VER.18.1GENERAL CATALOG
Awex brand has been existing in the emergency lighting sector since 2002, invariably fulfilling its clearly defined mission: top-quality state-of-the-art products and customer satisfaction. We offer the full range of emergency lighting devices in compliance with all the European standards. Within 15 years of our market presence, we gained the leading position in the industry thanks to the involvement of knowledge, means, cooperation with best specialists, including research facilities, and investments in innovative projects. Awex means the latest technologies, experienced team of designers and engineers, top quality, reliable equipment, diversity of offer, unique design, unlimited productivity and unblemished reputation supported by references. The biggest award is satisfied and trusted customers. We also enjoy the recognition of independent experts. We were awarded the title of the “Export Leader 2006” for our business volume, and the Puls Biznesu awarded us twice with the “Business Gazelles” prize as one of the most dynamically developing companies in Poland.
PROFESSIONAL PERSONNEL
We employ the best specialists in many different fields for whom we ensure constant improvement in qualifications by specialist trainings. The company’s design department provides flexible design of individual orders and the team of highly qualified engineers ensures continuous technological progress of offered equipment. The use of modern information flow methods within the company ensures that the offer and functionality of products is updated on an ongoing basis. The effcient project management allows building permanent and trust-based relationships with customers.
INVESTMENTS
We use the latest world technologies to guarantee quality, precise workmanship, optimised technological process, and work ergonomics. We invest time and means so that every stage of manufacturing our products contributes to meeting any expectations of our customers.
TESTS
The research and development works ensure that our offer is constantly updated according to development trends in the industry, and thus we can supply the most modern, multifunctional and technologically advanced products.
WE TAKE CARE OF THE ENVIRONMENT
We offer the environment-friendly products and the manufacturing process meets strict EU standards.
QUALITY WARRANTY
Due to the purpose of the company’s mission realization, we have initiated the Quality Control System according to the EN ISO 9001:2008, and the received TÜV NORD certificate guarantees the highest projects quality as well as the production, assemble and service of the emergency lighting devices. In 2016 the company Awex received, for the new products in scope of the fittings and systems of the emergency lighting, a prestige and recognized all over the world the BSI certificate. The certificate’s receipt is related to a long procedure and very restricted tests which we had to do. It proves the highest technical quality of the offered products.
TABLE OF CONTENTS
EMERGENCY ESCAPE LIGHTING 5
EXIT S
ARROW N 12ARROW P 14LOVATO II 16LOVATO P 18AXN 20AXP EYE LED round 24EYE LED square 26
SPY II 30HELIOS LED 32HELIOS
TIGER 37TIGER LED
OUTDOOR LED 40SK-8 42INFINITY II EDGE R 46
JOBLED
EMERGENCY EXIT SIGNS 51
52ARROW P 54EXIT S EXIT M 58EXIT L 60INFINITY II AW 62INFINITY II AC & INFINITY II AL INFINITY II B SK-8 68TWINS 70PLEXI LED 72ESCAPE LED 74HELIOS & HELIOS LED 76HELIOS DS & HELIOS DS LED 78TIGER & TIGER LED 80TIGER DS & TIGER DS LED 82SCREEN 84
EXIT M 8EXIT L 10
6
MICRO SPOT 28
34
22
44
EDGE S 48
ARROW N
56
6466
SCREEN DS 86
QUADRO 88
EMERGENCY CONVERSION KITS
100101
UNILED BM 102UNILED UM 104EML 106
SYSTEMS 109
RUBIC MINI UNA 110RUBIC UNA 111
CENTRAL BATTERY SYSTEM FZLV 118
CENTRAL BATTERY SYSTEM LPS 122CENTRAL BATTERY SYSTEM CBS 124THE SMART VISIO PLATFORM
ADDITIONAL COMPONENTS
FOR LOW TEMPERATURE
130
BATTERIESACCESSORIES 132PICTOGRAMS
INFORMATION FOR READERS
PHOTOMETRY 138
SPECIAL APPLICATION 91
92ESCAPELITE 94ESCAPELITE LFLAGLIGHT 96WALL LINE 97
IKLED
95
LUMINAIRES
99
NEXT & NEXT AUTOTESTUNILED GU10
RUBIC UNA WIRELESS 112DYNAMIC ESCAPE SYSTEM DES 114FIRE ALARM SYSTEM FAS 116
CENTRAL BATTERY SYSTEM SPS 120
126
129
HTR 25 - HEATER WITH THERMOSTAT
131
134
137
USED SYMBOLS 164
38
36
emergency escape lighting
TIGER JOB LED OUTDOOR LED SK-8 INFINITY II
EYE LED round EYE LED square SPY II HELIOS LED
TIGER LEDHELIOS
EXIT S
ARROW N 12ARROW P 14LOVATO II 16LOVATO P 18AXN 20AXP EYE LED round 24EYE LED square 26
SPY II 30HELIOS LED 32HELIOS
TIGER 37TIGER LED
JOBLED
EXIT M 8EXIT L 10
6
MICRO SPOT 28
34
22
OUTDOOR LED 40SK-8 42INFINITY II EDGE R 46
44
EDGE S 48
EXIT LEXIT S EXIT M ARROW N ARROW P LOVATO II LOVATO P
AXN AXP MICRO SPOT
EDGE SEDGE R
36
38
Emergency escape lighting
6
EXIT S
White, grey or black polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
Optionally recessed** (wall, ceiling)
Optionally pendant*** (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, 3W LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP65
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
t : -25°C ÷ 40°C – together with heater for low temperaturesa
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
III class of insulation of FZLV version
**requires an accessory for recessed mounting, RW option not available
***requires an accessory for pendant mounting
220-240V
AC50-60Hz
24VDC
LED
Ni-Cd
IP65176-275V
LiFePO4
DC
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
MATERIALS:
DIMENSIONS (mm):
RECESSING CUT (mm):
• wall
• ceiling
25
226
12
5
10
5
42
RW – RUBIC UNA Wireless central monitoring
Emergency escape lighting
7
ETS – fitting EXIT S
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring system
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
BL – black color
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
ETSETSR ETSU
1W E 1 3 SE PT X WH GR BL
STANDARD
ETSETSR ETSU
1W C 1 3 SA PT X WH GR BL
2W C 1 3 SA PT X WH GR BL
PREMIUM
ETSETSR ETSU
1W B 1 3 SA AT RU RW WH GR BL
2W B 1 3 SA AT RU RW WH GR BL
3W B 1 3 SA AT RU RW WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
ETSETSR ETSU
1W F CB CBS X WH GR BL
2W F CB CBS X WH GR BL
3W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
ETSETSR ETSU
1W Z CB ADE ADP WH GR BL
2W Z CB ADE ADP WH GR BL
3W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
ETSETSR ETSU
1W FZLV WH GR BL
2W FZLV WH GR BL
3W FZLV WH GR BL
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
ETS ETSR ETSU
BASIC
1W 125 125 135
STANDARD
1W 125 125 135
2W 235 235 270
PREMIUM
1W 130 130 150
2W 265 265 300
3W 360 360 425
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
ETS ETSR ETSU
1W 130 130 150
2W 265 265 300
3W 360 360 425
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
ETS ETSR ETSU
1W 130 130 150
2W 265 265 300
3W 360 360 425
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
ETS ETSR ETSU
1W 130 130 150
2W 265 265 300
3W 360 360 425
RW – RUBIC UNA Wireless central monitoring
LEGEND:
Emergency escape lighting
8
White, grey or black polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
Optionally recessed** (wall, ceiling)
Optionally pendant*** (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, 3W LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP65
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
t : -25°C ÷ 40°C – together with heater for low temperaturesa
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
III class of insulation of FZLV version
**requires an accessory for recessed mounting, RW option not available
***requires an accessory for pendant mounting
RECESSING CUT (mm):
• wall
• ceiling
44
276
14
3
44
DIMENSIONS (mm):
220-240V
AC50-60Hz
24VDC
LED
Ni-Cd
IP65176-275V
LiFePO4
DC
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
EXIT M
MATERIALS:
RW – RUBIC UNA Wireless central monitoring
Emergency escape lighting
9
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
CODE POWER MODULE SYSTEM OPTIONS COLOR POWER OUTPUT [lm]
CODE POWER MODULE SYSTEM OPTIONS COLOR POWER OUTPUT [lm]
CODE POWER SYSTEM COLOR POWER OUTPUT [lm]
LEGEND:
ETE – fitting EXIT M
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring system
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
BL – black color
SELF-CONTAINED CONFIGURATION
BASIC
ETE 1W E 1 3 SE PT X WH GR BL
STANDARD
1W C 1 3 SA PT X WH GR BL
ETE 2W C 1 3 SA PT X WH GR BL
3W C 1 3 SA PT X WH GR BL
PREMIUM
1W B 1 3 SA AT RU RW WH GR BL
ETE 2W B 1 3 SA AT RU RW WH GR BL
3W B 1 3 SA AT RU RW WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
1W F CB CBS X WH GR BL
ETE 2W F CB CBS X WH GR BL
3W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
1W Z CB ADE ADP WH GR BL
ETE 2W Z CB ADE ADP WH GR BL
3W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION
1W FZLV WH GR BL
ETE 2W FZLV WH GR BL
3W FZLV WH GR BL
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
BASIC
1W 130
STANDARD
1W 130
2W 250
3W 320
PREMIUM
1W 135
2W 270
3W 350
OUTPUT IN EMERGENCY MODE
1W 130
2W 270
3W 350
OUTPUT IN EMERGENCY MODE
1W 130
2W 270
3W 350
OUTPUT IN EMERGENCY MODE
1W 130
2W 270
3W 350
RW – RUBIC UNA Wireless central monitoring
Emergency escape lighting
10
White, grey or black polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
Optionally recessed** (wall, ceiling)
Optionally pendant*** (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, 3W, 6W LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP65
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
t : -25°C ÷ 40°C – together with heater for low temperaturesa
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
III class of insulation of FZLV version
**requires an accessory for recessed mounting, RW option not available
***requires an accessory for pendant mounting
RECESSING CUT (mm):
• wall
• ceiling
220-240V
AC50-60Hz
24VDC
LED
Ni-Cd
IP65176-275V
LiFePO4
DC
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
EXIT L
MATERIALS:
RW – RUBIC UNA Wireless central monitoring
DIMENSIONS (mm):
52
332
17
8
52
Emergency escape lighting
11
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
CODE POWER MODULE SYSTEM OPTIONS COLOR POWER OUTPUT [lm]
CODE POWER MODULE SYSTEM OPTIONS COLOR POWER OUTPUT [lm]
CODE POWER SYSTEM COLOR POWER OUTPUT [lm]
LEGEND:
ETL – fitting EXIT L
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring system
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
BL – black color
RW – RUBIC UNA Wireless central monitoring
SELF-CONTAINED CONFIGURATION
BASIC
ETL 1W E 1 3 SE PT X WH GR BL
STANDARD
1W C 1 3 SA PT X WH GR BL
ETL 2W C 1 3 SA PT X WH GR BL
3W C 1 3 SA PT X WH GR BL
PREMIUM
ETL
1W B 1 3 SA AT RU RW WH GR BL
2W B 1 3 SA AT RU RW WH GR BL
3W B 1 3 SA AT RU RW WH GR BL
6W B 1 3 SE AT RU RW WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
ETL
1W F CB CBS X WH GR BL
2W F CB CBS X WH GR BL
3W F CB CBS X WH GR BL
6W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
ETL
1W Z CB ADE ADP WH GR BL
2W Z CB ADE ADP WH GR BL
3W Z CB ADE ADP WH GR BL
6W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION
1W FZLV WH GR BL
ETL 2W FZLV WH GR BL
3W FZLV WH GR BL
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
BASIC
1W 125
STANDARD
1W 125
2W 255
3W 380
PREMIUM
1W 140
2W 280
3W 425
6W 850
OUTPUT IN EMERGENCY MODE
1W 140
2W 280
3W 425
6W 850
OUTPUT IN EMERGENCY MODE
1W 140
2W 280
3W 425
6W 850
OUTPUT IN EMERGENCY MODE
1W 140
2W 280
3W 425
Emergency escape lighting
12
MATERIALS:
White, grey or black polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
3x1W power LED
S – without optics
O – open area
C – escape route
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO4 6,4V batteries
INSULATION CLASS:
II or III
IP RATING:
IP40
AMBIENT TEMPERATURE:
ta: 0°C - +40°C
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
43
299
76
220-240V
AC50-60Hz
24VDC
LED
Ni-Cd
176-275VDC
DIMENSIONS (mm):
LiFePO4
KM 61835 BS-EN
IP40
Current list of products with Kitemark and ENEC is available at www.awex.eu
ARROW N
Emergency escape lighting
13
LEGEND:
ARNS – fixture ARROW N without optics
ARNO – fixture ARROW N with optics for open area
ARNC – fixture ARROW N with optics for escape route
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring system
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
BL – black color
SELF-CONTAINED CONFIGURATION
BASIC
ARNS 1W E 1 3 SE PT X WH GR BL
STANDARD
ARNS1W C 1 3 SA PT X WH GR BL
2W C 1 3 SA PT X WH GR BL
ARNO ARNC 3x1W C 1 3 SA PT X WH GR BL
PREMIUM
ARNS1W B 1 3 SA AT RU WH GR BL
2W B 1 3 SA AT RU WH GR BL
ARNO ARNC 3x1W B 1 3 SA AT RU WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
ARNS1W F CB CBS X WH GR BL
2W F CB CBS X WH GR BL
ARNO ARNC 3x1W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
ARNS1W Z CB ADE ADP WH GR BL
2W Z CB ADE ADP WH GR BL
ARNO ARNC 3x1W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
ARNS1W FZLV WH GR BL
2W FZLV WH GR BL
ARNO ARNC 3x1W FZLV WH GR BL
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
ARNS ARNO ARNC
BASIC
1W 110 X X
STANDARD
1W 110 X X
2W 200 X X
3x1W X 250 250
PREMIUM
1W 120 X X
2W 220 X X
3x1W X 270 270
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
ARNS ARNO ARNC
1W 120 X X
2W 220 X X
3x1W X 270 270
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
ARNS ARNO ARNC
1W 120 X X
2W 220 X X
3x1W X 270 270
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
ARNS ARNO ARNC
1W 120 X X
2W 220 X X
3x1W X 270
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
CODE POWER MODULE SYSTEM OPTIONS COLOR
CODE POWER MODULE SYSTEM OPTIONS COLOR
270
Emergency escape lighting
14
ARROW P
MATERIALS:
White, grey or black polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
3x1W power LED
S – without optics
O – open area
C – escape route
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO4 6,4V batteries
INSULATION CLASS:
II or III
IP RATING:
IP40
AMBIENT TEMPERATURE:
ta: 0°C - +40°C
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
62328
76
220-240V
AC50-60Hz
24VDC
LED
Ni-Cd
176-275VDC
LiFePO4
IP40
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
DIMENSIONS (mm):
300 x 45
RECESSING CUT (mm):
• ceiling
Emergency escape lighting
15
270
LEGEND:
ARPS – fixture ARROW P without optics
ARPO – fixture ARROW P with optics for open area
ARPC – fixture ARROW P with optics for escape route
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring system
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
BL – black color
SELF-CONTAINED CONFIGURATION
BASIC
ARPS 1W E 1 3 SE PT X WH GR BL
STANDARD
ARPS1W C 1 3 SA PT X WH GR BL
2W C 1 3 SA PT X WH GR BL
ARPO ARPC 3x1W C 1 3 SA PT X WH GR BL
PREMIUM
ARPS1W B 1 3 SA AT RU WH GR BL
2W B 1 3 SA AT RU WH GR BL
ARPO ARPC 3x1W B 1 3 SA AT RU WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
ARPS1W F CB CBS X WH GR BL
2W F CB CBS X WH GR BL
ARPO ARPC 3x1W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
ARPS1W Z CB ADE ADP WH GR BL
2W Z CB ADE ADP WH GR BL
ARPO ARPC 3x1W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
ARPS1W FZLV WH GR BL
2W FZLV WH GR BL
ARPO ARPC 3x1W FZLV WH GR BL
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
ARPS ARPO ARPC
BASIC
1W 110 X X
STANDARD
1W 110 X X
2W 200 X X
3x1W X 250 250
PREMIUM
1W 120 X X
2W 220 X X
3x1W X 270 270
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
ARPS ARPO ARPC
1W 120 X X
2W 220 X X
3x1W X 270 270
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
ARPS ARPO ARPC
1W 120 X X
2W 220 X X
3x1W X 270 270
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
ARPS ARPO ARPC
1W 120 X X
2W 220 X X
3x1W X 270
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
CODE POWER MODULE SYSTEM OPTIONS COLOR
CODE POWER MODULE SYSTEM OPTIONS COLOR
270
Emergency escape lighting
16
MATERIALS:
White, grey or black polycarbonate body
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, 3W power LED
Optics
C - corridor
R - escape route
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP41
AMBIENT TEMPERATURE:
t : 0°C - +40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
13
2
132
13
2
132 74
DIMENSIONS (mm):
LOVATO II
O - open area
U - universal
A - asymmetric
RW – RUBIC UNA Wireless central monitoring
KM 61835 BS-EN
220-240VAC
50-60HzIP41
24VDC
LED176-275V
DC
Ni-Cd LiFePO4
54
Emergency escape lighting
17
Output in emergency mode of LB2 is the same like LV2.
LEGEND:
LV2R – fixture Lovato II with optics for escape route
LV2U – fixture Lovato II with universal optics
LV2O – fixture Lovato II with optics for open area
LV2C – fixture Lovato II with optics for corridor
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24 VDC
CB – central battery version
CBS – central battery for circuit monitoring
ADP – central battery with ADP address module – SMART technology
ADE – central battery with ADE address module
WH – white color
GR – grey color
BL – black color
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
LV2R LV2U LV2O LV2C LV2A LB2R LB2U LB2O LB2C LB2A
1W E 1 3 SE PT X WH GR BL
STANDARD
LV2R LV2U LV2O LV2C LV2A LB2R LB2U LB2O LB2C LB2A
1W C 1 3 SA PT X WH GR BL
2W C 1 3 SA PT X WH GR BL
3W C 1 3 SA PT X WH GR BL
PREMIUM
LV2R LV2U LV2O LV2C LV2A LB2R LB2U LB2O LB2C LB2A
1W B 1 3 SA AT RU RW WH GR BL
2W B 1 3 SA AT RU RW WH GR BL
3W B 1 3 SA AT RU RW WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
LV2R LV2U LV2O LV2C LV2A LB2R LB2U LB2O LB2C LB2A
1W F CB CBS X WH GR BL
2W F CB CBS X WH GR BL
3W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE:
CODE POWER MODULE SYSTEM OPTIONS COLOR
LV2R LV2U LV2O LV2C LV2A LB2R LB2U LB2O LB2C LB2A
1W Z CB ADE ADP WH GR BL
2W Z CB ADE ADP WH GR BL
3W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION:
CODE POWER SYSTEM COLOR
LV2R LV2U LV2O LV2C LV2A LB2R LB2U LB2O LB2C LB2A
1W FZLV WH GR BL
2W FZLV WH GR BL
3W FZLV WH GR BL
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
LV2R LV2U LV2O LV2C LV2A
BASIC
1W 140 130 130 140 130
STANDARD
1W 140 130 130 140 130
2W 240 240 240 240 250
3W 340 350 350 330 345
PREMIUM
1W 140 140 140 150 140
2W 250 270 270 240 270
3W 370 390 390 360 370
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
LV2R LV2U LV2O LV2C LV2A
1W 140 140 140 150 140
2W 250 270 270 240 270
3W 370 390 390 360 370
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
LV2R LV2U LV2O LV2C LV2A
1W 140 140 140 150 140
2W 250 270 270 240 270
3W 370 390 390 360 370
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
LV2R LV2U LV2O LV2C LV2A
1W 140 140 140 150 140
2W 250 270 270 240 270
3W 370 390 390 360 370
LV2A – fixture Lovato II with asymmetric optics
LB2R – fixture Lovato II with large Box and optics for escape route
LB2U – fixture Lovato II with large Box and universal optics
LB2O – fixture Lovato II with large Box and optics for open area
LB2C – fixture Lovato II with large Box and optics for corridor
LB2A – fixture Lovato II with large Box and asymmetric optics
RW – RUBIC UNA Wireless central monitoring
Emergency escape lighting
18
MATERIALS:
White, grey or black polycarbonate body
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries 4
INSULATION CLASS:
II or III
IP RATING:
IP20
AMBIENT TEMPERATURE:
t : 0°C - +40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
Electronic gear and battery package installed in a separate box
95
95
95
47,7
Ø 83mm
h min. 150 mm
IP20
DIMENSIONS (mm):
RECESSING CUT (mm):• ceiling
220-240VAC
50-60Hz
24VDC
LED176-275V
DC
Ni-Cd LiFePO4
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
403
195 8
32
44
1W, 2W, 3W power LED
Optics
C - corridor
R - escape route
O - open area
U - universal
A - asymmetric
LOVATO P
Emergency escape lighting
19
390
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
LVPR LVPU LVPO LVPC LVPA 1W E 1 3 SE PT X WH GR BL
STANDARD
LVPR LVPU LVPO LVPC LVPA
1W C 1 3 SA PT X WH GR BL
2W C 1 3 SA PT X WH GR BL
3W C 1 3 SA PT X WH GR BL
PREMIUM
LVPR LVPU LVPO LVPC LVPA
1W B 1 3 SA AT RU WH GR BL
2W B 1 3 SA AT RU WH GR BL
3W B 1 3 SA AT RU WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
LVPR LVPU LVPO LVPC LVPA
1W F CB CBS X WH GR BL
2W F CB CBS X WH GR BL
3W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE:
CODE POWER MODULE SYSTEM OPTIONS COLOR
LVPR LVPU LVPO LVPC LVPA
1W Z CB ADE ADP WH GR BL
2W Z CB ADE ADP WH GR BL
3W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION:
CODE POWER SYSTEM COLOR
LVPR LVPU LVPO LVPC LVPA
1W FZLV WH GR BL
2W FZLV WH GR BL
3W FZLV WH GR BL
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
LVPR LVPU LVPO LVPC LVPA
BASIC
1W 140 130 130 140 130
STANDARD
1W 140 130 130 140 130
2W 240 240 240 240 250
3W 340 350 350 330 345
PREMIUM
1W 140 140 140 150 140
2W 250 270 270 240 270
3W 370 390 390 360 370
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
LVPR LVPU LVPO LVPC LVPA
1W 140 140 140 150 140
2W 250 270 270 240 270
3W 370 390 390 360 370
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
LVPR LVPU LVPO LVPC LVPA
1W 140 140 140 150 140
2W 250 270 270 240 270
3W 370 390 390 360 370
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
LVPR LVPU LVPO LVPC LVPA
1W 140 140 140 150 140
2W 250 270 270 240 270
3W 370 390 390 360 370
LEGEND:
LVPR – fixture Lovato P with optics for escape route
LVPU – fixture Lovato P with universal optics
LVPO – fixture Lovato P with optics for open area
LVPC – fixture Lovato P with optics for corridor
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24 VDC
CB – central battery version
CBS – central battery for circuit monitoring
ADP – central battery with ADP address module – SMART technology
ADE – central battery with ADE address module
WH – white color
GR – grey color
BL – black color
LVPA – fixture Lovato P with asymmetric optics
Emergency escape lighting
20
MATERIALS:
White, grey or black polycarbonate body
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, 3W, 6W power LED
Optics
C - corridor
R - escape route
O - open area
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP42 or IP65
AMBIENT TEMPERATURE:
t : 0°C - +40°Ca
t : -25°C ÷ 40°C – together with heater for low temperaturesa
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
III class of insulation of FZLV version
58202
20
2
DIMENSIONS (mm):
220-240VAC
50-60Hz
24VDC
LED176-275V
DCIP65 IP42
Ni-Cd
LiFePO4
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
AXN
U - universal
A - asymmetric
RW – RUBIC UNA Wireless central monitoring
Emergency escape lighting
21
LEGEND:
AXNR – fixture AXN IP65 with optics for escape route
AXNU – fixture AXN IP65 with universal optics
AXNO – fixture AXN IP65 with optics for open area
AXENR – fixture AXN IP42 with optics for escape route
AXENU – fixture AXN IP42 with universal optics
AXENO – fixture AXN IP42 with optics for open area
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
AXNR AXNU AXNO AXNC AXNA
1W E 1 3 SE PT X WH GR BL
STANDARD
AXNR AXNU AXNO AXNC AXNA
1W C 1 3 SA PT X WH GR BL
2W C 1 3 SA PT X WH GR BL
3W C 1 3 SA PT X WH GR BL
PREMIUM
AXNR AXNU AXNO AXNC AXNA
1W B 1 3 SA AT RU RW WH GR BL
2W B 1 3 SA AT RU RW WH GR BL
3W B 1 3 SA AT RU RW WH GR BL
6W* B 1 SA AT RU RW WH GR BL
* power in emergency mode
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
AXNR AXNU AXNO AXNC AXNA
1W F CB CBS X WH GR BL
2W F CB CBS X WH GR BL
3W F CB CBS X WH GR BL
6W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
AXNR AXNU AXNO AXNC AXNA
1W Z CB ADE ADP WH GR BL
2W Z CB ADE ADP WH GR BL
3W Z CB ADE ADP WH GR BL
6W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
AXNR AXNU AXNO AXNC AXNA
1W FZLV WH GR BL
2W FZLV WH GR BL
3W FZLV WH GR BL
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
AXNR AXNU AXNO AXNC AXNA
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
AXNR AXNU AXNO AXNC AXNA
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
AXNR AXNU AXNO AXNC AXNA
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
AXNR AXNU AXNO AXNC AXNA
AXNC – fixture AXN IP65 with optics for corridor
AXNA – fixture AXN IP65 with asymmetric optics optics
AXENC – fixture AXN IP42 with optics for corridor
AXENA – fixture AXN IP42 with asymmetric optics optics
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24 VDC
CB – central battery version
CBS – central battery for circuit monitoring
ADP – central battery with ADP address module – SMART technology
ADE – central battery with ADE address module
RW – RUBIC UNA Wireless central monitoring
BASIC
1W 140 140 135 140 130
STANDARD
1W 140 140 135 140 130
2W 240 250 235 240 240
3W 350 360 325 330 345
PREMIUM
1W 150 150 145 150 140
2W 260 270 250 260 260
3W 370 390 350 360 380
6W 600 620 590 600 580
1W 150 150 145 150 140
2W 260 270 250 260 260
3W 370 390 350 360 380
6W 600 620 590 600 580
1W 150 150 145 150 140
2W 260 270 250 260 260
3W 370 390 350 360 380
6W 600 620 590 600 580
1W 150 150 145 150 140
2W 260 270 250 260 260
3W 370 390 350 360 380
3
Output in emergency mode of AXN IP42 is the same like AXN IP65.Code of IP42 version are indicated in the legend
Emergency escape lighting
22
AXP
MATERIALS:
White, grey or black polycarbonate body
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, 3W, 6W power LED
Optics
C - corridor
R - escape route
O - open area
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP20 or IP65/20
AMBIENT TEMPERATURE:
t : 0°C - +40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
Electronic gear and battery package installed in a separate box
Current list of products with Kitemark and ENEC is available at www.awex.eu
220-240VAC
50-60HzIP20
24VDC
IP65/20LED
37100
10
0
DIMENSIONS (mm):
Ø 83mmRECESSING CUT (mm):
h min. 150 mm
• ceiling
LiFePO4
KM 61835 BS-EN
176-275VDC
Ni-Cd
403
195 8
32
44
U - universal
A - asymmetric
Emergency escape lighting
23
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
AXPR AXPU AXPO AXPC AXPA
STANDARD
AXPR AXPU AXPO AXPC AXPA
1W C 1 3 SA PT X WH GR BL
2W C 1 3 SA PT X WH GR BL
3W C 1 3 SA PT X WH GR BL
PREMIUM
AXPR AXPU AXPO AXPC AXPA
1W B 1 3 SA AT RU WH GR BL
2W B 1 3 SA AT RU WH GR BL
3W B 1 3 SA AT RU WH GR BL
6W* B 1 SA AT RU WH GR BL
* power in emergency mode
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
AXPR AXPU AXPO AXPC AXPA
1W F CB CBS X WH GR BL
2W F CB CBS X WH GR BL
3W F CB CBS X WH GR BL
6W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
AXPR AXPU AXPO AXPC AXPA
1W Z CB ADE ADP WH GR BL
2W Z CB ADE ADP WH GR BL
3W Z CB ADE ADP WH GR BL
6W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
AXPR AXPU AXPO AXPC AXPA
1W FZLV WH GR BL
2W FZLV WH GR BL
3W FZLV WH GR BL
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
AXPR AXPU AXPO AXPC AXPA
BASIC
1W E 1 3 SE PT X WH GR BL 1W 140 140 135 145 130
STANDARD
1W 140 140 135 145 130
2W 240 250 240 240 240
3W 340 360 345 340 345
PREMIUM
1W 150 150 145 160 140
2W 260 270 260 260 260
3W 370 390 375 370 380
6W 600 620 615 600 580
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
AXPR AXPU AXPO AXPC AXPA
1W 150 150 145 160 140
2W 260 270 260 260 260
3W 370 390 375 370 380
6W 600 620 615 600 580
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
AXPR AXPU AXPO AXPC AXPA
1W 150 150 145 160 140
2W 260 270 260 260 260
3W 370 390 375 370 380
6W 600 620 615 600 580
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
AXPR AXPU AXPO AXPC AXPA
1W 150 150 145 160 140
2W 260 270 260 260 260
3W 370 390 375 370
LEGEND:
AXPR – fixture AXP IP65/20 with optics for escape route
AXPU – fixture AXP IP65/20 with universal optics
AXPO – fixture AXP IP65/20 with optics for open area
AXEPR – fixture AXP IP20 with optics for escape route
AXEPU – fixture AXP IP20 with universal optics
AXEPO – fixture AXP IP20 with optics for open area
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
AXPC – fixture AXP IP65/20 with optics for corridor
AXPA – fixture AXP IP65/20 with asymmetric optics optics
AXEPC – fixture AXP IP20 with optics for corridor
AXEPA – fixture AXP IP20 with asymmetric optics optics
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24 VDC
CB – central battery version
CBS – central battery for circuit monitoring
ADP – central battery with ADP address module – SMART technology
ADE – central battery with ADE address module
380
Output in emergency mode of AXP IP20 is the same like AXP IP65/20.Code of IP20 version are indicated in the legend
3
Emergency escape lighting
24
MATERIALS:
Body made of stainless steel or steel painted white,
other colors optionally
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, 3W, 3x1W power LED
Optics
C - corridor
R - escape route
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries 4
INSULATION CLASS:
II or III
IP RATING:
IP20
AMBIENT TEMPERATURE:
t : 0°C - +40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU - Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
Electronic gear and battery package installed in a separate box
80 80
47
DIMENSIONS (mm):
Ø 63mmRECESSING CUT (mm):
h min. 150 mm
• ceiling
220-240VAC
50-60HzIP20
24VDC
LED
LiFePO4
KM 61835 BS-EN
176-275VDC
Ni-Cd
Current list of products with Kitemark and ENEC is available at www.awex.eu
403
195 8
32
44
EYE LED round
O - open area
U – universal
Emergency escape lighting
25
LEGEND:
EYR – fixture EYE LED round with optics for escape route
EYU – fixture EYE LED round with universal optics
EY – fixture EYE LED round without optics
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24 VDC
CB – central battery version
CBS – central battery for circuit monitoring
ADP – central battery with ADP address module – SMART technology
ADE – central battery with ADE address module
ST – stainless steel
WH – fixture in white color
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
EYR EYU
STANDARD
1W C 1 3 SA PT X ST WH
2W C 1 3 SA PT X ST WH
3W C 1 3 SA PT X ST WH
EY 3x1W C 1 3 SA PT X ST WH
PREMIUM
1W B 1 3 SA AT RU ST WH
2W B 1 3 SA AT RU ST WH
3W B 1 3 SA AT RU ST WH
EY 3x1W B 1 3 SA AT RU ST WH
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
1W F CB CBS X ST WH
2W F CB CBS X ST WH
3W F CB CBS X ST WH
EY 3x1W F CB CBS X ST WH
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
1W Z CB ADE ADP ST WH
2W Z CB ADE ADP ST WH
3W Z CB ADE ADP ST WH
EY 3x1W Z CB ADE ADP ST WH
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
1W FZLV ST WH
2W FZLV ST WH
3W FZLV ST WH
EY 3x1W FZLV ST WH
EYO EYC1W E 1 3 SE STPT X WH
EYR EYU
EYO EYC
EYR EYU
EYO EYC
EYR EYU
EYO EYC
EYR EYU
EYO EYC
EYR EYU
EYO EYC
EYO – fixture EYE LED round with optics for open area
EYC – fixture EYE LED round with optics for corridor
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
EYR EYU EY
BASIC
STANDARD
1W 120 140 –
2W 240 240 –
3W 320 360 –
3x1W – – 330
PREMIUM
1W 140 150 –
2W 260 270 –
3W 350 390 –
3x1W – – 360
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
EYR EYU EY
1W 140 150 –
2W 260 270 –
3W 350 390 –
3x1W – – 360
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
EYR EYU EY
1W 140 150 –
2W 260 270 –
3W 350 390 –
3x1W – – 360
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
EYR EYU EY
1W 140 150 –
2W 260 270 –
3W 350 390 –
3x1W – – 360
1W 110 130 –
EYO EYC
EYO EYC
EYO EYC
EYO EYC
125 130
240 240
320 325
– –
135 140
260 260
350 355
– –
125 130
135
260
350
–
140
260
355
–
135
260
350
–
135
260
350
–
140
260
355
–
140
260
355
–
Emergency escape lighting
26
EYE LED square
MATERIALS:
Body made of stainless steel or steel painted white,
other colors optionally
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, 3W, 3x1W power LED
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP20
AMBIENT TEMPERATURE:
t : 0°C - +40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
Electronic gear and battery package installed in a separate box
80
47
80
Ø 63mm
DIMENSIONS (mm):
h min. 150 mm
RECESSING CUT (mm):• ceiling
220-240VAC
50-60HzIP20
24VDC
LED
LiFePO4
KM 61835 BS-EN
176-275VDC
Ni-Cd
Current list of products with Kitemark and ENEC is available at www.awex.eu
403
195 8
32
44
Optics
C - corridor
R - escape route
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
O - open area
U – universal
Emergency escape lighting
27
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
EYKR EYKU
STANDARD
1W C 1 3 SA PT X ST WH
2W C 1 3 SA PT X ST WH
3W C 1 3 SA PT X ST WH
EYK 3x1W C 1 3 SA PT X ST WH
PREMIUM
1W B 1 3 SA AT RU ST WH
2W B 1 3 SA AT RU ST WH
3W B 1 3 SA AT RU ST WH
EYK 3x1W B 1 3 SA AT RU ST WH
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
1W F CB CBS X ST WH
2W F CB CBS X ST WH
3W F CB CBS X ST WH
EYK 3x1W F CB CBS X ST WH
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
1W Z CB ADE ADP ST WH
2W Z CB ADE ADP ST WH
3W Z CB ADE ADP ST WH
EYK 3x1W Z CB ADE ADP ST WH
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
1W FZLV ST WH
2W FZLV ST WH
3W FZLV ST WH
EYK 3x1W FZLV ST WH
EYKO EYKC1W E 1 3 SE STPT X WH
EYKR EYKU
EYKO EYKC
EYKR EYKU
EYKO EYKC
EYKR EYKU
EYKO EYKC
EYKR EYKU
EYKO EYKC
EYKR EYKU
EYKO EYKC
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
EYKR EYKU EYK
BASIC
STANDARD
1W 120 140 –
2W 240 240 –
3W 320 360 –
3x1W – – 330
PREMIUM
1W 140 150 –
2W 260 270 –
3W 350 390 –
3x1W – – 360
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
EYKR EYKU EYK
1W 140 150 –
2W 260 270 –
3W 350 390 –
3x1W – – 360
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
EYKR EYKU EYK
1W 140 150 –
2W 260 270 –
3W 350 390 –
3x1W – – 360
OUTPUT IN EMERGENCY MODE
POWEROUTPUT [lm]
EYKR EYKU EYK
1W 140 150 –
2W 260 270 –
3W 350 390 –
3x1W – – 360
1W 110 130 –
EYKO EYKC
EYKO EYKC
EYKO EYKC
EYKO EYKC
125 130
240 240
320 325
– –
135 140
260 260
350 355
– –
125 130
135
260
350
–
140
260
355
–
135
260
350
–
135
260
350
–
140
260
355
–
140
260
355
–
LEGEND:
EYKR – fixture EYE LED square with optics for escape route
EYKU – fixture EYE LED square with universal optics
EYK – fixture EYE LED square without optics
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24 VDC
CB – central battery version
CBS – central battery for circuit monitoring
ADP – central battery with ADP address module – SMART technology
ADE – central battery with ADE address module
ST – stainless steel
WH – fixture in white color
EYKO – fixture EYE LED square with optics for open area
EYKC – fixture EYE LED square with optics for corridor
Emergency escape lighting
28
MICRO SPOT
White polycarbonate body
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, 3W LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP20
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
III class of insulation of FZLV version
Electronic gear and battery package installed in a separate box
MATERIALS:
220-240VAC
50-60HzIP20
24VDC
LEDDC
Optics:
U - universal
R - escape route
DIMENSIONS (mm):
403
8
32
LIFEPO4
Ni-Cd
176-275V
BASIC: max. 24h
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
Emergency escape lighting
29
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
STANDARD
1W C 1 3 SA X
PREMIUM
1W B 1 3 SA AT RU
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
1W F CB CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
1W Z CB ADE ADP
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM
1W FZLV
LEGEND:
MSR – fixture MICRO SPOT with optics for escape route
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
MSU – fixture MICRO SPOT with universal optic
2W C 1 3 SA XMSU MSR
3W C 1 3 SA X
2W B 1 3 SA AT RUMSU MSR
3W B 1 3 SA AT RU
2W F CB CBS XMSU MSR
3W F CB CBS X
2W Z CB ADE ADPMSU MSR
3W Z CB ADE ADP
2W FZLVMSU MSR
3W FZLV
OUTPUT IN EMERGENCY MODE
POWER
STANDARD
1W 125
PREMIUM
1W 140
OUTPUT IN EMERGENCY MODE
POWER
1W 140
OUTPUT IN EMERGENCY MODE
POWER
1W 140
OUTPUT IN EMERGENCY MODE
POWER
1W 140
OUTPUT [lm]
MSU MSR
120
130
130
130
130
OUTPUT [lm]
MSU MSR
OUTPUT [lm]
MSU MSR
OUTPUT [lm]
MSU MSR
2W 240 230
3W 340 325
2W 265 250
3W 380 360
2W 265 250
3W 380 360
2W 265 250
3W 380 360
2W 265 250
3W 380 360
BASIC
1W E 1 3 SE XMSU MSR
BASIC
1W 125 120
PT
PT
PT
PT
X – fitting without additional options
PT – manual test button
Emergency escape lighting
30
SPY II
White or grey polycarbonate body
MOUNTING:
Inside light fitting
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, 3W LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP20
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
III class of insulation of FZLV version
Electronic gear and battery package installed in a separate box
220-240VAC
50-60HzIP20
24VDC
LED176-275V
LiFePO4
DC
Ni-Cd
MATERIALS:
44 50 - 82
44
DIMENSIONS (mm):
22
134
22
38
Emergency escape lighting
31
LEGEND:
SP2 – fixture SPY II
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – fixture in white color
GR – fixture in grey color
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
STANDARD
1W C 1 3 SA PT X GR WH
SP2 2W C 1 3 SA PT X GR WH
3W C 1 3 SE PT X GR WH
PREMIUM
1W B 1 3 SA AT RU GR WH
SP2 2W B 1 3 SA AT RU GR WH
3W B 1 3 SE AT RU GR WH
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
1W F CB CBS X GR WH
SP2 2W F CB CBS X GR WH
3W* F CB CBS X GR WH
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE:
CODE POWER MODULE SYSTEM OPTIONS COLOR
1W Z CB ADE ADP GR WH
SP2 2W Z CB ADE ADP GR WH
3W* Z CB ADE ADP GR WH
FZLV SYSTEM CONFIGURATION:
CODE POWER SYSTEM COLOR
1W FZLV GR WH
SP2 2W FZLV GR WH
3W* FZLV GR WH
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
STANDARD
1W 140
2W 250
3W 360
PREMIUM
1W 150
2W 270
3W 390
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
1W 150
2W 270
3W 390
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
1W 150
2W 270
3W 390
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
1W 150
2W 270
3W 390
*only non maintained
BASIC
1W E 1 3 SE PT X GR WH
BASIC
1W 140SP2
E – electronic gear for BASIC self-contained fittings
Emergency escape lighting
32
MATERIALS:
White polycarbonate body
Transparent or opal polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, 3W, 3x1W, 6x1W power LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP42 or IP65
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°C a
t : -25°C ÷ 40°C – together with heater for low temperatures a
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
Protection against mechanical impacts – IK08
III class of insulation of FZLV version
IP4224VDC
IP65LED220-240V
AC50-60Hz
79356
13
6
DIMENSIONS (mm):
LiFePO4
KM 61835 BS-EN
176-275VDC
Ni-Cd
Current list of products with Kitemark and ENEC is available at www.awex.eu
HELIOS LED
RW – RUBIC UNA Wireless central monitoring
BASIC: max. 24h
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
Emergency escape lighting
33
SA – maintained (with an option of connecting as non-maintained)
LEGEND:
HWM – fixture Helios IP65, assembly altitudes: 2,5 – 10 m
HWEM – fixture Helios IP42, assembly altitudes: 2,5 – 10 m
HWD – fixture Helios IP65, assembly altitudes: 8 – 14m
HWED – fixture Helios IP42, assembly altitudes: 8 – 14m
HHP – fixture Helios IP65 6x1W assembly altitudes: 2,5 – 14m
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
PT – manual test button
X – fitting without additional options
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COVER
STANDARD
1W C 1 3 SA PT X TR OP
HWD HWED 3x1W C 1 3 SA PT X TR
HHP 6x1W* B 1 3 SA PT X TR
PREMIUM
1W B 1 3 SA TR OP
HWD HWED 3x1W B 1 3 SA TR
HHP 6x1W* B 1 3 SA TR
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COVER
1W F CB CBS X TR OP
HWD HWED 3x1W F CB CBS X TR
HHP 6x1W F CB CBS X TR
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COVER
OUTPUT IN EMERGENCY MODE
POWER *OUTPUT [lm]
STANDARD
1W 120
3x1W 340
6x1W 920
PREMIUM
1W 130
3x1W 370
6x1W 920
OUTPUT IN EMERGENCY MODE
POWER *OUTPUT [lm]
1W 130
3x1W 370
6x1W 920
OUTPUT IN EMERGENCY MODE
POWER *OUTPUT [lm]
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COVER
1W FZLV TR OP
HWD HWED 3x1W FZLV TR
HHP 6x1W FZLV TR
OUTPUT IN EMERGENCY MODE
POWER *OUTPUT [lm]
1W 130
3x1W 370
6x1W 920
BASIC
HWM HWEM 1W E 1 SE PT X TR OP
BASIC
1W 1203
HWM HWEM 2W C 1 3 SA PT X TR OP 2W 220
3W C 1 3 SA PT X TR OP 3W 330
HWM HWEM 2W B 1 3 SA
3W B 1 3 SA
2W 240
3W 360
AT RU
AT RU
AT RU
AT RU
AT RU
RW
RW
RW
RW
RW
HWM HWEM 2W F CB CBS X
3W F CB CBS X
2W 240
3W 360
1W Z CB TR OP
HWD HWED 3x1W Z CB TR
HHP 6x1W Z CB TR
1W 130
3x1W 370
6x1W 920
HWM HWEM 2W Z CB
3W Z CB
2W 240
3W 360
ADE ADP
ADE ADP
ADE ADP
ADE ADP
ADE ADP
HWM HWEM 2W FZLV TR
3W FZLV TR
2W 240
3W 360
ADP – central battery with ADP address module – SMART technology
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
FZLV – central battery FZLV 24 VDC
TR – transparent polycarbonate cover
OP – opal polycarbonate cover
RW – RUBIC UNA Wireless central monitoring
* power in emergency mode
OP
OP
E – electronic gear for BASIC self-contained fittings
TR OP
RW TR OP
TR OP
TR OP
TR OP
TR OP
*light Output value for transparent cover only
Emergency escape lighting
34
MATERIALS:
White polycarbonate body
Transparent polycarbonate cover with Fresnel optics
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC
LIGHT SOURCE:
8W, 11W, 18W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h or 3h , Ni-Cd 3,6V batteries
INSULATION CLASS:
II
IP RATING:
IP42 or IP65
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
t : -25°C ÷ 40°C – together with heater for low temperatures a
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
Protection against mechanical impacts – IK08
79356
13
6
IP42 G5
T5 IP65
TC-SEL 2G7
176-275VDC
220-240VAC
50-60Hz
HELIOS
DIMENSIONS (mm):
Ni-Cd
Current list of products with Kitemark and ENEC is available at www.awex.eu
KM 61835 BS-EN
Emergency escape lighting
35
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
8W T 1 3 SE SA
H HE 11W T 1 3 SE SA
18W T 1 3 SE
PT AT
PT AT
PT AT
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
8W T CB
H HE 11W T CB
18W T CB
CBS X
CBS X
CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
8W T CB
H HE 11W T CB
18W T CB
ADL ADS
ADL ADS
ADL ADS
LEGEND:
H – fixture Helios IP 65
HE – fixture Helios IP 42
T – electronic gear for LFL fittings
SE – non-maintained
SA – maintained
PT – manual test button
X – fitting without additional options
AT – autotest
CB – central battery version
CBS – central battery for circuit monitoring
ADL – central battery with ADL module
ADS – central battery with ADS address module – SMART technology
Emergency escape lighting
36
MATERIALS:
Black, hit resistant polycarbonate
POWER SUPPLY:
230 VAC/50Hz optionally – 12 VDC
LIGHT SOURCE:
3W (120 lm) highpower LED
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
8,5h 6V / 4,0 Ah batteries
INSULATION CLASS:
II
IP RATING:
IP43
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Charging through wall mounted adapter or directly from mains 230V
IP43
230VAC
50-60Hz
SELF CONTAINED CONFIGURATION
CODE POWER [W] MODULE AUTONOMY [h]
JOBLED 3 Z 8,5
Ø13080
13
0
29
0
55
13
21
12
128
DCLED
DIMENSIONS (mm):
JOBLED
Emergency escape lighting
37
MATERIALS:
White polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
Optional assembly in dry-wall or under plastering
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC
LIGHT SOURCE:
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h or 3h , Ni-Cd 3,6V batteries
INSULATION CLASS:
II
IP RATING:
IP22
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
LEGEND:
TG – fixture Tiger
T – electronic gear for LFL fittings
SE – non-maintained
SA – maintained
PT – manual test button
X – fitting without additional options
AT – autotest
CB – central battery version
CBS – central battery for circuit monitoring
ADL – central battery with ADL module
ADS – central battery with ADS address module – SMART technology
IP22 G5
T5
Ni-Cd
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTHONOMY [h] MODE OPTIONS
TG 8W T 1 3 SE SA PT AT
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
TG 8W T CB CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
TG 8W T CB ADL ADS
DC
11
8
350
323
14
4
DIMENSIONS (mm):
220-240VAC
50-60Hz
TIGER
176-275V
325 x 120
RECESSING CUT (mm):
• wall• ceiling
Current list of products with Kitemark and ENEC is available at www.awex.eu
KM 61835 BS-EN
Emergency escape lighting
38
MATERIALS:
White polycarbonate body
Transparent or opal polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
Optional assembly in dry-wall or under plastering
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, 3W LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP22
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
III class of insulation of FZLV version
TIGER LED
11
8
350
323
14
4
DIMENSIONS (mm):
220-240VAC
50-60HzIP22
24VDC
LED176-275V
DC
LiFePO4
Ni-Cd
BASIC: max. 24h
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
325 x 120
RECESSING CUT (mm):
• wall• ceiling
Emergency escape lighting
39
LEGEND:
TL – fixture Tiger LED
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
TR – transparent polycarbonate cover
OP – opal polycarbonate cover
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COVER
STANDARD
1W C 1 3 SA PT X TR OP
PREMIUM
1W B 1 3 SA AT RU TR OP
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COVER
3W F CB CBS X TR OP
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COVER
3W Z CB ADE ADP TR OP
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COVER
1W FZLV TR OP
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
STANDARD
1W 120
PREMIUM
1W 135
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
3W 380
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
3W 380
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
1W
TL 2W C 1 3 SA PT X TR OP 2W 230
3W C 1 3 SA PT X TR OP 3W 340
TL 2W B 1 3 SA AT RU TR OP 2W 250
3W B 1 3 SA AT RU TR OP 3W 380
1W F CB CBS X TR OP 1W 135
TL 2W F CB CBS X TR OP 2W 250
1W Z CB ADE ADP TR OP 1W 135
TL 2W Z CB ADE ADP TR OP 2W 250
TL 2W FZLV TR OP 2W
3W FZLV TR OP 3W 380
135
250
BASIC
1W E 1 3 SE PT X TR OP
BASIC
1W 120TL
E – electronic gear for BASIC self-contained fittings
Emergency escape lighting
40
MATERIALS:
Stainless steel painted white, grey or black
MOUNTING:
Surface (wall)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3x1W LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
I or III
IP RATING:
IP66
AMBIENT TEMPERATURE:
t : 0°C - +40°Ca
t : -25°C ÷ 40°C – together with heater for low temperaturesa
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
Optional adaptation of the fixture for low temperatures up to -25°C
Protection against mechanical impacts – IK10
222
227
77
DIMENSIONS (mm):
2424VVDCDC
LEDLED220-240V
AC50-60Hz
Ni-Cd
176-275VDC
IP66
LiFePO4
OUTDOOR LED
Current list of products with Kitemark and ENEC is available at www.awex.eu
Emergency escape lighting
41
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
STANDARD
ODB 3x1W C 1 3 SA PT X
PREMIUM
ODB 3x1W B 1 3 SA AT RU
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
ODB 3x1W F CB CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
ODB 3x1W Z CB ADE ADP
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM
ODB 3x1W FZLV
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
STANDARD
3x1W 330
PREMIUM
3x1W 360
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
3x1W 360
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
3x1W 360
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
3x1W 360
LEGEND:
ODB – fixture Outdoor LED
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test buttonX – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH GR BL
WH GR BL
COLOR
COLOR
WH GR BL
COLOR
WH GR BL
COLOR
WH GR BL
WH – fixture in white color
GR – fixture in grey color
BL – fixture in black color
Emergency escape lighting
42
MATERIALS:
White polycarbonate body
Transparent polycarbonate cover with lens
MOUNTING:
Surface (wall, ceiling)
Optional recessed (ceiling**)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3W LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP44
AMBIENT TEMPERATURE:
t : 0°C - +40°Ca
OPTIONS:
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RW – RUBIC UNA Wireless central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
**requires an accessory for recessed mounting, RW option not available
Current list of products with Kitemark and ENEC is available at www.awex.eu
325 41
25
0
16
0
20310
DIMENSIONS (mm):
220-240VAC
50-60Hz
24VDC
LED
Ni-Cd
KM 61835 BS-EN
176-275VDC
IP44
LiFePO4
*see pictogram
*1pc. of universal pictogram is included in each single box
SK-8
RU – Rubic UNA central monitoring
350 x 60
RECESSING CUT (mm):
• ceiling
Emergency escape lighting
43
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
STANDARD
SK-8 3W C 1 3 SA PT X WT
PREMIUM
SK-8 3W B 1 3 SA WT
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
SK-8 3W F CB CBS X WT
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
SK-8 3W Z CB ADE ADP WT
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
SK-8 3W FZLV WT
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
STANDARD
3W 100
PREMIUM
3W 120
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
3W 120
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
3W 120
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
3W 120
LEGEND:
SK8 – fixture SK-8
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WT – white body and transparent cover
AT RU RW
RW – RUBIC UNA Wireless central monitoring
Emergency escape lighting
44
MATERIALS:
White, grey or black polycarbonate body
Plexi glass
MOUNTING:
Surface (wall)
Optionally recessed (wall**)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3W LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP40
AMBIENT TEMPERATURE:
t : 0°C - +40°Ca
OPTIONS:
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU - Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
Fixture with floor illumination system
**requires an accessory – concrete box, RW option not available
337 57
37
18
9
72
DIMENSIONS (mm):
DC
220-240VAC
50-60Hz
24VDC
LED IP40
Ni-Cd LiFePO4
*see pictogram
INFINITY II
RW – RUBIC UNA Wireless central monitoring
KM 61835 BS-EN
Current list of products with Kitemark and ENEC is available at www.awex.eu
*1pc. of universal pictogram is included in each single box
INFINITY II B INFINITY II AW INFINITY II AC INFINITY II AL
176-275V
Emergency escape lighting
45
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
STANDARD
IF2BWD IF2AWD IF2ACD IF2ALD 3W C 1 3 SA PT X WH GR BL
PREMIUM
IF2BWD IF2AWD IF2ACD IF2ALD 3W B 1 3 SA WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
IF2BWD IF2AWD IF2ACD IF2ALD 3W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
IF2BWD IF2AWD IF2ACD IF2ALD 3W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
IF2BWD IF2AWD IF2ACD IF2ALD 3W FZLV WH GR BL
*Output in emergency mode of IF2AWD, IF2ACD, IF2ALD is the same like IF2BWD
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
STANDARD
3W 70
PREMIUM
3W 80
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
3W 80
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
3W 80
OUTPUT IN EMERGENCY MODE
POWER OUTPUT [lm]
3W 80
LEGEND:
IF2BWD – fixture INFINITY II B one side with floor illumination
IF2AWD – fixture INFINITY II AW two side with floor illumination
IF2ACD – fixture INFINITY II AC two side with floor illumination
IF2ALD – fixture INFINITY II AL two side with floor illumination
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RW – RUBIC UNA Wireless central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24VDC
AT RU RW
RU – RUBIC UNA central monitoring
WH – white color
GR – grey color
BL – black color
Emergency escape lighting
46
EDGE R
White polycarbonate body
Opal polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC
LIGHT SOURCE - MAINS MODE:
CHARGING:
AUTONOMY AND BATTERIES:
INSULATION CLASS:
II
IP RATING:
IP54
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
MATERIALS:
OPTIONS:
SA – LED emergency section - maintained (night mode)
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
Optional fixtures with MCR motion sensor
BASIC: max. 24hPREMIUM: max. 12h; energy-saving electronic charger
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO4 6,4V batteries
Power: 12W, 18W, 24W LED
Color Temperature: 3000K, 4000K
Optionally pendant* (ceiling)
*requires an accessory for pendant mounting
LIGHT SOURCE - MERGENCY MODE:E
Power: 1W, 3W LED
Color Temperature: 6500K
220-240V
50-60Hz
176-275VIP54
Ni-Cd
SE – LED emergency section - non maintained
63280
28
0
DIMENSIONS (mm):
RW – RUBIC UNA Wireless central monitoring
Color Temperature in emergency mode: 6500K
Current list of products with Kitemark and ENEC is available at www.awex.eu
Emergency escape lighting
47
MAINS MODE CONFIGURATION
CODE DETECTION
EDRE12EDRE18EDRE24
WH WS 3000 4000
WH WS 3000 4000
WH WS 3000 4000
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER* MODULE SYSTEM OPTION DETECTION
EDRE12 EDRE18 EDRE241W F CB CBS X WH 3000 4000
3W F CB CBS X WH 3000 4000
EDRE12 12W X CB CBS X WH 3000 4000
EDRE18 18W X CB CBS X WH 3000 4000
EDRE24 24W X CB CBS X WH 3000 4000
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER* MODULE SYSTEM OPTION DETECTION
EDRE12 EDRE18 EDRE241W Z CB ADP WH WS 3000 4000
3W Z CB ADP WH WS 3000 4000
EDRE12 12W X CB ADS WH WS 3000 4000
EDRE18 18W X CB ADS WH WS 3000 4000
EDRE24 24W X CB ADS WH WS 3000 4000
SELF-CONTAINED CONFIGURATION
CODE POWER* MODULE AUTONOMY [h] MODE OPTION DETECTION
BASIC
EDRE12 EDRE18 EDRE24 1W E 1 3 SE WH WS 3000 4000
PREMIUM
EDRE12 EDRE18 EDRE24 3W B 1 3 SA AT RU RW WH WS 3000 4000
MAINS MODE
CODEOUTPUT [lm]
3000K 4000K
EDRE12EDRE18EDRE24
1325 1425
2080 2235
2500 2690
CENTRAL BATTERY MODE
POWER*OUTPUT [lm]
3000K 4000K 6500K
1W X X 115
3W X X 315
12W 1325 1425 X
18W 2080 2235 X
24W 2500 2690 X
CENTRAL BATTERY MODE
3000K 4000K 6500K
1W X X 115
3W X X 315
12W 1325 1425 X
18W 2080 2235 X
24W 2500 2690 X
EMERGENCY MODE
POWER*
BASIC
1W 105
PREMIUM
3W
POWER*
LEGEND:
B – electronic gear for PREMIUM self-contained fittings
E – electronic gear for BASIC self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
ADS – central battery with ADS address module – SMART technology
ADP – central battery with ADP address module – SMART technology
SE – LED emergency section - non maintained
SA – LED emergency section - maintained (night )mode
AT – autotest
PT – manual test button
RU – RUBIC UNA central monitoring
RW – RUBIC UNA Wireless central monitoring
CB – central battery system
CBS – central battery for circuit monitoring
WH – fitting without motion sensor MCR
WS – fitting with motion sensor MCR
3000 – LED color temperature K
4000 – LED color temperature K
EDRE12 – fitting EDGE R 12W in maintained mode
EDRE18 – fitting EDGE R 18W in maintained mode
EDRE24 – fitting EDGE R 24W in maintained mode
* – power in emergency mode
COLOR
TEMPERATURE
COLOR
TEMPERATURE
COLOR
TEMPERATURE
COLOR
TEMPERATURE
OUTPUT [lm]
OUTPUT [lm]
315
X – fitting without additional options
PT X
Emergency escape lighting
48
EDGE S
DIMENSIONS (mm):
63280
28
0
White polycarbonate body
Opal polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC
LIGHT SOURCE - MAINS MODE:
CHARGING:
AUTONOMY AND BATTERIES:
INSULATION CLASS:
II
IP RATING:
IP54
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
MATERIALS:
OPTIONS:
SA – LED emergency section - maintained ( )night mode
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
Optional fixtures with MCR motion sensor
BASIC: max. 24hPREMIUM: max. 12h; energy-saving electronic charger
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO4 6,4V batteries
Power: 12W, 18W, 24W LED
Color Temperature: 3000K, 4000K
Optionally pendant** (ceiling)
*requires an accessory for recessed mounting, RW option not available
LIGHT SOURCE - MERGENCY MODE:E
Power: 1W, 3W LED
Color Temperature: 6500K
SE – LED emergency section - non maintained
220-240V
50-60Hz
176-275VIP54
Ni-Cd
Optional recessed* (ceiling)
**requires an accessory for pendant mounting
RW – RUBIC UNA Wireless central monitoring
Current list of products with Kitemark and ENEC is available at www.awex.eu
Color Temperature in emergency mode: 6500K
310 x 310
RECESSING CUT (mm):
• wall• ceiling
Emergency escape lighting
49
MAINS MODE CONFIGURATION
CODE DETECTION
EDSE12EDSE18EDSE24
WH WS 3000 4000
WH WS 3000 4000
WH WS 3000 4000
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER* MODULE SYSTEM OPTION DETECTION
EDSE12 EDSE18 EDSE241W F CB CBS X WH 3000 4000
3W F CB CBS X WH 3000 4000
EDSE12 12W X CB CBS X WH 3000 4000
EDSE18 18W X CB CBS X WH 3000 4000
EDSE24 24W X CB CBS X WH 3000 4000
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER* MODULE SYSTEM OPTION DETECTION
EDSE12 EDSE18 EDSE241W Z CB ADP WH WS 3000 4000
3W Z CB ADP WH WS 3000 4000
EDSE12 12W X CB ADS WH WS 3000 4000
EDSE18 18W X CB ADS WH WS 3000 4000
EDSE24 24W X CB ADS WH WS 3000 4000
SELF-CONTAINED CONFIGURATION
CODE POWER* MODULE AUTONOMY [h] MODE OPTION DETECTION
BASIC
EDSE12 EDSE18 EDSE24 1W E 1 3 SE WH WS 3000 4000
PREMIUM
EDSE12 EDSE18 EDSE24 3W B 1 3 SA SE AT RU RW WH WS 3000 4000
MAINS MODE
CODEOUTPUT [lm]
3000K 4000K
EDSE12EDSE18EDSE24
1325 1425
2080 2235
2500 2690
CENTRAL BATTERY MODE
POWER*OUTPUT [lm]
3000K 4000K 6500K
1W X X 115
3W X X 315
12W 1325 1425 X
18W 2080 2235 X
24W 2500 2690 X
CENTRAL BATTERY MODE
3000K 4000K 6500K
1W X X 115
3W X X 315
12W 1325 1425 X
18W 2080 2235 X
24W 2500 2690 X
EMERGENCY MODE
POWER*
BASIC
1W 105
PREMIUM
3W
POWER*
LEGEND:
B – electronic gear for PREMIUM self-contained fittings
E – electronic gear for BASIC self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
ADS – central battery with ADS address module – SMART technology
ADP – central battery with ADP address module – SMART technology
SE – LED emergency section - non maintained
SA – LED emergency section - maintained (night )mode
AT – autotest
PT – manual test button
RU – RUBIC UNA central monitoring
RW – RUBIC UNA Wireless central monitoring
CB – central battery system
CBS – central battery for circuit monitoring
WH – fitting without motion sensor MCR
WS – fitting with motion sensor MCR
3000 – LED color temperature K
4000 – LED color temperature K
EDSE12 – fitting EDGE S 12W in maintained mode
EDSE18 – fitting EDGE S 18W in maintained mode
EDSE24 – fitting EDGE S 24W in maintained mode
* – power in emergency mode
COLOR
TEMPERATURE
COLOR
TEMPERATURE
COLOR
TEMPERATURE
COLOR
TEMPERATURE
OUTPUT [lm]
OUTPUT [lm]
315
PT X
emergency exit signS
ARROW N
TWINS PLEXI LED
QUADRO
EXIT S
HELIOS & HELIOS LED
ESCAPE LED
INFINITY II AW
HELIOS DS& HELIOS DS LED
ARROW P INFINITY II AC & INFINITY II AL
INFINITY II B
SCREEN SCREEN DSTIGER & TIGER LED
TIGER DS& TIGER DS LED
SK-8
52ARROW P 54EXIT S EXIT M 58EXIT L 60INFINITY II AW 62INFINITY II AC & INFINITY II AL INFINITY II B SK-8 68TWINS 70PLEXI LED 72ESCAPE LED 74HELIOS & HELIOS LED 76HELIOS DS & HELIOS DS LED 78TIGER & TIGER LED 80TIGER DS & TIGER DS LED 82SCREEN 84
ARROW N
56
6466
SCREEN DS 86QUADRO 88
EXIT M EXIT L
emergency exit signs
52
ARROW N
MATERIALS:
White, grey or black polycarbonate body
Plexi glass
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP40
VIEWING DISTANCE:
25m
AMBIENT TEMPERATURE:
t : 0°C - +40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
*1pc. of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
*see pictogram
220-240VAC
50-60Hz
24VDC
LED
Ni-Cd
176-275VDC
LiFePO4
IP40
KM 61835 BS-EN
299
250
20
6
12
5
43
DIMENSIONS (mm):
Optionally mounting on a rope sling (ceiling*)
*requires an accessory for mounting on a rope sling
emergency exit signs
53
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
ARN 1W E 1 3 SE PT X WH GR BL
STANDARD
ARN1W C 1 3 SA PT X WH GR BL
2W C 1 3 SA PT X WH GR BL
PREMIUM
1W B 1 3 SA AT RU WH GR BLARN
2W B 1 3 SA AT RU WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
ARN1W F CB CBS X WH GR BL
2W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
ARN1W Z CB ADE ADP WH GR BL
2W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
1W FZLV WH GR BLARN
2W FZLV WH GR BL
LEGEND:
ARN – fixture ARROW N
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
BL – black color
emergency exit signs
54
ARROW P
MATERIALS:
White, grey or black polycarbonate body
Plexi glass
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP40
VIEWING DISTANCE:
25m
AMBIENT TEMPERATURE:
t : 0°C - +40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
*see pictogram
DIMENSIONS (mm):
328
20
6
250 612
5
62
220-240VAC
50-60Hz
24VDC
LED
Ni-Cd
176-275VDC
LiFePO4
KM 61835 BS-EN
IP40
300 x 45
RECESSING CUT (mm):
• ceiling
emergency exit signs
55
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
ARP 1W E 1 3 SE PT X WH GR BL
STANDARD
1W C 1 3 SA PT X WH GR BLARP
2W C 1 3 SA PT X WH GR BL
PREMIUM
1W B 1 3 SA AT RU WH GR BLARP
2W B 1 3 SA AT RU WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
ARP1W F CB CBS X WH GR BL
2W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE:
CODE POWER MODULE SYSTEM OPTIONS COLOR
ARP1W Z CB ADE ADP WH GR BL
2W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION:
CODE POWER SYSTEM COLOR
1W FZLV WH GR BLARP
2W FZLV WH GR BL
LEGEND:
ARP – fixture ARROW P
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
BL – black color
emergency exit signs
56
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
White, gray or black polycarbonate body
Transparent polycarbonate cover
Plexi glass
MOUNTING:
Surface (wall, ceiling**)
Optionally recessed*** (wall, ceiling**)
Optionally pendant**** (ceiling**)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP65
VIEWING DISTANCE:
20 m
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
t : -25°C ÷ 40°C – together with heater for low temperaturesa
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
III class of insulation of FZLV version
**additional plexi for two-sided emergency exit signs
***requires an accessory for recessed mounting, RW option not available
****requires an accessory for pendant mounting
*see pictogramKM 61835 BS-EN
EXIT S
MATERIALS:
RW – RUBIC UNA Wireless central monitoring
220-240V
AC50-60Hz
24VDC
LEDDC
IP65
Ni-CdLiFePO4
DIMENSIONS (mm):
RECESSING CUT (mm):• wall• ceiling
226
12
5
42
209 107
15
0
176-275V
d=20m
emergency exit signs
57
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
ETS 1W E 1 3 SE PT X WH GR BL
STANDARD
ETS1W C 1 3 SA PT X WH GR BL
2W C 1 3 SA PT X WH GR BL
PREMIUM
1W B 1 3 SA WH GR BLETS
2W B 1 3 SA WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
ETS 1W F CB CBS X WH GR BL
ETS 2W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
ETS 1W Z CB ADE ADP WH GR BL
ETS 2W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
ETS1W FZLV WH GR BL
2W FZLV WH GR
LEGEND:
ETS – fitting EXIT S
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
BL – black color
AT RWRU
AT RWRU
RW – RUBIC UNA Wireless central monitoring
BL
emergency exit signs
58
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
White, gray or black polycarbonate body
Transparent polycarbonate cover
Plexi glass
MOUNTING:
Surface (wall, ceiling**)
Optionally recessed*** (wall, ceiling**)
Optionally pendant**** (ceiling**)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP65
VIEWING DISTANCE:
25 m
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
t : -25°C ÷ 40°C – together with heater for low temperaturesa
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
III class of insulation of FZLV version
**additional plexi for two-sided emergency exit signs
***requires an accessory for recessed mounting, RW option not available
****requires an accessory for pendant mounting
220-240V
AC50-60Hz
24VDC
LED
*see pictogram
DIMENSIONS (mm):
RECESSING CUT (mm):• wall• ceiling
259
17
5
260 125
44
276
12
5
14
3
260
176-275VDC
IP65
KM 61835 BS-EN
Ni-CdLiFePO4
EXIT M
MATERIALS:
RW – RUBIC UNA Wireless central monitoring
emergency exit signs
59
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
ETE 1W E 1 3 SE PT X WH GR BL
STANDARD
ETE1W C 1 3 SA PT X WH GR BL
2W C 1 3 SA PT X WH GR BL
PREMIUM
ETE1W B 1 3 SA WH GR BL
2W B 1 3 SA WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
1W F CB CBS X WH GR BLETE
2W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
1W Z CB ADE ADP WH GR BLETE
2W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
1W FZLV WH GR BLETE
2W FZLV WH GR
LEGEND:
ETE – fitting EXIT M
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
BL – black color
AT RWRU
AT RWRU
RW – RUBIC UNA Wireless central monitoring
BL
emergency exit signs
60
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
White, gray or black polycarbonate body
Transparent polycarbonate cover
Plexi glass
MOUNTING:
Surface (wall, ceiling**)
Optionally recessed*** (wall, ceiling**)
Optionally pendant**** (ceiling**)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery –220÷240VAC/50÷60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP65
VIEWING DISTANCE:
30 m
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
t : -25°C ÷ 40°C – together with heater for low temperaturesa
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
III class of insulation of FZLV version
**additional plexi for two-sided emergency exit signs
***requires an accessory for recessed mounting, RW option not available
****requires an accessory for pendant mounting
220-240V
AC50-60Hz
24VDC
LED
*see pictogram
DIMENSIONS (mm):
RECESSING CUT (mm):• wall• ceiling
176-275VDC
IP65
KM 61835 BS-EN
EXIT L
MATERIALS:
RW – RUBIC UNA Wireless central monitoring
306 152
20
7
332
17
8
52
Ni-CdLiFePO4
d=30m
emergency exit signs
61
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
ETL 1W E 1 3 SE PT X WH GR BL
STANDARD
ETL1W C 1 3 SA PT X WH GR BL
2W C 1 3 SA PT X WH GR BL
PREMIUM
ETL1W B 1 3 SA WH GR BL
2W B 1 3 SA WH GR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
1W F CB CBS X WH GR BLETL
2W F CB CBS X WH GR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
1W Z CB ADE ADP WH GR BLETL
2W Z CB ADE ADP WH GR BL
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
1W FZLV WH GR BLETL
2W FZLV WH GR
LEGEND:
ETL – fitting EXIT L
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring system
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
BL – black color
AT RWRU
AT RWRU
RW – RUBIC UNA Wireless central monitoring
BL
emergency exit signs
62
INFINITY II AW
MATERIALS:
White, grey or black polycarbonate body
Plexi glass
MOUNTING:
Surface (wall)
Optionally recessed (wall**)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W ,2W LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP40
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
t : 0°C - + 40°Ca
OPTIONS:
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
**requires an accessory - concrete box, RW option not available
*see pictogram
33740
23
2
DIMENSIONS (mm):
220-240VAC
50-60Hz
24VDC
LED IP40176-275V
DC
Ni-Cd LiFePO4
RW – RUBIC UNA Wireless central monitoring
72
INF
INIT
Y I
I A
W
d=30m
KM 61835 BS-EN
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
260 x 80
RECESSING CUT (mm):
• wall
emergency exit signs
63
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
STANDARD
IF2AWS1W C 1 3 SA PT X WH GR
2W C 1 3 SA PT X WH GR
1W B 1 3 SA WH GRIF2AWS
2W B 1 3 SA WH GR
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
IF2AWS1W F CB CBS X WH GR
2W F CB CBS X WH GR
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
IF2AWS1W Z CB ADE ADP WH GR
2W Z CB ADE ADP WH GR
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
1W FZLV WH GRIF2AWS
2W FZLV WH
LEGEND:
IF2AWS – fixture INFINITY II AW
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
BL
BL
BL
BL
BL
BL
BL
BLGR
RW – RUBIC UNA Wireless central monitoring
BL – black color
AT RWRU
AT RWRU
BL
BL
PREMIUM
emergency exit signs
64
INFINITY II AC & INFINITY II AL
White, grey or black polycarbonate body
Plexi glass
MOUNTING:
Surface (ceiling, rope sling)
Optionally recessed (ceiling**)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP40
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
OPTIONS:
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
**requires an accessory for recessed mounting, RW option not available
*see pictogram
DIMENSIONS (mm):
220-240VAC
50-60Hz
24VDC
LED IP40
d=30m
176-275VDC
Ni-Cd LiFePO4
MATERIALS:
RW – RUBIC UNA Wireless central monitoring 337 20
72232
337
ma
x 1
m
INF
INIT
Y I
I A
LIN
FIN
ITY
II
AC
KM 61835 BS-EN
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
emergency exit signs
65
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
STANDARD
1W C 1 3 SA PT X WH GRIF2ACS IF2ALS
2W C 1 3 SA PT X WH GR
PREMIUM
1W B 1 3 SA WH GRIF2ACS IF2ALS
2W B 1 3 SA WH GR
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
1W F CB CBS X WH GRIF2ACS IF2ALS
2W F CB CBS X WH GR
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
IF2ACS IF2ALS1W Z CB ADE ADP WH GR
2W Z CB ADE ADP WH GR
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
IF2ACS IF2ALS1W FZLV WH GR
2W FZLV WH
LEGEND:
IF2ACS – fixture INFINITY II AC
IF2ALS – fixture INFINITY II AL
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
AT RWRU
AT RWRU
GR
RW – RUBIC UNA Wireless central monitoring
BL – black color
emergency exit signs
66
INFINITY II B
White, grey or black polycarbonate body
Plexi glass
MOUNTING:
Surface (wall)
Optionally recessed (wall**)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP40
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
t : 0°C - + 40°Ca
OPTIONS:
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU - Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
**requires an accessory - concrete box, RW option not available
*see pictogram
220-240VAC
50-60Hz
24VDC
LED IP40
DIMENSIONS (mm):
DC
Ni-Cd LiFePO4
MATERIALS:
RW – RUBIC UNA Wireless central monitoring
337 57
37
18
9
72
INF
INIT
Y I
I B
d=30m
KM 61835 BS-EN
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
176-275V
emergency exit signs
67
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
STANDARD
IF2BWS1W C 1 3 SA PT X WH GR
2W C 1 3 SA PT X WH GR
PREMIUM
IF2BWS1W B 1 3 SA WH GR
2W B 1 3 SA WH GR
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
IF2BWS1W F CB CBS X WH GR
2W F CB CBS X WH GR
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
IF2BWS1W Z CB ADE ADP WH GR
2W Z CB ADE ADP WH GR
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
IF2BWS1W FZLV WH GR
2W FZLV WH
LEGEND:
IF2BWS – fixture INFINITY II B
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
AT RWRU
AT RWRU
GR
RW – RUBIC UNA Wireless central monitoring
BL – black color
emergency exit signs
68
MATERIALS:
White polycarbonate body
Opal polycarbonate cover
MOUNTING:
Surface (ceiling, wall)
Optional recessed (ceiling**)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP44
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
**requires an accessory for recessed mounting, RW option not available
325 41
25
0
16
0
20310
DIMENSIONS (mm):
220-240VAC
50-60Hz
24VDC
LED
Ni-Cd
KM 61835 BS-EN
176-275VDC
IP44
*see pictogram
LiFePO4
d=30m
SK-8
RW – RUBIC UNA Wireless central monitoring
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
350 x 60
RECESSING CUT (mm):
• ceiling
emergency exit signs
69
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
SK8 1W E 1 3 SE PT X WL
STANDARD
SK81W C 1 3 SA PT X WL
2W C 1 3 SA PT X WL
PREMIUM
SK81W B 1 3 SA WL
2W B 1 3 SA WL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
SK81W F CB CBS X WL
2W F CB CBS X WL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
SK81W Z CB ADE ADP WL
2W Z CB ADE ADP WL
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
SK81W FZLV WL
2W FZLV
LEGEND:
SK8 – fixture SK-8
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WL – white body and opal cover
RW – RUBIC UNA Wireless central monitoring
AT RWRU
AT RWRU
WL
emergency exit signs
70
MATERIALS:
Silver or black aluminium body
Plexi glass
MOUNTING:
Surface (wall, ceiling)
Optionally mounting on a rope sling (ceiling*)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
I or III
IP RATING:
IP41
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
t : 0°C - +40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
AT – autotest
PT – manual test button
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
24VDC
LED
Ni-Cd
*see pictogram
48315
24
3
83
16
0
DIMENSIONS (mm):
176-275VDC
IP41
LiFePO4
KM 61835 BS-EN
220-240VAC
50-60Hz
d=30m
TWINS
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
*requires an accessory for mounting on a rope sling
emergency exit signs
71
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
TW 1W E 1 3 SE PT X SR BL
STANDARD
TW1W C 1 3 SA PT X SR BL
2W C 1 3 SA PT X SR BL
PREMIUM
TW1W B 1 3 SA AT RU SR BL
2W B 1 3 SA AT RU SR BL
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
1W F CB CBS X SR BLTW
2W F CB CBS X SR BL
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
TW1W Z CB ADE ADP SR BL
2W Z CB ADE ADP SR BL
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
1W FZLV SR BLTW
2W FZLV SR BL
LEGEND:
TW – fixture TWINS
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
SR – silver color
BL – black color
emergency exit signs
72
MATERIALS:
Steel body in grey or white color
Plexi glass
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
I or III
IP RATING:
IP20
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
24VDC
LED
Ni-Cd
325
21
0
45
355 110
17
0
315
16
0
DIMENSIONS (mm):
DCIP20
LiFePO4
220-240VAC
50-60Hz
d=30m
*see pictogramKM 61835 BS-EN
RECESSING CUT (mm):• ceiling
65 x 330 x 110
b
h
PLEXI LED
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
176-275V
emergency exit signs
73
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COLOR
BASIC
PL 1W E 1 3 SE PT X GR WH
STANDARD
PL1W C 1 3 SA PT X GR WH
2W C 1 3 SA PT X GR WH
PREMIUM
1W B 1 3 SA AT RU GR WHPL
2W B 1 3 SA AT RU GR WH
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
PL1W F CB CBS X GR WH
2W F CB CBS X GR WH
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COLOR
1W Z CB ADE ADP GR WHPL
2W Z CB ADE ADP GR WH
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COLOR
PL1W FZLV GR WH
2W FZLV GR WH
LEGEND:
PL – fixture PLEXI LED
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
WH – white color
GR – grey color
emergency exit signs
74
ESCAPE LED
Steel body in white color
Plexi glass
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
I or III
IP RATING:
IP20
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
352
22
8
60
69
220-240VAC
50-60Hz
24VDC
d=30m
Ni-Cd
LED IP20176-275V
DC
LiFePO4
*see pictogramKM 61835 BS-EN
DIMENSIONS (mm):
MATERIALS:
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
emergency exit signs
75
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
BASIC
EL 1W E 1 3 SE PT X
STANDARD
EL1W C 1 3 SA PT X
2W C 1 3 SA PT X
PREMIUM
EL1W B 1 3 SA AT RU
2W B 1 3 SA AT RU
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
EL1W F CB CBS X
2W F CB CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
EL1W Z CB ADE ADP
2W Z CB ADE ADP
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM
EL1W FZLV
2W FZLV
LEGEND:
EL – fixture ESCAPE LED
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
emergency exit signs
76
HELIOS & HELIOS LED
White polycarbonate body
Transparent cover with Fresnel optics or opal polycarbonate cover
MOUNTING:
Surface (wall)
Optional assembly with wall or ceiling bracket
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
8W fluorescent lamp
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO4 6,4V batteries
INSULATION CLASS:
II or III
IP RATING:
IP42 or IP65
VIEWING DISTANCE:
25m
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
t : -25°C ÷ 40°C – together with heater for low temperaturesa
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Protection against mechanical impacts – IK08
III class of insulation of FZLV version
79356
13
6
24VDC
LED IP42
IP65
G5
T5
DIMENSIONS (mm):
*see pictogramKM 61835 BS-EN
176-275VDC
Ni-Cd LiFePO4
220-240VAC
50-60Hz
MATERIALS:
RW – RUBIC UNA Wireless central monitoring
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
emergency exit signs
77
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COVER
BASIC
HL HEL 1W E 1 3 SE PT X OP
STANDARD
HL HEL1W C 1 3 SA PT X OP
2W C 1 3 SA PT X OP
PREMIUM
HL HEL1W B 1 3 SA OP
2W B 1 3 SA OP
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COVER
1W F CB CBS X OPHL HEL
2W F CB CBS X OP
H HE 8W T CB CBS X TF
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COVER
1W Z CB ADE ADP OPHL HEL
2W Z CB ADE ADP OP
H HE 8W T CB ADL ADS TF
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COVER
1W FZLV OPHL HEL
2W FZLV
LEGEND:
HEL – fixture Helios led IP42
HL – fixture Helios led IP65
HE – fixture Helios IP42
H – fixture Helios IP65
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
T – electronic gear for LFL fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADL – central battery with ADL module
ADS – central battery with ADS address module – SMART technology
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
TF – transparent cover with Fresnel optics
OP – opal polycarbonate cover
AT RWRU
AT RWRU
OP
RW – RUBIC UNA Wireless central monitoring
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COVER
H HE 8W T 1 3 SE SA PT TFAT
emergency exit signs
78
HELIOS DS & HELIOS DS LED
White polycarbonate body
Opal polycarbonate cover
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
8W fluorescent lamp
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP42 or IP65
VIEWING DISTANCE:
25m
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
t : -25°C ÷ 40°C – together with heater for low temperaturesa
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Protection against mechanical impacts – IK08
III class of insulation of FZLV version
33
356
21
9
136
*see pictogram
24VDC
d=25m
Ni-Cd
LED IP42
IP65
G5T5
DIMENSIONS (mm):
DC
LiFePO4
KM 61835 BS-EN
220-240VAC
50-60Hz
MATERIALS:
RW – RUBIC UNA Wireless central monitoring
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
176-275V
emergency exit signs
79
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
BASIC
HDL HDEL 1W E 1 3 SE PT X
STANDARD
HDL HDEL1W C 1 3 SA PT X
2W C 1 3 SA PT X
HD HDE 8W T 1 3 SE SA PT
PREMIUM
HDL HDEL1W B 1 3 SA
2W B 1 3 SA
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
1W F CB CBS XHDL HDEL
2W F CB CBS X
HD HDE 8W T CB CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
1W Z CB ADE ADPHDL HDEL
2W Z CB ADE ADP
HD HDEL 8W T CB ADL ADS
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM
1W FZLVHDL HDEL
2W
LEGEND:
HDEL – fixture Helios DS led IP42
HDL – fixture Helios DS led IP65
HDE – fixture Helios DS IP42
HD – fixture Helios DS IP65
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
T – electronic gear for LFL fittings;
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADL – central battery with ADL module
ADS – central battery with ADS address module – SMART technology
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
AT RWRU
AT RWRU
RW – RUBIC UNA Wireless central monitoring
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
PT
FZLV
emergency exit signs
80
TIGER & TIGER LED
White polycarbonate body
Transparent or opal polycarbonate cover
MOUNTING:
Surface (wall)
Optionally recessed (wall**)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
8W fluorescent lamp
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO4 6,4V batteries
INSULATION CLASS:
II or III
IP RATING:
IP22
VIEWING DISTANCE:
20m
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
**requires an accessory for recessed mounting
11
8
350
323
14
4
*see pictogram
24VDC
Ni-Cd
LED G5
T5 IP22
DIMENSIONS (mm):
DC
d=20m
LiFePO4
KM 61835 BS-EN
220-240VAC
50-60Hz
MATERIALS:
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
176-275V
325 x 120
RECESSING CUT (mm):
• wall
emergency exit signs
81
SELF-CONTAINED CONFIGURATION:
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COVER
BASIC
TL 1W E 1 3 SE PT X OP
STANDARD
TL1W C 1 3 SA PT X OP
2W C 1 3 SA PT X OP
TG 8W T 1 3 SE SA PT TR
PREMIUM
TL1W B 1 3 SA AT RU OP
2W B 1 3 SA AT RU OP
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COVER
TL1W F CB CBS X OP
2W F CB CBS X OP
TG 8W T CB CBS X TR
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS COVER
1W Z CB ADE ADP OPTL
2W Z CB ADE ADP OP
TG 8W T CB ADL ADS TR
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM COVER
TL1W FZLV OP
2W FZLV
LEGEND:
TG – fixture Tiger
TL – fixture Tiger LED
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
T – electronic gear for LFL fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring system
CB – central battery version
CBS – central battery for circuit monitoring
ADL – central battery with ADL module
ADS – central battery with ADS address module – SMART technology
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
TR – transparent polycarbonate cover
OP – opal polycarbonate cover
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS COVER
AT
OP
emergency exit signs
82
TIGER DS & TIGER DS LED
White polycarbonate body
Opal polycarbonate cover
MOUNTING:
Surface (ceiling)
Optionally recessed (ceiling**)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W LED
8W fluorescent lamp
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II or III
IP RATING:
IP22
VIEWING DISTANCE:
20m
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
**requires an accessory for recessed mounting
323
18
6
118
350 144
*see pictogram
DIMENSIONS (mm):
KM 61835 BS-EN
24VDC
d=20m
Ni-Cd
LED G5
T5 IP22
176-275VDC
LiFePO4
220-240VAC
50-60Hz
MATERIALS:
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
325 x 120
RECESSING CUT (mm):
• wall
emergency exit signs
83
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
BASIC
TSL 1W E 1 3 SE PT X
STANDARD
1W C 1 3 SA PT XTSL
2W C 1 3 SA PT X
TGS 8W T 1 3 SE SA PT
PREMIUM
1W B 1 3 SA AT RUTSL
2W B 1 3 SA AT RU
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
TSL1W F CB CBS X
2W F CB CBS X
TGS 8W T CB CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
TSL1W Z CB ADE ADP
2W Z CB ADE ADP
TGS 8W T CB ADL ADS
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM
1W FZLVTSL
2W
LEGEND:
TGS – fixture Tiger DS
TSL – fixture Tiger DS LED
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
T – electronic gear for LFL fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring system
CB – central battery version
CBS – central battery for circuit monitoring
ADL – central battery with ADL module
ADS – central battery with ADS address module – SMART technology
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
AT
FZLV
emergency exit signs
84
MATERIALS:
Aluminium body
Plexi glass
MOUNTING:
Surface (wall)
POWER SUPPLY:
self contained – 220÷240VAC/50÷60Hz
central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC
central battery FZLV – 24VDC
LIGHT SOURCE:
SC30 3x1W; SC40 3W; SC60 2x3W LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
I or III
IP RATING:
IP40
VIEWING DISTANCE:
30, 40 or 60m (depends on version)
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
OPTIONS:
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
III class of insulation of FZLV version
220-240VAC
50-60Hz
24VDC
LED IP40
d=30m
b
a c d
*see pictogram
Ni-Cd
176-275VDC
LiFePO4
d=60md=40m
KM 61835 BS-EN
DIMENSIONS (mm):
Dimensions [mm]
TYPE a[mm] b[mm] c[mm] d[mm]
SC30 315 165 50 8
SC40 415 215 50 8
SC60 615 315 50 8
SCREEN
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
emergency exit signs
85
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
STANDARD
SC30 3x1W C 1 3 SA PT X
SC40 3W C 1 3 SA PT X
SC60 2x3W C 1 3 SA PT X
PREMIUM
SC30 3x1W B 1 3 SA AT RU
SC40 3W B 1 3 SA AT RU
SC60 2x3W B 1 3 SA AT RU
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
SC30 3x1W F CB CBS X
SC40 3W F CB CBS X
SC60 2x3W F CB CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
SC30 3x1W Z CB ADE ADP
SC40 3W Z CB ADE ADP
SC60 2x3W Z CB ADE ADP
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM
SC30 3x1W FZLV
SC40 3W FZLV
SC60 2x3W
LEGEND:
SC30 – fixture Screen viewing distance 30m
SC40 – fixture Screen viewing distance 40m
SC60 – fixture Screen viewing distance 60m
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring system
CB – central battery version
CBS – central battery for circuit monitoring
ADP – central battery with ADP address module – SMART technology
ADE – central battery with ADE address module
FZLV – central battery FZLV 24 VDC
FZLV
emergency exit signs
86
Dimensions [mm]
TYPE a[mm] b[mm] c[mm]
SCS30 315 165 50
SCS40 415 215 50
SCS60 615 315 50
MATERIALS:
Aluminium body
Plexi glass
MOUNTING:
Surface (ceiling)
Optionally mounting on a rope sling (ceiling**)
POWER SUPPLY:
self contained – 220÷240VAC/50÷60Hz
central battery – 220÷240VAC/50÷60Hz; 176 - 275VDC
central battery FZLV – 24VDC
LIGHT SOURCE:
SCS30 3x1W; SCS40 3W; SCS60 2x3W LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
I or III
IP RATING:
IP40
VIEWING DISTANCE:
30, 40 or 60m (depends on version)
AMBIENT TEMPERATURE:
t : 0°C ÷ 40°Ca
OPTIONS:
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
III class of insulation of FZLV version
**requires an accessory for mounting on a rope sling
b
a c
DIMENSIONS (mm):
*see pictogramKM 61835 BS-EN
SCREEN DS
*1pc of universal pictogram is included in each single box
Current list of products with Kitemark and ENEC is available at www.awex.eu
220-240VAC
50-60Hz
24VDC
LED IP40
d=30m
Ni-Cd
176-275VDC
LiFePO4
d=60md=40m
emergency exit signs
87
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
STANDARD
SCS30 3x1W C 1 3 SA PT X
SCS40 3W C 1 3 SA PT X
SCS60 2x3W C 1 3 SA PT X
PREMIUM
SCS30 3x1W B 1 3 SA AT RU
SCS40 3W B 1 3 SA AT RU
SCS60 2x3W B 1 3 SA AT RU
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
SCS30 3x1W F CB CBS X
SCS40 3W F CB CBS X
SCS60 2x3W F CB CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
SCS30 3x1W Z CB ADE ADP
SCS40 3W Z CB ADE ADP
SCS60 2x3W Z CB ADE ADP
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM
SCS30 3x1W FZLV
SCS40 3W FZLV
SCS60 2x3W FZLV
LEGEND:
SCS30 – fixture Screen DS viewing distance 30m
SCS40 – fixture Screen DS viewing distance 40m
SCS60 – fixture Screen DS viewing distance 60m
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring system
CB – central battery version
CBS – central battery for circuit monitoring
ADP – central battery with ADP address module – SMART technology
ADE – central battery with ADE address module
FZLV – central battery FZLV 24 VDC
emergency exit signs
88
MATERIALS:
Opal plexi glass body
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3x1W LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
I or III
IP RATING:
IP41
VIEWING DISTANCE:
25m
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
240
24
0
*see pictogram
LED
DIMENSIONS (mm):
DC
220-240VAC
50-60Hz
QUADRO
Ni-Cd
d=25m
LiFePO4
176-275V 24VDC
emergency exit signs
89
Legend:
Q – fixture Quadro
C – electronic gear for STANDARD self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring system
CB – central battery version
CBS – central battery for circuit monitoring
ADL – central battery with ADL module
ADS – central battery with ADS address module – SMART technology
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
STANDARD
Q 3x1W C 1 3 SA PT X
PREMIUM
Q 3x1W B 1 3 SA AT RU
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
Q 3x1W F CB CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
Q 3x1W Z CB ADE ADP
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM
Q 3x1W FZLV
Special application luminaires
ESCAPELITE FLAGLIGHTESCAPELITE LIKLED WALL LINE
IKLED 92ESCAPELITE 94ESCAPELITE L 95FLAGLIGHT 96WALL LINE 97
Special application luminaires
92
220-240VAC
50-60Hz
176-275VDC
LED
IP65
Tempered glass or plexi glass
MATERIALS:
Stainless steel or painted steel body
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
LIGHT SOURCE:
3W or 6W LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
I or III
IP&KPA RATING:
IP65, 10KPA
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
OPTIONS:
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
IKLED
IK10d=30m
DIMENSIONS (mm):
23
8
408 61
Optionally recessed* (wall, ceiling)
Central battery FZLV – 24VDC
t : -25°C ÷ 40°C – together with heater for low temperaturesa
Optional adaptation of the fixture for low temperatures up to -25°C
III class of insulation of FZLV version
*see pictogram
*Pictograms for tunnel luminaires have to be ordered separately and according to the local requirements.
LiFePO4
24VDC
Special application luminaires
93
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
IK3W B 1 3 SA AT RU
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
3W F CB CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
ESC 3W Z CB ADP
Legend:
IK – fitting IKLED with steel painted body and plexi glass
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SA – maintained (with an option of connecting as non-maintained)
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADP – central battery with ADP address module – SMART technology
FZLV SYSTEM CONFIGURATION
CODE POWER SYSTEM
3W FZLV
WH GR BL
COLOR
IKP3W B 1 3 SA AT RU ST
IKP – fitting IKLED with steel stainless body and tempered glass
6W B 1 3 SA AT RU WH GR BL
6W B 1 3 SA AT RU ST
IK6W F CB CBS X
IKP3W F CB CBS X
6W F CB CBS X
IK6W Z CB ADP
ESC 3W Z CB ADPIKP
6W Z CB ADP
WH GR BL
COLOR
ST
WH GR BL
ST
WH GR BL
COLOR
ST
WH GR BL
ST
IKP 3W FZLV
IK WH GR BL
ST
COLOR
WH – white color
GR – grey color
BL – black color
ST – stainless steel
*Pictograms for tunnel luminaires have to be ordered separately and according to the local requirements.
Special application luminaires
94
220-240VAC
50-60Hz
176-275VDC
IK10
LED IP65
DIMENSIONS (mm):
Ni-Cd
d=40m
31
2
491 223
Tempered glass (5mm)
MATERIALS:
Stainless steel body
MOUNTING:
Surface (wall)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
LIGHT SOURCE:
3x1W LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1, 3h, high temperature Ni-CD batteries
INSULATION CLASS:
I
IP&KPA RATING:
IP65, 10KPA
VIEWING DISTANCE:
40m
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
OPTIONS:
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
ESCAPELITE
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
ESC 3W B 1 3 SA PT AT RU
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
ESC 3W F CB CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
ESC 3W Z CB ADP
Legend:
ESC – fitting ESCAPELITE
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADP – central battery with ADP address module – SMART technology
*see pictogramKM 61835 BS-EN
*Pictograms for tunnel luminaires have to be ordered separately and according to the local requirements.
Special application luminaires
95
220-240VAC
50-60Hz
176-275VDC
IK10
LED IP65
DIMENSIONS (mm):
Ni-Cd
d=30m
Tempered glass (5mm)
MATERIALS:
Stainless steel body
MOUNTING:
Surface (wall)
POWER SUPPLY:
Self contained – 220 - 240VAC/50 - 60Hz
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
LIGHT SOURCE:
3x1W LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1, 3h, high temperature Ni-CD batteries
INSULATION CLASS:
I
IP&KPA RATING:
IP65, 10KPA
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
OPTIONS:
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
ESCAPELITE L
SELF-CONTAINED CONFIGURATION
CODE POWER MODULE AUTONOMY [h] MODE OPTIONS
ESL 3W B 1 3 SA PT AT RU
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
ESL 3W F CB CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
ESL 3W Z CB ADP
Legend:
ESL – fitting ESCAPELITE L
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADP – central battery with ADP address module – SMART technology
22
2
506 366
*see pictogram
*Pictograms for tunnel luminaires have to be ordered separately and according to the local requirements.
Special application luminaires
96
220-240VAC
50-60Hz
176-275VDC
IK10
LED IP65
DIMENSIONS (mm):
d=60m
Plexi glass
MATERIALS:
Stainless steel body
MOUNTING:
Surface (wall)
POWER SUPPLY:
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
LIGHT SOURCE:
20x1W LED
INSULATION CLASS:
I
IP&KPA RATING:
IP65, 10KPA
VIEWING DISTANCE:
60m
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
OPTIONS:
CB – central battery
FLAGLIGHT
CENTRAL BATTERY CONFIGURATION – NON-ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
FLA 20x1W F CB CBS X
CENTRAL BATTERY CONFIGURATION – ADDRESSABLE
CODE POWER MODULE SYSTEM OPTIONS
FLA 20x1W Z CB ADS
Legend:
FLA – fitting FLAGLIGHT
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
CBS – central battery for circuit monitoring
ADS – central battery with ADS address module – SMART technology
39
6
478 150
*Pictograms for tunnel luminaires have to be ordered separately and according to the local requirements.
Special application luminaires
97
Plexi glass
MATERIALS:
Stainless steel body
MOUNTING:
Surface (wall)
POWER SUPPLY:
Central battery – 220 - 240VAC/50 - 60Hz; 176 - 275VDC
LIGHT SOURCE:
max. 2W – high intensity led
INSULATION CLASS:
I
IP RATING:
IP65
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
OPTIONS:
DES – dynamic escape system
WALL LINE
CONFIGURATION
CODE POWER SYSTEM OPTIONS
WLL 2W CB DES
Legend:
WLL – fixture WALL LINE
CB – central battery
DES – dynamic escape system
ADDITIONAL INFORMATION:
Luminaire cooperates only with the dynamic escape sign system DES
Luminaire indicate red or green light according to scenerios from DES.
Possibility to connect several segments together
DIMENSIONS (mm):
11
2
820 140
220-240VAC
50-60Hz
176-275VDC
DES
LED IP65
*Pictograms for tunnel luminaires have to be ordered separately and according to the local requirements.
emergency conversion kits
100UNILED GU10 101UNILED BM 102UNILED UM 104EML 106
NEXT & NEXT AUTOTEST
UNILED BMUNILED GU10 UNILED UM
NEXT & NEXT AUTOTEST
EML
emergency conversion kits
100
NEXT & NEXT AUTOTEST
MATERIALS:
Polycarbonate body
MOUNTING:
Inside the fixture
POWER SUPPLY:
230 VAC/50-60 Hz
LIGHT SOURCE:
Linear and compact fluorescent lamps
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h or 3h; Ni-Cd battery
INSULATION CLASS:
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
t : 0°C÷55°Ca
t : -25°C ÷ 55°C – together with heater for low temperaturesa
OPTIONS:
PT – manual test button
AT – autotest
ADDITIONAL INFORMATION:
A new generation of conversion kits which replaces conversion kits series LIDER
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Cooperation with magnetic and electronic ballasts
Optional adaptation of conversion kit for low temperatures up to -25°C
230VAC
50-60HzIP20
Ni-Cd
157
35
42
NEXT – ORDER CODES
CODE POWER [W] AUTONOMY [h] OPTION BATTERY
NX/36/1 6 – 36 1 PT Ni-Cd 3,6V 1,5Ah
NX/36/3 6 – 36 3 PT Ni-Cd 3,6V 4,0Ah
NX/58/1 6 – 58 1 PT Ni-Cd 4,8V 1,5Ah
NX/58/3 6 – 58 3 PT Ni-Cd 4,8V 4,0Ah
NX/80/1 6 – 80 1 PT Ni-Cd 6,0V 1,5Ah
NX/80/3 6 – 80 3 PT Ni-Cd 6,0V 4,0Ah
NEXT AUTOTEST – ORDER CODES
CODE POWER [W] AUTONOMY [h] BATTERY
NX/36/1/AT 6 – 36 1 Ni-Cd 3,6V 2,0Ah
NX/36/3/AT 6 – 36 3 Ni-Cd 3,6V 4,5Ah
NX/58/1/AT 6 – 58 1 Ni-Cd 4,8V 2,0Ah
NX/58/3/AT 6 – 58 3 Ni-Cd 4,8V 4,5Ah
NX/80/1/AT 6 – 80 1 Ni-Cd 6,0V 2,0Ah
NX/80/3/AT 6 – 80 3
Test types (version AT):
Test A is run automatically every 28 days
During test A a conversion kit is switched to emergency mode
for 1 minute and the following parameters are checked:
• control of battery power discharge
• control of battery voltage
Test B is run automatically every 364 days
During test B a conversion kit is switched to emergency
mode for all duration time (1, 2, 3 hours) and the following
parameters are checked:
• control of battery power discharge
• control of minimum battery voltage
LED INDICATOR
LED color Signal Symbolizing
no signal emergency mode / running test
shining defective battery
flashing defective lamp
no signal emergency mode / running test
shining normal mode
flashing normal mode, battery charging
Current list of products with Kitemark and ENEC is available at www.awex.eu
KM 618354BS-EN 61347-2-7
Ni-Cd 6,0V 4,5Ah
DIMENSIONS (mm):
emergency conversion kits
101
MATERIALS:
Polycarbonate body
MOUNTING:
Inside the fixture
POWER SUPPLY:
230VAC/50-60Hz
LIGHT SOURCE:
3,5–8W LED
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h or 3h; Ni-Cd battery
INSULATION CLASS:
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
OPTIONS:
PT – manual test button
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge Deep
discharge protection
Designed for cooperation with LED light sources with voltage 180VDC
In emergency mode light stream is 80% of the nominal stream
Uniled GU10 – ORDER CODE
CODE POWER [W] AUTONOMY [h] OPTION BATTERY
GU10/1 3,5 – 8 1 PT Ni-CD 7,2V 1,5Ah
GU10/3 3,5 – 8 3 PT Ni-CD 7,2V 4,0Ah
230VAC
50-60HzIP20
Ni-Cd
157
35
42
UNILED GU10
emergency conversion kits
102
UNILED BM
Polycarbonate body
MOUNTING:
Inside the fixture
POWER SUPPLY:
220÷240 VAC/50-60 Hz
LIGHT SOURCE:
1W, 2W, 3W, 6W*, LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 4,8V batteries
PREMIUM: 1h or 3h, LiFePO 6,4V batteries4
INSULATION CLASS:
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
t : 0°C÷40°Ca
t : -25°C ÷ 55°C – together with heater for low temperaturesa
OPTIONS:
PT – manual test button
AT – autotest
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of conversion kit for low temperatures up to -25°C
Automatic detection of battery capacity and setting test parameters
Output voltage: 3.3 VDC
Output curent: BM 1W – 350mA, BM 3W 1000mA, BM 6W – 2000mA
* 6W – power of light source only in non-maintained fixtures
220-240VAC
50-60HzIP20
Ni-Cd
Test types (version AT):
Test A is run automatically every 28 days
During test A a conversion kit is switched to emergency mode
for 1 minute and the following parameters are checked:
• control of battery power discharge
• control of battery voltage
Test B is run automatically every 364 days
During test B a conversion kit is switched to emergency
mode for all duration time (1, 2, 3 hours) and the following
parameters are checked:
• control of battery power discharge
• control of minimum battery voltage
134
22
38
LED INDICATOR - UNILED BM PREMIUM
LED color Signal Symbolizing
no signal emergency mode / running test
shining defective battery
flashing defective lamp
no signal emergency mode / running test
shining normal mode
flashing battery is being loaded, normal mode
LED INDICATOR - UNILED BM STANDARD
LED color Signal Symbolizing
no signal emergency mode / Standby mode
shining Standby mode (battery is full)
flashing battery is being loaded, normal mode
LiFePO4
Current list of products with Kitemark and ENEC is available at www.awex.eu
KM 618354BS-EN 61347-2-7
MATERIALS:
DIMENSIONS (mm):
emergency conversion kits
103
UNILED BM STANDARD – ORDER CODES
CODE POWER [W] AUTONOMY [h] OPTION BATTERY
BM/1/1/PT/CD
1
1 PT Ni-CD 4,8V 1,0Ah
BM/1/3/PT/CD 3 PT Ni-CD 4,8V 1,5Ah
BM/1/8/PT/CD 8 PT Ni-CD 4,8V 4,0Ah
BM/2/1/PT/CD2
1 PT Ni-CD 4,8V 1,0Ah
BM/2/3/PT/CD 3 PT Ni-CD 4,8V 2,5Ah
BM/3/1/PT/CD3
1 PT Ni-CD 4,8V 1,5Ah
BM/3/3/PT/CD 3 PT Ni-CD 4,8V 4,0Ah
BM/6/1/PT/CD6
1 PT Ni-CD 4,8V 4,0Ah
BM/6/3/PT/CD 3 PT Ni-CD 4,8V 8,0Ah
CODE POWER [W] AUTONOMY [h] OPTION BATTERY
BM/1/1/AT/Li
1
1 AT LiFePO 6,4V 1,0Ah4
BM/1/3/AT/Li 3 AT LiFePO 6,4V 1,0Ah4
BM/1/8/AT/Li 8 AT LiFePO 6,4V 3,0Ah4
BM/2/1/AT/Li2
1 AT LiFePO 6,4V 1,0Ah4
BM/2/3/AT/Li 3 AT LiFePO 6,4V 2,0Ah4
BM/3/1/AT/Li3
1 AT LiFePO 6,4V 1,5Ah4
BM/3/3/AT/Li 3 AT LiFePO 6,4V 3,0Ah4
BM/6/1/AT/Li6
1 AT LiFePO 6,4V 3,0Ah4
BM/6/3/AT/Li 3 AT LiFePO 6,4V 6,0Ah4
UNILED BM PREMIUM – ORDER CODES
emergency conversion kits
104
UNILED UM
Polycarbonate body
MOUNTING:
In the fixture
Optional in additional housing*
POWER SUPPLY:
220÷240VAC/50÷60Hz
LIGHT SOURCE:
Power mode: max 80W
Designed for cooperation with LED light sources with voltage 12V - 90VDC - max 80W
OUTPUT POWER:
BASIC: 3W
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 7,2V batteries
STANDARD: 1h, 3h or 8h Ni-Cd 7,2V batteries
PREMIUM: 1h, 3h or 8h, LiFePO 9,6V batteries4
INSULATION CLASS:
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
t : 0°C÷50°Ca
OPTIONS:
PT – manual test button
AT – autotest
ADDITIONAL INFORMATION:
Deep discharge protection
Optional adaptation of conversion kit for low temperatures up to -25°C
Automatic detection of battery capacity and setting test parameters
Automatic detection of LED light source voltage in Power mode
In emergency mode the incorrect settings are detected by LED indicator
Autonomy 1h, 3h, 8h set by jumper
**requires an accessory for Uniled UM housing
220-240VAC
50-60HzIP20
Ni-Cd
157
35
42
Type of batteryAUTONOMY [h]
1h 3h 8h
7,2V 1000mAh 3W 1W –
7,2V 1500 mAh 4W 2W 1W
7,2V 2500mAh 8W 3W 1W
7,2V 4000mAh 9W 5W 2W
7,2V 8000mAh 9W 9W 4W
9,6V 1500mAh 6W 3W 1W
9,6V 3000mAh 9W 5W 2W
9,6V 6000mAh 9W 9W 4W
Ni-
Cd
LiF
eP
O4
POWER MODE
SETTINGS
Light output in emergency mode (only power mode)
light output in emergency mode
light output in mains mode
LED power in emergency mode
LED power in mains mode=
light output in emergency mode [lm]LED power in emergency mode [W]
LED power in mains mode [W]= x light output in mains mode [lm]
Power mode, choice of output power
in the range: 1W - 9W
OFF
UNILED UMLED
power supplymax. 80W
LiFePO4
Current list of products with Kitemark and ENEC is available at www.awex.eu
KM 618354BS-EN 61347-2-7
MATERIALS:
DIMENSIONS (mm):
STANDARD, PREMIUM: 1 - 9W
emergency conversion kits
105
Test types (version AT):
Test A is run automatically every 28 days
During test A a conversion kit is switched to emergency mode
for 1 minute and the following parameters are checked:
• control of battery power discharge
• control of battery voltage
Test B is run automatically every 364 days
During test B a conversion kit is switched to emergency
mode for all duration time (1, 2, 3 hours) and the following
parameters are checked:
• control of battery power discharge
• control of minimum battery voltage
CONFIGURATION OF BATTERY PACKAGES
UNILED UM STANDARD – ORDER CODES
CODEBATTERY
OPTIONCAPACITY TYPE PACKAGES
10 CD B1 B2 B3 PT
15 CD B1 B2 B3 PT
UM 25 CD B1 B2 B3 PT
40 CD B1 B2 B3 PT
80 CD B1 B2 B3 PT
CODEBATTERY
OPTIONCAPACITY TYPE PACKAGES
15 Li B1 B2 B13 AT
UM 30 Li B1 B2 B13 AT
60 Li AT
UNILED UM BASIC – ORDER CODES
CODEBATTERY
CAPACITY TYPE PACKAGES
UMB10 CD B1
25 CD
Legend:
PT – manual test button
AT – autotest
UM – conversion kit Uniled UM
10 – battery capacity 1000 mAh
15 – battery capacity 1500 mAh
25 – battery capacity 2500 mAh
30 – battery capacity 3000 mAh
40 – battery capacity 4000 mAh
60 – battery capacity 6000 mAh
80 – battery capacity 8000 mAh
CD – battery type Ni-Cd
Li – battery type LiFePO4
B1 – battery Stick
B2 – battery Akku Pack
B3 – battery Akku Pack block
B13 – battery Akku Pack block
B4 – battery Akku Pack block
LED indicator – uniled UM Basic/Standard
LED color Signal Symbolizing
no signal emergency mode / Standby mode
shining Standby mode (battery is full)
flashing battery is being loaded, normal mode
LED indicator – uniled UM Premium
LED color Signal Symbolizing
no signal emergency mode / running test
shining defective battery
flashingdefective lamp, too much output power for this battery capacity
no signal emergency mode / running test
shining normal mode
flashing battery is being loaded, normal mode
B13
B4
B1 B2 B4
B1
UNILED UM PREMIUM – ORDER CODES
UMB – conversion kit Uniled UM BASIC
emergency conversion kits
106
EML
POWER LED or LED SMD
NUMBER OF LED DIODES:
1x power LED or 8x LED SMD or 20x LED SMD
LIGHT SOURCE:
3W
Self contained – 220÷240VAC/50÷60Hz
CHARGING:
INSULATION CLASS:
II
AMBIENT TEMPERATURE:
t : 0°C ÷ 55°C a
OPTIONS:
SE – non maintained
AT – autotest
COLOR TEMPERATURE
6000 - 6500 K
CRI:
R >85a
LUMINOUS EFFICIENCY
100 - 180 lm/W
VIEWING ANGLE:
125°
LIFETIME:
50000h
DIMENSION:
POWER LED: 45x45x4 mm
LED SMD: 177x10x2,5 mm
Conversion kit: 130x38x22 mm
Batteries: *see table below
LED TYPE :
DIMENSIONS (mm):
POWER SUPPLY:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
2.9-3.2V125° 50000h
6000-6500 K
LED
220-240VAC
50-60Hz
LiFePO4
NiCD
POWER LED
CONVERSION KIT
LED SMD
BATTERY
45
45
A
B
C
134
22
38
10
178
2,5
emergency conversion kits
107
SELF - CONTAINED CONFIGURATION
CODE POWER AUTONOMY [h] OPTIONS
BM 3W 1 3 AT
BMA 3W 1 3 PT
STANDARD
PREMIUM
BATTERY
1h 3h
3,6V 1,5Ah 3,6V 4,0Ah
6,4V 1,5Ah 6,4V 3,0Ah
CODECAPACITY
[mAh]
DIMENSION [MM]
A x B x C
1500 135x20,5x19
3000 140x28,5x27Li
1500 175x27x25
4000 240x37x35CD
BATTERY CONFIGURATION
CODE POWER LUMEN OUTPUT
3W 126 - 165 lm/WLS01
3W 100 - 140 lm/WLS02
LIGHT SOURCE CONFIGURATION
LS01 - light source power LED
PT – manual test button
AT – autotest
Legend:
Li - battery LiFePO4
CD - battery NiCD
BMA - conversion kit UNILED BMA
BM - conversion kit UNILED BM
LS02 - light source LED SMD
MOUNTING HOLES (mm):
34,5
34,5
19
123,5
28,7
120
3W 140 - 180 lm/WLS03
LS03 - light source high efficiency LED SMD
LS01
LS02 / LS03
BMA / BM
systems
CENTRAL BATTERY SYSTEM CBS
SMART VISIO PLATFORM
RUBIC MINI UNA 110RUBIC UNA 111
CENTRAL BATTERY SYSTEM FZLV 118
CENTRAL BATTERY SYSTEM LPS 122CENTRAL BATTERY SYSTEM CBS 124THE SMART VISIO PLATFORM
RUBIC UNA WIRELESS 112DYNAMIC ESCAPE SYSTEM DES 114FIRE ALARM SYSTEM FAS 116
CENTRAL BATTERY SYSTEM SPS 120
126
RUBIC UNA CENTRAL BATTERY SYSTEM FZLV
CENTRAL BATTERY SYSTEM LPS
RUBIC MINI UNA RUBIC UNAWIRELESS
FIRE ALARMSYSTEM FAS
DYNAMIC ESCAPE SYSTEM DES
systems
110
RUBIC MINI UNA
The RUBIC MINI UNA system is a modern, compact solution designed
for the monitoring of emergency luminaires with unique addresses
installed in small-size buildings and facilities. The system offers the
possibility to supervise up to 500 emergency luminaires equipped with RU-
type power supply sources.
The main advantages of the MINI UNA control unit are its compact
size and the possibility to mount it on a DIN-3 standard rail (TH35). The
system is simplified but not deprived of the most important functionalities
from the user’s point of view. Each control unit is equipped with an RS485
connection for the communication bus, an RJ45 connector, four LEDs
indicating the current status of the system, three function keys which can
be programmed in the control unit, a reset button and a service pin to
assign a unique IP address to the unit. Additionally, the control unit has
two potential-free input contacts and two voltage outputs (so-called ‘open
collector’). Communication with RU emergency luminaires is provided by
means of an RS485 standard communication bus. A single bus may not
exceed 1200 m when linear topology is used. The communication with
luminaires is continuous.
Key features:
• Monitoring of up to 500 emergency luminaires
• Maximum length of a single bus is 1200 m
• System status LEDs
• TH35 (DIN-3) rail mounted
• Three programmable function keys
• Two potential-free inputs (current loops)
• Two voltage outputs (to control external relays)
• Internal memory to store emergency lighting system reports, compliant
with PN-EN 50172
• Mains supply mode, configured from the control unit
• Testing of individual luminaires or groups of luminaires
• Built-in battery to provide back-up power supply to the control unit
• RJ45 connector for direct communication with any computer via
Ethernet
• Individually programmable IP address
• System status preview using any web browser
• Continuous communication with luminaires installed in the system
• System management and visualization by means of dedicated SMART
VISIO software
01.001 01.002 01.003 01.099 01.10000–0A–139A–F001 00–0B–C21A–0020 00–01–1A1F–F001 00–00–1C2C–F001 00–01–1A0D–F0FF
02.001 02.033 02.123 02.24000–0A–132A–F091 00–0A–141A–9000 00–00–122C–F901 00–00–122C–F001
LANmax. 100m
LANmax. 100m
ROUTERROUTER
INTERNETINTERNET WWWWWW
RS485max. 1200m
RS485max. 1200m
RUBIC MINI UNA
PCPC
PC
max.
PC
500units
systems
111
RUBIC UNA
The RUBIC UNA is the latest and the most advanced monitoring
system designed to control independent luminaires of emergency and
escape route lighting systems. It is designed to be used in medium-to-large
facilities and buildings. Each control unit can handle up to 4000 luminaires
using MPU250 Power submodules. The submodules communicate
with the RUBIC UNA control unit via LAN. The use of LAN also enables
communication between individual submodules.
The RUBIC UNA system is equipped with a touch panel and an intuitive
graphic menu to enable quick and easy system configuration without the
need for using SMART VISIO.
Thanks to introduced technical solutions polarity does not need to be
observed any more while connecting a communication bus to the following
system components:
• RUBIC UNA control unit
• MPU250 Power submodules
• RU address modules
Each RU address module is assigned an individual number/address. The
addresses are factory-assigned, so an addressing unit is not required for
installation, setting up or maintenance work.
Key features:
• Touch screen control unit
• Unique addresses of luminaires
• Factory-assigned module addresses
• No need for an addressing unit
• Intuitive GUI
• No need to observe the polarity of communication cables
• Four built-in potential-free contacts (input and output)
• Remote control option via Ethernet and a dedicated website
• Monitoring of up to 750 luminaires per control unit (3 logical buses: 01,
02 and 03 – each one with 2 physical channels)
• Possibility to expand the control system to 4000 luminaires using
submodules
• System status indication by means of icons on the control unit screen
• Compatibility with fluorescent and LED light sources
• Internal battery enabling continuous operation of the control unit
• Automatic performance of tests
• Registration of test results in an event log
• Division of luminaires into groups with freely adjustable testing times
• Mains supply mode for selected luminaires/groups
• System management and visualization by means of dedicated SMART
VISIO software
• BACnet standard, enabling compatibility of the RUBIC UNA with Building
Management Systems (BMS) SMART VISIO
MPU250 - POWER
MPU250 - POWER
RS485max. 1200m
RS485max. 1200m
RS485max. 1200m
LANmax. 100m RUBIC UNA
LANmax. 100m
ROUTER
INTERNET
WWWPC
06.001 06.002 06.003 06.09100–0A–2A3A–F001 00–1A–1F1A–0001 00–00–1F1D–F001 00–10–1F2C–F021
05.001 05.002 05.007 05.21100–0A–214C–F001 00–1A–141C–0120 00–00–113F–C201 00–10–12CC–F321
04.001 04.043 04.123 04.24000–2A–231A–F022 00–1A–131A–0143 00–00–311D–F029 00–10–322C–F028
RS485max. 1200m
03.001 03.003 03.03100–1A–145A–0143 00–00–115D–F029 00–10–126C–F027
RS485max. 1200m
02.001 02.033 02.12300–1A–144A–0143 00–00–141D–F029 00–10–142C–F023
RS485max. 1200m
01.001 01.010 01.12300–1A–121A–0143 00–00–121D–F029 00–10–132C–F023
Max250
units
Max250
units
Max750
units
Max4000units
systems
112
RUBIC UNA WIRELESS
Key features:
• Central unit with a touch panel
• Unique luminaire addresses
• Modules addressed during manufacturing
• Address programmer not required
• Intuitive graphic menu
• Communication in band ISM 868MHz
• Range up to 200m in open space
• Possible to use signal booster
• 4 potential-free inputs and outputs built in the central unit
• Possible to have remote control via Ethernet and website
• The central unit monitors up to 250 wireless luminaires
• Possible to extend to have 4000 luminaires thanks to the use of
subordinate modules
• Possible to connect Wireless luminaires and cable luminaires
• System status signaling via icons on the central unit screen
• Possible to connect LED sources of light
• Internal storage battery for continuous operation of the central unit
• Automatic tests
• Recording test results in event log
• Possible to divide luminaires into groups with any testing time
• Network operation mode for selected luminaires/groups
• System management and presentation by means of dedicated
SmartVISIO software
• BACnet system assuring compatibility of RUBIC UNA RW
RUBIC UNA Wireless system is the latest and most advanced version of the monitoring system intended for emergency and evacuation luminaires. It is
dedicated to medium-sized and large facilities. Each central unit can control up to 4000 luminaires with the use of subordinate modules MPW250 – Power.
Subordinate modules communicate with RUBIC UNA RW central unit via LAN network. Communication between luminaires and central unit is wireless. The use
of Mesh network and innovative data sending algorithms has allowed to have a range of 200m in the open space. The system operates in the band ISM 868
MHz which allows overcoming such obstacles as a concrete ceiling and walls. Thanks to the band, it is possible to increase the range fourfold when compared
to devices operating in the band 2,4GHz, e.g. Wi-Fi standard access points.
MPW250 POWER
MPU250 POWER
LANmax. 100m
LANmax. 100m
RUBIC UNA WIRELESSROUTER
INTERNET WWWPC
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
RS485max. 1200m
with BMS system
systems
113 73
SYSTEM ELEMENTS
MODULE MPW250 – POWER
Key features:
• Assembly of subordinate module on bus DIN-3 (TH35)
• Monitoring up to 250 luminaires
• Connection to Ethernet – communication via LAN
• "Service pin" key and Reset
• Possible to set IP address on one's own
• Built-in wireless feeder
• Built-in storage battery charging LED
ADDRESS MODULE WIRELESS
Key features:
• Cooperation with LED source of light
• Emergency mode switch
• Compatible with storage batteries Ni-Cd or LiFePO4
• Storage battery charging signal
• Luminaire status signal
• Compatible with specific Wireless luminaires
SIGNAL BOOSTER WIRELESS
Key features:
• Cooperation with Wireless luminaires
• Compatible with storage batteries Ni-Cd or LiFePO4
• Booster status signal
• Status signal related to communication with
RUBIC central unit
SMART VISIO APPLICATION
Key features:
• System status control
• System programming
• Event log readout and printout
• Calling test function
• Possible to read in plans
RUBIC UNA RW central unit has a built-in additional subordinate module with aerial intended to communicate with wireless luminaires. Every emergency
and evacuation luminaire must have a built-in aerial to communicate wirelessly. The aerial is located in a way that excludes a risk of additional interference
arising from operation of electronics. RUBIC UNA Wireless has a touch panel and intuitive graphic menu so that you can easily configure the system without
using SmartVISIO application. Every RW address module has its own individual number/address. Addresses are assigned during manufacturing so it is not
necessary to provide any additional address programmer for installation and aintenance.
systems
114
RS
48
5m
ax
. 1
20
0m
LANmax. 100m
POTENTIAL FREE
CENTRAL BATTERY SYSTEM CBS
DES PANELSMART VISIO
MWB MODULE
2HDGS 3x2,5mm
POWER SUPPLY 230 VAC/216 VDC
TEST SIGNAL COMMUNICATION
POTENTIAL FREE
FIRE ALARM SYSTEM SIGNAL
VIZUALIZATION
DYNAMIC ESCAPE SYSTEM
Dynamic illumination is an innovative system controlling escape route depanding on situation present on facility. Due to connection with fire alarm systems,
marking allows to fast recognition of safe escape route. Rapidally changing conditions such as smoke or fire require system which allows fast and dynamic
change of the safest escape route.
The DES system cooperates with the CBS central battery system. Due to such solution dynamic luminaires are also powered during malfunction. Circuits
which power dynamic luminaires should be led with fire resistant 3 core cable.
Comunication between the dynamic luminaires and the control panel is done with the 3 core communication cable. The DES panel sends information about
active scenario to particular luminaires. There is also possibility to check automatically and completely if the installed luminaires work properly. The test
result is registered in a log file which is saved in non-volatile memory.
systems
115
Max 750luminaire
Max 250luminaire
Max 250luminaire
Max 250luminaire
MP 4
MP 16
Max 250luminaire
MP
U 2
50
p
ow
er
Ma
x 1
3
Dynamic luminaires may display up to 10 characters depanding on accepted scenerio. Additional function is running light mode. Scenarios are initiated
from panel on DES control unit and potential-free MWB input module which gathers signals from detection devices. Any time scenario changes maybe
done without any additional software.
Max 250
systems
116
FIRE ALARM SYSTEM FAS
Key features:
• Up to 7 supervisory loops
• Up to 250 elements per a loop
• Up to 250 supervisory zones per loop
• Outputs built-in:
• ATS
• Signal lines
• Fault
• Universal relay
• Maximum loop length 2000m
• Loop interval detection
• Events counter up to 15,000
• Expansion cards
• Conformity with EN 54-2, EN 54-4 standard
• 7-Inch touch screen
• Printer built-in
• BACnet, www interface
The FAS fire alarm system is an element of building security. The FAS is intended for detecting fire in the early phase. Modular construction allows to wide
extension and because of this to control large-size buildings. The main element of the system is central unit, which is responsible for receiving signals from
devices located on detection circuits and transferring to other executive devices co-creating the fire protection system of the building. Fire detectors are
automatic detection elements. They are equipped with heat or smoke detectors. Manual call points are intended for transmitting information about the fire
to the person who will notice it and manually activate the device. Input/Output modules are designed to cooperation with external fire protection devices or
systems, while signaling devices are used to alert people in the building about unsafe conditions.
ROUTER
BMS BUILDING
MANAGEMENT SYSTEM
NETWORK PC
systems
117 73
FAS SYSTEM ELEMENTS/COMPONENTS
EXTERNAL SIGNAL PANEL ESP
Key features:
• Double interface of the control unit
• 7-Inch touch screen
• 4 levels of access
• Multi-language service
• Access blockade by using a key
• Compact casing
FIRE DETECTORS
Key features:
• Conformity with EN 54-5 and 54-7 standard
• Regulation of alarm threshold which compensates
the influence of the environment
• Indication of an alarm by means of the LED diode
• Additional LED diodes for the testing state
• Integrated short-circuit isolator
• A casing with a low profile
MANUAL CALL POINT
Key features:
• Conformity with EN 54-11 standard
• The manual call point type A
• Supervision state possible to be restored
• Operation in the addressable systems
• Signalling diode
SIGNALLING DEVICE
Key features:
• Conformity with EN 54-3 and 54-23 standard
• Small dimensions
• LED signalling diodes
• Low consumption of current
• 4 or 16 sound patterns
• Adjusting the volume
• Double-sided short-circuit isolator built-in
INPUT/OUTPUT MODULES
Key features:
• Conformity with EN 54-18 standard
• MIO modules are equipped with potencial outputs for signaling devices
• MIO modules are equipped with free potencial inputs
• Integrated short-circuit isolator which allows quickly location of fault
• Two IP Rating casing type: IP66 or IP67
• Cooperate between fire-fighting devices and the AWEX FAS
• MIO modules are equipped with relay no monitored outputs
• MIO modules are equipped with relay monitored outputs
• MIO modules are equipped with potencial inputs
• Detection of test fire: from TF1 to TF9
systems
118
CENTRAL BATTERY SYSTEM FZLV
Central battery system FZLV is a high-tech device created to power
and monitor emergency lighting in buildings of small and medium size and
in closed fire zones. The system can work with up to 80 LED luminaires
supplied by SELV 24V (Safety Extra-Low Voltage) and was designed in
SMART technology.
The application of the SELV voltage ensures high level of safety of
servicing of the system and its elements are compilant with the currently
valid regulations. Small dimensions of the central unit enable the
installation of the system in places where one cannot fit a large-size central
battery system. The FZLV central unit is equipped with a big touch panel
enabling both the current reading of the status of the system, circuits and
fittings and the introduction of all settings and parameters of the system
with the use of the user interface. Statuses are displayed in both graphic
and text form. Using the central unit one can assign a name to the fitting
that will clearly help to identify the fittings installed in the system. Using the
central unit one can program and freely configure the emergency fittings
in constant, non-constant, switching and switching-dimming modes as well
as night work mode. The system has its own IP address and RJ45 slot which
is used for direct connection to Ethernet. With an built-in WEB module you
can directly access the system from any computer and print the event log
by using any web browser. Additionally, the system has an input and an SD
card that allows to record and upload system settings (back-up) and the
record of the reports of the Event Log in accordance with EN 50172.
FZLV - MAX 33/52 AhFZLV - 24 AhFZLV - 12 Ah
STAIRS
FIRE ZONEFIRE ZONE
FIRE ZONEFIRE ZONE
FIRE ZONEFIRE ZONE
PH90*
1....201....20
1....201....20
1....201....20
1....201....20
1....201....20
1....201....20
systems
119
Key features:
• Power supply and monitoring up to 80 individual LED fittings in SMART
technology
• Safe supply SELV 24V
• SMART technology – any mode of a fitting
• Easy to read, big LCD touch screen
• Easy and intuitive menu with simple icons
• Automated testing
• Automatic detection and adding of the fittings to the system
• Built-in WEB module
• Programming and configuration of the fittings directly from the system
• Communication with luminaires through the power supply cable
• SD slot and SD card for recording, transmission and printing emergency
lighting reports from any PC, in accordance with EN 50172
• Possibility to store the system settings (back – up) on SD card
• Contained security light mode (night operation)
• Possibility to control fittings and some functions of the system via
terminals 24V and 230V
• Testing of each fitting separately as well as group of fittings
• Internal rechargeable battery with a designed life of 10 years
• RJ45 slot for direct connection to Ethernet
• Individual IP address
• Preview of the system via any web browser
• Works with any BMS (Building Management System) by using the
module of potential-free contacts or a ModBus
• Unlimited grouping of systems and joint supervision by Smart Touch
Controller
• Programmable emergency time operation for individual fixtures
STAIRS
FIRE ZONEFIRE ZONE
FIRE ZONEFIRE ZONE
FIRE ZONEFIRE ZONE
PH90*
1....201....20
1....201....20
1....201....20
1....201....20
1....201....20
1....201....20
ROUTER
ACCESS POINT
INTERNET
MAX 100m
MA
X 1
00
m
MA
X 1
00
m
MA
X 1
00
m
MA
X 1
00
m
MA
X 1
00
m
MA
X 1
00
mSMART VISIO SMART VISIOWEB
systems
120
The Central Battery System SPS provides emergency power supply
when the mains power is lost or its parameters are inappropriate. The
main purpose of the system is to supply power to emergency lighting
luminaires and assure 100% of the power for at least 1 hour. The lighting
which uses LED luminaires, fluorescent luminaires or compact fluorescent
luminaires can combine them in the same system. It is possible to connect
any type of luminaire and it is not necessary to install any additional
internal module. When designing the device, all applicable standards
were followed. The device is composed of an inverter which serves to
maintain the voltage of 230 VAC ± 3 % 50 Hz on output circuits. The system
is equipped with batteries whose capacity is dependent upon load and
emergency luminaire supply period.
The batteries are self-operating accumulators with a 10-year operation life.
SPS is based on the Offline technology, connected devices are supplied
directly from the mains. The supply voltage is regularly monitored and
in the event of a loss, the control system (after ca. 150 ms) disconnects
the mains power and switches into accumulator mode. The device is
secured against extensive load and short circuit. The circuit safety devices
are continuously monitored and the damage notification is displayed on
the front signaling panel. In spite of the simple structure, SPS has been
provided with a set of modern functions. The unit can be configured
and operated by means of the built-in www server and SmartVisio app
(optional). The use of all-purpose Modbus and BACnet protocols allows
integrating system from BMS. A small size of the cabinet allows installing
the system in places where large-size central battery systems do not fit.
SPS 600 SPS 1000 SPS 1500 SPS 2000
CENTRAL BATTERY SYSTEM SPS
SPS 300
FIRE ZONEFIRE ZONE
FIRE ZONEFIRE ZONE
FIRE ZONEFIRE ZONE
STAIRCASE PH90*
max 250 W
max 250 W
max 250 W
max 250 W
max 250 W
max 250 W
max 250 W
max 250 W
max 250 W
max 250 W
max 250 W
max 250 W
ma
x 2
50
W
ma
x 2
50
W
systems
121
The Central Battery System SPS is based on the Offline technology. Thanks to this technology, it is possible to minimize energy losses during mains
operation and thus increase durability and reduce operation costs. In practice, it is possible to supply devices connected to SPS directly from the mains.
During a normal mains operation, the system control unit and a unit responsible for monitoring accumulator parameters are supplied with power. The
supply voltage is monitored on a regular basis and in case of its loss (after about 150ms) the converter starts operating and converts the constant voltage
of 24 VDC from accumulators into alternating voltage for output (230 VAC 50 Hz sinus).
Advantages OFFLINE:
• Inconsiderable energy losses during mains power operation
• low working temperature
• increased system component durability
• low operation costs due to low damage rate
• low noise emission during mains operation
The diagram of the emergency supply central system SPS.
OFFLINE TECHNOLOGY – IF NEEDED
systems
122
CENTRAL BATTERY SYSTEM LPS
The LPS is a state-of-the-art, reliable and user-friendly central battery
system manufactured by AWEX. It has been designed to meet applicable
standards and comprises the proprietary SMART technology. From the
functional point of view, the LPS is equivalent to the CBS, however due to
its compact size and reduced power output it is intended for smaller-sized
locations or in places where the power sources of emergency luminaires
must be diversified (as a group). The LPS can power luminaires with a total
power output of 1500W for 1h or 500W for 3h. Thanks to four sensor
inputs provided in the control module, fire zones can be managed by
means of phase loss sensors (CZF) which monitor the voltage of the power
supplied to the zones, The system is upgradable with ELS230 modules
with 9 potential control inputs. Line modules have separate protection for
AC and DC mode, which considerably increases the safety of emergency
lighting activation in the building/facility. In the DC mode, the system
operates as an IT network (insulated).
System LPS
systems
123
Key features:
• LCD display with easy-to-use menu
• Automatic test performing
• Automatic detection and adding luminaires to the system
• Monitoring of each luminaire
• Monitoring of each circuit
• Programming and configuration of the luminaires directly from the
central unit
• Communication with luminaires through the power cable
• SMART technology – any mode of operation of the luminaire
• The linear modules are secured for the AC and DC mode separatelly
• SD card slot and card itself allow to save the periodic test results, event
log and system configuration
• Possibility to record the back-up of the system on the SD card
• Night mode operation
• Possibility to control luminaires and functions of the system through the
24V and 230V internal and external connectors
• Possibility to monitor power in the distribution boards and in the
separate lighting circuits
• RJ45 connector for direct communication with any computer via
Ethernet
• Preview of the system via any web browser
• Management and visualization of the system by using dedicated
software SMART VISIO
• Supply of the fixtures of total capacity 1500W for time 1h or 500W for 3h
LON
/LA
NLO
N/L
AN
LON
/LA
NS
UP
PLY
systems
124
CENTRAL BATTERY SYSTEM CBS
The CBS central battery system is state-of-the-art, reliable and easy-
to-operate central battery system constructed in accordance with the
requirements of VDE 0108 as well as EN 50171 and EN 50172 standards.
Due to the possibility of using sub-modules it is dedicated to medium and
large buildings and was designed in SMART technology.
The system monitors each output circuit individually and with the use
of address modules – each luminaire. The system allows any configuration
of mode both of the circuit and the luminaire. Using the driver one can
programme the mode of the address module without interfering into the
luminaire and without any specialized service software. The SD card slot
used in the system allows to perform a backup of the system and to save
the periodic test results, event log and system configuration, in accordance
with EN 50172. The event log can be printed out of the SD card on any
PC without any additional software. Besides, all the settings are stored in
non-volatile memory and will not be lost even during the complete power
supply and battery failure. The charger module ensures battery charging
based on UI characteristics with temperature compensation according
to EN 50171. The charger is equipped with internal active PFC module
which provides a power factor close to 1. Linear modules have separate
protection for AC and DC mode, significantly increasing the safety level
while switching on emergency lighting in the building. In DC mode the
system works in IT network layout (isolated system).
System CBS Standard
System CBS Compact
systems
125
Key features:
• LCD display with easy-to-use menu
• Automatic test performing
• Automatic detection and adding luminaires to the system
• Monitoring of each luminaire
• Monitoring of each circuit
• Programming and configuration of the luminaires directly from the
central unit
• Communication with luminaires through the power cable
• SMART technology – any mode of operation of the luminaire
• The linear modules are secured for the AC and DC mode separatelly
• SD card slot and card itself allow to save the periodic test results, event
log and system configuration,
• Possibility to record the back-up of the system on the SD card
• Night mode operation
• Possibility to control luminaires and functions of the system through the
24V and 230V internal and external connectors
• Possibility to monitor power in the distribution boards and in the
separate lighting circuits
• Possibility to use sub-modules in standard version and HUB version
• RJ45 connector for direct communication with any computer via
Ethernet
• Preview of the system via any web browser
• Battery set with 10 years life-time
• Works with any BMS (Building Management System) by using the
potential-free contacts or BacNet
• Management, supervision and visualization of entire system via
dedicated SMART VISIO software
PBS
SMART VISIOCBS Remote status panelPZS LON
MONITORING OFL1, L2, L3 230V
ELS-230 module
MONITORING OFL1, L2, L3 230V
Phase loss sensorCZF LON
MONITORING OFL1, L2, L3 230V
Phase loss sensor
CB/01/01 CB/01/02 CB/01/03 CB/01/n (n=MAX 20)
PBS/01/n (n=MAX 20)
PBS/02/n (n=MAX 20) PBS/02/03
PBS/01/03
PBS/02/02
PBS/01/02
PBS/02/01
PBS/02 – LUMINAIRE monitoringAC - 230V
BMS
AC - 230V
230V MAINS
LON
LON DC - 216V
LAN
PBS/01 – LUMINAIRE monitoring(mixed mode)
CB/02 CIRCUIT MONITORING
CB/02 circuit control signal
CB/01 LUMINAIRE monitoring(mixed mode)
PBS/01/01
Central battery circuits Central battery substation circuits
CB/02 (n=MAX 20 or 6A)
L=230V
systems
126
THE SMART VISIO PLATFORM
SMART VISO is an advanced control and monitoring application for the
latest emergency lighting systems manufactured by AWEX.
Irrespective of the chosen solution SMART VISIO enables connection,
integration and visualization of each system at the same time in any
configuration and at a single control desk. Thanks to the application
of the common BACnet protocol for system communication, the software
can be implemented virtually in any building. SMART VISIO is inexpensive
to install and offers the possibility of complete system visualization,
which saves time and costs of everyday supervision. The software is
recommended for use in shopping centres, medium and large office
buildings, hospitals, stadiums, airport terminals, manufacturing plants
and special purpose facilities. The system reporting complies with PN-EN
50172.
Key features:
• Compatibility with all other AWEX emergency lighting systems
• Intuitive menu
• Possibility to upload floor plans and luminaire layouts
• Automatic control of emergency lighting
• Unlimited configuration possibilities for individual luminaires and the
whole system from one place
• Luminaire and system status monitoring
• Possibility of installation on any Windows-based PC connected to
a common LAN
• Instant verification of any faults and system errors
• Quick identification of faulty devices
• Simple diagnostics of primary system parameters visualized in a block
diagram
• Possibility of system expansion by any number of connected
components
• Possibility of remote management of integrated systems
SWITCH
SMART VISIO APPLICATION
LANmax. 100m
LANmax. 100m
CBS LPS SPS FZLV RUBIC UNA / RUBIC UNA WIRELESS
PC
systems
127
The structure of the system is represented as a tree and as panels with
tabs. The order of elements is not set manually by a user, but is a result
of addressing. The number and contents of tabs depend on the element
of the system currently selected. Each element has a tab that displays its
status.
In the tree of the system, one of the systems can be selected and its status
will be shown on the panel. If the System is chosen, the status of all the
central units will be seen (icons change color the same way as on the plan
of the building). To change the current settings, use “Settings” tab.
RUBIC panel allows you to see the status of Rubic UNA or Rubic UNA MINI
central unit, as well as conversion kits and luminaires connected to it, to
see the results of tests, reports and configuration of the central unit. The
diagram displays the software version, serial number, status of inputs,
outputs, errors, lock, night work, power status, charger status, battery
status. Icons indicate the status of groups and sub-modules.
FZLV panel allows observation of the FZLV central unit and the luminaires
connected to it, viewing test results, reports, graphs and configuration of
the central unit. The diagram shows the hardware and software version,
serial number, status of inputs, outputs, errors, lock, night work, total
status of the central unit, power status, charger status, battery status,
circuit status.
CBS panel allows observation of status of the central battery, control unit,
charger, sensor modules, linear modules and luminaires, view test results,
reports. The diagram shows a view of the central battery cabinet. Modules
inside the cabinet can be moved by dragging the module with a mouse,
left button pressed. The control module is shown as CM (Control Module),
charger is shown as CH (Charger). The status of the groups (G1 – G255) is
displayed in the table named Steering Groups. The list displays the status
of the linear modules LM (Linear Module) and sensor modules SM (Sensor
Module).
additional components
ACCESSORIESBATTERIES PICTOGRAMSHTR 25 HEATER WITH THERMOSTAT
FOR LOW TEMPERATURE
130
BATTERIESACCESSORIES 132PICTOGRAMS
HTR 25 - HEATER WITH THERMOSTAT
131
134
additional components
130
HTR 25 - HEATER WITH THERMOSTAT FOR LOW TEMPERATURE
System HTR-25 allows our emergency lighting fixtures to work in up to
-25°C, which makes our products suitable for installation in cold rooms,
parkings and outside of the buildings where self-contained emergency
lighting fixtures are exposed to low temperatures.
This innovative solution can be used with both NiCd and Ni-MH battery
packs, with fluorescent tubes and with LED’s. HTR-25 is suitable for AWEX’s
IP65 fixtures and for our conversion kits assembled in IP65 commercial
lighting.
TECHNICAL SPECIFICATION:
Power supply: 230 VAC/50 Hz
Insulation class: I
Minimal ambient temperature: -25°C
Minimal battery temperature: +6°C
Heater initiation temperature: <10°C
L
N
PE
1
4
3
2
Legend:
1. Thermostat NO – closing temperature 10°C ±5°C – assembled inside the fixture
2. Thermostat NC – opening temperature 60°C ± 5°C – assembled on the battery
3. Self-regulated heating wire
4. Battery pack
CODE BATTERY CAPACITY BATTERY TYPE
HTR-25/3.6-1000-CD 3.6V 1000mAh Ni-Cd
HTR-25/3.6-1500-CD 3.6V 1500mAh Ni-Cd
HTR-25/3.6-2500-CD 3.6V 2500mAh Ni-Cd
HTR-25/3.6-4000-CD 3.6V 4000mAh Ni-Cd
HTR-25/4.8-1500-CD 4.8V 1500mAh Ni-Cd
HTR-25/4.8-2500-CD 4.8V 2500mAh Ni-Cd
HTR-25/4.8-4000-CD 4.8V 4000mAh Ni-Cd
HTR-25/6.0-1500-CD 6.0V 1500mAh Ni-Cd
HTR-25/6.0-2500-CD 6.0V 2500mAh Ni-Cd
HTR-25/6.0-4000-CD 6.0V 4000mAh Ni-Cd
CODE BATTERY CAPACITY BATTERY TYPE
HTR-25/3.6-1000-MH 3.6V 1000mAh Ni-MH
HTR-25/3.6-1500-MH 3.6V 1500mAh Ni-MH
HTR-25/3.6-2500-MH 3.6V 2500mAh Ni-MH
HTR-25/3.6-4000-MH 3.6V 4000mAh Ni-MH
HTR-25/4.8-1500-MH 4.8V 1500mAh Ni-MH
HTR-25/4.8-2500-MH 4.8V 2500mAh Ni-MH
HTR-25/4.8-4000-MH 4.8V 4000mAh Ni-MH
HTR-25/6.0-1500-MH 6.0V 1500mAh Ni-MH
HTR-25/6.0-2500-MH 6.0V 2500mAh Ni-MH
HTR-25/6.0-4000-MH 6.0V 4000mAh Ni-MH
CODE BATTERY CAPACITY BATTERY TYPE
HTR-25/6.4-1000-Li 6.4V 1000mAh LiFePO4
HTR-25/6.4-1500-Li 6.4V 1500mAh LiFePO4
HTR-25/6.4-3000-Li 6.4V 3000mAh LiFePO4
HTR-25/9.6-1500-Li 9.6V 1500mAh LiFePO4
HTR 25 heating system type is designed for installation in luminaires with a degree of IP65 or higher.
ORDER CODES
additional components
131
BATTERIES
CODE CAPACITY [mAh] VOLTAGE [V]DIMENSIONS [mm]
A x B x C x D x E x FWEIGHT [Kg]
Ni-Cd
1000
3.6
153x179x18x15x14x4 0,076
1500 136x162x25x22x18x4 0,14
2500 152x178x30x26x20x4 0,21
4000 189x210x30x33x25x4 0,352
Ni-Cd
1500
4.8
175x202x25x22x18x4 0,184
2500 202x228x30x26x20x4 0,288
4000 245x270x36x33x25x4 0,452
Ni-Cd
1500
6.0
218x244x25x22x18x4 0,228
2500 248x275x30x26x20x4 0,354
4000 303x329x36x33x25x4 0,574
Ni-MH
1500
3.6
153x179x18x15x14x4 0,088
2500 136x162x25xx22x18x4 0,172
4000 152x179x30x26x20x4 0,26
Ni-MH
1500
4.8
202x228x18x15x14x4 0,114
2500 175x202x25x22x18x4 0,22
4000 202x228x30x26x20x4 0,338
Ni-MH
1500
6.0
251x276x18x15x14x4 0,14
2500 220x246x26x23x18x4 0,268
4000 251x276x30x26x20x4 0,398
1000
LiFePO4
6.4
105x135x31x19x20x4 0,09
1500 135x165x31x19x20x4 0,112
3000 140x170x31x27x20x4 0,197
LiFePO 15004
9.6 203x233x31x19x20x4 0,152
A
B
C
F
E
D
additional components
132
256
77
41,5
ACCESSORIES
NAME/CODE PICTURE TECHNICAL DRAWING APPLICATION
CEILING BRACKETCODE:
1902 – HELIOS1903 – EXIT S1904 – EXIT M1905 – EXIT L
WALL BRACKETCODE:
1901 – HELIOS1906 – EXIT S1907 – EXIT M1908 – EXIT L
CEILING BRACKET WITH PIPECODE:
2944 – HELIOS2945 – EXIT S2946 – EXIT M2947 – EXIT L
ADJUSTABLE HANDLE 0-90° CODE: 3001
EXIT M, EXIT L
WALL BRACKET 90°CODE: 1009
TWINS
SUSPENSION ROPESCODE: 1006
SCREEN DS, TWINS, ARROW
WIRE GUARDCODE:
1003 – HELIOS1012 – EXIT S1013 – EXIT M1014 – EXIT L
ACCESORY FORRECESSED MOUNTING
CODE: IF2/RECINFINITY II
CONCRETE BOXCODE: IF2/RWC
INFINITY II
A
B
C
A
B
C
35 57
47
A
B C
12
0
268
10
0
37
12
0325
HELIOS, EXIT S, EXIT M, EXIT LDimensions (mm): (AxBxC):Helios: 405x100x170EXIT S: 250x55x147EXIT M: 310x55x197EXIT L: 410x80x205
HELIOS, EXIT S, EXIT M, EXIT LDimensions (mm): (AxBxC):Helios: 300x128x30 EXIT S: 202x121x26 EXIT M: 250x142x33EXIT L: 300x172x33
HELIOS, EXIT S, EXIT M, EXIT LDimensions (mm): (AxBxC):Helios: 300x128x435EXIT S: 202x121x428EXIT M: 250x142x449EXIT L: 300x172x479
HELIOS, EXIT S, EXIT M, EXIT LDimensions (mm): (AxBxC):Helios: 300x128x30 EXIT S: 202x121x26 EXIT M: 250x142x33EXIT L: 300x172x33
additional components
133
NAME/CODE PICTURE TECHNICAL DRAWING APPLICATION
UM BOXCODE: UM/BOX
UNILED UM
ACCESORY FORRECESSED MOUNTING
CODE: SK8/REC
SK-8
ACCESORY FORRECESSED MOUNTING
(SET)CODE:
ETS/REC – EXIT SETE/REC – EXIT METL/REC – EXIT L
EXIT S, EXIT M, EXIT L
Dimensions:(AxBxC):EXIT S: 36x36x1,5EXIT M: 42x31x1,5EXIT L: 37x34x1,5
ACCESORY FORPENDANT MOUNTING
CODE: ETE/PENEXIT S, EXIT M, EXIT L
PLEXI GLASS(SET)
CODE: ETE/PLXEXIT M
PLEXI GLASS(SET)
CODE:ETS/PLX - EXIT SETL/PLX - EXIT L
EXIT S, EXIT LDimensions:(AxBxC):EXIT S: 224x107x6EXIT L: 330x155x8
232
37
72
300
13
0
8
A
B
C
344
75
370
A
B
C
15
1000
30
1,50
ARROW N
ACCESORY FORRECESSED MOUNTING
(SET)CODE: EDGS/REC
EDGE S
320 39
32
0
300
40
90
TRACK LIGHTING
(SET)CODE: ARN/EUT
INSTALLATION ACCESSORY
additional components
134
PICTOGRAMS – STICKERS
22
25
28 61
23
26
24
27
Additional pictograms
Pictograms (compliant with PN-EN ISO 7010:2012)
Legend:xx – pictogram ID number (see the photos above)
Versatile pictogram sets (compliant with PN-EN ISO 7010:2012)
Arrow signs (compliant with PN-EN ISO 7010:2012)
31
33
41 42 43 44
32
*overall size
29
CODE PNxx PMxx PBxx PVxx PWxx
Dimensions [mm] 100x200 125x250 150x300 200x400 300x600
Compatible with: ETS ETE, HL, HEL, HDL, HDEL, ARN, ARP TW, IF2, SK8, ETL, EL SC40, SCS40 SC60, SCS60
34
CODE PU31 PU34
Dimensions [mm] 125x250 (125x375)* 100x200 (100x300)*
Compatible with: ETE, HEL, HL, HDL, HDEL, ARN, ARP
PU32
150x300 (150x450)*
TW, IF2, SK8, ETL, EL ETS
47
CODE PU41, PU42 PU43, PU44 PU47, PU48
Dimensions [mm] 125x125 150x150 100x100
Compatible with: ETE, HL, HEL, HDL, HDEL, ARN, ARP TW, IF2, SK8, ETL ETS
PSxx
100x300
TL, TG, TGS, TLS
PU33
100x300 (150x600)*
TL, TG, TGS, TLS
48
additional components
135
Compliant with PN-EN ISO 7010:2012
PICTOGRAMS – FOIL
CODE PSxxF PDxxF PLxxF
Dimensions [mm] 125x250 150x300 150x300
Compatible with: ARN, ARP IF2, IK, IKP
Compliant with PN-EN ISO 7010:2012
PICTOGRAMS – PAINTED ON PLEXI
CODE PDxxyy
Dimensions [mm] 100x200 125x250 150x300 200x400 300x600
Compatible with: ETS/PLX ETE/PLX, HL, HEL, HDL, HDEL, ARN, ARP PL, TW, IF2, SK8, ETL/PLX, SC30, SCS30, EL SC40, SCS40 SC60, SCS60
Legend:
xx- pictogram ID number (see the photos of Pictograms - Stickers)
yy - luminary code
ETL
Information for readers
138USED SYMBOLS 165
USEDSYMBOLS
PHOTOMETRY
PHOTOMETRY
Information for readers
138
ETS – LED 1W, 2W, 3W
ETSR – LED 1W, 2W, 3W
ETSU – LED 1W, 2W, 3W
ETS 1W (130lm) min. 0,5lx
h [m] L1 L2
2,50 3,0 8,0
3,00 3,5 9,0
3,50 4,0 10,0
4,00 3,5 10,5
4,50 3,5 11,0
5,00 3,5 12,0
6,00 3,5 12,5
7,00 3,5 12,0
8,00 3,5 12,5
ETS 2W (265lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 10,0
3,00 4,0 10,5
3,50 4,0 11,5
4,00 4,5 13,0
4,50 4,5 14,0
5,00 4,5 14,0
6,00 4,5 15,0
7,00 4,5 16,0
8,00 4,0 16,0
ETS 3W (360lm) min. 0,5lx
h [m] L1 L2
2,50 4,0 11,0
3,00 4,0 12,0
3,50 4,5 13,0
4,00 4,5 14,0
4,50 5,0 14,5
5,00 5,0 15,5
6,00 5,5 16,5
7,00 5,5 18,0
8,00 5,0 19,0
ETSR 1W (130lm) min. 1lx
h [m] L1 L2
2,50 5,5 12,5
3,00 6,0 14,5
3,50 6,5 15,5
4,00 6,5 17,0
4,50 4,0 15,0
ETSR 2W (265lm) min. 1lx
h [m] L1 L2
2,50 6,5 15,0
3,00 7,0 16,5
3,50 8,0 18,0
4,00 8,5 19,5
4,50 9,0 21,0
5,00 9,0 22,0
6,00 6,0 21,0
ETSR 3W (360lm) min. 1lx
h [m] L1 L2
2,50 7,0 16,5
3,00 7,0 17,5
3,50 8,5 19,0
4,00 9,0 20,5
4,50 10,0 22,0
5,00 10,0 23,5
6,00 10,5 26,5
ETSU 1W (150lm) min. 0,5lx
h [m] L1 L2
2,50 3,0 7,5
3,00 3,0 8,0
3,50 3,5 9,0
4,00 4,0 10,0
4,50 4,5 10,5
5,00 4,5 10,5
6,00 4,5 11,0
7,00 3,5 11,0
8,00 3,0 10,5
ETSU 1W (150lm) min. 1 lx
h [m] L1 L2
2,50 3,5 7,5
3,00 3,5 8,5
3,50 4,0 9,5
4,00 4,0 10,0
4,50 4,5 11,0
5,00 4,5 11,5
6,00 1,0 10,0
ETSU 2W (300lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 8,5
3,00 4,0 9,5
3,50 4,5 10,5
4,00 5,0 11,5
4,50 5,5 12,0
5,00 5,5 13,0
6,00 5,5 14,0
7,00 6,0 15,0
8,00 6,0 16,0
ETSU 2W (300lm) min. 1 lx
h [m] L1 L2
2,50 4,0 8,5
3,00 4,5 9,5
3,50 4,5 10,5
4,00 5,0 11,5
4,50 5,5 12,5
5,00 5,5 13,5
6,00 6,5 15,0
7,00 6,5 16,0
8,00 7,0 17,0
ETSU 3W (360lm) min. 0,5lx
h [m] L1 L2
2,50 4,0 9,0
3,00 4,5 10,0
3,50 5,0 11,0
4,00 5,0 11,5
4,50 5,5 12,5
5,00 5,5 13,5
6,00 6,0 15,0
7,00 6,5 16,5
8,00 7,0 18,5
ETSU 3W (425lm) min. 1 lx
h [m] L1 L2
2,50 4,0 9,0
3,00 4,5 10,0
3,50 5,0 11,0
4,00 5,5 12,0
4,50 6,0 14,0
5,00 6,0 14,0
6,00 6,5 15,5
7,00 7,0 17,0
8,00 7,5
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of EXIT S – ETS, ETSR, ETSU
L2L1
h
139
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of EXIT M – ETE
L2L1
h
ETE – LED 1W
ETE – LED 2W
ETE – LED 3W
ETE 1W (130lm) min. 1lx ETE 1W (130lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 8,0
3,00 3,0 8,5
3,50 3,0 9,0
4,00 3,0 9,0
4,50 3,5 9,5
5,00 3,0 9,5
6,00 2,0 8,5
h [m] L1 L2
2,50 2,5 8,5
3,00 2,5 9,0
3,50 3,0 10,0
4,00 3,0 10,5
4,50 3,0 10,5
5,00 3,0 11,0
6,00 2,5 12,0
ETE 2W (270lm) min. 1lx
h [m] L1 L2
2,50 4,5 10,5
3,00 4,0 11,5
3,50 4,0 12,0
4,00 4,5 12,5
4,50 4,5 13,5
5,00 4,5 14,0
6,00 4,5 15,0
7,00 5,0 15,5
8,00 4,5 15,5
9,00 4,0 15,0
10,00 3,5 14,5
ETE 2W (270lm) min. 0,5lx
h [m] L1 L2
2,50 4,0 10,0
3,00 4,5 12,5
3,50 4,5 11,5
4,00 4,5 12,0
4,50 4,5 12,5
5,00 4,5 13,5
6,00 4,5 13,5
7,00 4,5 14,0
8,00 4,0 13,5
9,00 3,0 13,5
10,00 2,0 13,0
ETE 3W (350lm) min. 1lx
h [m] L1 L2
2,50 4,5 10,5
3,00 4,0 11,5
3,50 5,0 12,5
4,00 5,0 13,5
4,50 5,0 13,5
5,00 5,5 14,0
6,00 5,5 15,0
7,00 5,5 15,5
8,00 5,0 15,5
9,00 4,5 15,0
10,00 3,5 15,0
ETE 3W (350lm) min. 0,5lx
h [m] L1 L2
2,50 4,0 11,0
3,00 4,0 11,5
3,50 4,5 13,0
4,00 4,5 14,0
4,50 4,5 14,5
5,00 4,5 15,5
6,00 5,0 16,5
7,00 5,5 18,0
8,00 5,5 18,5
9,00 5,0 19,5
10,00 4,5 20,5
Information for readers
140
ETL – LED 1W, 2W, 3W, 6WETL 1W (140lm) min. 0,5lx
h [m] L1 L2
2,50 2,5 8,5
3,00 2,5 9,5
3,50 3,0 10,0
4,00 3,0 10,5
4,50 3,0 11,0
5,00 3,0 11,5
6,00 3,5 12,0
7,00 3,0 13,0
8,00 2,5 13,0
ETL 2W (280lm) min. 0,5lx
h [m] L1 L2
2,50 3,0 10,0
3,00 3,5 11,0
3,50 4,0 12,0
4,00 4,0 13,0
4,50 4,0 13,5
5,00 4,0 14,5
6,00 4,5 15,5
7,00 45 16,5
8,00 4,5 17,5
9,00 4,5 18,0
10,00 4,0 19,0
ETL 3W (425lm) min. 0,5lx
h [m] L1 L2
2,50 4,0 11,0
3,00 4,0 12,0
3,50 4,0 13,0
4,00 4,5 14,0
4,50 4,5 15,0
5,00 5,0 16,0
6,00 5,5 17,5
7,00 5,5 18,5
8,00 5,5 20,0
9,00 5,5 20,5
10,00 5,5 21,5
ETL 6W (850lm) min. 0,5lx
h [m] L1 L2
4,00 5,5 16,5
4,50 6,0 18,0
5,00 6,0 19,0
6,00 6,5 21,0
7,00 7,0 22,5
8,00 7,5 24,0
9,00 7,5 25,5
10,0 8,0 26,5
11,0 8,0 27,5
12,0 8,0 28,5
ETL 3W (425lm) min. 1lx
h [m] L1 L2
2,50 4,5 11,0
3,00 5,0 12,0
3,50 5,5 13,0
4,00 5,5 13,5
4,50 6,0 14,5
5,00 6,0 15,0
6,00 6,0 16,0
7,00 6,0 16,5
8,00 6,0 17,0
9,00 5,5 17,0
10,00 5,0 17,0
ETL 1W (140lm) min. 1lx
h [m] L1 L2
2,50 3,0 8,0
3,00 3,5 8,5
3,50 3,5 9,0
4,00 3,5 9,5
4,50 3,5 9,5
5,00 3,5 9,5
6,00 3,0 9,0
7,00 2,0 9,0
ETL 6W (850lm) min. 1lx
h [m] L1 L2
4,00 7,0 16,5
4,50 7,5 17,5
5,00 7,5 18,5
6,00 8,0 20,0
7,00 8,5 21,5
8,00 8,5 22,5
9,00 8,5 23,0
10,0 8,5 24,0
11,0 8,5 24,0
12,0 8,0 24,5
ETL 2W (280lm) min. 1lx
h [m] L1 L2
2,50 4,0 10,0
3,00 4,5 10,5
3,50 4,5 11,5
4,00 4,5 12,0
4,50 5,0 12,5
5,00 5,0 13,0
6,00 5,0 13,0
7,00 4,5 14,0
8,00 4,0 14,0
9,00 3,5 13,5
10,00 2,5 13,0
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of EXIT L – ETL
L2L1
h
Information for readers
141
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of HELIOS LED – HWM, HWD, HHP
L2L1
h
HWM – for 2,5 to 10 m
HWD – for 8 to 14m
HHP – for 2,5 to 14m wide range
HWM 3W (360lm) min. 1lx
h [m] L1 L2
2,50 5,50 10,00
3,00 5,50 11,00
3,50 6,00 11,50
4,00 6,00 12,00
4,50 6,00 12,50
5,00 6,00 13,00
5,50 6,00 13,00
6,00 6,00 13,00
6,50 5,60 13,00
7,00 5,50 13,00
7,50 5,00 12,50
8,00 3,00 12,50
9,00 2,50 12,00
10,00 2,50 12,00
HWM 3W (360lm) min. 0,5lx
h [m] L1 L2
2,50 5,00 10,00
3,00 5,00 11,00
3,50 6,00 11,50
4,00 6,00 12,50
4,50 7,00 13,00
5,00 7,00 14,00
5,50 7,00 15,00
6,00 7,00 15,00
6,50 7,00 15,50
7,00 7,00 16,00
7,50 7,00 17,00
8,00 7,00 17,00
9,00 7,00 17,50
10,00 7,00 18,00
HWD 3x1W (370lm) min. 0,5lx
h [m] L1 L2
8,00 5,00 9,00
8,50 5,00 9,00
9,00 5,00 9,00
9,50 6,00 9,50
10,00 6,00 10,00
10,50 6,00 10,50
11,00 6,00 10,50
11,50 7,00 11,00
12,00 7,00 11,00
13,00 7,00 12,00
14,00 7,00 12,00
HWD 3x1W (370lm) min. 1lx
h [m] L1 L2
8,00 5,00 9,00
8,50 5,50 10,00
9,00 6,00 10,00
9,50 6,00 10,00
10,00 6,00 10,50
10,50 6,00 11,00
11,00 6,00 11,00
11,50 6,00 11,50
12,00 6,00 12,00
13,00 6,00 12,00
14,00 6,00 11,00
HHP 6x1W (920lm) min. 1lx
h [m] L1 L2
3,00 6,0 14,5
3,50 7,0 15,5
4,00 7,0 16,5
5,00 7,0 18,0
6,00 7,5 19,5
7,00 8,0 20,5
8,00 8,0 21,5
9,00 8,0 22,0
10,0 7,5 22,0
11,0 7,0 22,0
12,0 6,5 21,5
HHP 6x1W (920lm) min. 0,5lx
h [m] L1 L2
4,00 5,5 17,0
5,00 6,0 18,0
6,00 6,5 19,5
7,00 7,0 22,5
8,00 7,5 23,5
9,00 8,0 24,0
10,0 7,5 26,0
11,0 7,5 26,5
12,0 7,5 28,0
13,0 7,0 28,5
14,0 7,0 28,5
HHP 6x1W (920lm) avg. 10,8lx escape route
h [m] L1 L2
2,50 5,0 12,0
3,00 5,5 13,0
3,50 5,5 10,5
4,00 5,5 8,5
5,00 4,0 7,5
6,00 2,5 5,5
7,00 2,5 4,0
HHP 6x1W (920lm) avg. 10,8lx open area
h [m] L1 L2
2,50 3,0 8,0
3,00 3,5 8,0
3,50 2,5 8,0
4,00 2,5 7,5
5,00 1,5 7,5
6,00 1,5 7,0
70
140
210
280
0° 15°
30°
45°
60°
75°
90°
°501° 021° 081° 021° 501
90°
75°
60°
45°
30°
15°
BZ2
I(0°)=299cd/klm[ cd/klm]
C0-C180 C90-C270
=100%
70
140
210
280
3500° 15°
30°
45°
60°
75°
90°90°
75°
60°
45°
30°
15°
BZ2
I(0°)=347cd/klm[ cd/klm]
C0-C180 C90-C270
=99%
Information for readers
142
LV2R – with optics for escape route
LV2O – with optics for open area
LV2C - with optics for corridor
LV2R 1W (140lm) min. 1lx
h [m] L1 L2
2,50 6,0 14,0
3,00 6,5 15,5
3,50 7,0 17,0
4,00 6,5 18,0
LV2O 1W (140lm) min. 0,5lx
h [m] L1 L2
2,50 3,0 11,0
3,00 2,5 11,5
3,50 2,5 13,0
4,00 2,5 12,5
4,50 2,5 12,5
5,00 2,0 11,0
6,00 1,5 10,5
LV2C 1W (150lm) min.1lx
h [m] L1 L2
2,50 5,5 15,0
3,00 5,5 16,0
3,50 5,0 16,0
4,00 5,0 16,5
4,50 5,0 16,5
5,00 4,5 16,5
LV2R 2W (250lm) min. 1lx
h [m] L1 L2
2,50 7,0 16,0
3,00 7,5 17,5
3,50 8,0 19,0
4,00 9,0 21,0
4,50 9,5 22,5
5,00 9,5 24,0
6,00 9,5 25,0
LV2O 2W (270lm) min. 0,5lx
h [m] L1 L2
2,50 5,0 16,5
3,00 5,0 16,5
3,50 4,5 17,0
4,00 4,0 17,0
4,50 4,0 17,0
5,00 3,5 17,0
6,00 3,5 16,0
LV2C 2W (240lm) min.1lx
h [m] L1 L2
2,50 6,5 17,5
3,00 7,0 19,0
3,50 7,0 19,0
4,00 7,0 19,5
4,50 7,0 19,5
5,00 6,5 20,0
6,00 6,5 20,5
7,00 6,5 21,0
LV2R 3W (370lm) min. 1lx
h [m] L1 L2
2,50 7,5 17,0
3,00 8,0 18,5
3,50 9,0 20,0
4,00 9,5 22,0
4,50 10,0 23,5
5,00 10,5 25,0
6,00 10,5 27,0
LV2O 3W (390lm) min. 0,5lx
h [m] L1 L2
2,50 5,0 18,0
3,00 5,0 18,0
3,50 4,5 18,0
4,00 4,5 18,5
4,50 4,0 20,0
5,00 3,5 20,0
6,00 3,,5 19,5
7,00 4,0 18,5
8,00 4,0 18,0
LV2C 3W (360lm) min.1lx
h [m] L1 L2
2,50 7,5 19,0
3,00 8,0 20,5
3,50 8,5 21,0
4,00 9,0 23,0
4,50 9,0 24,0
5,00 9,5 25,0
6,00 10,0 26,0
7,00 10,0 28,0
8,00 9,5 29,0
400
800
1200
400
0° 15° 30°
45°
60°
75°
90°
105°
120°
150° 135°135° 150° 180°
120°
105°
90°
75°
60°
45°
30° 15°
BZ5
I(0°)=107cd/kl cd/klm]
C0-C180 C90-C270
=100%
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of LOVATO 2 – LV2C, LV2R, LV2O, LV2U, LV2A
L2L1
h
Information for readers
143
LV2U – with universal optics
LV2A – with asymmetric optics
LV2U 2W (270lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 7,5
3,00 3,5 9,0
3,50 4,0 10,0
4,00 4,5 11,0
4,50 4,5 12,0
5,00 5,0 12,5
6,00 5,5 13,5
LV2A 2W (280lm) min. 1lx
h [m] L1 L2
2,50 5,0 12,0
3,00 5,0 13,0
3,50 4,0 14,0
4,00 4,0 13,5
4,50 3,5 13,5
5,00 3,5 11,5
6,00 3,0 10,0
7,00 3,0 8,0
8,00 2,0 8,0
LV2U 3W (390lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 8,5
3,00 4,0 9,5
3,50 4,0 10,5
4,00 5,0 11,0
4,50 5,5 12,5
5,00 5,5 13,5
6,00 6,0 15,0
LV2A 3W (370lm) min. 1lx
h [m] L1 L2
2,50 5,5 13,5
3,00 5,5 14,5
3,50 5,5 15,0
4,00 4,5 16,0
4,50 4,5 16,0
5,00 4,5 15,0
6,00 4,0 11,5
7,00 4,0 11,0
8,00 3,0 10,0
LV2U 1W (140lm) min. 0,5lx
h [m] L1 L2
2,50 3,0 7,0
3,00 3,5 7,5
3,50 3,5 8,5
4,00 4,0 9,5
4,50 4,0 10,0
5,00 4,0 10,5
6,00 4,0 10,5
LV2A 1W (140lm) min. 1lx
h [m] L1 L2
2,50 3,0 9,5
3,00 2,5 9,5
3,50 2,5 8,5
4,00 2,5 7,5
4,50 2,0 7,0
5,00 1,5 7,0
6,00 1,0 5,0
160
320
480
640
0° 15° 30°
45°
60°
75°
90°
105°105°
90°
75°
60°
45°
30° 15°
BZ2
I(0°)=196cd/klm [cd/klm]
C0-C180 C90-C270
150° 135°135° 150° 180°
=100%
Information for readers
144
LVPR – with optics for escape route
LV2O – with optics for open area
LVPC - with optics for corridor
LVPR 1W (150lm) min. 1lx
h [m] L1 L2
2,50 5,0 11,0
3,00 5,5 13,0
3,50 6,0 14,0
4,00 6,5 15,0
LVPC 1W (150lm) min.1lx
h [m] L1 L2
2,50 6,0 14,5
3,00 6,5 16,0
3,50 6,5 17,0
4,00 7,0 17,5
4,50 7,0 18,0
5,00 7,0 17,5
6,00 6,5 15,0
LVPO 1W (140lm) min.0,5lx
h [m] L1 L2
2,50 4,0 10,5
3,00 4,5 11,5
3,50 5,0 13,0
4,00 2,5 12,0
4,50 2,0 11,5
5,00 2,5 11,0
6,00 2,0 10,0
LVPR 2W (270lm) min. 1lx
h [m] L1 L2
2,50 6,0 13,0
3,00 6,5 14,5
3,50 7,0 16,0
4,00 7,5 17,5
4,50 8,0 18,5
5,00 8,5 19,5
6,00 9,0 20,0
LVPC 2W (270lm) min.1lx
h [m] L1 L2
2,50 6,5 16,0
3,00 7,5 18,0
3,50 8,0 20,0
4,00 8,0 21,0
4,50 8,5 22,0
5,00 9,0 24,5
6,00 9,5 25,0
7,00 10,0 26,0
LVPO 2W (270lm) min.0,5lx
h [m] L1 L2
2,50 5,0 11,5
3,00 5,5 12,5
3,50 6,0 14,5
4,00 6,5 16,0
4,50 7,0 16,5
5,00 6,5 14,5
6,00 2,5 14,0
7,00 2,5 13,5
8,00 2,0 13,0
LVPR 3W (370lm) min. 1lx
h [m] L1 L2
2,50 6,0 14,0
3,00 6,5 15,5
3,50 7,5 17,0
4,00 8,0 18,0
4,50 9,0 20,0
5,00 9,0 21,0
6,00 9,0 21,5
LVPC 3W (350lm) min.1lx
h [m] L1 L2
2,50 7,0 16,0
3,00 8,0 18,5
3,50 9,0 21,0
4,00 9,5 22,5
4,50 10,0 25,0
5,00 10,5 26,5
6,00 11,0 27,0
7,00 11,5 28,0
8,00 11,0 28,0
LVPO 3W (360lm) min.0,5lx
h [m] L1 L2
2,50 5,0 12,0
3,00 5,5 13,0
3,50 6,5 15,5
4,00 7,0 16,5
4,50 7,5 18,0
5,00 8,0 19,5
6,00 4,0 18,0
7,00 2,5 18,0
8,00 2,5 17,5
400
800
1200
400
0° 15° 30°
45°
60°
75°
90°
105°
120°
°051° 531180°°531° 051
120°
105°
90°
75°
60°
45°
30° 15°
BZ4
I(0°)=94cd/klm [cd/klm]
C0-C180 C90-C270
=100%
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of LOVATO P – LVPC, LVPR, LVPO, LVPU, LVPA
L2L1
h
Information for readers
145
LVPU – with universal optics
LVPA – with asymmetric optics
LVPU 2W (280lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 7,5
3,00 4,0 8,0
3,50 4,0 9,0
4,00 4,5 9,5
4,50 5,0 10,0
5,00 5,0 11,0
6,00 5,5 11,0
LVPA 2W (270lm) min. 1lx
h [m] L1 L2
2,50 8,0 15,0
3,00 2,5 15,5
3,50 3,0 15,5
4,00 3,0 15,5
4,50 4,0 9,0
5,00 4,5 9,0
6,00 4,0 9,0
7,00 4,0 8,0
8,00 3,5 8,0
LVPU 3W (390lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 8,0
3,00 4,0 8,5
3,50 4,5 9,5
4,00 4,5 10,5
4,50 5,5 11,0
5,00 6,0 12,5
6,00 6,5 13,5
LVPA 3W (360lm) min. 1lx
h [m] L1 L2
2,50 9,0 21,5
3,00 3,0 18,5
3,50 3,0 18,0
4,00 3,0 18,0
4,50 3,0 17,5
5,00 4,0 11,0
6,00 4,5 11,0
7,00 4,0 11,0
8,00 4,0 10,5
LVPU 1W (150lm) min.0,5lx
h [m] L1 L2
2,50 3,0 6,5
3,00 3,0 7,0
3,50 3,5 7,5
4,00 3,5 8,5
4,50 4,0 8,5
5,00 4,5 9,0
6,00 4,5 8,0
LVPA 1W (140lm) min. 1lx
h [m] L1 L2
2,50 1,5 11,5
3,00 1,5 12,0
3,50 2,5 7,5
4,00 2,5 7,5
4,50 2,5 7,0
5,00 2,0 7,0
6,00 2,0 6,0
200
400
600
800
0° 15° 30°
45°
60°
75°
90°
105°
120°°531° 081
105°
90°
75°
60°
45°
30° 15°
BZ2
I(0°)=219cd/klm [cd/klm]
C0-C180 C90-C270
=100%
Information for readers
146
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of ARROW N - ARNS, ARNC, ARNO
L2L1
h
ARNS – without optics
ARNC – with optics for escape route
ARNO – with optics for open area
ARNS 1W (120lm) min.0,5lx
h [m] L1 L2
2,50 2,5 8,0
3,00 3,0 8,5
3,50 3,0 9,5
4,00 3,5 10,0
4,50 3,5 10,5
5,00 3,0 11,0
6,00 3,0 11,5
7,00 2,5 11,5
8,00 2,0 11,0
ARNS 2W (220lm) min.0,5lx
h [m] L1 L2
2,50 3,0 9,0
3,00 3,0 9,5
3,50 3,5 10,5
4,00 4,0 11,5
4,50 4,0 12,0
5,00 4,0 13,0
6,00 4,0 14,0
7,00 4,0 14,5
8,00 3,5 14,0
ARNC 3x1W (270lm) min.1lx
h [m] L1 L2
2,50 3,5 8,0
3,00 4,0 9,0
3,50 4,0 10,0
4,00 4,0 10,5
4,50 4,5 11,0
5,00 4,5 11,5
6,00 4,5 12,0
ARNO 3x1W (270lm) min.0,5lx
h [m] L1 L2
2,50 3,0 8,5
3,00 3,0 9,0
3,50 3,0 10,0
4,00 3,0 10,5
4,50 3,0 11,0
5,00 3,0 11,5
6,00 3,0 12,0
80
160
240
320
4000° 15°
30°
45°
60°
75°
90°90°
75°
60°
45°
30°
15°
BZ2
I(0°)=374cd/klm [cd/klm]
C0-C180 C90-C270
=100%
200
400
600
800
10000° 15°
30°
45°
60°
75°
90°90°
75°
60°
45°
30°
15°
BZ1
I(0°)=889cd/klm [cd/klm]
C0-C180 C90-C270
=100%
400
800
1200
1600
20000° 15°
30°
45°
60°
75°
90°90°
75°
60°
45°
30°
15°
BZ1
I(0°)=1694cd/klm [cd/klm]
C0-C180 C90-C270
=100%
Information for readers
147
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of ARROW P – ARPS, ARPC, ARPO
L2L1
h
ARPS – without optics
ARPC – with optics for escape route
ARPO – with optics for open area
ARPS 1W (120lm) min. 0,5lx
h [m] L1 L2
2,50 2,5 8,0
3,00 3,0 8,5
3,50 3,0 9,5
4,00 3,5 10,0
4,50 3,5 10,5
5,00 3,0 11,0
6,00 3,0 11,5
7,00 2,5 11,5
8,00 2,0 11,0
ARPS 2W (220lm) min. 0,5lx
h [m] L1 L2
2,50 3,0 9,0
3,00 3,0 9,5
3,50 3,5 10,5
4,00 4,0 11,5
4,50 3,0 12,0
5,00 3,0 13,0
6,00 2,0 14,0
7,00 2,0 14,5
8,00 2,0 14,0
ARPC 3x1W (270lm) min. 1lx
h [m] L1 L2
2,50 3,5 8,0
3,00 4,0 9,0
3,50 4,0 10,0
4,00 4,0 10,5
4,50 4,5 11,0
5,00 4,5 11,5
6,00 4,5 12,0
ARPO 3x1W (270lm) min. 0,5lx
h [m] L1 L2
2,50 3,0 8,5
3,00 3,0 9,0
3,50 3,0 10,0
4,00 3,0 10,5
4,50 3,0 11,0
5,00 3,0 11,5
6,00 3,0 12,0
80
160
240
320
4000° 15°
30°
45°
60°
75°
90°90°
75°
60°
45°
30°
15°
BZ2
I(0°)=374cd/klm [cd/klm]
C0-C180 C90-C270
=100%
200
400
600
800
10000° 15°
30°
45°
60°
75°
90°90°
75°
60°
45°
30°
15°
BZ1
I(0°)=889cd/klm [cd/klm]
C0-C180 C90-C270
=100%
400
800
1200
1600
20000° 15°
30°
45°
60°
75°
90°90°
75°
60°
45°
30°
15°
BZ1
I(0°)=1694cd/klm [cd/klm]
C0-C180 C90-C270
=100%
Information for readers
148
AXNC – with optics for corridor
AXNR – with optics for escape route
AXNO –with optics for opean area
AXNC 1W (150lm) min.1lx
h [m] L1 L2
2,50 5,5 15,0
3,00 5,5 16,0
3,50 6,0 16,0
4,00 6,0 16,5
4,50 5,5 16,0
5,00 5,0 16,0
6,00 5,0 13,0
AXNC 2W (260lm) min. 1lx
h [m] L1 L2
2,5 7,0 17,0
3,0 7,5 18,0
3,5 8,0 19,0
4,0 8,5 20,5
5,0 9,0 22,0
6,0 9,0 23,5
7,0 8,0 22,5
8,0 7,5 15,5
9,0 7,0 13,5
10,0 7,5 11,5
11,0 7,5 10,0
12,0 7,0 8,5
AXNR 1W (150lm) min. 1lx
h [m] L1 L2
2,50 5,5 12,0
3,00 6,5 13,5
3,50 7,0 15,0
4,00 7,5 17,0
AXNO 1W (145lm) min.0,5lx
h [m] L1 L2
2,50 2,5 14,0
3,00 2,0 13,5
3,50 2,0 13,5
4,00 2,0 13,0
4,50 1,5 12,5
5,00 1,5 12,5
6,00 1,5 12,0
AXNO 2W (250lm) min. 0,5lx
h [m] L1 L2
2,5 3,5 14,0
3,0 2,5 13,5
3,5 2,0 13,5
4,0 2,5 13,0
5,0 2,0 12,5
6,0 2,0 12,5
7,0 2,0 12,0
8,0 2,0 2,0
9,0 2,0 1,5
10,0 2,0 1,5
11,0 1,5 1,5
AXNC 3W (360lm) min.1lx
h [m] L1 L2
2,50 8,0 19,0
3,00 8,0 20,0
3,50 8,5 21,0
4,00 9,0 22,5
4,50 9,5 24,0
5,00 10 25,0
6,00 10,5 26,0
7,00 10,0 27,0
8,00 9,5 27,0
9,00 9,0 21,0
10,00 8,5 17,0
AXNR 2W (250lm) min. 1lx
h [m] L1 L2
2,50 5,5 13,0
3,00 6,5 14,5
3,50 7,5 16,5
4,00 8,5 18,0
4,50 9,0 20,0
5,00 10,0 21,0
AXNO 3W (350lm) min.0,5lx
h [m] L1 L2
2,50 5,0 17,5
3,00 4,5 17,5
3,50 4,0 19,0
4,00 3,5 19,0
4,50 3,0 20,0
5,00 3,0 20,0
6,00 2,0 20,0
7,00 2,0 20,0
8,00 2,0 19,0
AXNR 6W (600lm) min. 1lx
h [m] L1 L2
2,50 7,5 20,0
3,00 8,5 21,0
3,50 9,5 21,5
4,00 10,5 22,5
4,50 11,0 23,5
5,00 11,5 25,0
6,00 13,0 29,0
AXNR 3W (370lm) min. 1lx
h [m] L1 L2
2,50 6,0 15,0
3,00 7,0 15,5
3,50 8,0 17,0
4,00 8,5 19,0
4,50 9,5 20,5
5,00 10,5 22,0
6,00 11,5 25,0
AXNO 6W (590lm) min.0,5lx
h [m] L1 L2
2,50 6,0 19,5
3,00 6,0 20,0
3,50 6,5 22,0
4,00 6,0 23,0
4,50 5,5 24,0
5,00 5,0 25,0
6,00 4,0 26,0
7,00 4,0 26,5
8,00 4,0 26,5
9,00 4,0 26,5
10,00 4,0 26,0
AXNC 6W (600lm) min.1lx
h [m] L1 L2
2,50 10,0 23,0
3,00 10,5 25,0
3,50 11,0 27,0
4,00 11,0 28,5
4,50 11,5 29,5
5,00 12,0 30,5
6,00 12,5 32,0
7,00 12,5 34,0
8,00 13,0 35,0
9,00 13,0 36,0
10,00 12,5 37,0
500
1000
1500
500
0° 15° 30°
45°
60°
75°
90°
105°
120°
150° 135°180°135° 150°
120°
105°
90°
75°
60°
45°
30° 15°
BZ5
I(0°)=103cd/kl cd/klm]
C0-C180 C90-C270
=100%
500
1000
1500
500
0° 15° 30°
45°
60°
75°
90°
105°
120°
150° 135°180°135° 150°
120°
105°
90°
75°
60°
45°
30° 15°
BZ5
I(0°)=103cd/kl cd/klm]
C0-C180 C90-C270
=100%
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of AXN – AXNC, AXNR, AXNO, AXNU, AXNA
L2L1
h
Information for readers
149
AXNU – with universal optics
AXNA – with asymmetric optics AXNA 1W (140lm) min. 1lx
h [m] L1 L2
2,50 2,5 10,0
3,00 2,5 8,5
3,50 2,0 7,5
4,00 1,5 7,0
AXNA 2W (260lm) min. 1lx
h [m] L1 L2
2,50 5,0 13,0
3,00 4,0 12,5
3,50 3,5 12,0
4,00 3,5 10,0
4,50 3,0 9,0
5,00 3,0 8,0
6,00 2,0 7,0
AXNA 6W (580lm) min. 1lx
h [m] L1 L2
2,50 7,5 19,5
3,00 7,5 20,5
3,50 7,0 21,0
4,00 6,0 21,0
4,50 5,5 21,0
5,00 5,0 20,0
6,00 4,5 16,0
AXNU 6W (620lm) min. 0,5lx
h [m] L1 L2
2,50 4,0 8,5
3,00 4,0 9,5
3,50 4,5 10,5
4,00 5,0 11,0
4,50 5,5 12,0
5,00 6,0 13,0
6,00 7,0 14,0
AXNU 2W (270lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 7,5
3,00 4,0 8,0
3,50 4,0 9,0
4,00 4,5 10,0
4,50 5,0 11,0
5,00 5,0 11,0
6,00 5,5 11,0
AXNA 3W (380lm) min. 1lx
h [m] L1 L2
2,50 6,0 16,5
3,00 5,0 17,0
3,50 4,5 17,0
4,00 4,0 16,0
4,50 3,5 14,5
5,00 3,0 14,0
6,00 2,5 12,0
AXNU 3W (390lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 8,0
3,00 3,5 8,5
3,50 4,5 9,5
4,00 4,5 10,5
4,50 5,5 11,0
5,00 5,5 12,5
6,00 6,0 13,5
AXNU 1W (150lm) min.0,5lx
h [m] L1 L2
2,50 3,0 6,5
3,00 3,0 7,5
3,50 3,5 8,0
4,00 3,5 8,5
4,50 4,0 8,5
5,00 4,5 9,0
6,00 4,5 8,0
300
600
900
1200
0° 15°30°
45°
60°
75°
90°
105°120°135°180°105°
90°
75°
60°
45°
30°15°
BZ2
I(0°)=242cd/kl cd/klm]
C0-C180 C90-C270
=100%
160
320
160
320
0° 15° 30°45°
60°
75°
90°
105°
120°
135°150° 165°180°165° 150°135°
120°
105°
90°
75°
60°
45°30° 15°
BZ9
I(180°)=101cd/kl cd/klm]
C0-C180 C90-C270
=100%
Information for readers
150
AXPR – with optics for escape route
AXPO – with optics for open area
AXPC – with optics for corridor
AXPR 1W (150lm) min. 1lx
h [m] L1 L2
2,50 5,5 13,0
3,00 6,5 14,0
3,50 7,0 15,5
4,00 7,5 17,0
AXPO 1W (145lm) min. 0,5lx
h [m] L1 L2
2,50 2,5 13,5
3,00 2,0 13,5
3,50 2,0 13,5
4,00 2,0 13,0
4,50 1,5 12,5
5,00 1,5 12,5
6,00 1,5 12,0
AXPO 2W (260lm) min. 0,5lx
h [m] L1 L2
2,5 5,0 15,0
3,0 4,5 16,5
3,5 4,0 18,0
4,0 2,5 19,0
5,0 2,0 18,5
6,0 2,0 18,0
7,0 2,0 17,0
8,0 2,0 16,5
9,0 2,0 16,5
10,0 1,5 16,5
11,0 1,0 14,5
AXPC 1W (160lm) min. 1lx
h [m] L1 L2
2,50 5,5 15,0
3,00 5,5 16,0
3,50 6,0 16,5
4,00 6,5 17,0
4,50 6,0 16,5
5,00 6,0 16,5
6,00 5,5 14,0
AXPC 2W (260lm) min. 1lx
h [m] L1 L2
2,5 7,0 17,5
3,0 7,5 18,5
3,5 7,5 19,5
4,0 8,0 20,5
5,0 8,5 22,0
6,0 9,0 23,0
7,0 9,0 23,0
8,0 9,0 16,0
9,0 9,5 14,0
10,0 7,5 12,0
11,0 7,0 11,5
12,00 7,0 9,5
AXPR 2W (250lm) min. 1lx
h [m] L1 L2
2,50 6,0 14,0
3,00 7,0 15,0
3,50 7,5 17,5
4,00 8,5 19,0
4,50 9,0 20,0
5,00 9,5 21,0
6,00 10,0 22,0
AXPO 3W (375lm) min. 0,5lx
h [m] L1 L2
2,50 6,5 17,0
3,00 6,5 18,0
3,50 6,5 20,0
4,00 5,5 21,5
4,50 5,0 22,5
5,00 4,0 23,0
6,00 4,0 22,5
7,00 4,0 22,0
8,00 3,0 21,0
AXPC 3W (370lm) min. 1lx
h [m] L1 L2
2,50 8,0 19,0
3,00 8,0 20,5
3,50 8,5 21,5
4,00 9,0 23,0
4,50 9,5 24,0
5,00 10,0 25,0
6,00 10,5 26,5
7,00 10,5 28,0
8,00 10,0 27,5
AXPR 6W (600lm) min. 1lx
h [m] L1 L2
2,50 8,0 20,0
3,00 8,5 21,0
3,50 9,5 21,0
4,00 10,5 22,5
4,50 10,5 23,5
5,00 11,5 25,0
6,00 13,0 29,0
AXPR 3W (370lm) min. 1lx
h [m] L1 L2
2,50 6,5 16,5
3,00 7,5 17,5
3,50 8,0 19,0
4,00 9,0 20,5
4,50 9,0 22,0
5,00 10,5 22,5
6,00 10,5 23,5
AXPO 6W (615lm) min. 0,5lx
h [m] L1 L2
2,50 6,0 19,5
3,00 6,0 20,0
3,50 6,5 22,0
4,00 6,0 23,0
4,50 5,5 24,0
5,00 5,0 25,0
6,00 4,0 26,0
7,00 4,0 26,5
8,00 4,0 26,5
9,00 4,0 26,5
10,00 2,5 26,0
11,00 2,0 26,0
AXPC 6W (600lm) min. 1lx
h [m] L1 L2
2,50 10,0 23,0
3,00 10,5 25,5
3,50 11,0 27,0
4,00 11,5 29,0
4,50 12,0 30,0
5,00 12,0 31,0
6,00 12,5 32,0
7,00 13,5 35,0
8,00 14,0 36,0
9,00 14,5 37,0
10,00 14,5 38,0
500
1000
1500
500
0° 15° 30°
45°
60°
75°
90°
105°
120°
150° 135°180°135° 150°
120°
105°
90°
75°
60°
45°
30° 15°
BZ5
I(0°)=103cd/kl cd/klm]
C0-C180 C90-C270
=100%
500
1000
1500
500
0° 15° 30°
45°
60°
75°
90°
105°
120°
150° 135°180°135° 150°
120°
105°
90°
75°
60°
45°
30° 15°
BZ5
I(0°)=103cd/kl cd/klm]
C0-C180 C90-C270
=100%
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of AXP – AXPC, AXPR, AXPO, AXPU, AXPA
L2L1
h
Information for readers
151
AXPU – with universal optics
AXPA – with asymmetric optics AXPA 1W (140lm) min. 1lx
h [m] L1 L2
2,50 2,5 10,0
3,00 2,5 8,5
3,50 2,0 7,5
4,00 1,5 6,5
AXPA 2W (270lm) min. 1lx
h [m] L1 L2
2,50 5,0 13,0
3,00 4,0 12,5
3,50 3,5 12,0
4,00 3,5 10,0
4,50 3,0 9,0
5,00 3,0 8,0
6,00 2,0 7,0
AXPA 6W (580lm) min. 1lx
h [m] L1 L2
2,50 7,5 19,0
3,00 8,0 20,0
3,50 8,0 21,0
4,00 6,0 21,0
4,50 5,5 21,0
5,00 5,0 20,0
6,00 4,5 16,0
AXPU 6W (620lm) min. 0,5lx
h [m] L1 L2
2,50 4,0 8,5
3,00 4,5 9,5
3,50 4,5 10,5
4,00 5,5 10,5
4,50 5,5 12,0
5,00 6,0 13,0
6,00 7,0 14,0
AXPU 2W (270lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 7,5
3,00 4,0 8,0
3,50 4,0 9,0
4,00 4,5 10,0
4,50 5,0 11,0
5,00 5,0 11,0
6,00 5,5 11,0
AXPA 3W (380lm) min. 1lx
h [m] L1 L2
2,50 6,0 16,5
3,00 5,0 17,0
3,50 4,5 17,0
4,00 4,0 16,0
4,50 3,5 14,5
5,00 3,0 14,0
6,00 2,5 12,0
AXPU 3W (390lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 8,0
3,00 4,0 8,5
3,50 4,0 9,5
4,00 4,5 10,5
4,50 5,5 11,0
5,00 6,0 12,5
6,00 6,5 13,5
AXPU 1W (140lm) min.0,5lx
h [m] L1 L2
2,50 3,5 6,5
3,00 3,5 7,5
3,50 3,5 8,0
4,00 3,5 8,5
4,50 4,0 8,5
5,00 4,5 9,0
6,00 4,5 8,0
160
320
160
320
0° 15° 30°45°
60°
75°
90°
105°
120°
135°150° 165°180°165° 150°135°
120°
105°
90°
75°
60°
45°30° 15°
BZ9
I(180°)=101cd/kl cd/klm]
C0-C180 C90-C270
=100%
300
600
900
1200
0° 15°30°
45°
60°
75°
90°
105°120°135°180°105°
90°
75°
60°
45°
30°15°
BZ2
I(0°)=242cd/kl cd/klm]
C0-C180 C90-C270
=100%
Information for readers
152
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of EYE LED round – EYC, EYR, EYO, EYU, EY
L2L1
h
EYC – with optics for corridor
EYO - with optics for open area
EYC 1W (140lm) min. 1lx
h [m] L1 L2
2,50 6,0 14,0
3,00 6,0 15,0
3,50 6,5 16,0
4,00 6,5 17,0
EYC 2W (260lm) min. 1lx
h [m] L1 L2
2,50 7,0 17,0
3,00 7,5 18,0
3,50 8,0 20,0
4,00 8,0 21,0
4,50 8,5 22,0
5,00 8,5 23,0
6,00 9,0 24,5
EYC 3W (355lm) min. 1lx
h [m] L1 L2
2,50 7,5 18,0
3,00 8,0 19,5
3,50 9,0 21,0
4,00 9,5 22,5
4,50 10,0 24,0
5,00 10,5 25,0
6,00 10,5 27,0
400
800
1200
400
0° 15° 30°
45°
60°
75°
90°
105°
120°
°051° 531180°°531° 051
120°
105°
90°
75°
60°
45°
30° 15°
BZ5
I(0°)=90cd/klm [cd/klm]
C0-C180 C90-C270
=100%
EYR – with optics for escape route EYR 1W (140lm) min. 1lx
h [m] L1 L2
2,50 5,0 13,0
3,00 6,0 14,0
3,50 7,5 16,0
4,00 7,0 15,5
EYR 2W (260lm) min. 1lx
h [m] L1 L2
2,50 6,5 14,5
3,00 7,0 16,0
3,50 8,0 18,0
4,00 8,5 19,0
4,50 9,0 21,0
5,00 9,5 22,0
6,00 9,5 22,5
EYR 3W (350lm) min. 1lx
h [m] L1 L2
2,50 7,0 15,5
3,00 7,5 17,5
3,50 8,5 19,0
4,00 9,0 20,5
4,50 10,0 22,5
5,00 10,5 24,0
6,00 10,5 24,5
400
800
1200
400
0° 15° 30°
45°
60°
75°
90°
105°
120°
°051° 531180°°531° 051
120°
105°
90°
75°
60°
45°
30° 15°
BZ5
I(0°)=90cd/klm [cd/klm]
C0-C180 C90-C270
=100%
4,50 7,0 18,0
5,00 7,0 17,5
6,00 4,5 12,0
EYO 2W (260lm) min. 0,5lx
h [m] L1 L2
2,50 4,5 14,5
3,00 4,0 13,5
3,50 4,0 15,0
4,00 3,0 16,5
4,50 2,5 17,0
5,00 3,0 16,5
6,00 3,5 16,0
EYO 3W (350lm) min. 0,5lx
h [m] L1 L2
2,50 5,0 16,5
3,00 5,0 16,0
3,50 4,5 17,5
4,00 5,0 18,0
4,50 5,0 18,0
5,00 4,0 19,0
6,00 4,0 18,0
EYO 1W (135lm) min. 0,5lx
h [m] L1 L2
2,50 2,5 13,0
3,00 1,5 12,0
3,50 2,0 12,5
4,00 2,0 12,0
4,50 2,0 12,0
5,00 2,0 12,0
6,00 2,0 10,5
160
320
480
640
0° 15° 30°
45°
60°
75°
90°
105°
°531° 021180°°021° 531
105°
90°
75°
60°
45°
30° 15°
BZ2
I(0°)=220cd/klm [cd/klm]
C0-C180 C90-C270
=100%
Information for readers
153
EY - without optics EY 3x1W (360lm) – min. 0,5lx
h [m] L1 L2
2,50 3,5 9,5
3,00 3,5 10,0
3,50 4,5 11,5
4,00 4,5 12,0
4,50 5,0 14,5
5,00 5,0 14,5
6,00 5,5 15,0
7,00 5,0 15,0
8,00 5,5 17,5
EYU – with universal optics EYU 2W (270lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 7,5
3,00 3,5 8,0
3,50 4,0 9,0
4,00 4,5 10,0
4,50 4,5 11,5
5,00 5,0 12,0
6,00 5,5 13,0
EYU 3W (390lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 8,0
3,00 4,0 9,0
3,50 4,0 10,0
4,00 4,5 10,0
4,50 5,0 11,5
5,00 5,5 12,5
6,00 6,0 14,0
EYU 1W (150lm) min. 0,5lx
h [m] L1 L2
2,50 3,0 7,0
3,00 3,5 7,5
3,50 3,5 8,5
4,00 4,0 9,0
4,50 4,0 10,0
5,00 4,0 10,0
6,00 4,0 9,5
160
320
480
640
0° 15° 30°
45°
60°
75°
90°
105°
°531° 021180°°021° 531
105°
90°
75°
60°
45°
30° 15°
BZ2
I(0°)=220cd/klm [cd/klm]
C0-C180 C90-C270
=100%
Information for readers
154
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of EYE LED square – EYKC, EYKR, EYKO, EYKU, EYK
L2L1
h
EYKC – with optics for corridor
EYKO - with optics for open area
EYKC 1W (140lm) min. 1lx
h [m] L1 L2
2,50 6,0 14,0
3,00 6,0 15,0
3,50 6,5 16,0
4,00 6,5 17,0
EYKC 2W (260lm) min. 1lx
h [m] L1 L2
2,50 7,0 17,0
3,00 7,5 18,0
3,50 8,0 20,0
4,00 8,0 21,0
4,50 8,5 22,0
5,00 8,5 23,0
6,00 9,0 24,5
EYKC 3W (355lm) min. 1lx
h [m] L1 L2
2,50 7,5 18,0
3,00 8,0 19,5
3,50 9,0 21,0
4,00 9,5 22,5
4,50 10,0 24,0
5,00 10,5 25,0
6,00 10,5 27,0
400
800
1200
400
0° 15° 30°
45°
60°
75°
90°
105°
120°
°051° 531180°°531° 051
120°
105°
90°
75°
60°
45°
30° 15°
BZ5
I(0°)=90cd/klm [cd/klm]
C0-C180 C90-C270
=100%
EYKR – with optics for escape route EYKR 1W (140lm) min. 1lx
h [m] L1 L2
2,50 5,0 13,0
3,00 6,0 14,0
3,50 7,5 16,0
4,00 7,0 15,5
EYKR 2W (260lm) min. 1lx
h [m] L1 L2
2,50 6,5 14,5
3,00 7,0 16,0
3,50 8,0 18,0
4,00 8,5 19,0
4,50 9,0 21,0
5,00 9,5 22,0
6,00 9,5 22,5
EYKR 3W (350lm) min. 1lx
h [m] L1 L2
2,50 7,0 15,5
3,00 7,5 17,5
3,50 8,5 19,0
4,00 9,0 20,5
4,50 10,0 22,5
5,00 10,5 24,0
6,00 10,5 24,5
400
800
1200
400
0° 15° 30°
45°
60°
75°
90°
105°
120°
°051° 531180°°531° 051
120°
105°
90°
75°
60°
45°
30° 15°
BZ5
I(0°)=90cd/klm [cd/klm]
C0-C180 C90-C270
=100%
4,50 7,0 18,0
5,00 7,0 17,5
6,00 4,5 12,0
EYKO 2W (260lm) min. 0,5lx
h [m] L1 L2
2,50 4,5 14,5
3,00 4,0 13,5
3,50 4,0 15,0
4,00 3,0 16,5
4,50 2,5 17,0
5,00 3,0 16,5
6,00 3,5 16,0
EYKO 3W (350lm) min. 0,5lx
h [m] L1 L2
2,50 5,0 16,5
3,00 5,0 16,0
3,50 4,5 17,5
4,00 5,0 18,0
4,50 5,0 18,0
5,00 4,0 19,0
6,00 4,0 18,0
EYKO 1W (135lm) min. 0,5lx
h [m] L1 L2
2,50 2,5 13,0
3,00 1,5 12,0
3,50 2,0 12,5
4,00 2,0 12,0
4,50 2,0 12,0
5,00 2,0 12,0
6,00 2,0 10,5
160
320
480
640
0° 15° 30°
45°
60°
75°
90°
105°
°531° 021180°°021° 531
105°
90°
75°
60°
45°
30° 15°
BZ2
I(0°)=220cd/klm [cd/klm]
C0-C180 C90-C270
=100%
Information for readers
155
EYK - without optics EYK 3x1W (360lm) – min. 0,5lx
h [m] L1 L2
2,50 3,5 9,5
3,00 3,5 10,0
3,50 4,5 11,5
4,00 4,5 12,0
4,50 5,0 14,5
5,00 5,0 14,5
6,00 5,5 15,0
7,00 5,0 15,0
8,00 5,5 17,5
EYKU – with universal optics EYKU 2W (270lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 7,5
3,00 3,5 8,0
3,50 4,0 9,0
4,00 4,5 10,0
4,50 4,5 11,5
5,00 5,0 12,0
6,00 5,5 13,0
EYKU 3W (390lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 8,0
3,00 4,0 9,0
3,50 4,0 10,0
4,00 4,5 10,0
4,50 5,0 11,5
5,00 5,5 12,5
6,00 6,0 14,0
EYKU 1W (150lm) min. 0,5lx
h [m] L1 L2
2,50 3,0 7,0
3,00 3,5 7,5
3,50 3,5 8,5
4,00 4,0 9,0
4,50 4,0 10,0
5,00 4,0 10,0
6,00 4,0 9,5
160
320
480
640
0° 15° 30°
45°
60°
75°
90°
105°
°531° 021180°°021° 531
105°
90°
75°
60°
45°
30° 15°
BZ2
I(0°)=220cd/klm [cd/klm]
C0-C180 C90-C270
=100%
Information for readers
156
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of MICRO SPOT – MSU, MSR
L2L1
h
MSU 3W (380lm) min. 0,5lx
h [m] L1 L2
2,50 2,0 8,0
3,00 2,0 9,0
3,50 2,5 9,5
4,00 2,5 10,5
4,50 2,5 11,0
5,00 2,5 12,0
6,00 3,0 13,5
7,00 3,5 14,5
8,00 4,0 16,0
MSU 2W (260lm) min. 0,5lx
h [m] L1 L2
2,50 2,0 8,5
3,00 2,0 8,5
3,50 2,0 9,0
4,00 2,0 9,5
4,50 2,0 10,5
5,00 2,5 11,0
6,00 3,0 12,5
7,00 3,5 13,5
8,00 4,0 14,5
MSU - with universal optics
MSR - with optics for escape route
160
320
480
640
0° 15° 30°
45°
60°
75°
90°
105°120°180°135°
105°
90°
75°
60°
45°
30° 15°
BZ2
I(0°)=245cd/klm [cd/klm]
C0-C180 C90-C270
=100%
400
800
1200
400
0° 15° 30°
45°
60°
75°
90°
105°
120°
135°150°180°150°135°
120°
105°
90°
75°
60°
45°
30° 15°
BZ5
I(0°)=100cd/klm [cd/klm]
C0-C180 C90-C270
=100%
MSU 1W (140lm) min. 0,5lx
h [m] L1 L2
2,50 2,5 6,0
3,00 2,0 7,5
3,50 2,0 7,5
4,00 2,0 8,5
4,50 2,5 9,0
5,00 2,5 10,0
6,00 3,0 11,0
7,00 2,5 11,0
8,00 2,5 10,0
MSR 3W (360lm) min. 1lx
h [m] L1 L2
2,50 6,5 15,5
3,00 7,0 17,0
3,50 7,5 18,0
4,00 8,5 20,0
4,50 9,0 20,5
5,00 9,5 22,0
6,00 11,0 20,0
7,00 12,0 12,5
8,00 11,5 11,0
MSR 2W (250lm) min. 1lx
h [m] L1 L2
2,50 6,0 14,0
3,00 6,5 15,5
3,50 7,0 17,0
4,00 8,0 18,0
4,50 8,5 19,0
5,00 9,0 17,5
6,00 1,0 11,5
7,00 3,0 9,5
MSR 1W (130lm) min. 1lx
h [m] L1 L2
2,50 5,0 12,0
3,00 5,5 13,0
3,50 6,5 13,5
4,00 7,0 8,0
4,50 7,0 7,0
5,00 7,0 6,5
6,00 1,5 7,5
7,00 2,0 6,0
Information for readers
157
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of SPY 2 – SP2
L2L1
h
SP2 2W (250lm) min. 0,5lx
h [m] L1 L2
2,50 3,5 9,5
3,00 3,5 10,0
3,50 4,0 11,5
4,00 4,5 12,0
4,50 4,5 12,5
5,00 5,0 13,0
6,00 5,5 15,0
7,00 5,5 16,5
8,00 6,0 16,0
SP2 3W (360lm) min. 0,5lx
h [m] L1 L2
2,50 4,0 10,5
3,00 4,0 11,5
3,50 4,5 12,5
4,00 4,5 13,0
4,50 5,0 14,0
5,00 5,5 15,0
6,00 6,0 16,0
7,00 6,5 17,0
8,00 7,0 17,5
SP2 1W (140lm) min. 0,5lx
h [m] L1 L2
2,50 3,0 8,5
3,00 3,0 9,0
3,50 3,5 10,5
4,00 4,0 11,0
4,50 4,0 11,5
5,00 4,0 11,5
6,00 4,0 12,0
7,00 3,5 11,5
8,00 3,0 10,5
80
160
240
320
4000° 15°
30°
45°
60°
75°
90°90°
75°
60°
45°
30°
15°
BZ2
I(0°)=352cd/klm [cd/klm]
C0-C180 C90-C270
=100%
SP2 2W (250lm) min. 1lx
h [m] L1 L2
2,50 2,5 8,0
3,00 2,5 8,5
3,50 3,0 9,5
4,00 3,0 10,0
4,50 3,0 11,0
5,00 3,5 11,5
6,00 3,0 12,5
7,00 2,5 13,0
8,00 2,0 13,5
SP2 3W (360lm) min. 1lx
h [m] L1 L2
2,50 3,0 8,5
3,00 3,0 9,5
3,50 3,5 10,5
4,00 3,5 11,0
4,50 4,0 12,0
5,00 4,0 12,5
6,00 4,0 13,5
7,00 3,5 14,5
8,00 3,5 15,5
SP2 1W (140lm) min. 1lx
h [m] L1 L2
2,50 2,0 7,0
3,00 2,0 7,5
3,50 2,5 8,0
4,00 2,5 8,5
4,50 2,0 9,0
5,00 2,0 9,5
6,00 1,5 10,0
SP2 2W (250lm) min. 5lx
h [m] L1 L2
2,50 2,0 5,5
3,00 2,0 5,5
3,50 1,5 5,0
SP2 3W (360lm) min. 5lx
h [m] L1 L2
2,50 2,5 6,5
3,00 2,5 6,5
3,50 2,5 7,0
4,00 2,0 7,0
4,50 1,5 6,5
SP2 – without optics
Information for readers
158
EDGE R - EDRE12, EDRE18, EDRE24 EDGE R 3W (305lm) min. 0,5lx
h [m] L1 L2
2,5 3,5 10,5
3,0 3,5 12,0
3,5 3,5 12,5
4,0 4,0 13,5
5,0 4,0 15,0
6,0 4,0 16,0
7,0 4,5 17,0
8,0 4,5 18,0
9,0 4,5 19,0
10,0 4,0 19,5
11,0 3,5 20,0
12,0 3,5 20,0
13,0 2,5 20,5
14,0 2,0 21,0
EDGE R 3W (305lm) min. 1lx
h [m] L1 L2
2,5 4,0 10,0
3,0 4,5 11,0
3,5 4,5 11,5
4,0 4,5 12,5
5,0 5,0 13,5
6,0 5,0 14,0
7,0 4,5 14,0
8,0 4,5 14,0
9,0 3,5 14,0
10,0 2,5 13,5
11,0 1,0 12,5
*photometry of EDGE R 12W, 18W, 24W is the same
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of EDGE R – EDRE12, EDRE18, EDRE24
L2L1
h
Information for readers
159
EDGE S - EDSE12, EDSE18, EDSE24 EDGE S 3W (305lm) min. 0,5lx
h [m] L1 L2
2,5 3,5 10,5
3,0 3,5 12,0
3,5 3,5 12,5
4,0 4,0 13,5
5,0 4,0 15,0
6,0 4,0 16,0
7,0 4,5 17,0
8,0 4,5 18,0
9,0 4,5 19,0
10,0 4,0 19,5
11,0 3,5 20,0
12,0 3,5 20,0
13,0 2,5 20,5
14,0 2,0 21,0
EDGE S 3W (305lm) min. 1lx
h [m] L1 L2
2,5 4,0 10,0
3,0 4,5 11,0
3,5 4,5 11,5
4,0 4,5 12,5
5,0 5,0 13,5
6,0 5,0 14,0
7,0 4,5 14,0
8,0 4,5 14,0
9,0 3,5 14,0
10,0 2,5 13,5
11,0 1,0 12,5
*photometry of EDGE S 12W, 18W, 24W is the same
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of EDGE S – EDSE12, EDSE18, EDSE24
L2L1
h
Information for readers
160
Photometry of OUTDOOR LED – ODB
R2
R1
R'2
R'1
h
p1
R – radius of the illumination for avg. 5lx1
R ’ – distance from the wall for avg. 5lx1
R – radius of the illumination for avg. 1lx2
R ’ – distance from the wall for avg. 1lx2
h – assembly height of the fitting
p – max light intensity under the luminaire1
ODB 3x1W (360lm) min. 1lx and min. 5lx
h [m] - assemblyheight of the
fitting
p1 [lx] -max underthe fitting
R1 [m]for min.
5lx
R1’ [m]for min.
5lx
R2 [m]for min.
1lx
R2’ [m]for min.
1lx
2 30 4,2 3,0 6,9 5,5
2,2 25 4,4 3,0 7,1 5,7
2,4 21 4,4 3,1 7,4 5,8
2,6 18 4,4 3,1 7,6 6,0
2,8 15 4,3 3,1 7,8 6,1
3 13 4,1 3,0 8,0 6,2
3,2 11 4,0 3,0 8,4 6,3
3,4 10 3,7 2,9 8,6 6,4
3,6 9 3,4 2,8 8,9 6,5
ODB 3x1W
Information for readers
161
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
h – height of the ceiling
Photometry of TIGER LED – TL
L2L1
h
TL – transparent cover TL 3W (380lm) min 0,5lx
h [m] L1 L2
2,50 4,00 10,00
3,00 4,50 11,00
3,50 5,00 11,50
4,00 5,00 12,50
4,50 5,50 13,50
5,00 5,50 14,00
6,00 6,00 15,00
7,00 6,00 16,50
8,00 6,00 17,50
TL 3W (380lm) min. 1lx
h [m] L1 L2
2,50 4,00 10,00
3,00 4,00 10,50
3,50 4,00 11,00
4,00 4,00 11,00
4,50 4,50 11,50
5,00 4,50 12,00
6,00 4,50 13,00
7,00 4,50 13,50
8,00 4,50 13,50
Information for readers
162
Photometry of SK-8 – SK8
SK-8 3WSK8 3W (120lm) min. 1lx and min. 5lx
h [m] - assemblyheight of the
fitting
p1 [lx] -max underthe fitting
R1 [m]for min.
5lx
R1’ [m]for min.
5lx
R2 [m]for min.
1lx
R2’ [m]for min.
1lx
2 62 2,9 0,8 5,2 2,0
2,2 50 3,0 0,9 5,4 2,0
2,4 41 3,1 0,9 5,5 2,0
2,6 34 3,2 0,9 5,6 1,9
2,8 29 3,2 0,9 5,6 1,9
3 25 3,2 0,9 5,8 1,8
3,2 22 3,3 0,9 6,0 1,8
3,4 20 3,3 0,9 6,0 1,8
3,6 18 3,3 0,9 6,0 1,8
R2
R1
R'2
R'1
h
p1
R – radius of the illumination for avg. 5lx1
R ’ – distance from the wall for avg. 5lx1
R – radius of the illumination for avg. 1lx2
R ’ – distance from the wall for avg. 1lx2
h – assembly height of the fitting
p – max light intensity under the luminaire1
Information for readers
163
*photometry of IF2AWD, IF2ACD, IF2ALD is the same like IF2BWD
Photometry of INFINITY II – IF2BWD, IF2AWD, IF2ACD, IF2ALD
IF2BWD - with floor illumination systemIF2BWD 3W (80lm) min. 1lx and min. 5lx
h [m] - assemblyheight of the
fitting
p1 [lx] -max underthe fitting
R1 [m]for min.
5lx
R1’ [m]for min.
5lx
R2 [m]for min.
1lx
R2’ [m]for min.
1lx
2 13 2,9 0,9 5,7 2,2
2,2 11 2,7 0,9 6,0 2,1
2,4 8,5 2,5 0,9 6,1 1,8
2,6 7,5 2,2 0,8 6,3 1,8
2,8 6,5 1,8 0,7 6,4 1,8
3 5,5 1,1 0,5 6,5 1,8
3,2 4,5 – – 6,5 1,8
3,4 4,0 – – 6,6 1,8
3,6 3,5 – – 6,6 1,9
R2
R1
R'2
R'1
h
p1
R – radius of the illumination for avg. 5lx1
R ’ – distance from the wall for avg. 5lx1
R – radius of the illumination for avg. 1lx2
R ’ – distance from the wall for avg. 1lx2
h – assembly height of the fitting
p – max light intensity under the luminaire1
Information for readers
Information for readers
164
USED SYMBOLS
24VDC
d=25m
Ni-Cd
LED
IP65176-275V
DC
G5
T5
220-240VAC
50-60Hz
Light source type – LEDThe product meets the requirements in accordance with
the European Directive
Light source type – fluorescent lamp T5The permissible range of AC input voltage
Protection class – IP65The permissible range of DC input voltage
Mounting of emergency escape lighting fittings – surface / ceilingSafety extra low voltage SELV
Mounting of emergency escape lighting fittings – recessed / ceilingInsulation class I
Mounting of emergency exit signs – recessed / ceilingInsulation class II
Mounting of emergency exit signs – surface / ceilingInsulation class III
Viewing distance d=25mType of used battery
Current list of products with ENEC
is available at www.awex.eu
Current list of products with Kitemark
is available at www.awex.eu
Adaptation of the fixture for low temperatures up to -25°C
1pc. of universal pictogram is included in
each single box, other must be chosen
Photographs and parameters of the products shown in this catalogue are for reference only and cannot be relied upon as a legal offer. Certain parame-
ters of supplied products may differ from the parameters of the products described in this catalogue. The appearance of actual products may slightly
differ from the photographs and drawings contained in this catalogue. P.P.H.U AWEX reserves the right to discontinue products shown in this catalogue
or to modify their parameter without notice.
*see pictogramKM 61835 BS-EN
AWEX SP. Z O.O. SPÓŁKA KOMANDYTOWAMasłomiąca, ul. Długa 3932-091 Michałowice, Polandtel. +48 12 681 55 00fax. +48 12 681 55 22e-mail: [email protected]: awex.eu
Distributor