Upload
adamvh
View
214
Download
0
Embed Size (px)
Citation preview
8/2/2019 Best Tuning Practices for Power Vault MD3600 Series Storage Arrays
1/8
MD3600i Series ArrayBest Tuning Pract ices
A Dell Technical Whit e Paper
Dell PowerVaultSeries
8/2/2019 Best Tuning Practices for Power Vault MD3600 Series Storage Arrays
2/8
MD3600i Series Array Best Tuning Pract ices
Page ii
THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL
ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR
IMPLIED WARRANTIES OF ANY KIND.
2010-2011 Dell Inc. All rights reserved. Reproduct ion of t his material in any manner whatsoever
without the express written permission of Dell Inc. is strictly forbidden. For more information, contact
Dell.
Del l, the DELL logo, and the DELL badge, PowerConnect, and PowerVaul t are t rademarks of Dell Inc.
Other trademarks and trade names may be used in this document to refer to either the entities
claiming the marks and names or t heir products. Dell Inc. disclaims any proprietary int erest in
t rademarks and trade names other than its own.
March 2011
8/2/2019 Best Tuning Practices for Power Vault MD3600 Series Storage Arrays
3/8
MD3600i Series Array Best Tuning Pract ices
Page 1
ContentsIntroduction ............ ............. ............ ............ ............ ............ ............ ............ ............ ... 2Configuration ........... ............. ............ ............ ............ ............ ............ ............ ............ ... 2Recommendations ... ............ ............ ............ ............ ............ ............. ............ ............ ..... 2
NDIS Only Single Adapter Port .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... 2NDIS Only Two Adapter Ports .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... ..... .... .... .... .... .... .... 3Hardware Initi ator Single Port. .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... ..... .. 3Hardware Initiator Dual Port ......................................................................................... 6
Conclusion ............. ............ ............ ............ ............ ............ ............ ............ ............ ..... 6
8/2/2019 Best Tuning Practices for Power Vault MD3600 Series Storage Arrays
4/8
MD3600i Series Array Best Tuning Pract ices
Page 2
IntroductionThis paper out li nes recommended best tuning pract ices for Windows Microsoft iSCSI Init iat or
configurati ons connect ing to the MD36xxi array. This paper focuses only on implementat ions that use
the Microsoft virt ual miniport implementation. Hardware init iators that provide their own hardware
Storport miniport implementation are beyond the scope of t his paper and wil l not be covered.
Therefore, the informat ion t hat f ollows is based on typical customer Windows conf igurations that runon NDIS drivers only, or NDIS driver implementat ions t hat also provide iSCSI off load capabil it ies. The
network cards used to generate this informat ion are t he 10GBase-T Intel Server AT adapter, and the
Dell Broadcom 57710 10GBase-T adapt er.
ConfigurationThe host configurati on used in t his report is an R910 with 32GB of memory instal led; t wo 10GBase-T
PCIe GEN2 x8 adapters install ed in PCIe GEN2 x8 elect ri cal slots; and Windows 2008 Standard SP2
instal led. Host and MD36xxi connect to a Dell Power Connect 8024 10GBase-T swi tch with j umbo frames
enabled. Defaul t set t ings are used on Microsoft iSCSI Soft ware Init iat or.
RecommendationsThe foll owing recommendati ons are based on a single host connectivit y solut ion that has one or t wo
10GBase-T single port network adapters install ed, and a duplex MD36xxi confi gurati on. The host is a
Windows 2008 Standard server wi th SP2 and MD36xxi mult i-path host soft ware installed.
NDIS Only Single Adapter Port
For a single net work adapter, four iSCSI connecti ons are recommended between host and arrayone
connection per array host port , two connect ions per array controll er. The recommend MTU size is the
standard Ethernet f rame size of 1518 bytes; j umbo frames are not recommended. If you are using Inteland your system support s input / output accelerat ion t echnology (IOAT), we recommend that this
feature and the IOAT drivers be installed. We also recommend that you enable RSS in t he operating
system, conf igure the number of RSS queues on the adapter t o be equivalent to the number of CPU
cores on the system, and set t he receive and transmit buff er size to maximum values. Use the default
value for all ot her set t ings. For Broadcom, we recommend that Chimney and RSS support be enabled
and default adapter set t ings be used. For a single 10GBase-T port implement ation, f our iSCSI
connections are recommended between host and target .
8024
SW
R910N0
N1
C0
C1
0
1
0
1
8/2/2019 Best Tuning Practices for Power Vault MD3600 Series Storage Arrays
5/8
MD3600i Series Array Best Tuning Pract ices
Page 3
NDIS Only Two Adapter Ports
For a two network adapter confi guration, f our iSCSI connect ions are recommended between host and
arrayone connection per array host port , t wo connections per array control ler . The recommend MTU
size is the standard Ethernet frame size of 1518 bytes; j umbo frames are not recommended. If you are
using Intel and your system supports IOAT, we recommend that t his feature and the IOAT drivers be
instal led. We also recommend that you enable RSS in the operati ng system, configure the number ofRSS queues on the adapter to be equivalent to the number of CPU cores on the system, and set the
receive and t ransmit buffer size to maximum values. Use the default value for al l ot her sett ings. For
Broadcom, we recommend t hat Chimney and RSS support be enabled and default adapter set t ings be
used. For a t wo 10GBase-T port implement ation, four iSCSI connections are recommended between
host and target.
Hardware Ini t iator Single Port
For a single net work adapter, two iSCSI connecti ons are recommended bet ween host and arrayone
connection per array host port and one connection per array cont roll er. Enable j umbo frames on the
host , switch, and array. Set the host adapter MTU to 4500 bytes, and set switch and MD36xxi MTU size
to a value greater t han 4500 byte (a 9000 byte MTU size is recommended for bot h switch and array).
The Dell Modular Disk Storage Manager can be used to confi gure j umbo frames on the MD36xxi.
R910N0
N1
C0
C1
0
1
0
1
8024
SWR910
C0
C1
N0
N1
0
1
0
1
8/2/2019 Best Tuning Practices for Power Vault MD3600 Series Storage Arrays
6/8
MD3600i Series Array Best Tuning Pract ices
Page 4
To configure j umbo frames on the array, open a management connection wit h the array, select the
Setup tab on the main screen, and then click Configure iSCSI Host Ports. The following management
screen displays:
8/2/2019 Best Tuning Practices for Power Vault MD3600 Series Storage Arrays
7/8
MD3600i Series Array Best Tuning Pract ices
Page 5
Click the Advanced Host Port Settings but ton in the lower left of t he window to display the fol lowing
configuration window:
In the Jumbo Frames section, check the Enable j umbo frames box and set the MTU size to 9000
bytes/ frame. Click the OK button. Perform t his operat ion on each MD36xxi iSCSI host port .
8/2/2019 Best Tuning Practices for Power Vault MD3600 Series Storage Arrays
8/8
MD3600i Series Array Best Tuning Pract ices
Page 6
Hardware Init iator Dual Port
For a two network adapter confi guration, f our iSCSI connect ions are recommended between host and
arrayone connect ion per array host port , two connect ions per array cont roll er. Enable j umbo frames
on the host , switch, and array. Set the host adapter MTU to 4500 bytes, and set switch and MD36xxi
MTU size t o a value greater t han 4500 byte (a 9000 byte MTU size is recommended for bot h switch and
array). The Dell Modular Disk Storage Manager can be used to configure j umbo frames on the MD36xxi.
ConclusionIn general, when conf iguring MS iSCSI Init iator on a system running NDIS dri vers on a 10GBase-T
adapter, we recommend no more than four iSCSI sessions between host and array. This wi ll provide
adequate st reaming capabil it y between host and array without overwhelming the host adapter port .
For iSCSI hardware init iat ors, t he number of iSCSI connections between host and array can be fewer f or
the single adapter port case. These guideli nes are meant to provide a general confi gurat ion t opology
based on a typi cal 10GBase-T host connection profil e, but every sit uati on is unique and may require a
dif ferent set of guidelines. If t his is the case, contact Dell Technical Support for further assistance.
8024
SW
R910N0
N1
C0
C1
0
1
0
1