16
Bias Ring Current Carl Goodrich 2/26/08

Bias Ring Current Carl Goodrich 2/26/08. Carl Goodrich- VELO Meeting2 Sensor: 2552-10 Measurement: IV Data from December V bias Ground

  • View
    213

  • Download
    0

Embed Size (px)

Citation preview

Bias Ring Current

Carl Goodrich

2/26/08

2/26/08 Carl Goodrich- VELO Meeting 2

Sensor: 2552-10 Circuit: 1

0.00

20.00

40.00

60.00

80.00

100.00

120.00

140.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

SA

SB

L

Sensor:2552-10

Measurement:IV

Data from December

Vbias

Ground

2/26/08 Carl Goodrich- VELO Meeting 3

Sensor: 2552-10 Circuit: 3

0.00

20.00

40.00

60.00

80.00

100.00

120.00

140.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

SA

SB

L

Sensor:2552-10

Measurement:IV

Data from February

GroundVbias

2/26/08 Carl Goodrich- VELO Meeting 4

Total Current

0.00

20.00

40.00

60.00

80.00

100.00

120.00

140.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

SA

SB

L

Sensor:2552-10

Measurement:IIVVbias

Ground

Total Current: Bias Ring + Guard Ring

Data from January

2/26/08 Carl Goodrich- VELO Meeting 5

Sensor: 2552-14 Circuit: 1

0.00

20.00

40.00

60.00

80.00

100.00

120.00

140.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

SA

SB

L

Sensor:2552-14

Measurement:IV

Data from December

Vbias

Ground

2/26/08 Carl Goodrich- VELO Meeting 6

Sensor: 2552-14 Circuit: 3

0.00

20.00

40.00

60.00

80.00

100.00

120.00

140.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

SA

SB

L

Sensor:2552-14

Measurement:IV

Data from February

GroundVbias

2/26/08 Carl Goodrich- VELO Meeting 7

Total Current

0.00

20.00

40.00

60.00

80.00

100.00

120.00

140.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

SA

SB

L

Sensor:2552-14

Measurement:IIVVbias

Ground

Total Current: Bias Ring + Guard Ring

Data from January

2/26/08 Carl Goodrich- VELO Meeting 8

Sensor: 2552-11 Circuit: 1

0.00

50.00

100.00

150.00

200.00

250.00

300.00

350.00

400.00

450.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

S1

S2

L

Data from December

Sensor:2552-11

Measurement:IV

Vbias

Ground

2/26/08 Carl Goodrich- VELO Meeting 9

Sensor: 2552-11 Circuit: 1

0.00

50.00

100.00

150.00

200.00

250.00

300.00

350.00

400.00

450.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

S1

S2

L

Sensor:2552-11

Measurement:IV

Data from February

Vbias

Ground

2/26/08 Carl Goodrich- VELO Meeting 10

Sensor: 2552-11 Circuit: 3

0.00

50.00

100.00

150.00

200.00

250.00

300.00

350.00

400.00

450.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

S1

S2

L

Sensor:2552-11

Measurement:IV

Data from February

GroundVbias

2/26/08 Carl Goodrich- VELO Meeting 11

Total Current

0.00

50.00

100.00

150.00

200.00

250.00

300.00

350.00

400.00

450.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

S1

S2

L

Sensor:2552-11

Measurement:IIVVbias

Ground

Total Current: Bias Ring + Guard Ring

Data from January

2/26/08 Carl Goodrich- VELO Meeting 12

Sensor: 2535-8 Circuit: 1

0.00

20.00

40.00

60.00

80.00

100.00

120.00

140.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

SA

SB

L

Sensor:2535-8

Measurement:IV

Data from December

Humidity = 1.1%

Humidity = 8.3%, 9.4%

Vbias

Ground

2/26/08 Carl Goodrich- VELO Meeting 13

Sensor: 2535-8 Circuit: 1

0.00

20.00

40.00

60.00

80.00

100.00

120.00

140.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

SA

SB

L

Sensor:2535-8

Measurement:IV

Humidity = 12.2%

Humidity = 11.5%, 9.1%

Data from February

Vbias

Ground

2/26/08 Carl Goodrich- VELO Meeting 14

Sensor: 2535-8 Circuit: 3

0.00

20.00

40.00

60.00

80.00

100.00

120.00

140.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

SA

SB

L

Sensor:2535-8

Measurement:IV

Humidity = 9.4%

Humidity = 12.6%, 8.3%

Data from February

GroundVbias

2/26/08 Carl Goodrich- VELO Meeting 15

Total Current

0.00

20.00

40.00

60.00

80.00

100.00

120.00

140.00

0 200 400 600 800 1000 1200

Voltage (V)

Cu

rren

t (n

A)

SA

SB

L

Sensor:2535-8

Measurement:IIVVbias

Ground

Data from January

Total Current: Bias Ring + Guard Ring

Humidity = 8.0%

Humidity = 7.5%, 7.6%

2/26/08 Carl Goodrich- VELO Meeting 16

Conclusions

• Biasing the rubber pad seems to affect the IV curves in two ways:– Causes the current to gradually increase

especially after 600V– Increases the error

• Not as “pretty”

• More data to suggest that humidity affects the IV curves– However, higher humidity results in a lower

current???