4
Bioclave 12L Aluminum Autoclave Autoclave for sterilization by vapor, modern design, easy to operate, ideal for dentistry offices (general practice, endodontia, pediatric dentistry, orthodontics, prosthesis, operative dentistry and esthetics). Description Plucky and innovative design Tank’s capacity: 12 liters Pressure tank: In Aluminum Quick tank heating and cooling. Safety and resistance to constant heating processes.

Bioclave 12L Aluminum

Embed Size (px)

Citation preview

Page 1: Bioclave 12L Aluminum

Bioclave 12L Aluminum

Autoclave

Autoclave for sterilization by vapor, modern design, easy to operate, ideal for dentistry offices (general practice, endodontia, pediatric dentistry, orthodontics, prosthesis, operative dentistry and esthetics).

Description

Plucky and innovative design

Tank’s capacity: 12 liters

Pressure tank: In Aluminum Quick tank heating and cooling. Safety and resistance to constant heating processes.

Trays: In AluminumExcellent mechanical strength and resistance to temperature ranges keeping its characteristics.

Door: In Ejected Aluminum

Page 2: Bioclave 12L Aluminum

Light and stable openings, assuring appropriate close and sealing during all sterilization cycle.

Door’s Seal ring: Silicon It has excellent flexibility and resistance to temperature and pressure ranges, assuring suitable sealing.

Internal thermal Insulation: Glass woolIt assures that heating cycle occurs with higher speed with no loss of temperature and keeps the device’s external temperature within the acceptable safety limits.

Indication for Monitoring: Manometer (pressure / temperature) It allows suitable monitoring of work temperature and pressure during all sterilization cycle.

Control panel: Positioned at frontal part (indicates operations / control keys) Easy access and handling. It allows operating the device quick and precisely.

Automatic deaerationIt assures uniform and constant temperature in the tank during sterilization cycle.

Supply voltage: 127 and 220 volts (with reversing switch) It allows being turn on in any output voltage within operating range. It is turned on in 127V (between 102V and 152V) and 220V (between 198V and 264V).

* 18 Safety Systems

1 – Electronic time and temperature micro-controlled system. It assures the repeatability of sterilization processes within the specified limits.

2 – Emergency keyIt is activated by operator which interrupts the cycle in case of emergency.

3 – Electronic system that interrupts sterilization cycleIt actuates if the sterilization cycle does not start in up to 45 minutes, it can occur due to operating fault, lack or excess of water.

4 – TermoswitchIt protects the system against risks of excessive elevation of temperature in resistance assembly.

5 – Two overpressure valve – safety sealIt actuates in case of operating fault where the pressure may exceed safety limits, with the purpose of avoiding overpressure risks.

6 – Anti vacuum under pressure valve The mechanical valve that actuates during door’s opening with the purpose of releasing air flow in order to allow its motion.

7 – Solenoid valveIt actuates in case of power outage, assuring system depressurization.

8 – Silicon ring for door’s sealingIt actuates in case of excessive elevation of pressure.

9 – Device with safety system against accidental doors openingIt assures immediate system depressurization in case of accidental openings, which does not allow that vapor flow displacement is directed to the operator.

10 – Electrical fuse assemblyIt protects against risks of excessive elevation of current.

11 – Rubber feetIt assures total stability to the assembly.

12 - Safety device against accidental opening of doorEnsures immediate depressurization of the system in case of accidental opening. It does not allow the movement of the steam is directed to the operator.

Page 3: Bioclave 12L Aluminum

13 - Set of electrical fusesIt protects against the risk of excessive rise of current.

14 - Rubber feetThey guarantee total stability to the assembly.

15 - Resistance type collar It is safer and more efficient. Avoid fire and consumes less energy.

16 - Cable temperature sensorThe Insulation is resistant to high temperatures.

17 - Copper pipe internalPrevents leakage due to high pressure and temperature.

18 - Main switchEasily accessible, avoids crashes. The Professional can turn it off when needed or when there is a power surge. No need to use the power cord.

* Accessories which accompany the Autoclave 12L Aluminum

External steam outlet’s hoseThis accessory must be connected and fixed to the external steam outlet using a clamp. It takes steam out.

Trays and supportThe support and the two trays keep the materials to be sterilized apart from the chamber’s side walls, from the bottom and from the water.

Graduated glassIt’s used to dose the quantity of distilled water needed for each sterilization cycle.

Tray holderIt’s a device used to handle trays, avoiding direct contact with the operator.

Technical Specifications

Tension of Feeding - 127/220 V (with reversible key)

Frequency- 50/60 Hz

Electrical Protection - fusible

Potency - 1600 VA

Nominal Current - 15A – 127V~ / 8A – 220 V~

Pressure tank - Aluminum

Door Sealing Ring - Silicone

Electronic System - Micro-controlled (time and temperature)

Safety thermostat - Electromechanical type

Water - Manual insertion with dosing cup

Trays - Aluminum

Support - Staninless steel

Page 4: Bioclave 12L Aluminum

Operation temperature - 128ºC ±5 (123 to 133ºC)

Door opening - Depressurization system by lever

Diameter of the chamber - 21.4 cm

Chamber’s depth - 31.8 cm

Dimension - 40.7 cm width x 38.5 high x 46.5 cm deep

Water consumption - 150 -200ml

Net weight - 23 Kg

Volume- 12 liters

Sterilization time - 16 minutes

Complete cycle - 60 minutes These values are approximate; they may change depending on the material’s type and volume, energy oscillation, etc.