    INTERTEK ETL SEMKOConduit Systems: Medium Duty 

    Sizes: 20/25/32/50 mmTest Report Ref: 1301827-1

    S INTERTEK Certification for 

    Medium, Heavy & Extra Heavy Duty ConduitsCertificate Ref: 1301827

    S INTERTEK Certification for Junction Boxes

    Certificate Ref: 1313485

    INTERTEK ETL SEMKOConduit Systems: Heavy Duty 

    Sizes: 20/25/32/50 mmTest Report Ref: 1301827-2

    INTERTEK ETL SEMKOConduit Systems: Extra Heavy Duty 

    Sizes: 20/25/32/50 mmTest Report Ref: 1301827-3

    S INTERTEK Certification for 

    Fittings & Accessories for ConduitsCertificate Ref: 1313493

  • 8/20/2019 Bc Conduit Catalog

    3/34

    BC CONDUIT

    IEC, BRITISH & EUROPEAN SYSTEM

    AMERICAN SYSTEM

  • 8/20/2019 Bc Conduit Catalog

    4/34

     AREA Bahra Cables Company has a total land area of about 300,000sqm at disposal.

    The built-up area, including offices and plant, of start up phase is more than 100,000sqm.

    GENERALINTRODUCTION

    BC Conduit has started production of a variety of high quality unplasticised polyvinyl chloride (UPVC)

    compounds in its state-of-the-art factory in Bahra, which has an annual output capacity of over 36,000

    tons.

     

    The company sources UPVC feedstock for the new factory from Saudi Basic Industries Corporation

    (SABIC) to produce the granule used for jacketing and insulating the cables. SABIC is one of the world’s

    largest manufacturers of UPVC and the sole producer in Saudi Arabia.

     

    The factory built with the expertise of Buss Company of Switzerland, is completely integrated and

    equipped with the latest technologies in the field.

     

    The ability to manufacture UPVC compounds improves BCC’s control over the material used in its cable

    and wire production, reduces product cost and adds higher performance values to its products.

     

    The new factory also eliminates the need for local sourcing of UPVC compounds, ensures superiorquality production of cables and creates more career opportunities in the region at the same time.

    1

  • 8/20/2019 Bc Conduit Catalog

    5/34

    BC CONDUITMATERIAL SPECIFICATIONS

    MATERIAL INTRODUCTION

    Unplasticised Poly(Vinyl Chloride), commonly known as UPVC, was first recognized and characterizedmore 110 years ago, but due to its poor thermal stability making processing difficult, it was potentially

    introduced to the market only by 1930.

    The problem caused by poor thermal stability were overcome by development of suitable stabilizers

    systems and UPVC is now one of the world’s leading synthetic polymer having very diverse applications.

    The ability to change its properties, by the addition of plasticisers, from a hard rigid material to one that

    is soft and flexible enables a wide variety of processing equipment to be used to produce an almost

    limitless range of products to a thick cream.

    UPVC is used for the production of extrusions and molding. And it is universally accepted as having themost suitable properties for use within the electrical industry.

    BC Conduit StandardsBC Conduit UPVC products are manufactured in accordance with the British Standards, American

    Standard, SASO Standard, and UL Standards.

    (*BS 6099: Part 1; Conduit for electrical installations. Specification of general requirements, is

    superseded, withdrawn and replaced by BS EN 50086-1.

    BS EN 50086-1; Conduit for electrical installations. Specification of general requirements superseded

    and replaced by BS EN 61386-1).

    BS EN 61386 (IEC 61386), Conduit Systems for cable management.

    SASO (Saudi Standards, Metrology and Quality Organization) and GSO (Standardization Organization

    for GCC). GSO 33; Plastic Conduits and Fittings for elctrical installations.BC Conduit UPVC materials used and tested in accordance with the British Standards (BS 4607: Part 1

    and BS 476: Part 7).

    IEE Wiring Regulations: Bahra System complies with all the relevant requirement of the latest edition

    of the BS 7671 (IEE Wiring Regulations).

    Product Certifications and ApprovalsBC Conduit is registered for ISO 9001, certified by American Systems Registrar (ASR).

    BC Conduit is certified for European Product Safety for the following products:

    • Medium, heavy and extra heavy duty grade type conduits Ref. 1301827• Fittings and accessories for conduits Ref. 1313493

    • Junction Boxes Ref. 1313485

    BC Conduit satisfies provisions for CE marking, according to Low Voltage Directive 2006/95/EC.

    BC Conduit’s conduits & accessories are resistant to external influences according to following IP Codes:

    • Extra Heavy duty conduits and accessories IP66

    • Heavy and Medium duty conduits and accessories IP55

    • Junction Boxes IP50

    2

  • 8/20/2019 Bc Conduit Catalog

    6/34

    BC CONDUITMATERIAL SPECIFICATIONS

    BC CONDUIT MATERIAL PROPERTIES

    Thermal Properties All BC Conduit UPVC products are planned to hold local thermal expansion. Fitting procedures andinstruction required to deal with the different movement at the interface with the building fabric.

    Coefficient of linear expansion(Conduits) : 5.5 x 10-5 per C (5mm/3000mm with a temp. rise of 25oC).Coefficient of linear expansion (Trunking) :23 x 10-6 per C (1mm/m for 40oC rise).Operating Temperature : -5oC to 60oC (Minimum and Maximum Temperature)

     Vicat Softening Point: 81oCThermal Conductivity : 0.19W/m/k 

    Chemical PropertiesBC Conduit UPVC(Chemical Resistance) is non corrosive (corrosive free) & not affected by sea water. It

    has excellent resistance to mineral acids, alkalines and detergents, good resistant to alcohols , but liableto attack from solvents such as ketones, aromatics and hydrocarbons.* Corrosion only occur, to any extent when ph is less than 3 or greater than 9.

    Mechanical PropertiesBC Conduit UPVC products (Impact Resistance under normal climatic conditions, BS EN 50086 or itsreplacement IEC 61386-21 (formerly BS 6099)).

    Electrical PropertiesBC Conduit UPVC products are non conductive.Dielectric Strength : 40 kV/mm in DBP Resistivity : 1014 Ωcm  17 kV/mm in Tx oil Resistance to 0.03 ohm rnm²-/m

     Workability, Durability & Maintenances All BC Conduit UPVC products are light weight and can be readily cut & drilled with hand tools. Shortcomponent length can be readily included, reducing wastage of material. The covers & accessories aremanufactured under fine tolerances to ensure a tight fit with ease of removal. Also can be cleaned with

     wet cloth & household detergents (neutral 5/7 pH value), possible to decorate also with commercialpaint. Resistant to staining. Stop ends are tenable to the carriers. All BC Conduit products can maintainedtheir high performance characteristics and stable.

    3

  • 8/20/2019 Bc Conduit Catalog

    7/34

    BC CONDUITTECHNICAL

    BC CONDUIT AND FITTINGS

    Description:BC Conduit high impact UPVC conduit offers a cost effective solution for both new and renovationscontracts. The conduit available in sizes each with 4 different grades. The wide ranges of our fittings& supplementary products resources that almost any installation can be specified with confidence. Theconduits of BC Conduit easily cut using hacksaw or snips due to its light weight and also bent colddue to its smaller sizes. Thanks to these advantages, installation will be 50% quicker than using steel.Modification and repairs are quicker and simpler to be done.

    Features:• Wide ranges of section and sizes.• 4 Grades of round conduit to suit various site situation.• Quicker, simpler and fast installation.

    • Very wide ranges of component maximize versatile applications.• Round, oval and corrugated divisions are compatible.

    Mechanism:Below is a list of available mechanism by name only:- Heavy Gauge Couplings- Bell Mouth Bushes/Sleeves- Expansion Couplings- Male/Female Bushes- Inspection Couplings- Plugs- Strap Saddles- Reducers

    - Quickfit Spacer Saddles- Locknuts- Spacer Bar Saddles- Lockrings- Spring Clip Saddles- Adaptors- Conduit Clips- Bending Springs

    - Quickfit Inspection Elbows- Normal Bends- Quickfit Inspection Tees- Compression Glands- Inspection Tees- Inspection Elbows

    Boxes and AccessoriesBelow is a list of available boxes & accessories by name only.- Circular Boxes- Tee Boxes- Terminal Boxes

    - Intersection Boxes- Through Boxes- Tangent Boxes

    - Branch Boxes- Heat Resistant Boxes- Angle Boxes

    4

  • 8/20/2019 Bc Conduit Catalog

    8/34

    BC CONDUITTECHNICAL

    BOXES AND ACCESSORIES

    CONDUIT (ROUND SECTION HEAVY GAUGE HIGH IMPACT)

     Accessories

    - Extension Rings - BC Conduit Solvent Cement- Steel Insert Clip - BC Conduit Snip Cutter 

    - Earthing Ring - Nylon Draw Tape

    - Brass Earthing Terminals

    Conduit Boxes

    - Adaptable Boxes - Bahra Earth Electrode Box 

    - Square Junction Boxes - Bahra Circular Lids and Gaskets

    Switches and Socket Boxes

     (The wide ranges are available in different depths with assorted of knockouts points). Observe the table

    at the conclusion of this technical sector.

    For classic conduit installation this provides a high degree of fortification or safety.

    Temperature range: -5OC to 60OC (Minimum and Maximum), complies with BS 6099 section 2.2

    Heavy Mechanical Stress (Section 2.2) complies with all related requirements of 16th edition of IEE

     Wiring Regulation and provides high degree of fortification or safety.

    Cable Capabilities of Conduit

    The technique which can be used to establish the size of conduit or trunking required to hold cables

    of the same size, or different sized. The number of cables arrange in an enclosure of a wiring system

    shall be such that no damage is caused to the cables or to the enclosure during their installation. The

    process employs a unit system, each cable size being allocated a part. The sum of all parts for the cables

    intended to be run in the same enclosure is evaluate against the parts given for the conduit in order to

    decide the size of the conduit required to hold those cables.

    Note: Standard Length 2.9 meters

    Outside W.Thickness Weight Cross Section

    θ (mm) (mm) (kg/m) Area(mm²)

    20 1.8 0.150 209

    25 1.9 0.205 350

    32 2.5 0.322 573

    38 2.5 0.394 859

    50 3.2 0.684 1506

    5

  • 8/20/2019 Bc Conduit Catalog

    9/34

    BC CONDUITTECHNICAL

    Types of RunIt has been required for conduit to distinguish the run exceed 2.9m (the run not exceeding 2.9 metersin length) and runs of any length put in bend or sets as:

    1. Straight Run not exceeding 2.9 meters in length.2. Straight Run exceeding 2.9 meters in length.

    (The word “Bend” signifies a British Standard 90o Bend and one double set is equivalent to one bend)

    Case 1. Each conduit size is represented by only one part.Case 2. Each conduit size has a inconsistent part which is dependent on the length of run and thenumber of bends or Expansion Couplings. For a certain size of cables the part allocated to case 1 is notthe same as case 2 above.

     Variable Factors (Inconsistent Part) Different variable parts affect the effort to arrive at a standardmethod of evaluating the capability of conduit. Some of these are the following:- Tolerance in cables sizes - Reasonable Care (of drawing in)

    - Tolerance in conduit - Acceptable use of the space available

    15 YEARS GUARANTY

    BC Conduit shall guaranty and warranty the supplied UPVC conduits and accessories for a period of 15years for indoor use only, from the date of delivery against the products malfunction due to material,

     workmanship and manufacturing defects. 

    BC Conduit guaranty and warranty shall not apply if the customer uses or installs the products improperly, when such an improper use is judged using the national and /or internationally recognized standardsand codes of the electrical Industry.

    The Guaranty shall not extend to items not manufactured by BC Conduit, or to any damages or defectsresulting from the use of products in a manner other than what these intentionally designed for, nor themishandling or misuse during their transport or storage.

    Conduits, Grades, Area and WeightsBC conduits are manufactured and tested as per IEC / EN 61386 (previously BS 6099) to withstand a

     wide range of impact and compression forces starting with Medium Duty (3321) for flush and serviceapplications, Heavy Duty (4421) for ceiling and wall installations, and Extra Heavy Duty (5521) forinstallation inside bulk concrete in temperature range of -5oC to 60oC.

    The following table shows the Nominal Dimensions of each type:

    * Extra Heavy Duty also available.

    Medium Heavy Medium Heavy Extra Heavy  

    OutsideDiameter (mm)

    Nominal Thickness (mm) Internal Area (mm2)

    20 1.6 1.8 222 211 206

    25 1.8 1.9 360 353 327

    32 2.1 2.5 607 573 552

    38 2.2 2.5 887 855 804

    50 2.5 3.2 1590 1493 1439

    6

  • 8/20/2019 Bc Conduit Catalog

    10/34

    IEC, BRITISH & EUROPEAN SYSTEMTECHNICAL INFORMATION

    IEC, BS & EN STANDARDS

  • 8/20/2019 Bc Conduit Catalog

    11/34

    TECHNICAL INFORMATIONIEC, BS & EN STANDARDS

    CABLE CAPACITIES OF CONDUITS(Based on Appendix 12 IEE Regulations 17th Edition to the latest edition)

    1. For each cable it is intended to use obtain the appropriate cable factor.

    2. Add all the cable factors so obtained and compare with the factors for conduit/trunking.

    3. The size of trunking/conduit which will satisfactorily accommodate the cables is that size

    having a factor equal to or exceeding the sum of the cable factors.

    Single core UPVC insulated cables in straight runs of conduit not exceeding 3m in length

    Single UPVC insulated cables in straight runs of conduit exceeding 3m in length or in runs of any length

    incorporating bends or sets

    Type of Conductor 

    Cable Factor Conduit Factor  

    Conductor Cross

    Sectional Area(mm²) Factor Conduit

    Diameter (mm) Factor 

    Solid

    1 22 16 290

    1.5 27 20 460

    2.5 39 25 800

    32 1400

    Stranded

    1.5 31

    2.5 43

    4 58

    6 88

    10 146

    Type of Conductor  Conductor Cross Sectional

     Area (mm²)

    Factor 

    Solidor 

    Stranded

    1 16

    1.5 22

    2.5 30

    4 43

    6 58

    10 105

    4 58

    8

  • 8/20/2019 Bc Conduit Catalog

    12/34

    FIXING According to IEE regulations the following table shows the recommended distances between fixings.

    Distance between fixings for conduit

    TECHNICAL INFORMATIONIEC, BS & EN STANDARDS

    ConduitSize in

    mm

    Maximum distance between fixings in meters

    Metal Plastic Pliable

    Horizontal Vertical Horizontal Vertical Horizontal Vertical

    16 0.75 1 0.75 1 0.3 0.5

    20 1.75 2 1.5 1.75 0.4 0.6

    25 1.75 2 1.5 1.75 0.4 0.6

    32&38 2 2.25 1.75 2 0.6 0.8

    Over 40 2.25 2.5 2 2 0.8 1

    9

  • 8/20/2019 Bc Conduit Catalog

    13/34

    IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM

  • 8/20/2019 Bc Conduit Catalog

    14/34

    HEAVY DUTY UPVC CONDUIT *

    IEC CODE 4421 1250N

    EXTRA HEAVY DUTY UPVC CONDUIT *IEC CODE 5521 4000N

    ItemCode

    NominalSize

    (O.D.)

    MinimumInside

    Diameter 

     WallThickness

    StandardPacks

    BulkPacks

    mm mm mm Pcs Mtrs Pcs

    BSP 2 20 16.0 1.8 50 145 4550

    BSP 3 25 20.7 1.9 40 116 2880

    BSP 4 32 26.5 2.5 20 58 1800

    BSP 5 38 32.5 2.5 20 58 1300

    BSP 6 50 43.0 3.2 10 29 720

    ItemCode

    NominalSize (O.D.)

    MinimumInside

    Diameter 

    StandardPacks

    BulkPacks

    mm mm Pcs Mtrs Pcs

    BEP 2 20 15.2 50 145 4550

    BEP 3 25 19.7 40 116 2880

    BEP 4 32 26.3 20 58 1800

    BEP 5 38 32.0 20 58 1300

    BEP 6 50 43.1 10 29 720

    Available in 2 colors: Black and White. When ordering use color suffix BK WT

    Available in 2 colors: Black and White. When ordering use color suffix BK WT

    11

    2006/95/ECLow Voltage Directive

    IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM

    * Manufactured According to BS 6099, EN 61386 (IEC 61386), Standard length 2.9m.  Other lengths available on request

    Ref: 1301827

  • 8/20/2019 Bc Conduit Catalog

    15/34

    MEDIUM DUTY UPVC CONDUIT *IEC CODE 3321 750N

    LIGHT DUTY UPVC CONDUIT *IEC CODE 2221 320N

    ItemCode

    NominalSize

    (O.D.)

    MinimumInside

    Diameter 

     WallThickness

    StandardPacks

    BulkPacks

    mm mm mm Pcs Mtrs Pcs

    BMP 2 20 16.5 1.6 50 145 4550

    BMP 3 25 20.9 1.8 40 116 2880

    BMP 4 32 27.3 2.1 20 58 1800

    BMP 5 38 33.1 2.2 20 58 1300

    BMP 6 50 44.4 2.5 10 29 720

    ItemCode

    NominalSize

    (O.D.)

    MinimumInside

    Diameter 

     WallThickness

    StandardPacks

    BulkPacks

    mm mm mm Pcs Mtrs Pcs

    BLP 2 20 17.2 1.2 50 145 4550

    BLP 3 25 21.7 1.4 40 116 2880

    BLP 4 32 28.5 1.5 20 58 1800

    BLP 5 38 34.5 1.5 20 58 1300

    BLP 6 50 45.6 1.9 10 29 720

    * Manufactured According to BS 6099, EN 61386 (IEC 61386), Standard length 2.9m.  Other lengths available on request

    Available in 2 colors: Black and White. When ordering use color suffix BK WT

    Available in 2 colors: Black and White. When ordering use color suffix BK WT

    12

    2006/95/ECLow Voltage Directive

    IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM

    Ref: 1301827

  • 8/20/2019 Bc Conduit Catalog

    16/34

    STANDARD COUPLING

    EXPANSION COUPLING

    BENDS-HEAVY GAUGE WITH BELL ENDS

    BENDS-HEAVY GAUGE WITH COUPLINGS

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BSC 2 20 100 20,000

    BSC 3 25 100 10,000

    BSC 4 32 25 5,000

    BSC 5 38 25 2,500

    BSC 6 50 20 2,000

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BEC 2 20 50 800

    BEC 3 25 25 625

    BEC 4 32 20 260

    BEC 5 38 10 250

    BEC 6 50 10 120

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BLB 2 20 30 3,000

    BLB 3 25 15 1,500

    BLB 4 32 100 600

    BLB 5 38 60 360

    BLB 6 50 25 150

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BNB 2 20 30 3,000

    BNB 3 25 15 1,500

    BNB 4 32 100 600

    BNB 5 38 60 360

    BNB 6 50 25 150

    2006/95/ECLow Voltage Directive

    IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM

    All above products available in 2 colors: Black and White. When ordering use color suffix BK WT

    Ref: 1313493

    13

  • 8/20/2019 Bc Conduit Catalog

    17/34

    ROUND SPRING CLIPS

    FEMALE ADAPTORS

    MALE ADAPTORS

    MALE THREADED BUSH

    FEMALE THREADED LOCKRINGS

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BCC 2 20 200 5200

    BCC 3 25 100 4000

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BFA 2 20 100 20,000

    BFA 3 25 100 10,000BFA 4 32 25 5,000

    BFA 5 38 25 5,000

    BFA 6 50 20 3,000

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BMA 2 20 100 20,000

    BMA 3 25 100 20,000

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    TBM 2 20 100 20,000

    TBM 3 25 100 20,000

    TBM 4 32 100 2600

    TBM 5 38 50 2000

    TBM 6 50 25 1000

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    TLF 2 20 100 20,000

    TLF 3 25 100 20,000

    2006/95/ECLow Voltage Directive

    IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM

    All above products available in 2 colors: Black and White. When ordering use color suffix BK WT

    Ref: 1313493

    14

  • 8/20/2019 Bc Conduit Catalog

    18/34

    INSPECTION ELBOWS

    INSPECTION BENDS

    INSPECTION TEES

    STRAP SADDLES

    SADDLE WITH BASE

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BIE 2 20 25 650

    BIE 3 25 25 400

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BIB 2 20 25 400

    BIB 3 25 20 320

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BIT 2 20 20 520

    BIT 3 25 20 320

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BPS 2 20 200 40,000

    BPS 3 25 200 40,000

    BPS 4 32 100 20,000

    BPS 5 38 25 2000

    BPS 6 50 25 1300

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BSB 2 20 100 20,000

    BSB 3 25 100 20,000

    BSB 4 32 100 10,000

    BSB 5 38 25 1000

    BSB 6 50 25 650

    IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM

    All above products available in 2 colors: Black and White. When ordering use color suffix BK WT

    15

  • 8/20/2019 Bc Conduit Catalog

    19/34

  • 8/20/2019 Bc Conduit Catalog

    20/34

     ANGLE – TWO WAY BOX

    TEE – THREE WAY BOX

    INTERSECTION – FOUR WAY BOX

    U – TWO WAY BOX

     Y – THREE WAY BOX

    H – FOUR WAY BOX

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/4 20 25 2,500

    3/BRB/4 25 25 2,500

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/5 20 20 2,000

    3/BRB/5 25 20 2,000

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/6 20 20 2,000

    3/BRB/6 25 20 2,000

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/12 20 25 2,500

    3/BRB/12 25 25 2,500

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/13 20 25 2,500

    3/BRB/13 25 25 2,500

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/14 20 25 2,500

    3/BRB/14 25 25 2,500

    2006/95/ECLow Voltage Directive

    IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM

    All above products available in 2 colors: Black and White. When ordering use color suffix BK WT

    Ref: 1313485

    17

  • 8/20/2019 Bc Conduit Catalog

    21/34

    CIRCULAR LIDS

    RUBBER GASKET

    CIRCULAR JUNCTION BOXES FITTED WITH RUBBER GASKET, LID & SCREWSCircular Junction Boxes Fitted With Rubber Gasket, Lid & Screws - Circular Boxes can be suppliedassembled with rubber gasket, lid & screws. E.g. Item codes for 20mm 2 way through circular junctionbox DJT 2 should be suffixed with/RG as DJT 2/RG

    Heavy Gauge springs are suitable for heavy & medium gaugeround conduits while light gauge springs are suitable for lightgauge round conduits

    BENDING SPRINGS

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BSL 2 15 200 40,000

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    BRG 66 100 2600

    HeavyGauge

    Item Code

    ConduitSize (mm)

    Light GaugeItem Code

    Bulk Packs

    BSS H2 20 BSS L2 -

    BSS H3 25 BSS L3 -

    UPVC CEMENT

    Item Code Size (ml) Standard Packs Bulk Packs (Pcs)

    BSG 1 118 48 -

    BSG 2 237 24 1008

    BSG 3 473 12 600

    BSG 4 946 6 -

     Available in 118ml, 237ml, 473ml and 946ml cans with applicator.Suitable for use with BC UPVC conduit, trunking & fittings.

    Available in 2 colors: Black and White. When ordering use color suffix BK WT

    IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM

    18

  • 8/20/2019 Bc Conduit Catalog

    22/34

    TERMINAL ONE WAY & BACK OUTLET

    THROUGH TWO WAY & BACK OUTLET

     ANGLE TWO WAY & BACK OUTLET

    TEE THREE WAY & BACK OUTLET

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/7 20 20 3,000

    3/BRB/7 25 20 3,000

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/8 20 20 3,000

    3/BRB/8 25 20 3,000

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/9 20 20 3,000

    3/BRB/9 25 20 3,000

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/10 20 20 3,000

    3/BRB/10 25 10 1,500

    IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM

    All above products available in 2 colors: Black and White. When ordering use color suffix BK WT

    2006/95/ECLow Voltage Directive

    Ref: 1313485

    19

  • 8/20/2019 Bc Conduit Catalog

    23/34

    INTERSECTION FOUR WAY & BACK OUTLET

    U- TWO WAY & BACK OUTLET

     Y-THREE WAY & BACK OUTLET

    H FOUR WAY & BACK OUTLET

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/11 20 10 1,500

    3/BRB/11 25 10 1,500

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/15 20 20 3,000

    3/BRB/15 25 20 3,000

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/16 20 20 3,000

    3/BRB/16 25 10 1,500

    Item Code Size (mm) Standard Packs Bulk Packs (Pcs)

    2/BRB/17 20 10 1,500

    3/BRB/17 25 10 1,500

    IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM

    All above products available in 2 colors: Black and White. When ordering use color suffix BK WT

    2006/95/ECLow Voltage Directive

    Ref: 1313485

    20

  • 8/20/2019 Bc Conduit Catalog

    24/34

     ADAPTABLE BOX

     WIRE PULLER 

    Item Code Size (mm) Standard Packs

    BAB 1 100x100x60 150

    BAB 2 130x130x74 28

    BAB 3 215x215x110 10

    Item Code Diameter (mm) Size (meter)

    BWP 1 4.5 15

    BWP 2 4.5 30

    Available in Grey color only

    Available in White color only

    IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM

    21

  • 8/20/2019 Bc Conduit Catalog

    25/34

    AMERICAN SYSTEMTECHNICAL INFORMATION

    AMERICAN STANDARDS

  • 8/20/2019 Bc Conduit Catalog

    26/34

    TECHNICAL INFORMATION AMERICAN STANDARDS

    BC American Standard Conduits:

    UPVC Material

    Manufacturing Standards

    Heavy wall and extra-heavy wall rigid plastic (UPVC) conduit, fittings and accessories designed for

    installation underground, in slab, encased or light weight, high-impact strength and low installationcosts. Supplied in standard 10’ lengths, with or without belled ends.

    Encased in concrete or direct burial for underground applications, also for exposed or concealed

    applications aboveground. Sunlight resistant, rated for use with 90°C conductors, reduced smoke and

    HCL emissions, superior weathering characteristics.

    Specifications: UL type 40 rated for 90°C cable can be used in above ground or below ground applications

    subject to severe physical abuse.

    Rigid UPVC Compound which fully meets the material requirements of American specifications for cellas per ASTM D 1784 and ASTM D 4396 as specified in NEMA Standards.

    NEMA TC 2 Electrical Plastic Tubing (EPT) and Conduit (EPC-40 and EPC-80)

    NEMA TC 6 UPVC Plastic Utilities Duct for underground installation

    &

    NEMA TC 8 Extra-Strength UPVC Plastic Utilities Duct for underground installation

     ASTM F 512 Smooth-wall UPVC Conduit and fittings for underground installation

    23

  • 8/20/2019 Bc Conduit Catalog

    27/34

    TECHNICAL INFORMATION AMERICAN STANDARDS

    UPVC PROPERTIES

    PROPERTY ASTM TEST METHOD UNIT VALUE

    General Properties:

    Density D-792 g/cm³ 1.44 0.02

     Water Absorption D-570/Proc. A % 0.3

    Mechanical Properties:

    Tensile Strength, Ultimate D-638/Type 1 kg/cm² 421.1

    Modulus of Elasticity D-638/Type 1 Mpa 1930

    Flexural Strength D-695, D-790/Proc. B Mpa 77

    Hardness D-785 Shore D 119

    Izod Impact Strength D-256/method A J/M 34.7Thermal Properties:

    Heat Deflection Temp. D-648 (1.82 Mpa load) °C/ (°F) > 70(158)

     Vicat Softening Temp. D-1525 (rate A) °C/ (°F) > 70(158)

    Co-efficient of ThermalExpansion

    D-696/3m length mm/m/10°C 1.6

    Thermal Conductivity C-177 W/(°Km) 0.14

    Flammability Properties:

    Flammability D-635 Resistance Self extinguishing

    Extent of Burning D-635 mm

  • 8/20/2019 Bc Conduit Catalog

    28/34

    AMERICAN SYSTEMAMERICAN CONDUIT SYSTEM

  • 8/20/2019 Bc Conduit Catalog

    29/34

     AMERICAN SYSTEM AMERICAN CONDUIT SYSTEM

    RIGID UPVC CONDUITSNEMA TC 2 “Electrical Polyvinyl Chloride (UPVC) Conduit” Schedule 40

    Item CodeTradeSize

    (inch)

    MetricDesignators

     Averageoutside

    diameter mm

    SCH-40

    StandardPacks

    BulkPacks(Pcs)

     WallThickness(Min.) mm

    Nominal Weight

    Kg/m

    BAC/105 ½ 16 21.34 2.77 0.248 40 3,640

    BAC/107 ¾ 21 26.67 2.87 0.329 30 2,160

    BAC/110 1 27 33.40 3.38 0.483 20 1,440

    BAC/112 1¼ 35 42.16 3.56 0.652 20 900

    BAC/115 1½ 41 48.26 3.68 0.779 10 720

    BAC/120 2 53 60.32 3.91 1.04 10 450

    BAC/130 3 78 88.9 5.49 2.16 - -

    BAC/140 4 103 114.3 6.02 3.07 - -

    BAC/160 6 155 168.28 7.11 5.41 - -

    26

  • 8/20/2019 Bc Conduit Catalog

    30/34

    27

     AMERICAN SYSTEM AMERICAN CONDUIT SYSTEM

    RIGID UPVC CONDUITSBS 3506-1969 Class-B 6.0 bar 

    Item CodeTradeSize

    (inch)

    Mean Outside Diameter 

     Average Value

    Max 

    Individual Value

    Min Max   Minmm

    Max mm

    BIP/130 3 88.7 89.1 3.4 2.9 3.4

    BIP/140 4 114.1 114.5 4 3.4 4

    BIP/150 5 140.0 140.4 4.4 3.8 4.4

    BIP/160 6 168.0 168.5 5.2 4.5 5.2

    COUPLING

    Item Code Size (inch) Standard Packs Bulk Packs (Pcs)

    BSC/105 1/2 100 20,000

    BSC/107 3/4 100 10,000

    BSC/110 1 50 5,000

    BSC/112 11/4 25 2,500

    BSC/115 11/2 25 2,500

    BSC/120 2 20 2,000

  • 8/20/2019 Bc Conduit Catalog

    31/34

     AMERICAN SYSTEM AMERICAN CONDUIT SYSTEM

    90O ELBOW - PLAIN END

    90O ELBOW - BELL ONE END

    90O ELBOW - BELL TWO ENDS

    Schedule 40

    Schedule 40

    Schedule 40

    28

    Item Code Size (in) Standard Packs Bulk Packs (Pcs)

    BEPC2 1/2 20 2,000

    BEPC3 3/4 10 1,000

    BEPC4 1 100 600

    BEPC5 11/4 50 300

    BEPC6 11/2 50 300

    BEPC7 2” 25 150

    Item Code Size (in) Standard Packs Bulk Packs (Pcs)

    BEPC2/1S 1/2 20 2,000

    BEPC3/1S 3/4 10 1,000

    BEPC4/1S 1 100 600

    BEPC5/1S 11/4 50 300

    BEPC6/1S 11/2 50 300

    BEPC7/1S 2” 25 150

    Item Code Size (in) Standard Packs Bulk Packs (Pcs)

    BEPC2/2S 1/2 20 2,000

    BEPC3/2S 3/4 10 1,000

    BEPC4/2S 1 100 600

    BEPC5/2S 11/4 50 300

    BEPC6/2S 11/2 50 300

    BEPC7/2S 2” 25 150

  • 8/20/2019 Bc Conduit Catalog

    32/34

    15 YEAR GUARANTY

    BC Conduit shall guaranty and warranty the supplied UPVC conduitsand accessories for a period of 15 years for indoor use only, from thedate of delivery against the products malfunction due to material,

     workmanship and manufacturing defects. BC Conduit guaranty and warranty shall not apply if the customeruses or installs the products improperly, when such an improperuse is judged using the national and /or internationally recognizedstandards and codes of the electrical Industry.

    The Guaranty shall not extend to items not manufactured by BCConduit, or to any damages or defects resulting from the use ofproducts in a manner other than what these intentionally designedfor, nor the mishandling or misuse during their transport or storage.

    5107

    29

  • 8/20/2019 Bc Conduit Catalog

    33/34

     AluminumFactory 

    Pre CastFactory 

    for Concrete

    TrainingInstitute

    for Technology 

    Roundabout

        M   A     K     K    A     H

         R    O   A     D

              T      o           M

          a           k           k

          a           h

    To Makkah

           T    o

           J    e      d      d

        a       h

    B a h r a  F l  y o v e r 

    PREMCO

       N

    INDUSTRIAL PARK 

    K ing  A bdul A z iz Medic al Cit y 

  • 8/20/2019 Bc Conduit Catalog

    34/34