62
UM_Auriga_v1.4_012120 Auriga Server Motherboard User's Manual

Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

UM_Auriga_v1.4_012120

AurigaServer Motherboard

User's Manual

Page 2: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

Content

Table of Contents內內Preface ��������������������������������������������������������������������������������������������������������� iSafety Instructions �������������������������������������������������������������������������������������� iiAbout This Manual �������������������������������������������������������������������������������������� iii

Chapter 1� Product Features ����������������������������������������������������������������������11�1 Component ���������������������������������������������������������������������������������������11.2 Specifications �����������������������������������������������������������������������������������21�3 Feature ���������������������������������������������������������������������������������������������3

Chapter 2� Hardware Setup ������������������������������������������������������������������������42�1 Central Processing Unit Setup ����������������������������������������������������������4

2.1.1 Processor Installation ........................................................................................42�2 System Memory Setup ����������������������������������������������������������������������7

2.2.1 DIMM Installation ...............................................................................................7

2.2.2 DIMM Location ...................................................................................................8

2.2.3 DIMM Slot Installation .......................................................................................8Chapter 3� Motherboard Settings ���������������������������������������������������������������9

3�1 Block Diagram ����������������������������������������������������������������������������������93�2 Content List ������������������������������������������������������������������������������������103�3 Connector and Jumper Location �����������������������������������������������������113�4 Connector and Jumper ��������������������������������������������������������������������123�5 System LED Indicator ����������������������������������������������������������������������15

3.5.1 Rear Panel LED ............................................................................................... 15

3.5.2 Internal LED ..................................................................................................... 15

3.5.3 Internal LED Indicator Location ...................................................................... 16Chapter 4. BIOS Configuration Settings ���������������������������������������������������17

4�1 Navigation Keys ������������������������������������������������������������������������������174�2 BIOS Setup �������������������������������������������������������������������������������������18

4.2.1 BIOS Menu ....................................................................................................... 18

4.2.2 BIOS Basic Utility ............................................................................................. 18

4.2.3 BIOS Update ..................................................................................................... 214�3 Main ����������������������������������������������������������������������������������������������23

4.3.1 Main .................................................................................................................. 234�4 AMD CBS ����������������������������������������������������������������������������������������24

4.4.1 Zen Common Options ...................................................................................... 24

4.4.2 DF Common Options ....................................................................................... 25

4.4.3 UMC Common Options .................................................................................... 25

4.4.4 NBIO Common Options ................................................................................... 28

4.4.5 FCH Common Options ..................................................................................... 28

Page 3: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

4�5 Advanced ���������������������������������������������������������������������������������������294.5.1 Demo Board ..................................................................................................... 29

4.5.2 USB Configuration ........................................................................................... 29

4.5.3 CPU Related Setting ........................................................................................ 30

4.5.4 PCI Sub System Setting ................................................................................. 30

4.5.5 Memory Information ........................................................................................ 30

4.5.6 SIO AST2500 .................................................................................................... 30

4.5.7 H2O IPMI Configuration .................................................................................. 30

4.5.8 H2O Event Log Config Manager ...................................................................... 31

4.5.9 Console Redirection ........................................................................................ 32

4.5.10 H2oUve Configuration ................................................................................... 324�6 Security ������������������������������������������������������������������������������������������33

4.6.1 Current TPM Device ......................................................................................... 33

4.6.2 TrEE Protocol Version ...................................................................................... 33

4.6.3 TPM Availability ............................................................................................... 33

4.6.4 TPM Operation ................................................................................................. 334�7 Power ���������������������������������������������������������������������������������������������34

4.7.1 Auto Wake on S5 .............................................................................................. 344�8 Boot ������������������������������������������������������������������������������������������������354�9 Exit �������������������������������������������������������������������������������������������������36

Chapter 5. BMC Configuration Settings ����������������������������������������������������375�1 Login ����������������������������������������������������������������������������������������������375�2 Web GUI ������������������������������������������������������������������������������������������38

5.2.1 Menu Bar .......................................................................................................... 38

5.2.2 User Information and Quick Button ............................................................... 39

5.2.3 Dashboard ........................................................................................................ 40

5.2.4 Sensor .............................................................................................................. 40

5.2.5 FRU Information ............................................................................................... 41

5.2.6 Logs and Report .............................................................................................. 42

5.2.7 Settings ............................................................................................................ 43

5.2.8 Remote Control ................................................................................................ 45

5.2.9 Power Control .................................................................................................. 50

5.2.10 Maintenance .................................................................................................. 51

5.2.11 Sign out .......................................................................................................... 53Chapter 6� Technical Support �������������������������������������������������������������������54

Content

Page 4: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

Document Release History

Release Date Version Update Content October2018 1 User's Manual release to public.

March2019 1.1

1. BMC update

2. H/W spec updateApril2019 1.2 H/W update

May2019 1.3 S/W update

Auriga2020 1.4 S/W update

Page 5: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

Copyright © 2018 AIC, Inc. All Rights Reserved.

This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements.

Page 6: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

Copyright

No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photo-static, recording or otherwise, without the prior written consent of the manufacturer.

Trademarks

All products and trade names used in this document are trademarks or registered trademarks of their respective holders.

Changes

The material in this document is for information purposes only and is subject to change without notice.

Warning

1. A shielded-type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception. It is essential that only the supplied power cord be used.

2. Use only shielded cables to connect I/O devices to this equipment.3. You are cautioned that changes or modifications not expressly approved by the

party responsible for compliance could void your authority to operate the equipment.

Disclaimer

AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither AIC or its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice.

Instruction Symbols

Special attention should be given to the instruction symbols below.

NOTE This symbol indicates that there is an explanatory or supplementary instruction.

CAUTION This symbol denotes possible hardware impairment. Upmost precaution must be taken to prevent serious harware damage.

WARNINGThis symbol serves as a warning alert for potential body injury. The user may suffer possible injury from disregard or lack of attention.

Preface

i

Page 7: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

ii

When installing, operating, or performing maintenance on this equipment, the following safety precautions should always be taken into account in order to reduce the risk of fire, electric shock, and personal injury.

Carefully read the safety instructions below before using this product.

• Observe all of the warning and instruction signs distinctively marked on the product.

• Before performing system installations, please consult the User’s Manual provided with this product.

• Do not place this product on an uneven or weak surface (unstable cart, stand, table, ect.) that might induce the product to fall and sustain serious damage.

• Install only the equipment or device identified in the User’s Manual. Deploying other equipment or device with this motherboard could invoke improper connection of circuitry that leads to fire or personal injury.

• This product should only be operated with the type of power source indicated on the marked label. If you are questionable about which type of power supply is used in your area, consult your dealer or local Power Company.

• Disconnect the power supply module before removing power from the system.

• Unplug this product from the wall outlet before cleaning. Use a damp cloth for cleaning. Do not use liquid cleaners or aerosol cleaners.

• Do not use this product near a water source, including faucet and lavatory.

• Never spill liquids of any kind on this product.

• Never shove objects of any kind into this product’s open slots, as they may touch dangerous voltage points or short out parts and could result in fire or electric shock.

• Do not block or cover slots and openings in this unit, as they were made for ventilation and prevent this unit from overheating. Do not place this product in a built-in installation unless proper ventilation is available.

• Do not disassemble this product. This product should only be taken apart by trained personnel. Opening or removing covers and circuit boards may expose you to electric shock or other risks. Incorrect reassembly can also cause electric shock when the unit is subsequently used.

• Risk of explosion is possible if battery is replaced with an incompatible type. Dispose of used batteries accordingly.

• This product is equipped with a three-wire grounding type plug, a plug with a third (grounding) pin. As a safety feature, this plug is intended to fit only into a grounding type power outlet. If you are unable to insert the plug into the outlet, contact your electrician to replace the outlet. Do not remove the grounding type plug or use a 3-Prong To 2-Prong Adapter to circumvent the safety feature; doing so may result in electric shock and/or damage to this product.

Safety Instructions

Page 8: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

iii

Thank you for selecting and purchasing the Auriga Serverboard.This user's manual is provided for professional technicians to perform easy hardware setup, basic system configurations, and quick software startup. This document pellucidly presents a brief overview of the product design, device installation, and firmware settings for the Auriga motherboard. For the latest version of this user's manual, please refer to the AIC website: https://www.aicipc.com/en/productdetail/50929.

Chapter 1 Product FeaturesThis chapter delivers the overall layout of the product, including the fundamental components on the motherboard, design specifications, and noteworthy features. Auriga is an ideal server grade motherboard that is specifically designed to accommodate diverse enterprises for managing heavy workloads, databases, nearline applications, and cloud deployments. This product supports the single AMD EPYC™ 7000-series processor and Socket SP3 socket type with a memory support of 8 channel DDR4 RDIMM/LRDIMM/NVDIMM-N with EEC up to 2667 MHz.

Chapter 2 Hardware SetupThis chapter displays an easy installation guide for assembling the CPU (Central Processing Unit) and memory module. Utmost caution for proceeding to set up the hardware is highly advised. The components on the motherboard are highly fragile and vulnerable to exterior influence. Do not attempt to endanger the device by placing the device in a potentially unstable or hazardous surroundings, including positioning the device on an uneven grounds or humid environments.

Chapter 3 Motherboard SettingsThis chapter elaborates the overall layout of the server motherboard, including multifarious connectors, jumpers, and LED descriptions. These descriptions assist users to configure different settings and functions of the motherboard, as well as to confirm the location of each connector and jumper.

Chapter 4 BIOS Configuration SettingsThis chapter introduces the key features of BIOS, including the descriptions and option keys for diverse functions. These details provide users to effortlessly navigate and configure the input/output devices.

Chapter 5 BMC Configuration SettingsThis chapter illustrates the diverse functions of IPMI BMC, including the details on logging into the web page and assorted definitions. These descriptions are helpful in configuring various functions through Web GUI without entering the BIOS setup. For more information of BMC configurations, please refer to IPMI BMC (Aspeed2500) User's Manual for a more detailed description.

Chapter 6 Technical SupportFor more information or suggestion, please contact the nearest AIC corporation representative in your district or visit the AIC website: http://www.aicipc.com/tw/en. It is our greatest honor to provide the best service for our customers.

About This Manual

Page 9: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

1

Chapter 1. Product FeaturesAuriga User Manual

This section describes the hardware specifications and features of the Auriga motherboard. The fundamental components of the Auriga severboard are provided below.

1�1 Component

Auriga Serverboard

Product specifications and features are subject to change without prior notice.

Spica User ManualChapter 1� Product Features

Dimensions

mm : 431.8 x 157.4inches : 17 x 6.2

RJ45 for BMC Management

PCIe Gen4/Gen3 x16 Slot(16 Lanes of PCIe Gen4/Gen3)

COM Port By 3.5mm Phone Jack

VGA Port

2 x USB 2.0/3.0

2 x M.2 (22110 / Stack) Support SATA3/PCIe x1

3 x Slimline x4 (12 Lanes of PCIe Gen4/Gen3)

2 x SATA3

4 x Slimline x12 (48 Lanes of PCIe Gen4/Gen3)

4 x Slimline x4 (16 Lanes of PCIe Gen4/Gen3)

2 x USB 2.0/3.0

Socket SP3(Single AMD EPYC™ 7000-series Processor Supported)

8 x DDR4 DIMM Slots(1 DIMM/Channel)

PCIe Gen4/Gen3 x16 Slot(16 Lanes of PCIe Gen4/Gen3)

OCP Mezzanine V2.0(16 Lanes of PCIe Gen4/Gen3)

Page 10: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

2

Chapter 1. Product FeaturesAuriga User Manual

1.2 Specifications

System

Processor Support

Single AMD EPYC™ 7000-series(code-name: Naples; feature supports “Rome” CPU)

CPU TDP 180W

Socket Type Socket SP3

System Memory

• DDR4 2666/2400MHz RDIMM/LRDIMM (feature support up to DDR4 2933MHz by next gen. process upgrade)• Total 8 memory slots ; 8 channels• Supports up to 1TB• Supports NVDIMM feature

ExpansionSlots

• 4 x Slimline x12 + 7 x Slimline x4 • 2 x PCI Express Gen4/Gen3 x16 slots (Gen4 supported by Rome CPU)• 1 x OCP Mezzanine V2.0 supports PCI Express Gen4/Gen3 x16 (Gen4 supported by Rome CPU)Total support 124 lanes of PCI Express Gen4/Gen3(Gen4 supported by Rome CPU)• 2 x NGFF(M.2) M-Key(2242/2260/2280/22110) support SATA/PCIe x1

System BIOS

BIOS Type Insyde UEFI BIOS

BIOS Features

• ACPI• PXE• IPMI KCS interface• SMBIOS• SRIOV

• Serial console redirection• iSCSI• TPM• PCIe Hotplug

On-board Devices SATA/NVMe

• 2 x SATA 6.0 Gb/s • 2 x SATA 6.0 Gb/s by M.2 (M-key) supports up to 22110(optional - above 4 SATA ports can be replaced with 2 x PCIe x1 M.2)

On-board Devices

BMC

Aspeed AST2500 Advanced PCIe Graphics & Remote Management Processor• Baseboard Management Controller• Intelligent Platform Interface 2.0 (IPMI 2.0)• iKVM, Media Redirection, IPMI over LAN, Serial over LAN• HTML5

• SMASH Support

Graphics

Aspeed AST2500 Advanced PCIe Graphics & Remote Management Processor• PCIe VGA/2D Controller• 1920x1200@60Hz 32bpp

Input/Output

SATA/NVMe

• 2 x SATA 6.0 Gb/s • 2 x SATA 6.0 Gb/s by M.2 (M-key) supports up to 22110(optional - above 4 SATA ports can be replaced with 2 x PCIe x1 M.2)

LAN • 1 x GbE RJ45 dedicated to BMC management

USB• 2 x USB2.0/3.0 Type A connectors on rear I/O• 2 x USB2.0/3.0 by onboard vertical Type A connectors

VGA• 1 x external VGA port• 1 x internal VGA pin-header (share with external VGA port)

Serial Port• 1 x external COM port by 3.5mm phone jack• 1 x internal COM pin-header

Others • 1 x TPM 2.0 onboard

Page 11: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

3

Chapter 1. Product FeaturesAuriga User Manual

The Auriga server board integrates AMD EPYC™ 7000-series processor and 8 channel DDR4 memory slots to offer support for greater capacity, durability, and proficiency for our customers. Featuring the AMD EPYC™ 7000-series processor as the core design of the serverboard, which is emphasized for its outstanding performance, great memory bandwidth, and high security based on “Zen” microarchitecture, this product enhances these advantages by upgrading its system expansion.

In addition to integrating more memory capacity and system expansion to the server board, Auriga offers immediate and efficient management with Onboard Baseboard Management Controller and greater I/O extension. Featuring IPMI 2.0 and Aspeed AST2500 Advanced PCIe Graphics, the server board offers support for iKVM, Media Redirection, IPMI over LAN, Serial over LAN, HTML5, and Redfish.

• AMD EPYC™ 7000-series processor based on the AMD “Zen” microarchitecture for highest server performance

• 8 DDR4 DIMM slots for maximum memory performance

• One OCP Mezzanine V2.0 up to PCIe Gen4/Gen 3 (Gen 4 supported by Rome CPU) x16 extension

• Two PCIe Gen4/Gen3 x16 slots

• 4 slimline x12 + 7 slimline x4 connectors, total 76 PCIe Gen4/Gen3 lanes

• Onboard Baseboard Management Controller for system management and IPMI control

• Embedded components for 5+ year long life

• Rackmount Technology Extension (RTX) form fator utilizes full internal chassis volume for optimum I/O configurations

1�3 Feature

Page 12: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

4

Chapter 2. Hardware SetupAuriga User Manual

This section describes a simple instruction guide for installing the hardware components on the serverboard system. Turn off and unplug all system and peripheral devices before proceeding.

2�1 Central Processing Unit Setup The serverboard supports a single AMD EPYC™ 7000-series and socket type SP3.

2�1�1 Processor Installation

To ensure a safe and easy setup, you need to prepare before installation:

a T20 Torx screwdriver

ESD wrist strap/mat and conductive foam pad

CAUTIONThe pins of the processor socket are vulerable and easily susceptible to damage if fingers or any foreign objects are pressed against them. Please keep the socket pro-tective cover on when the processor is not installed.

CAUTIONWhen unpacking a processor, hold the processor only by its edges to avoid touching the contacts.

Procedure:Step 1 Remove the screw in the order designated in blue (the screw labeled 3→2→1)

as demonstrated in figure 1. After the screws are dislodged, the load plate will automatically be ejected as demonstrated in figure 2.

NOTEThe screws cannot be completely removed from the CPU cover.

Front

Figure 1 Figure 1 Dislodge screw Figure 2 Figure 2 Remove top cover

Chapter 2� Hardware Setup

3

Front

32

1Step 3

Step 1Step 2

Page 13: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

5

Chapter 2. Hardware SetupAuriga User Manual

Step 2 Lift the carrier frame by the blue metal tab and remove the protective cover as demonstrated in figure 3 and figure 4.

Step 3 Insert the CPU package into the carrier frame as demonstrated in figure 5.

Step 4 Remove the Pick and Place(PnP) cap by lifting the it upward as demonstrated in figure 6.

FrontFront

Front

Front

Figure 3Figure 3 Lift carrier frame Figure 4 Figure 4 Remove protective cover

Figure 5 Insert package

Figure 6 Lift PnP cap

Page 14: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

6

Chapter 2. Hardware SetupAuriga User Manual

Step 5 Close the carrier frame with the CPU package as demonstated in figure 7. Check if the frame is properly installed as demonstrated in figure 8.

Step 6 Close the load plate and fasten the screws in the order 1→2→3 to complete installation as demonstrated in figure 9.

Step 7 Apply thermal grease/paste on top of the CPU assembly.

Step 8 Secure the heatsink on top of the processor assembly to complete installation.

Front Front

Figure 7 Figure 7 Close carrier frame Figure 8 Figure 8 Verify installation

Figure 9 Figure 9 Close load plate

3

Front

32

1

Step 2

1Step 1

3Step 3

Page 15: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

7

Chapter 2. Hardware SetupAuriga User Manual

This server board supports 8 DIMM memory slots with 1 DIMM per channel.

2�2�1 DIMM Installation

Step 1 Unlock the DIMM socket by pressing the retaining clips outward.

Step 2 Insert the memory module into the slot. Make sure that the DIMM notch is

accurately positioned.

Step 3 Close the retaining clips to complete installation.

DIMM notch

2�2 System Memory Setup

Page 16: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

8

Chapter 2. Hardware SetupAuriga User Manual

2�2�2 DIMM LocationThe DIMMs are displayed on the Aurigaboard as JDMA0, JDMB0, JDMC0, JDMD0, JDME0, JDMF0, JDMG0, JDMH0 as demonstrated. JDMA0 and JDME0 are the located nearest to the CPU.

To ensure satisfactory performance, you need to:

Verify the DIMM type: This product supports DDR4 RDIMM/LRDIMM/NVDIMM-N with EEC(Error Correction Code).

Verify if all of the DIMMs installed are of the same DIMM type to avoid memory failure and loss of performance speed.

2�2�3 DIMM Slot Installation Populate the DIMM slots according to the corresponding Die as suggested to ensure a stable system performance.

Die #0: JDMC0 / JDMD0Die #1: JDMA0 / JDMB0Die #2: JDMG0 / JDMH0Die #3: JDME0 / JDMF0

A1

B1

A82

B82

A1

B1

A82

B82

10

2

1

23

41

5

1

16

2332

8

32 23

168

816

2332

32 23

168

32 23

168 8 16

2332

8

32

16

23

816

2332

3223

16 8

3223

16 8

3223

16 8816

322323

816

32

8

32

23

16

1

8

68 5857 1

543

1

1

3

5

2

1

20

19 1

2

+

+

+

+

+

+

+

10

40

20

30

40

10

30

20

40

10

30

20

13

3 1

1

4

8 16

3224

13

13

1

RPNMLKJHGFDDCBA

23

789

T

EC

B

C

BE

E

CB

21

1211

6

2

5

1

3

1

3

1

3

1

5

1

1

2

2

1

1

2

2

1

1 2

109

910

21

24

1 12

13

15

16

1

2

AA1AB1

GHJKLMNPRTUVW

1234567891011121314151617181920

Y

ABCDEF

2122

12

24 23

BBBCBD

AWAYBA

CYDADB

CBA

A1123 30

29

2825

26

27 555354

144143

79

287288

78

76

222

221 220

223

77

1

146

145

143144287288

222

79 223

1

77

221

78

76

220

146

145

145146

222

220

288

1

223

221

79

77

78

76

287 144

143

143144

287288

79 223

77

222221

78

76

220

146

1451

144143

79

77

78

76

1

287288

223

222

221 220

146

145

145146 1

79

77

222

221

78

76220

223

288

287 144

143

1146145

222

221

220

223 79

77

78

76

288

287 144

143

1

145146

222

221

220

223 79

77

78

76

288

287 144

143

13

12

7

18

6

1

13

7

18

6

1

19

19

11

19

1

9 11

11

9

119

11

191

9

119

911

B1

A1

B37

A37

B37

A37

B1

A1

B37

A37

B1

A1

B37

A37

B1A1

75

74

5767

25868

1

7

14

8 1

5

4

9

1

5

4

9

1

21

87

1

7

2

8

21

87 87

21

2 1

8 7

2 1

2 1

2 1

1 2

2

1

1

10

18

9 5

14

13

4

15 1394 2

1410 85 3

117

12 61

2 1

119120

19 20

1 2

8079

21

G

D S

G

D

S

G

D

S

G

D

S

G

D

S

G

D

S

G

D

S

G

D

S

D

S G

G

D

S

S

D

G

GD

S

D

GS

G

D

S

G S

D

G

D

S

D

GS

S

D

G

S

D

G

S

D

G

S

D

G

D

GS

G

D

S

G

D

S

G

D

S

GS

D

G

S

D

D

S G

G

SD

S

D

G

SG

D

D

SGSG

D

S G

D

A1K

A2

A2A1

K

A2K

A1

A2K

A1

A2

K

A1

A2K

A1

A2

K

A1

A1

KA2

K A2A1

A2 A1

K

A1

K

A2

A1K

A2

A1 K

A2

A1 KA2

A19

A1

B19

B1

A1

B1A19

B19

A1

B1

A19

B19

B1

A1

B19

A19

B19

A19

B1A1A1 B1

A19 B19

A19

B19

A1 B1

CPU0

JDM

A0JD

MB0

JDM

C0JD

MD0

Die #2 Die #1

Die #3 Die #0

JDM

H0

JDM

G0JD

MF0

JDM

E0

Page 17: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

9

Chapter 3. Motherboard SettingsAuriga User Manual

This section provides illustrations that display the internal jumpers, connectors, and system LED indicators on the Auriga motherboard. The motherboard layout and essential connectors are listed below for your reference.

3�1 Block Diagram

Chapter 3� Motherboard Settings

Page 18: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

10

Chapter 3. Motherboard SettingsAuriga User Manual

3�2 Content ListConnector/Jumper/Header Location Connector/Jumper/Header Location1a1b1c1d1e1f1g1h

PCIe Bus SAS slimline Connector

JG0FR1JG0FR2JG1FR1 JG1FR2JG2FL1JG2FL2JG3FL1JG3FL2

21 Battery Socket (For CR2032) JBAT1

2a2b2c2d

Fan Header

JFAN1JFAN2JFAN3 JFAN4

22 SOC CMOS Clear Header JCMOS1

3 HDT Connector JHDT123a23b

Standard PCIe slot x16 JPCIE1JPCIE2

4a4b

Remote Thermal Sensor Header

JTHM1JTHM2 24 BMC Debug Port Header JBMC_DP1

5 PMBUS I²C Header JPMBUS1 25 External USB2.0/3.0 x2 Connector JUSB1

6 Power Supply Connector JPWR1 26 Front VGA Header JVGA2

7a7b

Internal USB2.0/3.0Type-A Vertical Connector

JUSB2JUSB3 27 External VGA Connector JVGA1

8 DIMM Slot

JDMA0, JDMB0, JDMC0, JDMD0,JDME0, JDMF0, JDMG0, JDMH0

28 BMC Console Port JCONSOLE1

9 CPU Socket JCPU0 29a29b

BMC Console Port Select Header

J3J4

10 SOC UART Header JUART0 30 Front Plane Controller Header JLCM1

11a11b11c

PCIe Bus SAS slimline Connector

JP1R1JP1R2JP1R3 (Reserve)

31a31b NGFF(M.2) Connector JNGFF1

JNGFF2

12a12b

SATA DOM Power Header

JSATA1_PWR1JSATA2_PWR1

32a32b OCP Connecter JOCP1

JOCP2

13a13b

SATA DOM Power Header

JSATA1_PWR2 JSATA2_PWR2 33 RJ45 Connector JLAN1

14 BMC Reset Header JBMC_RST1 34 Chassis Intrusion Header JINTRUDER1

15a15b

SATA HDD Connector JSATA1 JSATA2 35 BMC Buzzer Header JBUZZER1

16 LPC Debug Port Header JLPC1 36 SSI Front panel Header JSSI117 Front I/O USB Header JUSB_INT1 37 IPMB_PMBus Header JBMC_I2C1

18 BMC Firmware ROM CS# Disable Header JBMC_DIS1 38 BMC COM2 Header JCOM1

19 BMC Firmware ROM Socket JBMC_ROM1 39 GPIO Header JBMC_GPIO1

20 System BIOS ROM Socket JSPI_BIOS1 40 Front panel Header for

Rack JRACK1

Page 19: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

11

Chapter 3. Motherboard SettingsAuriga User Manual

3�3 Connector and Jumper Location

A1

B1

A82

B82

A1

B1

A82

B82

10

2

1

23

41

5

1

16

2332

8

32 23

168

816

2332

32 23

168

32 23

168 8 16

2332

8

32

16

23

816

2332

3223

16 8

3223

16 8

3223

16 8816

322323

816

32

8

32

23

16

68 5857 1

543

1

1

3

5

2

1

20

19 1

2

+

+

+

+

+

+

+

10

40

20

30

40

10

30

20

40

10

30

20

13

3 1

1

4

8 16

3224

13

13

1

RPNMLKJHGFDDCBA

23

789

T

EC

B

C

BE

E

CB

21

1211

6

2

5

1

3

1

3

1

3

1

5

1

1

2

2

1

1

2

2

1

1 2

109

910

21

24

1 12

13

15

16

1

2

AA1AB1

GHJKLMNPRTUVW

1234567891011121314151617181920

Y

ABCDEF

2122

12

24 23

BBBCBD

AWAYBA

CYDADB

CBA

A1123 30

29

2825

26

27 555354

144143

79

287288

78

76

222

221 220

223

77

1

146

145

143144287288

222

79 223

1

77

221

78

76

220

146

145

145146

222

220

288

1

223

221

79

77

78

76

287 144

143

143144

287288

79 223

77

222221

78

76

220

146

1451

144143

79

77

78

76

1

287288

223

222

221 220

146

145

145146 1

79

77

222

221

78

76220

223

288

287 144

143

1146145

222

221

220

223 79

77

78

76

288

287 144

143

1

145146

222

221

220

223 79

77

78

76

288

287 144

143

13

12

7

18

6

1

13

7

18

6

1

19

19

11

19

1

9 11

11

9

119

11

191

9

119

911

B1

A1

B37

A37

B37

A37

B1

A1

B37

A37

B1

A1

B37

A37

B1A1

75

74

5767

25868

1

7

14

8 1

5

4

9

1

5

4

9

1

21

87

1

7

2

8

21

87 87

21

2 1

2 1

2 1

1 2

2

1

1

10

18

9 5

14

13

4

15 1394 2

1410 85 3

117

12 61

2 1

119120

19 20

1 2

8079

21

G

D S

G

D

S

G

D

S

G

D

S

G

D

S

G

D

S

G

D

S

G

D

S

D

S G

G

D

S

S

D

G

GD

S

D

GS

G

D

S

G S

D

G

D

S

D

GS

S

D

G

S

D

G

S

D

G

S

D

G

D

GS

G

D

S

G

D

S

G

D

S

GS

D

G

S

D

D

S G

G

SD

S

D

G

SG

D

D

SGSG

D

S G

D

A1K

A2

A2A1

K

A2K

A1

A2K

A1

A2

K

A1

A2K

A1

A2

K

A1

A1

KA2

K A2A1

A2 A1

K

A1

K

A2

A1K

A2

A1 K

A2

A1 KA2

A19

A1

B19

B1

A1

B1

A19

B19

A1

B1

A19

B19

B1

A1

B19

A19

B19

A19

B1A1A1 B1

A19 B19

A19

B19

A1 B1

1f

28 27 25

21

19

20

32a

1c

CPU0

13b

9

1b

33

23b

34

36

35

10

1g 1e 2a 2b 3 2c 2d 4a 1a

5

6

1d

8

11c

13a

11a

15a

11b

17

18

12b

14

12a

15b

23a

22

4b

24

29b

31a

32b

29a

31b

40

38

37

39

8

7b

7a

1h

16

30

26

Page 20: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

12

Chapter 3. Motherboard SettingsAuriga User Manual

2 a Fan Header (JFAN1)FANTACH_2 1 2 FANTACH_1+12V_S0 3 4 +12V_S0SYS1_FAN_PWM_C 5 6 SYS1_FAN_PWM_CGND 7 8 GND

2 b Fan Header (JFAN2)FANTACH_4 1 2 FANTACH_3+12V_S0 3 4 +12V_S0SYS2_FAN_PWM_C 5 6 SYS2_FAN_PWM_CGND 7 8 GND

2 c Fan Header (JFAN3)FANTACH_6 1 2 FANTACH_5+12V_S0 3 4 +12V_S0SYS3_FAN_PWM_C 5 6 SYS3_FAN_PWM_CGND 7 8 GND

2 d Fan Header (JFAN4) FANTACH_8 1 2 FANTACH_7+12V_S0 3 4 +12V_S0SYS4_FAN_PWM_C 5 6 SYS4_FAN_PWM_CGND 7 8 GND

4 a Remote Thermal Sensor Header (JTHM1)1 HM_TD4+2 HM_TD4-

4 b Remote Thermal Sensor Header (JTHM2)1 HM_TD2+2 HM_TD2-

5 PMBUS I²C Header (JPMBUS1 )1 SMB_PMBUS_CLK2 SMB_PMBUS_DATA3 PMBUS_ALERT_N4 GND5 +3V3_S5

6 Power Supply Connector (JPWR1)+12V_S0 8 1 GND+12V_S0 9 2 GND+12V_S0 10 3 GND +12V_S0 11 4 GND+12V_S0 12 5 GND +5V_STBY_PSU 13 6 GNDPS_OK_12V 14 7 PS_ON_12V_N

12 a SATA-DOM Power Header (JSATA1_PWR1 )1 +5V_S0_SATA12 GND

12 b SATA-DOM Power Header (JSATA2_PWR1 )1 +5V_S0_SATA22 GND

13 a SATA-DOM Power Header (JSATA1_PWR2 )1 GND2 DOM_PWR13 +5V_S0_SATA1

Jumper default Pin-1 & Pin-2

13 b SATA-DOM Power Header (JSATA2_PWR2 )1 GND2 DOM_PWR23 +5V_S0_SATA2

Jumper default Pin-1 & Pin-2

14 BMC Reset Header (JBMC_RST1)1 BMC_RESET

(BMC SRST#)2 GND

Jumper default OPEN

16 LPC Debug Port Header (JLPC1)LPC_HDR_CLK 2 1 GNDP0_LFRAME_N 4 3 P0_LDRQ0_NLPC_HDR_RST_N 6 5 P0_SERIRQP0_LAD3 8 7 P0_LAD2+3V3_S0 10 9 P0_LAD1P0_LAD0 12 11 GND

3�4 Connector and Jumper

Page 21: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

13

Chapter 3. Motherboard SettingsAuriga User Manual

17 Front I/O USB Header (JUSB_INT1)+5V_HUB2 1 2 +5V_HUB2USB2_HUB1_DN 3 4 USB2_HUB2_DNUSB2_HUB1_DP 5 6 USB2_HUB2_DPGND 7 8 GNDKEY (no pin) 9 10 GND

18 BMC Firmware ROM CS# Disable Header (JBMC_DIS1)1 FW_SPI_CS0_N2 GND

Default keep OPEN�

22 SOC CMOS Clear Header (JCMOS1)1 +VDDBT_RTC_JP

(CR2032)2 +1V5_RTC (SOC)3 GND

Jumper default Pin-1 & Pin-2

24 BMC Debug Port Header (JBMC_DP1)1 RS232_TXD52 RS232_RXD53 GND

26 Front VGA Header (JVGA2)DACROA 2 1 GNDNC 4 3 DACGOAGND 6 5 DDC_DATAODACBOA 8 7 GNDAHSYNCO 10 9 NCDVO_5V 12 11 AVSYNCOGND 14 13 GNDDDC_CLKO 16 15 GND

29 a BMC Console Port Select Header (J3)1 TX12 PJ_TX3 TX5

Jumper default Pin-1 & Pin-2

29 b BMC Console Port Select Header (J4)1 RX12 PJ_RX3 RX5

Jumper default Pin-1 & Pin-2

34 Chassis Intrusion Header (JINTRUDER1)1 CHASSIS_OPEN_N2 GND

35 BMC Buzzer Header (JBUZZER1)1 +5V_S02 BMC_BUZZER

36 SSI Front panel Header (JSSI1) FP_HDR_PWR_LED 1 2 FP_PWR (+3V3_S5)

KEY (no pin) 3 4 HDR_CHASSIS_ID_LED (+5V_S5)

FP_PWR_LED_L 5 6 ID_LED_OUT_NHDD_LED_P (+3V3_S5) 7 8 SYS_HEALTH2#

HDD_LED_N 9 10 SYS_HEALTH#FP_PWR_BTN_N 11 12 LAN1_ACTLED_PWRGND 13 14 PHY1_LED0_NSW_COLD_RST_N 15 16 BMC_I2C_08_SDAGND 17 18 BMC_I2C_08_SCLBMC_ID_IN_N 19 20 CHASSIS_OPENTEMP_SENSOR (NC) 21 22 LAN2_ACTLED_PWRFP_NMI_BTN_N 23 24 PHY1_LED1_R

37 IPMB_PMBus Header (JBMC_I2C1)1 BMC_I2C_01_SDA2 GND3 BMC_I2C_01_SCL4 NC

38 BMC COM2 Header (JCOM1)DCDB 2 1 DSRBRXDB 4 3 RTSBTXDB 6 5 CTSBDTRB 8 7 RIBGND 10 9 NC

39 GPIO Header (JBMC_GPIO1)RACK_EXTRST_N 2 1 GNDBMC_GPY1 4 3 BMC_I2C_09_SDABMC_GPY0 6 5 BMC_I2C_09_SCL

Page 22: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

14

Chapter 3. Motherboard SettingsAuriga User Manual

40 Front panel Header for RACK (JRACK1)RACK_EXTRST_N 1 2 BMC_I2C_08_SCLGND 3 4 BMC_I2C_08_SDABMC_I2C_01_SCL 5 6 GNDBMC_I2C_01_SDA 7 8 RACK_PWM0GND 9 10 RACK_TACH0RACK_PMBUS _CLK 11 12 GNDRACK_PMBUS _DATA 13 14 RACK_PWM1PMBUS_ALERT_N 15 16 RACK_TACH1RACK_CHASSIS_OPEN 17 18 RACK_GPIO_EXINGND 19 20 CHASSIS_1U2N_N

Page 23: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

15

Chapter 3. Motherboard SettingsAuriga User Manual

3�5�1 Rear Panel LED

Cable Link/Active Status:LAN1 (Right, JLAN1 Pin-13,14) Green 1. Cable Plug-In : Green

2. Cable Plug-Out : Off

Linking Speed:LAN1 (Left, JLAN1 Pin-15,16)

Green,Amber

1. 1Gbps : Green2. 100Mbps : Amber 3. 10Mbps & No connect: Off

3�5�2 Internal LED

LED1JSATA1 status LED(U2005 ASM1061)

ON (Blinking) Indicates SATA is in use when LED is lit.

OFF Indicates SATA is un-used when LED is dark.

LED2JSATA2 status LED(U2008 ASM1061)

ON (Blinking) Indicates SATA is in use when LED is lit.

OFF Indicates SATA is un-used when LED is dark.

LED3HEART BEAT

ON(Blinking) BMC activity is detected.ON BMC is not active.

LED6RSMRST LED

ON Resume Well Reset is ready.OFF Resume Well Reset is not ready.

LED7POWER GOOD LED

ON System power good is ready.OFF System power good is not ready.

LED4, LED9LAN Speed LED(JLAN1, 15, 16)

ONLAN Linking Speed : (1) 1Gbps : Green (LED9)(2) 100Mbps : Amber (LED4)

OFF (1) LAN Linking Speed 10Mbps(2) No connection

LED5LAN status LED(JLAN1,13,14)

ON (Blinking) LAN Cable Linking Status

OFF LAN* is not active and the LAN cable is not connected.

LED8UID LED

ON (Blinking) UID activity is detected.OFF UID activity is not detected.

3�5 System LED Indicator

Page 24: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

16

Chapter 3. Motherboard SettingsAuriga User Manual

3�5�3 Internal LED Indicator Location

Page 25: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

17

Chapter 4. BIOS Configuration SettingsAuriga User Manual

This chapter demonstrates how to configure the UEFI BIOS settings in your system device. You can enter the BIOS screen during system startup.

To enter BIOS configuration settings,• Press Esc key during the Power-On-Self-Test (POST)

To enter BIOS after POST, you have to restart the system by using one of the three methods:• Press Ctrl + Alt + Delete.• Press the reset button on the system chassis. • Turn the system off and on.

4�1 Navigation KeysThe navigation keys are listed below.

Function Key Description< >

< > < >< >

Select item.

< Enter > Select and enter sub-screen.

< + + > < - - > Modify selected option.

< F1 > General help.

< F2 > Previous Value.

< F3 > Optimized defaults.

< F4 > Save & Exit.

< F5> < F6 > Change values.

< F7 > Discard Change and Exit.

< F9 > Load Optimal Default for all values.

< F10 > Save changes and exit.

< F12 > Print Screen.

< Esc > Exit the current menu screen.

Chapter 4. BIOS Configuration Settings

Page 26: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

18

Chapter 4. BIOS Configuration SettingsAuriga User Manual

4�2�1 BIOS MenuPress and to select the options of the menu bar. Press Enter to access the option screen.

Menu Description

Main Displays system information such as CPU bus speed, system memory speed, total installed memory, current EFI language, and system date & time.

AMD CBS Displays AMD CBS Configurations.

Advanced Allows configuration of advanced system settings such as ACPI features, boot, and chipset configuration.

Security Sets passwords and security functions.

Power Configures Power Configurations.

Boot Sets boot options such as Quick Boot or USB Boot.

4�2�2 BIOS Basic Utility

Step 1 Press ESC to run the BIOS setup procedure.

4�2 BIOS Setup

Page 27: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

19

Chapter 4. BIOS Configuration SettingsAuriga User Manual

Step 2 There will be a message “Entering SETUP” displayed on the diagnostics screen.

Step 3 Identify the BIOS version.

Page 28: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

20

Chapter 4. BIOS Configuration SettingsAuriga User Manual

Step 4 Load Optimal Default Setting.

Step 5 Save the setting and exit the BIOS setup utility.

Page 29: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

21

Chapter 4. BIOS Configuration SettingsAuriga User Manual

4�2�3 BIOS UpdateTo identify the latest BIOS version, please check the BIOS setup.

Page 30: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

22

Chapter 4. BIOS Configuration SettingsAuriga User Manual

Update BIOS by INSYDE H2OFFT-D utility under DOS environmentIf you need to update Flash in the DOS environment, please use H2OFFT-D utility.To use this utility, you must include the flash.bat , H2OFFT-D.exe, and bin file in thesame folder. Please follow the instructions to update whole flash part:

Step 1 Execute flash.bat to update Flash in the DOS environment.

Step 2 Reboot the system.

Page 31: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

23

Chapter 4. BIOS Configuration SettingsAuriga User Manual

4�3�1 Main

Main Option Key:

Option Key Description

Language Configures the language used for your BIOS settings.System time Configures the current time.System date Configures the current date.

4�3 Main

Page 32: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

24

Chapter 4. BIOS Configuration SettingsAuriga User Manual

AMD CBS Option Key:

4�4�1 Zen Common Options

Zen Common OptionsCore Performance Boost Auto Disable

Global C-state Control Auto Enable Disable

Global C-state Control Min=0x1,Max=0x10

Core/Thread Enablement

Agree Downcore control

Two (1+1) Two (2+0)Three (3+0) Four (2+2)Four (4+0) Six (3+3)Auto

Disagree

Prefetcher Settings

L1 Stream HW Prefetcher Auto Enable Disable

L2 Stream HW Prefetcher Auto Enable Disable

4�4 AMD CBS

Page 33: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

25

Chapter 4. BIOS Configuration SettingsAuriga User Manual

4�4�2 DF Common Options

DF Common Options

Memory interleaving None Channel Die Socket Auto

Memory interleaving 256 512 1 2 Auto

4�4�3 UMC Common Options

UMC Common Options

DDR4 CommonOptions

DRAM Timing Configuration

I Decline

I Accept

OverclockAutoEnabled

Memory Clock Speed

Auto333 MHz400 MHz533 MHz667 MHz800 MHz933 MHz1050 MHz1066 MHz1067 MHz1200 MHz1333 MHz1467 MHz1600 MHz

Tcl tCL time.

TrcdrdTrcdwr

RAS# Active to CAS# read/write delay.

Trp The row precharge time.

Tras min RAS# active time

Trc CtrlAutoManual

Trc Min=0x1d, Max=0x87

TrrdSActivate Delay Time, different bank group

Page 34: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

26

Chapter 4. BIOS Configuration SettingsAuriga User Manual

DDR4 CommonOptions

DRAM Timing Configuration I Accept

TrrdLActivate Delay Time, same bank group

Tfaw CtrlAutoManual

Tfaw Min=0x6Max=0x36

TwtrS

Minimum Write to Read Time, different bank group

TwtrLMinimum Write to Read Time, same bank group

Twr CtrlAutoManual

Twr Min=0xa, Max=0x51

Trcpage CtrlAutoManual

Trcpage Min=0x0,Max=0x3ff

TrdrdScL CtrlAutoManual

TrdrdScL Min=0x1,Max=0xf

TwrwrScL CtrlAutoManual

TwrwrScL Min=0x1,Max=0x3f

Trfc CtrlAutoManual

Trfc Min=0x3c,Max=0x3de

Trfc2 CtrlAutoManual

Trfc2 Min=0x3c,Max=0x3d

Trfc4 CtrlAutoManual

Trfc4 Min=0x3c,Max=0x3d

Page 35: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

27

Chapter 4. BIOS Configuration SettingsAuriga User Manual

DDR4 CommonOptions

DRAM Timing Configuration I Accept

ProcODT Processor ODT

TcwlMinimum CAS Write Latency Range

Trtp Read to Precharge Delay

Trdwr tWRTTO time.

TwrrdRead delay when accessing different DIMMs.

TwrwrScTwrwrSdTwrwrDdTrdrdScTrdrdSdTrdrdDd

Write to iwrite timing same DIMM same chip select.

Tcke

CKE minimum high and low pulse width in memory clock cycles.

DDR4 CommonOptions

Common Ras ECC Configuration

DRAM ECC Symbol Size

x4x8Auto

DRAM ECC EnableAutoEnableDisable

Security

TSMEAutoEnableDisable

Data ScrambleAutoEnableDisable

DRAM Memory Mapping

Chip select Interleaving

AutoDisable

Bank GroupSwap

AutoEnableDisable

NVDIMM Read only.

Page 36: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

28

Chapter 4. BIOS Configuration SettingsAuriga User Manual

4�4�4 NBIO Common Options

NBIO Common OptionsDeterminism Slider Auto Power PerformancecTDP Control Auto Manual

NB Configuration IOMMUAuto

EnableDisable

4�4�5 FCH Common Options

FCH Common Options

AC Power Loss Options Ac Loss Control

Always off Always onReserved Previous

Page 37: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

29

Chapter 4. BIOS Configuration SettingsAuriga User Manual

Advanced Option Key:

4�5�1 Demo Board

Demo Board

OnBrd/Ext VGA Select Auto Onboard External

4�5�2 USB Configuration

USB ConfigurationUSB Ports Per-Port Disable Control Enable Disable

USB 3.0 Port 0USB 3.0 Port 1USB 2.0 Port 0USB 2.0 Port 1USB 3.0 Port 0USB 3.0 Port 1USB 2.0 Port 0USB 2.0 Port 1

Enable Disable

4�5 Advanced

Page 38: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

30

Chapter 4. BIOS Configuration SettingsAuriga User Manual

4�5�3 CPU Related Setting

CPU Related SettingSVM support Enable DisableSMM Code Lock Enable DisableAMD CPU SMT Support Auto DisableAMD CPU P-state Control Enable Disable

4�5�4 PCI Sub System Setting

PCI Sub System SettingAbove 4G resource decoding Enable DisablePCIe SR-IOV Enable DisablePCI NET Card UEFI OpROM Enable DisablePCI Storage Card UEFI OpROM Enable Disable

4�5�5 Memory Information

Memory InformationMemory DIMM information

4�5�6 SIO AST2500

SIO AST2500Serial Port ASerial Port B Auto Enable Disable

Base I/O Address 2E8 2F8 3E8 3F8Interrupt IRQ3/IQR9 IRQ4/IQR10

4.5.7 H2O IPMI Configuration

H2O IPMI ConfigurationIPMI Support Enable DisableBMC Warmup Time Min=0, Max=240ACPI SPMI Table Enable DisableBoot Option Support Enable DisableSet BIOS version to BMC Enable Disable

BMC Configuration

Watchdog Timer Support Enable Disable

Not disable in OS Enable DisableWatchdog Timer Timeout Min=2, Max=8

Watchdog Timer Action

No Action Hard ResetPower Down Power Cycle

Page 39: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

31

Chapter 4. BIOS Configuration SettingsAuriga User Manual

BMC Configuration

Power Cycle Time Support Enable Disable

Power Cycle Time Min=0, Max=255Power Button Enable DisableReset Button Enable DisableNMI Button Enable DisableLan Port Configuration Dedicated Shared

Lan Port Configuration Min=0, Max=0

IPv4 Source Static DHCPIPv6 Mode Enable DisableIPv6 Prefix Length Min=0, Max=255

SDR List SDR List Support Enable Disable

4.5.8 H2O Event Log Config Manager

H2O Event Log Config Manager

Configuration Pages

BIOS Event Log Configuration

Log Event To

ALLBIOSBMC SELMEMORYDisable

Event Log Full option

OverwriteClear AllStop Logging

POST Message Configuration

POST Message Configuration Enable Disable

Progress Code Enable DisableError Code Enable DisableDebug Code Enable DisableLog Post Message Enable Disable

Show Post Message Enable Disable

Serial Debug Message Configuration

Advanced Mode Enable Disable

EFI DEBUG Message Level

Default InformationError WarningVerbose Disable

Show Progress Code Serial Message

Enable Disable

Show Error Code Serial Message Enable Disable

Page 40: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

32

Chapter 4. BIOS Configuration SettingsAuriga User Manual

Configuration PagesSerial Debug Message Configuration

Show Debug Code Serial Message

Enable Disable

Event And Message Pages Read only.

4�5�9 Console Redirection

Console Redirection

Console Redirection Setup

Console Serial Redirect Enable Disable

Terminal Type VT_100 VT_100+ VT_UTF8 PC_ANSI

Baud Rate1200 2400 4800 960019200 38400 57600 115200

Data Bits 7 Bits 8 BitsParity None Even OddStop Bits 1 Bits 2 BitsFlow Control None RTS/CTS XON/XOFF

Information Wait Time

0 Second 2 Seconds 5 Seconds10 Seconds 30 Seconds

C.R. After Legacy Boot Yes No

Text Mode Resolution

AUTO Force 80x25 Force 80x24 (DEL FIRST ROW)

Force 80x24 (DEL LAST ROW) Limit 128x40

Auto Refresh Enable DisableAuto adjust Terminal resolution

Enable Disable

Console Redirection Device Setup

Port Enable Enable DisableUse GlobalSetting Enable Disable

Terminal Type VT_100 VT_100+ VT_UTF8 PC_ANSI

Baud Rate1200 2400 4800 960019200 38400 57600 115200

Data Bits 1 Bits 2 BitsParity None Even OddStop Bits 1 Bits 2 Bits

Flow ControlFlow Control NoneRTS/CTS XON/XOFF

4.5.10 H2oUve Configuration

Console Redirection

H2oUve Setup H2OUVE Support Enable Disable

Page 41: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

33

Chapter 4. BIOS Configuration SettingsAuriga User Manual

Security Option Key:

4�6�1 Current TPM Device

Current TPM DeviceNot detected TPM 2.0

4�6�2 TrEE Protocol Version

TrEE Protocol Version1.0 1.1

4�6�3 TPM Availability

TPM AvailabilityAvailable Hidden

4�6�4 TPM Operation

TPM OperationNo operation Enable Disable Change EPS

4�6 Security

Page 42: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

34

Chapter 4. BIOS Configuration SettingsAuriga User Manual

Disabled,By Every Day,By Day of Month

Power Option Key:

4�7�1 Auto Wake on S5

Auto Wake on S5Disable By Every Day By Day of Month

4�7 Power

Page 43: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

35

Chapter 4. BIOS Configuration SettingsAuriga User Manual

Boot Option Key:

BootBoot Type UEFI Boot Type Legacy Boot TypeQuick Boot Enable DisableQuiet boot Enable DisableNetwork Stack Enable DisablePXE Boot capability Enable Disable

Power Up in Standby Support Enable Disable

Add Boot Options First Last Auto

ACPI SelectionAcpi1.0B Acpi3.0 Acpi4.0Acpi5.0 Acpi6.0 Acpi6.1

USB Boot Enable DisableEFI Device First Enable DisableUEFI OS Fast Boot Enable DisableTimeout Min=0, Max=10Automatic Failover Enable Disable

4�8 Boot

Page 44: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

36

Chapter 4. BIOS Configuration SettingsAuriga User Manual

Exit Option Key:

Save and ExitExit Saving Changes Exit system setup and save your changes.Save Change Without Exit Save your changes without exiting the system.Exit Discarding Changes Discard your changes when existing the system.Load Optimal Defaults Load

Load Custom Defaults Resets the BIOS settings to the default values and overwrites any previously customized settings.

Save Custom Defaults Saves the cumostomized defaults in BIOS settings.Discard Changes Discard your changes.

4�9 Exit

Page 45: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

37

Chapter 5. BMC Configuration SettingsAuriga User Manual

This chapter displays the configuration settings of IPMI BMC in your system device.

5�1 Login

NOTEThis feature works with the html5. Please use a browser that supports html5.

The IP address below is an example using the default IP setting. The IP address is configurable.

Step 1 Open the browser and then type in the default BMC IP address: 172.200.20.199.

Step 2 Use the default user name and password for first-time BMC WEB GUI login. Users need to set authorization before sending a command. Change the tab to Aurthorization.

Type: DefaultAccount: adminPassword: admin

NOTE-The default user name and password are in lower-case characters.-Users who login with the root user name and password will have full administrative power. The root password can be changed after login.

Chapter 5. BMC Configuration Settings

Page 46: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

38

Chapter 5. BMC Configuration SettingsAuriga User Manual

5�2�1 Menu BarClick to select the options of the menu bar.

Menu Description

Dashboard The Dashboard page gives the overall information about the status of a device.

Sensor The Sensor Readings page displays all the sensor related information.

FRU Information The FRU Information page displays the details for FRU devices in the system.

Logs & Reports The Logs and Reports page monitors and reports on the status of IPMI event and video.

Settings The Settings page allows you to configure various basic settings, such as date & time, KMV Mouse, Services, and etc.

Remote Control The Remote Control page allows you to remotely manage server hardware components.

Image Redirection The Image Redirection page is used to configure the image into BMC for redirection.

Power Control The Power Control page allows you to view and control the power of your server.

Maintenance This group of pages allows you to do maintenance tasks on the device.

Sign out The Sign out page allows you to log out of the web GUI.

5�2 Web GUI

Page 47: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

39

Chapter 5. BMC Configuration SettingsAuriga User Manual

5�2�2 User Information and Quick Button The user information and quick access buttons are located at the top right corner. It displays the logged-in user, his/her privilege and the four quick buttons allowing you to perform different functions.

Button DescriptionUser Only valid commands are allowed.

Operator All BMC commands are allowed except for the configuration commands that can change the behavior of the out-of-hand interfaces.

Administrator All BMC commands are allowed.

No access Login access denied.

Notification Click to view notification messages.

Warning Click to view warning messages.

Sync Click to synchronize with the latest sensor and event log updates.

Refresh Click to reload the current page.

User-informSign out: Click to log out of the GUIProfile: Click to enter the User Management Configuration dialog box in figure xx.

Help Click to view more details on field descriptions.

Page 48: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

40

Chapter 5. BMC Configuration SettingsAuriga User Manual

5�2�3 DashboardThe Dashboard page displays device, system information, and assert logs.Click Dashboard on the menu bar to view the overall information of the server.

5�2�4 SensorThe Sensor page displays the status and records on related sensors. Click a record to view detailed information on a particular sensor.

Page 49: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

41

Chapter 5. BMC Configuration SettingsAuriga User Manual

5�2�5 FRU InformationThe FRU Information page displays Basic Information, Chassis Information, Board Information and Product Information of the FRU device. Click FRU Information on the menu bar to view the details of the selected device.

Page 50: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

42

Chapter 5. BMC Configuration SettingsAuriga User Manual

5�2�6 Logs and ReportThe System Inventory page displays IPMI Event Log and Video Log. Click Logs and Reports from the menu bar and select Event Log or Video Log to view the contents.

Event Log Page

Video Log Page

Page 51: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

43

Chapter 5. BMC Configuration SettingsAuriga User Manual

5�2�7 SettingsThe Settings page displays the configuration settings for Date & Time, External User Services, KVM Mouse Setting, Log Settings, Media Redirection Settings, Network Settings, PAM Order Settings, Platform Event Filter, Services, SMTP Settings, SSL Settings, System Firewall, User Management, and Video Recording.

Page 52: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

44

Chapter 5. BMC Configuration SettingsAuriga User Manual

Settings Menu and Option Key:

Settings DescriptionDate and Time

External User Services

LDAP/E-directory Settings Active directory Settings Radius Settings

General Settings

Role Groups

General Settings

Role Groups

General Radius Settings

Advanced Radius Settings

KVM Mouse Setting

Mouse Mode Configuration• Relative Positioning (Linux)• Absolute Positioning (Windows)• Other Mode (SLES-11 OS Installation)

Log Settings SEL Log Settings Policy Advanced Log SettingsMedia Redirection Settings General Settings VMedia Instance

SettingsActive Redirections Remote Session

Network Settings Network IP Settings

Network Bond Configuration

Network Link Configuration

DNSConfiguration

Sideband Interface(NC-SI)

PAM Order Settings PAM Authentication Order

Platform Event Filter Event Filters Alert Policies LAN Destinations

ServicesSMTP Settings SMTP SettingsSSL Settings View SSL certificate Generate SSL certificate Upload SSL certificate

System Firewall

Generate Firewall Settings

IP Address Firewall Rules Port Firewall Rules

Existing Firewall Settings

Add Firewall Settings

Existing IP Rules

Add New IP rule

Existing Port Rules

Add New Port Rule

User Management

Video Recording Auto Video Settings

Video Trigger Settings

Video Remote Settings

Pre-Event Video Recordings

Page 53: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

45

Chapter 5. BMC Configuration SettingsAuriga User Manual

5�2�8 Remote ControlThe Remote Control page displays the configuration for power control and remote KVM.

Click Java Console to start the JViewer video redirection.

Page 54: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

46

Chapter 5. BMC Configuration SettingsAuriga User Manual

Click Launch KVM to open the Remote KVM page.

Page 55: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

47

Chapter 5. BMC Configuration SettingsAuriga User Manual

Procedure to Start KVM

Step 1 Click Start KVM to start the H5Viewer video redirection.

Step 2 Click Browse to select CD Image.

Step 3 Click Start Media to redirect the selected CD image file to the Host.

Step 4 To stop the recording, click Stop Record.

Page 56: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

48

Chapter 5. BMC Configuration SettingsAuriga User Manual

Remote KVM Menu and Option Key:

Remote KVM DescriptionStart KVM Starts the H5Viewer video redirection.Stop KVM Stops the H5Viewer video redirection.

Video Record

Pause Video This option is used for pausing Console Redirection.

Resume Video This option is used to resume the Console Redirection when the session is paused.

Refresh Video This option can be used to update the display shown in the Console Redirection window.

Host Display

Display on If you disable this option, the display will be shown on the screen in Console Redirection.

Display off

If you enable this option, the server display will be blank but you can view the screen in Console Redirection. If you disable this option, the display will be back in the server screen.

Mouse

CaptureScreen

This option helps to take the screenshot of the host screen and save it in the client’s system.

Show ClientCursor

This menu item can be used to show or hide the local mouse cursor on the remote client system.

Mouse Mode

This option handles mouse emulation from local window to remote screen using either of the two methods. Only ‘Administrator’ has the right to configure this option.• Absolute mouse mode: The absolute position of the local

mouse is sent to the server if this option is selected.• Relative mouse mode: The Relative mode sends the

calculated relative mouse potion displacement to the server if this option is selected.

• Other mouse mode: This mouse mode sets the client cursor in the middle of the client system and will send the deviation to the host. This mouse mode is specific for SUSE Linux installation.

NOTEClient cursor will be hidden always. If you want to enable, use Alt + C to access the menu.

Options

Block Privilege Request To enable or disable the access privilege of the user.

Keyboard/ Mouse Encryption

This option allows you to encrypt keyboard inputs and mouse movements sent between the connections

Keyboard Keyboard Layout

List of Host Physical Keyboard languages supported in H5Viewer.1. English US2. German3. Japanese

Video Record

Record Video This option is to start recording the screen.StopRecording This option is used to stop the recording.

Record Settings This option is used to set Video Recording Duration.

Page 57: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

49

Chapter 5. BMC Configuration SettingsAuriga User Manual

Send Keys

Hold Down

Right <Ctrl>This menu item can be used to act as the right-side <CTRL> key during Console Redirection.

Right <Alt>This menu item can be used to act as the right-side <ALT> key during Console Redirection.

Right <Window>This menu item can be used to act as the right-side <WIN> key during Console Redirection.

Left <Ctrl>This menu item can be used to act as the left-side <CTRL> key during Console Redirection.

Left <Alt>This menu item can be used to act as the left- side <ALT> key during Console Redirection.

Left <Window>

This menu item can be used to act as the left- side <WIN> key during Console Redirection. You can also decide how the key should be pressed: Hold Down or Press and Release.

Press andRelease

<Ctrl> + <Alt> + <Del>

This menu item can be used to act as if you depressed the <CTRL>, <ALT> and <DEL> keys down simultaneously on the server that you are redirecting.

Left <Windows>

This menu item can be used to act as the left- side <WIN> key during Console Redirection. You can also decide how they key should be pressed: Hold Down or Press and Release.

Right <Windows>This menu item can be used to act as the right-side <WIN> key during Console Redirection.

<Context Menu>This menu item can be used to act as the context menu key, during Console Redirection.

<Print Screen>This menu item can be used to act as the print screen key, during Console Redirection.

Hot Keys Add Hot Keys This menu is used to enable macros. Click Add to macros.

Power

Power Reset To reboot the system without powering off (warm boot).Immediate Shutdown Power Off the server immediately.Orderly Shutdown Soft power off.Power On To power on the server.Power Cycle To first power off, and then reboot the system (cold boot).

Active Users Read only. Displays active user and their system IP address.Help Read only. Displays information about H5viewer.

Page 58: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

50

Chapter 5. BMC Configuration SettingsAuriga User Manual

5�2�9 Power ControlThe Power Control page allows you to view and control the power of your server. To open Power Control, click Power Control from the menu bar.

The various options of Power Control are given below.

Power Off: To immediately power off the server.

Power On: To power on the server.

Power Cycle: This option will first power off, and then reboot the system (cold boot).

Hard Reset: This option will reboot the system without powering off (warm boot).

ACPI Shutdown: This option to initiate operating system shutdown prior to the shutdown.

Perform Action: Click this option to perform the selected operation.

Page 59: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

51

Chapter 5. BMC Configuration SettingsAuriga User Manual

5�2�10 MaintenanceThis Maintenance page displays the configuration settings for Backup Configuration, Firmware Image Location, Firmware Information, Firmware Update, Preserve Configuration, Restore Configuration, and Restore Factory Defaults.

Page 60: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

52

Chapter 5. BMC Configuration SettingsAuriga User Manual

Maintenance Description

Backup Configuration

1. Click Check All to backup the selected configuration items. The Backup Configuration page will appear Click Download Config to save the backup file to the client system.

2. Click OK to perform the backup action. The Backup file will be saved in the client system.

3. Click Cancel to cancel the backup process.Firmware ImageLocation

1. Click the configuration items on the list.2. Click Save to save any changes made.

Firmware Information Read only.

BMC Recovery

1. Choose Enable/Disable to start auto-recovery immediately at next reboot.

2. Enter the number of retries to reset the BMC and this count ranges from 1 to 5.

3. Enter the number of retries to recover firmware image during the recovery process and This count ranges from 1 to 5.

4. Address of the server where the firmware image is stored. • IP Address made of 4 numbers separated by dots as in xxx.xxx.xxx.

xxx. • Each number ranges from 0 to 255.• First number must not be 0.

5. Enter the Image Name to edit the default recovery image name is mentioned as rom.ima.• Image name should contain only 10 characters.

Firmware Update

This wizard takes you through the process of firmware upgradation. A reset of the box will automatically follow if the upgrade is completed or cancelled. An option to Preserve All Configuration is available. Enable it, if you wish to preserver configured settings through the upgrade.

Click Start Firmware Update to start the firmware update process.

Preserve Configuration

This page allows the user to configure the preserve configuration items, which will be used by the Restore factory defaults to preserve the existing configuration without overwriting with defaults/Firmware Upgrade configuration.

Click Save to save any changes made.Restore Configuration

1. Click Upload to restore the backup files.2. Click OK to upload the new configuration file and restore.

Restore Factory Defaults

1. Click the configuration items on the list to preserve the settings during restore factory default configuration.2. Click Restore Factory Defaults to restore the factory defaults of the device firmware.

System Administrator Modified administrator account information

Page 61: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

53

Chapter 5. BMC Configuration SettingsAuriga User Manual

5�2�11 Sign outTo log out of the BMC:

Method 1: Click Sign out from the menu bar. The Logout dialog box will pop out.

Method 2: Click the root quick button on the top right corner of the screen.

OK Cancel

Page 62: Auriga - AIC · AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind

Chapter 6� Technical Support

Taiwain, Global HeadquartersAddress: No� 152, Section 4, Linghang N� Rd, Dayuan District, Taoyuan City 337, TaiwanTel: +886-3-433-9188Fax: +886-3-287-1818Sales Email: sales@aicipc�com�twSupport Email: support@aicipc�com

Shanghai, ChinaAddress: Room 1009, No� 777, Zhaojia Bang Rd, Shanghai 200032,Shanghai, ChinaTel: +86-21-54961421Fax +86-21-54961422 #608Sales Email: csales@aicipc�com�twSupport Email: support@aicipc�com

Moscow, RussiaAddress: Khoroshevskoye Shosse, 32A, Office 403 (2nd Entrance, 4th Floor), Moscow 123007, RussiaTel: +7-4997019998Sales Email: support-ru@aicipc�com�twSupport Email: support-ru@aicipc�com�tw

North California, United StatesAddress: 48531 Warm SpringsBoulvard Suite 404 Fremont, CA 94539, United StatesTel: +1-510-573-6730Fax: +1-510-573-6729Sales Email: sales@aicipc�comSupport Email: support@aicipc�com

South California, United StatesAddress: 21808 Garcia LaneCity of Industry, CA 91789, United StatesToll free: +7-4997019998Tel: +1-909-895-8989Fax: +1-909-895-8989#157Sales Email: sales@aicipc�comSupport Email: support@aicipc�com

New Jersey, United StatesAddress: 11 Melanie Lane Unit #20 & 21 East Hanover, NJ 07936, United StatesTel: +1-973-884-8886Fax: +1-973-884-4794Sales Email: sales@aicipc�comSupport Email: support@aicipc�com

Houten, The NetherlandsAddress: Peppelkade 58, 3992AK, Houten, The NetherlandsTel: +31-30-6386789Fax: +31-30-6360638Sales Email: sales@aicipc�nlSupport Email: support@aicipc�com