41
Basic physiology of fMRI: signal and noise

Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Basic physiology of fMRI: signal and noise

Page 2: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Overview

•  Brief overview of fMRI •  Contrast mechanisms

–  Source of the fMRI signal

•  Sources of Noise (& corrections) –  Motion

–  Cardiac

–  Respiration

Page 3: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Brain activity during cued finger tapping

Page 4: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Measuring Brain Function with MRI

Task

Neuronal Activity

Red Blood Cells

Page 5: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

How can we see brain function with MRI?

red blood cells

oxygenated

deoxygenated

L. Pauling, C. D. Coryell, Proc.Natl. Acad. Sci. USA 22, 210-216, 1936.

Oxygenated and deoxygenated red blood cells have different magnetic properties

diamagnetic

paramagnetic

Page 6: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Detecting “activation”

Capillaries!

Veins!Arteries!

Capillaries!

Veins!Arteries!

χ1 χ2 χ2 χ2

ΔS =

0

0.2

0.4

0.6

0.8

1

1.2

0 50 100 150 200

M0a e-t/T2*a - M0r e-t/T2*r

time

Sig

nal

ΔS S0

= M0a

M0r e-tΔR2* - 1

Page 7: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Measuring Brain Function with MRI

Task

t

t

task Hemodynamics Neuronal Activity

Red Blood Cells

Task Blood Flow deoxy-Hb MRI signal

BOLD = Blood Oxygenation Level Dependent

Page 8: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

The Blood Oxygenation Level Dependent Response

Task

neuronal activity

BF

deoxy-Hb

MR signal

Page 9: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

The Blood Oxygenation Level Dependent Response

Task

neuronal activity

BF

HbO2 deoxy-Hb

MR signal

CMRO2 BV - - +

0 20 40 60

Time (sec)

Sig

nal

0 5 10 15 Time (sec)

Sig

nal

Page 10: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Temporal dynamics of fMRI signal change

Delay

Activation amplitude

Arbitrary Scale

+ 2 sec

- 2 sec

0 sec 0 10 20 30 40 50

-2 -1.5 -1 -0.5 0 0.5 1 1.5 2

Num

ber o

f Vox

els

Delay (sec)

t

task fMRI signal

0 10 s

Page 11: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Functional Magnetic Resonance Imaging (fMRI)

Typical MRI t

Functional MRI

Look for changes in MRI signal over time

Task Blood Flow MRI signal deoxy-Hb

Page 12: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Brain activity during cued finger tapping

t

t

task

Map the changes in MRI signal over time

Page 13: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Functional MRI

t

t

Task-related Neuronal Activity

Physiologic noise (cardiac, respiration)

Subject motion

Scanner instabilities Image reconstruction errors

Spontaneous Neuronal Activity

Hemodynamics resting state

Page 14: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Problem: Subject Motion

motion

t

t

t

Signal changes occur at edges

t

Page 15: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Correcting for subject motion

•  Image registration

t = 0 t = 1

•  Prevent Motion

•  Regress out motion-related changes

Page 16: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Problem: motion during the volume

Page 17: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Problem: motion during the volume

slices are actually acquired like this… expected acquisition:

Page 18: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Problem: motion during the volume

Potential solution: Prospective motion correction

slice tracks with the motion

•  C.C. Lee, et al., Magn. Res. Med., 39, 1998. •  H.A. Ward, et al., Magn. Res. Med., 43, 2000. •  O. Speck, et al., Magma 19, 2006.

Page 19: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Physiological noise

0 40 80 120 160 200 240 280 320 time (s)

Cardiac

M.S. Dagli et al., NeuroImage 9, 1999

Respiration

time 00 TIME = 110 s

ΔΦ =90 o 400

200

B0

Field Map

Figure courtesy of J. Bodurka

Page 20: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Can filtering (<0.1Hz) reduce cardiac noise?

0 5 10 15 20 time (s)

Sign

al

Cardiac fluctuation (1.1 Hz) Sampled every TR (2s)

0 0.5 1 1.5 2 Frequency (Hz)

0

0.1

0.2

0.3

Pow

er

•  Not always: Aliasing

Page 21: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Correction of physiological noise

RETROICOR (G. Glover et al., Magn. Reson. Med. 44, 2000.)

Pulse Oximeter

0 1 2 3 4 5 6 7 8 9 10 time (s)

Respiration

MR Images

φc

φr

sin( φc )

cos( φc )

sin( 2φc )

cos( 2φc )

sin( φr )

cos( φr )

sin( 2φr )

cos( 2φr )

Additional Regressors:

Page 22: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Correction of physiological noise

time

Sig

nal

Reshuffle the data based on its cardiac or respiration phase

0 1 2 3 4 5 6

Sig

nal

phase

Page 23: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Correction: Cardiac + Respiration

X. Hu et al., Magn. Res. Med. 1995

Page 24: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

At what stage should physio correction be done?

•  Preprocessing –  Motion correction –  Physiological noise correction –  Slice time correction –  Nuisance Regression –  Spatial Smoothing –  Convert to percent signal change –  Temporal filter

•  Define ROI (seed) •  Average EPI time course over ROI •  Regression T.B. Jones et al., Neuroimage 42, 2008

Page 25: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Physio. fluctations can occur at low frequencies

Variations in breathing during rest ΔBOLD signal

PETCO2

BOLD (GM)

BOLD (WM)

R.G. Wise et al., NeuroImage 21, 2004

ΔPETCO2 correlated w/ ΔBOLD

Page 26: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Resting fluctuations in respiration

RVT = Respiration Volume per Time

50 100 150 200 250 300 350

0

6

|Z|

group (n=11)

RVT-related changes

RVT

Page 27: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Heart Rate

Birn et al. (unpublished)

Page 28: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

RVHRcor (Respiration Volume + Heart Rate)

C. Chang et al., Neuroimage 2009

Page 29: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Nuisance Regression

H.J. Jo et al., NeuroImage 52, 2010

Page 30: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

The effect of global signal regression

The global signal is highly correlated w/ RVT

-1

-0.5

0

0.5

1

CC

: RV

T ~

glob

al s

igna

l

without global regression

with global regression

Connectivity maps

0.5

0.3

-0.1

0

(separate study, n = 18)

Page 31: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Global Signal Regression

K. Murphy, et al., Neuroimage, 2008

Can introduce anti-correlations

Page 32: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Global Signal Regression

Z.S. Saad, et al., Brain Connectivity, 2012

Can alter group differences …under certain conditions

Page 33: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Nuisance Regression

H.J. Jo et al., NeuroImage 52, 2010

Page 34: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

PSTCor (Phase-shifted Soft Tissue Corr.)

J.S. Anderson et al., HBM 32, 2011

Page 35: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

“FIX” (FMRIB’s ICA-based X-noisifier)

L. Griffanti, et al., Neuroimage 2014

Page 36: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

ICA-AROMA

Page 37: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

ICA-AROMA

R.H.R. Pruim et al., NeuroImage 112 (2015)

Page 38: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Tools to correct for physiological noise

•  Filtering - Works only if TR is short enough (< 400ms)

•  IMPACT (Chuang et al., 2001) – if TR short enough

•  Retrospective correction (k-space) (X. Hu et al., 1995)

•  RETROICOR (Glover et al., 2000)

•  CORSICA (V. Pelbarg, et al., 2007)

•  PESTICA (E.B. Beall, et al., 2007)

•  RVTcor (R.M. Birn, et al., 2006) •  RVHRcor (C. Chang, et al., 2009) •  ANATICOR (H-J. Jo, et al., ) •  APPLECOR, PEARCOR (M Marx, et al., 2013) •  PSTCor (J.S. Anderson, et al., 2011) •  CompCor (Y. Behzadi, et al., 2007)

•  FIX (L. Griffanti, et al., 2014)

•  ICA-AROMA (###, et al., 2015)

Page 39: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Should we perform physio corrections?

•  Reduces fluctuations related to heart beat and respiration –  Reduce false positives –  Reduce false negatives

•  Some physiological fluctuations are

associated with neuronal activity –  E.g. Heart rate variability

This is still an open question in the field

Page 40: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

Signal / Physiologic Noise

Tem

pora

l Sig

nal t

o N

oise

Rat

io

TSNR vs SNR

Signal-to-Noise Ratio

Page 41: Basic physiology of fMRI: signal and noise Materials...(cardiac, respiration) Subject motion Scanner instabilities Image reconstruction errors Spontaneous Neuronal ... R.G. Wise et

J. Bodurka

TSNR vs SNR