Nokia Siemens Networks
WCDMA RAN, Rel. RU30,
Operating Documentation,Issue 01
Troubleshooting AXC
DN02166669
Issue 25AApproval Date 2009-12-14
Confidential
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 2/42
2 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805807391b2
Confidential
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-
TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-
RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2009. All rights reserved
f Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment.
Some of the parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal
injury or in property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected
has to comply with the applicable safety standards.
The same text in German:
Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Span-
nung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverlet-
zungen und Sachschäden führen.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die
Anlagen installiert und wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene
Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 3/42
DN02166669
Issue 25A
3
Troubleshooting AXC
Id:0900d805807391b2
Confidential
Table of contentsThis document has 42 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1 Troubleshooting the AXC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2 Accessing AXC with web browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 Replacing hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.1 Requirements for installing AXC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.1.1 Installation precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.1.2 Installation restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1.3 Installation tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.1.4 Recommended electrical and optical connectors and cables . . . . . . . . 13
3.2 Adding and replacing IFUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143.3 Replacing AXU or AXC Compact. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.4 Replacing DC-PIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.5 Replacing fan unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4 Using AXC-FB Hopper Manager troubleshooting tools . . . . . . . . . . . . . 20
4.1 Using loopbacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.2 Using forced controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.3 Using internal tests (PRBS). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.4 Using measurement interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5 Local troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.1 Downloading the configuration file fails . . . . . . . . . . . . . . . . . . . . . . . . . 295.2 Configuration file parsing fails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.3 AXC Manager does not start up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5.4 AXU LED remains yellow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
5.5 Local connection to AXC cannot be established . . . . . . . . . . . . . . . . . . 33
5.6 IFU cannot be installed to S-AXC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6 Remote troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
6.1 Remote IP connection to AXC fails . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
6.2 Remote management connection to AXC fails . . . . . . . . . . . . . . . . . . . 37
6.3 AXU or IFU is continuously resetting . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
7 Software update troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
7.1 Configuration is lost after software update. . . . . . . . . . . . . . . . . . . . . . . 39
7.2 Software update fails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
8 AXC unit LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 4/42
4 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805807391b2
Confidential
List of figuresFigure 1 Handling the plug-in units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 2 Forced Controls window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 3 Internal Tests window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 4 Measurements window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 5 Measurement Interface window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 5/42
DN02166669
Issue 25A
5
Troubleshooting AXC
Id:0900d805807391b2
Confidential
List of tablesTable 1 Recommended electrical and optical connectors and cables . . . . . . . . 13
Table 2 LED indications (O/A/F1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 3 IFUE O/A/F2 LED indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 4 IFUE Status of “DC on” LED indications . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 5 Classification of station alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 6/42
6 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805807391b2
Confidential
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 7/42
DN02166669
Issue 25A
7
Troubleshooting AXC Summary of changes
Id:0900d805806f0374
Confidential
Summary of changesChanges between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.
Note that the issue numbering system is changing. For more information, see Guide to
WCDMA RAN operating documentation.
Changes between issues 25A and 25
Editorial modifications have been made.
Changes between issues 25 and 24-1
AXCF unit has been added to sections Requirements for installing AXC and Adding and
replacing IFUs.
Editorial modifcations have been made.
Changes between issues 24-1 and 24-0
Editorial modifications have been made.
Changes between issues 24-0 and 23-0
Instructions for replacing hardware have been moved from Installing and Upgrading the
Hardware of AXC .
Instructions for using AXC-FB Hopper Manager troubleshooting tools have been moved
from Maintaining Nokia FlexiHopper (Plus) and MetroHopper with IFUE .
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 8/42
8 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f0377
Confidential
Troubleshooting the AXC
1 Troubleshooting the AXC
Purpose
Alarms give information on problems in the network element. For more information onreading AXC alarms, see Reading AXC faults in Operating and maintaining AXC . You
can also find a detailed description of the alarms in AXC alarms or under Refer-
ence/Alarms.
During site visits the AXC unit LEDs can be inspected to detect failures. For more infor-
mation, see AXC unit LEDs in AXC product description.
Furthermore, monitoring the performance of AXC can help you to detect problems in the
transmission and physical layer of the network connection. For more information on the
performance monitoring function of AXC, see Monitoring the performance of physical
interfaces, Monitoring ATM performance, Monitoring IMA performance and Inspecting
IP statistics in Operating and maintaining AXC .
For general information on troubleshooting the WCDMA RAN and other 3G network ele-
ments, refer to WCDMA RAN system information set.
Steps
Evaluate how serious the consequences of the problem are.
If the problem has very serious consequences, you may have to call for expert help or
apply an emergency plan immediately.
2 Identify the problem and describe it clearly.
Make an accurate description of the symptoms. You may not be able to solve the
problem yourself. A detailed description of the situation where the symptoms occurred
can help an expert solve the problem.
3 Study the symptoms of the problem.
Analyse and categorise symptoms and list possible causes for the symptoms. Some-
times there can be several related or isolated problems active at the same time. Study
whether the symptoms relate to each other or not. Prioritise symptoms and collect
further facts if needed.
4 Narrow down the possible causes of the problem.
Based on the tests and your knowledge of the system, eliminate symptoms that are not
relevant to the problem you are trying to solve. This way you can focus on symptoms
that are more likely to produce a solution to the problem. Examine what works and what
does not.
5 Carry out corrective actions.
If you have ended up with more than one probable and possible cause for the problem,
change only one thing at a time - otherwise you cannot be sure what change corrected
the failure or the problem.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 9/42
DN02166669
Issue 25A
9
Troubleshooting AXC Troubleshooting the AXC
Id:0900d805806f0377
Confidential
6 Make sure the fault has been corrected.
Further information
For the actual troubleshooting instruction, please refer to the following:
• Downloading the configuration file fails
• Configuration file parsing fails
• AXC Manager does not start up
• AXU LED remains yellow
• Local connection to AXC cannot be established
• IFU cannot be installed to S-AXC
• Remote IP connection to AXC fails
• Remote management connection to AXC fails
• AXU or IFU is continuously resetting
• Configuration is lost after software update
• Software update fails
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 10/42
10 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f037a
Confidential
Accessing AXC with web browser
2 Accessing AXC with web browser
Purpose
This procedure describes how you can use your web browser for reading AXC alarms,retrieving log files, resetting and recovering the AXC, and performing various other oper-
ations.
Steps
Open your web browser.
2 Connect to the AXC.
Enter the local IP address (192.168.255.129) or remote IP address to the Address field
in the web browser.You can now, for example, view AXC alarms, retrieve AXC log files, view the results of
the latest XML parsing and reboot or recover the AXC by clicking on the appropriate link
in the web browser.
Note that recovering the AXC resets it to factory default settings and deletes all config-
urations including the DCN connection. Recover can be performed only locally.
If you reboot the AXC while logged in as a remote user, make sure the remote user
account has Hardware Management change permissions. Click Node → User
Management → View Permissions in AXC Manager.
Further information
If you cannot connect to the AXC, make sure that the LAN settings of your web browser
are correct.
In Internet Explorer, click Tools → Internet Options... and select the Connections
pane. Click LAN Settings... and check that the settings are as follows:
• "Automatically detect settings" cleared
• "Use automatic configuration script" cleared
• "Use a proxy server" selected
• "Bypass proxy server for local addresses" selected
Proxy settings are needed only when connected locally.
In Netscape Navigator, click Edit → Preferences... and select the Advanced/Proxies pane. Make sure that "Direct connection to the Internet" is selected.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 11/42
DN02166669
Issue 25A
11
Troubleshooting AXC Replacing hardware
Id:0900d805806f038c
Confidential
3 Replacing hardware
3.1 Requirements for installing AXC
3.1.1 Installation precautions
Before starting the installation, note the following precautions:
• Familiarise yourself thoroughly with the installation instructions. The instructions areintended for trained installation personnel.
• Plan the installation in advance. Pay special attention to following issues:
• power distribution
• rack grounding
• cabling
• thermal restrictions
Handling the plug-in units
Connect your wrist grounding device into a potential equalisation connector (grounding
point). In S-AXC it is located on the front panel of the fan unit.
!
Backplanes and connectors are fragile. Take great care when installing the plug-in units
in the slots.
!
Protect the cabinet against overvoltage and EMC related damage. Make sure that the
rack is correctly connected to the main ground bar.
!
Optical cables are sensitive. When routing optical cables, do not exert stress on the
optical fibres.
!
Electrostatic discharge (ESD) may damage components in the plug-in units or other
units. Wear an ESD wrist strap or use a corresponding method when handling the units,
and avoid touching the contacts and connector surfaces.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 12/42
12 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f038c
Confidential
Replacing hardware
Figure 1 Handling the plug-in units
Write down the item codes, serial numbers and hardware versions of each plug-in unit
to be installed.
Do not discard the original packages of the units. They are optimal for storing the units,
in case they are replaced.
3.1.2 Installation restrictions
Remember the following restrictions before installing the AXC units:
• the ambient temperature of the installation location must be within the range given
in the technical specifications
• Always install AXU or AXC Compact (AXCC/D) in slot 1.
• A maximum of nine remote power feeds from IFUE are supported.
• Only IFUG, IFUH and AXCF interface units can be installed with AXC Compact
(AXCC and AXCD).
• Only one IFUH or AXCF is supported for each AXC and AXC Compact.
• Always install IFUH or AXCF in the rightmost slot when AXC Compact is used.
In UltraSite WCDMA BTS Optima Compact (Outdoor) use the rightmost slot of the
second row of AXC units.
• IFUH and AXCF cannot be installed in MetroSite WCDMA BTS (WCCM). They can
be installed in MetroSite 50 BTS (WCCF).
Grounding point
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 13/42
DN02166669
Issue 25A
13
Troubleshooting AXC Replacing hardware
Id:0900d805806f038c
Confidential
• Use a crossed cable for interface 1 of the IFUG, interfaces 2-8 are straight.
• Tighten the mounting screws of the AXC units to the maximum torque value of 0.6
Nm.
• The maximum power consumption of one stand-alone AXC cartridge is 500 W.
3.1.3 Installation tools
A standard tool set for electricians and installers is required in the installation of AXC.
Additionally, the following tools are required:
• screwdriver, flat head, M4
• screwdriver, torx head, T10
• screwdriver, torx head, T20
• screwdriver, torx head, T30
• side-cutting pliers
• cable ties
• wrist grounding device
• digital voltage measurement tool
3.1.4 Recommended electrical and optical connectors and cables
The following connectors and cables are recommended for use with AXC, but are not
part of the delivery package.
LC connector (0°)
Single mode fibre, 9/125 μ m, wavelength 1310 nm
Fibre protection acc. set. 2,5M
TQ connector
Telecom cable, 4 x 0.4 solid wire HZ
BT-43 connector
Coaxial cable HZ
TNC connector (straight) for RG214
TNC connector (straight) for RG223
Coaxial cable RG214 HZ (max length 300 m)
Coaxial cable RG223 HZ (max length 140 m)
Table 1 Recommended electrical and optical connectors and cables
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 14/42
14 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f0380
Confidential
3.2 Adding and replacing IFUs
Purpose
The procedures in this section describe how to add and replace units in an operating AXC. There are several options:
• install an IFU to an empty slot
• replace an IFU with an IFU of the same type
• replace an IFU with an IFU of a different type
• remove an IFU and leave the slot empty
When performing these tasks you will have to reconfigure the AXC with AXC Manager
or AXC-FB Hopper Manager. Reconfiguration is not necessary when an IFU is replaced
with an IFU that is of the same type and that contains the same software version.
The removal of an IFU does not interrupt traffic in other IFUs.
Before you start
Go through the precautions, restrictions and instructions for handling units in Require-
ments for installing AXC in Installing AXC .
Switch off the lasers with AXC Manager and disconnect the optical connectors before
removing an IFUC or IFUF. After removing the unit, put the protective caps back on theoptical interfaces.
Switch off the power on the IFUE interfaces before removing the Flexbus cables con-
nected to the outdoor units.
Mixed software releases are not allowed within the same AXC. When replacing a unit
check that the software version of the old and new unit are the same.
If a new unit contains a different software version, unit LED remains yellow until youchange its software. For more information, see Changing AXC software in Expanding
and upgrading AXC .
A faulty IFUH/AXCF unit must be returned to NSN Hardware Services without the SFP
module.
Steps
Installing an IFU to an empty slot
Steps
a Remove the blanking plate.
!
Risk of eye damage caused by invisible laser radiation. Never look directly at the internal
optical fibre connector exit of the transmitter apparatus when it is switched on. In the
event of possible exposure, consult a doctor immediately.
!
The unit is hot. Do not remove the unit until it has cooled down.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 15/42
DN02166669
Issue 25A
15
Troubleshooting AXC
Id:0900d805806f0380
Confidential
b Insert the new unit into the correct slot.
Close the ejectors when the unit is in place. Tighten the unit's locking screws firmly.
Wait until the unit has booted (this can take several minutes).
c Connect the cables to the interfaces.
Route the electrical cables and optical fibres.
d Click View → Refresh → All in AXC Manager.
Check that the new hardware configuration is displayed in the Hardware view. See
Inspecting hardware and modifying identifications in Operating and maintaining
AXC .
e Make all necessary configurations.
2 Replacing an IFU with an IFU of the same type
Steps
a Disconnect all cables from the external interfaces.
b Remove the unit from the slot.
Open the locking screws and ejectors. Pull out the unit holding it by the ejectors.
Store the removed unit in its original package.
c Insert the new unit into the correct slot.
Close the ejectors when the unit is in place. Tighten the unit's locking screws firmly.
d Connect the cables to the interfaces.
Route the electrical cables and optical fibres.
e Click View → Refresh → All after the unit LED becomes green, yellow or red.
If the unit LED remains yellow, it may run on a different software version. See
Changing AXC software in Expanding and upgrading AXC .
If the unit LED turns red, check the physical cable connection.
Check that the new hardware configuration is displayed in the Hardware view. See
Inspecting hardware and modifying identifications Operating and maintaining AXC .
Note that the configurations of the old unit are restored automatically. However,when removing an IFUE, only the configurations in the ATM part are restored. The
configurations of the Flexbus part may be lost and may have to be configured again.
For more information, see Commissioning FlexiHopper (Plus) and MetroHopper
with IFUE .
3 Replacing an IFU with an IFU of different type
Steps
a Disconnect all cables from the external interfaces.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 16/42
16 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f0380
Confidential
b Right-click the slot in the Hardware view and select Uninstall unit.
AXC Manager asks for confirmation, since all configurations of the removed unit are
lost.
Wait until the unit has disappeared from the Hardware view.
c Remove the unit from the slot.
Open the locking screws and ejectors. Pull out the unit holding it by the ejectors.
Store the removed unit in its original package.
d Insert the new unit into the correct slot.
Close the ejectors when the unit is in place. Tighten the unit's locking screws firmly.
Wait until the unit has booted (this can take several minutes).
e Connect the cables to the interfaces.
Route the electrical cables and optical fibres.
f Click View → Refresh → All.
Check that the new hardware configuration is displayed in the Hardware view. See
Inspecting hardware and modifying identifications in Operating and maintaining
AXC .
g Make all necessary configurations.
4 Removing an IFU and leaving the slot empty
Steps
a Disconnect all cables from the external interfaces.
b Right-click the slot in the Hardware view and select Uninstall unit.
AXC Manager asks for confirmation, since all configurations of the removed unit are
lost.
c Remove the unit from the slot.
Open the locking screws and ejectors. Pull out the unit holding it by the ejectors.
Store the removed unit in its original package.
d Install a blanking plate to the slot.
5 Update hardware information in your IM system.
For more information, see Storing item code and serial number for traceability purposes
in Operating and maintaining AXC .
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 17/42
DN02166669
Issue 25A
17
Troubleshooting AXC
Id:0900d805806f0383
Confidential
3.3 Replacing AXU or AXC Compact
Purpose
This procedure describes how to replace the AXU or AXC Compact unit.
Before you start
Go through the precautions, restrictions and instructions for handling units in Require-
ments for installing AXC.
Mixed software releases are not allowed within the AXC. When replacing a unit check
that the software version of the old and new unit are the same. It is recommended that
the new AXU or AXC Compact is either a new unit that has no settings, or if it has been
commissioned before, it has been reset to factory settings.
If you remove the AXU or AXC Compact from a base station and want to install it to a
base station that contains a different type of backplane with a different number of slots,
you first have to reset the AXU or AXC Compact to factory settings.
Steps
Make a backup of the AXC configuration.
Click Node → Export Configuration and select the directory. After exporting the con-
figuration, make sure that the configuration file has been stored in the directory.
2 Switch off the AXC.
3 Disconnect all cables from the AXU or AXC Compact and remove it from the slot.
Open the locking screws and ejectors. Pull out the unit holding it by the ejectors. Store
the removed unit in its original package.
4 Insert the new AXU or AXC Compact.
Close the ejectors when the unit is in place. Tighten the unit's locking screws firmly.
5 Reconnect all cables.
6 Switch on the AXC.
Wait until the AXC has booted and the AXU or AXC Compact LED is green or red.
7 Restore the configuration.
Click Node → Import Configuration and Start Download. After the configuration has
been downloaded, click Activate.
8 Update hardware information in your IM system.
For more information see Storing item code and serial number for traceability purposes.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 18/42
18 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f0386
Confidential
3.4 Replacing DC-PIU
Purpose
This procedure describes how to replace power supply units in the S-AXC subrack.Note that if the DC-PIUs are protected, traffic on the S-AXC is not interrupted.
Steps
Disconnect the DC-PIU from the input voltage.
2 Remove all cables from the external interfaces.
3 Remove the DC-PIU from the slot.
4 Check the jumper settings of the new DC-PIU.
5 Insert the new DC-PIU into the slot.
6 Connect the power cables and the alarm cables to the interfaces.
7 Update hardware information in your IM system.
For more information, see Storing item code and serial number for traceability purposes.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 19/42
DN02166669
Issue 25A
19
Troubleshooting AXC
Id:0900d805806f0389
Confidential
3.5 Replacing fan unit
Purpose
There are two fans in the fan unit of the S-AXC cartridge. If one of them fails, a fan-unitalarm is raised. This procedure describes how to replace a fan unit in the S-AXC
subrack.
Steps
Remove the fan unit.Pull the fan unit out by the front plate slide latches.
2 Check the jumper settings.
Check the jumper settings of the new fan unit against the old unit. Note that in later
hardware versions the jumpers have been replaced by resistors.
3 Insert the new fan unit.
4 Check that the fan failure alarm disappears.
5 Update hardware information in your IM system.
For more information see Storing item code and serial number for traceability purposes.
!
Replace a faulty fan unit as soon as possible. The plug-in units may be damaged if
operated for a long time in the upper ambient temperature range.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 20/42
20 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f039a
Confidential
Using AXC-FB Hopper Manager troubleshooting tools
4 Using AXC-FB Hopper Manager trouble-
shooting tools
4.1 Using loopbacks
Before you start
Setting a Flexbus loop cuts the connection to the outdoor unit until the loop is cancelled
or it expires. This includes all data and management information. Setting an outdoor unit
loop cuts the connection to the outdoor unit until the loop expires.
Before connecting new loops, remove old loops and wait at least one minute. This gives
the system time to be stabilised after the test loops, so that it can start a new test from
a clean point.
Steps
Select Maintenance → Tests → Loopbacks from AXC-FB Hopper Manager menu.
The Loopbacks window opens.
The loopback status can change without you changing it, for example, if the timeout has
been reached. Because of this, the Loopbacks window has its own status bar, which
shows the last time the status of the loopbacks was checked and how long until the next
refresh.
2 Select the loopback position by clicking one of the tabs.
3 Select the loopback to be activated by clicking the loopback button labelled with
a number or arrow corresponding to the loopback.
4 Change timeout control value if necessary.
In the Timeout control field, set the time for the timeout.
5 Activate the loopback by sending the changes to the node.
You can send the changes to the node in two ways:
• on the AXC-FB Hopper Manager menu, select Menu → Send, or
• click the Send button in the Loopbacks window.
Further information
When the control timeout has been reached, the network element is reset to normal
functioning. To reset the network element to its normal state manually, select
Maintenance → Tests → To Normal State from the AXC-FB Hopper Manager menu.
Note that when a control has been set, no other settings take effect until the equipment
is returned to normal state.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 21/42
DN02166669
Issue 25A
21
Troubleshooting AXC Using AXC-FB Hopper Manager troubleshooting tools
Id:0900d805806f039a
Confidential
When using loopbacks in 1IU+2OU protected mode with FlexiHopper (Plus), always
connect loops to both paths of the protected radio hop. This way the complete protected
radio path is tested instead of only one of four possible radio paths.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 22/42
22 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f0391
Confidential
4.2 Using forced controls
Purpose
Units can contain forced controls, which alter the operational state of the networkelement for a user-definable period of time. These controls affect various parameters,
such as cross-connections. They are normally used for testing purposes.
Steps
Select Maintenance → Tests → Forced Controls from AXC-FB Hopper Manager
menu.
The Forced Controls window opens.
Figure 2 Forced Controls window
The controls are divided into tabs depending on the functional entity they apply to, and
a general tab, which applies to the network element.
The control settings can change without you changing them, for example, if the time-out
has been reached. Because of this, the Forced Controls window has its own status bar,
which shows the last time the status of the controls was checked and how long until the
next refresh.
2 Select the IFUE tab.
3 Select forced control values in the drop-down lists.
4 Change control timeout value if necessary.
In the Control timeout field, set the time for the timeout.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 23/42
DN02166669
Issue 25A
23
Troubleshooting AXC
Id:0900d805806f0391
Confidential
5 Refresh the values.
In the Forced Controls window, click the Refresh button.
Alternatively, select Tools → Options → Manager Options and then the Auto Refresh tab. Check the Refresh rate in the dialog box.
6 Activate the selected control by sending the changes to the node.
Click the Send button or select Menu → Send.
Further information
When the control timeout has been reached, the network element is reset to normal
functioning. To reset the network element to its normal state manually, select
Maintenance → Tests → To Normal State from the AXC-FB Hopper Manager menu.
Note that when a control has been set, no other settings take effect until the equipmentis returned to normal state.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 24/42
24 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f0394
Confidential
4.3 Using internal tests (PRBS)
Purpose
PRBS (pseudo-random binary sequence) is a two-level signal that has a repetitivesequence, but a random pattern within the sequence. It is used to test the radio link,
since it has the basic characteristics of a noise, but in terms of parameters that are easily
controlled. One generator in the indoor unit sends a PRBS signal, and the other end of
the radio link detects this signal.
Before you start
Steps
Select Maintenance → Tests → Forced Controls from AXC-FB Hopper Manager
menu.
The Forced Controls window opens. For more information, see Using forced controls.
2 Set Detector Input and Generator Output from the drop-down list
• Select Unit:
• For PRBS2, select 2M interface (way to the 2Mbit plug-in units) or Flexbus 2M
channel (direction to the Flexbus).
• For PRBSF, select the used Flexbus.
• Select Channel:
• If you have selected the 2M interface, then select one 2Mbit interface from oneof the 2Mbit plug-in units.
• If you have selected the Flexbus 2M channel, then select one of the 16 channels
of one Flexbus.
3 In the Forced Controls window, select Polynomial (used PRBS bit pattern) in the
drop-down list.
For more information, see Using forced controls.
4 Reset the counters,
Select Maintenance → Performance → Reset counters from the AXC-FB Hopper
Manager menu.
Select the unit in the Reset Counters dialog box and click the OK button.
5 Click Maintenance → Tests → Internal Tests from the AXC-FB Hopper Manager
menu.
The Internal Tests window opens, and you can select the unit-specific tests to perform.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 25/42
DN02166669
Issue 25A
25
Troubleshooting AXC
Id:0900d805806f0394
Confidential
Figure 3 Internal Tests window
6 In the Test drop-down list, select PRBS mode.
• Timed test: Measurement result and alarm state are displayed only after complete
measurement time has passed.
• Infinite test: Measurement result and alarm state are updated every second.
7 Start the PRBS test.
Click the Send button in the Internal tests window or select Menu → Manager → Send
from the AXC-FB Hopper Manager menu.
8 View the PRBS test results.
Select Maintenance → Performance → Measurements from the AXC-FB Hopper
Manager menu.
The Select Measurements dialog box opens. Select PRBS2 or PRBSF and click OK toopen the Measurements window.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 26/42
26 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f0394
Confidential
Figure 4 Measurements window
If the bit error ratio (BER) value in the Measurements window is higher than 1E-3, thealarm is activated. The alarm is cleared after one complete measurement with BER
value better than 1E-3, or by resetting the counters.
Further information
When the control timeout has been reached, the network element is reset to normal
functioning. To reset the network element to its normal state manually, select
Maintenance → Tests → To Normal State from the AXC-FB Hopper Manager menu.
Note that when a control has been set, no other settings take effect until the equipment
is returned to normal state.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 27/42
DN02166669
Issue 25A
27
Troubleshooting AXC
Id:0900d805806f0397
Confidential
4.4 Using measurement interface
Purpose
The indoor unit can send a signal to its measurement point interface (MP) for analysis.The IFUE measurement point is located on the front panel.
The available 2 Mbit/s G.703 signals are:
• 2M TX data
• 2M TX clock
• BFI 2M RX data (signals in the cross-connection section)
• BFI 2M RX clock
• 2M PRBS (Pseudo-Random Binary Sequence)
• 2M AIS (Alarm Indication Signal)
The available 37 Mbit/s clock signals are:
• Flexbus TX clock
• Flexbus RX clock
In IFUE the measurement point output is 75 Ω G.703.
Steps
Select Maintenance → Tests → Measurement Interface from AXC-FB Hopper
Manager menu.
The Measurement Interface window opens.
Figure 5 Measurement Interface window
2 In the Measurement point connector signal drop-down list, select the signal to be
connected to the measurement point.
The 2 Mbit/s data and clock signals also require you to choose a channel.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 28/42
28 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f0397
Confidential
3 In the Timeout control field, change control timeout value if necessary.
In the Time text box, set the time for the timeout.
4 Activate the signal to the measurement point by sending the changes to the node.
Click the Send button or select Menu → Send from the AXC-FB Hopper Manager
menu.
This sends all modified values to the network element.
5 To refresh the information in the window, click Refresh.
Further information
When the control timeout has been reached, the network element is reset to normal
functioning. To reset the network element to its normal state manually, select
Maintenance → Tests → To Normal State from the AXC-FB Hopper Manager menu.
Note that when a control has been set, no other settings take effect until the equipment
is returned to normal state.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 29/42
DN02166669
Issue 25A
29
Troubleshooting AXC Local troubleshooting
Id:0900d805807391b7
Confidential
5 Local troubleshooting
5.1 Downloading the configuration file fails
Description
Downloading the XML configuration file fails. The configuration file is available on either
an external FTP server or on the LMT. AXC Manager is connected to the AXC locally or
remotely.
Symptoms
• XML file download has failed
Recovery procedures
Check the following in the order they are described.
Check the user permissions
If you are logged in as a remote user, check the configuration file management permis-
sions from Node → User Management → View Permissions in AXC Manager.
Check that username and password are correct
Check that the username and password for the external FTP session are correct. You
can do this by opening an FTP session with the DOS command shell prompt. The
internal FTP server of AXC Manager is activated automatically during software down-
load.
Check that the FTP server is running
If the external FTP server is used, check that the FTP server is running. The internal FTP
server of AXC Manager is activated automatically during software download.
Check that no other FTP servers are running on the LMT
Check that there are no other FTP servers running on the LMT apart from the internal
FTP server of AXC Manager, as this can cause port conflicts. Close any other FTP
servers.
Check that the access rights of the user are set correctly
Check that the access rights for the external FTP server are set correctly.
Check the firewall rules and bandwidth for the external FTP
If the external FTP is used, check that the firewall rules are appropriate. Check also that
the bandwidth of the DCN is sufficient.
Check the path of the configuration file
Check that the path of the configuration file is correct.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 30/42
30 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d8058073dfb8
Confidential
5.2 Configuration file parsing fails
Description
AXC Manager is connected to the AXC locally or remotely. The XML configuration file
has been downloaded and activated successfully and the node has been booted up.
When connecting to the AXC, the configuration is incomplete or completely missing.
Symptoms
• XML file parsing has failed
Recovery procedures
Check the configuration file
Use the information in the parsing log file (AML_PARSING.LOG) to check the objectswhose creation failed in the XML configuration file. See Accessing AXC with web
browser for instructions on how to retrieve the information.
Check the parsing log file for errors and go through the problematic sections of the XML
configuration file carefully. Contact your planning department and ask them to check the
file or provide a new one for this site.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 31/42
DN02166669
Issue 25A
31
Troubleshooting AXC
Id:0900d805806f03a2
Confidential
5.3 AXC Manager does not start up
Description
AXC Manager does not start up from the Start menu (Start → Programs → AXC
Manager ).
Symptoms
• the application does not open
• an error message is displayed
Recovery procedures
Check the following in the order they are described. Try to start AXC Manager after each
recovery action.
Delete all processes called AXCEMStart.exe
Open Task Manager and delete all processes called AXCEMStart.exe.
Check that regional settings are correct
Check that regional settings of the Local Management Tool are as required. Only one of
the following settings is allowed: English (United States, United Kingdom, Ireland),
Finnish or German (Standard).
Reboot the LMT
Restart the Local Management Tool.
Reinstall AXC Manager
Reinstall AXC Manager on the LMT. For more information, see Installing AXC Manager
from NOLS.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 32/42
32 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d8058073dff8
Confidential
5.4 AXU LED remains yellow
Description
The LED of the ATM Cross-connect Unit (AXU) remains yellow when it is installed to
AXC.
The boot time depends on the configuration and can be up to 5 minutes. As long as the
AXU LED is yellow, AXC cannot be operated.
Symptoms
• the AXU LED is yellow
• no connection possible
• the IFU LED is also yellow
Recovery procedures
Check the following in the order they are described.
Check the plug-in units
Make sure that the AXU and the interface units are installed in the correct slots. Check
that they are completely plugged in.
Reset the AXC node
Switch the AXC off and start it again. Wait for a while to see if the AXU LED switches to
green. It is recommended that you try to reset the AXC manually several times.
Delete AXC system configuration information
If the AXU LED stays yellow after several manual resets, it is possible that AXC system
configuration information is corrupted and must be deleted.
Connect to the AXC locally as instructed in Accessing AXC with web browser and click
Recover .
The AXC resets and comes up with factory default settings. Use the configuration back-
up file to restore the configuration of the AXC or re-commission the AXC manually with
AXC Manager.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 33/42
DN02166669
Issue 25A
33
Troubleshooting AXC
Id:0900d805806f03a8
Confidential
5.5 Local connection to AXC cannot be established
Description
Local connection to the AXC cannot be established with AXC Manager (File →
Connect).
Symptoms
• no connection can be established
• a CORBA error occurs
• there are errors during the reading of the IOR file
Recovery procedures
Check the following in the order they are described. Try to connect to the AXC after eachrecovery action.
Check that the LAN cable is of the correct type
Check that you are using a crossed Ethernet cable with RJ-45 connector.
Check also that the Ethernet interface of the LMT PC is configured to 10 Mbit/s half-
duplex.
Check your personal firewall
Make sure that the IP address of the AXC is included in the friend list of your personal
firewall or remove the firewall.
You must also clear "Check Point SecuRemote" check box. In Windows 2000, you canfind it from Settings → Network/Dial-up Connections → Local Area Connection Proper-
ties.
Check that communications between the LMT and AXC works
Check that the communications between the LMT and the AXC works using the ping
command. To do this, open a DOS prompt window and enter the following command:
ping 192.168.255.129.
Check that the IP addresses of the AXC and LMT and make sure that their subnets fit
together.
Check that AXC Manager is compatible with AXC software and hardware
Check that AXC Manager is compatible with the installed AXC hardware and software.
Each AXC software release has to be used with a dedicated AXC Manager.
Check that username and password are correct
Check that the username and password are correct. The default username is "Nemuad-
min" and default password "nemuuser".
Restart AXC Manager
Close and restart AXC Manager.
Reboot the LMT
Restart the Local Management Tool.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 34/42
34 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f03a8
Confidential
Reinstall AXC Manager
Reinstall AXC Manager on the LMT. For more information, see Installing AXC Manager
from NOLS.
Restart the AXC
Restart the AXC.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 35/42
DN02166669
Issue 25A
35
Troubleshooting AXC
Id:0900d8058073920e
Confidential
5.6 IFU cannot be installed to S-AXC
Description
Installation of an interface unit to the Stand-alone AXC is unsuccessful.
Symptoms
• the unit does not boot automatically when installed to the Stand-alone AXC
Recovery procedures
Check for alarm 61202
Check whether the alarm 61202 SW version mismatch is active and update the software
if necessary.
Check the fan unit jumper settings
If the S-AXC fan unit is of the type that has jumpers, check the jumper settings against
Fan unit jumper in Installing AXC . Change the settings if necessary.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 36/42
36 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d8058073dfff
Confidential
Remote troubleshooting
6 Remote troubleshooting
6.1 Remote IP connection to AXC fails
Description
Remote IP connection to AXC is not working correctly.
Symptoms
• no connection can be established
• AXC cannot be pinged
Recovery procedures
Check the following in the order they are described.
Check the active alarms
Check which alarms are active in the network.
Check the IP address
Check that the IP address of the AXC is correct. Try to ping the AXC with the address.
Check the IP address of the LMT.
You can also use the traceroute tool to try to locate the part of the network in which the
problem resides.
Check that the bandwidth is sufficient
Check that the bandwidth reserved within the DCN connection is sufficient. The band-
width must be at least 150 cells/s.
If possible, reduce the amount of CBR traffic over the same line.
Check ATM parameters
Check the following ATM parameters in the RNC and modify them if necessary:
• policing
• Cell Delay Variation Tolerance
• conformance definition
• service category • shaping
Recreate the IP over ATM settings of the RNC
Delete the IP over ATM settings for this AXC in the RNC and recreate them.
Visit the site
Go to the site and continue with local troubleshooting instructions.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 37/42
DN02166669
Issue 25A
37
Troubleshooting AXC
Id:0900d8058073e001
Confidential
6.2 Remote management connection to AXC fails
Description
Remote management connection to AXC is not working correctly.
Symptoms
• AXC can be pinged (if not, see Remote IP connection to AXC fails)
• a CORBA error occurs
• there are errors during the reading of the IOR file
Recovery procedures
Check the following in the order they are described.
Check account information
Check that the username, password and IP address are correct in the Connect dialog
of AXC Manager. The default username is "Nemuadmin" and password "nemuuser".
Restart AXC Manager
Close and restart AXC Manager.
Reset the AXC remotely
Reset the AXC using the web interface.
Continue with local troubleshooting
Go to the site and continue with the local troubleshooting instructions.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 38/42
38 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f03b6
Confidential
6.3 AXU or IFU is continuously resetting
Description
AXU or IFU is continuously resetting.
Symptoms
• AXU or IFU is continuously resetting
• AXC behaves in an unusual way
Recovery procedures
Reboot the AXC
Reboot the AXC manually.
Recreate AXC system configuration information remotely
If AXC behaves in an unusual way, it is possible that AXC system configuration informa-
tion is corrupted and must be re-created. You can do this remotely as follows:
1. Connect to AXC with AXC Manager.
2. Export the current configuration by selecting Node → Export Configuration....
You can also use a back-up of the current configuration if it is available.
3. Import the same configuration by selecting Node → Import Configuration... and
activate it. For detailed instructions, see Modifying AXC configuration with XML con-
figuration file in Integrating and configuring AXC .
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 39/42
DN02166669
Issue 25A
39
Troubleshooting AXC Software update troubleshooting
Id:0900d805806f03c1
Confidential
7 Software update troubleshooting
7.1 Configuration is lost after software update
Description
Configuration is not correctly maintained across the software update of AXC.
Symptoms
• AXC has lost settings
• AXC starts with factory default configuration after the software update
• remote management connection is lost after software update
For more information, see Changing AXC software in Expanding and upgrading AXC .
Recovery procedures
Check the following in the order they are described.
Check whether RNC and other DCN network elements work correctly
If the remote management connection is not working, check carefully and reconfigure
RNC and IP over ATM, for example, before going to the site.
Check the results of the XML download
Go to the site and check the parsing log. For more information, see Configuration file
parsing fails.
If possible correct the XML file and perform an automated commissioning proce-
dure
Upload the AXC configuration in an XML file via AXC Manager. Correct the XML file,
download it to the AXC and activate it. For more information, see Commissioning the
AXC with XML configuration file in Commissioning AXC .
Perform an automated commissioning procedure with a configuration back-up
XML file
Download the back-up XML file and activate it. For more information, see Commission-
ing the AXC with XML configuration file in Commissioning AXC .
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 40/42
40 DN02166669
Issue 25A
Troubleshooting AXC
Id:0900d805806f03be
Confidential
7.2 Software update fails
Description
Updating the software of the AXC is unsuccessful.
Symptoms
• download or activation of the software has failed. You can check the success of the
activation from the Node Software window. For more information, see Changing
AXC software in Expanding and upgrading AXC .
Recovery procedures
Check the following in the order they are described.
Check the software update instructions
Check the software update instructions that are included in the Release Binder. The
instructions contain the latest information on how to update the AXC software.
Check the user permissions
If you are logged in as a remote user, check the software management permissions from
Node → User Management → View Permissions in AXC Manager.
Check that the node runs the software of the previous release
Check that the node that you are updating runs the software of the previous release. You
can check the software version in the AXC by selecting Node → Software.
Check that username and password are correct
Check that the username and password for the external FTP session are correct. The
integrated FTP server is activated automatically during software download.
Check that the FTP server is running
If an external FTP server is used, check that the FTP server is running. The integrated
FTP server is activated automatically during software download.
Check that no other FTP servers are running on the LMT
Check that there is no other FTP server running on the LMT apart from the integrated
FTP server, as this can cause a port conflict. Close all other FTP servers.
Check that the access rights of the users are set correctly
Check that the access rights for the external FTP server are set correctly. See relevant
documentation for more information.
Check the path of the software package in the Target Build Descriptor
If an external FTP server is used the path specified in the Target Build Descriptor should
be relative to the root directory specified for the FTP server. This is not required for the
integrated FTP server.
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 41/42
DN02166669
Issue 25A
41
Troubleshooting AXC AXC unit LEDs
Id:0900d805806efeb6
Confidential
8 AXC unit LEDs
Front panel LEDs
Each unit in the AXC has a 3-colour status LED located on the front panel. These indi-cators display the current state of the equipment.
IFUE LEDs
Interface unit IFUE has two 3-colour status LEDs on the front panel indicating the oper-
ational status of the unit: O/A/F1 and O/A/F2 (O/A/F signifies Operation/Alarm/Fail). The
O/A/F1 LED indicates the operational status of the ATM part and the O/A/F2 LED indi-
cates the operational status of the Flexbus part of the IFUE. In addition, each of the three
Flexbus interfaces has a status LED of its own (DC on).
• O/A/F1 (ATM part)
• O/A/F2 (Flexbus part)
• DC on (Flexbus 1)
• DC on (Flexbus 2)
• DC on (Flexbus 3)
The following table shows the indications of the O/A/F2 multi-colour LED for the Flexbus
part.
The following table shows shows the indications of the DC on Flexbus LEDs.
Colour Explanation
Stable red Major or critical alarm
Blinking red Minor alarm
Stable yellow Unit starting up
Stable green Normal operation, power on
Blinking green Software download from LMT or network
during operation
Table 2 LED indications (O/A/F1)
Colour Status
Green The unit functions well, no alarms.
Yellow Alarms with low priority occur, e.g. “the
node clock is not set”
Red Some errors occur, e.g. “LOS of FB1” or
“2M interface 3: Buffer overflow”
Table 3 IFUE O/A/F2 LED indications
Indication Status
Off Normal status, no remote power feeding.
Table 4 IFUE Status of “DC on” LED indications
8/16/2019 Axc Troubleshooting
http://slidepdf.com/reader/full/axc-troubleshooting 42/42
Troubleshooting AXC AXC unit LEDs
DC-PIU LEDs
The classification of the station alarms of the DC-PIU is described in the table below.
When there are no incoming station alarms the DC-PIU is not lit.
Blinking Try to find an Outdoor Unit (OU), remote
power feeding is temporarily on.
On OU found and remote power feeding is on.
Severity Class Colour
Critical, major A Red
Minor B Yellow
Reminder (disabled A or B alarm) D Green
Table 5 Classification of station alarms
Indication Status
Table 4 IFUE Status of “DC on” LED indications (Cont.)