Aurora Vision Solution Overview June 2012

Embed Size (px)

Citation preview

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    1/30

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    2/30

    1 Confidential

    Relevance of PV Monitoring Performance Ratio

    California Energy Commission: 67% PR

    Frauenhofer: 73% PR

    PVWATTS: 77%

    PPA Press Release: 85% PR

    Difference of ~$2M per MW over life of system

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    3/30

    2 Confidential

    Lost Energy Detection - Case Study

    Commercial rooftop

    system

    4 years operationwith Inverter-levelonly

    Converted to string-monitoring

    Before

    After

    67%

    PR

    82%

    PR

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    4/30

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    5/30

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    6/30

    5 Confidential

    Aurora Vision Unified Solution

    Unified Plant

    Management

    Power-One

    Sales andSupport

    Expertise and

    Design Support

    Power-One

    World Class

    Manufacturing

    Aurora Vision

    Hardware

    Aurora Vision

    Software

    Silicon Valley

    Technical

    Center ofExcellence

    Fat Spaniel Software

    Features

    MYPVDATA SoftwareFeatures

    SolarMagic Hardware

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    7/30

    6 Confidential

    Breadth and Width of Aurora Vision Solution

    Residential. Commercial Utility

    Unified Monitoring Architecture

    Design Support

    Data Loggers

    Communication HW

    Data Hosting & API

    Software as a Service

    Revenue-Grade Metering

    Weather Stations

    Smart Combiners

    Agency Reporting

    3rdParty HW Support

    On-Site Commissioning

    Support

    Bankability

    C

    o

    m

    p

    l

    e

    t

    e

    S

    o

    l

    u

    ti

    o

    n

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    8/30

    7 Confidential

    Residential Monitoring Solutions

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    9/30

    8 Confidential

    Local Monitoring

    Lowest cost monitoring -

    ~$100 Connects to homeowners

    laptop or desktop via adapter

    Free Aurora Communicator

    software Rich data set

    Voltage/current for each MPPT block

    Lifetime, Today, Last 7 days, Last Month,Last 30 Days, Last 365 Days

    Grid voltage, current, frequency, & powertransferred to the grid

    Serial Number/Code, production week, Firmwarerevision code

    Order as PVI-USB-RS485-232

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    10/30

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    11/30

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    12/30

    11 Confidential

    Easy InstallationStep 1: Wire RS485 to inverter

    Step 2: Connect to internet Step 3: Plug into AC outlet

    Internet

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    13/30

    12 Confidential

    Easy Provisioning

    One time only: Call Power-One Tech Support (877-261-1374) and establish an Aurora Vision Login

    For each install

    1. Create the site

    2. Associate data logger serial number to that site

    3. Share the plant and provide the URL to the homeowner

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    14/30

    13 Confidential

    Remote Residential Monitoring Overview

    Order as VSN-MGR-RES-P1-US

    ~$600 solution Data logger provides 30-days buffering

    Includes hardware, license for inverter(s), datahosting/software for 10 years

    Installer gets O&M view Tracking of fleet and equipment performance

    Proactive customer support

    Homeowner gets pretty public view

    *No need for modbus adapter

    *Applications requiring support for non-Power-One inverters need to use different part number

    *Applications requiring revenue-grade meter or weather stations need to use commercial kits

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    15/30

    14 Confidential

    Public Display View

    Can be viewed from justabout any internetbrowser anywhere!

    Customizedgraphics/logos across top

    Auto scrolling option

    Can be embedded asiframe

    Post to your Facebook!!

    Company logo here!

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    16/30

    15 Confidential

    Commercial and Utility Monitoring Solutions

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    17/30

    16 Confidential

    Aurora Vision Commercial Use Solution

    Monitoring ofAurora Inverters

    Aurora Smart Combiner

    for string-level

    monitoring of 8, 12, 16,

    20 strings

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    18/30

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    19/30

    18 Confidential

    Total system watts 250,000

    Watts per string 3,640

    Annual kWh/W 1.4Annual kWh/string 350000$$/kWh 0.25$

    Annual value 87,500$Increased production 5%

    Increased annual production value 4,375$

    Number of strings in system 69Cost of string-level monitoring hardware 7,935$

    Cost of standard combiners 3,450$Incremental cost for string-level monitoring 4,485$Annualized cost of string-level monitoring hardware 224$

    Annual monitoring fee 368$

    Total annual cost of string-level monitoring 592$

    Fill in the yellow highlighted cells with your system's information

    Cost-Benefit Analysis 250KW Plant Example

    Typically only 1% more energy harvest needed to pay forstring-monitoring

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    20/30

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    21/30

    20 Confidential

    Aurora Enviornmental Key Features

    Easy installation

    Six sensor

    Horizontal Irradiance

    Plane-of-Array Irradiance

    Panel temperature

    Ambient temperature

    Wind speed

    Wind direction

    SunSpec Compliant

    Flexibile placement withModbus/RS485

    Order as VSN-ENVIRO-CMML

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    22/30

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    23/30

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    24/30

    23 Confidential

    Portfolio Page

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    25/30

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    26/30

    25 Confidential

    Plant Symmetry Analysis

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    27/30

    26 Confidential

    Plant Symmetry Analysis

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    28/30

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    29/30

  • 8/10/2019 Aurora Vision Solution Overview June 2012

    30/30