Upload
edward-chen
View
51
Download
0
Embed Size (px)
Citation preview
+
Auto BatteryEdward ChenFirst Battery [email protected]+886933719664
+污染物威脅排名
http://www.worstpolluted.org/全世界 70%鉛產能用於生產鉛酸電池70% of W/W lead output was used to produce lead acid battery.
+Activated Process
Test the voltage, resistance and CCA. Record. Connect to equipment Set up activated time Remove equipment to test after 1 hour. Data analysis: Pass, failed or re-activate
again.
+Activated Result
No.
Battery Type Initial ActivatedRemarkCap(Ah
) DIN(A) V R DIN V R DIN
NEW 110 52012.6
7 2.95 586 N.A Inventory
NEW 69 36012.5
1 3.78 459 N.A Inventory
1 69 36011.6
1 NA 9 10.9 NA 60Plate broken? TBD
2 110 52011.6
221.3
6 8112.9
7 3.33 519Pass
3 92 52012.4
5 3.62 47912.7
3 3.1 560Pass
4 72 38012.7
8 4.22 40912.9
3 4.03 429Pass
5 110 52012.4
9 3.45 50312.7
9 2.92 592Pass
6 110 52010.5
5 84.2 2010.9
949.7
8 34Plate broken? TBD
7 110 52012.5
8 4.77 36312.8
2 4.48 387Need to active again.
Date: 4/6/2016
+Conclusion
7pcs were activated. 2pcs were determined plate broken, could not be repaired.
There are 4pcs had been activated return as standard or better than new battery. Activated rate 80%.
No. 7 can do one more repair process to reduce resistance and increase CCA to achieve 100% activated rate.