non-linear

middle ear correctly limits energy entering cochlea.• Given a non-linear middle ear, linear systems, if

correct at one pressure/frequency regime, must be wrong elsewhere.

Page 30: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Functional issues: Accounting for Functional issues: Accounting for hearing protectionhearing protection

• Pressure waveforms measured under protector on a manikin at ear drum position or ear canal entrance can enter AHAAH at the right “place” and are properly evaluated.

• If a manikin is used, angular dependence of hazard is also correctly determined.

• Or effect of HPD can be calculated with digital filter or model – allows ‘de-rating’ to account for fit.

Page 31: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Operational issues Operational issues –– How it worksHow it works

• Runs on a PC – short analysis time.• Uses WINDOWS conventions• Program includes tools for importing, editing,

analyzing and printing waveforms.• Operates on a digitized waveform.• Outputs hazard in AHUs and • Makes a movie of the action within the

cochlea (allows engineering insight)

Page 32: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

““OfficialOfficial”” Status of ModelStatus of Model

• Peer reviewed at request of U.S. Army Medical Research and Development Command by the American Institute of Biological Sciences

Page 33: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

AIBS Peer Review Affirmed: AIBS Peer Review Affirmed: “ The Panel recommends that free-field pressure traces should be input to the model ---------------- and that personnel be allowed to be exposed to combinations of noise that does not result in more than 500 ADUs per day. The Panel feels that it was satisfactorily demonstrated that this limitation would produce 95/95 protection –that is, there is 95% confidence that 95% of the population willexperience temporary threshold shift (TTS) that is less than 25 dB. The Panel feels that the process can be applied to all impulse noise conditions, including those whose pressure-time histories appear to be quite different from the ones collected in the Albuquerque study, and still provide the same protection. Finally, the Panel feels that this criterion will provide adequate protection against unacceptable auditory damage over the soldier’s occupational lifetime, as long as the devices are worn and properly fit.”

Page 34: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

““OfficialOfficial”” status of modelstatus of model• Successfully peer reviewed by AIBS• Used internationally by SAE as basis for evaluation of

noise of airbag deployment• Being proposed to Army’s Surgeon General by

USACHPPM as basis for impulse noise hazard rating (first ever!).

• In draft ANSI standard – (legacy of Dan Johnson) • Used by NOISH, SAIC, DEBAKOM• Will be available, with documentation, on ARL

website

Page 35: Auditory Hazard Units as an Index of Risk from Intense Sounds · • 7.62mm, 50rds at 155dB - correct • 7.62mm, 25rds at 155dB ... • G3 5 rounds at 159dB- correct • LAW 1 round

Thank you for your attention!Thank you for your attention!