http://www.worstpolluted.org/全世界 70%鉛產能用於生產鉛酸電池70% of W/W lead output was used to produce lead acid battery.

+Environment Concern of Battery

To extend lead acid battery life equals to environment protection.

+Activated Equipment

Output Current: 10A(Max) Output Current: 5A(Max)

+Failed batteries will be written off

These batteries were stored more than 3~6 months.

+Activated Process

Test the voltage, resistance and CCA. Record. Connect to equipment Set up activated time Remove equipment to test after 1 hour. Data analysis: Pass, failed or re-activate

again.

+Under Activated

+Activated Result

No.

Battery Type Initial ActivatedRemarkCap(Ah

) DIN(A) V R DIN V R DIN

NEW 110 52012.6

7 2.95 586 N.A Inventory

NEW 69 36012.5

1 3.78 459 N.A Inventory

1 69 36011.6

1 NA 9 10.9 NA 60Plate broken? TBD

2 110 52011.6

221.3

6 8112.9

7 3.33 519Pass

3 92 52012.4

5 3.62 47912.7

3 3.1 560Pass

4 72 38012.7

8 4.22 40912.9

3 4.03 429Pass

5 110 52012.4

9 3.45 50312.7

9 2.92 592Pass

6 110 52010.5

5 84.2 2010.9

949.7

8 34Plate broken? TBD

7 110 52012.5

8 4.77 36312.8

2 4.48 387Need to active again.

Date: 4/6/2016

+Capacity vs. discharge cycle

+Conclusion

7pcs were activated. 2pcs were determined plate broken, could not be repaired.

There are 4pcs had been activated return as standard or better than new battery. Activated rate 80%.

No. 7 can do one more repair process to reduce resistance and increase CCA to achieve 100% activated rate.

+