21
BEST 70P Cyclotron beam commissioning at LN Legnaro © Best Theratronics Ltd Vladimir Ryjkov, Best Cyclotron Systems Inc.

BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

BEST 70P Cyclotron beam commissioning at LN Legnaro

© Best Theratronics Ltd

Vladimir Ryjkov,

Best Cyclotron Systems Inc.

Page 2: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Best Cyclotron

• Best Cyclotron Systems Inc – one of several companies worldwide offering cyclotrons for commercial medical isotope production.

• Line of cyclotrons includes 15MeV, 25MeV, 35MeV and 70MeV H- cyclotrons.

© Best Theratronics Ltd

Page 3: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Commercial cyclotrons in nuclear science

• 70MeV H- cyclotrons are also great option for online rare isotope production by fission in Uranium targets.

• Cost effective and power efficient.

© Best Theratronics Ltd

Page 4: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Best 70P in LN Legnaro

• Best 70P cyclotron selected for Italian Istituto Nazionale di Fisica Nucleare (INFN) LaboratoriNazionali di Legnaro (LN Legnaro).

• Best 70P was also selected for RISP project underway here in Daejeon, South Korea.

© Best Theratronics Ltd

Page 5: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

LN Legnarofacility

© Best Theratronics Ltd

ISOL1 ISOL2

Med. isotope

research

Med. isotope

production

Neutron

studies

Page 6: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Best Cyclotron Delivery

© Best Theratronics Ltd

Page 7: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Beam dump (provided by LN Legnaro)

• Located in ISOL1 cave.

• 50kW capacity

• Locally shielded

© Best Theratronics Ltd

from INFN annual report (2015)

Page 8: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

© Best Theratronics Ltd

Best Cyclotron Delivery

Page 9: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

© Best Theratronics Ltd

Best Cyclotron Delivery

Page 10: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Best 70P cyclotron specifications

• H- accelerator

• Variable energy 35MeV to 70MeV protons.

• Up to 700uA beam (49kW beam power).

• Two extraction ports, each with up to full current capability.

© Best Theratronics Ltd

Page 11: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

First step

• Accelerate a few turns to a beam stop “pop-up probe” located <1MeV.

• Ensured we have enough to extract full power (700uA)

© Best Theratronics Ltd

Page 12: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

First high power run

© Best Theratronics Ltd

• Gradually increasing intensity up until 500uA

• Vacuum at the beam dump deteriorated and test stopped

• Operation above 200uA caused beam dump vacuum condition to permanently worsen.

Page 13: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Dual extraction

© Best Theratronics Ltd

• Had to limit amount of beam extracted on port #2.

• Excludes more common and easier 1:1 or 1:5 intensity ratios.

• Shown is a test with 1:20 beam intensity ratio.

Page 14: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Endurance test

• 200uA, 40MeV

• Initially planned – 5 days

• Extended by mutual agreement due to irrelevant operation stoppages (4 building safety systems false positives, connector corrosion)

© Best Theratronics Ltd

Page 15: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Endurance test

© Best Theratronics Ltd

Page 16: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Endurance test vacuum trend• Important

(H- stripping)

• Ultimate vacuum level of ~2x10-8

Torr

• Operational (beam ON): ~4x10-8 Torr

© Best Theratronics Ltd

Page 17: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Endurance test tuning• Injection line and beamline settings kept untouched

• Extractor tuning to compensate for foil deformation due to heat

• Main magnet tuning to compensate for thermal drift in PS

• Operated in very low collimator current mode (<1%), with fairly flat response, so most tuning was exploratory.

© Best Theratronics Ltd

Page 18: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Endurance test MM tuning• 30mA (0.05%)

change over 10 days.

© Best Theratronics Ltd

Page 19: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Endurance test extractor tuning• 2 foil changes

© Best Theratronics Ltd

Page 20: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Outlook

• Training of LN Legnaro personnel is complete.

• Operation up to 500uA in the last few month, constrained by radiation protection. Further increase planned.

• Cyclotron for RAON project is under construction.

© Best Theratronics Ltd

Page 21: BEST 70P Cyclotron beam commissioning at LN Legnaro · 2018-03-05 · Endurance test tuning •Injection line and beamline settings kept untouched •Extractor tuning to compensate

Thank you

© Best Theratronics Ltd