Upload
madeleine-pearson
View
213
Download
1
Embed Size (px)
Citation preview
Bodiflo LLCBodiflo LLC 11
BODIFLO LLCBODIFLO LLC
BodiFLO SystemBodiFLO System
Bodiflo LLCBodiflo LLC 22
BodiFLO Background BodiFLO Background Injuries to the head and traumatic brain injury (TBI) make up a Injuries to the head and traumatic brain injury (TBI) make up a
substantial portion of injuries treated in the hospital substantial portion of injuries treated in the hospital emergency room. The most severe often occur in military emergency room. The most severe often occur in military training or combat. training or combat.
TBI is a major consideration with emphasis on rapid TBI is a major consideration with emphasis on rapid evaluation to quantify blood flow and auto-regulatory trends.evaluation to quantify blood flow and auto-regulatory trends.
Bodiflo LLCBodiflo LLC 33
BodiFLO ResearchBodiFLO Research•Develop and test a simple non invasive method to monitor intracranial fluid dynamics.
•Develop and test a non invasive means to measure compartmental fluid volumes in the body.
•Integrate simultaneous display and analysis of the most important physiological parameters into a single CPU/Monitor for the ICU.
Bodiflo LLCBodiflo LLC 44
BodiFLO MissionBodiFLO Mission
BODIFLO IS COMMITTED TO ENHANCING CRITICAL PATIENT BODIFLO IS COMMITTED TO ENHANCING CRITICAL PATIENT CARE BY MINIMIZING INTRUSIVE AND EXPENSIVE MEDICAL CARE BY MINIMIZING INTRUSIVE AND EXPENSIVE MEDICAL
MONITORING AND INTERVENTION.MONITORING AND INTERVENTION.
CURRENT METHODOLOGY IS SUBJECT TO DIAGNOSTIC ERROR CURRENT METHODOLOGY IS SUBJECT TO DIAGNOSTIC ERROR AND IS OFTEN UNSUITABLE FOR FIELD CONDITIONS.AND IS OFTEN UNSUITABLE FOR FIELD CONDITIONS.
IT IS OFTEN VERY INVASIVE TO THE WARRIOR/PATIENTIT IS OFTEN VERY INVASIVE TO THE WARRIOR/PATIENT
Bodiflo LLCBodiflo LLC 55
BodiFLO ThrimBodiFLO Thrim The BODIFLO The BODIFLO
Prototype system Prototype system uses fixed frequency uses fixed frequency bioelectrical bioelectrical impedance impedance plethysmographic plethysmographic techniques to provide techniques to provide information about information about overall segmental overall segmental volumes, blood flows volumes, blood flows (volume), and (volume), and hemodynamic status. hemodynamic status.
..
Bodiflo LLCBodiflo LLC 66
BodiFLO Multi-Frequency REGBodiFLO Multi-Frequency REG Investigations using our 4 Investigations using our 4
channel REG to record 2 channel REG to record 2 hemispheres hemispheres simultaneously with simultaneously with another channel used another channel used simultaneously to record simultaneously to record the extra cranial BBF the extra cranial BBF position.position.
The new multi-frequency The new multi-frequency REG unit can use two REG unit can use two channels for every channels for every frequency.frequency.
Frequencies: 16 kHz, Frequencies: 16 kHz, 100 kHz 100 kHz
and 200 kHz. and 200 kHz.
Bodiflo LLCBodiflo LLC 77
BodiFLO SoftwareBodiFLO Software
Bodiflo software allows for multi-channel recording, Bodiflo software allows for multi-channel recording,
XY Plotting, Replay and analysis of up to 32 channels of XY Plotting, Replay and analysis of up to 32 channels of data in real time. Real time video capture and replay.data in real time. Real time video capture and replay.
Digital output facility (control external devices)Digital output facility (control external devices) Scope Functionality (XY Plot)Scope Functionality (XY Plot)
Bodiflo LLCBodiflo LLC 88
Contact USContact US
BODIFLO LLCBODIFLO LLC Ph: Ph: 1-615-202-9370 1-615-202-9370 4825 Trousdale Drive - STE 109 4825 Trousdale Drive - STE 109 NASHVILLE TN 37220-1364 NASHVILLE TN 37220-1364 Email: Email: [email protected] om Web: Web: www.bodiflo.comwww.bodiflo.com