Upload
ngonhi
View
221
Download
2
Embed Size (px)
Citation preview
Belden Industrial Ethernet Cabling
July 2009
Belden Industrial Data Cable Solutions
• Belden is a known leader in signal transmission technology, we
manufacture our products to the industry’s highest standards of
quality, utilizing the most advanced equipment, systems, controls
and processes available.
• The industrial environment demands the utmost in reliability and
performance; Belden’s comprehensive line of industrial cabling
solutions has been specifically designed with this in mind.
• Extensive cable designs, gauge sizes, insulation materials, shielding
configuration and jacket material possibilities ensure complete
confidence in product choice for the multitude of cabling applications
subject to the demands of this typically harsh environment.
Belden Industrial Data Cable Solutions
• An extensive range of purpose designed cables for use in the
extreme industrial environment and lasting durability in application.
• An excellent range of cable solutions to support all types of industrial
communications protocols.
• Wide temperature performance to withstand exposure to changing
conditions.
• Various heavy duty jacket combinations for UV, oil and other
chemical solvent resistance.
• Low smoke, zero-halogen cable options to international standards –
a prerequisite in many environments.
• Innovative shielding techniques for maximum protection in EMI
(Electromagnetic interference) and RF (Radio frequency) spectrums.
• Designed and approved to international standards for quality and
safety assurance in the global environment.
Belden Industrial Data Cable Solutions
• Belden offer a comprehensive range of industrial data cabling
for a wide range of industrial communications protocols.
• A reputation for quality and reliability has seen Belden cables
being used in industrial communication applications for many
years.
• The Belden Fieldbus range is complemented by an extensive
range of Industrial Ethernet cabling offering the same superior
performance for ethernet based applications.
• Belden’s full range of Industrial Data Solutions® includes
cables for all types of Fieldbus applications such as Profibus,
DeviceNet™ Modbus and the Ethernet variants such as
Profinet and EtherNet/IP™.
Industrial Ethernet Technology
• The use of ethernet-based networking, already in place in the
office environment, to perform similar data communications on
the factory floor has grown in recent years.
• A major benefit of Industrial Ethernet is its’ interoperability with
the traditional Fieldbus systems, it is therefore growing rapidly in
existing industrial automation installations.
• In additional to the system integration benefits, Industrial
Ethernet offers operational benefits such as cost, data volume
and transmission speed improvements to bring increased
production capacity and more efficient operations.
• Industrial Ethernet provides the missing link from the
management functions to the devices on the factory
floor to combine industrial performance with the
consistency and transparency of corporate
communication.
Belden Industrial Ethernet Cabling Range
Belden offer a choice of two ranges according to Ethernet protocol
being used:
• Profinet Cabling
A range of copper cabling conforming to PROFINET, the industrial
ethernet standard managed by PI International.
Suitable for use in the industrial environment, cabling is SF/UTP and
Cat 5e performance.
Green RAL 6018 Cable Jacket.
• Standard Industrial Ethernet Cabling
A range of copper cabling to support industrial ethernet and
associated networks such as EtherNet/IP™. Suitable for use in the
industrial environment, cabling is SF/UTP for Cat 5e and S/FTP for
Cat 7 performance.
Black Cable Jacket.
Belden Profinet Industrial Ethernet Cables
• Main features:
• Profinet compliant cable in accordance with Profinet PN-Cabling-Guide_2252_V200_May2007
• Universal conductor AWG 22
• Cat 5e transmission performance
• Star quad conductor design
• Overall braided shield (> 85% coverage)
• SF/UTP (Overall Foil Braided Shield / Unshielded Twisted Pair)
• Green RAL 6018 cable jacket
• Choice of PVC / FRNC / PUR cable jacket
• 3 Main designation types
– Type A / Type B / Type C
Belden Profinet Cable Type A / Type B
Star Quad Design
Cat 5e Transmission Performance
Type A for stationary applications (AWG 22/1 Solid Conductor)
There will be no movement after installation
Type B for flexible applications (AWG 22/7 Stranded Conductor)
Will be subject to occasional movement or vibration
Overall foil and braided shield(> 85% coverage)
Conductor AWG 22Green RAL 6018 cable jacket
Filler
Insulation
Bedding
Belden Profinet Cable – Jacket Options
• Cable types A and B have different jacket options to suit the specific industrial environment and application:
PVC: Minimum requirement for the general industrial environment
� Good flame, heat and weather resistance
� Oil resistant
X Contains halogens
X Poor gasoline, solvent, and radiation resistance
FRNC: Good protection in the harsh industrial environment
� Halogen free, premium FRNC compound
� Flame Retardant Non Corrosive
� Good flexibility
� Oil resistant
PUR: For high protection in the extreme industrial environment
� Superior mechanical strength
� Excellent flexibility, oil resistance
� Halogen free
X Generally poor flame resistance
� Belden jacket has flame resistance IEC 60332-1
� Non cross linked weld-splatter resistant jacket available on request
Belden Profinet Cable Type C
Profinet Cabling Type C
• Type C for highly flexible, continuous movement applications,
permanent movement, vibration or torsion
Trailing: Used for high mechanical stress, especially in
applications with frequent winding and
unwinding.
Torsion: Flexible robotic cables designed for twisting
applications on robotic arms and other
applications that require rotary motion
AWG 22/19 Stranded Conductor
PUR Cable jacket to withstand these more severe applications
Belden Standard Industrial Ethernet Cables
• Main features:
• Conductor sizes AWG 23 / 24 / 26
• Solid and stranded conductors for different application types
• Cat 5e and Cat 7 transmission performance
• Four pair and two pair conductor design
• Overall braided shield (> 80% coverage)
• SF/UTP (Overall Foil Braided Shield / Unshielded Twisted Pair)
• S/FTP (Overall Shielded / Foil Shielded Twisted Pair)
• Black Cable jacket
• 3 Main designation types
(Permanent / Flexible / Trailing -Torsion)
Belden Standard Industrial Ethernet 4 Pair Cat 5e
• SF/UTP (Overall Foil Braided Shield / Unshielded Twisted Pair)
Cat 5e
Solid conductor AWG 24/1 for stationary applications
There will be no movement after installation
Stranded conductor AWG 26/7 for flexible applications
Will be subject to occasional movement or vibration
4 Pair design (unshielded twisted pair)
Overall foil and braided shield (> 80% coverage)
2 Twisted, polypropylene insulated conductors
Belden Standard Industrial Ethernet 4 Pair Cat 5e
• Type C for highly flexible, continuous movement applications, permanent movement, vibration or torsion
Trailing: Used for high mechanical stress, especially in applications with frequent winding and unwinding.
Torsion: Flexible robotic cables designed for twisting applications on robotic arms and other applications that require rotary motion
AWG 26/19 Stranded Conductor
PUR Cable jacket to withstand these more severe applications
Belden Standard Industrial Ethernet 4 Pair Cat 7
• S/FTP (Overall Braided Shielded / Foil Shielded Twisted Pair)
Cat 7
4 Pair design (Individually foil shielded twisted pair)
Overall braided shield (> 65% coverage)
2 Twisted, foam–skin PE insulated conductors
Solid conductor AWG 23/1 for stationary applications
There will be no movement after installation
Stranded conductor AWG 26/7 for flexible applications
Will be subject to occasional movement or vibration
Belden Standard Industrial Ethernet 2 Pair Cat 5e
• SF/UTP (Overall Foil Braided Shield / Unshielded Twisted Pair)
Cat 5e
2 Pair design (unshielded twisted pair)
Overall braided shield (> 85% coverage)
Solid conductor AWG 24/1 for stationary applications
There will be no movement after installation
Stranded conductor AWG 26/7 for flexible applications
Will be subject to occasional movement or vibration
Standard Industrial Ethernet Cable – Jacket Options
As with Profinet, stationary cable applications and flexible cable
applications have different jacket options to suit the specific
industrial environment:
PVC : Minimum requirement for the general industrial
environment
FRNC : Good protection in the harsh industrial environment
PUR : For high protection in the extreme industrial
environment
Cable types C for trailing and torsion applications are only
available with PUR jacket to suit these extreme applications.
PVC Cable Jacket Premium FRNC Cable Jacket PUR Cable Jacket
Lower cost / performance Higher cost / performance
Belden Profinet Cat 5e Cabling Range Overview
Green
RAL 6018
PURQuadStranded (19)225eProfinet Torsion
(AWG22/19) PUR
Type C
Torsion
Available
late 2009
Green
RAL 6018
PURQuadStranded (19)225eProfinet Trailing
(AWG22/19) PUR
Type C
Trailing
70008PU
Green
RAL 6018
PURQuadStranded (7)225eProfinet Type B
(AWG22/7) PUR
Type B70007PU
Green
RAL 6018
Premium
FRNC
QuadStranded (7)225eProfinet Type B
(AWG22/7) FRNC
Type B70007NH
Green
RAL 6018
PVCQuadStranded (7)225eProfinet Type B
(AWG22/7) PVC
Type B70007E
Green
RAL 6018
PURQuadSolid (1)225eProfinet Type A
(AWG22/1) PUR
Type A70006PU
Green
RAL 6018
Premium
FRNC
QuadSolid (1)225eProfinet Type A
(AWG22/1) FRNC
Type A70006NH
Green
RAL 6018
PVCQuadSolid (1)225eProfinet Type A
(AWG22/1) PVC
Type A70006E
Cable Jacket
Colour
Cable
Jacket
Conductor
Design
Conductor
Type
AWGCategoryItem DescriptionApplication
Type
Belden
Item Code *
* Cable Jacket “E” (PVC), “NH” (FRNC), “PU” (PUR)
Belden Cat 5e Standard Industrial Ethernet (4 Pair) Cabling Range Overview
BlackPUR4 PairStranded (19)265eIndus 4PR Torsion
(AWG26/19) PUR
TorsionAvailable
late 2009
BlackPUR4 PairStranded (19)265eIndus 4PR Trailing
(AWG26/19) PUR
Trailing74003PU
BlackPUR4 PairStranded (7)265eIndus Cat 5e 4PR
(AWG26/7) PUR
Flexible74002PU
BlackPremium
FRNC
4 PairStranded (7)265eIndus Cat 5e 4PR
(AWG26/7) FRNC
Flexible74002NH
BlackPVC4 PairStranded (7)265eIndus Cat 5e 4PR
(AWG26/7) PVC
Flexible74002E
BlackPUR4 PairSolid (1)245eIndus Cat 5e 4PR
(AWG24/1) PUR
Permanent74001PU
BlackPremium
FRNC
4 PairSolid (1)245eIndus Cat 5e 4PR
(AWG24/1) FRNC
Permanent74001NH
BlackPVC4 PairSolid (1)245eIndus Cat 5e 4PR
(AWG24/1) PVC
Permanent74001E
Cable Jacket
Colour
Cable
Jacket
Conductor
Design
Conductor
Type
AWGCategoryItem DescriptionApplication
Type
Belden
Item Code *
* Cable Jacket “E” (PVC), “NH” (FRNC), “PU” (PUR)
Belden Cat 7 Standard Industrial Ethernet (4 Pair) Cabling Range Overview
BlackPUR4 PairStranded (7)267Indus Cat 7 4PR
(AWG26/7) PUR
Flexible74005PU
BlackPUR4 PairSolid (1)237Indus Cat 7 4PR
(AWG23/1) PUR
Permanent74004PU
BlackPremium
FRNC
4 PairSolid (1)237Indus Cat 7 4PR
(AWG23/1) FRNC
Permanent74004NH
BlackPVC4 PairSolid (1)237Indus Cat 7 4PR
(AWG23/1) PVC
Permanent74004E
Cable Jacket
Colour
Cable
Jacket
Conductor
Design
Conductor
Type
AWGCategoryItem DescriptionApplication
Type
Belden
Item Code *
* Cable Jacket “E” (PVC), “NH” (FRNC), “PU” (PUR)
Belden Cat 5e Standard Industrial Ethernet (2 Pair) Cabling Range Overview
BlackPUR2 PairStranded (7)265eIndus Cat 5e 2PR
(AWG26/7) PUR
Flexible72002PU
BlackPremium
FRNC
2 PairStranded (7)265eIndus Cat 5e 2PR
(AWG26/7) FRNC
Flexible72002NH
BlackPVC2 PairStranded (7)265eIndus Cat 5e 2PR
(AWG26/7) PVC
Flexible72002E
BlackPUR2 PairSolid (1)245eIndus Cat 5e 2PR
(AWG24/1) PUR
Permanent72001PU
BlackPremium
FRNC
2 PairSolid (1)245eIndus Cat 5e 2PR
(AWG24/1) FRNC
Permanent72001NH
BlackPVC2 PairSolid (1)245eIndus Cat 5e 2PR
(AWG24/1) PVC
Permanent72001E
Cable Jacket
Colour
Cable
Jacket
Conductor
Design
Conductor
Type
AWGCategoryItem DescriptionApplication
Type
Belden
Item Code *
* Cable Jacket “E” (PVC), “NH” (FRNC), “PU” (PUR)
Belden Industrial Ethernet Cable
• Belden Industrial Ethernet cables meet the following specifications:
• Flame resistance : IEC 60332-1
• Bundle Flame Test Cat C (Belden 74004NH only)
• Oil resistance : IEC 60811-2-1
• ISO / IEC 11801 Cat 5e / Cat 7
• Halogen Free :IEC 60754-1 (FRNC and PUR)
IEC 60754-2 (FRNC and PUR)
• Temperature range installing : - 5 to +50˚C
• Temperature range operating : -25 to +80˚C
• RoHS compliant
Belden Industrial Ethernet CableFeatures and Benefits
� A comprehensive range consisting 26 different cable designs
� Star quad twist cable design for Profinet cable for enhanced
communication performance
� 4 Pair and 2 Pair cable designs
� Choice of robust jacket grades for bulk cabling to suit application
and cost requirements in the harsh industrial environment
� High shield coverage to maintain signal integrity in the industrial
‘noisy’ environment
� Product reliability and consistent performance
� Customer specific cable and cord set design capabilities
� European manufacture and flexibility
� Armoured and application specific cable jackets available on
request, including non cross linked weld splatter resistant jacket
Belden Industrial Ethernet Cabling
July 2009