B O N N E V I L L E P O W E R A D M I N I S T R A T I O N
Residential LED Recessed Down light Fixtures
RTF
January 4, 2011
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N
2
Background
RTF deemed savings for specialty bulbs at April 2010 meeting.
LED Downlight measure was included:
Analysis was completed with same inputs and assumptions as reflector (specialty) bulbs
Lamp Type Direct Install Retail Direct Install RetailLED Downlight- Inc_base 0.9 1.1 34.1 35.2
TRC B/C Ratio Annual kWh Savings
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N
3
Residential LED Down Light Fixtures
New LED recessed down light fixtures• Recommend updating
– Hours of use from 1.9 hours/day to ~3.0 hours/day Specific hours of use by room type instead of average for
applicable uses
– Efficacy requirements – Increase to 50 Lumens/watt
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N
4
Updated Inputs – Hours of Use
RTF approved Hours of Use
Lamp TypeDaily
Hours of Use
Source
LED Downlight- Inc_base 1.9
The Cadmus Group, Inc. "Residential Retrofit High Impact Measure Evaluation Report", prepared for the California Public Utilities Commission, February 2010
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N
RTF Hours of Use by Room TypeHours of Use (hours/day), by Room Type
Room Type DOE 2002 KEMA 2005 EMI 2007 Average
Dining room 2.5 2.5 3.0 2.7
Kitchen 3.0 3.5 3.9 3.5
Bathroom 1.8 1.5 1.7 1.7
Living Room 2.5 3.3 3.1 3.0
Exterior 2.1 3.1 3.4 2.9
Bedroom 1.1 1.6 1.3 1.3
Family/Den 1.8 2.5 2.5 2.3
Hallway/Foyer /Stairs 1.5 1.6 1.6 1.6
Garage 1.5 2.5 2.5 2.2
Office 1.8 1.8
Basement/Utility Room
Laundry 1.2 1.3 1.3
Closet
Other 1.9 1.9 1.9
5
Average based on all room types
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N
RTF Reflectors by Room Type
Analysis of reflectors
Not appropriate for downlight application
Likely only installed in dining room, kitchen, and living room• Need to be
dimmable
6
(from KEMA 2010, CA Statewide for CPUC)
Locations of Bulbs ReflectorBathroom 9%Bedroom 6%
Kitchen 21%Exterior 20%
Living Room 9%Hallway/Foyer /Stairs 14%
Dining room 3%Basement/Utility Room na
Family/Den 7%Laundry na
Other 2%Closet na
Garage 1%Office 6%Total 98%
Percentages by lamp type may not add to 100% due to rounding
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N
Calculating Daily Hours of Use
For lamp types not metered in CA study• Use location* (room type) and hours of use by
location** to determine lamp hours of use
*The Cadmus Group, Inc. "Residential Retrofit High Impact Measure Evaluation Report", prepared for the California Public Utilities Commission, February 2010
**Navigant Consulting, "U.S. Lighting Market Characterization, Volume I: National Lighting Inventory and Energy Consumption Estimate Final Report", Table 5-9, p 40, Prepared for U.S.
Department of Energy Office of Energy Efficiency and Renewable Energy, 2002
**KEMA, Inc.,”CFL Metering Study” for Pacific Gas & Electric Company, Southern California Edison Company, San Diego Gas & Electric Company, 2005.
**Energy Market Innovations, Inc., "Puget Sound Area Residential Compact Fluorescent Lighting Market Saturation Study", November 2007
RoomType
RoomTypeRoomTypelamp Prevalence*HOUHOU
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N
Updated Hours of Use Calculation
Reweight prevalence by applicable room types
3.35 hours weighted average• Rounded to 3 for analysis
Room TypeHours of
UseReflector
Prevalence
Re-weighted for downlight
applicationsDownlight
Hours of Use
Kitchen 3.5 21% 64%Living Room 3.3 9% 27%Dining Room 2.5 3% 9%
0.33 3.35
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N
9
Savings and Cost Effectiveness
3 hours 6th Plan ProCost
• All other inputs consistent with approved analysis
Increase of about 20 kWh per bulb
Lamp Type Direct Install Retail Direct Install RetailLED Downlight- Inc_base 1.5 1.6 53.9 55.6
TRC B/C Ratio Annual kWh Savings
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N
10
Proposal
Revise deemed savings for Approved LED Recessed Down Light fixtures for use in residential applications.
Recommended Measure Specifications:• Must be Energy Star rated LED fixtures