XN-9000 AUTOMATED HEMATOLOGY SYSTEMS
BEYOND A BET TER BOX™
Reshaping Scalable Automation
2
Sysmex® XN-Series Automated Hematology Analyzers are designed to exceed the expectations of real people who work in real labs by delivering accuracy, quality and dependability.
3
B E Y O N D T E C H N O L O G Y, B E Y O N D T O D A YSysmex® XN-9000 Automated Hematology Systems represent a major advancement in automation. Sysmex technology goes “beyond a better box” by surrounding our systems with an intuitive ecosystem to help improve lab operations, promote better outcomes and enhance your patient management practices.
T H E F U T U R E O F A U T O M A T I O N I S A L R E A D Y H E R E
4
NEXT GENERATION DIAGNOSTICS
Advanced clinical parameters: • Leukopoieticindicators—Immaturegranulocyteswitheverydifferential• Erythropoieticindicators—NucleatedRBCwitheveryCBC,reticulocytehemoglobin
(Ret-He) and immature reticulocyte fraction (IRF) • Thrombopoieticindicators—Immatureplateletfraction(IPF)andafluorescentplatelet
count(PLT-F)designedforverylowplateletcounts
PROCESS OPTIMIZATION
• Flexiblemodulardesignforscalabilityand future expandability
• Remarkablysmallerfootprinttooptimizeincreasinglyprecious laboratory space
• Theabilitytomanage>90% of all EDTA tube testing (Hematology and HbA1c)
ADVANCED TOOLS AND TECHNOLOGIESProductivityandefficiencyenhancementsthat are supported by: • Auto-validation• Automaticworkloadbalancing• Rerun/reflextesting• Reflexiveslidepreparation
HARMONIZED SUPPORT
• Work-flowassessmentandoptimization
• Comprehensivecontinuingeducation
• InsightTM IQAP
• BeyondCareSM
A DVA N C E D TO O LS& T E C H N O LO G I E S
H A R M O N I Z E DSU P P O RT
NE
XT
GE
NE
RA
TIO
ND
IAG
NO
ST
ICS
PR
OC
ES
SO
PT
IMIZ
AT
ION
STREAMLINED REAGENT MANAGEMENT
Smaller, lighter reagent containers are color-coded from container to software reagent screen and designed to fit perfectly within the XN-Series system wagons. Sysmex® XN-9000 Automated Hematology Systems use the RU-20 Concentrated Reagent Delivery System to provide diluent from a 25X concentrate. Lab directors can enjoy fewer reagent changes that will provide greater instrument availability and improved workflow.
5
6
LAVENDER TOP MANAGEMENT® WITH SYSMEX WAM™ MIDDLEWARE
SysmexWAMisatotallavendertopinformationsystemwithsophisticateddecisionrules.Results and specimen management are easily scaled to support a wide range of laboratory environments. It allows your laboratory management to set multi-site and system-wide rulesforstandardizationandauto-validation.
E M P OW E R I N G T O D AY ’ S H I G HP E R F O RM A N C E L A B
7
FULL AUTOMATION HAS CHANGED FOREVER
Sysmex® XN-9000, scalable, automation hematology systems provide different levels of efficiencies to meet the needs of laboratoriesofanysizeandcomplexityofpatientmixthrough its scalable and modular design. Modules that can be part of this system include XN-10,SP-10, DI-60 (slide processing system), TS-10/10-H(integratedtubesorter/archiver)andintegrated HbA1c testing module (Bio-Rad VARIANT II TURBOTM Link).
If you manage a laboratory that needs to integrate workstations andimproveturnaroundtime,laborutilizationandpatientcare,this istheperfectsystemtomeetallofyourtestingneedsintoday’s time-crunched and economically challenging healthcare environment.
OU R S P E C I F I C A T I O N S S P E A K VO LUM E S . . .
WBC,RBC,HGB,HCT,MCV,MCH,MCHC,PLT(PLT-I),NRBC%,NRBC#,RDW-SD,RDW-CV,MPV
NEUT%,LYMPH%, MONO%, EO%, BASO%, IG%,NEUT#,LYMPH#,MONO#,EO#,BASO#,IG#
WBC-BF,RBC-BF,MN%,MN#,PMN%,PMN#,TC-BF#(BodyFluids,BLicense)
PLT(PLT-F),IPF(Platelets,PLicense)
RET%, RET#, IRF, RET-He (Reticulocytes, R License)
Reportable parameters by channel
Dimensions• Line:~13.1’wx4’d
• Clearanceinfront~2.5’
• Clearanceinback~18”
ComponentsSample/rackmanagementmodules:# XN-10:# XN-20*:#SP-10:Body fluid license (B):PLT-Flicense(P):Reticulocyte license (R):
ST-40/41, BT-40,WG-50 and 60201IncludedIncludedIncluded
Quality control • XNCHECK. Complete tri-level QC product for all CBC, Diff, PLTandReticulocyteparameters • XNCHECK BF. Bi-level QC product for Body Fluid channel
Description • Scalableautomation • Automaticworkloadbalancing • Fullyautomatedreflexiveslidepreparation• Increasedproductivity • Hands-freererun/reflex • Modular
Optimum peak hour profile • Up to 200/hr
IPU decision rules environment• Pre-loadedtemplatewithintheXN-SeriesIPU(PC) • Customereditable/adjustable • Easilyenabled/disabled • NearpaperlessenvironmentwhenusingtheIPU(print‘positive’only) • ExceptionsamplereviewandreleaseatLIS(oncelabsetsupLIStoreleaseandholdresultsaccording
to specific indicators received from XN)• IPUrulesnotinusewhenSysmexWAMisselectedasanoption
Enhanced reagent management • RFID(RadioFrequencyID)tagsforhands-freeinformationmanagementofcartridgereagents • Colorcodingofreagentsfromcontainertosoftwaredisplayforincreasedoperatoreaseandconvenience • Concentratedreagentoption • Floor-standingwagonoptionforreagentstorage,managementandincreasedconvenience
8
*Not available in the U.S.
S Y S M E X ® X N - 9 0 0 0 A U T O M A T E D H E M A T O L O G Y S Y S T E M S
XN9000-201-BPR
Concentrated reagent/diluter (RU-20) RU-20(reagentunit)—dilutesconcentrateddiluent(CELLPACK® DST) tocreateready-to-useCELLPACK® DCL . Recommended minimum workload is 55 samples per day when using the 2 x 4L packaging, 200+ samples per day when using the 20L packaging. One RU-20 supplied with every three XN-10 modules. XN9000-401-BPRsuppliedwithtwoRU-20 systems
Flexible sample loading/unloading Right-side sample loading and unloading is standard for all configurations Alternateloading/unloadingoptionse.g.leftsideloadingandunloading are also available
Network printer Yes
XN IPU(s) Mounted at ST-40 component on right side
Process controller software—XN-IC™ 1)ProvidesasingleinterfaceforALLXN-10andSP-10 modules on the line 2) Includes basic smear processing rules (smears on positive results)
9
XN9000-201-BPR
P R OV I D I N G T H E U LT I M A T E F L E X I B I L I T Y
ComponentsSampler/RackManagement:# XN-10:# XN-20*:#SP-10:Body Fluid License (B):PLT-FLicense(P):Reticulocyte License (R):
ST-40/41, BT-40,WG-50 and 60301IncludedIncludedIncluded
Dimensions• Line:~15.1’wx4’d
• Clearanceinfront~2.5’
• Clearanceinback~18”
Optimum peak hour profile • Up to 300/hr
10
XN9000-301-BPR
*Not available in the U.S.
S Y S M E X ® X N - 9 0 0 0 A U T O M A T E D H E M A T O L O G Y S Y S T E M S
XN9000-401-BPR
ComponentsSample/rackmanagementmodules:# XN-10:# XN-20*:#SP-10:Body fluid license (B):PLT-Flicense(P):Reticulocyte license (R):
401IncludedIncludedIncluded
Dimensions• Line:~17.1’wx4’d
• Clearanceinfront~2.5’
• Clearanceinback~18”
Optimum peak hour profile • Up to 400/hr
11
*Not available in the U.S.
12
Sysmex WAMDecision support software for the clinical laboratory.ScalableinformaticsandWorkAreaManagement(WAM)platform delivers enhanced sample and data process management.• Comprehensivehematologyinformationmanagementsystem
with auto-validation• SingleinterfacetoLIS• Complexrulesengine;demographic,location,physician,
patient-specific, specimen age and extended delta-checking• Multi-site,multi-LISdataprocessintegration• Paperlessenvironment• Managementreportsmodule
• IspartofLavenderTopManagementconfigurations
XN9000-XN10-BPR• Testmodulesthatincludesthe
XN-10 and track components
• Provides additional testing capacity(additional throughput of up to 100samples / hr)
• Width:~2’
XN9000-SP-10• IncludesSP-10 and track components
toprovideadditionalslidemaking/ staining capacity
• ~3.6’Width
XN9000-TU• Turnunitforimproveddesignflexibility
Left side rack loading and unloading• Additionaltrackcomponentsthatconfiguresline
to provide left side rack loading and unloading
MOR E O P T I ON S M E AN S MO R E E F F I C I E N C Y
XN9000-CV70• Expandableconveyorbridgethatallowsan XN-9000 line to go around fixed objects
• Alsousedtobridgerackflowinpresence of DI-60 module
XN9000-TS-10• Optionforlaboratoriesdesiring
hands-free pre- and post-analytical Lavender Top Management® (LTM) solution
• Idealforlabswithlessthan 450 lavender top tubes through system during multiple peak workload hours
• SysmexLaboratorySolutionsConsultant(LSC)consultation recommended to provide best configuration and placement within the environment line configuration and workflow
• SysmexWAMispartofthesolutiontodriveintegratedsample processing, routing and tracking (on and off the system)
• Dimensions(WxDxH):3.3’X4.3’X5.7’
XN9000-TS-10-H• Optionforlaboratoriesdesiringhands-freepre-andpost-analyticalLavenderTopManagement® (LTM) solution
• Idealforlabswithlessthan950 lavender top tubes through system during multiple peak workload hours
• SysmexLaboratorySolutionsConsultant(LSC)consultationrecommendedtoprovidebestconfigurationandworkflow
• SysmexWAMispartofthesolutiontodriveintegratedsampleprocessing,routingandtracking(onandoffthesystem)• Dimensions(WxDxH):3.3’X4.3’X5.7’
13
XN9000-A1C-1• OptionforLavenderTopManagement(XN-9000 with TS) configurations
• Moduleconsistingofx1 Bio-Rad VARIANT II TURBO™ Link instrument and automation track components
• RequirestubesorterandSysmexWAMtoprovideintegrationofsample data process management
• Dimension:~7’
XN9000-A1C-Add-On• OptionforLavenderTopManagement(XN-9000 with TS) configurations
• Growthmodule(consistingofx1 Bio-Rad and automation wagon) that can be added and incorporated into existing XN-9000-A1C configurations to increase A1C testing capacity.
• RequirestubesorterandSysmexWAMtoprovideintegrationofsample data process management
• Dimension:~4’
XN9000-A1C-2• OptionforLavenderTopManagement(XN-9000 with TS) configurations
• Moduleconsistingofx2 Bio-Rad VARIANT II TURBO™ Link instrument and automation track components
• RequirestubesorterandSysmexWAMtoprovideintegrationofsample data process management
• Dimension:~11’
XN9000-DI60• Optionsforlaboratoriesthatwanttoautomateandstandardize smear review process
• Moduleincludescellimagingsystem,PCandWagon(WG)thatis ready to integrate with SP-10 or XN-9000 line
• CanbeinterfaceddirectlytoLISortoSysmexWAM
• RequiresanXN9000-CV70 if racks will need to go beyond this module. Specifically when:
– WhenthereisaTS-Seriesproduct(TS-500, 2000, 10 OR 10-H) to the left of the DI-60
– XN-9000 is set up to a left loading configuration
– XN-9000 includes 2ndSP-10 with DI-60
• Dimension:~3’width
S Y S M E X ® X N - 9 0 0 0 A U T O M A T E D H E M A T O L O G Y S Y S T E M S
14
15
E X P LO R E H OW W EC A N T A K E YO U R L A BB E Y O N D A B E T T E R B O X
Sysmex truly understands the complex challenges hematologists are facing andwillfaceinthefuture—andwewillalwaysbecreatingthemeanstosolve them. Our Sysmex® XN-9000 Automated Hematology Systems are agiantstepforwardwithautomationthatmaximizesyourlaboratory’scapacity and productivity.
WeworkhardtoensurethatSysmexcustomersenjoythegreatestpossible return on their investment. From implementation and training to ongoing maintenance and support, every step of our process has been engineered to reduce your operating costs, improve laboratory results and, above all, improve the lives of your patients.
To learn more about how we can help your laboratory move to the next level with Sysmex® XN-9000 Automated Hematology Systems, visit sysmex.com/usorcallusat(800) 379-7639.
© 2015 Sysmex America Inc.MKT-10-1177
Programavailabilityvariesbylocation.Programsandspecificationsubjecttochangewithoutnotice. V05/22/15P05/2015
Sysmex Corporation1-5-1-Wakinohama-Kaigandori Chuo-ku,Kobe651-0073,JapanTel. +81 (78) 265-0521www.sysmex.co.jp
Sysmex America, Inc.577 Aptakisic RoadLincolnshire, IL 60069, U.S.A.Tel. +1 (800) 379-7639www.sysmex.com/us
Sysmex Canada, Inc. 5700 Explorer Drive Suite 200,Mississauga,ONL4W0C6CanadaTel. +1 (905) 366-7900www.sysmex.ca
Sysmex Latin America and the CaribbeanRuaJoaquimNabuco615- BairroCidadeJardimSãoJosédosPinhaisParaná–Brasil–CEP83040-210Tel. +55 (41) 2104-1314www.sysmex.com.br