75
CONTROL BOARD BD300FD-24-BX SPECIFICATION AND OPERATION MANUAL

Bd300fd 24 Bxcontrolboardspecification Operationmanual

Embed Size (px)

DESCRIPTION

control impressora

Citation preview

Page 1: Bd300fd 24 Bxcontrolboardspecification Operationmanual

CONTROL BOARDBD300FD-24-BX

SPECIFICATIONAND

OPERATION MANUAL

Page 2: Bd300fd 24 Bxcontrolboardspecification Operationmanual

NOTICE• All rights reserved. Reproduction of any part of this manual in any form whatsoever,without

STAR's express permission is forbidden.

• The contents of this manual are subject to change without notice.

• All efforts have been made to ensure the accuracy of the contents of this manual at the timeof going to press. However, should any errors be detected, STAR would greatly appreciatebeing informed of them.

• The above notwithstanding, STAR can assume no responsibility for any errors in this manual.

©Copyright 1991,2000 Star Micronics Co., LTD.

Page 3: Bd300fd 24 Bxcontrolboardspecification Operationmanual

CONTENTS

1. GENERAL DESCRIPTION .............................................................................................. 11.1 Overview ................................................................................................................... 11.2 Features ..................................................................................................................... 1

2. MAIN SPECIFICATIONS ................................................................................................ 2

3. CONFIGURATION ............................................................................................................ 33.1 Block Diagram .......................................................................................................... 33.2 Connector Assignment Diagram ............................................................................... 53.2 Connector Specifications and Signal Names ............................................................ 5

3.3.1 CN1 (Print Head Drive Signals) .................................................................. 53.3.2 CN2 (Printer Control Signals) ..................................................................... 63.3.3 CN3 (Paper Out Signals) ............................................................................. 63.3.4 CN5 (Paper Winder Signals) ....................................................................... 73.3.5 CN6 (Paper Cutter Signals) ......................................................................... 73.3.6 CN7 (Peripheral Drive Signals)................................................................... 83.3.7 CN8 (Serial Interface) ............................................................................... 103.3.8 CN9 (Optional Interface Board) ................................................................ 123.3.9 CN10 (Control Panel Signals) ................................................................... 133.3.10 CN1l (Power Supply) ............................................................................... 16

4. CONNECTION AND SETTINGS .................................................................................. 174.1 Connecting the Power Supply and Connectors ....................................................... 174.2 INterface Connections ............................................................................................. 184.3 Setting the Jumper ................................................................................................... 184.4 Setting the DIP switches ......................................................................................... 19

4.4.1 DIP switch1 ............................................................................................... 194.4.2 DIP switch2 ............................................................................................... 194.4.3 DIP switch3 ............................................................................................... 204.4.4 DIP switch4 ............................................................................................... 20

5. INTERFACE ..................................................................................................................... 215.1 Interface Specifications ........................................................................................... 215.2 Interface Timing ...................................................................................................... 21

5.2.1 RS-232C .................................................................................................... 215.2.2 Current Loop (Option) ............................................................................... 225.2.3 RS-422A Serial I nterface (Option) ........................................................... 22

Page 4: Bd300fd 24 Bxcontrolboardspecification Operationmanual

6. CONTROLCODES .......................................................................................................... 236.1 Control Codes Used for Character Setting .............................................................. 236.2 Control Codes Used for Line Spacing .................................................................... 286.3 Control Codes Used for Page Layout ...................................................................... 296.4 Control Codes Used for Graphics Printing ............................................................. 326.5 Control Codes Used for Download Characters ....................................................... 366.6 Control Codes Used for Peripheral Units ................................................................ 396.7 Other Control Codes ............................................................................................... 40

7. DATA STRUCTURE ........................................................................................................ 447.1 DTR Mode .............................................................................................................. 447.2 X-ON/X-OFF Mode ................................................................................................ 467.3 STX-ETX Mode ...................................................................................................... 48

8. PC BOARD, CIRCUIT DIAGRAM, PARTS LIST ...................................................... 508.1 PC Board Dimension Drawing................................................................................ 508.2 Component Layout .................................................................................................. 518.3 Circuit Diagram ....................................................................................................... 528.4 Parts List .................................................................................................................. 56

9. APPENDIX ................................................................................................................... 599.1 Control Code List .................................................................................................... 599.2 Character Code Table............................................................................................... 62

9.2.1 U.S.A & Europe ......................................................................................... 629.2.2 IBM Character Set #1 ................................................................................ 649.2.3 IBM Character Set #2 ................................................................................ 669.2.4 Japan .......................................................................................................... 689.2.5 International Character Sets ...................................................................... 70

Page 5: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 1 –

1. GENERAL DESCRIPTION1.1 Overview

1.2 Features

The BD300FD-24-BX Control board is a dedicated circuit board designed for driving the MP300 series printer

mechanisms. It consists of the control circuits that control the motor, print head, and other mechanisms; an

interface circuit for exchanging signals with a personal computer or other host; and other circuits. Its interface

conforms to the RS-232C. By simply providing a power supply, the user can employ a personal computer or

other host to easily drive the printer mechanism.

(1) Model Name Notation

(2) Applicable Printer Mechanisms

Applicable Printer Mechanisms Remarks

MP312F-24-A 40 columns

MP312FV-24-A 40 columns, Validation functions provided

MP342F-24-A 40 columns, Paper cutter provided

MP311F-24-A 28 columns

MP341F-24-A 28 columns, Paper cutter provided

(1) The built-in serial intergface conforms to tne RS-232C.

(2) The resident data buffer has a storage capacity of about 4 Kbytes, enabling data to be received even

while printing.

(3) Commands are available for printing expanded, inverted, emphasized, highlighted characters, and so on.

There is thus a wide selection of characters to choose.

B D 3 0 0 F D - 24 - B X

Voltage

24: 25VDC, 5VDC

Interface and Connector type

C: Ser ia l Interface D-Sub 25pin Connector

Paper feeding method for applicableprinter machanism

F: Fr ict ion feed

Page 6: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 2 –

2. MAIN SPECIFICATIONS

Applicable printers See “(2) Applicable Printer Mechanisms” in section 1.1.

Interface Conforms to the RS-232C,20mA Current Loop (Optional),RS-422A (Optional)

Power supply 25VDC, 5VDC

Configuration See the block diagram in Fig. 3-1.

No. of characters See section 9.2, “Character Code Tables.”

96 ASCII characters, 50 IBM block graphics

64 special characters, 64 katakana (Japanese) characters

64 block graphics, 12 international characters

64 IBM special characters, 10 user-definable (download) characters

Font matrices Normal characters 5 × 9 7 × 9 (half-dot)

Block graphics 6 × 6 5 × 6

IBM block graphics 6 × 12 5 × 12

No. of commands 68 types (see Chapter 6)

External dimensions 150 × 166 mm

Weight approx. 160 g (cable assembly excluded)

Operating environment Temperature 0˚C to +50˚C

Humidity 10% to 80% RH (at +40˚C without condensation)

Storage environment Temperature -20˚C to +70˚C

Humidity 5% to 95% RH (at +40˚C without condensation)

Page 7: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 3 –

3. CONFIGURATION3.1 Block Diagram

(1) Control Board

The data output from the host computer passes through the control board’s interface then is stored in

RAM by the CPU.

Next, the CPU reads the data stored in RAM and edits it according to the program stored in ROM.

When editing is completed, the CPU outputs various drive signals to the printer mechanism to execute

printing.

[Description of each component]

a. CPU TMP90C041: CMOS-structured single-chip microcomputer

Performs overall control of the printer.

b. EPROM 27256: 32 Kbytes

Stores the program used for control by CPU.

c. RAM 6264: 8 Kbytes

Is used as the stack area and work area by the CPU and as the data buffer.

d. Serial interface circuit

Transfers serial data with the host computer.

e. Gate array

Performs input, output, and conversion of various signals.

f. Driver

Converts the signals output from the CPU or gate array into drive signals to drive the printer

mechanism.

Fig. 3-1 Block Diagram

Control panel board

CPU

Control board

Data (from host computer)

Serialinterface Driver

Gate array

EPROM 32KB

RAM 8KB

Driver

Paper Out detector

25VDC 5VDC

Print head

PeripheralUnit

Carriage motor

Paper feed motor

Detectors

Printer mechanism

Page 8: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 4 –

(2) Control Panel

The control panel is used to manually operate the printer.

(3) Printer Mechanism

The printer mechanism consists of the print head, carriage motor, paper feed motor, and detectors.

(4) Paper Out Detector

The paper out detector detects whether a paper is set or not.

(5) Peripheral Unit

After receiving the driving signal from the control board, peripheral units (such as cash drawers) are

activated.

Page 9: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 5 –

Board connector HLEM14S-1 [FCI]

Applicable cable set Cable Unit 14 × 265 SP312 (Optional)

3.3 Connector Specificarions and Signal Names

3.3.1 CN1(Print Head Drive Signals)

3.2 Connector Assignment Diagram

Cable SMCD-14× 265-AD×10-P1.25-S6-M-K, UL2896 (Sumitomo Electric Industries, Ltd.)

Pin No. Signal Name Function Pin No. Signal Name Function

1 HD #2 Head solenoid 2 8 HD CMN3 Head common 3

2 HD #4 Head solenoid 4 9 THERMISTOR Thermistor

3 HD #1 Head solenoid 1 10 HD #9 Head solenoid 9

4 HD #6 Head solenoid 6 11 THERMISTOR Thermistor

5 HD CMN 1 Head common 1 12 HD #5 Head solenoid 5

6 HD #8 Head solenoid 8 13 HD #3 Head solenoid 3

7 HD CMN 2 Head common 2 14 HD #7 Head solenoid 7

Fig.3-3 Cable Unit 14 × 265 SP312 (Optional)

Fig.3-2 Connector Assignment Diagram

Printer mechanism Control board side

12

14

265±5 mm

Note: An optional U14 × 100 BD300F 100-mm long cable or U14 × 330 BD300F 330-mm long cable isalso available.

6CN7

8

1SW3

CN941

J3

J1 J2

SW4

1

1

8

1 1SW1

8

1SW2 24

SW6SW5CN8

25

8

1CN10

CN5

1 2

CN3

11

3

19 1

14

CN2CN1

CN114

1

CN65

1

Cable Unit 8 × 510C BD300F

(Option)

Cable Unit 19 × 265 SP312(Option)

or Cable Unit 19 × 100 BD300F(Option)

or Cable Unit 19 × 330 BD300F(Option)

Cable Unit 14 × 265 SP312(Option)

or Cable Unit 14 × 100 BD300F(Option)

or Cable Unit 14 × 330 BD300F(Option)

Cable Unit 4 × 510C BD300F

(Option)

Page 10: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 6 –

Board connector 5483-03A [Molex]

Applicable cable set Not supplied with this unit.

3.3.2 CN2(Printer Control Signals)

Board connector HLEM 19S-1 [FCI]

Applicable cable set Cable Unit 19 × 265 SP312 (Optional)

Cable SMCD-19 × 265-AD× 10-P1.25-S6-M-K, UL2896 (Sumitomo Electric Industries, Ltd)

Fig. 3-4 Cable Unit 19 × 265 SP312 (Optional)

Pin No. Signal Name Function Pin No. SignalName Function

1 LF-ø1 LF motor ø1 11 N.C. Not connected

2 LF-ø2 LF motor ø2 12 +5V +5V

3 LF-ø3 LF motor ø3 13 H.P.SIG Home position signal

4 LF-ø4 LF motor ø4 14 VALIDATION Validation signal*l

5 LF-CMN A LF motor common A 15 N.C. Not connected

6 LF-CMN B LF motor common B 16 TIMING SIG 1 Timing signal 1

7,8 MOTOR (+) CR motor (+) 17 TIMING SIG 2 Timing signal 2

9,10MOTOR (-) CR motor (-) 18 S-GND Signal ground

(M-GND) (Motor Ground) 19 N.C. Not connected

*1 The Validation signal is only effective if the MP312FV-24-A Printer Mechanism (which is equipped with

Validation functions) has been mounted.

3.3.3 CN3 (Paper Out Signals)

Pin No. Signal Name Function

1 N.C. Not connected

2 PAPER OUT SIG 1 Paper out signal

3 GND Signal ground

Fig. 3-5 Paper Out Detector Cable

Note: An optional U19 × 100 BD300F 100-mm long cable or U19 × 330 BD300F 330-mm long cable isalso available.

1

3Housing 5480-03A (Molex)Terminal 5479-PBT/PBTZ (Molex)

CLOSE no paper is set

Printer mechanism Control board side

123

19

265 5 mm+-

Page 11: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 7 –

3.3.4 CN5 (Paper Winder Signals)

Board connector 5483-02A [Molex]

Applicable cable set PW300-24 (optional)

Fig. 3-6 PW300-24 Rewinder (Optional)

Pin No. Signal Name Function

1 REWINDER (+) Paper winding (+)

2 REWINDER (-) Paper winding (-)

3.3.5 CN6 (Paper Cutter Signals)

These signals only effect the Printer Mechanism which is equipped with an auto cutter, MP342F-24-A and

MP341F-24-A.

Board connector 5483-05A [Molex]

Applicable cable set Cable Unit 5 × 195 SP342 (Optional)

Fig. 3-7 Cable Unit 5 × 195 SP342 (Optional)

Pin No. Signal Name Function

1 F/P POSIRION SIG F/P Position signal

2 RESET SIG Reset signal

3 GND Ground

4 MOTOR (-) Motor (-)

5 MOTOR (+) Motor (+)

12

Control board side

PW300-24

Housing 5480-02 (Molex)Terminal 5479 PBT/PBTZ (Molex)

Rewinder (option)

Page 12: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 8 –

3.3.6 CN7 (Peripheral Drive Signals)

A drive circuit for driving peripheral units (such as cash drawers) is featured on the control board. A modular

connector for driving peripheral unit is featured on the output side on the drive circuit. When using this circuit,

connect the cable for the peripheral unit. (Cables must be prepared by the user.)

Board connector 6-P Modular Jack Connector

Applicable cable set Cables must be prepared by the user

Use cables which meet the following specifications.

Fig. 3-8 Cable specifications

Pin No. Signal Name Function

1 F-GND Frame ground

2 PERIPHERAL EXT 1 Peripheral unit 1 (-)

3, 4 PERIPHERAL COM Drive Common (+24V)

5 PERIPHERAL EXT 2 Peripheral unit 2 (-)

6 COMPULSION SIG Compulsion signal

Page 13: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 9 –

[Drive output 24V, max. 1.0A]

Notes:

1. Peripheral units 1 and 2 cannot be driven simultaneously.

When the printer has been driven continuously, set the drive duty to maximum 20%.

2. The status of the compulsion switch is available in printer as status data. (Refer to “Chapter 7. Data

structure”.)

3. Resistance values of coils L1 and L2 are minimum 24Ω.

4. Absolute maximum rating of diodes D1 and D2 (Ta = 25˚C)

Average rectified current I0 = 1A

Maximum forward surge current (60Hz, sine wave 1 cycle) IFSM = 40A

5. Absolute maximum rating of transistors TR1 and TR2 (Ta = 25˚C)

Collector current Ic = 2A

Collector loss Pc = 1.2W

6. Shield of cable must be connected to frame of peripheral device to provide static (ESD) drain.

Fig. 3-9 Drive circuit

Page 14: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 10 –

3.3.7 CN8 (Serial Interface)

Board connector D-Sub 25-pin connector

Applicable cable Not supplied with this unit.

RS-232C

Pin no. Signal name I/O Functiondirection

1 F-GND - Frame ground

2 TXD OUT Transmitted data

3 RXD IN Received data

4 RTS OUT Data transmission request signal. This is always “SPACE” when

the control board is turned on.

5 CTS IN This signal changes to “SPACE” when host computer is ready to

transmit data.(In this instance, the control board does not check

this signal.)

6 N.C. Not connected

7 S-GND - Signal ground.

8 N.C. Not connected.

9 to 10 OP-IF This pin is used when using the optional interface board.

11 RCH OUT This signal changes to “SPACE” when the control board is ready

to receive data. (The signal line is same as pin 20.)

12 N.C. Not connected.

13 S-GND - Signal ground

14 FAULT OUT When control board error occurs (such as paper out, mechanical

error), this signal is set to “MARK”.

15 Multi-printer TXD OUT Diode coupled TXD

16 Multi-printer DTR OUT Diode coupled DTR

17 to 19 OP-IF This pin is used when using the optional interface board.

20 DTR OUT Data terminal ready signal. When the control board is ready to

receive data, this signal changes to “SPACE”.

21 to 22 N.C. Not connected

23 to 25 OP-IF This pin is used when using the optional interface board.

Fig. 3-10 Serial interface connector

14

1

25

13

Page 15: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 11 –

When attaching an optional board 20mA current loop or RS-422A to the connector CN9, pins No.9-10, 17-

19 and 23-25 have the following functions.

20mA current loop (option)

Pin no. Signal name I/O Functiondirection

9 TTY TXDR - Indicates the ground side of the data signal of 20mA current loop.

10 TTY TXD OUT Transmitted data of 20mA current loop.

17 TTY TXDR - Indicates the ground side of the data signal of 20mA current loop.

18 TTY RXDR - Indicates the ground side of the data signal of 20mA current loop.

19 TTY RXD IN Received data of 20mA current loop.

23 TTY RXDR - Indicates the ground side of the data signal of 20mA current loop.

24 TTY TXD OUT Transmitted data of 20mA current loop.

25 TTY RXD IN Reception data of 20mA current loop

Pin no. Signal name I/O Functiondirection

9 SD(+) OUT Transmitted data

10 SD(-) OUT Transmitted data

17 RD(+) IN Received data

18 RD(-) IN Received data

19 CS(+) IN When the host computer is set to stand by for data transmission, this

signal changes to “SPACE”.

(In this instance, the printer does not check the signal.)

23 CS(-) IN When the host computer is set to stand by for data transmission, this

signal changes to “SPACE”.

(In this instance, the printer does not check the signal.)

24 RS(+) OUT Data transmission request signal. When the printer is ready to

receive data, this signal changes to “SPASE”.

25 RS(-) OUT Data transmission request signal. When the printer is ready to

receive data, this signal changes to “SPASE”.

RS-422A (option)

Page 16: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 12 –

Board connector IL-W-24S-SD[JAE]

Applicable cableBD 300L (20mA current loop)

BD 300K (RS-422A)

3.3.8 CN9 (Optional Interface Board)

When using the optional 20mA current loop interface or the RS-422A interface, the optional interface board

must be mounted to the control board.

The following is the method of mounting the interface board to the control board.

1 Connect the optional interface board connector to connector CN9 on the control board.

2 At the same time, insert the plastic board support into thr hole on the interface board.

3 Switch SW5 and SW6 on the control board from A-C to B-C.

4 When using the optional 20mA current loop interface, the optional interface board mst be munted to the

DIP switch 3-5 on the control board.

When the DIP switch is ON...SW1 is B-C

Wheb the DIP switch is OFF...SW1 is A-C

Fig. 3-11 Installing the optional interface board

Fig. 3-12 Switch SW5 and SW6 (BD300L)

Optional board support

CN9

Control board

Optional interface board

SW6

SW5

Page 17: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 13 –

3.3.9 CN10 (Control Panel Signals)

Board connector B8B-PH-K J.S.T

Applicable cable set Cable Unit 8 × 510C BD300F (Optional)

Fig.3-13 Cable Unit 8 × 510C BD300F (Optional)

Pin No. Signal Name Function Pin No. Signal Name Function

1 +5V +5V 5 ON LINE LAMP On line lamp

2 ON LINE SWOn-line/Off-line 6 FEED SW Paper feed switch

selector switch 7 N.C. Not connected

3 POWER LAMP Power lamp 8 GND Ground

4 ALARM LAMP Alarm lamp

The control panel circuit is to be created by the user. Fig. 3-14 shows a sample diagram of the control panel

circuit.

In case a control panel circuit is installed, the functions described on the following page become available.

R1 to R3 270Ω resistor, l/4W

LED1,3 Diode LT1E21A (SHARP)

LED2 Diode LT1D1lA (SHARP)

SW l, 2 Pushbutton switch SKHHAL (ALPS)

Fig. 3-14 Sample Diagram of a Control Panel Circuit

(1) ON LINE switch

This pushbutton switch sets the printer to either on-line or off-line status. When on-line status is entered,

the ON LINE lamp lights.

1

8

Control board side Control panel side

500 - 0 mm+10

10-0 mm+2

1

3R1 LED1

+5V

GND

4R2 LED2

5R3 LED3

POWER LAMP

ALARM LAMP

ON LINE LAMP

2SW1

ON LINE SW

6SW2

8

FEED SW

7

Page 18: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 14 –

(2) FEED switch

When this pushbutton switch is pressed once briefly (for 0.5 seconds or less), the paper is fed forward

by one line. When it is held down continuously, the paper is fed forward continuously until the switch

is released.

This operation can be performed while the printer is in either on-line or off-line status.

(3) FEED switch + POWER ON (The FEED switch is held down while the printer is turned on)

A self-test pattern is printed to check the printer’s printing functions. The ROM Version No., DIP switch

settings, interface settings, and characters are printed in sequence.

If the FEED switch is pressed at the time self-test printing is completed, only the printing of the

characters can be repeated.

In the case of auto cutter equipped type printer mechanism (MP342F-24-A and MP341F-24-A), partial

cutting and full cutting will be repeatedly performed after completed character printing.

Fig. 3-15 Sample Printout of the Self-Test Pattern

(When using printer mechanism MP312F-24-A)

(4) ON LINE switch + POWER ON(The ON LINE switch is held down while the printer is turned on)

When this mode is activated, all of the data sent from a personal computer or other connected host will

be printed as hexadecimal codes.

By sending a program you have written to the printer, you can check whether or not the control codes

are being properly received by the printer.

Page 19: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 15 –

If the final line of data does not fill an entire line, the final line of data will not be printed. That line will

be printed, however, when the ON LINE switch is pressed and the printer enters off-line status. To cancel

this mode, turn off the printer.

Fig. 3-16 Sample Hexadecimal Dump Printout

(When using printer mechanism MP312F-24-A)

(5) FEED switch + ON LINE switch + POWER ON (Turn the power on while holding both the FEED and

ON LINE switches depressed.)

This operation clears the printer buffer. (The buzzer gives two short beeps.)

When DIP switch 1-7 of this board is set to ON (which is the factory presetting), the RAM back-up

function operates to maintain the data in the data buffer, even if the power for the board is shut off due

to power failure, etc.

However, when the board power is shut off for more than 10 hours, the data content will become unstable

and its content could degenerate and become unusable in the worst instances. For this reason, when the

board power is turned off for more than 10 hours, perform the above operation to clear the data in the data

buffer.

Note that the data in the buffer can also be cleared by control code < CAN >.

(6) ON LINE switch + FEED switch (In off-line status, the ON LINE switch is held down while the FEED

switch is pressed)

While these two switches are pressed, the paper is fed forward in units of n/72th inch each.

(7) Indicator Lamps

The seven states described in the following table are indicated by the status of the POWER, ALARM,

and ON LINE lamps.

Printer Status POWER Lamp ALARM Lamp ON LINE Lamp

1 Power is on ON OFF ON

2 On-line status ON OFF ON

3 Off-line status ON OFF OFF

4 Validation enabled ON OFF Flashing

5 Mechanical error ON Flashing OFF

6 CPU error ON ON ON

7 Power is off OFF OFF OFF

Page 20: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 16 –

a. Mechanical error

During operation of the printer mechanism, if either malfunction listed below is detected, a mechanical

error is regarded as having occurred, the printer mechanism stops operating, and the FAULT signal

assumes “mark” status. To cancel a mechanical error, turn the power off and then back on or press the

ON LINE switch, after the problem is corrected.

[Malfunctions of the printer mechanism]

• Lock-up of the carriage motor

• Malfunction of the timing detector (Timing signals are not generated)

• Signal timing error of the auto cutter

Even while in the status of no RAM back up with DIP SW1-7, the RAM is not cleared when power is

turned OFF. Printing resumes from the line being printed when the mechanism stopped.

b. CPU error

If operation of the CPU hangs up due to external noise or some other reason, the control board stops

operating. To cancel the CPU error state,the printer must be turned off then back on again.

3.3.10 CN11 (Power Supply)

Board connector 5483-04A [Molex]

Applicable cable set Cable U4 × 510C BD300F (Optional)

Fig. 3-17 Cable U4 × 510C BD300F (Optional)

PinNo. Simal Name Function

1 +25V +25V power supply

2 M-GND Ground

3 +5V +5V power supply

4 S-GND Signal ground

Supply voltage specifications

Voltage Average Current Peak Current

+25V + 5.0% 1.65A 3.5A

+5V + 2.5% 0.75A 1.2A

Note: Connect a minumum 3300 µF electrolytic capacitor to the 25 V outputs and a munimum 220 µF

electrolytic capacitor to the 5 V outputs as back-up capacitors.

1

4

Control board

500 - 0 mm+10

10-0 mm+2

Page 21: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 17 –

4. CONNECTION AND SETTINGS4.1 Connecting the Power Supply and Connectors

To connect a printer mechanism, power supply, and personal computer or other host computer to the control

board, use the optional cables to perform connection as shown in the figure below.

Fig. 4-1 Connecting the Power Supply and Connectors

6CN7

1

1

1

24

CN8

25

CN5

1 2

CN3

1 13

19 1CN2CN1

CN114

1

Cable Unit 8 × 510C BD300F

[Option]

Cable Unit 4 × 510C BD300F

(Option)

Cable Unit 14 × 265 SP312F (Option)

5

1CN6

Optional interface board CN9

Connect with Auto cutter equipped printer mechanism

1

8

CN10

14

Personal computer etc.

Peripheralunit

To Power Supply

Cable Unit 5 × 195 SP342F

Cable for Auto cutter equipped printer mechanism

Printer mechanism

Rewinder

(Option)

Cable Unit 19 × 265 SP312F (Option)

To control panel board

To paper out detector

8

1SW3

41

J3

J1 J2

SW4 8

1SW1

8

1SW2

SW6SW5

Page 22: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 18 –

4.3 Setting the Jumper

Set the jumpers J1 to J3 to the printer mechanism.

They are set OPEN in factory setting.

Printer mechanism J1 J2 J3

MP312F-24-AOPEN OPEN OPEN

MP312FV-24-A

MP311F-24-A SHORT OPEN OPEN

MP342F-24-A OPEN OPEN SHORT

MP341F-24-A SHORT OPEN SHORT

Please refer to fig. 3-2 for jumper locations.

Setting

OPEN

SHORT

4.2 Interface Connections

The following is a basic example of interface connections. (For interface connections, refer to the specifica-

tions for the respective interface.) IBM PC type serial port is shown as example.

Fig. 4-2 Example of interface connections for IBM PC (RS-232C)

Board Side

ShieldF-GND

TXD

RXD

RTS

CTS

1

2

3

4

5

S-GND

DTR

7

20

IBM PC Side

1 F-GND

2 TXD

3 RXD

4 RTS

5 CTS

6 DSR

7

20

S-GND

DTR

FAULT 14 8 DCD

DSR 6

Solder

Page 23: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 19 –

4.4 Setting the DIP Switches

U.S.A. France Germany U.K. Denmark Sweden Italy Spain

2-6 ON OFF ON OFF ON OFF ON OFF

2-7 ON ON OFF OFF ON ON OFF OFF

2-8 ON ON ON ON OFF OFF OFF OFF

Before changing the setting of any DIP switch, make sure to first turn off the power at both the controller board

and host computer.

When shipped from the factory, all DIP switch bits are set to ON.

4.4.1 DIP Switch 1Function ON OFF

1-1 (Not used) (Leave ON)

1-2 (Not used) (Leave ON)

1-3 Control code CR Disabled Enabled

1-4 When turning the DC1, DC3 mode Select Deselect

power on Addressable mode *1 Deselec Select

1-5 Setting the paper feed length l/6-inch l/8-inch

1-6 Setting the buffer size 4 K-bytes 256 bytes

1-7 RAM back up YES NO

1-8 Paper out detecion function Valid Invalid

*1 The addressable mode is valid only when optional RS-422A serial interface is mounted.

4.4.2 DIP Switch 2

Function ON OFF

2-1Character code table See the table below

2-2

2-3 (Not used) (Leave ON)

2-4 Paper widthMP312F(V), MP342F 3.25, 3.0 inches 2.25 inches

MP311F, MP341F 3.25, 3.0 inches

2-5 (Notused) (Leave ON)

2-6

2-7 International character set See the table below

2-8

U.S.A. & Europe IBM #1 IBM #2 Japan

2-1 ON OFF ON OFF

2-2 ON ON OFF OFF

International character set

Character code table

Page 24: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 20 –

4.4.3 DIP Switch 3

*1 This mode is only effective in case the paper cutter printer mechanism MP342F-24-A and MP341F-24-A has been mounted and the J3 jumper is in SHORT status (see section 4.3,“Setting the Jumper”).When auto cutter control mode is enabled, the auto cutter performs a full cut in case a paper feed instructionspecifying continuous feed for 7/6 inches or more is issued.

ON OFF

3-1

3-2 Data transfer rate See the table below

3-3

3-4J3 OPEN (Not used) (Not used)

J3 SHORT Auto cutter control mode disabled*1 Auto cutter control mode enabled*1

3-5 DTR mode X-ON/X-OFF mode

3-6 8-data bit 7-data bit

3-7 No parity check Parity check

3-8 Odd parity Even paeity

Baud rate 3-1 3-2 3-3

150 bps OFF OFF OFF

300 bps OFF OFF ON

600 bps OFF ON OFF

1200 bps OFF ON ON

2400 bps ON OFF OFF

4800 bps ON OFF OFF

9600 bps ON ON ON/OFF

4.4.4 DIP Switch 4

Function DC1,CD3 Addressable mode *2 DC1,DC3

Switch invalid mode #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 valid mode

4-1 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF

4-2 ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF

4-3 ON ON ON ON OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF

4-4 ON ON ON ON ON ON ON ON OFF OFF OFF OFF OFF OFF OFF OFF

*2: The addressable mode is valid only when an optional RS-422A serial interface is mounted.

For more details, see the description of the DC1 and DC3 codes in Chapter 6,“CONTROL CODES.”

Page 25: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 21 –

1. Data transmission method: Asynchronous serial interface

2. Baud rate: Selectable from 150, 300, 600, 1200, 2400, 4800,

9600 bps (Refer to “4.4 DIP Switch Setting”.)

3. Word length Start bit: 1 bitData bit: 7 or 8 bits (selectable. Refer to “4.4 DIPSwitch Setting”.)Parity bit: Odd, even or none (selectable. Refer to“4.4 DIP switch setting”.)Stop bit: 1 or 2 bit length

4. Signal polarity RS-232C (Standard feature)MARK: Logic“1” (-3V to -15V)SPACE: Logic “0” (+3V to +15V)

Current loop (oprional)MARK: Logic “1” (current ON)SPACE: Logic“0” (current OFF)

RS-422A (optional)MARK: Logic“1”

A is -0.2V or less than BSPACE: Logic “0”

A is 0.2V or more than B

5. INTERFACE5.1 Interface Specifications

5.2 Interface Circuit

5.2.1 RS-232C

Fig. 5-2 RS-232C Interface Circuit

Printer

Input (RXD, CTS)

75189 or equivalent

Host computer

Printer

75188 or equivalent

Host computer

Output (DTR, FAULT, TXD, RCH, RTS)

Fig. 5-1 Data Format

MARK "1"SPACE "0"

A B

b0 b1 b2 b3 b4 b5 b6 (b7)

C D

ABCD

: Start bit: Data bit: Parity bit: Stop bit

Page 26: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 22 –

5.2.2 Current Loop (Option)

Note: Adjust “R” so that the loop current is set within 10 to 20mA

Fig. 5-3 Current Loo Intergace Circuit

5.2.3 RS-422A Serial Interface (Option)

Fig. 5-4 RS-422A INterface Circuit

Printer R

+VHost computer

Input (TTY-RXD, TTY-RXDR)

Printer R

+VHost computer

Output (TTY-TXD, TTY-TXDR)

Printer( )

( )

Host computer

Printer Host computer

Input (RD, RS)

Output (SD, CS)

( )

( )

Page 27: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 23 –

Select international character set

< ESC > “R” n

(lB)H (52)H n

(00)H n (08)H

Selects the international character set corresponding to the value set for n.

n = (00)H:U.S.A. (03)H: England (06)H: Italy

(01)H: France (04)H: Denmark (07)H: Spain

(02)H: Germany (05)H: Sweden (08)H: Japan

The default international characters can also be set with DIP switches, however,

setting by control code takes priority over setting by DIP switches.

Refer to 9.2.5 ”Code Table” in Chapter 9.

Select IBM character set #2.

< ESC > “6”

(lB)H (36)H

Selects IBM character set #2.

This code is only valid when the character code table set by DIP switches 2-1 and

2-2 is IBM character set #1 or #2.

Select IBM character set #1.

< ESC > “7”

(lB)H (37)H

Selects IBM character set #1.

This code is only valid when the character code table set by DIP switches 2-1 and

2-2 is IBM character set #1 o r #2.

6. CONTROL CODES6.1 Control Codes Used in Character Setting

DEFINITION RANGE

FUNCTION

CODE

DEFINITION RANGE

OUTLINE

FUNCTION

CODE

OUTLINE

Note

FUNCTION

CODE

OUTLINE

Note

Page 28: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 24 –

Printer mechanism DIP Switch 2-4 ON OFF

MP312F-24-A Maximum no. of print columns 40 28MP312FV-24-A

MP342F-24-A CPI(Characters Per Inch) 15.4

MP311F-24-A Maximum no. of print columns 28 28

MP341F-24-A CPI (Characters Per Inch) 12.2

Select font matrix 7 × 9 (half-dots)

< ESC > “M”

(1B)H (4D)H

Selects font matrix 7 × 9 (half-dots).

The maximum number of print columns varies to the printer mechanism and the

DIP swith 2-4 (paper width) setting as follows:

This code valid only when received at the beginning of a line.

When the power is turned on, this code is automatically selected.

Select font matrix 5 × 9 (2 pulses-1 dot)

< ESC > “P”

(1B)H (50)H

Selects 5 × 9 font matrix. where 1 dot corresponds to 2 pulses of timing signal 1.

The maximum number of print columns varies to the printer mechanism and the

DIP switch 2-4 (paper width) setting as follows:

Printer mechanism DIP Switch 2-4 ON OFF

MP312F-24-A Maximum no. of print columns 33 23MP312FV-24-A

MP342F-24-A CPI (Character sPer Inch) 12.8

MP311F-24-A Maximum no. of print columns 23 23

MP341F-24-A CPI (Characters Per Inch) 10.2

This code valid only when received at the beginning of a line.

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

Page 29: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 25 –

Select font matrix 5 × 9 (3pulses-1 dot)

< ESC > “ : ”

(lB)H (3A)H

Selects 5 × 9 font matrix, where 1 dot corresponds to 3 pulses of timing signal 1.

The maximum number of print columns varies to the printer mechanism and the DIP

switch 2-4 (paper width) setting as follows :

Printer mechanism DIP Switch 2-4 ON OFF

MP312F-24-A Maximum no. of print columns 22 15MP312FV-24-AMP342F-24-A CPI (Characters Per Inch) 8.5

This code valid only when received at the baginning of a line.

This code will be ignored if the printer mechanism MP311F-24-A or MP341F-24-

A is used.

Select expanded character mode

< SO >

(0E)H

Data following this code is printed in double-width characters.

Same as < ESC >“W” “l” or < ESC > “W” < 1 >.

Cancel expanded character mode.

< DC4 >

(14)H

Cancels expanded character mode set by < SO > or < ESC > “W” “l” or < ESC >“W”

< 1 > code (Data following this code is printed out in normal size characters.)

Same as < ESC >“W” “0” or < ESC >“W” < 0 >.

Select expanded character mode.

< ESC >“W” “1” or < ESC >“W” < 1 >.

(lB)H (57)H (31)H or (lB)H (57)H (01)H

Data following this code is printed in double-width characters.

Same as < SO >.

Cancel expanded character mode.

< ESC >“W” “0” or < ESC >“W” < 0 >.

(lB)H (57)H (30)H or (lB)H (57)H (00)H

Cancels expanded character mode set by < ESC >“W” “l” or < ESC >“W” < 1 > or

< SO > code (Data following this code is printed out in normal size characters.)

Same as < DC4 >

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

Page 30: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 26 –

Select emphasized print mode.

< ESC >“E”

(lB)H (45)H

Data following this code is printed in the emphasized print mode. In this mode only

uni-directional printing is performed.

Cancel emphasized print mode.

< ESC > “F”

(lB)H (46)H

Cancels emphasized print mode.

Select underline mode

< ESC > “-” “1” or < ESC > “-”< 1 >

(lB)H (2D)H (31)H or (lB)H (2D)H (01)H

Data following this code is printed out underlined. (However, the spaces generated

by horizontal tab are not underlined.)

Cancel underline mode

< ESC > “-” “0” or < ESC > “-” < 0 >

(lB)H (2D)H (30)H or (lB)H (2D)H (00)H

Cancels underline mode.

Select overline mode

< ESC > “_” “1” or < ESC > “_” < 1 >

(lB)H (5F)H (31)H or (lB)H (5F)H (01)H

Data following this code is printed out with an overline. (However the spaces

generated by horizontal tab are not overlined.)

Cancel overline mode

< ESC > “_” “0” or < ESC > “_” < 0 >

(lB)H (5F)H (30)H or (lB)H (5F)H (00)H

Cancels overline mode.

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

Page 31: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 27 –

Select highlighted print mode.

<ESC> “4”

(lB)H (34)H

Prints with highlighted characters.

If an underline, overline or inverted print command is input while the highlighted

print mode is in effect, the highlighted mode will be canceled and the newly input

command will be executed. If a highlighted print command is received while the

underline, overline or inverted print mode is in effect, the previously set mode

is canceled and the highlighted print mode will be set.

Cancels highlighted print mode.

< ESC >“5”

(lB)H (35)H

Cancels highlighted print mode.

Select inverted print mode

< SI >

(0F)H

Data following this code is printed out in inverted characters. This code is valid

only when input at the beginning of a line, thus, normal and inverted characters

cannot be mixed in on the same line.

Cancels inverted print mode

< DC2 >

(12)H

Cancels the inverted character mode. This code is valid only when input at the

beginning of a line.

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

Page 32: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 28 –

6.2 Control Codes Used for Line Spacing

Line feed

< LF >

(0A)H

Data in the line buffer is printed out and one line is fed. If data does not exist before

this code is received, the printer only feeds one line.

Line feed (Same as LF)

< CR >

(0D)H

Functions the same as an LF code.

When DIP SW 1-3 is set to ON, this code becomes invalid.

Set l/6-inch line feed

< ESC > “z” “1” or < ESC > “z” < 1 >

(lB)H (7A)H (31)H or (lB)Hn (7A)H (01)H

Line feed is set at n/216-inch after this code is received.

Set 1/8 inch line feed.

< ESC > “0”

(lB)H (30)H

Line feed is set at 1/8 inch after this code is received.

Feed paper n lines

< ESC > “a” n

(lB)H (61)H n

1 n 127

After data in the line buffer is printed out feeds the paper n lines.

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

DEFINITION RANGE

Page 33: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 29 –

6.3 Control Codes Used for Page Layout

Page feed (form feed)

< FF >

(0C)H

After data in the line buffer is printed out, feeds the paper to the top of the next

page.

Set page length at n lines

< ESC > “C” n

(lB)H (43)H n

1 n 255 (default value n = 42)

Sets page length at n lines.

Set page length at n inches

< ESC > “C” < 0 > n

(lB)H (43)H (00)H n

1 n 127

Sets page length at n inches.

Execute vertical tab.

< VT >

(0B)H

Feeds the paper to the next vertical tab set position.

When a vertical tab is not set, line feed is not performed. If the current line is at or

below the last vertical tab set position, the paper feeds to the top of the next page.

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

DEFINITION RANGE

FUNCTION

CODE

OUTLINE

DEFINITION RANGE

Page 34: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 30 –

Set vertical tab position

< ESC > “B” n1 n2...nk < 0 >

(lB)H (42)H n1 n2...nk (00)H

1 n1 < n2 < n3 <...< nk 255, 1 k 16

Cancels all current vertical tab positions and sets new vertical tab positions at lines

n1, n2, etc.,where n1, n2, etc. are numbers between 1 and 255. A maximum of 16

vertical tab positions can be set. The tab positions must be specified in ascending

order; any violation of ascending order terminates the tab position list. Standard

termination is by the < 0 > control code. The vertical tab positions are set in terms

of the current line spacing and do not move if the line spacing is changed later.

If a tab set position < nk > is equivalent or smaller than < nk-1 > just preceding

the tab set position, setting of vertical tab is assumed as complete.

Set bottom margin

< ESC > “N” n

(lB)H (4E)H n

0 n 255 (Default n = 0)

Sets bottom margin to n lines.

Cancel bottom margin

< ESC > “O”

(lB)H (4F)H

Cancels bottom margin.

Set left margin.

< ESC > “l” n

(lB)H (6C)H n

0 n (right margin -2)

Sets the left margin at column n in the current character pitch. The left margin does

not move if the character pitch is changed later. The left margin must be at least two

columns to the left of the right margin and within the limits above.

FUNCTION

CODE

OUTLINE

DEFINITION RANGE

FUNCTION

CODE

OUTLINE

DEFINITION RANGE

Note

FUNCTION

CODE

OUTLINE

DEFINITION RANGE

FUNCTION

CODE

OUTLINE

Page 35: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 31 –

Set right margin

< ESC > “Q” n

(lB)H (51)H n

2 n (maximum no. of print columns)

Sets the right margin at column n in the current character pitch. Column n becomes

the last character position the line. The right margin does not move if the character

pitch is changed later. the right margin must be within the limits above.

Execute horizontal tab.

<HT>

(09)H

The print position skips to the next horizontal tab position in line. When no

horizontal tab position is set, this code is ignored. (Underlining and overline do not

take place in the spaces between characters set with the horizontal tab function.)

Set horizontal tab position

< ESC > “D” n1 n2....nk < 0 >

(1B)H (44)H n1 n2....nk (00)H

1 n1 < n2 < n3... < nk (maximum no. of print columns), 1 k 16

Cancels all current horizontal tab positions and sets new tab positions at columns n1,

n2, etc. in the current character pitch. The maximum number of horizontal tab

positions allowed is 16. The tab positions must be specified in ascending order; any

violation of ascending order terminates the tab position list. Standard termination is

by the < 0 > control code. To clear all tab positions, specify < ESC > “D” < 0 >.

When the horizontal tab set position < nk > is equivalent or smaller than < nk-1 >

which is the column just preceding the set tab position, vertical tab setting is

assumed as complete.

Note

FUNCTION

CODE

OUTLINE

DEFINITION RANGE

FUNCTION

CODE

OUTLINE

DEFINITION RANGE

FUNCTION

CODE

OUTLINE

Page 36: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 32 –

6.4 Control Codes Used for Graphics Printing

Set 7/72 inch line feed

< ESC > “l”(lB)H (31)H

Line feed is set at 7/72 inch after this code is received.

Define n/72 inch line feed

< ESC > “A” n(lB)H (41)H n

0 n 85 (Default n = 12)

Line feed is defined at n/72 inch after this code is received.This code sets the feed at n/72 inch with the < ESC > “2”code.

Set n/72 inch line feed

<ESC> “2”(lB)H (32)H

Sets the line feed at a defined value with the < ESC > “A” previouslydescribed.

One time line feed of n/72 inch.

< ESC > “J” n(lB)H (4A)H n

1 n 255

Activates the n/72-inch paper feed once.

Set 1/12 inch line feed

< ESC > “z” “0” or < ESC > “z” < 0 >(lB)H (7A)H (30)H or (lB)H (7A)H (00)H

Line feed is set at 1/12 inch after this code is received.

Set n/144 inch line feed.

< ESC > “y” n(lB)H (79)H n

1 n 255

Line feed is set at l/144-inch after this code is received.

Set n/216-inch line feed.

< ESC > “3” n(lB)H (33)H n

1 n 255

Line feed is set at n/216-inch after this code is received.The actual line feed is set at INT (n × 2/3 + 0.5)/144inch.

OUTLINE

FUNCTION

CODE

FUNCTION

CODE

DEFINITION RANGE

OUTLINE

OUTLINE

FUNCTION

CODE

FUNCTION

CODE

DEFINITION RANGE

OUTLINE

FUNCTION

CODE

DEFINITION RANGE

OUTLINE

FUNCTION

CODE

DEFINITION RANGE

OUTLINE

OUTLINE

FUNCTION

CODE

Page 37: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 33 –

8 dot single density bit image

< ESC > “K” n1 < 0 > m1 rn2....

(lB)H (4B)H n1 (00)H m1 m2....

1 n1 k

Excutes 8 dot bit image print determined by “n1”. The total number of bit image

data bytes in one line is equal to n1.

The value of k varies to the printer mechanism

Printer mechanism k

MP312F-24-A, MP312FV-24-A, MP342F-24-A 200

MP311F-24-A, MP341F-24-A 140

The printer ignores any data bytes over the specified amount allowed in one

line. When the bit image print is finished the printer automatically returns to

the character mode.

Actually, let us consider printing as a means of bit image. We will create the

design below using bit image.

First, since the volume of data is 30, n1 = (lE)H. If the data m1~ m30 is converted

to hexadecimal, it appears as shown below.

m1 00000001 01

m2 00011110 1E

m3 00111110 3Em4 01011111 5F

m5 00011111 1F

m6 01011110 5Em7 00011110 1E

m8 00111111 3F

m9 00101111 2Fm10 00111110 3E

Data Binary Hexa- Data Binary Hexa- Data Binary Hexa-decimal decimal decimal

m11 00111110 3E

m12 00000010 02

m13 00000010 02m14 00111110 3E

m15 00111110 3E

m16 00101111 2Fm17 00101111 2F

m18 00111110 3E

m19 00101110 2Em20 00101110 2E

m21 00111110 3E

m22 00101110 2E

m23 00101110 2Em24 00111110 3E

m25 00101111 2F

m26 00101111 2Fm27 00111110 3E

m28 00111110 3E

m29 00000010 02m30 00000010 02

Printing Samples

EXAMPLE

FUNCTION

CODE

DEFINITION RANGE

OUTLINE

Page 38: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 34 –

8 dot double density bit image

< ESC > “L” n1 n2 m1 m2....

(lB)H (4C)H n1 n2 m1 m2....

1 n1 + 256 × n2 k

Executes double density bit image printing (half-dot printing) determined by

“n1” and “n2”. The total number of bit image data bytes in one line is equal to

n1 + n2 × 256.

The value of k varies to the printer mechanism

Printer mechanism k

MP312F-24-A, MP312FV-24-A,MP342F-24-A 400

MP311F-24-A, MP341F-24-A 280

Refer to < ESC > K as to the relation between the dot position and the bit

number. The printer ignores any data bytes over the specified amount al-

lowed in one line.

The printer does not print adjacent dots. When the bit image printing is

finished, the printer automatically returns to the character mode.

For double density bit image printing, dots cannot be printed overlapping

each other in the horizontal direction.

The following is an example of this.

FUNCTION

CODE

DEFINITION RANGE

OUTLINE

CODE

Page 39: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 35 –

Select vertical expanded character mode

<ESC> “h” “1” or < ESC > “h” < 1 >

(lB)H (68)H (31)H or(lB)H (68)H (01)H

Prints characters two times the normal vertical size after the code is received.

However, the bit image mode < ESC > “K” and < ESC > “L” are excluded.

(1) When combined with the < SO > code, this code enables printing of the

characters in two times the normal vertical and horizontal size.

(2) This code is not combined with the inverted print mode < SI > code.

(3) For the 6 × 12 dots IBM block graphic (the character code table (B0)H-(DF)H

and (F4)H-(F5)H of IBM character set #1 and #2) of the font construction,

enlargement is only vertical in the upper 8 dots.

(4) The relationship of the vertically enlarged character and the normal

character is matched at the lower level.

Cancel vertical expanded character mode

< ESC > “h” “0” or < ESC > “h” < 0 >

(lB)H (68)H (30)H or (lB)H (68)H (00)H

Cancels vertical expanded character mode

OUTLINE

FUNCTION

CODE

Note

OUTLINE

FUNCTION

CODE

Page 40: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 36 –

6.5 Control Codes Used for Download Characters

Definition of download characters

When 7 × 9 (half-dots) font matrix is set (default setting):

< ESC > “&” < 0 > n1 n2 [m0 m1 m2 m3 m4 m5 m6 m7] n2 - n1 + 1

(lB)H (26)H (00)H n1 n2 [m0 m1 m2 m3 m4 m5 m6 m7] n2 - n1 + 1

When the 5 × 9 font matrix is set:

< ESC > “&” < 0 > n1 n2 [m0 m1 m2 m3 m4 m5] n2 - n1 +1

(lB)H (26)H (00)H n1 n2 [m0 m1 m2 m3 m4 m5] n2 - n1 +1

(2l)H n1 n2 (7F)H, m0 = (00)H or m0 = (80)H

Defines download characters

Up to 10 download characters can be defined and the defined character patterns

can be stored in the printer’s RAM.

Defining of download characters begins with character code nl and completes

with n2. When only one character is defined, n1 = n2.

m0 indicates the relationship between the character pattern and print head.

m1 m2.... Indicate the character pattern

When the 7 × 9 (half-dots) font matrix is set (the default setting), printing of

adjacent horizontal dots is not allowed.

FUNCTION

CODE

DEFINITION RANGE

OUTLINE

Note

Page 41: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 37 –

Enable download character set

< ESC > “%” “l” or < ESC > “%” < 1 >

(lB)H (25)H (31)H or (lB)H (25)H (01)H

Enables the download character set

Download characters defined by the ESC & 0 code cannot be printed until enabled

by this command.

Disable download character set.

< ESC > “%” “ 0” or < ESC > “%” < 0 >

(lB)H (25)H (30)H or (lB)H (25)H (00)H

Disables the selected download character set and selects the built-in character set.

When the power for the printer is initially turned on, the built-in character set is

selected.

To print a download character when the 7 × 9 (half-dots) font matrix is set.

(1) Design the download character to be used at code positions (21)H, (22)H, and

(23)H.

(2) Define the download characters.

When character codes where the download character is written are specified as

(2l)H, (22)H, (23)H, n1 = (2l)H, n2 = (23)H are obtained.

If the relationship between the character pattern data and printing head is specified

to “not use pin 9”, m0 = (80)H is obtained. When data m1 to m7 are converted into

hexadecimal data, they are indicated as follows.

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

EXAMPLE

Page 42: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 38 –

Data Binary Hexa-Data Binary

Hexa-Data Binary

Hexa-decimal decimal decimal

m1 10100000 A0

m2 00000000 00

m3 10100000 A0

m4 00011111 1F

m5 10100000 A0

m6 00000000 00

m7 10100000 A0

m1 00111000 3C

m2 01000010 42

m3 10100101 A5

m4 00000000 00

m5 10100101 A5

m6 01000010 42

m7 00111000 3C

m1 10011000 98

m2 01100100 64

m3 10000010 82

m4 00000001 01

m5 10000010 82

m6 01100100 64

m7 10011000 98

Printing Samples

Example of transmitting data

(1) Definition of download (lB)H (26)H (00)H (21)H (23)H (80)H (A0)H (00)H

characters (A0)H (lF)H (A0)H (00)H (A0)H (80)H (98)H (64)H

(82)H (01)H (82)H (64)H (98)H (80)H (3C)H (42)H

(A5)H (00)H (A5)H (42)H (3C)H

(2) Selecting the download (lB)H (25)H (31)H

character set

(3) Character codes (21)H (22)H (23)H (OA)H

(4) Canceling the download (lB)H (25)H (30)H

character set

(5) Character codes (21)H (22)H (23)H (0A)H

Page 43: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 39 –

6.6 Control Codes Used for Peripheral Units

Adjust drive pulse width for peripheral unit 1

< ESC > < BEL > n1 n2

(lB)H (07)H n1 n2

1 n1 127, 1 n2 127 (default setting n1 = n2 = 20)

Adjusts drive pulse width for peripheral devices requiring other than standard

200 ms pulse time and delay time

Energizing time = 10 × n1 (ins)

Delay time = 10 × n2 (ins)

Executed by < BEL >, < FS > codes.

Adjustment is not necessary for standard cash drawers in the U.S.A. market.

Deferred drive command for peripheral unit 1

< BEL >

(07)H

Executes drive pulse for peripheral unit 1 (deferred).

Immediate drive command for peripheral unit 1

< FS >

(lC)H

Executes drive pulse for peripheral unit 1 (immediate).

This code differs from the < BEL > code as follows:

When the printer receives an < FS > code, the command is executed immediately.

The < BEL > code is stored in the data buffer in the same manner as other codes, and

executed in the order in which they are received.

FUNCTION

CODE

DEFINITION RANGE

OUTLINE

Note

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

Page 44: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 40 –

6.7 Other Control Codes

Immediate drive command for peripheral unit 2

< SUB >

(lA)H

Drives peripheral unit 2. Pulse width is fixed at 200 ms with a fixed delay time

of 200 ms.

When the printer receives a < SUB > code, the command is executed immediately.

Same as < EM >.

Peripheral units 1 and 2 cannot be driven simultaneously.

Immediate drive command for peripheral unit 2

< EM >

(19)H

Drives peripheral unit 2. Pulse width is fixed at 200 ms with a fixed delay time

of 200 ms.

When the printer receives a < EM > code, the command is executed immediately.

Same as < SUB >.

Peripheral units 1 and 2 cannot be driven simultaneously.

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

Note

Note

Sound buzzer

< RS >

(lE)H

Generates a short alarm.

Cancel print data in buffer.

< CAN >

(18)H

Clears data buffer and line buffer

Clears the data in the data buffer in the STX-ETX mode.

Set deselect mode

< DC3 >

(13)H

This function differs depending on the setting of DIP switch 4.

a) When the DC1, DC3 invalid mode is set (DIP switches 4-1 to 4-4 are all set

to ON), the control board ignores this code.

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

Page 45: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 41 –

b) In the DC1, DC3 valid mode (with DIP switches 4-1 to 4-4 set to OFF), data

following this code is ignored when the printer receives a < DC3 > code.

The deselect mode is canceled by < DC1 > code.

c) If the printer receives a < DC3 > code during an addressable mode (with DIP

swiitches 4-1 to 4-4 set to settings other than a) and b) above,), the data

following this code is ignored.

Deselect mode can be canceled by a < DC1 > n code.

Note that addressable mode is valid only when the RS-422A interface option

is installed.

Set select mode

< DC1 > or < DC > n

(11)H or (11)H n

This function differs depending on the setting of DIP switch 4.

a) When the DC1, DC3 invalid mode is set (DIP switches 4-1 to 4-4 are all set to

ON), the control board ignores this code.

b) In the DC1, DC3 valid mode (with DIP switches 4-1 to 4-4 set to OFF), when

the control board receives a < DC1 > code, the deselect mode is canceled and

data following this code is input to the buffer.

c) If the printer receives a < DC1 > n code (n is the DIP switch controlled address)

during the addressable mode (with DIP switches 4-1 to 4-4 set other than

settings a) and b) above,), the deselect mode is canceled and data folloing this

code is input to the buffer.

Note that addressable mode is valid only when optional RS-422A interface is

instslled.

Select uni-directional print mode.

< ESC > “U” “l” or < ESC > “U” < 1 >

(lB)H (55)H (31)H or (lB)H (55)H (01)H

Prints only when the print head moves from left to right.

Select bi-directional print mode

< ESC > “U” “O” or < ESC > “U”< 0 >

(lB)H (55)H (30)H or (lB)H (55)H (00)H

Returns to the standard bi-directional print mode. (This mode is set automatically

when the printer power is turned on.)

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

Page 46: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 42 –

Initialize printer

< ESC > “@”

(lB)H (40)H

Cancels the various conditions set after the power was turned on and resets the

printer to the intial settings in effect when the power is turned on.

In this instance, contents of the line buffer and the data buffer are not cleared.

Enquiry

< ENQ >

(05)H

Causes control board to transmit status byte (not in STX-ETX mode).

When this code is received after receiving text data in the STX-ETX mode, the

control board transmits the status and check byte.

When IBM character set #2 is selected by character code, codes < ENQ > does not

exist. (In this instance, select another code.)

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

Note

OUTLINE

FUNCTION

CODE

OUTLINE

FUNCTION

CODE

Note

U.S.A & Europe I BM #1 IBM #2 Japan

(05)H < ENQ > < ENQ > ♣ < ENQ >

Enter STX-ETX mode

< STX >

(02)H

Sets the STX-ETX mode.

Terminate STX-ETX mode.

< ETX>

(03)H

Terminates the STX-ETX mode and prints out the text data.

When IBM character set #2 is selected by character code, codes < ETX > does not

exist. (In this instance, select another code.)

U.S.A & Europe I BM #1 IBM #2 Japan

(03)H < ETX > < ETX > ♥ < ETX >

Page 47: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 43 –

OUTLINE

FUNCTION

CODE

(1) Character data and immediate execution command < CAN > are valid for data.

(2) Printing modes (such as emphasized, inverted, expanded character modes,

etc.) which were set before validation printing are invalid during validation

printing. (These modes become valid again after validation printing is

completed.)

(3) This code is valid only when attaching mechanism MP312FV-24-A with

validation function.

Trigger auto-cutter drive (full cut)

< ESC > “d” “0” or < ESC > “d” < 0 >

(lB)H (64)H (30)H or (1B)H (64)H (00)H

Causes the printer mechanism to trigger auto-cutter (full cut).

This code is valid only when attaching mechanism with paper-cutter.

Trigger auto-cutter drive (partial cut)

< ESC > “d” “1” or < ESC > “d” < 1 >

(lB)H (64)H (31)H or (lB)H (64)H (01)H

Causes the printer mechanism to trigger auto-cutter (partial cut).

This code is valid only when attaching mechanism with paper-cutter.

OUTLINE

FUNCTION

CODE

Note

Note

Note

Select validation printing

< GS > data < LF >

(1D)H data (0A)

Prints up to 32 columns of the 15.4-CPI size characters on one line.OUTLINE

FUNCTION

CODE

Page 48: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 44 –

7. DATA STRUCTURE7.1 DTR Mode

This mode is accessed when the DIP switch 3-5 is ON.

Signals are controlled using the DTR line as BUSY flag.

If a control board errors do not occur after the power is turned on, the DTR signal line changes to “SPACE”.

When the host computer confirms that the DTR signal line is set to “SPASE”, the host computer sends the data

text via the RXD signal line to the control board. Also, the control board will set the DTR signal line to

“MARK”, transmission of the data text is stopped. In this instance, data can still be received up until the data

buffer becomes completely full.

When the empty space in the data buffer is increased following printing (when the data in the data buffer is

reduced to 256 bytes or less), the control board sets the DTR signal line to “SPACE”.

Data buffer

Full Near Full

Remainder256 bytes

DTR "MARK"

Near Empty Empty

256 bytes

DTR "SPACE"

When paper is out

RXD

DTR

OFF LINE ON LINE

When printing

PAPER OUTsignal

Power on

Paper end Press the ON LINE switchafter loading paper.

RXD

DTR

Printing

Data Data Data

Buffer full Buffer empty

Power on

Page 49: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 45 –

[Framing error]

A framing error occurs when SPACE is detected at the stop bit. When a framing error or a vertical parity error

occurs for the data which is received, the printer prints out a “?” mark to indicate that the error occurred.

[Mechanical error]

Immediately after a mechanical error occurs, the control board sets the DTR to “MARK” and then sets the

control board to OFF LINE.

[Paper out]

When the “paper out” detector senses the end of the paper, the printer stops printing after printing a maximum

of two more lines or on feeding the paper. Immediately after a “paper out” condition is detected, the printer

sets to OFF LINE and the DTR changes to “MARK”. (To reset printer after a “paper out”, load paper into the

printer and press the ON LINE switch to set the printer to ON LINE.)

[Compulsion signal]

When pin 6 of the peripheral unit drive circuit connector is set “HIGH”, status bit 7 becomes “1.”

[Status]

b7 b6 b5 b4 b3 b2 b1 b0

0

( Constantly set at “0” )

Vertical parity error1: errorFraming error1: errorMechanical error1: errorPaper empty1: emptyBuffer empty1: emptyBuffer overflow1: overflowCompulsion signalHigh level(Switch is set to ON)

Page 50: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 46 –

7.2 X-ON/X-OFF Mode

This mode accessed when the DIP switch 3-5 is OFF.

If control board errors do not occur after the power is turned on, the printer outputs an X-ON (DC1 by control

code; 11H by hexadecimal data) signal on the TXD signal line which sends it to the host computer. When the

host computer receives the X-ON signal, the host computer transmits the data to the RXD signal line for the

printer. If data text is not sent from the host computer (even after transmitting the X-ON signal to the host

computer), the printer outputs an X-ON signal at 3 second intervals until the printer receives data.

The printer starts outputting an X-OFF (DC3, 13H) signal when the empty space in the buffer reduces below

256 bytes. When the host computer receives the X-OFF signal, it halts output of data. (however, the control

board can continue receiving data until the buffer becomes completely full.)

Output of the X-ON signal is resumed when the data in the buffer is printed out and drops to below 256 bytes.

TXD

X-ON X-OFFX-OFF

X-OFFX-ON X-OFF

RXD Data

X-OFF

Data

Printing

Paper out signal

ON LINE lamp

ON

OFF

Power on Paper out

X-OFF X-ON

Load paper and pressthe ON LINE switch.

Data

Data buffer

Full Near Full

Remainder256 bytes

X-OFF

Near Empty Empty

256 bytes

X-ON

Page 51: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 47 –

[Framing error]

A framing error occurs when SPACE is detected at the stop bit. When a framing error or a vertical parity error

occurs for the data which is received, the printer prints out a “?” mark to indicate that the error occurred.

[Mechanical error]

Mechanical errors are detected when the carriage motor locks and printing stops. After the error occurs, the

control board outputs an X-OFF signal and stops printing. The control board sets the DTR signal to “MARK”

and sets to OFF LINE within five seconds after a mechanical error occurs.

[Paper out]

When the “paper out” detector senses the end of the paper, the printer stops printing after printing a maximum

of two more lines or on feeding the paper. The printer will set the DTR to “MARK” and set the printer to OFF

LINE five seconds after a “paper out”, load a new roll of paper into the printer and press the OFF LINE switch

to set the printer ON LINE.

[Compulsion signal]

When pin 6 of the peripheral unit drive circuit connector is set at “HIGH”, status bit 7 becomes “1.”

[Status]

b7 b6 b5 b4 b3 b2 b1 b0

0

( Constantly set at “0” )

Vertical parity error1: errorFraming error1: errorMechanical error1: errorPaper empty1: emptyBuffer empty1: emptyBuffer overflow1: overflowCompulsion signalHigh level(Switch is set to ON)

Page 52: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 48 –

7.3 STX/ETX Mode

This mode is accessed from whichever DTR mode or X-ON/X-OFF mode.

To set this mode, the data buffer must be empty.

The host computer sends an ENQ code to the control board and acknowledges the printer starus. Then,the host

computer checks if the printer buffer is empty. After the host computer detects that the buffer is empty, a STX

code and data are transmitted. After 1 block of data is transmitted, the host computer sends an ENQ code to

the printer and then receives the printer status and check byte (horizontal parity for the control board).

At this point, the host computer performs a status and horizontal parity check. When the host computer

determines that there was no error, it transmits an ETX code which serves as text end code. After the control

board receives the ETX code, data in the data buffer is printed out. If an error occurs, a CAN code is transmitted

by the host computer. (In this instance, the data which was previously sent to the buffer is cleared, thus, the

host computer must retransmit the same data to the control board.)

A flowchart of this operation is illustrated on the following page.

[Status]

b7 b6 b5 b4 b3 b2 b1 b0

0

( Constantly set at “0” )

Vertical parity error1: errorFraming error1: errorMechanical error1: errorPaper empty1: emptyBuffer empty1: emptyBuffer overflow1: overflowCompulsion signalHigh level(Switch is set to ON)

Page 53: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 49 –

STX/ETX Mode flow diagram for host computer

Starts theSTX-ETX mode.

Sends ENQ

Receives statusbyte.

NO Is thedata buffer

empty ?

YES

Sends STX signal

Is an oddparity check ?

NO

YES

(FF)H is set forthe test byte.

The test byte is set at (O)H.

Sends an ENQsignal.

Receives statussignal

Receivesa check byte.

YES

NO

Is the status an

error ?

Horizontalparity check

Check byte =test byte ?

NO

YES

Sends ETX

(Priniting)

Acquires the exclusive ORof the content of the testbyte and the data to sent,then it is used as the contentof the test byte.

Transmits the datato the printer.

NO

YES

Is this thelast data

in a block ?

Sends CAN

Ends theSTX-ETX mode

NO

YES

Is there a datablock in the

STX-ETX mode ?

RET

Check byte:Horizontal parity of the control board.Test byte:Horizontal parity of the host computer.

Page 54: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 50 –

8. PCBOARD, CIRCUITDIAGRAM, PARTS LIST8.1 PC Board Dimension Drawing

CN7CN8

CN10

CN5 CN3

CN2

CN1

CN11

CN6

35 29

17

3- 3.7 0+0.1

3.8

10 SOLDER SIDE (F-GND, S-GND)

4.7

3.7

5

7

144 0.3156

705 570

140 0.3

150

2

R2

166

2

Unit : mm

Max. 20

Max. 4

1.6

+-

+-

Page 55: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 51 –

8.2 Component Layout

Page 56: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 52 –

8.3 Circuit Diagram

CN8

CN9

LT1081

IC7

IC9

9

10

17

18

19

23

24

25

4RTS

15

2

20

3

5

16

11

(MULTI-PRINTER TXD)

TXD

DTR

RXD

CTS

(MULTI-PRINTER DTR)

RCH

14FAULT

7GND

13GND

1F-GND

22

8

5 +24V

+5V

23

19

20

21

9

10

1116

6SW5 SLIDE

BC

A

65

63

10

11

12

9

B

A15 +5V

R7710K

R753.3K

TR26A933

R743.3K

R762.2K

F-GND

MOUNTING HOLE

+5V

[C41]

C420.022µ

JC2

C370.1µ

TR27C1740

R60IK

JP3

SW1RA74.7K x 8

+5V

+5V

R844.7K

TR29C1740

R856.8K

SW6SLIDE SW

C

7

14

13

8

62

64

74

OUTA 0

20

26

19

17

16

15

14

12

11

10

HD 9

HDEN

28RD

27WR

25RES

C380.022µ

HD 8

HD 7

HD 6

HD 5

HD 4

HD 3

HD 2

HD 1

29

30

32

33

34

35

36

37

DB 7

DB 6

DB 5

DB 4

DB 3

DB 2

DB 1

DB 0

47

31

46

45

44

43

42

AB 17

V DD

+5V

AB 16

AB 15

AB 14

AB 13

AB 0

OUTA 2

IO 1

OUTA 1

DIN 0

DIN 1

DIN 2

DIN 3

DIN 4

DIN 5

DIN 6

DIN 7

1

2

3

4

5

6

7

8

72

71

70

69

68

67

66

SW4RA64.7K x 4

61 INB 0

IO 0

INB 1

INB 2

1

2

3

4

60

59

58

24

12

15

17

13

14

18

7NC x 4

5VR703.3K

D8 IS1588

D9 IS1588

+

+13 5

2 6

4+

+

16

C3522µ/16V

C274.7µ/25V

C314.7µ/25V

C2922µ/16V

C110.01µ

+5V +5V

R491.5K

IC3

M51953

73V DD

80MODE 0

5V SS

13V SS

18V SS

A SIDE B

C

5

1

3

4

Page 57: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 53 –

IC2

CN1

CN2

58TXD AN 0

3 1 R61 8.2K

4.7KR622

AN 14 3 R63 8.2K

4.7KR644

AN 25 5 R65 8.2K

4.7KR666

AN 36

AN 47

AN 58

+5VR244.7K

R194.7K

J1

J2

R891K

R208.2K

7 R67 8.2K

4.7KR688

56

64

21

1

2

55

32

20

61

62

22

JC2R8610K

+5V

C847OP

C1610OP

+5V

C1710OP

C90.022µ

RXD

+5V

NMI

EA

VREF

A GAND

TO4

RD

WR

RES

V SS

V cc

31

30

29

28

27

26

RA310K x 8

25

249

8

7

6

5

4

3

2D 7

D 6

D 5

D 4

D 3

D 2

D 1

D 0

6

RA2IK x 9

330 x 9 D2041 x 9

+24V

M-GND

R43 TR193

7 R38 TR141

4 R42 TR1813

8 R44 TR202

2 R41 TR1712

9 R39 TR154

3 R36 TR1214

10 R40 TR166

5 R37 TR1310

HD 1

8 HD CMN

7 HD CMN

5 HD CMN

HD 2

HD 3

HD 4

HD 5

HD 6

HD 7

HD 8

HD 9

9+5V

+24V

THERMISTOR

11 THERMISTOR

P3359

R910K

TR3C1740

R810K

R7810K

TR2B1359

R72.7(2W)

+VL

D2ISR35-100

6 LF-CMN B

5 LF-CMN A

1K x 4

4.7K x 3

R281 LF-fl 1

R292 LF-fl 2

R303 LF-fl 3

R31

7

5

9

3

1 10M-GND

6

4

8

24 LF-fl 4

INT 118 R32

R21

C5 C3 C2 C1

+5V

R23

R22

47K

68K

33K

16 TIMING SIG 1

P609 R25

17 TIMING SIG 2

P6110 R26

13 H.P SIG

P6312

R274.7K

+5V

+5V

+5V

TR30C1740

P6211

P3157 R13 4.7K R12 4.7K

[R14]

[TR4]

[R15]

470P x 4

[C4]

R3310K

TR9C1740

R353.3K TR8

A933

R346.8K

TR10D882

TR11B1359

+5V

+24V

M-GND

+24

[R87]

+5V

14 VALIDATION SIG

18 GND

15 NC

19

[20]

NC

12 +5V

7 CR MOTOR (+)

8 CR MOTOR (+)

9 CR MOTOR (-)

10 CR MOTOR (-)

11

[21]

NC

+5VP34

60

P4253

P4354

P3763

P8017

P8219

(R10) (R11)

359A 0

368A 1

377A 2

386A 3

395A 4

404A 5

CA2100P x 8

CA1100P x 8

CA1

CA2

CA1

CA2

419A 6

423A 7

438A 8

442A 9

457A 10

466A 11

475A 12

484A 13

493A 14

502A 15

51A 16

52C19

(C18)

100PA 17

X1 X2

RA84.7K x 4

+5V

SW3

TA1

MP4001

R4822K

R472.2K

R4610K

+5V

TR21A950

TR22C1740

C151.5µ

C130.01µ

R4510K –1%

BSIDE A

D

P7013

P7114

P7215

P7316

(R16)

Page 58: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 54 –

CN11

IC6LS06

CN10

SPX-G/A

2725627512P-ROM

3+5V

1+24V

2M-GND

4S-GND

1+5V

2ON-LINE SW

6FEED SW

7

3POWER LAMP

4ALARM LAMP

5ON-LINE LAMP

8GND

J3

+5V

38C26100P

C30100P

C32100P

CA310OP x 8

C28100P

D5IS1588

+5V

BZQMB111P

R59330

ROM

40RAM

39CG

41

9

PSOE

+5V+5V

28RA510K x 8

RA410K x 8

10 7(A0)9A 0 D0

8D1

9D2

4D3

3D4

2D5

5D6

6

11

12

13

15

16

17

18

19

14

D7

20CE

22OE

9(A1)8A 1

8(A2)7A 2

7(A3)6A 3

6(A4)5A 4

5(A5)4A 5

4(A6)3A 6

3(A7)2A 7

+5V25(A8)6

A 824(A9)7

A 921(A10)9

A 1023(A11)8

A 112(A12)4

A 1226(A13)5

A 1327(A14)

(A15)

3A 14

12

+5VB A

C

BA

C

JP2

A 15

SW2RA94.7K x 8

49 INC 0

INC 1

INC 2

INC 3

INC 4

INC 5

INC 6

INC 7

INA 0

8

7

6

5

+VL

+5V

+24V

M-GND

JC1

+5V+5V

4.7K x 3

+5V

R584.7K

+5V

R5710K

+5V

R5610K

4.7K x 3R6

INA 1+5V R4

INA 2+5V

[C45] [C46]

10 11

12 13

R2

R5

R3

R1

C10, C20C24, C25C33, C230.022µF x 6

4

3

2

1

50

51

53

54

55

56

57

77

78

79

OUTA 376

IND 075

(A16)

(A17)

V SS52

IC5

2M ROM

+5V

1 32

12A 0 D0

D1

D2

D3

D4

D5

D6

13

14

15

17

18

19

20

21

16D7

22CE

A1824

31

OE

11A 1

10A 2

9A 3

8A 4

7A 5

6A 6

5A 7

27A 8

26A 9

23A 10

25A 11

4A 12

28A 13

29A 14

3

+5V

+5V

BA

(A13)

JP6

JP1 C

A 152

A 1630

A 17

[IC4]

6264-10051832-120

14 28

10A 0 D0

D1

D2

D3

D4

D5

D6

11

12

13

15

16

17

18

19D7

27WE

22OE

20CE

9A 1

8A 2

7A 3

6A 4

5A 5

4A 6

3A 7

25A 8

24A 9

21A 10

23A 11

2A 12

26A 13

1A 14

IC1

OUTB 0

1OUTB 7

2OUTB 6

3OUTB 5

4OUTB 4

6OUTB 3

7OUTB 2

8OUTB 1

21ATC 0

22ATC 1

23ATC 2

24ATC 3

48KA 0

BZ

<Note 1> The unit of resistor and resistor array is " ", and no indication of wattage means 1/6W, 1/8W respectively.<Note 2> The unit of capacitor and capacitor array is "F", and no indication of voltage means 50V.<Note 3> The components in bracket [ ] are not installed on the board.<Note 4> The components in bracket ( ) depend on the printer type if it is installed or not on the board. Refer to parts list.

C SIDE D

A

N.C.

Page 59: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 55 –

TMP90C041F

CN5

CN7

CN6

CN3

[CN4]

[CN12]

JP7

4

3

5

6

7

8

9

RA1IK x 7

[R79]

[R80]

[TR7]

[TR6]

+24

REGI7824

+24V

FILM

C400.1µ

D4IDT139

TR24D2010

TR23D2010

D3ISR139

I 0G

1 3

2

1 REWINDER (+)

2

[22]

[23]

REWINDER (-)

3PERIPHERAL

4 +24V

+24V

2 EXT 1

5

1

3

2

4

5

EXT 2

1 F-GND

6 SW 1

1AUTO CUTTERF/P POSITION SIG

2 RESET SIG

3 GND

4 MOTOR

5 MOTOR

1 +5V

2 PAPER END SIG1

3 GND

1 +5V (NC)

2 PAPER END SIG2 (NC)

3

4

GND (NC)

BLACK MARK SENSOR (NC)

33 341

JC1

3

9.83M2

9 8

3 4

1 2

5 6

VS

+5VTR5A1115

R18100

C14Super Cap

R6922K TR25

C1740

R172.2K

+ +

C364.7µ25V

C12, C340.022µF x 2

13 314

7

11

C3910OP

VS VS

12

98 10

1

2

IC8HC00

IC8HC00

IC8HC00

46 5

IC8HC00

M-GND

M-GND

M-GND

M-GND+5V

F-GND

+5V

+5V

+5V

R82330

TR1D2010

R81330

R83330

R7310K

TR28C1740

R714.7K

R7233K

+5V

R5147K

C43

7

R52 3.3K

+24VC220.1µ

C210.1µ

R53 3.3K

R54 15K

R55 15K

10

1 TH3C10

+24V

M-GND

3

9

5

6

2

8

4

C44

R5047K

C70.022µ

C60.022µ

+5V

TA2

DSIDE C

B

IC6LS06

0.022µ x 2

Page 60: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 56 –

IC1 08221043 SRAM 6264FP-100NS*EL 1IC2 08250009 CPU TMP90C041F 1IC3 08200109 IC-RESET M51953BL 1IC4 09110077 IC SOCKET ICS-32-2T 1IC5 08222026 EPROM 27256-150NS 1 SP3S.F.**

09110024 IC SOCKET ICS-28-2T 1IC6 08210127 TTL IC 74LS06FP*EL 1IC7 08240019 GATE ARRAY LC92011B-SP300 1IC8 08231065 CMOS 74HC00FP*EL 1IC9 08200157 IC-I/F ADM232LJR*SOL16 1REG1 08202011 IC-REG UPC7824 1TA1 07650056 TRANSISTOR ARRAY UPA1428AH 1TA2 07650037 TRANSISTOR ARRAY TH3C10 1TR1 07320101 TRANSISTOR 2SD2010 1TR2 07113591 TRANSISTOR 2SB1359 1TR3 07227853 TRANSISTOR 2SC1740SE 1TR4 NOT MOUNTEDTR5 07019931 TRANSISTOR 2SA1993F 1TR6-7 NOT MOUNTEDTR8 07011752 TRANSISTOR 2SA1266* 1TR9 07227853 TRANSISTOR 2SC1740SE 1TR10 07308821 TRANSISTOR 2SD882P 1TR11 07113591 TRANSISTOR 2SB1359 1TR12-20 07320411 TRANSISTOR 2SD2041 9TR21 07009502 TRANSISTOR 2SA950 1TR22 07227853 TRANSISTOR 2SC1740SE 1TR23-24 07320101 TRANSISTOR 2SD2010 2TR25 07227853 TRANSISTOR 2SC1740SE 1TR26 07011752 TRANSISTOR 2SA1266* 1TR27-29 07227853 TRANSISTOR 2SC1740SE 3TR30 07227853 TRANSISTOR 2SC1740SE 1D1 NOT USEDD2 08000044 DIODE 1SR139-100AT 1D3-4 08000044 DIODE 1SR139-100AT 2D5 08000096 DIODE 1S2076A*A 1D6-7 NOT USEDD8-9 08000096 DIODE 1S2076A*A 2RA1 06581021 RESIS. ARRAY 1 K-OHM 1/8W 8EL 1RA2 06581022 RESIS. ARRAY 1 K-OHM 1/8W 9EL 1RA3-5 06581032 RESIS. ARRAY 10 K-OHM 1/8W 8EL 3RA6 06584721 RESIS. ARRAY 4.7K-OHM 1/8W 4EL 1RA7 06584723 RESIS. ARRAY 4.7K-OHM 1/8W 8EL 1RA8 06584721 RESIS. ARRAY 4.7K-OHM 1/8W 4EL 1RA9 06584723 RESIS. ARRAY 4.7K-OHM 1/8W 8EL 1R1-6 06054725 RD RESISTOR 4.7 K-OHM 1/6W 6R7 06200271 RN RESISTOR 2.7 OHM 2W 2% 1R8-9 06051034 RD RESISTOR 10 K-OHM 1/6W 2R10-11 NOT MOUNTEDR12-13 06054725 RD RESISTOR 4.7 K-OHM 1/6W 2R14-16 NOT MOUNTEDR17 06052224 RD RESISTOR 2.2 K-OHM 1/6W 1R18 06051014 RD RESISTOR 100 OHM 1/6W 1R19 06054725 RD RESISTOR 4.7 K-OHM 1/6W 1R20 06058224 RD RESISTOR 8.2 K-OHM 1/6W 1R21 06054734 RD RESISTOR 47 K-OHM 1/6W 1R22 06253334 RN RESISTOR 33 K-OHM 1/6W 1% 1

DRWG.NO. PARTS NO. PARTS NAME Q'TY REMARKS

8.4 Parts List

Page 61: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 57 –

R23 06056834 RD RESISTOR 68 K-OHM 1/6W 1R24-27 06054725 RD RESISTOR 4.7 K-OHM 1/6W 4R28-31 06051025 RD RESISTOR 1 K-OHM 1/6W 4R32 06054725 RD RESISTOR 4.7 K-OHM 1/6W 1R33 06051034 RD RESISTOR 10 K-OHM 1/6W 1R34 06056824 RD RESISTOR 6.8 K-OHM 1/6W 1R35 06053324 RD RESISTOR 3.3 K-OHM 1/6W 1R36-44 06053314 RD RESISTOR 330 OHM 1/6W 9R45 06251034 RN RESISTOR 10 K-OHM 1/6W 1R46 06051034 RD RESISTOR 10 K-OHM 1/6W 1R47 06052224 RD RESISTOR 2.2 K-OHM 1/6W 1R48 06052234 RD RESISTOR 22 K-OHM 1/6W 1R49 06051525 RD RESISTOR 1.5 K-OHM 1/6W 1R50-51 06054734 RD RESISTOR 47 K-OHM 1/6W 2R52-53 06053324 RD RESISTOR 3.3 K-OHM 1/6W 2R54-55 06051535 RD RESISTOR 15 K-OHM 1/6W 2R56-57 06051034 RD RESISTOR 10 K-OHM 1/6W 2R58 06054725 RD RESISTOR 4.7 K-OHM 1/6W 1R59 06053314 RD RESISTOR 330 OHM 1/6W 1R60 06051025 RD RESISTOR 1 K-OHM 1/6W 1R61 06058224 RD RESISTOR 8.2 K-OHM 1/6W 1R62 06054725 RD RESISTOR 4.7 K-OHM 1/6W 1R63 06058224 RD RESISTOR 8.2 K-OHM 1/6W 1R64 06054725 RD RESISTOR 4.7 K-OHM 1/6W 1R65 06058224 RD RESISTOR 8.2 K-OHM 1/6W 1R66 06054725 RD RESISTOR 4.7 K-OHM 1/6W 1R67 06058224 RD RESISTOR 8.2 K-OHM 1/6W 1R68 06054725 RD RESISTOR 4.7 K-OHM 1/6W 1R69 06052234 RD RESISTOR 22 K-OHM 1/6W 1R70 06053324 RD RESISTOR 3.3 K-OHM 1/6W 1R71 06054725 RD RESISTOR 4.7 K-OHM 1/6W 1R72 06053334 RD RESISTOR 33 K-OHM 1/6W 1R73 06051034 RD RESISTOR 10 K-OHM 1/6W 1R74-75 06053324 RD RESISTOR 3.3 K-OHM 1/6W 2R76 06052224 RD RESISTOR 2.2 K-OHM 1/6W 1R77-78 06051034 RD RESISTOR 10 K-OHM 1/6W 2R79-80 NOT MOUNTEDR81-83 06053314 RD RESISTOR 330 OHM 1/6W 3R84 06054725 RD RESISTOR 4.7 K-OHM 1/6W 1R85 06056824 RD RESISTOR 6.8 K-OHM 1/6W 1R86 06051034 RD RESISTOR 10 K-OHM 1/6W 1R87 NOT MOUNTEDR88 06054725 RD RESISTOR 4.7 K-OHM 1/6W 1R89 06051025 RD RESISTOR 1 K-OHM 1/6W 1CA1-3 05651012 CAPA. ARRAY 100PF 50V 8EL 3C1 05154714 CERA. CAPA. 470PF 50V 1C2-3 05154714 CERA. CAPA. 470PF 50V 2C4 NOT MOUNTEDC5 05154714 CERA. CAPA. 470PF 50V 1C6-7 05152234 CERA. CAPA. 0.022UF 50V 2C8 05154714 CERA. CAPA. 470PF 50V 1C9-10 05152234 CERA. CAPA. 0.022UF 50V 2C11 05151033 CERA. CAPA. 0.01UF 50V 1C12 05152234 CERA. CAPA. 0.022UF 50V 1C13 05151033 CERA. CAPA. 0.01UF 50V 1C14 05994733 BACK-UP CAPA. EECS0HD473V 1

DRWG.NO. PARTS NO. PARTS NAME Q'TY REMARKS

Page 62: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 58 –

C15 05131044 CERA. CAPA. 0.1UF 25V 1C16-17 05151015 CERA. CAPA. 100PF 50V 2C18 NOT MOUNTEDC19 05151015 CERA. CAPA. 100PF 50V 1C20 05152234 CERA. CAPA. 0.022UF 50V 1C21-22 05151044 CERA. CAPA. 0.1UF 50V 2C23 NOT MOUNTEDC24 05532234 CAPACITOR 0.022UF 25V 1C25 05152234 CERA. CAPA. 0.022UF 50V 1C26 05151015 CERA. CAPA. 100PF 50V 1C27 05051057 CHEM. CAPA. 1UF 50V 1C28 05151015 CERA. CAPA. 100PF 50V 1C29 05051057 CHEM. CAPA. 1UF 50V 1C30 05151015 CERA. CAPA. 100PF 50V 1C31 05051057 CHEM. CAPA. 1UF 50V 1C32 05151015 CERA. CAPA. 100PF 50V 1C33-34 05152234 CERA. CAPA. 0.022UF 50V 2C35 05051057 CHEM. CAPA. 1UF 50V 1C36 05034756 CHEM. CAPA. 4.7UF 25V 1C37 05131044 CERA. CAPA. 0.1UF 25V 1C38 05152234 CERA. CAPA. 0.022UF 50V 1C39 05151015 CERA. CAPA. 100PF 50V 1C40 05251044 FILM CAPA. 0.1UF 50V 1C41 NOT MOUNTEDC42 05252232 FILM CAPA. 0.022UF 50V 1C43-46 NOT MOUNTEDSW1-3 09090034 DIP SWITCH KSS08-1 3SW4 09090033 DIP SWITCH KSS04-1 1SW5-6 09100428 CONNECTOR IMSA9210B1-03GF 2BZ1 45060201 BUZZER QMB-111P 1XTAL 09250037 CERA. OSCILLATOR CST9.83MT 1CN1 09100400 CONNECTOR HLEM14S-1 1CN2 09100419 CONNECTOR HLEM19S-1 1CN3 09100269 CONNECTOR 5483-03A 1CN4 NOT MOUNTEDCN5 09100270 CONNECTOR 5483-02A 1CN6 09100268 CONNECTOR 5483-05A 1CN7 09100421 CONNECTOR 52065-6645 1CN8 09100602 CONNECTOR DT11321-R5T 1CN9 09100430 CONNECTOR IL-W24S-SD 1CN10 09100420 CONNECTOR B8B-PH-K 1CN11 09100317 CONNECTOR 5483-04A 1JC1-2 80924670 WIRE 20UL1015BLK100 2- 80702680 CABLE UNIT 14X265 SP312 1 OPTION *1

80702690 CABLE UNIT 19X265 SP312 1 OPTION *280703420 CABLE UNIT 4X510C BD300F 1 OPTION *380703430 CABLE UNIT 8X510C BD300F 1 OPTION *480703790 CABLE UNIT 14X100 BD300F 1 OPTION *580703800 CABLE UNIT 19X100 BD300F 1 OPTION *680703920 CABLE UNIT 14X330 BD300F 1 OPTION80703930 CABLE UNIT 19X330 BD300F 1 OPTION87219110 CABLE SET BD300F 1 OPTION :NOTE187219120 CABLE SET 100 BD300F 1 OPTION :NOTE287219062 CONTROL BOARD BD300K 1 OPTION :RS-422A87219051 CONTROL BOARD BD300L 1 OPTION :CURRENT LOOP

DRWG.NO. PARTS NO. PARTS NAME Q'TY REMARKS

Note1 : This cable set consists of four cables(*1 to *4)Note2 : This cable set consists of four cables(*3 to *6)

Page 63: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 59 –

9. APPENDIX9-1. Control Code List

Control Codes Used in Charater Setting

Control codes Hexadecimal codes Function Page

<ESC> “R” n 1B 52 n Select international character set 23

<ESC> “6” 1B 36 Select IBM character set #2 23

<ESC> “7” 1B 37 Select IBM character set #1 23

<ESC> “M” 1B 4D Select font matrix 7 × 9 (half-dot) 24

<ESC> “P” 1B 50 Select font matrix 5 × 9 (2 pulses-1 dot) 24

<ESC> “:” 1B 3A Select font matrix 5 × 9 (3 pulses-1 dot) 25

<SO> 0E Select expanded character mode 25

<DC4> 14 Cancel expanded character mode 25

<ESC> “W” “1” 1B 57 31Select expanded character mode 25

<ESC> “W” <1> 1B 57 01

<ESC> “W” “0” 1B 57 30Cancel expanded character mode 25

<ESC> “W” <0> 1B 57 00

<ESC> “E” 1B 45 Select emphasized print mode 26

<ESC> “F” 1B 46 Cancel emphasized print mode 26

<ESC> “-” “1” 1B 2D 31Select underline mode 26

<ESC> “-” <1> 1B 2D 01

<ESC> “-” “0” 1B 2D 30Cancel underline mode 26

<ESC> “-” <0> 1B 2D 00

<ESC> “_” “1” 1B 5F 31Select overline mode 26

<ESC> “_” <1> 1B 5F 01

<ESC> “_” “0” 1B 5F 30Cancel overline mode 26

<ESC> “_” <0> 1B 5F 00

<ESC> “4” 1B 34 Select highlighted print mode 27

<ESC> “5” 1B 35 Cancel highlighted print mode 27

<SI> 0F Select inverted print mode 27

<DC2> 12 Cancel inverted print mode 27

Control Codes Used in Line Spacing

Control codes Hexadecimal codes Function Page

<LF> 0A Line feed 28

<CR> 0D Line feed (same as LF) 28

<ESC> “z” “1” 1B 7A 31Set 1/6 inch line feed 28

<ESC> “z” <1> 1B 7A 01

<ESC> “0” 1B 30 Set 1/8 inch line feed 28

<ESC> “a” n 1B 61 n Feed paper n lines 28

Page 64: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 60 –

Control Codes Used for Page Layout

Control codes Hexadecimal codes Function Page

<FF> 0C Page feed (form feed) 29

<ESC> “C” n 1B 43 n Set page length at n lines 29

<ESC> “C” <0> n 1B 43 00 n Set page length at n inches 29

<VT> 0B Execute vertical tab 29

<ESC> “B” n1 n2 1B 42 n1 n2 Set vertical tab positions 30

<ESC> “N” n 1B 4E n Set bottom margin 30

<ESC> “O” 1B 4F Cancel bottom margin 30

<ESC> “l” n 1B 6C n Set left margin 30

<ESC> “Q” n 1B 51 n Set right margin 31

<HT> 09 Execute the horizontal tab 31

<ESC> “D” n1 n2 1B 44 n1 n2 Set horizontal tab positions 31

Control Codes Used for Graphics Printing

Control codes Hexadecimal codes Function Page

<ESC> “1” 1B 31 Set 7/72 inch line feed 32

<ESC> “A” n 1B 41 n Define n/72 inch line feed 32

<ESC> “2” 1B 28 Set n/72 inch line feed 32

<ESC> “J” n 1B 4A n One time line feed of n/72 inch 32

<ESC> “z” “0” 1B 7A 30Set 1/12 inch line feed 32

<ESC> “z” <0> 1B 7A 00

<ESC> “y” n 1B 79 n Set n/144 inch line feed 32

<ESC> “3” n 1B 33 n Set n/216 inch line feed 32

<ESC> “K” n1 <0> 1B 4B n1 00 8 dot single density bit image 33

<ESC> “L” n1 n2 1B 4C n1 n2 8 dot double density bit image 34

<ESC> “h” “1” 1B 68 31Select vertical expanded character mode 35

<ESC> “h” <1> 1B 68 01

<ESC> “h” “0” 1B 68 30Cancel vertical expanded character mode 35

<ESC> “h” <0> 1B 68 00

Page 65: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 61 –

Control Codes Used for Download Characters

Control codes Hexadecimal codes Function Page

<ESC> “&” <0> n1 n2 1B 26 00 n1 n2 Define of download characters 36

<ESC> “%” “1” 1B 25 31Enable download character set 37

<ESC> “%” <1> 1B 25 01

<ESC> “%” “0” 1B 25 30Disable download character set 37

<ESC> “%” <0> 1B 25 00

Control Codes Used for Peripheral Units

Control codes Hexadecimal codes Function Page

<ESC> <BEL> n1 n2 1B 07 n1 n2 Adjust drive pulse width for peripheral unit 1 39

<BEL> 07 Deferred drive command for peripheral unit 1 39

<FS> 1C Immediate drive command for peripheral unit 1 39

<SUB> 1A Immediate drive command for peripheral unit 2 40

<EM> 19 Immediate drive command for peripheral unit 2 40

Other Control Codes

Control codes Hexadecimal codes Function Page

<RS> 1E Sound buzzer 40

<CAN> 18 Cancel print data in buffer 40

<DC3> 13 Set deselect mode 40

<DC1> 11 Set select mode 41

<ESC> “U” “1” 1B 55 31Select uni-directional print mode 41

<ESC> “U” <1> 1B 55 01

<ESC> “U” “0” 1B 55 30Select bi-directional print mode 41

<ESC> “U” <0> 1B 55 00

<ESC> “@” 1B 40 Initialize printer 42

<ENQ> 05 Enquiry 42

<STX> 02 Enter STX-ETX mode 42

<ETX> 03 Terminate STX-ETX mode 42

<GS> data <LF> 1B data 0A Select validation printing 43

<ESC> “d” “0” 1B 64 30Trigger auto-cutter drive (full cut) 43

<ESC> “d” <0> 1B 64 00

<ESC> “d” “1” 1B 64 31Trigger auto-cutter drive (partial cut) 43

<ESC> “d” <1> 1B 64 01

Page 66: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 62 –

9-2. Character code table

9.2.1 U.S.A. & Europe (DIP SW2-1: ON, SW2-2: ON)

Page 67: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 63 –

Page 68: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 64 –

9.2.2 IBM Character Set #1 (DIP SW2-1: OFF, SW2-2: ON)

Page 69: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 65 –

Page 70: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 66 –

9.2.3 IBM Character Set #2 (DIP SW2-1: ON, SW2-2: OFF)

Page 71: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 67 –

Page 72: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 68 –

9.2.4 JAPAN (DIP SW2-1: OFF, SW2-2: OFF)

Page 73: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 69 –

Page 74: Bd300fd 24 Bxcontrolboardspecification Operationmanual

– 70 –

9.2.5 International Character Sets

Page 75: Bd300fd 24 Bxcontrolboardspecification Operationmanual

2000.08.20

Printed in Japan, 80822236

OVERSEAS SUBSIDIARY COMPANIESSTAR MICRONICS AMERICA, INC.1150 King Georges Post Road, Edison,NJ 08837-3729 U.S.A.Tel : 732-623-5555Fax: 732-623-5590

ELECTRONIC PRODUCTS DIVISIONSTAR MICRONICS CO., LTD.536 Nanatsushinya,Shimizu, Shizuoka, 424-0066 JapanTel : 0543-47-0112Fax: 0543-48-5013

Distributed by

STAR MICRONICS U.K. LTD.Star House, Peregrine BusinessPark, Gomm Road, High Wycombe,Bucks, HP13 7DL, U.K.Tel : 01494-471111Fax: 01494-473333

Please access the following URLhttp://www.star-micronics.co.jp/service/frame_sp_spr_e.htmfor the lastest revision of the manual.