32
Happy HCS 1201-30 Voyager For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 1 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc. Bernina’s Happy HCS 1201-30 Voyager Service Manual The information contained in this Manual is designed to assist in operating, troubleshooting, and servicing the Happy HCS 1201-30 Voyager. The information given is not to replace, but to accompany the original Happy HCS 1201-30 Voyager User/Operation/Service manuals. Strict ESD guidelines given by the manufacturer MUST be adhered to when servicing the machines and handling the circuit boards.

Berninas-Happy-Service-Manual_166b7.pdf

Embed Size (px)

Citation preview

Page 1: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 1 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Bernina’s Happy HCS 1201-30 Voyager Service Manual

The information contained in this Manual is designed to assist in operating, troubleshooting, and servicing the Happy HCS 1201-30 Voyager. The information given is not to replace, but to accompany the original Happy HCS 1201-30 Voyager User/Operation/Service manuals. Strict ESD guidelines given by the manufacturer MUST be adhered to when servicing the machines and handling the circuit boards.

Page 2: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 2 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Needle Position (Left/Right)

With machine on, bring pressure foot down. (P.FOOT key on control box.) Bring needle #6 down.

The needle should be in the center of the stitch hole. Note: Due to shipping and rough handling the entire head can be displaced.

Page 3: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 3 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Needle Position (Left/Right)

Loosen three screws of unit assembly.

Turn upper shaft to set near to [0 degrees-L point].

Align so that needle is centered left/right in stitch plate.

Page 4: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 4 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Push the unit assembly to the front of the machine.

Needle Position (Left/Right)

Retighten three screws. After performing adjustment, check hook/needle clearance.

Page 5: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 5 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Needle Position (Front/Back)

Needle should be centered in the needle plate. Note: Due to shipping and rough handling the head can be displaced.

With machine on, bring pressure foot down. (P.FOOT key on control box.) Bring needle #6 down.

Turn upper shaft to set near to [0 degrees-L point].

Page 6: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 6 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Needle Position (Front/Back)

Unplug and remove light, loosen two screws, move head unit so that needle is in the center of the stitch hole, retighten the two screws. Check and adjust with 1st, 6th and 12th needles. After performing adjustment, check hook/needle clearance.

Page 7: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 7 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Hook/Needle Timing and Clearance

Remove needle plate.

Bring needle #6 down.

With machine on, bring pressure foot down. (P.FOOT key on control box.)

Page 8: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 8 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Hook/Needle Timing and Clearance

Front view Hook Timing When the upper shaft is at [23 degrees], the hook tip should be flush with the left side of the needle.

Hook Clearance When the upper shaft is at [23 degrees], the hook needle clearance should be from [0.1 to .15 mm].

Page 9: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 9 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Hook/Needle Timing and Clearance

Turn upper shaft to set near to [23 degrees].

Loosen three screws on collar. Attain correct hook /needle timing and clearance, retighten screws. (Check with 1st, 6th, and 12th needles.)

Page 10: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 10 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Bobbin Case Retainer (Bobbin stopper)

Bobbin case retainer must be centered in bobbin case basket cutout and center to the needle. The distance from stopper to bobbin case is [0.8mm].

Needle

Basket

Retainer stopper

Page 11: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 11 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Bobbin Case Retainer (Bobbin stopper)

Loosen the screws to the extent that retainer on bobbin case holder is able to move.

Adjust bobbin case retainer to attain correct position.

0.8mm feeler gauge

Page 12: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 12 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Needle Height

Remove lower front panel. (Two Phillips screws and the take up lever cover clip, two screws.) Remove bobbin case. With machine on, bring pressure foot down. (P.FOOT key on control box.) Bring needle down.

When upper shaft is at [60 degrees], the needle tip must be flush with the tubular needle plate. Remember there are 12 needles that must be checked and adjusted individually.

Page 13: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 13 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Needle Height

Remove the lower front panel (Tip: pull 1foot of thread each needle and knot them together.) Loosen needle bar boss and adjust the needle height

Turn upper shaft to set dial disk to [60 degrees], at this point the needle tip must be flush with the standard needle plate.

Check that the needle holder does not touch the needle guard.

Page 14: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 14 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Needle Height

After setting the needle height, check the distance between needle bar boss and boss B. It must be exactly [25.1mm]. (Measure with a caliper.) Adjust boss B accordingly. Check that the movement of the needle bar moves smoothly. Remember there are 12 needles that must be checked and adjusted individually.

Boss B

Page 15: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 15 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Height of Pressure Foot

Between the pressure foot and the standard needle plate, the distance is [1.2mm]. The foot should be centered with respect to the needle hole in the needle plate. Note: Check if the presser foot is not bent and the foot is in line with the needle before making any adjustments.

Note: There are two separate needle plates [cap needle plate and tubular (standard) plate]. Using either one, the pressure foot position has to be selected accordingly. Tubular position lower, cap position upper.

Page 16: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 16 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Height of Pressure Foot

- Move to needle position #1 - Lower the pressure foot - Pull needle bar down - Rotate hand wheel to [0 degrees] - Loosen the screw of the guide bar block - The distance between the foot and the standard needle plate must be [1.2mm] and the foot centered on the needle hole - Retighten the guide bar block screw

Page 17: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 17 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Thread Holder Remove the lower front panel (Tip: pull 1foot of thread each needle and knot them together.) Measure the distance of 48.4mm (+/-0.1mm) between lower part of moving head and holder. Loosen the screw on each side and move the thread holder. Prior to tightening, pull the bar toward the front.

Page 18: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 18 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Thread Holder

Lower the pressure foot and manually move the hook in and out to check if the hook moves smoothly and that that the hook is 1.2mm above the needle. Check with 1st, 6th and 12th needles. (Positional relationship between hook and holder (lower).) Before making any adjustments, make sure the catcher hook is not bent. Adjust height of thread catcher device by loosening two Philips screws and moving the mechanism.

1.2 mm

Page 19: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 19 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Bobbin Thread Holder

Remove needle plate. Open the moving knife and place a piece of thread in the knife’s cutting path. Close the knife to cut the thread. The upper part of the thread is cut and the lower part of the thread is held by the pressure plate.

Page 20: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 20 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Bobbin Thread Holder

Pull bobbin thread toward arrow mark and see that bobbin thread comes off with the pull gauge approximately [20-25gr]. Loosen locknut and adjust pressure plate. Tighten lock nut. (Note: The end of the pressure plate must be parallel with the stationary knife.)

Page 21: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 21 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Thread Cutter Timing (Moving Knife)

Thread cutter timing: Move upper shaft dial disk to [90 degrees], pull down and hold the lever (1), rotate the hand wheel disk until a defined stop can be felt. At this point the disk should be at [116 degrees].

Remove the power supply.

1

1

Page 22: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 22 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Thread Cutter Timing (Moving Knife)

Loosen the set screw on the aluminum collar. Set dial disc to [116 degrees], turn thread cutting cam clockwise while pushing release lever down until as stop can be felt. Push the black cam to the left against the collar to eliminate any play between cam and collar. Then tighten the screw. Recheck the adjustment.

Collar

Page 23: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 23 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Adjusting Moving and Fixed Knife

Remove needle plate. Check if knife drive shaft has no play up and down. If play is found, adjust by moving the collar (1) on the bottom of the shaft.

1

Page 24: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 24 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Adjusting Moving and Fixed Knife

Check the pitch of the fixed knife by checking the cutting action using two polyester threads. Adjust by loosening the locknut and moving the knife with the set screw. Adjust slant of fixed knife with upper adjustment screws.

Page 25: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 25 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Adjusting Position of Moving Knife

Loosen screw on link pin. Turn link pin to adjust position of moving knife.

A has to clear B

D

A

B C

C

In the rest position, the end of the moving knife has to be flush with the edge of the stationary knife (point D).

Page 26: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 26 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Adjusting Position of Moving Knife

Adjust the fixed knife for the edge A to clear the edge of B. Adjustment is done with screws C.

A has to clear B

D

A

B C

C

Page 27: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 27 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Adjusting Position of Keeper

Push the keeper toward the bobbin. The tip of the keeper should be 1mm away or just slightly touching the bobbin. Adjust by moving the keeper base.

1mm

Page 28: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 28 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

2 mm

Adjusting Position of Keeper

With the Keeper/solenoid activated, check that there is [2.0mm] clearance between solenoid bracket and slider.

Page 29: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 29 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Adjusting Position of Keeper

To adjust, loosen screw on solenoid base. Adjust to attain a [2.0mm] clearance between solenoid bracket and slider.

Page 30: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 30 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

20 gr.

Checking and Adjusting the Bobbin Tension

Check the bobbin tension by holding the thread and letting the bobbin drop, the bobbin should drop down slowly. (Equivalent to 20gr.) Adjust by turning screw on bobbin.

Page 31: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 31 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Basic Tension Settings

Checking and Adjusting the Upper Thread Tension

Using a calipers check the distances between the center posts and the front of the tension dials. The distance for the upper tension dials should be approximately 3.0mm and for the lower dials approximately 4.0mm.

Page 32: Berninas-Happy-Service-Manual_166b7.pdf

Happy HCS 1201-30 Voyager

For the use of authorized BERNINA dealers only Last Revised 3/8/2007 Page 32 of 32 Happy HCS-1201 Voyager handouts ©2007 Bernina of America Inc.

Final Tension Settings

Checking and Adjusting the Upper Thread Tension

To check tensions, use the design called “Tension Test Design Htest12.dst”. Sew out the design and check the sample. Adjust tension dials (Lower first, then upper) to attain a sample were the top thread showing on the bottom is minimal. (1/3 of top thread visible, 2/3 of bottom thread visible) The test design is posted on the extranet.