Instruction Manual & Safety Warnings IMPORTANT: Even if you have the Pro Series 1730 Backup Sump Pump System installed by someone else, you must read and follow the safety information contained in this manual. Failure to do so could result in property damage, serious injury, or death. Battery Backup Sump Pump System Table of Contents Important Safety Warnings and Instructions Electrical Precautions 1 Battery Preparation 1 Battery Precautions 1 Introduction Items Included in System 2 Additional Items Needed 2 System Specifications 2 Replacement Parts List 2 Pump & Pipe Installation Instructions Installation Options 3 Direct Discharge to Outside 4 Hookup to Existing Discharge 5 Direct Discharge for Narrow Sumps 6 Hookup to Existing Discharge for Narrow Sumps 7 Battery Instructions Preparation of the Battery 8 Control Unit Hookup Positioning the Float Switch 9 Hooking Up the Pump 9 Installing the Battery Fluid Sensor 9 Hooking Up the Battery 9 Hooking Up the Charger 9 Understanding the Warning Lights and Alarms Understanding the Automatic Charging System 10 Silencing the Alarm During an Emergency 10 Battery Alarm 10 Cleaning Battery Terminals 10,11 Replacing the Battery 11 Fuse Alarm 11 Water Alarm 12 Power Alarm 12 Pump Alarm 12 Replacing the Pump 12,13 Testing the System Test-Reset-Silence Button 13 Testing the Float Switch 13 Parts & Service Information Technical Support 13 Quick Reference Guide 14 Warranty 14

Battery Backup Sump Pump System & Safety Warnings

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Instruction Manual& Safety Warnings

IMPORTANT: Even if you have the Pro Series 1730 Backup SumpPump System installed by someone else, you must read and followthe safety information contained in this manual. Failure to do socould result in property damage, serious injury, or death.

Battery BackupSump Pump

SystemTable of Contents

Important Safety Warnings andInstructionsElectrical Precautions 1Battery Preparation 1Battery Precautions 1

IntroductionItems Included in System 2Additional Items Needed 2System Specifications 2Replacement Parts List 2

Pump & Pipe Installation InstructionsInstallation Options 3Direct Discharge to Outside 4Hookup to Existing Discharge 5Direct Discharge for Narrow Sumps 6Hookup to Existing Discharge for Narrow Sumps 7

Battery InstructionsPreparation of the Battery 8

Control Unit HookupPositioning the Float Switch 9Hooking Up the Pump 9Installing the Battery Fluid Sensor 9

Hooking Up the Battery 9Hooking Up the Charger 9

Understanding the WarningLights and AlarmsUnderstanding the Automatic Charging System 10Silencing the AlarmDuring an Emergency 10Battery Alarm 10Cleaning Battery Terminals 10,11Replacing the Battery 11Fuse Alarm 11Water Alarm 12Power Alarm 12Pump Alarm 12Replacing the Pump 12,13

Testing the SystemTest-Reset-Silence Button 13Testing the Float Switch 13

Parts & Service InformationTechnical Support 13

Quick Reference Guide 14

Warranty 14

Important SafetyWarnings & Instructions

SAVE THESE INSTRUCTIONS. This manualcontains important SAFETY WARNINGS andOPERATING INSTRUCTIONS for the Pro Series1730 Battery Backup Sump Pump System. Youwill need to refer to it before attempting anyinstallation or maintenance. ALWAYS keep theseinstructions with the unit so that they will beeasily accessible.

Failure to read and follow these warnings andinstructions could result in property damage,serious injury, or death. It is important to readthis manual, even if you did not install the ProSeries 1730 backup sump pump, since thismanual contains safety information regardingthe use and maintenance of this product. DONOT DISCARD THIS MANUAL.

ELECTRICAL PRECAUTIONS

Risk of electrical and fire hazard. May resultin death, serious injury, shock or burns.

To help reduce these risks, observe the following precautions:• DO NOT walk on wet areas of the basement

until all power has been turned off. If themain power supply is in a wet basement, callan electrician.

• NEVER handle the control unit with wet handsor while standing on a wet surface.

• ALWAYS unplug the control unit and dis-connect the cables from the battery beforeattempting any maintenance or cleaning.

• ALWAYS unplug the main pump when instal-ling or servicing the backup pump to avoidelectric shock.

• Remove personal metal items such as rings,bracelets, watches, etc. when working with alead-acid battery. A short circuit through oneof these items can melt it causing a severeburn.

• DO NOT expose the control unit to rain orsnow.

• Pull the plug rather than the cord whendisconnecting the control unit.

• An extension cord should not be used unlessabsolutely necessary. If an extension cordmust be used, be sure the plug has the sameconfiguration as the plug on the control unit.

• Use of an attachment not recommended orsold by the manufacturer may result in a riskof fire or injury from an electrical shock.

• DO NOT operate the computer control unit if ithas received a sharp blow, been dropped, orotherwise damaged in anyway. ContactGlentronics technical support at 800-991-0466, option #3.

• DO NOT disassemble the control unit. Whenservice is required, contact Glentronics tech-nical support at (800) 991-0466, option #3.Return the control unit to the manufacturer forany repairs at the following address:

Glentronics, Inc.1150 Willis Ave.

Wheeling, IL 60090

BATTERY PREPARATION

Sulfuric acid can cause blindness or severeburns. Avoid contact with skin, eyes orclothing. In the event of accident, flushwith water and call a physician immediately.KEEP OUT OF REACH OF CHILDREN.

To help reduce these risks, observe thefollowing precautions:• Someone should be within range of your voice

or close enough to come to your aid when youwork near a lead-acid battery.

• Have plenty of fresh water and soap nearby incase battery acid contacts skin, clothing oreyes.

• Wear eye and clothing protection and avoidtouching your eyes while working with batteryacid or working near the battery.

• If battery acid contacts skin or clothing, washimmediately with soap and water. If acidenters eye, immediately flood eye with run-ning cold water for at least 10 minutes and getmedical attention.

• Batteries posts and terminals contain lead andlead compounds, chemicals known to the Stateof California to cause cancer and reproductiveharm. Wash hands after handling.

BATTERY PRECAUTIONS

Explosive gases could cause serious injury ordeath. Cigarettes, flames or sparks couldcause battery to explode in enclosed spaces.Charge in well-ventilated area. Alwaysshield eyes and face from battery. Keep ventcaps tight and level.

To help reduce these risks, observe thefollowing precautions:• NEVER smoke or allow a spark or flame in the

vicinity of the battery.• Use the Pro Series 1730 control unit for

charging a LEAD-ACID battery only. Do notuse the control unit for charging dry-cellbatteries that are most commonly used withhome appliances.

• Be sure the area around the battery is wellventilated.

• When cleaning or adding water to the battery,first fan the top of the battery with a piece ofcardboard or another non-metallic material toblow away any hydrogen gas that may havebeen emitted from the battery.

• DO NOT drop a metal tool onto the battery. Itmight spark or short-circuit the battery andcause an explosion.

• ALWAYS remove the charger from the electricaloutlet before connecting or disconnecting thebattery cables. Never allow the rings to toucheach other.

• Check the polarity of the battery posts. ThePOSITIVE (+) battery post usually has a largerdiameter than the NEGATIVE (-) post.

• When connecting the battery cables, firstconnect the small ring on the end of theBLACK wire to the NEGATIVE (-) post of thebattery, and then connect the large ring onend of the RED wire to the POSITIVE (+) postof the battery.

Do not use system to pump flammable orexplosive fluids such as gasoline, fuel oil,kerosene, etc.

Page 1

! DANGER

! DANGER

! WARNING / POISON

! DANGER

POSITIVE POST HASLARGER DIAMETER

NEGATIVE POST HASSMALLER DIAMETER

Introduction

The Pro Series 1730 backup sump pump systemis battery-operated. It is designed as anemergency backup system to support yourregular AC sump pump, and it will automaticallybegin pumping anytime the float switch isactivated. Should any malfunction or emergencyoccur that involves the sump pump, the battery,or the AC power, your Pro Series 1730 system willsound an alarm. A light on the display panel ofthe control unit will indicate the cause of thealarm and the corrective action.

The Pro Series 1730Sump Pump System includes:

� A control unit with a float switch and abattery fluid level sensor

� A pump with 11⁄2” PVC pipe adapter� A plastic wire tie for mounting the float

switch� A battery box� A battery cap with a hole to accommodate

the fluid sensor� A battery charger� A 20-amp fuse� Corrosion protection material� A battery filler for adding distilled water to

the battery

You will also need to supply:

� A Pro Series 2200 Standby Battery, oranother deep cycle battery (Do not use a maintenance-free or a sealedbattery.)

� 11⁄2” rigid PVC pipe and fittings � PVC cement and primer� A rubber union with hose clamps or a “Y”

connector and two (2) check valvesdepending on the installation method youuse

� Six (6) quarts of 1.265 specific gravitybattery acid

For narrow sump pits you will need someadditional parts:

� An “L” bracket at least 6 inches long.(Preferably one that will not rust.)

� Two (2) stainless steel hose clamps� One (1) stainless steel screw (#8-32 x 3/4”),

a matching washer & nut

System SpecificationsPower supply requirements. . . . . . 115 volts ACPumping capacity. . . . . . . . . . 2500 GPH @ 0’Pumping capacity . . . . . . . . . 1730 GPH @ 10’Pump dimensions . . . . . . . . . . . 71⁄4 H x 5” WPump dimensions w/elbow . . . . . 71⁄4 H x 9” WPump housing & strainer . . . . . .Non-corrosive,

will not rustPump . . . . . . . . . . . . . . . . . . . .Can run dry;

can be used in sumps withwater softener or laundry discharge

Float switch . . . . . . . . . . Independent; can be set at any level

Replacement Parts ListDescription Part No.Pump 1011007Float switch assembly 1020003Fluid sensor assembly 1014001Pipe Adapter 1120002Charger 1015001Battery Box 1113003Corrosion protector 1305000Battery cap with hole 1125000

Call 800-991-0466 to order parts.

Page 2

BatteryWires

Control Unit

BatteryBox

Charger

Cap

Wire Tie

FloatSwitch Pipe

Adapter

Pump

Fluid Sensor

BatteryFiller

CorrosionProtection

Pump & PipeInstallation Instructions

There are two basic methods that can be used toinstall the pump, a direct discharge to theoutside of the building, or a hookup to anexisting discharge pipe. The same two optionsapply in very narrow sump pits where the backuppump must be mounted above the main pump.

Whenever possible, install your Pro Series 1730backup pump with a direct discharge to theoutdoors. By using this method, there willalways be an outlet for the water from the sump.During times of very heavy rain, many stormsewers fill up. If your pump is trying todischarge water into a full sewer, there isnowhere for the water to go. By dischargingdirectly outdoors, there is always an outlet forthe water that is pumped out of the sump. Forthis method, you will need to drill a hole througha floor joist or the foundation from the basementto the outside of the house.

If the direct discharge method is not possible orconvenient, the Pro Series pump can be hookedup to the same line as your AC sump pump byinstalling a “Y” connector and two check valves.

In most cases the backup pump will fit next tothe main AC pump in the sump pit. In verynarrow pits, the backup pump can be mountedabove the main pump. Try to fit the backuppump on the floor of the sump first.

Select the installation method that will best suityour needs from the diagrams at the right. Fullinstructions for each installation method areprovided on the following pages.

Installation will take a couple hours.

Page 3

NORMAL SUMP PITINSTALLATIONS

PUMPWIRE

PIPE ADAPTER

BASEMENT WATCHDOGPUMP

FLOORJOIST

MAIN AC PUMP

RIGID1-1/2"

PVC PIPE

CHECKVALVE

DRAIN TILE

1/8" HOLE

45° ELBOW

"Y" CONNECTOR

CHECKVALVE

PUMPWIRE

HOSE CLAMPSPIPE ADAPTER

BASEMENT WATCHDOGPUMP

"L" BRACKET

FLOORJOIST

MAIN AC PUMP

RIGID1-1/2"

PVC PIPE

CHECKVALVE

RIGID1-1/2"

PVC PIPE

DRAIN TILE

45° ELBOW

"Y" CONNECTOR

CHECKVALVE

1/8" HOLE

PUMPWIRE

PIPE ADAPTER

DRILL 1/8" HOLEIF CHECK

VALVE USED

BASEMENT WATCHDOG

PUMP

FLOORJOIST

MAIN AC PUMP

SLOPEPIPEDOWN

RIGID1-1/2"

PVC PIPE

RUBBERUNION

OR CHECKVALVE

CHECKVALVE

DRAIN TILE

PUMPWIRE

CHECKVALVE

HOSE CLAMPS

"L" BRACKET

FLOORJOIST

MAIN AC PUMP

SLOPEPIPEDOWN

RIGID1-1/2"

PVC PIPE

RUBBERUNION

OR CHECKVALVE

DRAIN TILEPIPE ADAPTER

DRILL 1/8" HOLEIF CHECK

VALVE USED

BASEMENT WATCHDOGPUMP

Installation BHookup toExistingDischarge PipePage 6

Installation CDirect Discharge

to OutsidePage 7

Installation DHookup toExistingDischarge PipePage 8

Installation ADirect Discharge

to OutsidePage 5

NARROW SUMP PITINSTALLATIONS

Page 4

Pump & PipeInstallation Instructions

INSTALLATION A: DIRECT DISCHARGE TO THE OUTSIDE OF THEBUILDING (Diagram A)

sDANGERUnplug the main AC pump when installingthe backup pump to avoid electric shock.Failure to do so could cause serious injuryor death.

1. Cut a four-foot (4’) piece of 11⁄2” rigid PVCpipe and cement it to the pipe adapter thatis attached to the elbow on the pump.

2. Secure the pump wire so that the plug on theend will not fall into the sump. Attach thewire to the pipe with a piece of tape.

3. Place the pump with the 4’ PVC pipeattachment on the bottom of the sump floornext to the main AC pump. Do not mountthe pump to any existing pipes; it should beplaced on the floor of the sump. A brick may

be placed under the pump if there are rocksor other debris on the sump floor that mayclog the pump.

4. Attach a rubber union or check valve (soldseparately) to the top of the 11⁄2” pipe. Thiswill allow the pump to be removed easily,should the need arise.

The path of the rest of the pipe and the detailsof each installation will vary. Using soundplumbing practices, try to route the dischargepipe to an exterior wall via the shortest pathwith the fewest turns. More turns will reducethe pumping capacity. The pipe section exitingthe building should be on a downward slope sothat the water in the pipe will exit outsideinstead of returning to the sump. Extend thedischarge pipe outside the building as far aspossible to avoid the return of discharged waterto the sump. Be sure to seal the hole in the wallwhere the pipe exits and cement or clamp allconnections securely to prevent leaking. Nocheck valve is needed with this method ofinstallation, as long as you use less than 20feet of pipe.

CAUTION

If you use more than a total of 20 feet of pipein the installation, install a check valve inplace of the rubber union. Make sure it isinstalled with the arrow pointing up or it willnot prevent the backflow of water. When acheck valve is used, a 1/8” hole must be drilledin the PVC pipe 3” above the Pro Series pump.If a hole is not drilled above the pump, an airlock may prevent the pump from operating, andthe basement will flood.

PUMPWIRE

PIPE ADAPTER

DRILL 1/8" HOLEIF CHECK

VALVE USED

BASEMENT WATCHDOG

PUMP

FLOORJOIST

MAIN AC PUMP

SLOPEPIPEDOWN

RIGID1-1/2"

PVC PIPE

RUBBERUNION

OR CHECKVALVE

CHECKVALVE

DRAIN TILE

1

2

3

4

Diagram A

! DANGER

CAUTION

Page 5

Pump & PipeInstallation Instructions

INSTALLATION B: HOOKUP TO AN EXISTING DISCHARGE PIPE (Diagram B)

sDANGERUnplug the main AC pump when installing thebackup pump to avoid electric shock. Failureto do so could cause serious injury or death.

1. Cut a four-foot (4’) piece of 11⁄2” rigid PVCpipe and cement it to the pipe adapter that isattached to the elbow on the pump.

2. (a) Install a check valve on the PVC pipeattached to the Pro Series pump. Make sureit is installed with the arrow pointing up or itwill not prevent the backflow of water.

CAUTION2. (b) When a check valve is used, drill a 1/8”

hole in the 11⁄2” PVC pipe three inches (3”)above the connection to the Pro Series pump.Drill the hole at a 45º angle toward thebottom of the sump to avoid splashing wateroutside the sump pit. If a 1/8” hole is notdrilled above the pump, an air lock mayprevent the pump from operating, and thebasement will flood.

3. If there is no check valve on the main ACpump, one must be installed at this time.Then install a “Y” connector above the check

valve on the discharge pipe for the main ACpump.

4. Secure the pump wire so that the plug on theend will not fall into the sump. Attach thewire to the pipe with a piece of tape.

5. Place the pump with the 4’ PVC pipeattachment on the bottom of the sump floor,next to the main AC pump. Do not mount thepump to any existing pipes...it should beplaced on the floor of the sump. A brick maybe placed under the pump if there are rocks orother debris on the sump floor.

6. Connect a 11⁄2” diameter discharge pipe abovethe check valve of the Pro Series pump, andattach a 45º elbow to that pipe. Extendanother piece of pipe to reach the “Y”connector you have inserted above the checkvalve on the discharge pipe of the mainpump.

7. Cement or clamp all connections securely toprevent leaking.

PUMPWIRE

PIPE ADAPTER

BASEMENT WATCHDOGPUMP

FLOORJOIST

MAIN AC PUMP

RIGID1-1/2"

PVC PIPE

CHECKVALVE

DRAIN TILE

1/8" HOLE

45° ELBOW

"Y" CONNECTOR

CHECKVALVE

Diagram B

3 4

5 6

2a 2b

CAUTION

! DANGER

1

Page 6

Pump & PipeInstallation Instructions

INSTALLATION C: DIRECT DISCHARGE TO THE OUTSIDE OF THE BUILDING FOR NARROW SUMP PITS (Diagram C)

sDANGERUnplug the main AC pump when installingthe backup pump to avoid electric shock.Failure to do so could cause serious injuryor death.

1. Attach an “L” bracket to the discharge pipe ofthe main AC pump with two (2) stainlesssteel hose clamps. Position the bracket sothe bottom of the “L” is just above the top ofthe main pump, and out of the way of anyfloat switch on the main pump.

2. (a) Remove the black bottom strainer of thepump by pressing in the two tabs on thestrainer. There are holes suitable formounting on the bottom of the strainer. (b)Using a #8-32 x 3/4” stainless screw, washer

& nut, attach the strainer to the “L” bracket.(c) Once the strainer is attached, simply pressthe pump body onto the mounted strainer.

3. Cut a three-foot (3’) piece of 11⁄2” rigid PVCpipe and cement it to the pipe adapter thatis attached to the elbow on the pump.

4. Secure the pump wire so that the plug on theend will not fall into the sump. Attach thewire to the pipe with a piece of tape.

5. Attach a rubber union or check valve (soldseparately) to the top of the 11⁄2” pipe. Thiswill allow the pump to be removed easily,should the need arise.

The path of the rest of the pipe and the detailsof each installation will vary. Using soundplumbing practices try to route the dischargepipe to an exterior wall via the shortest pathwith the fewest turns. More turns will reducethe pumping capacity. The pipe section exitingthe building should be on a downward slope sothat the water in the pipe will exit outsideinstead of returning to the sump. Extend thedischarge pipe outside the building as far as

possible to avoid the return ofdischarged water to the sump. Besure to seal the hole in the wallwhere the pipe exits and cement orclamp all connections securely toprevent leaking. No check valve isneeded with this method ofinstallation, as long as you use lessthan 20 feet of pipe.

PUMPWIRE

CHECKVALVE

HOSE CLAMPS

"L" BRACKET

FLOORJOIST

MAIN AC PUMP

SLOPEPIPEDOWN

RIGID1-1/2"

PVC PIPE

RUBBERUNION

OR CHECKVALVE

DRAIN TILEPIPE ADAPTER

DRILL 1/8" HOLEIF CHECK

VALVE USED

BASEMENT WATCHDOGPUMP

Diagram C

2c 4

5

3

CAUTION

! DANGER

1 2b2a

“L” BRACKET

If you use more than a total of 20 feet of pipe in theinstallation, install a check valve in place of therubber union. Make sure it is installed with the arrowpointing up or it will not prevent the backflow ofwater. When a check valve is used, a 1/8” hole mustbe drilled in the PVC pipe 3” above the Pro Seriespump. If a hole is not drilled above the pump an airlock may prevent the pump from operating, and the

basement will flood.

Page 7

Pump & PipeInstallation Instructions

INSTALLATION D: HOOKUP TO EXISTING DISCHARGE PIPE FOR NARROW SUMP PITS(Diagram D)

sDANGERUnplug the main AC pump when installing thebackup pump to avoid electric shock. Failureto do so could cause serious injury or death.

1. Attach the “L” bracket to the discharge pipeof the main AC pump with two (2) stainlesssteel hose clamps. Position the bracket so thebottom of the “L” is just above the top of themain pump, and out of the way of any floatswitch on the main pump.

2.(a) Remove the black bottom strainer of thepump by pressing in the two tabs on thestrainer. There are holes suitable formounting on the bottom of the strainer. (b)Using a #8-32 x 3/4” stainless screw, washerand nut, attach the strainer to the “L”bracket. (c) Once the strainer is attached,simply press the pump body onto themounted strainer.

3. Cut a three-foot (3’) piece of 11⁄2” rigid PVCpipe and cement it to the pipe adapter that isattached to the elbow on the pump.

4. (a) Install a check valve on the PVC pipeattached to the Pro Series pump. Make sureit is installed with the arrow pointing up or itwill not prevent the backflow of water.

4. (b) When a check valve is used, drill a 1/8”hole in the 11⁄2” PVC pipe three inches (3”)above the connection to the Pro Series pump.Drill the hole at a 45º angle toward the bottomof the sump to avoid splashing water outsidethe sump pit. If a hole is not drilled above thepump, an air lock may prevent the pump fromoperating, and the basement will flood.

5. If there is no check valve on the main ACpump, one must be installed at this time.Then install a “Y” connector above the checkvalve on the discharge pipe for the main ACpump.

6. Secure the pump wire so that the plug on theend will not fall into the sump. Attach thewire to the pipe with tape.

7. Connect a 11⁄2” diameter discharge pipe abovethe check valve of the Pro Series pump, andattach a 45º elbow to that pipe. Extendanother piece of pipe to reach the “Y”connector you have inserted above the checkvalve on the discharge pipe of the mainpump.

8. Cement or clamp all connections securely toprevent leaking.

PUMPWIRE

HOSE CLAMPSPIPE ADAPTER

BASEMENT WATCHDOGPUMP

"L" BRACKET

FLOORJOIST

MAIN AC PUMP

RIGID1-1/2"

PVC PIPE

CHECKVALVE

RIGID1-1/2"

PVC PIPE

DRAIN TILE

45° ELBOW

"Y" CONNECTOR

CHECKVALVE

1/8" HOLE

3

5

1

6 7

4a 4b

2a

2b 2c

Diagram D

“L”BRACKET

CAUTION

! DANGER

Page 8

Battery Instructions

A new Pro Series 2200 Standby Battery will run thissystem for a minimum of 7.5 hours continuously.However, most of the time the pump will turn onand off, and the battery will run the pumpintermittently for days. In addition, the uniquematerials in the battery enable it to last for five toseven years in standby service.

• The use of automotive batteries is NOT recom-mended. Automotive batteries are not designedfor this application. They will only run the pumpfor a short time and will have a shorter life thana standby battery.

• DO NOT use a maintenance-free or a sealedbattery. They are made of different materials andwill trigger a false “Battery problem” alarm.

• The battery fluid sensor and cap are designed tofit the Pro Series batteries. Measuring thebattery fluid is one of the most importantfeatures of the system; since about 80% ofbackup sump pump failures are the result of adead battery.

Do not use the enclosed battery cap on anybattery except a Pro Series battery. Do notdrill a hole in the cap of another brand ofbattery to accommodate the fluid sensor.Batteries emit explosive gases, which cancause serious injury or death.

PREPARING THE PRO SERIES 2200 STANDBY BATTERY

The Pro Series batteries are shipped dry (withoutacid) so they never lose power before you takethem home. A battery is activated when the acidis added, and then it slowly begins to deteriorateas it ages. By adding the acid just before use, thebattery will always be fresh. Use 1.265 specificgravity battery acid to fill the battery. It isavailable where you purchased the battery.

Wear eye and clothing protection. If batteryacid contacts skin or clothing, washimmediately with soap and water. If acid

enters eyes, flush with water for 10 minutesand get medical attention. Review the safetyinstructions on page 1.

1. Remove the battery box top by pushing in thetabs on the front and back of the box andlifting up.

2. Place the battery box on the floor. Place the dry(unfilled) battery into the battery box. Removethe foil seal on the top of the battery.

3.(a) Carefully push in the perforated tab at thetop of the acid pack. Lift up the large tab andpull out the dispensing hose. Hold the hoseupright above the pack and squeeze the hoseforcing all the acid back into the pack. (b)Position the acid pack and battery as shown atthe right. Remove the caps from the battery.Pinch the end of the hose together and cut offthe tip. Insert the end of the hose into eachcell. Control the flow by pinching the hose withthumb and forefinger. Fill each cell of thebattery to a level just covering the batteryplates, and then go back and top off each cellequally. It is important to have the cells filledequally or the battery will not operateproperly. The acid should reach a level justbelow the cap ring. (Diagram E)

A newly filled battery will sometimes requireadditional acid after about ten minutes. Re-examine the fill level and add additional acid, ifnecessary. The battery acid may bubble at thistime and give off a sulfur-like smell, but this isnormal. After the battery has been filled, screwthe caps on the top of the battery.

CAUTIONWhen you fill the battery for the FIRST time, it willbe the ONLY time you add acid to the battery. Inthe future, when the fluid level is low, add distilledwater to the cells. Never add more acid.

Do not throw an old battery in thetrash. Take it to a service station orrecycling center.

2nd LEVEL

1st LEVEL

PLATES

CELL WALL

1. FILL TO 1st LEVEL, COVER THE PLATES��2. THEN FILL TO 2nd LEVEL, JUST BELOW� THE BOTTOM OF THE CAP RINGS

BATTERY TERMINALS

BATTERY CAP RINGS

CROSS SECTION OF BATTERY

Diagram E

1 2

3a 3b

CAUTION

! DANGER

! DANGER

CAUTION

Page 9

Control Unit Hookup

Risk of electrical shock or battery explosion,which can cause serious injury or death.Unplug the main AC pump to avoid electricalshock. Wear eye protection. Work in a well-ventilated area. Do not smoke or allow aspark or flame in the vicinity of the battery.Avoid dropping metal tools on the battery.If battery acid contacts eyes, flush withwater for 10 minutes. Review the safetyinstructions on page 1.

When you position the control unit, be sure thecharger cord will reach the AC power outlet andthe pump cable and the float switch will reachthe bottom of the sump. Position the unit in awell-ventilated area. (Diagram F)

1. Positioning the float switch: The floatswitch will turn on the pump when the waterrises to the top of the switch, and it willremain running as long as the water is abovethe float switch. When the water drops belowthe float switch, an internal timer in thecontrol unit will keep the pump running anadditional 25 seconds to empty the sump pit.The switch should be mounted about sixinches (6”) above the water level line in thesump pit. (a) Attach the float switch verysecurely to the discharge pipe with the plasticwire tie. (b) If the pump is stacked above themain AC pump in a narrow sump pit, the floatmay be attached to the elbow of the pump.Be sure the switch is positioned vertically withthe mounting bracket at the top. Do not tiltthe switch. Do not position the float switch onthe side of the discharge pipe facing the draintile or any incoming rush of water!

2. Hooking up the pump: Remove the securitytag from the pump and plug the pump wiresinto the pump connector on the back of thecontrol unit.

3. Installing the battery fluid sensor: Removethe cover of the battery box by pushing in thetabs on the front and back, then lifting up.Fan the area around the top of the batterywith a piece of cardboard (or another non-metallic material) to remove any hydrogengas that may have been emitted from thebattery. Replace the battery cap that is 2ndfrom the POSITIVE (+) post of the battery with

the yellow battery capthat is provided in the ProSeries 1730 package. Anarrow on the top of thebattery marks thisposition. There are twoholes in the battery cap.Insert the fluid sensor inthe hole that is off-centeron the top of the cap. Donot glue the sensor intothe cap.

CAUTIONIf you are not using the Pro Series battery, youcannot use the battery fluid sensor. Howeveryou must attach the sensor to the POSITIVE (+)post of the battery or the alarm will soundcontinuously. The Pro Series 1730 Sump PumpSystem will not warnyou if the fluid level islow in this configur-ation. You will need tocheck your batteryevery couple of monthsto see if it needs water.If the battery driesout, the system willnot work.

4. Hooking up the battery: Remove the wingnuts from the battery terminals. Remove thesecurity tag from the battery cables. (a)Apply the corrosion material to the posts ofthe battery. (It has been provided with thesystem. Read the instructions on thepackage.) (b) Attach the battery cables tothe battery...the BLACK wire to the NEGATIVE(-) post, and then the RED wire to thePOSITIVE (+) post. Replace the wing nuts andtighten.

5. Hooking up the charger: Immediately plugthe charger into the charger hole on the backof the control unit, then into an AC outlet onthe wall. (You can provide additionalprotection for the control unit by using asurge protector.)

6. Secure the cover on the battery box byslipping the tabs through the fittings on thefront and back of the box. BE SURE TO PLUGIN THE MAIN AC PUMP.

CHARGER

BATTERYBOX

PUMPWIRE

DRAIN TILE

MAIN AC PUMP

FLOAT WIRE

FLOAT SWITCH

PIPE ADAPTER

BASEMENT WATCHDOGPUMP

WIRETIE

WATERLEVEL LINE

BLACKBATTERYCABLE

BATTERY

TERMINAL

WALL OUTLET

RED BATTERY CABLE

SENSOR

CONTROL UNIT

1b

4a

3

54b

2

Diagram F

FUSE

CHARGER PUMP

FUSE

CHARGER

! DANGER

1a

PUMP

Page 10

Understanding the Warnings & Alarms

The Pro Series 1730 control unit features a seriesof warning lights that pinpoint potentialproblems. In addition, an alarm sounds to alertyou to the problem. In some cases, the lightsand alarm will go off automatically when theproblem has been solved. In others, the GRAYbutton must be pushed to silence the alarm.Refer to the table below for a quick review of thefeatures and their corresponding alarm status.

UNDERSTANDING THEAUTOMATIC CHARGING SYSTEMThe Pro Series 1730 is equipped with acomputer-controlled automatic charging system.The computer is constantly monitoring thebattery and will supply a pre-programmedamount of energy to keep your battery at fullcharge. The CHARGING light will be on while thebattery is charging, and off when it is notcharging. The normal charge cycle is in one-hour increments, which increases the life of thebattery and reduces the amount of water loss. Ifthe battery is discharged from extended use, thecharger will remain on until the battery iscompletely recharged.

SILENCING THE ALARMDURING AN EMERGENCYThe Pro Series 1730 allows you to silence thealarm during an emergency, however the warninglight will remain on until the problem iscorrected.• Press the GRAY button for 1 second to reset

the pump alarm, and silence the other alarmsfor 2 minutes.

• Press the GRAY button for 5 seconds to silencethe alarms for 24 hours. A brief buzzingsound will notify you that the alarms have

been silenced. The alarms will automaticallyreactivate in 24 hours if the warningconditions still exist.

BATTERY ALARMThis light and alarm will go on when the controlunit senses that the battery has approximately1/2 hour of continuous pumping energy left.This could occur when:• The pump has been running for many hours

and is reaching the last half-hour of operatingpower.

• The battery is getting old and should bereplaced.

• Corrosion on battery terminals and/or cablerings is preventing the battery from chargingproperly.

Check the battery cables and the battery terminalsfor corrosion. Clean and tighten them as needed.The procedure is described at the right.

If the battery alarm goes on while the pump isrunning and the power is out, you will have aminimum of 1/2 hour of pumping time to replacethe battery. (In most cases, the pump does notrun continuously, and therefore, you actuallyhave longer.) You will not be able to silence thealarm. Left unattended, the basement will flood.In a severe emergency, if a replacement batteryis not available, you could temporarily use yourcar battery.

Once the AC power is restored, the battery willrecharge automatically, unless it is old ordamaged. The alarm will remain on until theGRAY button is pressed for 1 second.

In the event that your Pro Series sump pumpsystem has pumped for an extended period oftime, the battery can become very depleted. Inthis condition, when the AC power is returned tothe unit, a battery alarm will continue to sound.The battery may need a longer period torecharge.

For a fast recharge, an automotive or marinebattery charger can be used to recharge thebattery. Follow the manufacturers instructionsand safety information included with the charger.

CAUTIONWhen another charger is used, first disconnectthe Pro Series charger from the control unit, andthen disconnect the control unit from thebattery. Charging without disconnecting thecontrol unit will destroy the control unit and voidthe warranty.

If the battery is relatively new and the batteryalarm is activated, before you replace thebattery, call the Glentronics service departmentat 800-991-0466, option #3.

TO CLEAN THE BATTERY TERMINALSAND CABLES

Risk of electrical shock or battery explosion,which can cause serious injury or death.Wear eye protection. Work in a well-ventilated area. Do not smoke or allow aspark or flame in the vicinity of the battery.Avoid dropping metal tools on the battery.If battery acid contacts eyes, flush withwater for 10 minutes. Review the safetyinstructions on page 1.

REFER TO THE PHOTOS ON PAGE 11.

1. Unplug the charger from the wall outlet.

2. Remove the cover of the battery box bypushing in the tabs on the front and back,then lifting up.

3. Fan the area around the top of the batterywith a piece of cardboard (or another non-metallic material) to remove any hydrogen gasthat may have been emitted from the battery.

4. Unscrew the wing nuts. Remove the batterycables and clean the battery posts with abattery post terminal cleaner or a wire brush.

5. Clean the corrosion off of the ring connectorson the ends of the battery wires. Use a stiffbrush or sandpaper.

6. Apply a terminal protective material.

Warning

BATTERY

FUSEWATER

PUMP

POWER

Alarm shuts offautomaticallywhen problem is corrected

No, must push"GRAY" button

YesYes

No, must push"GRAY" button

Yes, but light willflash until "GRAY" button is pushed

FRONT PANEL OF CONTROL UNIT

! DANGER

Page 11

7. If the fluid sensor has come out of the batterycap, replace it now. Then, replace the batterycables, BLACK to the NEGATIVE (-) post, andthen RED to the POSITIVE (-) post. Tightenthe wing nuts.

8. Plug the charger into the wall outlet. (Youcan provide additional protection for thecontrol unit by using a surge protector.)

REPLACING THE BATTERY

Risk of electrical shock or battery explosion,which can cause serious injury or death.Wear eye protection. Work in a well-ventilated area. Do not smoke or allow aspark or flame in the vicinity of the battery.Avoid dropping metal tools on the battery.If battery acid contacts eyes, flush withwater for 10 minutes. Review the safetyinstructions on page 1.

REFER TO THE PHOTOS AT RIGHT.

1. Unplug the charger from the wall outlet.

2. Remove the cover of the battery box bypushing in the tabs on the front and back,then lifting up.

3. Fan the area around the top of the batterywith a piece of cardboard (or another non-metallic material) to remove any hydrogen gasthat may have been emitted from the battery.

4. Remove the fluid sensor from the battery cap,and then remove the battery cap. Save it foruse in the new battery.

5. Unscrew the wing nuts and remove the batterycables.

6. Fill the battery following the instructions onpage 8.

7. (a) Apply the corrosion protection material tothe battery posts. (b) Replace the battery

cables, BLACK to the NEGATIVE (-) post, andthen RED to the POSITIVE (+) post.

8. Rinse and dry the YELLOW cap from the oldbattery to remove any residue. Replace theBLACK battery cap in the cell that is 2nd fromthe POSITIVE post with the YELLOW cap fromthe old battery. Insert the fluid sensor in thecap. Put the BLACK battery cap on the oldbattery.

9. Plug the charger into the wall outlet. (Youcan provide additional protection for thecontrol unit by using a surge protector.)

FUSE ALARM

Unplug the main AC pump when installing thebackup pump to avoid electric shock. Failureto do so could cause serious injury or death.

This alarm indicates that the 20-amp safety fuseon the back of the control unit has blown. Thiscan be the result of a clogged pump motor, orpump wires that have been shorted out. Todetermine the problem:

REFER TO THE PHOTOS ON PAGE 12.

1. Unplug the AC pump from the wall outlet.

2. Unplug the Pro Series pump from the back ofthe control unit.

3. (a) Release the rubber union or check valveand remove the pump from the sump pit.(b) Remove the strainer and clean out anydebris that may have collected in the pump.Replace the pump in the sump pit and tightenthe check valve or rubber union.

4. Replace the 20-amp fuse on the back of theunit, and then press the GRAY button. If thefuse blows again, the wires probably have ashort. Replace the pump with Pro Series partnumber 1011007. Leave the pump and pipein place until the new pump is installed.

5. Plug the AC pump into the wall outlet.

2

3

4

5

6

7a

8

6

7

! DANGER

! DANGER

7b

4 & 5

2

3

Remove

WATER ALARM

Risk of electrical shock or battery explosion,which can cause serious injury or death. Weareye protection. Work in a well-ventilated area.Do not smoke or allow a spark or flame in thevicinity of the battery. Avoid dropping metaltools on the battery. If battery acid contactseyes, flush with water for 10 minutes. Reviewthe safety instructions on page 1.

REFER TO THE PHOTOS AT RIGHT.

If this warning light and alarm are on, you need toadd distilled water to the battery.

1. Remove the top of the battery box by pushing inthe tabs on the front and back, then lifting up.

2. Fan the area around the top of the battery witha piece of cardboard (or another non-metallicmaterial) to remove any hydrogen gas that mayhave been emitted from the battery. Thenremove the fluid sensor from the battery cap.The alarm will sound when the sensor isremoved.

3. Unscrew the six battery caps. Add distilledwater to each cell. If distilled water is notavailable; tap water with a low mineral contentmay be used. Well water is not recommended.NEVER ADD MORE ACID. Fill the battery tolevel 2 as shown in Diagram E on page 8.

4. Replace the battery caps and the fluid sensor.Be sure the fluid sensor is positioned in the 2ndcell from the positive post. It’s marked with anarrow on the top of the battery. The warninglight and alarm will turn off automatically whenthe battery is refilled and the sensor is replaced.

5. Replace the battery box cover.

POWER ALARM

There are several causes for power failure. Themost common is a power outage by your electriccompany. During this emergency, the Pro Series1730 system will automatically switch to batterypower and protect your basement from flooding.You can silence the POWER alarm for 24 hours bypressing the GRAY button for 5 seconds. When thebutton is pressed for 5 seconds, you will hear abrief buzzing sound to notify you that the alarmshave been silenced for 24 hours. After 24 hours,the alarm will automatically reactivate. The pumpwill continue to operate while the alarm issilenced.

For your convenience, the POWER alarm has abuilt-in memory that will notify you when a poweroutage has occurred, and the power has since beenrestored. The alarm will turn off when the poweris restored, but the POWER light will flash (likeyour VCR). The flashing light will continue untilthe GRAY button is pressed for 1 second.

If the power is on in the rest of the house, checkthe home circuit breaker or fuse box for failure,and correct the problem.

Check the charger. Make sure it is securely pluggedinto the wall outlet.

Check the charger plug that fits into the rear panelof the control unit. Make sure it is securelyplugged into the control unit.

The control unit must receive 115 volts AC +/- 5%from the AC outlet. Any voltage lower than thiswill cause the power failure alarm to activate.

Lower voltages can be caused by utility companybrown outs or a heavy power draw from otherappliances on the same circuit.

If all the connections are secure and the walloutlet is operating, but the POWER warning light isstill on, replace the charger unit with Pro Seriespart number 1015001.

PUMP ALARM

When the water rises in the sump pit and activatesthe float switch, the pump will begin pumping,and the PUMP light and alarm will activate. ThePUMP warning stays on to alert you to the factthat the standby system was used to empty waterfrom the sump. Try to determine what caused thesystem to activate.

• Check the main pump for failure. It may not beworking, the float switch may be stuck, or it maybe too small to handle the inflow of water

• Make sure the check valve is working andinstalled correctly

• Make sure the discharge pipe is not clogged orfrozen

• If the power was out, and the backup pump wasactivated, you need to push the GRAY button tosilence the alarm

REPLACING THE PUMP

Unplug the main AC pump when installing thebackup pump to avoid electric shock. Failure todo so could cause serious injury or death.Review the safety instructions on page 1.

REFER TO THE PHOTOS ON PAGE 13.

1. Unplug the pump from the back of the controlunit.

2. Release the rubber union or check valve andremove the pump and the rigid PVC pipe sectionfrom the sump.

3. Unscrew the pipe and fitting from the old pumpand screw them into the new pump.

Page 12

! DANGER

2

4

3a

1

2

3

4

! DANGER

FUSE

CHARGER PUMP

FUSE

CHARGER PUMP

3b

4. Lower the pump into the sump and reconnectthe rubber union or check valve.

5. Plug the pump wires into the back of thecontrol panel.

BE SURE TO PLUG IN THE MAIN AC PUMP.

TEST-RESET-SILENCE BUTTON

To test the pump, press the GRAY button for 1second. The pump will run for 25 seconds andthen shut off automatically.

To silence any alarm, press the GRAY button for1 second.

To reset the BATTERY or PUMP alarm, press thebutton for 1 second.

To silence all the alarms for 24 hours, press theGRAY button for 5 seconds until you hear a buzz.The alarms will automatically re-activate in 24hours.

TESTING THE FLOAT SWITCH

It is important to manually test the floatswitch periodically.

Lift the float up and let go. This will activatethe pump. The control unit will run the pump forapproximately 25 seconds so it can empty all thewater in the sump pit. If there is no water inthe pit, the pump can run dry for this amount oftime. The alarm will sound and the PUMP lightwill go on. After the pump has stopped, pushthe GRAY button to silence the alarm. If theGRAY button is pressed before the pump hasstopped, the alarm will go off temporarily. Waitfor the pump to stop pumping, and then pushthe GRAY button to completely silence thealarm.

PARTS & SERVICE INFORMATION

You can receive technical support, parts orservice information by calling Glentronics, Inc.at (800) 991-0466 or visiting the website atwww.basementwatchdog.com. Send your unit tothe following address for repairs:

Glentronics, Inc.1150 Willis Ave.

Wheeling, IL 60090-5817

Page 13

LIFTFLOAT

1

4

5

2

3

FUSE

CHARGER PUMP

FUSE

CHARGER PUMP

Limited Warranty

GLENTRONICS, INC. warrants to the original retail purchaser that all of its pump, switch, sensor,battery box and control unit products are free from defective materials and workmanship for theperiod indicated below:

All parts and labor (excluding installation) for a period of three (3) years from the date of purchase

The defective product must be returned directly to the factory, postage prepaid with the originalbill of sale or receipt to the address listed below. Glentronics, Inc., at its option, will eitherrepair or replace the product and return it postage prepaid.

CONDITIONS

The unit must be shipped freight prepaid, or delivered, to Glentronics, Inc. to provide theservices described hereunder in either its original carton and inserts, or a similar packageaffording an equal degree of protection.

The unit must not have been previously altered, repaired or serviced by anyone other thanGlentronics, Inc., or its agent; the serial number on the unit must not have been altered orremoved; the unit must not have been subject to accident, misuse, abuse or operated contraryto the instructions contained in the accompanying manual.

The dealer’s dated bill of sale, or retailer’s receipt, must be retained as evidence of the date ofpurchase and to establish warranty eligibility.

This warranty does not cover product problems resulting from handling liquids hotter than 120degrees Fahrenheit, handling inflammable liquids, solvents, strong chemicals or severe abrasivesolutions; normal wear; user abuse; misuse, neglect, improper maintenance, commercial orindustrial use; improper connections or installation; damages caused by lightning strikes,excessive surges in AC line voltage, water damage to the controller, other acts of nature, orfailure to operate in accordance with the enclosed written instructions.

GLENTRONICS, INC. WILL NOT BE LIABLE FOR ANY INCIDENTAL, SPECIAL OR CONSEQUENTIALDAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTIES ON THIS PRODUCT. SOMESTATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF CONSEQUENTIAL OR INDIRECTDAMAGES, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. THIS EXPRESS WARRANTY SHALLBE EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, WRITTEN OR ORAL, EXPRESS ORIMPLIED, INCLUDING, BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESSFOR A PARTICULAR PURPOSE. THE CUSTOMER’S EXCLUSIVE REMEDY FOR BREACH OF THISWARRANTY, OR OF ANY IMPLIED WARRANTY NOT EXCLUDED HEREIN, SHALL BE LIMITED TOREPAIR OR REPLACEMENT OF THE PRODUCT.

For information or service contact:Glentronics, Inc.1150 Willis Ave.

Wheeling, IL 60090800-991-0466

Model # PHCC -1730 Serial # ___________________ Purchase Date_____________________

Page 14

BATTERYPossible ReasonsTerminals are corroded . . . . . . . . . . . . . . . . . .Cables are loose . . . . . . . . . . . . . . . . . . . . . .Battery is discharged . . . . . . . . . . . . . . . . . . .

Battery is damaged or old . . . . . . . . . . . . . . .

FUSE Possible ReasonsPump is clogged . . . . . . . . . . . . . . . . . . . . . .

Pump wires are exposed . . . . . . . . . . . . . . . . .Pump is defective . . . . . . . . . . . . . . . . . . . . .

WATER Possible ReasonsThe battery fluid is low . . . . . . . . . . . . . . . . .

PUMP Possible ReasonsThe main AC pump failed because of a power outage . . . . . . . . . . . . . . . . . . . .The main AC pump is defective . . . . . . . . . . . .The float switch on the main AC pump is jammed or defective . . . . . . . . . . .The main AC pump could not keep up with the inflow of water . . . . . . . . . . .

The float switch on the backup pump is defective . . . . . . . . . . . . . . . . . . . . . . . . .The check valve is stuck or installed improperlyand the water returns to the sump pit . . . . . . .The discharge pipe is blocked and the waterreturns to the sump pit . . . . . . . . . . . . . . . . .

POWER Possible ReasonsPower outage . . . . . . . . . . . . . . . . . . . . . . . .A fuse or circuit breaker has failed . . . . . . . . . .The charger is unplugged from the back of thecontrol unit, or unplugged from the wall . . . . . .The charger is receiving less than 110 volts fromthe outlet . . . . . . . . . . . . . . . . . . . . . . . . . .

ALARMRemediesClean terminals & cablesTighten wing nutsReplace battery if power is out. There is only 1/2 hourof continuous pumping power left. Battery will rechargewhen power is restoredReplace battery

ALARMRemediesRemove pump and strainer. Clean out any debrisReplace the 20-amp fuseReplace the pumpReplace the pump

ALARMRemediesAdd distilled water to the battery

ALARMRemedies

None. The backup pump was activatedReplace the main AC pump

Free the float switch or replace it

None. The backup pump was activated. If this is arecurring problem, install a higher capacity main pump

Replace the float switch

Replace the check valve or correct the installation

Clean out or replace the discharge pipe

ALARMRemediesNone. The backup pump will run on the batteryReplace the fuse or reset the circuit breaker

Make sure the charger is plugged in securely

None, if the utility company has instigated brown outs.Otherwise, reduce the number of other appliances on thecircuit

Quick Reference GuideRead safety warnings & instructions before attempting any repairs or maintenance.! DANGER

© 2003, Glentronics, Inc. 1806015