4
SERVICES PARTS SERVICES PARTS -1- BARDON INSTALLATION INSTRUCTIONS TOP INLET AND REAR INLET URINAL K-4960T-ET/K-4960T-ER(3L) K-4960T-WET/K-4960T-WER(1L) · · · Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. Follow the sections that pertain to your particular installation. This will help you avoid costly mistakes. In addition to proper installation, read all operating and safety instructions. All information in these instructions is based upon the latest product information available at the time of publication. Kohler China reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. These instructions contain important care, cleaning, and warranty information - . please leave instructions for the consumer · · · - 1. ........................................................ 2. .............................................. 3. 4. ........................................................................ 5. ................................................ 6. 7. 18376 Urinal Spud Assy. 52046 Hanger Accessory Pack 53405 .............................................................Collar, Female 53410 Washer 85061 Beehive Strainer Assy. 1018203 ..........................................................Slip Nut Assy. 51543-BC..................................................................Washer 8. 53407-BC ....................................................................Screw 1. 2. 3. 4. 5. 18376..........................................................3/4 52046 ...................................................................... 53405 ...................................................................... 53410 ............................................................................. 85061 ...................................................................... 6. 1018203........................................................... 7. 51543-BC....................................................................... 8. 53407-BC....................................................................... ROUGHING-IN * Fixture dimensions are nominal and conform to tolerances by ASME Standard A112.19.2-2003. * ASME (A112.19.2-2003). K-4960T-ET/K-4960T-WET 3/4" SPUD 523mm 520mm 2" N.P.S. TAP *600mm 77mm 715mm 486mm 360mm 305mm 475mm 1019mm TO FLOOR 3/4" SPUD 2" N.P.S. TAP 523mm *600mm 77mm 77mm 715mm 486mm 360mm 305mm 475mm 1019mm TO FLOOR K-4960T-ER/K-4960T-WER ã ã , 2008 Copyright Kohler China Ltd., 2008 528137 1037283-T01-B

BARDON - KOHLER · bardon installation instructions top inletand rear inlet urinal k-4960t-et/k-4960t-er(3l) ... k-4960t-wet/k-4960t-wer(1l) top inletand rear inlet urinal 1037283-t01-b

Embed Size (px)

Citation preview

Page 1: BARDON - KOHLER · bardon installation instructions top inletand rear inlet urinal k-4960t-et/k-4960t-er(3l) ... k-4960t-wet/k-4960t-wer(1l) top inletand rear inlet urinal 1037283-t01-b

SERVICES PARTSSERVICES PARTS

-1-

BARDON

INSTALLATION INSTRUCTIONS

TOP INLET AND REAR INLET URINAL

K-4960T-ET/K-4960T-ER(3L)

K-4960T-WET/K-4960T-WER(1L)

Please read these instructions carefully to familiarizeyourself with the required tools, materials, and installationsequences. Follow the sections that pertain to yourparticular installation. This will help you avoid costlymistakes. In addition to proper installation, read alloperating and safety instructions.All information in these instructions is based upon thelatest product information available at the time ofpublication. Kohler China reserves the right to makechanges in product characteristics, packaging, oravailability at any time without notice.These instructions contain important care, cleaning, andwarranty information -

.please leave instructions for the

consumer

� -

1. ........................................................

2. ..............................................

3.

4. ........................................................................

5. ................................................

6.

7.

18376 Urinal Spud Assy.

52046 Hanger Accessory Pack

53405.............................................................Collar, Female

53410 Washer

85061 Beehive Strainer Assy.

1018203 ..........................................................Slip Nut Assy.

51543-BC..................................................................Washer

8. 53407-BC....................................................................Screw

1.

2.

3.

4.

5.

18376..........................................................3/4

52046......................................................................

53405......................................................................

53410.............................................................................

85061......................................................................

6. 1018203...........................................................

7. 51543-BC.......................................................................

8. 53407-BC.......................................................................

ROUGHING-IN

* Fixture dimensions are nominal and conform to tolerances

by ASME Standard A112.19.2-2003.* ASME

(A112.19.2-2003).

K-4960T-ET/K-4960T-WET

3/4" SPUD

523mm

520mm

2" N.P.S.TAP

*600mm

77mm

715mm

486mm360mm

305mm

475mm

1019mmTO FLOOR

3/4" SPUD

2" N.P.S.TAP

523mm *600mm

77mm

77mm

715mm486mm360mm

305mm

475mm

1019mmTO FLOOR

K-4960T-ER/K-4960T-WER

, 2008

Copyright Kohler China Ltd., 2008

528137

1037283-T01-B

Page 2: BARDON - KOHLER · bardon installation instructions top inletand rear inlet urinal k-4960t-et/k-4960t-er(3l) ... k-4960t-wet/k-4960t-wer(1l) top inletand rear inlet urinal 1037283-t01-b

1. 523mm 2 NPS13mm

2. 1019mm

3. ( )12mm

4. ()

5.

6.

7.

8.

"

Refer to the roughing-in drawing for proper heights ofsupply and waste locations. Install supply piping andwaste piping in accordance with local plumbing codes.

Refer OUTLET DETAILS.

NOTE:

1. Measure from floor to centerline of waste outlet 523mmhigh and anchor waste pipe with 2" NPS male nippleprotruding approximate 13mm past the finished wall.

2. Measure from floor to centerline of hanger brackets1019mm and anchor hangers securely to the wall.

3. Screw the waste fitting (supplied with urinal) to the wastepipe nipple so that the face of outlet flange is 12mm fromfinished wall.

4. Place sponge rubber gasket onto waste fitting (beveledside facing urinal).

5. Place urinal on hangers and let gently slide down intoposition.

6. Secure waste fitting to urinal using the two bolts andwashers supplied.

7. Connect the flushometer valve to the supply nipple andurinal according to the flushometer valve manufacturer'srecommendations.

8. Check for tightness of all connetions and turn on the water.Flush urinal and adjust the control stop on the flushometervalve for flow volume, if needed.

For rear inlet s, when planning installation,installer must allow connection of inlet water supplybehind urinal.

urinal

-2-

12mm

152mm

OUTLET DETAILS

2" N.P.S.TAP

INSTALLATION

1037283-T01-B

Page 3: BARDON - KOHLER · bardon installation instructions top inletand rear inlet urinal k-4960t-et/k-4960t-er(3l) ... k-4960t-wet/k-4960t-wer(1l) top inletand rear inlet urinal 1037283-t01-b

IMPORTANTCONSUMER INFORMATION

CONSUMER RESPONSIBILITIES

If you live in a hard water area, make certain that the holes inthe toilet rim are kept clean to ensure proper flushing. Toiletbowl cleaners should be used at least once a week. Use along-handled brush to clean the rim holes, and to clean as farinto the trap as possible to prevent mineral deposits fromforming.

Most toilet bowl cleaners are not harmful to the vitreous chinasurface of the urinal. Please follow the bowl cleanermanufacturer's instructions carefully.

Do not use abrasive cleaners or solvents.

Donot use cleaners inside the wash basin. Productscontaining chlorine (calcium hypochlorite) can seriouslydamage fittings in the urinal. This damage can causeleakage and property damage.

Kohler Company shall not be responsible or liable for anydamage to these urinal fittings caused by the use of cleanerscontaining chlorine (calcium hypochlorite).

WARNING: Risk of property or product damage.

-3-1037283-T01-B

Page 4: BARDON - KOHLER · bardon installation instructions top inletand rear inlet urinal k-4960t-et/k-4960t-er(3l) ... k-4960t-wet/k-4960t-wer(1l) top inletand rear inlet urinal 1037283-t01-b

53405Collar, Female

18376Urinal Spud Assy.3/4

53407-BCScrew

53410Washer

51543-BCWasher

1018203Slip Nut Assy.

85061Beehive StrainerAssy.

52046Hanger Accessory Pack

-4-