12
Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to know abundance? Allows determination of biomass pool size. Provides crude estimate of element fluxes. Helps to characterize dynamics of ecosystem. Challenges with natural samples Low concentrations Methods Dry and weigh (not with natural samples). Plate (or viable) count (Today). Direct count. (Thursday).

Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to

Embed Size (px)

Citation preview

Page 1: Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to

Bacterial Abundance

Objective

• Measure bacterial numbers and mass per unit volume.

• Note, we are not concerned with identification here.

Why do we want to know abundance?

• Allows determination of biomass pool size.

• Provides crude estimate of element fluxes.

• Helps to characterize dynamics of ecosystem.

Challenges with natural samples

• Low concentrations

Methods

• Dry and weigh (not with natural samples).

• Plate (or viable) count (Today).

• Direct count. (Thursday).

Page 2: Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to

Why do we want to measure bacterial concentration?

Estimate bacterial pool size

• Ocean: 109 cells l-1

20 fg C cell-1 (20 10-15 g C cell-1)

1.37 1021 l oceans-1

Crude estimate of element fluxes (x: bacterial biomass)

• Growth rate: G = x; : specific growth rate

Uptake rate: U = x/; : growth efficiency

Typical: = 1 d-1; = 0.2

Ecosystem dynamics

27 Gt C oceans-1

E.g., Bacterial concentration is 100 cells ml-1 or 100 fg C ml-1

BU G

CO2

B

Time

Con

c.

R

Page 3: Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to

How is bacterial concentration measured?

Laboratory cultures

• Measure optical density and cell dry weight

Problems

• High cell densities required.• Must be only cells (i.e., no debris or detritus)• High predator abundance would also skew results.Technique does not work in the field!

Dilution Plates

• Grow single cells on Petri plate until colonies are visible, then count colonies.

• Must use serial dilution so that colonies are in countable range.

• This method has a major problem. What is it? (Akin to growing fish in chicken soup)

Direct Counts

• Use microscope to directly count bacteria.

Problem: Bacteria in natural environments are very small and difficult to see and distinguish from detritus using standard light microscopy.

OD

Cel

l den

sity

Page 4: Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to

Dilution Plates1 ml 1 ml 1 ml 1 ml 1 ml 1 ml

10-1 10-2 10-3 10-4 10-5 10-6

Statistically relevant colony density: 30 - 300

Technique largely used for isolation or water testing, such as coliform test.

9 ml

Page 5: Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to

Dilution Plate Calculations

N: Number of colonies on plate

VS: Volume pipetted onto Petri plate.

D: Dilution factor for test tube plated out.

: Concentration of cells in original sample (cells ml-1)

D1

VN

ρS

Example:

N: 33

VS: 100 l

D: 10-4

164- mlcells103.3

101

0.133

ρ

Page 6: Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to

Fecal Coliform Counts

The abundance of fecal coliform bacteria are used as an indicator of fecal contamination of both drinking water and recreational water (i.e., swimming, shellfishing).

Fecal coliform bacteria inhabit the intestinal tracks of animals. While the indicator bacteria are typically not pathogens, they indicate that the water has become contaminated with fecal material, either by human or other animals.

Although it would be better to assay for pathogens directly (such as hepatitis), it is too difficult to culture these organism quickly and reliably.

Basic method:• Aseptically collect and filter water onto sterile filter.• Place filter on sterile pad that contains medium for the culturing of fecal coliform

bacteria (contains eosin-methylene blue dye)• Incubate filter at 37ºC (or higher)• Count colonies to determine colonies/100 ml water

EPA requirements (cfu/100ml):• Drinking water: None• Shell fishing: 14• Swimming 200

Page 7: Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to

Some Drinking Water Pathogens

Viruses:•Hepatitis

Bacteria:•Cholera (Vibrio cholera)•typhoid fever (Salmonella typhi) •Fecal bacteria (often Escherichia coli)

Protists:•Cryptosporidia •Giardia

Page 8: Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to

Direct Bacterial Counts

Challenges with Direct Count Method

• Natural samples contain low concentrations of bacteria (106 cells ml-1)

Must concentrate bacteria

• Bacteria are small (0.2 - 1 m) so difficult to see and differentiate from

detritus using microscope with normal or phase contrast lighting

techniques.

Must stain with fluorescent dye and use epifluorescence

microscopy.

Procedure outline

• Incubate water sample with fluorescent dye.

• Concentrate sample onto 0.2 m filter.

• Place filter on slide, and count bacteria in grid

• Calculate bacterial numbers.

Page 9: Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to

Epifluorescence Microscopy

Fluorescence

•Compound is “excited” at a particular wavelength of light (usually in the UV)

•Compound then emits light at a different, lower, wavelength.

•Advantage: contrast is extremely high, which allows detection of weak light.

Dyes used

•Acridine orange (AO)

•DAPI (4’6-diamidino-2-phenylindole)

Mechanisms

•AO fluoresces when bound to DNA or RNA. Cells appear orange.

•DAPI fluoresces when bound to DNA and is more specific. Cells appear blue.

Page 10: Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to

Epifluorescence Details

UV Light source

Excitation filter

Beam splitter, Emission filter

Objective

Sample

Eyepiece

Page 11: Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to

Slide Preparation for DAPI

Cover slip

Drop of immersion oil

Drop of immersion oil

Microscope Slide

Filter, bacteria side up!

Notes:• Place filter so that bacteria are on the top side.• Use small drops of immersion oil• Cover slips stick together. If you have more than one, you will not be

able to focus well.• Label slide.

Drop of immersion oil

Page 12: Bacterial Abundance Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here. Why do we want to

Cell Density Calculations

Known or measured

• Volume of sample filtered: VS

• Area of filter occupied by sample: AF

• Area of grid in field of view: AG

• Average number of cells grid-1: N

Cell Concentration

• Cell Conc:

RF

AF = RF2

S

G

F

V

NAA

ρ

AG

Whole filterFilter wetted by sample

What is the main assumption in this calculation?