1
Condition Monitoring for Power Plant Industry Vibration based Condition Monitoring Dynamics Laboratory Jalan Taman Sari 126 Bandung Telp.: 022-2512970, 022-2534144 Fax.:022-2512970 Optical Sensor Signal Conditioning Online Monitoring 3 Input Channel (for Velocity Transducer) 6 Output Channel (3 in mV and 3 in 4-20mA) RMS Display (Average, Maximum, Minimum) Date and Time Display Data is saved every hour up to 30 days Latest version up to 170 days (6 month) Data are download with RS232 Connector Features : 12 Input Channel (for Velocity Transducer) Vibration level, waveform, and spectrum displays Vibration level, waveform, and spectrum can be downloaded (USB connector) Trending vibration level Send SMS for alarm reporting and inquiry Features : Online Monitoring Output 4 – 20 mA RPM Display Key Phasor Signal for Balancing, Synchronous Time Averaging, and Phase Measurement Features : Accelerometer 3-Axis and Temperature 4 in 1 3-Axis (X,Y,Z) and Temperature Sensor Dynamic Range : ±3G. Frequency Range : 10 – 1000 Hz Max. Operating Temperature : 120°C Features :

Backup of Poster

Embed Size (px)

DESCRIPTION

Poster Instrument

Citation preview

Condition Monitoring for Power Plant IndustryVibration based Condition Monitoring

Dynamics LaboratoryJalan Taman Sari 126 Bandung

Telp.: 022-2512970, 022-2534144 Fax.:022-2512970

Optical Sensor Signal Conditioning

Online Monitoring

• 3 Input Channel (for Velocity Transducer)

• 6 Output Channel (3 in mV and 3 in 4-20mA)

• RMS Display (Average, Maximum, Minimum)

• Date and Time Display

• Data is saved every hour up to 30 days

Latest version up to 170 days (6 month)

• Data are download with RS232 Connector

Features :• 12 Input Channel (for Velocity Transducer)

• Vibration level, waveform, and spectrum displays

• Vibration level, waveform, and spectrum can be

downloaded (USB connector)

• Trending vibration level

• Send SMS for alarm reporting and inquiry

Features :

Online Monitoring

Output

4 – 20 mA

• RPM Display

• Key Phasor Signal for

Balancing, Synchronous

Time Averaging, and Phase

Measurement

Features :Accelerometer 3-Axis and Temperature

• 4 in 1

3-Axis (X,Y,Z) and Temperature Sensor

• Dynamic Range : ±3G.

• Frequency Range : 10– 1000 Hz

• Max. Operating Temperature : 120°C

Features :