20
ROTANTA 460 Benchtop Centrifuges, non-refrigerated and refrigerated

Benchtop Centrifuges, non-refrigerated and refrigerated · from Hettich have been distinguished by the highest quality. They have responded to the fast-paced ... the centrifuge calculates

  • Upload
    tranque

  • View
    219

  • Download
    0

Embed Size (px)

Citation preview

ROTANTA 460

BenchtopCentrifuges,non-refrigeratedand refrigerated

2

Efficient, results -oriented workingprocesses are top priority in bothresearch and routine laboratories.Advanced laboratory technologymakes a significant contribution toshortening processing times.

For decades, ROTANTA centrifugesfrom Hettich have been distinguished by the highest quality. They have responded to the fast -pacedchanges in laboratory environments withthe continuous development of new,technically outstanding solutions.

The ROTANTA 460 models are carryingon this tradition of quality. Enhancedperformance and an extended range ofaccessories guarantee fast, trouble-freeoperation in daily laboratory use.

With a maximum capacity of 3 litres per run, they are proving themselves inclinics and laboratory centres, as well asin Life Science R&D departments.

For sample processing in clinical chem-istry, a wide selection of adapters areavailable to accommodate the mostvaried types of tubes.

Biotechnology, molecular biology andthe pharmaceutical industry value theROTANTA 460 especially for its auto-clavable and aerosol- tight accessories.

These versatile benchtop centrifugesfeature a filter plate rotor with a RCF of 6,446 for purifying DNA/RNA.

ROTANTA 460

Hettich manufactures high quality centrifuges. All stages from design to end productare continually subjected to strictestcontrols. Evidence is provided by correspondingcertificates.

The ISO 9001:2000 certificate accre-dited to the entire company proves the extreme care and responsibilityHettich puts into the manufacture ofcentrifuges and their accessories.

ROTANTA 460 - a class of its own

Imbalance switch-offAutomatic rotor recognitionCentrifuging chamber of stainless steelMetal housingLid locking and holding during rotor runLid dropping protectionMotor overheating protectionChamber overheating protection with ROTANTA 460R/460 RS centrifuges

High speed with angle rotors24,400 RCF with a max. capacity of 30 x 1.5/2.0 ml18,038 RCF with a max. capacity of 6 x 94 ml14,025 RCF with a max. capacity of 6 x 250 ml

High capacity with swing-out rotors4 x 750 ml at max. 4,779 RCF24 microtitre plates / 4 filter plates at max. 4,235 RCF or12 microtitre plates / 2 filter plates at max. 6,446 RCF120 blood collection tubes at max. 4,637 RCF

Performance

TechnologyAutomatic lid locking Frequency -controlled driveN control panel (can store up to 3 programmes)On option, extended S control panel (can store up to 89 programmes and features many additional functions)Temperature control in refrigerated models within a range of - 20°C to + 40°C ( with heating / cooling versions up to + 60°C )

Safety

3

ROTANTA 460 S benchtop centrifuge dimensions (H x W x D):453 x 554 x 707 mm

Cat.No. 5601

ROTANTA 460 R benchtop centrifuge, refrigerated dimensions (H x W x D):453 x 770 x 707 mm

Cat.No. 5605

4

Control Panels

The fully developed up to date Hettich control panels meetthe requirements of the users and are extremely easy to operate. Entry of the parameters is fast, precise, and convenientwith selector keys on the water-protected foil keypad.

The large display is well readable. During centrifugationthe actual values of the parameters are indicated.

The N Control Panel

The sophisticated S control panel is standard with the modelsROTANTA 460 S, ROTANTA 460 RS and ROTANTA 46 RSC.It enables programming with effortless ease. Whether entering single parameters or chaining complete program-mes, the clearly arranged display with its selector keys andadjusting knob provides extreme user- friendliness.

The S Control Panel

Speed RPM: Input in increments of 10.

Relative centrifugal force RCF: Input in increments of 1.

Radius r: Input in mm, when RPM or RCF need to be determined.

Time t: Input in minutes and seconds, max. 999 min, 59 sec.

Run-up/run-down times: Input of acceleration and brakingramps in levels 1 - 9, or time-controlled in minutes andseconds. 0 = unbraked run-down.

Deceleration with brake force cut -off: Input of the cut-offspeed in RPM.

Integral of the centrifugal acceleration provides continuousinformation on the accumulated RCF the centrifuged materialis exposed to during centrifugation.

Temperature T: Input in increments of 1°C within a range of - 20°C to + 40° C (ROTANTA 460 RS and ROTANTA 46 RSC).

Memory: Up to 89 complete programmes can be memorizedand recalled by their storing number. They remain in thememory even after the centrifuge has been switched off.

for special routine or scientific applications with centrifu-ges featuring the S control panel:

Data report system Detailed information on the Hettich data report system is presented in our brochure HETTINFO, which we will be happyto send you on request.

Chaining of programmes allows to programme the centrifugeto run different programmes in succession.

Second independent tacho system for calibrating the speedmeasuring instrument as required by quality managementsystems.

Key-operated switch for locking and protecting programmes.

Optional equipment

With ROTANTA 460, 460 R and 46 RC the N control panel is standard. It features the following functions:

Speed RPM: Input in increments of 10.

Relative centrifugal force RCF: Input in increments of 10.

Change-over RPM/RCF: By entering the rotor radius r/mm the centrifuge calculates and indicates speed or RCF.

Time t: Input in minutes and seconds, max. 99 minutes, 59 sec.

Temperature T: Input in increments of 1°C within a range of - 20°C to + 40° C (ROTANTA 460 R and ROTANTA 46 RC).

Run-up/run-down times: Input of acceleration and brakingramps in levels 1 - 9 or unbraked run-down. Level 9 alwaysrepresents the shortest possible run-up or run-down.

Impulse key: For short centrifuging operations. The rotorspins at the preselected speed or RCF as long as the key ispressed.

Memory: 3 complete running programmes can be storedand recalled. They remain in the memory even after the centrifuge has been switched off.

illustrated on rolling cabinet No.4615

ROTANTA 460 RS benchtop centrifuge, refrigerated dimensions (H x W x D):453 x 770 x 707 mm

Cat. No. 5606

Save space on the laboratorybench and gain more flexibilitywith trolleys and rolling cabinetsfor Hettich centrifuges.

All trolleys and cabinets are of sturdy design and feature largecastors and two locks. Any vibrations of the centrifuge are safely compensated.

765

260

580

810

550 550

765

190

190

260550

550

low and narrow,with one drawer

depth 650 mm

high and narrow,with two drawers

depth 650 mm

low and wide,with one drawer

depth 650 mm

high and wide,with two drawers

depth 650 mm

4612 Cat.-No.

low and narrow

depth 580 mm

4308Cat.-No. 4613 Cat.-No.

4614 Cat.-No.

low and wide

depth 580 mm

4318 Cat.-No. 4615 Cat.-No.

5

both rotors illustrated with buckets No. 5091 and transparent lids No. 5095

n= 4,600 min -1

RCF 4,779

1.5/2.0 ml 3 -100 ml 1.6 -10 ml 1.1-10 ml 15/50 ml

6-250 ml 15 /50 ml

1.5/2.0 ml 3 -250 ml 1.6-10 ml 1.1-10 ml 15/50 ml

n= 4,600 min -1

RCF 4,637

n= 4,600 min -1

RCF 4,235

rotor 4446, 6 -placen= 4,000 min -1

RCF 3,452

rotor 5694, 4 -placen= 4,000 min -1

RCF 2,916

Page8/9

Page9/10

12-50 ml 1-8 ml

12-50 ml 10- 94 ml

5091Cat No. 5095Cat No.

n= 4,600 min -1

RCF 4,779

Micro-titre Plate

MTP

MicronicSystem

MS

CulturePlateCP

DeepWell Plate

DWP

FilterPlateQP

90°90°

12 - 50 ml

n= 4,600 min -1

RCF 4,637

plus all tubes accommodated with

bucket No. 5091 in rotors No. 5694 and No. 4446 –

except 12 ml, 15 ml and 30 ml tubes with screw cap

1.5/2.0 ml 5-100 ml 1.6-10 ml 2.6-10 ml 15/50 ml 450 mltriple

450 mltriple

450 mlquadruple

10 ml 175-750ml

250-750 ml

1.5/2.0 ml 3 -250 ml 1.6-10 ml 1.1-10 ml 15/50 ml 12-50 ml 10- 94 ml

aerosol-tight

Page11

Page11

Page12

5625Cat No. 5627Cat No.

aerosol-tight

5620Cat No. 5621Cat No.

aerosol-tight

5623Cat No. 5621Cat No.

5691Cat No.

aerosol-tight

5628Cat No. 5629Cat No.

250 ml

Page13

Page14/15

rotor 4446, 6 -placen= 4,000 min -1

RCF 3,631

rotor 5694, 4 -placen= 4,000 min -1

RCF 3,095

Page12

Page15

aerosol-tight

Cat No.without buckets

5624

illustrated with buckets No. 5620 and transparent lids No. 5621

Swing-out rotor, 4 -place, n = 4,600 min -1

Rotors

Quick overview of rotors and suitable accessories.

The figures highlighted in the arrows refer to the pages where technical and ordering details are listed.

6

90°

5092Cat No. 5093Cat No.

Cat. No.without buckets

4446

Swing-out rotor, 6-place, n = 4,000 min -1

Cat. No.without buckets

5694

Swing-out rotor, 4 -place, n = 4,000 min -1

Swing-out rotor, 2 -place,ROTANTA 460 / 460 Sn = 5,900 min-1, RCF 5,858 rotor illustrated with buckets No.

4623, tightly sealed with lid No. 4627

90°

ROTANTA 460 R /460 RSROTANTA 46 RC/46 RSCn= 6,200 min-1, RCF 6,446

Micro-titre Plate

MTP

MicronicSystem

MS

CulturePlateCP

DeepWell Plate

DWP

FilterPlateQP aerosol-tight4620Cat. No.

Page16

Angle rotor, 30-place, n = 15,000 min-1, RCF 24,400

45°0.2-2.0 ml

aerosol-tight

4489Cat. No.

Page16

Angle rotor, 6 -place, n = 11,500 min-1, RCF 18,038

45°1.5/2.0 ml 15/25 ml 7.5 -10

ml15/50 ml 10- 94 ml

aerosol-tight

5615Cat. No.

Page17

Angle rotor, 6 -place, ROTANTA 460/460 Sn = 8,500 min-1, RCF 11,228

25°

ROTANTA 460 R/460 RSROTANTA 46 RC/46 RSCn= 9,500 min-1, RCF 14,025

15/25 ml 10- 94 ml 250 mlaerosol-tight

5645Cat. No.

Page18

Disc rotor, 6 -place,for Schlenk tubesn = 2,000 min-1, RCF 805

45°25/50 ml

5616Cat. No.

Page18

Swing-out rotor, 4 -place,for ASTM tubesn = 2,000 min-1, RCF 984

90°50/100ml 100 ml

4474Cat. No.

Page19

Disc rotor, 6 -place,for chrome bath tubesn = 2,000 min-1, RCF 917

90°30 ml

4619Cat. No.

Page19

autoclavable up to 134°C

autoclavable up to 134°C

autoclavable up to 134°C

7

Accessories

Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the

2078/0536

95 960

1.5 /2.0

90

4

11 x 38

156/196

3,691/4,637

224

4730

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

3 4 4 5 6 7

4,637

120 80

– – --- -- 0501 0578

4730 4730 4732 4732 4732 4732

10 x 60 10 x 88 12 x 60 12 x 75 12 x 82 12 x 100

5625

lidNo. 5627

Cat.-No.

aerosol-tight

196

2) 2)

1.6 - 5

80

13 x 75

4 - 7

13 x 100

4 - 7 8.5 - 10

68

16 x 75 16 x 100

95 960

1.1 - 1.4 2.7 - 3 2.6 - 2.9 4.5 - 5 4.9

90

4

120

4730

8 x 66 11 x 66 13 x 65capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

4 - 5.5 7.5 - 8.2 9 -10

196

4,637

80 68

4732 4732 4732 4732 4733 4733 4733

11 x 92 13 x 90 15 x 75 15 x 92 16 x 92

5625

lidNo. 5627

Cat.-No.

aerosol-tight

4732 4732 4733 4733

blood collection tubes blood collection/urine tubes

8

The frames for buckets No. 5625and 5620 are built in layers.For shorter tubes, 1 to 2 layersshould be removed.In the tables, the required layersare marked in grey.

196 191

4,637

8

100

44 x 100

85 100 250

12 4

38 x 106 40 x 115 65 x 115

2079

95 960

10

90

4

17 x 70

68

0544

4733 4733 4733

1216 x 102

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

15 25 50

196 191

4,637

24

0518 0519 0548

47354734

17 x 100 24 x 100 35 x 105

5625

lidNo. 5627

Cat.-No.

aerosol-tight

47374736 4736 4738

05260549 0523 0530

4,519 4,519

2) 2) 2) 2) 2)

braked run-down at level 9 unbraked run-down 1) Lowest attainable sample temperature in precooled refrigerated centrifuges at max. speed.

max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF.

9

2078/0536

95 960

1.5/2.0

90

4

192

4830 4830 4830

11 x 38

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

3 4 4 5 6 7

156/196 196

3,691/4,637 4,637

96 76

-- -- -- -- 0501 0578

4832 4832 4832 4832

10 x 60 10 x 88 12 x 60 12 x 75 12 x 82 12 x 100

5620

lidNo. 5621

Cat.-No.

aerosol-tight

* The screw cap for tube No. 0538is available with Cat.No. 0539(dimensions with lid 38 x 106 mm).

Swing-out rotor, 4 -place, No.5624,illustrated with buckets No.5620, transparent lids No.5621 and frame No. 4833 for 19 tubes.

n = 4,600 min-1

3) When using these tubes, the inserts need to betaken out of the frames.

2079

95 960

10

90

4

76

4833 4833

17 x 70

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

15 25 50

196

4,637

1628

0518 0519 0548

48354834

17 x 100 24 x 100 35 x 105

5620

lidNo. 5621

Cat.-No.

aerosol-tight

8

0526

4837

100

44 x 100

85 100 250

196191

4,6374,519

191

4,519

12 4

0549 0523 0530

4836 4836 4838

38 x 106 40 x 115 65 x 115

2) 2)

2) 2) 2) 2) 2)

0509

95 960

15

90

4

48

4739

17 x 120

20

0513

50

29 x 115

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

12 25 / 30

196

4,637

48 24

-- --

4739 4734

17 x 100 25 x 90/110

4740

5625

lidNo. 5627

Cat.-No.

aerosol-tight

10 30 50 85

68

4733

16 x 80 26 x 95

94

191

4,519

24 20 12

-- 0545 0546 0547 0538*

4734 4740 4736 4736

29 x 107 38 x 106 38 x 102

50

20

--

4740

29 x 115

3) 3) 3)

braked run-down at level 9 unbraked run-down 1) Lowest attainable sample temperature in precooled refrigerated centrifuges at max. speed.

Accessories

Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the

95 960

1.1 - 1.4 2.7 - 3 2.6 - 2.9 4.5 - 5 4.9

90

4

96

4830

8 x 66 11 x 66 13 x 65capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

4 - 5.5 7.5 - 8.2 9 - 10

196

4,637

76

blood collection tubes

4832 4832 4832 4832 4833 4833 4833

11 x 92 13 x 90 15 x 75 15 x 92 16 x 92

5620

lidNo. 5621

Cat.-No.

aerosol-tight

95 960

10 30 50 85

90

4

76

4833

16 x 80 26 x 95

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

94

196 191

4,637 4,519

28 20 12

-- 0545 0546 0547 0538*

4834 4840 4836 4836

29 x 107 38 x 106 38 x 102

5620

lidNo.5621

Cat.-No.

aerosol-tight

250

62 x 122

4

5127 -- 4457 0510 0512

4841 4842 4843 4844 4845

400

81 x 136

450 580 750

202

4,779

70 x 160 87 x 147 97 x 152

4)

95 960

1 - 5

90

4

4832

13 x 75

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

dimensions Ø x L mm

4 - 7 4 - 7 8 8 - 10

196

4,637

76

4832 4833 4833 4833

13 x 100 16 x 75 16 x 125 16 x 100

5620

lidNo.5621

Cat.-No.

aerosol-tight

15

56

4839

17 x 120

20

50

29 x 115

12 25/30 50

56 28 20

4839 4834 4840

17 x 100 25x90/110 29 x 115

4840

blood collection/urine tubesCat.-No. 0509 0513 -- -- --

3) 3) 3)

10

4)

*The screw cap for tube No. 0538 is available with Cat. No. 0539(dimensions with lid 38 x106 mm).

3) When using these tubes,the inserts need to betaken out of the frames.

4) When using these tubes, bucket No. 5620 cannot be closed with lid No. 5621.

braked run-down at level 9 unbraked run-down 1) Lowest attainable sample temperature in precooled refrigerated centrifuges at max. speed.

max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF.

95 960

90

4

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

dimensions Ø x L mm

1.6 - 5 4 - 7 8.5 - 10 10

197 201 214188189

4,7554,6604,4474,471 5,063

84 76 76

4435 4435 4436 4434

13 x 75 13 x 100 16 x 100 16 x 80

5623

lidNo.5621

Cat.-No.

aerosol-tight

15

48

4437

17 x 120

20

50

29 x 115

175 175 200

4

4440 4430 4430

61 x 118 62 x 144 60 x 130

4441

Cat.-No. 0509- 0513 Falcon Nalgene Nunc

95 960

1.5/2.0

90

4

168

4432

11 x 38

120

4433

5

12 x 75

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

dimensions Ø x L mm

7 15 25 50

187192188189192 186 189

4,424 4,4004,5424,4474,4714,542

120 2876

4433 4436 4438 4439

12 x 100 17 x 100 24 x 100 34 x 100

5623

lidNo.5621

Cat.-No.

aerosol-tight

100

816

4442

44 x 100

84

2.6 - 2.9

13 x 65

2.7 - 3 4.5 - 5 4.9

120 120 84

4433 4433 4435

11 x 66 11 x 92 13 x 90

4435

11

05260521051905180578-2078/0536Cat.-No.

blood collection/urine tubes

4,471

4 - 5.5

76

4434

15 x 75

76

4434

9 - 10

16 x 92

197

4,660

blood collection tubes

2) 2) 2) 2) 2)

1) Lowest attainable sample temperature in precooled refrigerated centrifuges at max. speed.

4) When using these tubes, bucket No. 5623 cannot be closed with lid No. 5621.

5) without filter

6) Lowest attainable sample temperaturein refrigerated centrifuges at max. speed.

braked run-down at level 9

unbraked run-down

Falcon

95 960

225

90

4

4 4 4 4 4

4440 4430 4449

61 x 137

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

250 500 250 450 750 450

214 206 214 206 214

4,873 5,063 4,873 5,063

Corning Corning 5127 4457 0512 blood bagsystem

4443 4453 4451 -

60 x 172 96 x 147 62 x 122 70 x 160 97 x 152 triple

5623

lidNo.5621

Cat.-No.

aerosol-tight

5,063

4) 4) 5) 5693

95 960

450 450

90

11

4 4

5692 5692

triple

capacity ml

run-up in sec

run-down in sec

temperature °C 6)

radius in mm

RCF

systems per rotor

Cat.-No.

Cat.-No.

blood bag system

196

5695

quadruple

without filterholder for systems

5691Cat.-No.

4,637

with or without filter

Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the

Accessories

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

plates per rotor

Cat.-No.

dimensions: D x W x H *

5628

lidNo. 5629

Cat.-No.

aerosol-tight

*max. adaptable size (D x W x H)86 x 128 x 85 mm

plates

95 960

90

4

86x128 x 83 86x128x44.5 86 x128 x 46 86 x128 x 22 86x128 x17.5 86 x128 x15

4

179

4,235

16 20 24

QP DWP MS CP MTP

4626

12

1) Lowest attainable sample temperature in precooled refrigerated centrifuges at max. speed.7) With the exception of adapter No. 5269, two of these adapters need to be placed into bucket No. 5628.

# With Cat.No. 5247-91 or 5248-91 these adapters can be ordered with a decanting aid.

6 7 15 25 50

12 x 82 12 x 100 17 x 100 24 x 100 34 x 100

100 100

40 x 115 44 x 100

90

173 172 177

4,116

160 160 96 40 16 8 8

95 960

4

2078/0536

1.5 / 2.0 1.5 / 2.0

128

5281

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

4,164 3,004/4,164

176 127/176 172 174

320

5257

3

160

5267

10 x 60

––

4,069

4

5227 5247 5248 5242 5243 5249 5262

4,0694,093

0501 0578 0518 0519 0521 0523 0526 0509 0513

# #

11 x 38 11 x 38

180

4,1874,258

--

505015

162456

524352696306

29 x 11529 x 11517 x 120

7)

5628Cat.-No.

without lid No. 5629

No. 5220

2) 2) 2) 2) 2) 2) 2)

+2 x 6316

96

5268

1.6 - 5

13 x 75

4 - 74 - 7 8.5 - 10

116/172

4,093 2,744/4,0694,116

96 9696 16

63015264 5248 5280

13 x 10016 x 75 16 x 100

173174176

4,164

capacity ml

173

4,093

Cat.-No.

Cat.-No.

dimensions Ø x L mm

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

95 960

90

9 - 107.5 - 8.24.5 - 54 - 5.52.7 - 31.1 - 1.4

889696160160 160

525852475227 52645267 5248

16 x 9215 x 9211 x 9215 x 7511 x 668 x 66

4,069

172

4

4,093

173

4,116 4,116

174 174

2.6 - 2.9

5268

13 x 654.9

5268

13 x 90

176 176

4,164 4,164

96 96

blood collection tubes blood collection/urine tubes

5628Cat.-No.

50

176

4,164

16

0513

5259

29 x 115

two-tierframe

for cytoprepara-

tions

Pleaseask for our

detailedcyto

brochure!

7)

without lid No. 5629

No. 5220

only 1 x

Swing out - rotor, 4 -place, No. 5624illustrated with buckets No. 5628, transparent lids No. 5629 and plate removal frame No. 4626.

n = 4,600 min -1

max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF.

34 265

32

155 158 155 158 155 156 155 163 159

2,773 2,826 2,773 2,826 2,773 2,791 2,773 2,916 2,844

80 48 48 48 48 48 48 28 8

5247 52685268 5248

blood collection tubes blood collection /urine tubes

4.5 - 5 4.9

11 x 92 13 x 90

7.5 - 8.2

15 x 92

155

2,773

44

5258

9 - 10

16 x 92

6301 5264 5248 6306 5259

0509 0513

1.6 - 5 4 - 7 4 - 7 8.5 - 10

13 x 75 13 x 100 16 x 75 16 x 100

15 50

17 x 120 29 x 115

4) 4) 4) 4)

-3

--

12

163

2,916

28

6306

17 x 100

155

2,773

--

50

8

5243

29 x 115

+2 x 6316

Swing out - rotor, 4 -place, No.5694, illustrated with buckets No.5091and tranparent lids No. 5095.

n = 4,000 min -1

--

30

154

2,755

20

5266

25 x 110

With Cat.No. 5247-91 or 5248-91 these adapters can be ordered with a decanting aid. #

97/153

1,735/2,737

8

two-tierframe

for cytoprepara-

tions

Pleaseask for our

detailedcyto

brochure!

34 265

6 7 15 25 50

32

146110/159 156 155 154

2,6121,968/2,844 2,791 2,773 2,755

64160 80 80 48 20 8 4

0501 0578 0518 0519 0521 05260523

52815257 5227 5247 5248 5242 5243 5249 5262

12 x 82 12 x 100 17 x 100 24 x 100 34 x 100

100

44 x 100

100

40 x 115

capacity ml

run-up in sec

run-down in sec

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

1.5/2.0 1.5/2.0

11 x 38 11 x 38

temperature °C 1) 3

5091Cat.-No.

lid No. 5095

capacity ml

run-up in sec

run-down in sec

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

temperature °C 1)

5091Cat.-No.

lid No. 5095

# #

5280

156154 158 156

2,7912,755 2,826 2,791

8080 48 48

52275267 5268 5264

blood collection tubes

2.7 - 31.1 - 1.4 2.6 - 2.9 4 - 5.5

11 x 668.5 x 66 13 x 65 15 x 75

13

2078/0536-

braked run-down at level 9 unbraked run-down 1) Lowest attainable sample temperature in precooled refrigerated centrifuges at max. speed.4) When using these tubes, bucket No. 5091 cannot be closed with lid No. 5095.

Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the

Accessories

14

Swing out - rotor, 6 -place, No. 4446, illustrated with buckets No. 5091 and tranparent lids No. 5095.

n = 4,000 min -1

6 7 15 25 50

12 x 82 12 x 100 17 x 100 24 x 100 34 x 100

100 100

40 x 115 44 x 100

45

186 185 184

3,327 3,309

184 185

3,291 3,309

120 120 72 30 12 6

55 551

4

2078/0536

1.5 / 2.0 1.5 / 2.0

96

5281

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

3,148 2,504 /3,381

176 140 /189

240

5257

3

120

5267

10 x 60

––

3,291

184

5091Cat.-No.

lidNo. 5095

0

5227 5247 5248 5242 5243 5249 5262

30

5266

3,291

0501 0578 0518 0519 0521 0523 0526

# #

--

12

188

3,363

42

6306

--

30

25 x 11017 x 100

--

50

12

5243

29 x 11511 x 38 11 x 38

4) 4)

+ 2 x 6316

run-down in sec

0501 0518 0519 0509

34 265

6

32

48

5128

12 x 82

5092

lidNo. 5093

aerosol-tight

28

5121

15

17 x 100

capacity ml

run-up in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

Cat.-No.

25 1550 100 100 250250

173166

2,898 3,095 3,0052,969

16 284

0521 0526 0523 51270530

5122 51295125 5126 631910575124

24 x 100 17 x 12034 x 100 44 x 100 40 x 115 62 x 12265 x 115

0578

7

48

5120

12 x 100

3,005

168 162 165 173

-3

2,952 3,095

4 4

0513

50

8

5123

29 x 115

--

12

168 158

2,826

28

5121

17x 100

--

25

12

5134

25 x 90

--

30

156 169

2,791 3,023

16

5122

25 x 110

--

50

8

5135

29 x 115

1) Lowest attainable sample temperature in precooled refrigerated centrifuges at max. speed.4) When using these tubes, bucket No. 5091 cannot be closed with lid No. 5095.# With Cat.No. 5247-91 or 5248-91 these adapters can be ordered with a decanting aid.

max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF.

15

0501 0518 0519 0509

55 551

6

45

72

5128

12 x 82

5092

lidNo. 5093

aerosol-tight

42

5121

15

17 x 100

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

Cat.-No.

25 1550 100 100 250250

203196

3,434 3,6313,506

24 426

0521 0526 0523 51270530

5122 51295125 5126 631910575124

24 x 100 17 x 12034 x 100 44 x 100 40 x 115 62 x 12265 x 115

0578

7

72

5120

12 x 100

3,542

198 192 195 203

0

3,488 3,631

6 6

0513

50

12

5123

29 x 115

--

12

198 188

3,542 3,363

42

5121

17x 100

--

25

18

5134

25 x 90

--

30

186 199

3,327 3,560

24

5122

25 x 110

--

50

12

5135

29 x 115

72

5268

1.6 - 5

13 x 75

4 - 74 - 7 8.5 - 10 15 50

193 189

3,309 3,452 3,3813,327

7272 1242

0509 0513

63015264 5248 52596306

13 x 10016 x 75 16 x 100 17 x 120 29 x 115

185186

5280

188 128/184

3,363 2,290/3,291

12

two-tierframe

for cytoprepara-

tions

Pleaseask for our

detailedcyto

brochure!

capacity ml

185

3,309

Cat.-No.

Cat.-No.

dimensions Ø x L mm

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

55 551

45

9 - 107.5 - 8.24.5 - 54 - 5.52.7 - 31.1 - 1.4

667272120120 120

525852475227 52645267 5248

16 x 9215 x 9211 x 9215 x 7511 x 668 x 66

3,291

184

0

3,309

185

3,327 3,327

186 186

2.6 - 2.9

5268

13 x 65

4.9

5268

13 x 90

188 188

3,363 3,363

72 72

blood collection tubes blood collection/urine tubes

5091Cat.-No.

lidNo. 5095

4) 4)

braked run-down at level 9

unbraked run-down

1) Lowest attainable sample temperature in precooled refrigerated centrifuges at max. speed.4) When using these tubes, bucket No. 5091 cannot be closed with lid No. 5095.

Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the

Accessories

16

48 600

max. 150

55 / 50

10

86x128 x 83 86x128x44.5 86 x128 x 46 86 x128 x 22 86x128 x17.5 86 x128 x15

2

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF ROTANTA 460 R

RCF ROTANTA 460

plates per rotor

Cat.-No.

plates

dimensions: D x W x H *

53 600

5,858

6,446

8 10 12

QP DWP MS CP MTP

4626

4623

lidNo.4627

Cat.-No.

braked run-down at level 9 unbraked run-down

1) Lowest attainable sample temperature in precooled refrigerated centrifuges at max. speed.

-- -- -- -- 2078 0536

77 240

0.2

73

6 x 18

4489

0.4

6 x 45capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

Cat.-No.

0.5 0.8 1.5 2.0

8 x 30 8 x 45 11 x 38 11 x 38

7

2024 2023 --

24,400

97

For centrifu-gation at

high speedswe recom-

mend to use adapter

No. 2031

aerosol-tight

30

Angle rotor, 30 -place, No.4489n = 15,000 min-1

*max.adaptable size (D x W x H) 86 x 128 x 85 mm

Swing-out rotor, 2 -place, No. 4620,illustrated with buckets No. 4623, transparent lids No. 4627 and plate removal frame No. 4626.

n = 5,900 min -1 / 6,200 min -1

max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF.

17

Angle rotor, 6 -place, No.5615n = 11,500 min-1

68 641

66

5615

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

Cat.-No.

11711217,29916,560

126 66 6

--0518 05090519 0545 0546 05130538*0547

14481451 14661446 1454--

117 119122

4

17,299 17,59518,038

6 66

blood collection tubes

1447 1447 1451

6

115115 112 115

17,00317,003 16,560 17,003

2078/0536

1449

24

117

17,299

aerosol-tight

2) 2)

1) Lowest attainable sample temperature in precooled refrigerated centrifuges at max. speed.* The screw cap for tube No. 0538 is available with Cat. No. 0539 (dimensions with lid 38 x 106 mm)

9 - 10 7.5 - 8.21015 1525 30 50 5085 941.5/2.0

15 x 92 16 x 9216 x 8017 x 100 17 x 12024 x 100 26 x 95 29 x 107 29 x 11538 x 106 38x10211 x 38

Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the

Accessories

Disc rotor, 6 -place,

No.5616for Schlenk tubesn = 2,000 min-1

21 286

25

17

- 14

6

24x146.5

6

0532 0533

4317 --

5038x148.5

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

175 180

783 805

5616Cat.-No.

* The screw cap for tube No. 0538 is available with Cat. No. 0539 (dimensions with lid 38 x 106 mm)

Angle rotor, 6 -place,

No.5645n = 8,500 min-1 / 9,500 min-1

98/115

105/120 1,110/1,103

5645

dimensions Ø x L mm

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF ROTANTA 460

RCF ROTANTA 460 R

tubes per rotor

Cat.-No.

Cat.-No.

capacity ml

Cat.-No.

302515 10 50 85 94 250

4842 18 18

--0518 0519 05460545 51270538*0547

56415646 5643 5644 5644 --

16 x 8017 x 100 24 x 100 26 x 95 38 x 10629 x 107 62 x12238 x102

4

6 6 6 6

5642 5642

132 128 133 128 120 122 139

13,319 12,915 13,420 12,915 12,108 12,310 14,025

10,662

aerosol-tight

10,339 10,743 10,339 9,693 9,855 11,228

2) 2)

1) Lowest attainable sample temperature in precooledrefrigerated centrifuges at max. speed.

18

Disc rotor, 6 -place,

No. 4619for chrome bath tubesn = 2,000 min-1

Swing-out rotor, 4-place, No. 4474for ASTM tubes n= 2,000 min-1

17

21/286

- 11

205

917

6

chromebath tube

30

4619

capacity ml

run-up in sec

run-d.insec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No. 0529

Cat.-No.

8) The max. permissible RCF for ASTM tubes is 700.

50 100 100 100

45

- 8

55 551

220 216

984 966

4 4

– 0528 – 0531

4278 0771 4277 4276

45 x130 58 x161 44 x168 37 x 200

4275

capacity ml

run-up in sec

run-down in sec

temperature °C 1)

radius in mm

RCF

tubes per rotor

Cat.-No.

Cat.-No.

dimensions Ø x L mm

Cat.-No.Cat.-No.

8) 8) 8) 8)

braked run-down at level 9

unbraked run-down

1) Lowest attainable sample temperature in precooled refrigerated centrifuges at max. speed.

max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF. 2) For glass tubes the max. RCF is 4,000. · Please take care not to exceed the tubes’ max. permissible RCF.

19

ROTANTA 460

208 - 240 V 1 ~

50 - 60 Hz

1.5 kVA

EN 55011 ISM class B

EN 50082 -1 --

110-127 V 1~

50 - 60 Hz

1.3 kVA

FCC class A

208 - 240 V 1 ~

50 - 60 Hz

2.4 kVA

EN 55011 ISM class B

EN 50082 -1 --

110-127 V 1~

60 Hz

2.0 kVA

FCC class A

ROTANTA 460Benchtop centrifuge, without rotorCat.No. 5600 Cat.No. 5600-01

ROTANTA 460 RBenchtop centrifuge, refrigerated, without rotorCat.No. 5605 Cat.No. 5605-01

ROTANTA 460 SBenchtop centrifuge, without rotorCat.No. 5601 Cat.No. 5601-01

ROTANTA 460 RSBenchtop centrifuge, refrigerated, without rotorCat.No. 5606 Cat.No. 5606-01

ROTANTA 46 RSC **Underbench centrifuge, refrigerated, without rotorCat.No. 4813 Cat.No. 4813-01

ROTANTA 46 RC**Underbench centrifuge, refrigerated, without rotorCat.No. 4812 Cat.No. 4812-01

Capacity:

Speed/RCF:

Centrifuging chambertemperature:

Running time:

*Power supply:

Frequency:

Consumption:

Radio interference:

Immunity:

controllable from -20°C to +40°C(with heating / cooling models -20°C to +60°C )

Technical Details

4 x 750 ml, swing - out rotor

n= 15,000 min-1 / RCF 24,400

4 x 750 ml, swing - out rotor

n= 15,000 min-1 / RCF 24,400

1-99 min. resp.1-999 min. (”S“),∞ (continuous run), impulse key

(short cycle mode)

1-99 min. resp.1-999 min. (”S“),∞ (continuous run), impulse key

(short cycle mode)

453 x 554 x 707 mm

approx. 106 kg approx. 115 kg

Dimensions (H x W x D):

Weight:

453 x 770 x 707 mm ROTANTA 460 R/RS630 x 580 x 685 mm ROTANTA 46 RC/RSC

approx. 147 kg = 5605, 5606approx. 156 kg = 5605-01, 5606-01approx. 113 kg = 4812, 4813approx. 119 kg = 4812-01, 4813-01

_

*other voltages on request **power supply, frequency and consumption values of ROTANTA 46 RC and 46 RSC centrifuges on request

Andreas Hettich GmbH & Co. KGGartenstr. 100 · D-78532 TuttlingenPhone +49 (0) 74 61/7 05 - 0Fax +49 (0) 74 61/ 7 05 - 1 22

www.hettichlab.com · [email protected] · [email protected]

5600.0305 td GB © by Hettich Tuttlingen · Printed in Germany · Design, form and colour modifications reserved.

National Sales +49 (0) 74 61 /7 05 - 2 00National Service +49 (0) 74 61/7 05 - 2 02Internat. Sales +49 (0) 74 61/7 05 - 2 01Internat. Service +49 (0) 74 61/7 05 - 2 03