14
Automated Validation Automated Validation Tester II Tester II Decker Technology, Inc Decker Technology, Inc

Automated Validation Tester II Decker Technology, Inc

Embed Size (px)

Citation preview

Page 1: Automated Validation Tester II Decker Technology, Inc

Automated Validation Automated Validation Tester IITester II

Decker Technology, IncDecker Technology, Inc

Page 2: Automated Validation Tester II Decker Technology, Inc

AVT-IIAVT-II

Page 3: Automated Validation Tester II Decker Technology, Inc

IntroductionIntroduction

The AVT-II is an automated validation The AVT-II is an automated validation tester for any type gaslift valve.tester for any type gaslift valve.

A computer directs the AVT-II to test A computer directs the AVT-II to test opening and closing pressure, opening and closing pressure, effective stem travel, loadrate, port effective stem travel, loadrate, port leak rate, and R ratio.leak rate, and R ratio.

A Pass/Fail indicator shows the status A Pass/Fail indicator shows the status of all tests. of all tests.

Page 4: Automated Validation Tester II Decker Technology, Inc

AVT-II CapabilitiesAVT-II Capabilities

Test any valve at pressures to 3000 psigTest any valve at pressures to 3000 psig Save, print, or post test results to networkSave, print, or post test results to network Can test 3 valves simultaneouslyCan test 3 valves simultaneously Uses very little nitrogenUses very little nitrogen Select any convenient units of measureSelect any convenient units of measure Requires very little trainingRequires very little training Much more accurate and consistent than Much more accurate and consistent than

manual testingmanual testing

Page 5: Automated Validation Tester II Decker Technology, Inc

AVT-II Software FeaturesAVT-II Software Features

Perpetual software license with purchasePerpetual software license with purchase Stations can be run individually or simultaneouslyStations can be run individually or simultaneously Once valve is loaded, performs a complete set of Once valve is loaded, performs a complete set of

tests in less than 20 seconds.tests in less than 20 seconds. Calibration routine for each test stationCalibration routine for each test station Stores data from each test in spreadsheet formatStores data from each test in spreadsheet format Test screen shows real time pressure trace of Test screen shows real time pressure trace of

each station as test is conductedeach station as test is conducted User inputs Pass/Fail criteriaUser inputs Pass/Fail criteria

Page 6: Automated Validation Tester II Decker Technology, Inc

AVT-II Main ScreenAVT-II Main Screen

Page 7: Automated Validation Tester II Decker Technology, Inc

AVT-II Hardware FeaturesAVT-II Hardware Features

Components are highest quality…Components are highest quality…– Sensotec transducers +/-.1% accuracySensotec transducers +/-.1% accuracy– High reliability solenoidsHigh reliability solenoids– Data Acquisition system by National Data Acquisition system by National

InstrumentsInstruments– All stainless steel fittings and manifoldAll stainless steel fittings and manifold– Rated to 3000 psig working pressureRated to 3000 psig working pressure

Page 8: Automated Validation Tester II Decker Technology, Inc

AVT-II Hardware FeaturesAVT-II Hardware Features

Small desktop footprint (15x18 inches)Small desktop footprint (15x18 inches) Changing valves is quick and easy. Changing valves is quick and easy.

About 2 minutes.About 2 minutes. Run over 3000 tests on a single bottle Run over 3000 tests on a single bottle

of nitrogen (New nitrogen bottle at 2500 of nitrogen (New nitrogen bottle at 2500 psig and valve set at Pvct = 1275 psig)psig and valve set at Pvct = 1275 psig)

Change valves in one station while Change valves in one station while other stations continue to test.other stations continue to test.

Page 9: Automated Validation Tester II Decker Technology, Inc

Business JustificationBusiness Justification

Use the AVT-II to qualify valves during Use the AVT-II to qualify valves during setup in the gaslift workshopsetup in the gaslift workshop

Use the AVT-II to test valves returned Use the AVT-II to test valves returned from the field. Build a data base of from the field. Build a data base of valve use.valve use.

Testing is consistent and more accurate Testing is consistent and more accurate than analog gaugesthan analog gauges

Safe and easy to use. Does not require Safe and easy to use. Does not require an experienced gaslift shop technicianan experienced gaslift shop technician

Page 10: Automated Validation Tester II Decker Technology, Inc

Business JustificationBusiness Justification

Print a certificate showing…Print a certificate showing…– Ptro, Pvct, R ratio, Port leak rate, Stem Ptro, Pvct, R ratio, Port leak rate, Stem

travel, and loadratetravel, and loadrate– Date of test, Valve type, and serial numberDate of test, Valve type, and serial number

ReliableReliable Field ProvenField Proven Much more thorough testing of valve Much more thorough testing of valve

than current gaslift shop practicesthan current gaslift shop practices

Page 11: Automated Validation Tester II Decker Technology, Inc

Business JustificationBusiness Justification

Reduce the number of wireline re-entries Reduce the number of wireline re-entries due to failed or under performing valves due to failed or under performing valves (field proven in Oman!)(field proven in Oman!)

Maintain a database of the number of times Maintain a database of the number of times a valve has been re-useda valve has been re-used

Added assurance that the valves sent to the Added assurance that the valves sent to the field will perform as engineer anticipates.field will perform as engineer anticipates.

Better gaslift performance and less wireline Better gaslift performance and less wireline work.work.

Page 12: Automated Validation Tester II Decker Technology, Inc

AVT-II WarrantyAVT-II Warranty

Parts warranted for 1 year from date of Parts warranted for 1 year from date of implementing.implementing.– Labor free of charge if repair requiredLabor free of charge if repair required– Travel expenses at costTravel expenses at cost– Software maintenance free for first yearSoftware maintenance free for first year

Software upgrade to new operating Software upgrade to new operating system available at cost.system available at cost.

Telephone support available free for Telephone support available free for first year of service.first year of service.

Page 13: Automated Validation Tester II Decker Technology, Inc

AVT-II AvailabilityAVT-II Availability

1, 2, or 3 station AVT-II available 15 1, 2, or 3 station AVT-II available 15 weeks from receipt of orderweeks from receipt of order

Spare parts kit availableSpare parts kit available User manual includedUser manual included

Page 14: Automated Validation Tester II Decker Technology, Inc

Contact InformationContact Information

Decker Technology, IncDecker Technology, Inc– 2238 McCurdy Road2238 McCurdy Road– Stone Mountain, GA 30087Stone Mountain, GA 30087

Telephone - 770-496-9680Telephone - 770-496-9680 Fax - 770-496-9681Fax - 770-496-9681 Email - [email protected] - [email protected]