SERVICE MANUAL
MODEL : SM-100
EDITION
Month Y ear 1st December 2004 2nd March 2006 3rd February 2007 4th February 2009
SHANGHAI TERAOKA ELECTRONIC CO., LTDTECHNICAL SUPPORT DEPARTMENT
1rd Floor of 2nd Building, Jia Yuan Business Center,51# Long Wu Road, Shanghai China 200232.
TEL : +86-21-6408-5151 FAX : +86-21-6408-3468EMAIL ADDRESS :[email protected]
Table of Content
1. GENERAL INFORMATION ........................................................................1
1.1 Overall View ............................................................................................................................. ...................... 1
1.2 Display Panel.................................................................................................................................................. 3
1.3 Key Panel........................................................................................................................................................... 3
1.4 Thermal Printer Head ............................................................................................................................ 9
1.5 Features ............................................................................................................................. ................................10
1.6 Specification..................................................................................................................................................11
1.7 Label Type ............................................................................................................................. .........................12
2. Initial Setup ..................................................................................................................13
2.1 Setup ............................................................................................................................. .......................................13
2.2 Location of Switches and Connectors.................................................................................. 15
2.3 Memory Initialisation............................................................................................................................ 15
2.4 Default Specification Setting ......................................................................................................... 16
3. Calibration.....................................................................................................................18
3.1 Calibration Operation .......................................................................................................................... 18
3.2 Exit Calibration..........................................................................................................................................19
4. Software Setting ....................................................................................................... 20
4.1 Software Version Upgrade .............................................................................................................. 20
4.2 Specification Setting ............................................................................................................................. .32
5. Adjustment................................................................................................................... 34
5.1. Peer Sensor Voltage and Label Sensor Sensitivity Adjustment....................34
5.2. Adjustment of Printing Position............................................................................................... 37
5.3. Voltage Checkpoint ............................................................................................................................. .38
6. Interface ......................................................................................................................... 39
6.1. PC Interface.................................................................................................................................................39
6.2. Scale Ethernet Address ..................................................................................................................... 40
6.3. Scale IP Address ............................................................................................................................. .........41
6.4. Connection Method ............................................................................................................................ .42
6.5. Wire Configuration ............................................................................................................................. ..44
7. Miscellaneous ............................................................................................................ 46
7.1. Mode Change ............................................................................................................................. ................46
7.2. Span Switch Status.................................................................................................................................46
7.3. Clear All PLU Data...............................................................................................................................46
7.4. Thermal Head Usage........................................................................................................................... 47
7.5. IP ADDRESS ............................................................................................................................. ...............47
7.6. SERVER IP ADDRESS.................................................................................................................. 47
7.7. SUBNET MASK ............................................................................................................................. .......47
7.8. MAC ADDRESS....................................................................................................................................48
7.9. SERIAL NO ............................................................................................................................. ..................48
8.0. ASCII CHARACTER........................................................................................................................ 49
8. Appendix ...........................................................................................................................
A. SpecificationList_V200
B. FlexibleL Barcode Setting Guide
C. Traceability Setting Guide
D. Nutrition Setting Guide
E. PC-FL1 Operation Guide
F. Circuit
9. Error Message..........................................................................
SM 100 GENERAL
1
1. GENERAL
1.1 OVERALL VIEW
Bench Type
Pole Type
Elevated Type
2
SM 100 GENERAL
Bench-CS Type
Pole-CS Type
Hand Type
3
SM 100 GENERAL
1.2 DISPLAY PANEL
25 digits × 19 segments TN type LCD
32 × 202 full dot Matrix Green LCD
1.3 KEY PANEL
Preset Keys Type ------ B/P32 Preset keys:
40Preset Keys:
4
SM 100 GENERAL
56 Preset Keys Type ------ PCS(New), PCS+ (New)
74 Preset Keys Type ------ EV, PCS(Old)
76 Preset Keys Type (Hanging)
5
C
SM 100 GENERAL
ON/OFF KEY
PRESET KEY
P1 ~ P40 (B/P) P1 ~ P74 (EV) P1~P32(BCS) P1~P56(PCS) P1~P76(H)NUMERIC KEYS
Turn display "ON" or "OFF".
Set up or call either unit price and tare value.
0 ~ 9 Enter numeric data.
TARE KEY
Set or Clear Tare value.
Select "NO" in S and Z Mode.
Item test print in S Mode.
CLEAR KEY
For Back space or Clear numeric value.
Select "YES" in S and Z Mode.
RE-ZERO KEY
PREPACK KEY
Reset weight to ZERO.
AUTO Switch Manual mode and Pre-pack mode alternatively.
(The mode status will be indicated in the P and M indicator.)▪P - PRE-PACK MODE ▪ M - MANUAL MODE
CHANGE KEY
Calculate the Changed Amount.
Escape the Programming screen without saving data in S Mode.
7
MULTIPLLE KEY
Register the number of Non-Weight products.
X Select programming item such as PLU data, Shop Name in S Mode.
Select Report Type in X Mode.
Select Data Transaction Type in Z Mode.
CLERK KEY
V1~V4 Accumulate the Total Price.
VOID KEY
− Correct the sales data.
PLU KEY
PLU Call up PLU data in R Mode.
Store the programmed data in S Mode.
FEED KEY
PRINT KEY
Feed Label or Receipt paper
Print out Label or Receipt.
Note: BCS or PCS stands for the scale with cassette.
MODE SELECT KEY
Five Modes can be selected using this key.
• Indicator R - REGISTRATION MODE (All the sales transactions are
performed.)
• Indicator X - CHECK MODE (Printing out and sales report.)
• Indicator S - PROGRAM MODE (Programming preset data, such as products, data, shop name, etc.)
• Indicator Z - TOTAL MODE (Clear sales data stored.)
• Indicator X (Blink) - Password Setting Mode (Set PASS WORD for X, S, Z mode, set PASSWORD for PASSWORD MODE when all indicators(R, X, S, Z) blink)
Decrease/Increase Specification Count key
︽,︾ Decrease/Increase Only used when Setting SPEC 141 & 142
<<,>> Select parameter data such as SPEC data. Move cursor left or right.
1.4 Thermal Printer Head
Max Printing With: 56mm
9
1.5 FEATURES
Digital printing scale consists of electronic cash registers function and label printing function.
High-speed, high reliability thermal head printer.
Easy paper handing achieved special designed mechanism.
Built-in clock automatically updates data and time.
Quick response to weight changes.
Capacity and Resoultion
Capacity 3kg 6kg 12kg 15kg 30kg 60kg
Resolution 1/3000
1/3000S,
1/3000M,
1/6000S
1/3000
1/3000S,
1/3000M,
1/7500S
1/3000S,
1/3000M,
1/6000S
1/3000
Capacity 3lb 6lb 12lb 15lb 30lb 60lb
Resolution
1/3000S,
1/3000M
1/6000S
1/3000
1/3000S,
1/3000M,
1/7500S
1/3000S,
1/3000M,
1/6000S
1/3000S,
1/3000M,
1/6000S
1/3000S,
1/3000M,
1/6000S
Internal count: 1/90000.
Calibrating by software.
Customer and operator display (optional customer pole display).SM-100:
25 digits x 19 segments TN type LCD with back-light for numeric digit and character display.
SM-100+:
32 x 202 full dot Martix Green LCD display.
membrane keys
a. ON/OFF key
b. 10 Numeric keys, to key in numeric data.
c. Preset keys, to preset PLU or function into the key.
d. 16 Operational keys, to perform various functional operations.
18 data files, Department, Main Group, PLU, etc.
Various reports, PLU daily report, Sales daily report,24 hours daily report, etc.
Ethernet function.
Optional wireless Ethernet bridge.
RS232C interface for data communicate and barcode scanner connection.
Optional cash drawer.
Compact housing.
SM 100 GENERAL
10
1.6 SPECIFICATION
1.6.1 DisplaySM-100:25 digits × 19 segment TN type LCD with back-light for numeric digit and character display.
Tare weight display : 4 digits.
Weight display : 5 digits.
Unit price display : 6 digits.
Total price display : 7 digits.
SM-100+:
32 x 202 full dot Martix Green LCD display.
Tare weight display : 4 digits.
Weight display : 5 digits.
Unit price display : 6 digits.
Total price display : 7 digits.
1.6.2 Operating Conditions
Power Source : AC 110V,220V(+10%,-15%), 50~60Hz.
Operating Temperature : -10 °C ~ +40 °C.
Operating Humidity : 15% ~ 85% RH.
Power Consumption : 70 W.
1.6.3 Dimensions
Platter size
Bench, Pole and Elevated : 386(W) x 270(D) mm.
Bench-CS and Pole-CS : 359(W) x 277(D) mm.
Hanging : 274(d) x 35(h) mm.
Overall size
a) Bench : 386(W) x 415(D) x 127(H) mm.
b) Pole : 386(W) x 478(D) x 480(H) mm.
c) Elevated : 386(W) x 416(D) x 550(H) mm.
d) Bench-CS : 380(W) x 360(D) x 162(H) mm.
e) Pole-CS : 380(W) x 380(D) x 509(H) mm.
f) Hand : 340(W) x 310(D) x 544(H) mm.
SM 100 GENERAL
11
1.7 LABEL TYPE
The label diameter range is from 40 to 105 mm.
N o te : Labels must be winding outwards (on top backing paper) and not inwards (under backing paper) within the core (see diagram above). If labels are wound wrongly, printing problem may result. We do not recommend the use of varnish labels.
Label Type Dimension (mm)T1 28 X 56T2 31 X 56T3 34 X 56T4 40 X 56T5 43 X 56T6 46 X 56T7 49 X 56T8 55 X 56T9 37 X 56T10 40 X 56T11 43 X 56T12 49 X 56
S 28 X 37A 46 X 37B 46 X 37C 62 X 37
F1 – F99 Free Format
SM 100 INITIAL SETUP
2. INITIAL SETUP
13
2.1 SETUP
¾ Indication of Assemble
SM 100
¾ Bubble Adjustment
INITIAL SETUP
14
Bubble
Place the scale on the flat surface and adjust the four legs until the bubble on the level is in the centre as shown above.
SM 100
2.2 LOCATION OF SWITCHES AND CONNECTORS
INITIAL SETUP
15
PowerSwitch
FuseHolder
Cash Drawer Port
RS232 Port
Ethernet Port
Span Switch
2.3 MEMORY INITIALISATION
To clear all memory.
OPERATIONDISPLAY
REMARKPT kg $/kg $
Z1.0 RESET SALES DAILYZ mode.
Lamp Z turns on.
[Rezero]+[2][3][0] CLEAR PLU FILE PLU file.
[︾] CLEAR VENDER DATA Vender transaction data.
[︾] CLEAR REPORT FILES Report files.
[︾] CLEAR MEMORY DATA All files in memory.
[*] CLEAR MEMORY Y-C N-T [C] to clear file data,[T] to quit.
[C] or [T] Z1.0 RESET SALES DAILY Return to Z mode.
SM 100 INITIAL SETUP
2.4 DEFAULT SPECIFICATION SETTING
Default SPEC setting of individual country.(Please turn on the span switch before proceed this process.)¾ Country Set
OPERATIONDISPLAY
REMARKPT kg $/kg $Z1.0 RESET SALES DAILY Z mode.Lamp Z turns on.
[Rezero]+[8][8][2][2] SPEC 2-STD COUNTRY Set country setting.
[>>] SPEC 3-CN COUNTRY[>>],[<<] or [X] to select country.[*]
to update country setting.
[*] LOAD DEFAULT SPEC Y-C N-T[C] to load default SPEC setting,[T]
to skip.
[C] SCALE TYPE → POLE Set scale type.
[X] SCALE TYPE → BENCH[X],[-] to select type,[*] to update
type setting.
[*] SCALE CAP. → 3KG Set scale capacity.
[X] SCALE CAP. → 6KG[X],[ - ] to select capacity,[*] to
update capacity setting.
[*] SCALE RES. → 1/3000S Set resolution.
[X] SCALE RES. → 1/3000M[X],[ - ] to select resolution,[*] to
update resolution setting.
[*] CLEAR MEMORY Y-C N-T [C] to clear memory,[T] to skip.
[C] Z1.0 RESET SALES DAILY Return to Z mode.
Note 1: For the first using of SM-100,Please take this operation for initialization.Note 2: Enter a number that represent a country in the country list (refer to the table below) to
initialise and country set.
17
SM 100 INITIAL SETUP
COUNTRY LIST
No. Country Code Country No. Country Code Country0 AA Japan 41 SA Saudi Arabs1 U1 U.S.A. 42 IC Iceland2 STD Standard 43 IE Indonesia3 CN China 44 CB Cuba4 HK Hong Kong 45 KY Kenya5 TW Taiwan 46 IR Israel6 EX Export 47 VY Slovenia7 KE Korea 48 MS Malaysia8 AR Australia And New Zealand 49 SN Spain9 SF South Africa 50 VZ Venezuela
10 CS Cyprus 51 CO Croatia11 GC Greece 52 MA Macedonian12 TU Turkey 53 FR France13 CV Czech Republic 54 WG Germany14 HG Hungary 55 BL Bulgaria15 PL Poland 56 BW Botswans16 UR Russia 57 CP Comores17 AS Austria 58 LS Lesotho18 DM Denmark 59 MU Mauritius19 FL Finland 60 MW Malawi20 NW Norway 61 MZ Mozambique21 SD Sweden 62 NM Namibia22 PG Portugal 63 RE Reunion23 UK United Kingdom 64 SH Seychelles24 IL Ireland (Kg) 65 SW Swaziland25 IL (LB) Ireland (Lb) 66 WZ Zimbabwe26 CA Canada (Kg) 67 ZW Zambia27 CA (LB) Canada (Lb) 68 AE U.A.E28 AG Argentina 69 TT Trinidad and Tobago29 MX Mexico 70 UD Uganda30 BZ Brazil 71 LV Latvia31 CE Chile 72 CVS Slovakia32 EA Egypt 73 SK Sri Lanka33 JD Jordan 74 SV Slovenia34 LN Lebanon 75 UA Ukraine35 IRN Iran 76 KZ Kazakhstan36 CR Canary Islands 77 IT Italy37 TL Thailand 78 SZ Switzerland38 EC European Community 79 ID India39 NL Netherlands 80 CD New Caledonia40 BG Belgium
SM100 CALIBRATION
18
3. CALIBRATION
Prior to Calibration, please refer that the specification indicating weight capacity, minimum
graduation, and load cell sensitivity are correctly set.
Caution:
z It can only work when SPAN SWITCH is on (ENABLE).
Before Calibrating, please enter Z mode.
3.1 CALIBRATION OPERATION
OPERATIONDISPLAY
REMARKPT kg $/kg $
Press SPAN SWITCH Z1.0 RESET SALES DAILYSPAN SWITCH is on
(ENABLE).
[Rezero]+[8][7][1][5] CAL 00Enter [8][7][1][5] while
depressing [Rezero].
Ensure no weight on
platter,[*]------
Calibrating zero point.
After storing the zero
Point ‘IR’ countCAL SP
Put full capacity weight
on platter.[*]------
Calibrating Span.
After calibration Z1.0 RESET SALES DAILYGo back to Z mode. Lamp Z
always light.
19
SM100 CALIBRATION
3.2 EXIT CALIBRATION
OPERATIONDISPLAY
REMARKPT kg $/kg $
Press SPAN SWITCH Z1.0 RESET SALES DAILYSPAN SWITCH is
on(ENABLE).
[Rezero]+[8][7][1][5] CAL 00Enter [8][7][1][5] while
depressing [Rezero].
[T] Z1.0 RESET SALES DAILYEscape to Z mode. Lamp Z
always light
[Rezero]+[8][7][1][5]
[*]
CAL 00
------
The ‘IR’ count will be taken as
the zero point ‘IR’ count.
After storing the zero
Point ‘IR’ countCAL SP
Calibrating Span.
[T] Z1.0 RESET SALES DAILYEscape to Z mode. Lamp Z
always light.
SM 100 SOFTWARE SETTING
20
4 SOFTWARE SETTING
4.1 SOFTWARE VERSION UPGRADE
Update Method IntroductionSM-100 use flash RAM instead of EPROM for the main program storage of the scale.Before the boot program Version 1.10, we just have one method to update the scale’s software: PC to scale via RS232 interface.After the boot program Version 1.10 (including V1.10), we add a new method to update the scale’s software: update the scale by ethernet. So you can choose either method between these two ones to update your scale.Now we will set two parts to introduce the steps of these two updating methods.
Update Steps IntroductionI. Ethernet Update Method
1. Cable & ConnectionThere are also two ways to connect the PC and the scale in updating the scale by ethernet.1) PC to Scale
Crossing Twisted Cable
PC Sm-100
2) Connect by Hub
Normal NormalTwisted Cable Twisted Cable
PC HUB Sm-100
T568B line series1 Orange & White2 Orange3 Green &White4 Blue5 Blue & White6 Green7 Brown & White8 Brown
These two twisted cable obey the EIT/TIA 568 standard.
T568A line series1 Green &White2 Green3 Orange & White4 Blue5 Blue & White6 Orange7 Brown & White8 Brown
crossing twisted cable: one end with T568A line series, another with T568B line series
normal twisted cable: two ends both with T568B line series
2. PC Setting & Programmer VersionWe use “Mini Programmer (Version 2.00)” as the tool to update the scale. As it
needs a default visual IP address for the PC by this kind of update method, You must set your PC’s IP address within the range of 10.10.10.1-----10.10.10.240, before you start the software to update the scale.If you don’t set the IP address like this, you can see an alarm window as Pic. 1 when you start “Mini Programmer”.
Pic. 1
3. Updating Steps1) How to start ethernet updating?
A. Turn on the switch on the bottom of the scale. B. Power off the scale by pressing On/Off Key.C. After that, press and hold [Re-Zero] and [Preset 22], then start the scale by
pressing the On/Off Key.D. The screen will display the version of the current boot program for two seconds.E. Only in new versions(version of the boot program newer than 1.10), you
can choose 2-ethernet.
2) Display on the scale’s screenA. If you choose 2 and the scale’s connection is correct, it will display “waiting for
connect”.B. Then the message on the scale’s screen is “getting IP address”. C. After this, it will display “001 scale ready update”.D. You can’t stop it unless you press On/Off key. If you want to continue
updating. You also don’t need to press any key on the scale until Mini Programmer begin to run.
3) How to upload the scale by Mini Programmer?A. Select SM-100 and press “ok”
B. Set the port
Select “ethernet” and press “OK”
C. Download boot program and update the scaleSelect menu “File->Load File To Programmer Buffer”
Open the source file of boot program (e.g. sm100bv100.hex)
You can see a speed mode select window here.
Select menu “Flash->Program”
Notice: The message “001 scale ready update” must be displayed on the
screen of the scale before pressing the “run” button.
After the transmission has completed, select menu “File->Clear Buffer”.
Notice: 1.If the boot program of this version is already in the scale, you don’t need to upload it again, skip it and upload the main program.
2.If the scale is updated from 1.xx to 2.xx,firstly you must update the boot program of the version.
D. Download main program fileYou must power off the scale and start the ethernet upload method again when you have finished a program uploading.The steps of uploading the main program file is also like uploading the boot program file. The file you need to open is like Pic. 2
Pic. 2
E. Download word-stock fileThe steps of uploading the word-stock file is also like uploading the boot program file. The file you need to open is like Pic. 3
Pic. 3
F. Download const text fileThe steps of uploading the const text file is also like uploading the boot program. The file you need to open is like Pic. 4
Pic. 4
G. Exit Mini Programmer
Note: please update the scale according to sequence above.
RS232C Method
4. Cable Connection3 Pins are used for data transmission between PC and SM-1009 Pin D-Sub Female Connectors for this cable:
PC Serial Port SM-100 RS-232C9 Pin D-Sub (Female) 9 Pin D-Sub (Female)
Pin Signal Signal Pin1 N.C. N.C. 12 RXD RXD 23 TXD TXD 34 N.C. N.C. 45 GND GND 5
6 - 9 GND N.C. 6 - 9
5. Update Steps1) How to start RS232C updating
A. Turn on the switch on the bottom of the scale.B. Power off the scale by pressing the On/Off Key.C. After that press and hold [Re-Zero] & [Preset 22], then start the scale by press
ing the On/Off Key.D. It will display the version of the current boot program for two seconds.E. If the scale boot version is newer than 1.10, it will display a updating method
choice like “1-RS232 2-ETHERNET” on the screen. you can press Numeric 1 to choose 1-RS232C.
If the boot version is older than 1.10, the scale will not display the choice.F. Then the Scale will display “PROGRAM”. You can’t stop it, unless you press
Tare or On/Off Key.
2) Start Mini Programmer
1. Select SM-100 and press “Ok”
2. Set the Port:
Select RS232 and press “OK”
3. Download the boot program and update the scaleSelect menu “File->Load File To Programmer Buffer”
Open the source file of the boot program (e.g. sm100bv100.hex)
Select menu “Flash->Program”
Notice: The message “001 scale ready update” must be displayed on the scale before pressing the “run” button.
After the transmission has completed, select menu “File->Clear Buffer”.
Notice: If the boot program of this version is already in the scale, you don’t need to upload it again, skip it and upload the main program.
4. Download main program fileYou must power off the scale and start the ethernet upload method again when you have finished a program uploading.The steps of uploading the main program file is also like uploading the boot program file. The file you need to open is like Pic. 2
Pic. 2
5. Download word-stock fileThe steps of uploading the word-stock file is also like uploading the boot program file. The file you need to open is like Pic. 3
Pic. 3
6. Download const text fileThe steps of uploading the const text file is also like uploading the boot program. The file you need to open is like Pic. 4
Pic. 4
7. Exit Mini Programmer
4.2 SPECIFICATION SETTINGBefore Specification setting, please press the mode button to enter Z mode. The detail specification list , please see the appendix.
4.2.1 Customer SPEC Setting
To change setting of the Customer SPEC if there are some SPEC setting in it need to be alter.
OPERATIONDISPLAY
REMARKPT kg $/kg $
Z1.0 RESET SALES DAILYZ mode.
Lamp Z turns on.
[Rezero]+[1][4][1] SPEC 000XXX
(setting)
XXX
(former)
Enter [1][4][1] while depressing
[Rezero].
XXX:SPEC data
[︾] SPEC 001 XXX XXX[ ︾ ]key only increase specification
count, it does not update SPEC data.
[︽] SPEC 000 XXX XXX[︽]key only decrease specification
count, it does not update SPEC data.
[1][7]
[X]
SPEC 000
SPEC 017
017
XXX
XXX
XXX
It goes to a designed specification
count.
(000~441 is enabled)
[>>] SPEC 017 XXX XXX[>>] key select SPEC data.
Move cursor right.
[<<] SPEC 017 XXX XXX[<<] key select SPEC data.
Move cursor left.
[1]
[*]
SPEC 017
SPEC 018
001
XXX
XXX
XXX
[C] SPEC 018 000 XXX Clear the enter data.
[PLU]
* Note 1Z1.0 RESET SALES DAILY
Store the updated specification and
escape to Z mode.
* Remark: The Weight in the display window will display the SPEC number. The Unit Price window will display the new value setting entered. The Total Price window will display the old value setting. The selection you have made will be highlighted in thedot matrix display. Please use [︾] to increase spec count, [︽] to decrease spec count,[*] to store a new value and [PLU] to save spec setting.
4.2.2 Weight & Measurement SPEC Setting
To change the setting of the Weight & Measurement SPEC if there are some SPEC need to alter. (Please turn on the span switch when using this process)
OPERATIONDISPLAY
REMARKPT kg $/kg $
Press SPAN
SWITCHZ1.0 RESET SALES DAILY SPAN SWITCH is on(ENABLE).
[Rezero]+[1][4][2] SPEC 600XXX
(setting)
XXX
(former)
Enter [1][4][2] while depressing
[Rezero].
XXX:SPEC data
[︾] SPEC 601 XXX XXX[ ︾ ]key only increase specification
count, it does not update SPEC data.
[︽] SPEC 600 XXX XXX[︽]key only decrease specification
count, it does not update SPEC data.
[6][1][5]
[X]
SPEC 600
SPEC 615
615
XXX
XXX
XXX
It goes to a designed specification
count.
(600~709 is enabled)
[>>] SPEC 615 XXX XXX[>>] key select SPEC data.
Move cursor right.
[<<] SPEC 615 XXX XXX[<<] key select SPEC data.
Move cursor left.
[1]
[*]
SPEC 615
SPEC 616
001
XXX
XXX
XXX
[*] key to update specification,
increase specification count.
[2] SPEC 616 002 XXX
[C] SPEC 616 000 XXX Clear the enter data.
[PLU]
* Note 1Z1.0 RESET SALES DAILY
Store the updated specification and
escape to Z mode.
Note 1: If press [T] key, it does not store the updated specification and escape to Z mode.
* Remark: The Weight in the display window will display the SPEC number. The Unit Price window will display the new value setting entered. The Total Price window will display the old value setting. The selection you have made will be highlighted in thedot matrix display. Please use [︾] to increase spec count, [︽] to decrease spec count,[*] to store a new value and [PLU] to save spec setting.
SM100 ADJUSTMENT
5. ADJUSTMENT
5.1 PEEL SENSOR VOLTAGE AND LABEL SENSOR SENSITIVITY ADJUSTMENT
Label Sensor
LOCATION OF PEEL AND LABEL SENSOR
SM100 ADJUSTMENT
5.1.1 Peel Sensor Voltage
To set the peel sensor voltage if the peel sensor is not working normally in some situations like temperature and humidity change.
OPERATIONDISPLAY
REMARKPT kg $/kg $
Z1.0 RESET SALES DAILYZ mode.
Lamp Z turns on.
[Rezero]+[5][1][5] PEEL PFD 0.5 0.0
Enter [5][1][5] while depressing
[Rezero].﹩/kg window displays label paper peel sensor voltage, ﹩ window
displays new setting value.
[T] Z1.0 RESET SALES DAILY [T] key to exit.
5.1.2 Label Sensor Sensitivity
Adjust here for sensor
When the label came out three or more when feeding or printing, the sensitivity of the sensor need to be adjusted to sense the gap between the label better. There is a variable resistor near the sensor. Adjust it to increase or decrease the sensitivity. Clockwise is to increase the sensitivity and anti-clockwise is to decrease the sensitivity.
SM100 ADJUSTMENT
OPERATIONDISPLAY
REMARKPT kg $/kg $
Z1.0 RESET SALES DAILYZ mode.
Lamp Z turns on.
[Rezero]+[5][1][6] GAP PFD 2.0 3.1
Enter [5][1][6] while
depressing [Rezero].﹩/kg window
displays label paper
gap sensor
voltage, ﹩window
displays new setting
value.[T] Z1.0 RESET SALES DAILY [T] key to exit.
SM100 ADJUSTMENT
5.2 ADJUSTMENT OF PRINTING POSITION
This function is used to adjust the print position on label.
OPERATIONDISPLAY
REMARKPT kg $/kg $
Z1.0 RESET SALES DAILYZ mode.
Lamp Z turns on.
[Rezero]+[5][1][4] ADJ PFD 0 0
Enter [5][1][4] while depressing
[Rezero].﹩/kg window display old setting, ﹩
window display new setting.
[1][0] ADJ PFD 0 10
To move up the point position on
label, enter the new value by numeric
key (Ex. 10 dots).
[1][0][-] ADJ PFD 0 -10
If you want to move down the print
position, please enter the new value
by numeric key (Ex. 10dots), and
then press [−] key.
[PLU] 0.000 0.000 0.00 0.00 Save the feed setting.
[T] Z1.0 RESET SALES DAILYIf you want to exit without saves the
setting, press [T] key to exit.
PRINTING TOO HIGH CORRECT POSITION PRINTING TOO LOW (ADJUST DOWNWARD) (ADJUST UPWARD)
SM100 ADJUSTMENT
5.3 VOLTAGE CHECKPOINT
There are several voltage checkpoints on the PCB boards. Below are some reference voltage points that are commonly use.
VOLTAGE POINT VOLTAGE PURPOSEVCC 3.3 V Provide voltage for most of the IC
VTH 24 V Provide voltage mainly to the thermal head
VBB 3 V Provide backup voltage for the RAM IC
HVcc 5 V
The tolerance of all the voltage is about ± 5% except VTH is +2% and -5%
SM100 INTERFACE
39
6. INTERFACE
6.1 PC INTERFACE
SM 100 can be connect to PC through Ethernet interface and RS232C. See below for the connection method.
CONFIGURATION OF PC ETHERNET CARD
Window version client driver Any Ethernet cards can be used for PC running the Window version client driver
Windows 98
My Computer → Control Panel → Network→TCP/IP of Ethernet card (Select Properties)
IP address : 192.168.1.XXX ------ XXX - can be any number. But preferable 100 to 255.
Submask : 255.255.255.0
Above IP address is use as a standard address to use for SM 100 Ethernet communication.
If whatever reason, the IP address had to be change, it may do so. But the scale IP address had to be change at the SM 100 scale also so that they are within the same network. Eg. If the computer IP address is 192.168.1.XXX, the SM 100 scale IP address has to be change to 192.168.1.XXX. The last three digits of the IP address should not be similar within the computer and scales at all time. As can see the first three set of number of the IP address of the computer and scale must be the same.
40
SM100 INTERFACE
Before setting the SPEC setting of the scale, please check below.
6.2 SCALE ETHERNET ADDRESS
The main board have a Scale Ethernet Address that is set during production. This address is a hardware setting for Ethernet communication. But when changing a new main board, the new main board did not have any this address. If the scale is using Ethernet communication, a Scale Ethernet Address is needed apart from software IP address. Please take note that the Scale Ethernet Address can only input once after saving. Please view and note down the Scale Ethernet Address of the old main board before changing the new main board. Below procedure is to view and input the Scale Ethernet Address. Please turn on the span switch before proceed.
KEY TO PRESS DISPLAY OPERATIONPT kg $/kg $
Go to Z mode Z1.0 RESET SALES Daily At Z mode[REZERO] +[0][6][1][2]
ETHER NET ……. ……. Viewing of Ethernet address For new main board, it can act as input of the address if the address shown …….. Else it would not let you to input.
[0][0][0][6][C][0] [0][0][0][0][2][4]
ETHER NET 0006C 0000024 For input only. EnterEthernet address e.g.0006C 0000024
[PLU] Z1.0 RESET SALES Daily Save address and escape to Zmode. After saving it will not be able to input again.
[T] Z1.0 RESET SALES Daily Escape to Z mode without saving.
Power off the scale Turn off the power and do the memory clear process.
* IMPORTANT : Please take note that this is a one time setting. It cannot be change after setting it. Please check the old address and input accordingly. As same internal Ethernet address in a network may conflict during communication.
6.3 SCALE IP ADDRESS
41
SM100 INTERFACE
This is to set the IP address for PC communication using Ethernet for specific IP address. It should not be confused with the Scale Ethernet Address as above. The Scale Ethernet Address is mainly for hardware and Scale IP Address is for software. The software when communicating to the scale must specify the same IP address on the scale else it will give error. The default is 192.168.000.000 where the last three digit will change when SPEC 135 change. Please turn on the span switch before proceed.
KEY TO PRESS DISPLAY OPERATIONPT kg $/kg $
Go to Z mode Z1.0 RESET SALES Daily At Z mode[REZERO] +[0][4][1][6]
SCALE IP ……. ……. Input or viewing of IPaddress
[1][9][2][1][6][8] [0][0][1][0][1][6]
SCALE IP 192168 001016 Enter IP address e.g.192.168.001.016( The last 3 digits cannot be input as it will change when SPEC 135 change)
[PLU] Z1.0 RESET SALES Daily Save address and escape to Zmode
[T] Z1.0 RESET SALES Daily Escape to Z mode without saving.
42
SM100 INTERFACE
6.4 CONNECTION METHOD
6.4.1 RS232C Interface with PC
PC Scale
Com 1 / Com 2 RS232C Port
* Note : Only 1 scale can be connect in this method.
SPEC setting on scale :
SPEC 48 Scale number (For 4 line / RS232C port) Enter number between 1 to 999,999
SPEC 51 Baud rate for SIO (RS232C port) 0 1200 2 4800 4 192001 2400 3 9600 5 384006 76800
SPEC 52 Data length for SIO (For RS232C port) 0 7 bit 1 8 bit
SPEC 53 Parity for SIO (For RS232C port) 0 None 1 Odd 2 Even
SPEC 54 Stop bit for SIO (For RS232C port) 0 1 bit 1 2 bits
6.4.2 Ethernet Connection (Ethernet Interface)
43
SM100 INTERFACE
Scale #1 Scale #2 Scale #3 Scale #4 Scale #5
PC
HUB
SPEC setting on scale :
SPEC 49 CLIENT / SERVER INTERFACE 0 No interface 3 Not used1 Ethernet - Coaxial Cable 4 4 lines, RS485 (For future use)2 Ethernet - Twisted Cable
SPEC 50 CLIENT / SERVER 0 Client 2 Back-up server1 Server / Workstation
SPEC 135 PORT NUMBER * Enter number from 1 to 254
PIN SIGNAL SIGNAL PIN1 TX+ TX+ 32 TX- TX- 63 RX+ RX+ 16 RX- RX- 2
5,7,8 N.A. N.A. 5,7,8
44
SM100 INTERFACE
6.5 WIRE CONFIGURATION
6.5.1 Ethernet Wire - Straight Cable and Crossover Cable
Straight cable is for Client / Server connection. Crossover cable is for Hub to Hub connection. (Some models of the hub do not need crossover cable for hub to hub connection. Please refer to the hub operation manual if in doubt)
Telephone Modular Plug (Category 5) -
Preferable type : CviLux CJP3 / CviLux CJP4 (with insert bar)
CABLE TYPE -
Cable type : 4 pair 100MHz Cat.5 AWG 24 or 26 UTP / FTP / STP.
Preferable type : Cat. 5 AWG 24 or 26 FTP / Cat. 5 AWG 24 or 26 STP(Recommended for CISPR 22B conformance)
PIN CONFIGURATION
1 8
SM 100 HUB
8 1Solder to braid wire of the Ethernet wire if using plug without insert bar
1 8
SM 100 HUB
8 Solder the braid wire of the Ethernet 1 wire if using plug with insert bar
STRAIGHT CONNECTION CROSSOVER CONNECTION
SCALE HUB HUB HUBPIN SIGNAL SIGNAL PIN
1 TX+ TX+ 12 TX- TX- 23 RX+ RX+ 36 RX- RX- 6
5,7,8 N.A. N.A. 5,7,8
PC 输入 Pin
Not used 1TXD 2RXD 3
Not used 4GND 5
Not used 6Not used 7Not used 8Not used 9
Pin Output 1 Not used.2 + 8 V3 GDD4 Not used.
Input Pin Not used 1Voltage + 2
GDD 3Not used 4
45
SM100 INTERFACE
6.5.2 RS232C Wire
PC (9 PIN) TO SCALE RS232C PORT
RS232C Port(9 Pin) PC COM Port(9 Pin)
RS-232Pin 输出1 Not used2 RXD3 TXD4 DTR5 GND6 DSR7 DTR8 DSR9 Not used
6.5.3 Cash Drawer ConnectorSM-100 uses normal phone mike plug to connect cash drawer and the scale.
1 pin
4 pin
1 pin
4 pin
Plug in the scale Connector of Cash Drawer
SM 100 MISCELLANEOUS
46
7. MISCELLANEOUS
7.1 MODE CHANGE
To toggle between R, X, S, Z and Password mode.
OPERATIONDISPLAY
REMARKPT kg $/kg $
0.000 0.000 0.00 0.00 Weight mode.Lamp R turns on.
[MODE],[MODE]
(within 3 seconds)XMODE
Enter X mode.Lamp X turns on.
[MODE] S1 → PLU FILE Enter S mode.Lamp S turns on.
[MODE] Z1.0 RESET SALES DAILY Enter Z mode.Lamp Z turns on.
[MODE] PWD X 0 SETEnter Password Set mode.Lamp X
flicker
[MODE] 0.000 0.000 0.00 0.00 Back to Weight mode.Lamp R turns on.
** The “X ” mark on the X, S, Z and R mean the indicator light is on. When in Passwomode, theindicator light will be blinking.
7.2 SPAN SWITCH STATUS
To check the status of the span switch.
OPERATIONDISPLAY
REMARKPT kg $/kg $
Go to Z mode Z1.0 RESET SALES DAILYZ mode.
Lamp Z turns on.
[Rezero]+[2][8][4] STE16 VX.XX S-OFFEnter [2][8][4] while depressing
[Rezero].
Z1.0 RESET SALES DAILY Exit after 3 seconds.
7.3 CLEAR ALL PLU DATA
To clear all the PLU data only, the span switch status must be on.
OPERATIONDISPLAY
REMARKPT kg $/kg $
Go to Z mode Z1.0 RESET SALES DAILYZ mode.
Lamp Z turns on.
[Rezero]+[2][3][0] CLEAR PLU FILEEnter [2][3][0] while depressing
[Rezero].
* CLEAR PLU Y--C N--T Enter C for Yes, Enter T for No..
C(T) Z1.0 RESET SALES DAILY Back to Z mode
7.4 THERMAL HEAD USAGE
47
SM 100 MISCELLANEOUS
To check how many time the thermal head had been printing.
OPERATIONDISPLAY
REMARKPT kg $/kg $
Go to Z mode Z1.0 RESET SALES DAILYZ mode.
Lamp Z turns on.
[Rezero]+[0][8][2][3] PRINTER USAGE 5Display thermal printer usage
condition(meter).
[T] Z1.0 RESET SALES DAILY [T] key to exit.
7.5 IP ADDRESS
To check and modify the scale IP address.
OPERATIONDISPLAY
REMARKPT kg $/kg $
Go to Z mode Z1.0 RESET SALES DAILYZ mode.
Lamp Z turns on.
[Rezero]+[0][4][1][6] SCALE IP 19216800 0000 Display the scale IP address.
[1][9][2][0][0]
[9][1][0] [0]SCALE IP 19200910 0000
Modify the IP address.
[#] ----------Save the new IP address.
Press [T] key to exit.
7.6 SERVER IP ADDRESS
To check and modify the server IP address.
OPERATIONDISPLAY
REMARKPT kg $/kg $
Go to Z mode Z1.0 RESET SALES DAILYZ mode.
Lamp Z turns on.
[Rezero]+[0][4][1]7] SERVER IP 25525525 5000 Display the server IP address.
[1][9][2][0][0]
[9][1][0] [0]SCALE IP 19200910 0000
Modify the server IP address.
[#] ----------Save the new IP address.
Press [T] key to exit.
7.7 SUBNET MASK
48
SM 100 MISCELLANEOUS
To check and modify the subnet mask.
OPERATIONDISPLAY
REMARKPT kg $/kg $
Go to Z mode Z1.0 RESET SALES DAILYZ mode.
Lamp Z turns on.
[Rezero]+[0][4][1]8] SERVER IP 25525525 5000 Display the server IP address.
[1][9][2][0][0]
[9][1][0] [0]SCALE IP 19200910 0000
Modify the server IP address.
[#] ----------Save the new IP address.
Press [T] key to exit.
7.8 MAC ADDRESS
To check the MAC address.Please turn on the span switch before proceed.
OPERATIONDISPLAY
REMARKPT kg $/kg $
Go to Z mode Z1.0 RESET SALES DAILY Z mode.
Lamp Z turns on.
[Rezero]+[0][6][1]2]ETHERN
ET0006C071 96BE
Display the MAC address.
[T] Z1.0 RESET SALES DAILY Press [T] key to exit.
7.9 SERIAL NO
To check the serial NO..
OPERATIONDISPLAY
REMARKPT kg $/kg $
Go to Z mode Z1.0 RESET SALES DAILYZ mode.
Lamp Z turns on.
[Rezero]+[1][1][1] SCALE S/N 05386686 Display the serial NO..
[T] Z1.0 RESET SALES DAILY Press [T] key to exit.
8.0 ASCII CHARACTERBelow are the common use of characters of ASCII code in HEX value. Please enter the hex value when entering commodity name, advertisement, shop name, clerk name, special message, ingredient, text etc. when using the SM-100.
A B C D E F G H I J K L M
49
SM 100 MISCELLANEOUS
41 42 43 44 45 46 47 48 49 4A 4B 4C 4DN O P Q R S T U V W X Y Z4E 4F 50 51 52 53 54 55 56 57 58 59 5Aa b c d e f g h i j k l m
61 62 63 64 65 66 67 68 69 6A 6B 6C 6Dn o p q r s t u v w x y z
6E 6F 70 71 72 73 74 75 76 77 78 79 7A0 1 2 3 4 5 6 7 8 9 ! @ #
30 31 32 33 34 35 36 37 38 39 21 40 23$ % ^ & * ( ) : ; " ' + <
24 25 5D 26 2A 28 29 3A 3B 22 27 2B 3C> = / ? · , Space
3E 3D 2F 3F 2E 2C 20
Specification List SM-100 V2.00 26 December, 2006
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 1 of 32
TITLE : SM-100 SPECIFICATION LIST REVISION NO. : 0ISSUED DATE : 17 August, 2004
Rev.No.
Modification DetailsSoftwareVersion
0 First Release 1.00
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 2 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
CUSTOMER SPECIFICATION [REZERO] + [1][4][1]
00 Item Barcode 90 F1F2 CCCCC XCD XXXX CD 13 F1X2 CCCCCC XXXX CD1 F2 CCCCCC XCD XXXX CD 14 F1F2 CCCC XCD XXXXX CD2 F1F2 CCCCC 0 XXXX CD 15 F2 CCCCC XCD XXXXX CD3 F1F2 CCCCCC XXXX CD 16 F1F2 CCC XXXXXXX CD4 F1F2 CCCCC XXXXX CD 17 F1F2 CC XXXXXXXX CD5 F2 CCCCCC XXXXX CD 18 CCC WWWW PPPPP CD6 F2 CCCCC XXXXXX CD 19 No Barcode7 F1F2 CCCCCCCCCC CD #1 20 F1F2 CCCCC PCD XXXX CD8 F1F2 CCCC XXXXXX CD9 F1F2 CCCCC CD #210 F2 CC XXXX CD #311 No Barcode12 F1X2 CCCCC XCD XXXX CD
All are 13 digits non-PLUbarcode unless otherwise stated.#1 13 digits PLU
barcode#2 8 digits PLU barcode#3 8 digits non-PLU
barcode
01 Right Side Data of Item Barcode 90 Quantity 4 Original Price1 Price 5 Weight / Quantity2 Weight 6 Unit Price3 User Programmable # 7 Unit Price after discount
# Related to SPEC153.
02 Right Side Price Data of Item Barcode 90 Price before Tax 1 Price after Tax Effective when SPEC1 =
103 Flag Data F1 and F2 for 13 Digits Non-PLU Barcode 9
Enter value from range 0 to 9904 Flag Data F1 and F2 for 13 Digits PLU Barcode 9
Enter value from range 0 to 9905 Flag Data F2 for 8 Digit Non-PLU Barcode 9
Enter value from range 0 to 906 Flag Data F1 and F2 for 8 Digit PLU Barcode 9
Enter value from range 0 to 9907 Total Barcode 9
0 F1F2 CCCCC XCD XXXX CD 12 F1X2 CCCCC XCD XXXX CD1 F2 CCCCCC XCD XXXX CD 13 F1X2 CCCCCC XXXX CD2 F1F2 CCCCC 0 XXXX CD 14 F1F2 CCCC XCD XXXXX CD3 F1F2 CCCCCC XXXX CD 15 F2 CCCCC XCD XXXXX CD4 F1F2 CCCCC XXXXX CD 16 F1F2 CCC XXXXXXX CD5 F2 CCCCCC XXXXX CD 17 F1F2 CC XXXXXXXX CD6 F2 CCCCC XXXXXX CD 18 CCC WWWW PPPPP CD7 F1F2 CCCCCCCCCC CD #1 19 No Barcode8 F1F2 CCCC XXXXXX CD 20 F1F2 CCCC PCD XXXX CD9 F1F2 CCCC CD #210 F2 CC XXXX CD #311 No Barcode
All are 13 digits non-PLUbarcode unless otherwise stated.#1 13 digits PLU
barcode#2 8 digits PLU barcode#3 8 digits non-PLU
barcode
08 Left Side Data of Total Label 90 Scale No. 3 Clerk No.1 Last Accumulated Item Code 4 Fixed No.2 Receipt No.
09 Fixed Data for Left Side Data of Total Barcode 9Enter value from range 0 to 9 999 999 999
10 Flag Data F0, F1 and F2 for Total Barcode 9Enter value from range 0 to 999
11 Right Side Data of Total Barcode 90 Quantity 2 Weight1 Price
12 Total Barcode Print on Receipt 90 No 1 Yes
13 Print Readable Character of F1 for Item and Total Barcode (for EAN only) 80 No Print 1 Print
14 Printing Position for Advertisement Message 90 First Line 2 Above1 Below 3 Not Used
15 Turnover Printing for Advertisement Message0 No 1 Yes
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 3 of 32
Specification List SM-100 V2.00 26 December, 2006
16 Exit from “Change” Mode within Specified Interval 90 No 3 10 sec1 3 sec 4 15 sec2 6 sec
17 Order of the Month, Day and Year for Print 90 MM/DD/YY 2 YY/MM/DD1 DD/MM/YY 3 Not Used
18 1 or 2 Line(s) Commodity Name on Receipt 90 2 Lines 2 No Print1 1 Line
19 Label Printing by Clerk Key 90 No Print 2 Print without Accumulated1 Print with Accumulation
20 Total Label Printing 90 No Print 1 Print
21 Printing Operator Name on Receipt and Label 90 Code 1 Name
22 Receipt Paper Width 80 60 mm 2 50 mm1 40 mm
23 Manual Price Entry for Printing or Accumulating 90 Allow 1 Inhibit
24 Default Label Format for Item Printing 90 T1 (A) 12 S (T7)1 T2 (B) 13 A (T8)2 T3 (C) 14 B (T9)3 T4 (U2) 15 C (T10)4 T5 (U3) 16 F1 (F1)5 T6 (U4) 17 F2 (F2)6 T7 (U5) 18 F3 (F3)7 T8 (U6) 19 F4 (F4)8 T9 (U7) 20 F5 (F5)9 T10 (U8) 21 F6 (F6)10 T11 (T5) 22 F7 (F7)11 T12 (T6) 23 F8 (F8)
Formats in ( ) are for U1and CA only.
F1 to F8 are FreeFormat.
25 Default Label Format for Total Printing 90 T1 (A) 12 S (T7)1 T2 (B) 13 A (T8)2 T3 (C) 14 B (T9)3 T4 (U2) 15 C (T10)4 T5 (U3) 16 F1 (F1)5 T6 (U4) 17 F2 (F2)6 T7 (U5) 18 F3 (F3)7 T8 (U6) 19 F4 (F4)8 T9 (U7) 20 F5 (F5)9 T10 (U8) 21 F6 (F6)10 T11 (T5) 22 F7 (F7)11 T12 (T6) 23 F8 (F8)
Formats in ( ) are for U1and CA only.
F1 to F8 are FreeFormat.
26 Shop Name Printing on Label 90 No Print 1 Print
27 Forced Tare Function 90 Disable 1 Enable
28 Peel Sensor Function in Prepack Mode 90 Disable 1 Enable
29 Continuous Print for Label in Prepack Mode 90 Inhibit 1 Allow
30 Selection of CDV 80 Inhibit 1 Allow For SF only.
31 CDV Type 80 CDV 1 Tear-off For SF only.
32 CDV Modulus 80 Modulus 10 1 Modulus 11 For SF only.
Effective when SPEC30 and 31 = 1.
33 On Spot Correction 90 Allow 1 Inhibit
34 Search Correction 80 Allow 1 Inhibit
35 Move Back Correction 90 Allow 1 Inhibit
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 4 of 32
Specification List SM-100 V2.00 26 December, 200636 Past Sales Data Correction
0 Allow 1 Inhibit37 Label Print Density 9
0 Low 2 High-mid1 Mid 3 High
38 Receipt Print Density 90 Low 2 High-mid1 Mid 3 High
39 Calling of PLU 90 Manual 2 Time-out1 Auto
Related to SPEC40.
40 PLU Digits for Auto PLU Calling/Time-out Calling 90 3 Digits / 0.5 sec 2 5 Digits / 1.5 sec1 4 Digits / 1.0 sec 3 6 Digits / 2.0 sec
Effective when SPEC39= 1.
41 Unit Price of Weigh PLU Can Use for Price of Non-weigh PLU and Vice Versa 90 Allow 1 Inhibit Effective when SPEC643
= 0.42 Unit Price Override 9
0 Allow 1 Inhibit43 Main Usage for Commodity Name, Shop Name and Special Message 9
0 Receipt 1 Label Always set to 0 for SM-200.
44 Tare Override 90 Allow 1 Inhibit
45 Item Printing 90 Allow 1 Inhibit
46 Default Data of Printing Shop Name Number for Label 9Enter value from range 0 to 32
47 Default Data of Printing Shop Name Number for Receipt 9Enter value from range 0 to 32
48 Setting of Scale Number 9Enter value from range 0 to 999 999
49 Type of Client / Server Interface 90 No Interface 3 Not Used1 Ethernet (Coaxial Cable) 4 4-Lines (RS-485)2 Ethernet (Twisted Pairs)
Related SPECs for Ethernet I/F are SPEC50, 135, 214.
50 Setting of Client / Server 90 Client 2 Backup Server1 Server / Workstation
Related SPECs for S/Csetting are SPEC61, 150,163, 165, 187, 194, 208,229, 252, 253, 254, 255,265, 276.
51 Baud Rate of SIO (RS-232C Port) 90 1 200 bps 4 19 200 bps1 2 400 bps 5 38 400 bps2 4 800 bps 6 76 800 bps3 9 600 bps
Apply to both RS-232Cand RS-485 ports setting for SM-300.Related SPECs areSPEC48, 52, 53, 54, 60,134.
52 Data Length of SIO (RS-232C Port) 90 7 Bits 1 8 Bits Apply to both RS-232C
and RS-485 ports setting for SM-300.
53 Parity Bit of SIO (RS-232C Port) 90 None 2 Even1 Odd
Apply to both RS-232Cand RS-485 ports setting for SM-300.
54 Stop Bit of SIO (RS-232C Port) 90 1 Bit 1 2 Bits Apply to both RS-232C
and RS-485 ports setting for SM-300.
55 Baud Rate of Multi-drop SIO (RS-485 / 4-Lines Port) 80 1 200 bos 3 9 600 bps1 2 400 bps 4 19 200 bps2 4 800 bps 5 38 400 bps
Related SPECS areSPEC48, 56, 57, 58, 59,134.
56 Data Length of Multi-drop SIO (RS-485 / 4-Lines Port) 80 7 Bits 1 8 Bits
57 Parity Bit of Multi-drop SIO (RS-485 / 4-Lines Port) 80 None 2 Even1 Odd
58 Stop Bit of Multi-drop SIO (RS-485 / 4-Lines Port) 80 1 Bit 1 2 Bits
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 5 of 32
Specification List SM-100 V2.00 26 December, 200659 Multi-drop SIO (RS-485 / 4-Lines Port) Select Job 8
0 No Operation 2 Pick ‘N’ Pay #21 FIS 3000 #1
#1 Either SPEC59 or 60can be selected at any one time.#2 For SF only.
60 SIO (RS-232C Port) Select Job 80 No Operation 3 Point ‘N’ Shop1 FIS 30000 #1 4 Barcode Scanning2 FL-1 5 Video Control #2
Apply for both RS-232Cand RS-485 ports setting for SM-300.#1 Refer to SPEC59’scomments #1.#2 For SM-300 only
61 Floating Clerk 80 Inhibit 1 Allow
62 Receipt Free Format 80 Disable 1 Enable Exclude AA.
63 SM-90 and DI-10 RS-232C Communication 80 No 1 Yes
64 Enable Password Mode 90 Allow 2 Allow Multi Password1 Inhibit
65 Report Printing in Daily and Term Transaction Clear 90 Inhibit 1 Allow
66 Pack Quantity Function Key Enable 90 Allow 1 Inhibit
67 Advertisement Function Key Enable 9
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 6 of 32
Specification List SM-100 V2.00 26 December, 20060 Allow 1 Inhibit
68 Fixed Total Price Discount Function Key Enable 90 Allow 1 Inhibit
69 Total Price Percentage Discount Function Key Enable 90 Allow 1 Inhibit
70 Fixed Unit Price Function Key Enable 90 Allow 1 Inhibit
71 Fixed Unit Price Percentage Function Key Enable 90 Allow 1 Inhibit
72 Pack Date Function Key Enable 90 Allow 1 Inhibit
73 Minus Pack Date Function Key Enable 90 Allow 1 Inhibit
74 Sell by Date Function Key Enable 90 Allow 1 Inhibit
75 Unit Symbol Function Key Enable0 Allow 1 Inhibit
76 Quantity Set Function Key Enable0 Allow 1 Inhibit
77 Price Change Function Key Enable0 Allow 1 Inhibit
78 Refund Item Function Key Enable 90 Allow 1 Inhibit
79 Shop Name Function Key Enable 90 Allow 1 Inhibit
80 Logo Function Key Enable 90 Allow 1 Inhibit
81 Print Select Function Key Enable 90 Allow 1 Inhibit
82 Print of Place of Production on Label 90 Inhibit 1 Allow
83 Selection of Markdown 90 No Markdown 2 Total Price Markdown1 Unit Price Markdown 3 Unit and Total Price Markdown
84 Sub-total Function Key Enable 90 Allow 1 Inhibit
85 Grand Total Function Key Enable 90 Allow 1 Inhibit
86 Label Sensor Gap Value 8Enter value range from 0 to 255
87 Label Type 90 Gap 1 No Gap
88 Sell by Date Title Print out 80 Inhibit 1 Allow For AA only.
89 ASCII Code Entry in S Mode 80 Inhibit 1 Allow For AA only.
90 Sub-total Markdown 90 No Markdown 1 Markdown
91 Printer Speed for Receipt 90 Slow 2 High1 Normal
92 Printer Speed for Label 90 Slow 2 High1 NormalPrinter Strode 80 Single 2 Not Used1 Double
93 Print Second Receipt 90 No Print 3 3 sec Delay1 Continuous Print 4 User Select2 1 sec Delay
94 Position of Currency Symbol (on Label) 90 Before Price 1 After Price
95 Receipt Printing with Dual Copy 80 Inhibit 1 Allow
96 Advertisement Message on All Label 90 Inhibit 1 Allow
97 Manual Print in Prepack Mode for Weigh Item 90 Inhibit 1 Allow
98 Quantity and Unit Symbol Print Out for Non-weigh Item in Manual Mode 90 Allow 1 Inhibit
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 7 of 32
Specification List SM-100 V2.00 26 December, 200699 Unit Print Out for Non-weigh Item in Manual Mode 8
0 Inhibit 1 Allow100 Discount in PLU Programming 8
0 Allow 1 Inhibit101 Zero Suppress for Date and Time 9
0 Disable 1 Enable102 Discount Presentation in Receipt 8
0 Discounted Unit Price and 1 Original Unit Price and PriceOriginal Price
103 Unit Price Assignment Function Key for PLU0 Enable 1 Disable
104 Discount Price Rounding Method 90 Rounding 2 Cut Up1 Cut Down
105 Fixed Total Price Markdown Function Key Enable 90 Allow 1 Inhibit
106 Total Price Percentage Markdown Function Key Enable 90 Allow 1 Inhibit
107 Fixed Unit Price Markdown Function Key Enable 90 Allow 1 Inhibit
108 Fixed Unit Price Percentage Markdown Function Key Enable 90 Allow 1 Inhibit
109 Source of Sell by Date 90 Real Time Clock 1 Packed Date
110 Year Type 80 Standard 1 Japanese / Taiwan For AA and TW only.
111 Price Symbol on Receipt 80 No Print 2 Yen1 Kanji Yen
For AA only.
112 Default Data of Printing Special Message Number for Receipt 9Enter value range from 0 to 16
113 Label Logo Printing Status 90 No Print 3 Logo 31 Logo 1 4 Logo 42 Logo 2
114 Receipt Logo Printing Status0 No Print 4 Logo 31 Logo 1 5 Logo 42 Logo 2 6 Logo 1, 2, 3 and 43 Logo 1 and 2
115 Type of Entry for Used by Date and Sell by Date 80 By Day 1 By Hour For NICHII only.
116 Barcode Printing in First Label for Dual Label Printout 80 Print 1 No Print For NICHII only.
117 Zero Minutes Printing 80 No Print 1 Print For NICHII only.
118 Both Price before and after Discount 80 Price before and after Discount 1 Price before Discount only For NICHII only.
119 Unit Symbol Printout in Receipt 90 Depend on PLU Programming 2 No Print1 Japanese PCS
For AA only.
120 PLU Number Print 90 No Zero Suppress 1 Zero Suppress
121 Thick Japanese Character Printout 80 Thick Character 1 Thin Character For AA only.
122 Prepare Mode after Power On 80 Manual Mode 1 Prepack Mode Always set to 0 for SM-
200.123 Printing Thank You Message on Receipt 8
0 Enable 1 Disable124 PLU Unit Price after Discount 9
0 Unit Price after Discount 1 Unit Price Discount Amount125 Position of Special Message on Receipt 9
0 Bottom 1 Top126 Function Keys Protection for Self-service 8
0 No Protection 2 Partial Protection1 Full Protection
127 Printing of Checksum for Item Barcode0 Disable 1 Enable
128 Setting of Host Number (For SM-15 Multi-drop) 8Enter value between 0 to 99 For IR only.
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 8 of 32
Specification List SM-100 V2.00 26 December, 2006129 Type of Host to be Communicated 8
0 Standalone 2 POS ECR1 TMR ECR
For IR only.Use with SPEC128.
130 Selection of Print Item on Prepack Total Label 9 0 Based on Status on Item Label 1 Based on Status on Manual Total
Label131 Print PLU Setting Quantity in Manual Mode 9
0 No 1 Yes Effective when SPEC98= 0.
132 Receipt Total Report 80 No 1 Yes For DM only.
133 Change All PLU Default Format when Default SPEC Change 90 Yes 1 No
134 Host Communication 80 No Operation 1 EnableHost Communication0 RS-232C 1 RS-485
135 Port Number 9 Enter value from range 1 to 254
136 One or Two Touch for Self-service Operation 90 One Touch 1 Two Touches
137 Centering of Ingredient Data 90 Yes 1 No
138 Permanent Price or Discount Price Change via Function Key 90 No Update to PLU 1 Update to PLU
139 Number of Digits for Teraoka Code 80 2 Digits 1 3 Digits
140 AA Message Size 80 24 x 24 1 16 x 16 For AA only.
141 Year Format 90 YY 1 YYYY
142 Selection of Day Display for Sell by Date 90 Disable 1 Enable
143 Peel Sensor Trigger Voltage 80 High 1 Low
144 Display Prepack Quantity Balance 80 Enable 1 Disable
145 Print Select Function Across the Board 90 Disable 1 Enable
146 Label Format 1, 2 Function Key Enable 90 Inhibit 1 Allow Exclude AA.
147 Prepack Non-add Function Key Enable0 Inhibit 1 Allow Exclude AA.
148 FIS3000 Code 80 SM-80/90 FIS3D 1 SM-25 FIS3D
149 Main Group Function Key Enable0 Inhibit 1 Allow Exclude AA.
150 Preset Key Assignment for Client0 Local Assign 1 Central Assign
151 Change Sell by Date or Used by Date when Packed Date Changed0 No 1 Yes
152 Sell by Date or Sell by Time for Individual PLU0 Disable 1 Enable
153 User Programmable Right Side Data for Item Barcode 90 With Identification Digit 1 Without Identification Digit
154 Keysheet Letter Size 80 Small Letter 1 Capital Letter For FL & AS only.
155 Test Print on Receipt 80 No Print 1 Print For SD only.
156 Image Copy from Free Format 90 Disable 1 Enable
157 Training Mode 80 Disable 1 Enable Exclude DEC.
158 FSD Price and Image 80 Disable 1 Enable For U1 only.
159 ½ and ¼ Key Function 80 Disable 1 Enable
160 Twisted Pair Cable for Ethernet 80 Shield 1 Unshielded Not in used.
161 Discount Label Format 80 Enable 1 Disable For SD only.
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 9 of 32
Specification List SM-100 V2.00 26 December, 2006162 Item Code Function Key Enable
0 Enable 1 Disable163 Transaction Data Store in Client Memory
0 Disable 1 Enable164 Maximum Label Length 8
0 120 mm 1 240 mm165 Update Report for Client / Server System
0 Yes 1 No166 Average Price and Weight Label Function 9
0 Disable 1 Enable167 Label Date Title Print 9
0 No Print 1 Print Exclude AA.
168 GB Code 80 GB Code 1 Shift GB Code For CN and MS only.
169 Print PLU Setting Unit in Manual Mode0 No 1 Yes
170 User Specification (REZERO + 141) Accessible from Z Mode Only 80 No 1 Yes
171 Euro Mode 90 Disable 1 Enable
172 Dual Declarations 90 No 1 Yes For U1 only.
173 Mask 7-segment Display in X, S and Z Mode 80 No 1 Yes For double display types
only.174 Fixed Clerk Assign to Preset Key 8, 16, 24 and 32 8
0 Clerk Keys 1 Function Keys For bench type only.
175 30 lb to 15 kg Conversion 80 Disable 1 Enable For UK only.
176 Discount Time on Daily Basis 90 No 1 Yes
177 Weight Check Function 80 No 1 Yes
178 Unit Price Override per PLU 90 No 1 Yes
179 Black Bar Sensing Label 90 Normal 1 Black Bar Sensing
180 Scroll Message Group0 Disable 1 Enable
181 Continuos Label 90 Disable 1 Enable
182 Character Size for Barcode Data 90 Large 1 Small
183 PLU Clear after 10 seconds Time-out 80 No 1 Yes
184 Duplicate Unit and Total Price on Label 80 No Print 1 Print Effective when SPEC158
= 1.
185 Weigh PLU Can Use for Non-weigh PLU and Vice Versa Function Key Enable0 Disable 1 Enable
186 Print $ and Weight Unit on Label 90 No Print 1 Print
187 Clear Total Data by Server0 Both Server and Client 1 Server
188 Tare Decimal Point Left Shift for SM-25 FIS3D 80 No 1 Yes
189 PLU Auto Delete0 No Delete 2 30 Days1 15 Days 3 90 Days
190 Swap Weight and Unit Price on Receipt 80 No 1 Yes
191 Default Item Code Equals to PLU Number 90 No 1 Yes
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 10 of 32
Specification List SM-100 V2.00 26 December, 2006
192 Nutrition Template 80 Standard 3 Standard Condensed1 Simplified 4 Tabulated2 Simplified Condensed 5 Tabulated Extra Condensed
For U1 and CA only.
193 Nutrition Adjustment Feed 9Enter value from range 0 to 255 For U1 and CA only.
194 Server IP Address 9Enter a value between 1 to 254 For Client scale only.
195 Weight Print for Non-weigh Item 90 No 1 Yes
196 Scale File0 Disable 1 Enable
197 Print Format of Month 90 Number 2 3 Alphabetic1 2 Alphabetic
198 FSD Saving Calculation 80 Net Value 1 Cent Off For U1 only.
199 FIS3000 Time Out 80 2 sec 2 32 sec1 8 sec
200 PLU Call Up Range0 Disable 1 Enable
201 Sell by Date for Manual Mode0 Programmed Sell by Date 1 Zero Sell by Date
202 Printing of Item Label when Barcode Data Overflow 90 Print 1 No Print
203 Preset Keys Pages 90 1 Page 2 3 Pages by Shift Key1 3 Pages by Toggle
204 Reference PLU Function Key Enable0 Inhibit 1 Allow
205 Print Function Key Enable 80 Inhibit 1 Allow
206 Print Barcode when Right Side Data Overflow0 No print 1 Print Barcode Digits
207 Weight Decimal Point Position for Barcode and Label Printing 80 Same as SPEC607 1 0.000 Effective when SPEC607
= 2.208 Network Time Out 9
0 3 sec 2 x41 x2 3 x10
209 FSD Calculation 80 Unit Price 1 Price Percentage Off For U1 only.
210 PLU Repeat Function Key Enable0 Inhibit 1 Allow
211 Pick ‘N’ Pay Protocol 80 Old 1 New For SF only.
212 Department Number for Pick ‘N’ Pay 8Enter a value between 1 to 99 For SF only.
213 Flag Code Function Key Enable0 Inhibit 1 Allow
214 DHCP Function0 Disable 1 Enable
215 Centering of Special Message 90 Yes 1 No
216 JIS Code Table 80 New 1 Old For AA only.
217 Default Label Format 2 for Item Printing0 Not Used 5 F51 F1 6 F62 F2 7 F73 F3 8 F84 F4
218 Zero Unit Price for Unit Price Change Function Key0 Inhibit 1 Allow
219 Numeric Key Entry Reset 9
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 11 of 32
Specification List SM-100 V2.00 26 December, 20060 3 sec 2 Disable1 5 sec
For AA only.
220 Item Barcode Right Side Data Dependent on Unit 80 Disable 1 Enable Effective when SPEC1 =
0 or 2.221 Receipt with Tax Information Function Key Enable 8
0 Inhibit 1 Allow222 Open Cash Drawer without Sales Function Key Enable 9
0 Inhibit 1 Allow223 Negative Unit Price Function 8
0 Disable 1 Enable224 FIS3000 Wire Type 8
0 4 wires 1 2 wires225 Prepack Grand Total for Individual PLU
0 Yes 1 No226 Reverse Calculation of ITF Check Digit 9
0 No 1 Yes227 Unit Price Override Password Function
0 Inhibit 1 Allow Effective when SPEC178= 1.
228 Individual PLU Total Transaction 90 No 1 Yes
229 Preset Key Group0 Disable 1 Enable Effective when SPEC150
= 1.230 Auto Print after PLU Call 9
0 No 1 Yes231 Zero Unit Price for PLU and Unit Price Override 9
0 Inhibit 1 Allow232 Feed for Continuous Label 9
0 No 1 Yes233 Time Format 9
0 24 Hours 1 12 Hours (AM/PM)
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 12 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
234 Sub-total and Grand Total Barcode 90 Based on Item Barcode 1 Based on Total Barcode
235 Mask Barcode Last Human Readable Check Digit 90 No 1 Yes
236 Character Generator for Korea 80 Old 1 New For KE only.
237 Half-key Function0 Inhibit 1 Allow
238 FIS3000 Free Format Unit 90 mm 2 SM-25 Dots1 Dots
239 Cheque and Credit Payment Function Key 90 Inhibit 1 Allow
240 Voucher Payment Function Key0 Inhibit 1 Allow
241 PLU Code for IR POS and TMR0 6 Digits 1 7 Digits
242 Discount without Limit Function Key0 Inhibit 1 Allow
243 Concatenate Commodity Name Display 80 No 1 Yes
244 Enable PLU Price Change Flag0 No 1 Yes
245 Print Sell by Date or Used by Date when Date Equals Packed Date 90 Yes 1 No
246 Print First and Check Digits Outside Barcode 90 No 1 Yes
247 Print Packed date 90 Manual and Prepack Mode 2 Prepack Mode1 Manual 3 No Print
248 Print Sell by Date 90 Manual and Prepack Mode 2 Prepack Mode1 Manual Mode 3 No Print
249 Print Used by Date 90 Manual and Prepack Mode 2 Prepack Mode1 Manual Mode 3 No Print
250 Centering Shop Name on Label 90 No 1 Yes
251 Shop Name on Receipt 90 Top 1 Bottom
252 Auto Reconnect when Server Down0 Disable 2 Every 3 min1 Every 2 min 3 Every 15 min
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 13 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
253 Client Auto PLU Update0 Update / Delete Existing PLU 3 Update All Server PLU1 Update / Delete All Sever PLU 4 Disable2 Update Existing PLU
254 Auto Update of Client Off-line Report0 Disable 1 Enable
255 Retry Ethernet Communication0 2 times 1 5 times
256 Display Price with Tax after Clerk Key Press 80 Yes 1 No For AA only.
257 Change Place Name to PLU via Function Key0 No 1 Yes For AA only.
258 Beef Labeling 90 No 1 Yes
259 Auto Print Sub-total Label in Prepack 90 No 1 Yes
260 Beef Labeling : Print Country 90 Code 1 Name
261 External Rewinder0 Disable 1 Enable
262 Selection of Receipt / Label 80 Label 1 Receipt Always set to 1 for SM-
200.
263 FSD Net Value Minimum 80 Off 1 On For U1 only.
264 Print Ingredient Data on Next Label 90 Disable 1 Enable
265 Client Using Local Free Format Label0 No 1 Yes
266 FSD Weight 80 Back Computed (Single Range) 2 Exact Weight1 Back Computed (Dual Range)
For U1 only.
267 CPDL Language Selection 80 First Language 1 Second Language
268 Display Special Scale Message for Discounted Item0 No 1 Yes Exclude AA, HK, CN, TW
and KE.
269 Auto Clerk Accumulation (for scanner) 90 No 4 V41 V1 5 V52 V2 6 V63 V3 7 V7
For IR only.
270 Individual Report Print and Clear in Z Mode0 Disable 2 Auto Clear1 Manual Clear
271 Store Total Report Clear0 Store Total Report Only 1 All Report Effective when SPEC270
= 1 or 2.
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 14 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
272 Beef Reference Number 90 Code 1 Date
273 Item Code Follow PLU Number 90 Yes 1 No
274 Bench Key Pad 80 New 1 Old
275 Taiwan Receipt Printer 80 Disable 1 Enable For TW only.
Apply for POS1 FLEX PP2000 srs. 2 only.
276 Floating Server0 Disable 1 Enable
277 Real Time Buffer 90 No 4 5 Days1 2 Days 5 6 Days2 3 Days 6 7 Days3 4 Days 7 Unlimited
278 Traceability Report 90 Disable 3 By Date and Reference No.1 By Reference No. 4 By Date and PLU No.2 By PLU No.
279 U1 Self-service 80 Disable 1 Enable For U1 only.
280 Real Time Customer Number0 No 1 Yes
281 Real Time Buffer Receipt 80 Detail 1 Total Only
282 Barcode Function 80 Without CR 1 With CR
283 Barcode Look-up-table (LUT) Contents 80 Non-weigh Item Only 1 All Items
284 Open Cash Drawer on Credit Payment 90 Allow 1 Inhibit
285 Australia ECR Function 80 No 1 Yes For AR only.
286 Enforce Amount Tendered 90 No 1 Yes
287 Enforce Change Key 90 No 1 Yes
288 Planned Price Printed in Report0 Enable 1 Disable
289 Repeat PLU Call0 No 1 Yes
290 Payment Key 80 Disable 1 Enable For DEC countries only.
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 15 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
291 Gap Value In-feed Operation 90 Re-adjustable 1 No Change
292 SM-200 Power Save 80 Back Light Off 1 Power Off
293 SM-200 Power Save Timeout 80 3 Min 2 10 Min1 5 Min 3 2 MinPLU Scrolling Message Display Interval 90 Disable 4 1 Min For U1 only.
1 3S 5 2 Min2 10S 6 5 Min3 30S
294 SM-200 Battery Option 80 Yes 1 No
295 SM-300 Scrolling Message Update Rate 80 6 Lines 1 12 Lines
296 Ingredient File-Size Expansion 80 Maximum 99 records 1 Maximum 255 records For SF only.
297 Print PLU Ingredient in Receipt 80 No 1 Yes
298 Traceability Update Function0 No 1 Yes
299 Keyboard Selection 80 Normal Keyboard # 2 80 Preset Keys1 100 Preset Keys
# 32/56 Preset Keys.Identical to SPEC672.
300 SM-500 Self-Service 80 No 1 Yes 96 Preset Keyboard.
Identical to SPEC688.
301 Print Receipt after Accumulation 90 Yes 1 No
302 Fixed Port Number for EthernetEnter value from 1 to 254
303 DHCP IP Address Lease Time0 Disable 1 Enable
304 Server Port NumberEnter value from 1 to 254
305 Character Spreading Speed Up 80 Disable 1 Enable (S3, S4, M3 & M4)
For U1 only.
306 Unit Print on Receipt0 Pcs 1 Items
307 Code Page 80 DOS 1 ANSI For IR only.
308 SM-500 2nd
Receipt Printer 80 Disable 1 Enable
309 Praxis Function 8
0 Disable 1 Enable For DEC countries only.
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 16 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
310 Multi Barcode Type 90 EAN128 2 CODE1281 RSS
For AI 01 only.
311 Operator Logging Function0 Disable 1 Enable
312 Price Change Password 90 Disable 1 Enable For CA only.
313 Price Change Log File 90 Disable 1 Enable For CA only.
314 Training Mode 80 Disable 2 Enable (Clerk Report)1 Enable
For DEC only.
315 Print PLU Traceability in Receipt 80 Yes 1 No
316 Include Prepack Total in Manual Total Report 90 Yes 1 No
317 Wireless Communication 90 No 1 Yes
318 Wireless FTP Port NumberEnter value range from 1 to 9999 Not in used.
319 Delete Traceability Record 90 Yes 1 No
320 PLU Link to Text Field0 Disable 1 Enable
321 Julian Date for Packed and Sell Date 80 No 1 Yes For U1 only.
322 Price Printing Size (Large Font)0 No 1 Yes
323 Auto PLU Broadcasting0 Disable 1 Enable
324 Decimal Point For Unit Price And Total Price 80 Disable 1 Enable
325 Peel Sensor Value0 Re-adjust 1 No Change
326 ON/Off Key 90 Enable 1 Disable
327 SM300 Print Control 80 1 Enable
328 TU 9 Digit Total Price 80 Disable 1 Enable For Tu only.
329 PLU Tare Call up 80 Allow 1 Inhibit
330 Individual Scale Store Total Report 80 No 1 Yes
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 20 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
331 Default ITF for Barcode 90 Disable 1 Enable
332 ITEM Text (5-16) Print on Total Label 90 Disable 1 Enable
333 Image at Top ReceiptEnter range from 0 to 99
334 Image at Bottom ReceiptEnter range from 0 to 99
335 Traceability Eat By Date0 Disable 1 Enable
336 Traceability Max Weight0 Disable 1 Enable
337 Traceability Default Label Format0 Not Used 5 F51 F1 6 F62 F2 7 F73 F3 8 F84 F4
338 Traceability Barcode0 EAN13 1 EAN128
339 Flag Data (EAN13)Enter range from 0 to 99
340 Enforce Scan0 No 1 Yes
341 TVP2000 (SM300)0 Not Send T10 1 Send T10 Label Format
342 LCD 1 Line Scroll0 Disable 1 Enable
343 Clear Key in Prepack0 Enable 1 Disable
344 Print Pack Date0 Yes 1 No
345 Update Spec For Server/Client System0 Enable 1 Disable
346 Update Label Turn-over In Receipt Buffer0 No 2 Only In Prepack Mode1 Only In Registration Mode 3 Both
347 Internet Broadcast0 No 1 Yes
348 Taiwan POP Label0 Disable 1 Enable For TW only
349 Direct Access To Clerk Mode0 Disable 1 Enable
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 21 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
350 Additional Rounding In Receipt0 Print 1 No Print
351 Gratuitous ARP0 Disable 1 Enable
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 22 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
400 Auto Power-Off Function 90 Inhibit 3 30 Minutes1 3 Minutes 4 1 Hour2 10 Minutes 5 3 Hours
401 RTS/CTS Handshaking of RS-232C 90 On 1 Off
402 Reset Receipt consecutive Number after Reset Report 90 No 1 Yes
403 Vender Number Display in Registration Mode 90 Allow 1 Inhibit
404 Number of Vender Keys 90 4 Vender Keys 2 6 Vender Keys1 5 Vender Keys 3 7 Vender Keys
405 Priority of Shop Name and Special Message on Receipt 90 Shop Name Priority 1 Special Message Priority
406 Centering of shop name on Receipt 90 Allow 1 Inhibit
407 Centering of special Message on Receipt 90 Allow 1 Inhibit
408 One or Two Touch for Receipt Printing in AMT/TEND 90 One Touch 1 Two Touch
409 PLU Number Printing on Receipt 90 Inhibit 1 Allow
410 Sale Item Entry Method 90 Total 1 Item
411 Default Vender Transaction by Print Key 90 Allow 1 Inhibit
412 Print Checking Line 90 Print 1 No Print
413 Source of Used by Date 90 Current Date 1 Packed Date
414 In-Store Barcode for Barcode Scanner Enter 90 F1F2 CCCCCC TTTT CD 5 F1F2 CCCCC XCD TTTT CD1 F1F2 CCCCC TTTTT CD 6 F1F2 CCCC XCD TTTTT CD2 F1F2 CCCC TTTTTT CD 7 F1F2 CCCCC PCD TTTT CD3 F1F2 CCC TTTTTTT CD 8 F1F2 CCCCC 0 TTTT CD4 F1F2 CC TTTTTTTT CD
#1: F1F2 - 20~29#2: CC ~ CCCCCC -
Item code.#3: TTTT ~ TTTTTTTT
Total Price
415 Non-PLU Item Enter by Barcode Scanner 90 Allow 1 Inhibit
416 Barcode Scanner 90 Allow 1 Inhibit
417 Centering of Commodity Name on Label 90 Allow 1 Inhibit
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 23 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
418 Weight Data Synchronization Function 90 Allow 1 Inhibit
419 Open Cash Drawer when Issue Label 90 Allow 1 Inhibit
420 Print Grand Total on Sales Report 90 Allow 1 Inhibit
421 Constitution of Report 90 Receipt Data 2 Receipt Data & Label Data1 Label Data
422 Currency Symbol for Total Amount on Receipt 90 No Print 2 Suffixation1 Prefixion
423 Print Total Number of Pieces on Receipt 90 Allow 1 Inhibit
424 Total Barcode on Receipt for Total Price in 2nd
Currency 90 Allow 1 Inhibit For FR only.
425 Second Currency as Reference Price 90 No 2 For Label1 For Receipt 3 For Receipt and Label
426 Print Tare Weight when Unit Price is 0 90 Allow 1 Inhibit
427 Eliminate Cash Line on Receipt when No change Operation 90 Allow 1 Inhibit
428 PRINT Tax List on Receipt 90 Allow 1 Inhibit Effective when SPEC603
= 1
429 Non-Weigh PLU Unit Price Display 90 Total Price Column 1 Unit Price Column
430 Items on PLU / Main Group / Dept / Tax Report 90 Registered Items 1 All Items
431 Eliminate Vender Data on Sales Report 90 Allow 1 Inhibit
432 Font Size for Commodity Name on Receipt 90 Standard Font Size 2 Largest Font Size1 Larger Font Size
433 Condition of Additional Price Rounding for Total Price 90 Cash Payment Only 1 Always
434 Item Barcode Type 90 EAN Type 2 User Programmable1 ITF Type
435 Total Barcode Type 90 EAN Type 1 ITF Type
436 In-Store Barcode Type for Barcode Scanner Enter 90 EAN Type 1 ITF Type
437 Print Rounding on Receipt 90 Allow 1 Inhibit
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 24 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
438 Print Sub-Total on Receipt 90 Allow 1 Inhibit
439 Pulse width for Opening Cash Drawer 90 20ms (Default Value) 3 200ms1 50ms 4 300ms2 100ms 5 400ms
440 R Mode Password Function 90 Inhibit 2 Power On & Password R Key1 Password R Key
441 Set / Reset Auto PLU Call Function Key Enable 90 Allow 1 Inhibit
442 Change Main Group Code for Auto Plu Call Function Key Enable 90 Allow 1 Inhibit
443 Prefix Fixed Code to PLU Code for Auto PLU Calling 90 No 2 2 Digits1 1 Digit 3 3 Digits
Effective when Spec39 =1, Spec40 = 0
444 Decimal Point Position for Second Currency 90 None 2 0.001 0.0 3 0.000
445 Unit Price Change for PLU after Label Printing 90 Inhibit 1 Allow
446 Print Tare Weight on Receipt0 Allow 1 Inhibit
447 Place Change for PLU after Label Printing 90 Inhibit 1 Allow For KE only.
448 Sell Date Change for PLU after Label Printing 90 Inhibit 1 Allow For KE only.
449 Trace Auto Clear0 Inhibit 1 Allow For KE only.
450 Trace per PLU0 Inhibit 1 Allow For KE only.
451 Trace Auto Update0 Inhibit 1 Allow For KE only. Effective
when Spec450 = 1.
452 Trace Confirm0 Inhibit 1 Allow For KE only.
453 Trace C/D Check0 Inhibit 1 Allow For KE only.
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 25 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
454 Forced Tare when Tare Value in PLU is 9999 90 Inhibit 1 Allow For CA only.
455 Printing of Servings Fact 90 SS Top & SC Bottom 2 SS Print Only1 SS Bottom & SC Top 3 SC Print only
For CA only.
456 Special ‘FOR’ operation 90 Inhibit 1 Allow For U1 only.
457 CN Weight Trace function 90 Inhibit 1 Allow For CN only.
458 CN Weight Quota function 90 Inhibit 1 Allow For CN only.
459 Symbol Format for Date Print 90 Dash 1 Period
460 CN Weight Trace Password 90 Inhibit 1 Allow For CN only.
461 Unit and Currency Symbol for each line in Receipt 90 Inhibit 1 Allow For U1 only.
462 1000 Separator for total line print on receipt 90 Inhibit 1 Allow For IN only.
463 Print SHAMSI date 90 Inhibit 1 Allow For IN only.
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 26 of 32
Specification List SM-100 V2.00 26 December, 2006
[REZERO] + [1][4][2] WEIGHT AND MEASUREMENT SPECIFICATION(Span Switch must be ENABLE when accessing this mode.)
SPECNO.
SPECIFICATION DESCRIPTION SM-100
600 Price Base for Price Calculation for Weighed Items 90 100 g Base 2 1 lb Base1 1 kg Base
601 Auto Zero Function 90 Enable 1 Disable
602 Display Type 80 Single Display 1 Three Display
603 Tax 90 No Tax 1 Tax
604 Minus Weight Masking 90 Minus Gross > 9e 1 Minus Gross Weight Mask
605 Manual Scale Start 80 Auto Start 1 Manual Start
606 Zero Lamp Lighting Position 80 Gross Zero +/- ¼d 1 Net Zero +/- ¼d
607 Decimal Point Position for Weight 90 None 2 0.001 0.0 3 0.000
608 Zero Point Setting Range when A/C Display Switch On 90 +/- 10% of Capacity 2 +/- 3% of Capacity1 +/- 5% of Capacity 3 +/- 2% of Capacity
609 Decimal Point for Unit Price and Total Price 90 None 2 0.001 0.0 3 0.000
610 Unit Price Decimal Right Shift 80 Inhibit 1 Allow
611 Unit Price Decimal Left Shift 80 Inhibit 1 Allow
612 Switching of Price Base 90 Inhibit 2 500 g / 1 kg1 100 g / 1 kg
613 Exit from Accumulation Mode after within Specified Interval 90 Inhibit 2 5 Sec1 15 Sec 3 10 Sec
614 Zero Setting Range when Weight Reset Switch is On or Zero Tracking 80 +/- 10% of Capacity 2 +/- 2% of Capacity
(Power on Start Point +/- 6000 IR) (Power on Start Point +/- 1200 IR)
1 +/- 5% of Capacity 3 +/- 0.6% of Capacity(Power on Start Point +/- 3000 IR) (Power on Start Point +/- 360 IR)
615 Minimum Display 90 1 2 51 2 3 10
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 27 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
616 Selection of Resolution 90 1/3000 2 1/75001 1/6000
617 New A/D 80 No 1 Yes
618 Weight Single Interval or Multi-Interval 90 Single Interval 1 Multi-Interval
619 PLU Weight Item Commodity Name Display 80 Full Display 2 No Display1 Half Display
For EB and EP type.
620 Tare Accumulation 90 Allow 1 Inhibit Effective when SPEC632
= 0.
621 Tare Subtraction 90 Allow 1 Inhibit Effective when SPEC632
= 0.
622 Manual Clear of Tare 90 Allow 1 Inhibit
623 Weight Reset Operation during Tare 90 Allow 1 Inhibit
624 Zero Tracking during Tare 90 Allow 1 Inhibit
625 Accumulation when Tare 90 Allow 1 Inhibit
626 Digit Tare 90 Allow 1 Inhibit
627 Decimal Point Figure 90 Period 1 Comma
628 Price Rounding Method for Decimal Digits on Weighed Item 90 Rounding 2 Cut Up1 Truncating
629 Additional Price Rounding Method for Item Price 90 No Addition Rounding 4 Rounding for 1
st Digit
1 ¼ Rounding (25 step) 5 Truncate 1st
Digit2 Special Rounding (5 step) 6 Cut Up 1
st Digit
3 5 Floor Rounding (0~4: 0, 5~9: 5)
630 Selection of Auto Clear of Unit Price 90 Inhibit 1 Allow
631 Selection of Maximum Capacity 80 Capacity +1d 1 Capacity +9d
632 Selection of Tare Value Exchange 80 Allow 1 Inhibit Related to SPEC620 and
621.
633 Auto Clear of Tare 90 Inhibit 1 Allow
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 28 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
634 Auto Tare Clear when Rezero 90 Inhibit 1 Allow Effective when SPEC623
= 0.
635 Trigger Point of Tare / Unit Price Auto Clear 90 Over Net 5d and Gross 21d and 1 >= Net 1d and Price > 0 and Weight
Weight Stability StabilityEffective when SPEC633= 1.
636 Auto Zero Reset 80 Inhibit 1 Allow
637 Negative Weight Tare Clear 80 Allow 1 Inhibit Effective when SPEC622
= 0.
638 Tare Range 80 < 50% of Capacity 2 Maximum 200 g1 < 5% of Capacity 3 Not Used
639 Exit From Accumulation Mode when Weight Change 90 Inhibit 1 Allow
640 Price Accumulation with Weight Change More than +/- 10d 90 Inhibit 1 Allow
641 Accumulation Available Only after Scale Shows Weight is Equal Zero 90 Inhibit 1 Allow Effective when SPEC640
= 0.
642 Tare Display for One Touch Tare 80 Allow 1 Inhibit
643 Weight Range for Non-weigh Item 90 Only Net 0d 1 Always
644 Weight Stability Condition 90 Loose 2 Tight1 Normal 3 Stringent
645 Weight Range for R Mode Printing 90 Over Net 5d and Over Gross 21d 2 Over Net 19d and Weight Stability
and Weight Stability1 Over Net 1d and Weight Stability 3 Over Net 20d and Weight Stability
646 Weight Range for Prepack 90 Over Net 5d and Over Gross 21d 2 Over Net 19d and Weight Stability
and Weight Stability1 Over Net 1d and Weight Stability 3 Over Net 20d and Weight Stability
647 PLU Tare 90 Allow 1 Inhibit
648 Item Print when Tare 90 Allow 1 Inhibit
649 Tax Rounding Method 80 Rounding 1 Truncation
650 Checking Span Switch for Internal Count 90 No 1 Yes
651 Certain Function Key Order 80 Function Key Precede Numeric Key 1 Numeric Key Precede Function Key
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 29 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
652 Angle Rotation for Certain Items Printing 90 Anti-clockwise 1 Clockwise
653 Total Price Discount 90 Allow 1 Inhibit
654 Packed Date Function in Manual Mode 90 Inhibit 1 Allow
655 Prepack Mode 90 Allow 1 Inhibit Always set to 1 for SM-
200.
656 Scale Type 90 Pole 5 Cassette-B1 Bench 6 Cassette-P2 Elevated 7 B-CS3 Hanging 8 P-CS4 Self-service
Always set to 0 for SM-200.
657 Password Setting 90 Allow 1 Inhibit By-pass Span Switch.
658 Extra Label for Prepack Printing 80 Inhibit 1 Allow
659 Item Price Printing 80 Item Price before Tax 1 Item Price after Tax
660 Barcode Check Line 90 Print 1 No Print
661 Additional Price Rounding Method for Total Price 90 No Addition Rounding 4 Rounding for 1
st Digit
1 ¼ Rounding (25 step) 5 Truncate 1st
Digit2 Special Rounding (5 step) 6 Cut Up 1
st Digit
3 5 Floor Rounding (0~4: 0, 5~9: 5)
662 Unit Price Recalculation 80 Inhibit 1 Allow
663 Nordic Country 80 Inhibit 1 Allow
664 Self-service Type 90 Inhibit 1 Allow Related SPECs are 126,
136, 672.
665 Swap of Unit Price and Total Price Display in R Mode 80 Inhibit 1 Allow
666 Multiplication Operation in Prepack Mode 90 Inhibit 1 Allow
667 Dot Matrix Display Scanning Rate 80 Normal 2 High1 Slow 3 Very HighR Mode Display Configuration 80 Standard 2 Not Used1 Without Tare Weight 3 Not Used
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 30 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
668 Commodity Name Display Interval 90 0.5 Sec 2 1.5 Sec #1 1.0 Sec 3 2.0 Sec #
For EB and EP type.# Effective whenSPEC619 = 0.
16 x 16 Commodity Name Display 80 1.0 Sec 2 2.0 Sec1 1.5 Sec 3 2.5 Sec
For CN, HK, MS and TW.
669 Mask Weight Display 80 No 1 Yes
670 Scroll Message Display 80 Full Length 1 Half Length For EB and EP type.
671 Display CPU Selection 80 Below Version 0.16 1 Version 0.16 and Above
672 Keyboard Selection 80 Normal Keyboard # 2 80 Preset Keys1 100 Preset Keys
# 32/56 Preset Keys.
673 Hanging Scale 80 No 1 Yes
674 Masking Last Digit Over 15 lb 80 No 1 Yes
675 Auto Zero Adjustment Range 80 +/- 5d 1 2% of Capacity Effective when SPEC636
= 1.
676 Right Side Barcode Data Shifting for Item and Total Barcode 90 No 3 Left Shift Twice1 Right Shift Once 4 Left Shift 3 Times2 Right Shift Twice 5 Left Shift Once
(left shift valid forquantity only)
677 Manual Weight Function Key 90 Disable 1 Enable
678 Printing of Item Label after Weight Change 80 Inhibit 1 Allow For SS type.
Effective when SPEC640 and 641 = 1.
679 Catty (Kati) and Tael 80 Disable 1 Enable Available in special
version only.
680 Tare Clear when Exit From Z mode, Password Mode, Changing of Customer, andWeight and Measure Specification
8
0 No 1 Yes
681 Euro Second Price Rounding Method 90 Rounding 2 Cut Up1 Truncating
682 Additional Euro Second Price Rounding Method 90 No Addition Rounding 4 Rounding for 1
st Digit
1 ¼ Rounding (25 step) 5 Truncate 1st
Digit2 Special Rounding (5 step) 6 Cut Up 1
st Digit
3 5 Floor Rounding (0~4: 0, 5~9: 5)
683 Foreign Code for Standard Countries 80 Inhibit 2 Korean Code1 GB Code
Not effective for AA, CN,HK, KE, MS and TW.
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 31 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
684 Calibration at 1/5 of the Capacity 80 Disable 1 Enable Not effective when
SPEC615 = 0.
685 Auto Selection Between Two Label Format 80 Inhibit 1 Allow
686 Rounding for Weight 90 No 1 Yes
687 Proportional Tare 90 No 1 Yes
688 SM-500 Self-service 80 No 1 Yes
689 Consecutive Display 80 1 Sec Stop 2 4 Sec Stop1 2 Sec Stop 3 6 Sec Stop
690 Test Program 80 Disable 1 Enable
691 One Touch Tare 80 Enable 1 Disable
692 RESERVED 8
693 Flexi Self-Service Key Grouping 90 No 1 Yes
694 Weight Hold Function 80 Disable 1 Enable
695 Clerk Password Setting 90 Disable 1 Enable For CA only.
696 Quantity Symbol Re-calculation 80 No 1 Yes
697 RESERVED 8
698 DEC PLU Tare 80 No 1 Yes
699 Right side Data of Barcode Shift 90 Normal 2 Weight1 Quantity 3 Price
2nd
R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 32 of 32
Specification List SM-100 V2.00 26 December, 2006
SPECNO.
SPECIFICATION DESCRIPTION SM-100
700 Version Display When Power On 90 Allow 1 Inhibit
701 Re-Zero Function 90 Allow 1 Inhibit
702 Total Price Display 90 Allow 1 Inhibit
703 Tax Rounding Method for Tax Value Excluded in Price 90 Rounding 2 Cut Up1 Truncation
704 Tax Rounding Method for Tax Value Included in Price 90 Rounding 2 Cut Up1 Truncation
705 Commodity Name Display When Call PLU in Label Mode 90 Allow 1 Inhibit
706 Commodity Name Display When Call PLU in Receipt Mode 90 Allow 1 Inhibit
707 Price Fix 90 Inhibit 2 Via FIX Key1 Allow
708 Tare Fix 90 Inhibit 2 Via FIX Key1 Allow
709 Printing of Item Label Condition in Prepack Mode 90 Weight Change (More than +/-10e) 1 Remove Weight
710 Net / Gross Multi-interval 90 Gross Multi-interval 1 Net Multi-interval
711 Priority of Tare Operation0 One Touch Tare Priority 1 Digit Tare Priority
712 Receipt mode 90 Allow 1 Inhibit
SM-100 Flexible Barcode Setting Guide
OperationDisplay
Remarktare weight Unit price/kg price
Press [mode] third
timesS1 -- --> PLU FILE Enter programmer.
Press numeric 4 and 6 S46 -- --> FLEXI BARCODEEnter Flexible Barcode
programme.
Press [*] S46.0 F BAR 0 NO SET Program Flexible Barcode.
Enter numeric 1 S46.0 F BAR 1 NO SET Program Flexible Barcode 1.
Press [*] S46.1 F BAR 0 FLAG
Program Flag Code.(0 for F2,1
for F1F2,2 for non.)
Press [*] S46.2 F BAR 0 ITEM CODE Enter item code length.
Press [*] S46.3 F BAR 0 DATA1
Enter data format for DATA1.( 0
for weight,1 for quantity,2 for unit
price.3 for weight/quantity,4 for
total price,5 for original price,6 for
user programmable.)
Press [*] S46.4 F BAR 0 DIGIT Enter DATA1 length.
Press [*] S46.5 F BAR 0 SHIFT
Shift for DATA1.( 0 for no right
shift,1 for right shift, 2 for right
shift x2, 3 for left shift, 4 for left
shift x2, 5 for left shift x3.)
Press [*] S46.6 F BAR 0 DATA2
Enter data format for DATA2.( 0
for weight,1 for quantity,2 for unit
price.3 for weight/quantity,4 for
total price,5 for original price,6 for
user programmable.)
OperationDisplay
Remarktare weight Unit price/kg price
Press [*] S46.7 F BAR 0 DIGIT Enter DATA2 length.
Press [*] S46.8 F BAR 0 SHIFT
Shift for DATA2.( 0 for no right
shift,1 for right shift, 2 for right
shift x2, 3 for left shift, 4 for left
shift x2, 5 for left shift x3.)
Press [*] S46.9 F BAR NO MIDDLE CD
Press [ⅹ] to select the
middle check digit.
Press [*] S46.1 F BAR NO LAST CD
Press [ⅹ] to select the last
check digit.
Press [*] S46.1 F BAR ITF BARCODE
Press [ⅹ] to swith ITF and EAN
barcode.
Press [#] S46 -- --> FLEXI BARCODE Save the flexible barcode 1.
Note: See the Flexible Barcode Usage Note at 《3.6.1 PLU programming》 in SM-100 Operation
manual.
SM-100 Traceability Setting Guide
Prepare
¾ Set SPEC258 to “1”
Traceability Programming
OperationDisplay
Remarktare weight Unit price/kg price
[Mode] [Mode] [Mode] S1 Æ PLU FILE Enter S mode
[3] [4] S34 Æ COUNTRY FILE Enter country file programming
[*] [1] S34.0 1 NO SET Program country No. 1
[*][C][H][I][N][A] S34.1 COUN CHINA Name 5 Program country name “CHINA”
[#] S34 Æ COUNTRY FILE Save Country No. 1
[3] [5] S35 Æ CUTTING HALL Enter cutting hall programming
[*] [1] S35.0 HALL 1 NO SET Program cutting hall No. 1
[*][1] S35.1 HALL 1 COUNTRY Program cutting hall country No. 1
[*][C][U][T] S35.2 HALL CUT Name 3 Program cutting hall name “CUT”
[#] S35 Æ CUTTING HALL Save cutting hall No. 1
OperationDisplay
Remarktare weight Unit price/kg price
[3][6] S36 Æ SLAUGHTER HOUSEEnter slaughter house
programming
[*][1] S36.0 HOUSE 1 NO SET Program slaughter house No. 1
[*][1] S36.1 HOUSE 1 COUNTRYProgram slaughter house country
No.1
[*][S][L][A][U][G] S36.2 HOUSE SLAUG NAME 5Program slaughter house name
“SLAUG”
[#] S36 Æ SLAUGHTER HOUSE Save slaughter house No. 1
[4][7] S47 Æ KIND FLIE Enter kind file programming
[*][1] S47.0 KIND 1 NO SET Program kind file No. 1
[*][M][E][A][T] S47.1 KIND MEAT NAME 4 Program kind name “MEAT”
[#] S47 Æ KIND FILE Save kind file No. 1
[4][8] S48 Æ CATEGORY FILE Enter category file programming
[*][1] S48.0 CATEG 1 NO SET Program category No. 1
[*][B][E][E][F] S48.1 CATEG BEEF NAME 4 Program category name “BEEF”
[#] S48 Æ CATEGORY FILE Save category file No. 1
OperationDisplay
Remarktare weight Unit price/kg price
[4][9] S49 Æ BREED FILE Enter breed file programming
[*][1] S49.0 BREED 1 NO SET Program breed file No. 1
[*][B][U][L][L] S49.1 BREED BULL NAME 4 Program breed name “BULL”
[#] S49 Æ BREED FILE Save breed file No. 1
[3][7] S37 Æ TRACEABILITY Enter traceability programming
[*][1] S37.0 TRACE 1 NO SET Program traceability No. 1
[*][1] S37.1 TRACE 1 BORN Choose born country No. 1
[*][1] S37.2 TRACE 1 FATTEN Choose fatten country No. 1
[*][1] S 37.3 TRACE 1 S HOUSE Choose slaughter house No. 1
[*][1] S37.4 S CNT 1 LNK 1Choose link country No. 1 for
slaughter house
[*][1] S37.5 TRACE 1 C HALL Choose cutting house No. 1
[*][1] S37.6 C CNT 1 LNK 1Choose link country No. 1 for
cutting hall
[*][1] S37.7 TRACE 1 ORIGIN Choose original country No. 1
OperationDisplay
Remarktare weight Unit price/kg price
[*][R][C][D] S37.8 R-CD RCD NAME 3 Program R-CD content “RCD”
[*][G][T][I][N] S37.9 GTIN GTIN NAME 4 Program GTIN content “GTIN”
[*][L][O][T] S37.10 LOT LOT NAME 3 Program LOT content “LOT”
[*][1] S37.11 TRACE 1 KIND Choose kind No. 1
[*][1] S37.12 TRACE 1 CATEG Choose category No. 1
[*][1] S37.13 TRACE 1 BREED Choose breed No. 1
[*][C][O][N][T] S37.14 CONT CONT NAME 4 Program cont content “CONT”
[*][0][6][0][3][1][0] S37.15 TRACE 060310 EAT D Program eat by date “06/03/10”
[*][5][0][0][0] S37.16 TRACE 5.000 WEGHT Program maximum weight “5kg”
[*][S][C][D] S37.17 S CD SCD NAME 3 Program S CD content “SCD”
[*][S][N][M] S37.18 S NM SNM NAME 3 Program S NM content “SNM”
[*][S][A][D][1] S37.19 S AD1 SAD1 NAME 4 Program S AD1 content “SAD1”
[*][S][A][D][2] S37.20 S AD2 SAD2 NAME 4 Program S AD2 content “SAD2”
[#] S37 Æ TRACEABILITY Save traceability No. 1
Free Format Programming
¾ Enter “S12 Æ FREE FORMAT”, press [*]
¾ Edit the correlative items for traceability in free format
PLU ITEM Programming
¾ Enter “S19 Æ PLU ITEM”, press [*]
¾ Set “ Item TRACE” to “PROGRAM” and press [#] to save
PLU Programming
¾ When you edit PLU, set “S1.64 PLU” to “TRACE ALLOW” and press [*]
¾ Input traceability number and press [#] to save
¾ In the end, when you call the PLU and print label, you’ll see the traceability
information on the label
SM-100 Nutrition Fact Setting Guide
Concept
Nutrition uses fix template to print. Totally It has 12 fix templates(No. 70 ~ No. 81).
Setting Method
1. Enter S mode
2. Enter “S19 --- PLU ITEM” and set “IMAGE” and “NUTRI” to “PROGRAM”
3. Enter “S12 --- FREE FORMAT”
4. Enter “S12.5 IMG 1 Å 47 F ITEM” to “S12.5 IMG 10 Å 56 F ITEM” to set the print
area of Nutrition. (In each label format, totally you can print 10 images)
5. Enter “S1 --- PLU FILE” to create PLU.
6. Enter “S1.50 PLU 0 IMAGE 1” to choose the template number for IMAGE 1
(From No. 70~ No. 81).
…
7. Enter “S1.59 PLU 0 IMAGE 10” to choose the template number for IMAGE 10
(From No. 70~ NO. 81).
8. Set “S1.81 PLU PRINT NUTRI” to set nutrition print status to “Print”.
9. Enter from S1.82 to S1.10 to input nutrition contents.
10. For extra details on the Nutrition Fact, Enter S11: TXT form to edit by hands.
11. Enter “S12 --- FREE FORMAT” to set up the TXT position.
12. Press [PLU] key to save.
PCFL-1 Operation GuideShanghai TERAOKA Electronic Co., Ltd. --- Technical Support
Dept.Tel: +86-21-6408-5151 Fax: +86-21-6408-3468
Note: this guide is available just for SM series expect the SM-100.
一、 The link of the hardware
Link the PC with scale via RS232C.
二、 Operation
1. The Spec setting in the scale
3 for SPEC51 (The SIO baud rate is 9600. )
1 for SPEC52 (The SIO data length is 8.)
0 for SPEC53 (No SIO parity digit.)
0 for SPEC54 (1 bit stop bit.)
2 for SPEC60 (SIO work via PCFL-1)
2. The setting in the software
1) open the software
PCFL-1 Operation GuideShanghai TERAOKA Electronic Co., Ltd. --- Technical Support
Dept.Tel: +86-21-6408-5151 Fax: +86-21-6408-3468
2) the com port setting
Please note:
a) The com port should be the same as the one used in your
computer.
b) The com port setting must be same as setting in the scale.
3) the folder for save
PCFL-1 Operation GuideShanghai TERAOKA Electronic Co., Ltd. --- Technical Support
Dept.Tel: +86-21-6408-5151 Fax: +86-21-6408-3468
Note: You could set the default folder for save the data received from the scale.
3. Operation
1) receive the data from the scale
PCFL-1 Operation GuideShanghai TERAOKA Electronic Co., Ltd. --- Technical Support
Dept.Tel: +86-21-6408-5151 Fax: +86-21-6408-3468
Note: You could press the key to receive the data from scale.
2) send the data to scale
Note: You could press the key to send the data to scale.
2) the operation in the scale
OperationDisplay Remark
Weight Unit price Price Z
[M][0][M][M] DAILY 0 CLR X Enter the [Z] mode
[zero]+[0][1][0] BAC PLU FILE X Press preset key [7]or [8] to select
the transmit item: PLU, Format,
Others or All.
Preset key [8] BAC FOR FILE X
Preset key [8] BAC OTH FILE X
Preset key [8] BAC ALL FILE X
PCFL-1 Operation GuideShanghai TERAOKA Electronic Co., Ltd. --- Technical Support
Dept.Tel: +86-21-6408-5151 Fax: +86-21-6408-3468
[*] BAC SA TO FL-1 X Press preset key [7]or [8] to select
the transmit method: save data to
FL-1,read data from FL-1,verify
data with FL-1.
Preset key [8] BAC RD FR FL-1 X
Preset key [8] BAC COMP FL-1 X
[*] T-OUT OPN GOOD X Transmit successfully.
[Tare] DAILY 0 CLR X Back to Z mode.
Jasonzhou,
Shanghai Teraoka Electronic Co.,Ltd
Technical Service Dept.
Dec. 7th ,2005
SM100 ERROR MESSAGE
9. SM100 ERROR MESSAGE
ERROR MESSAGE
The machine beeps and following error messages appear on display, if incorrect operation is performed.
No. Error Message Causes
1 PAPER ENDLabel sensor sense no label. No more labels. Replace
label roll
2 FEED PAPER FIRST Label miss feed, press FEED key to align label.
3 PEEL LABEL Peel sensor activated, remove label away from sensor.
4 CHANGE PAPER Change paper mode between label and receipt.
6 NON PRINT No manual printing.
7 UNIT PRICE OVERFLOW Please check unit price.
9 NON LABELNo free format is programs. Set a free format or use
standard format.
12 MEMO NOT INITIALIZED Memory problem. Please clear the memory.
14 HEAD IS NOT CLOSED Thermal head no closed. Please close thermal head.
16 FILE MEMORY FULLNot enough memory. Expand memory or delete
unnecessary data.
18 PLEASE REMOVE WEIGHT Fixed price item, please remove weigh.
19 PLU NOT EXIST No such PLU data or number exists.
20 TOTAL PRICE IS 0No total price for item. Unit price, weight or quantity is
0.
24 WEIGHT OF Weight over maximum capacity when print.
26 TOTAL PRICE OVERFLOW Total price over the limit to display or print.
29 PLEASE SET TARE VALUE When force tare is enable, a tare weight must be entered.
39 PLEASE PRESS PLU KEY Press PLU(#) key. To save data in some procedure.
44 KEY ALREADY ASSIGNED Preset key already been assigned with function or PLU.
48 PLU DATA INVALID U1 only. Quantity setting incorrect when using FOR.
49 QTY OF Quantity data over the limit.
54 BELOW MIN WEIGHT Weight is below min weight set when printing.
57 PRICE ACC OF Accumulated quantity over the limit.
59 PLEASE SEE LABEL QTY Set print label quantity when the function is use.
61 GRAND TOTAL OF Grand total price over the limit.
71 PRINT INHIBITED Cannot print weigh item at Prepack mode.
74 SELF SERVICE MODE Can only use Self-service procedure only.
95 CAL00 ERROR Zero point calibration error.
96 CALSP ERROR Full scale point Calibration error.
97 FORMAT ERROR No free format is program.
98 NO DATA IN REPORT There is no data in report when printing report.
99 EXCEED WEIGHT QUOTA CN only. Please reset weight quota.
SM100 ERROR MESSAGE
FATAL MESSAGE
No. Fatal Error Message
F002 External flash memory erase error
F003 External flash memory program error
F004 External flash memory program error
F005 Internal RAM read/write error
F006 External RAM read/write error
F007 External ethernet IC read/write error