In case of DP3...operation efficiency UP!Since the threshold level can be automatically changedby the auto-reference function, two suction nozzles canbe used, alternately, with one sensor.
Till now...one sensor was required for each suctionnozzleSince the threshold level differs with the suction nozzle, asensor was required for each suction nozzle, increasingthe cost significantly.
Incorporates Auto-reference Function
DP3LED Display High Functionality Digital Pressure Sensor
High Accuracy Sensingat All Times with Auto-reference Function
710
SERIES
PRES
SURE
SEN
SORS
DP
2D
P-Y
LED
Bar D
ispla
yD
P-M
PE
LED
Dig
ital D
ispl
ayD
P3
MarkedConforming to EMC Directive
• Unaffected by changes in reference pressureBy an external signal, the set (threshold) values are corrected by being shifted by an amount equal to thepressure change. Hence, judgement by the sensor is as accurate as before the reference pressure change.This function is extremely suitable in places havingintense variations in the reference pressure or wherefine settings are required.
• Total cost reduction
For chip components
For trimmers
Example of air-leak test
OK NG
NG? NG OK NG
Threshold level
Reference pressure
Auto-reference function follows reference pressure changes
Pressure sensor not incorporatingauto-reference function DP3 series
Before reference pressure change After reference pressure change
Referencepressure
Reference pressure
change
Referencepressure
Referencepressure
Referencepressure
Referencepressure
Referencepressure
Suction OK Suction NG Suction over
Suction nozzle for trimmersAtmosphericpressure( )
Vacuum
Suction nozzle for chip components
Threshold level for suction nozzle for trimmers
Threshold levelfor suction nozzle for chip components
Before suction
Aut
o-re
fer-
ence
inpu
t
Electromagnetic valve
DP3-80
MODE
The pressure unit can be selected fromsix different systems to suit yourrequirement.
The selectable pressure units differwith the sensor type. When the pres-sure unit is changed, the measuredpressure value and the set valuesare automatically converted.
Pressure changes can also be dis-played in an analog fashion using LEDbars. Hence, sudden pressure changescan be recognized at a glance.
LED bars indicate the pressure levelin steps of 10% F.S., regardless ofthe pressure unit.
711
DP3
PRES
SURE
SEN
SORS
DP
2D
P-Y
LED
Bar D
ispla
yD
P-M
PE
LED
Dig
ital D
ispl
ayD
P3
Two Outputs with Four Independent Settings and Four Output Modes Enable Control as per Your Requirement
Selection from Six Pressure UnitsAnalog Bar Display Peak Hold/Bottom Hold Display
A Wide Variety of Models
High Accuracy • High Resolution • High Speed
Hysteresis modeThe hysteresis of the comparative outputs can be set, as desired, with theset values.
Window comparator modeThe comparative outputs can be madeON or OFF by a pressure within the setrange.Since Comparative Output 1 can be usedas a self-diagnosis output, it is possibleto specify the auto-reference input range.
Note: The auto-reference function acts only on Set Value 3 (P3) and Set Value 4 (P4) of Comparative Output 2.
Forced output modeThe comparative outputs are forciblymaintained in the OFF state in thesensing mode, irrespective of the setvalues.Also, since the comparative outputs can be forcibly made ON or OFF withkey operation, without actually applyingpressure, this mode is suitable for anoperation check or a start-up check.
Leak test modeThis mode is optimally suitable for aleak test since Comparative Output 1can be set to the hysteresis mode andComparative Output 2 can be set to thewindow comparator mode.
It achieves a 2.5ms, or less, responsetime at a high resolution of 1/1,000.It enables highly accurate sensing with itsexcellent repeatability and temperaturecharacteristics.
The peak value or the bottom value ofthe varying pressure can be displayed.This function is convenient for findingthe pressure variation range or fordetermining a reference for pressuresettings.
Selection can be made according tomounting method or place of use.
Note: The response time is 7.5ms, or less, at thetime of auto-reference input.
1 2
3 4
ON
OFF
ON
OFF0
Comparative Output 1
Comparative Output 2
Hysteresis
High pressure(Positive pressure type)High vacuum(Vacuum pressure type)
Hysteresis
Set Value 1 Set Value 2 Set Value 3 Set Value 4(P1)
(Note)
(P2) (P3) (P4)
ON
OFF
ON
OFF0
Comparative Output 1
Comparative Output 2
Hysteresis Hysteresis
Hysteresis Hysteresis
Set Value 1 Set Value 3(P1)
(Note)
(P2) (P3) (P4)Set Value 2 Set Value 4
High pressure(Positive pressure type)High vacuum(Vacuum pressure type)
ON
OFF
ON
OFF0
Comparative Output 1
Comparative Output 2
Hysteresis(Variable)
Hysteresis(Fixed)
Hysteresis(Fixed)
Set Value 1 Set Value 2 Set Value 3 Set Value 4(P1)
(Note)(P2) (P3) (P4)
High pressure(Positive pressure type)High vacuum(Vacuum pressure type)
ON
OFFON
OFF
MODE MODEPress key
Sensing mode Forced output mode
ComparativeOutput 1
ComparativeOutput 2
Sensing mode
Press key
Hysteresis: 1 digit (2 digits when using psi unit)
Response time2.5ms or less
RepeatabilityWithin50.2% F.S.51 digit
Temperature characteristicsWithin51% F.S.
Optimum for leak test Suitable for start-up check
: Positive pressure type: Vacuum pressure type
inHg kPa
mmHg psi bar
(Note) kgf/cm2
International System of Units (SI)
DP3-41 100kPa
OUT2OUT1
MODE
0-ADJ
Peak value
Bottom value
Peak value is displayed if key is pressed continuously.
Bottom value is displayed if key is pressed continuously.
DP3-41 100kPa
OUT2OUT1
MODE
0-ADJ
Pre
ssur
e
Time
Analog bar display Digital display
Note: ‘MPa’ in case of DP3-22 and DP3-42.Note: The above graph is for a positive pressuretype sensor.
Hysteresis (fixed): 1 digit (2 digits when using psi unit)
Note: The auto-reference function acts only on Set Value 3 (P3) and Set Value 4 (P4) of Comparative Output 2.
Note: The auto-reference function acts only on Set Value 3 (P3) and Set Value 4 (P4) of Comparative Output 2.
Standard type/DP3-2 M
Flat type/DP3-4 M Light weight type/DP3-80
MODE
Direct piping
Direct mounting on a wall
Mounting on apanel
DP2-20
–101.3kPa
OUT2
OUT1
MODE
0-ADJ
DP2-20
–101.3kPa
OUT2
OUT1
MODE
0-ADJ
Total weight70g approx.
The sensorcan bemounted onthe suctionhead of a chipmounter.
( ) ( )
DP3
712
PRES
SURE
SEN
SORS
DP
2D
P-Y
LED
Bar D
ispla
yD
P-M
PE
LED
Dig
ital D
ispl
ayD
P3
Type Appearance Rated pressure range Model No. Pressure port
APPLICATIONS
ORDER GUIDE
Confirmation of chip component suctionThe auto-reference function can com-pensate for the difference in suctionlevels due to suction nozzle separationdistance. The vacuum type can bemounted close to the chip mountersuction head since it weighs only 70g.
Air-leak test for PET bottlesLeak test mode, which is an outputmode optimally suitable for an air-leaktest, has been incorporated. It can reli-ably detect even a small air- leak.Because of the auto-reference func-tion, it is safe even if the filling pressurevaries.
IC
IC tray
DP3-80
MODE
DP3-41
100kPa
OUT2
OUT1MODE
0-ADJ
DP3-41
0 to1101.3kPa
0 to 1.000MPa
0 to 100.0kPa
0 to1101.3kPa
0 to 100.0kPa
0 to 1.000MPa
DP3-80
DP3-22
DP3-21
DP3-20
DP3-41
DP3-42
M5 female thread
Rc (PT) 1/8female thread
Rc (PT) 1/8female thread
Vac
uum
pre
ssur
e
Ligh
t wei
ght
Pos
itive
pre
ssur
e
Sta
ndar
d
Vac
uum
pres
sure
110
1kP
a ty
pe1M
Pa
type
100k
Pa
type
110
1kP
a ty
pe
Pos
itive
pre
ssur
e
Fla
t
1MP
a ty
pe10
0kP
a ty
pe
713
DP3
PRES
SURE
SEN
SORS
DP
2D
P-Y
LED
Bar D
ispla
yD
P-M
PE
LED
Dig
ital D
ispl
ayD
P3
OPTIONS
Designation
Sensor mountingbracket(For standard type)
Mounting bracket for standard typeTwo M4 (length 6mm) pan head screws and two spring washersare attached.
Changes the pressure port from female thread [Rc (PT) 1/8] tomale thread [R (PT) 1/8].
It can be used for mounting on a panel (1 to 3.2mm thick).
It protects the sensor’s adjustment panel.(It can be fitted when the panel mounting bracket is used.)
MS-DPX
DPX-03
MS-DPX-2
DPX-04
Straight bush
Panel mountingbracket(For standard type)
Front protectioncover(For standard type)
Model No. Description
Panel mounting bracket, Front protection cover
Sensor mountingbracket
Straight bush
DP2-20
–101.3kPa
OUT2
OUT1
MODE
0-ADJ
Front protectioncover DPX-04
Panel mounting bracketMS-DPX-2 Suitable for 1 to 3.2mm thick panel( )
Straightbush
Two M4 (length 6mm) panhead screws and two springwashers are attached.
[ ]
Type of pressure
Rated pressure range
Set pressure range(Note 1)
Settable range(Note 2)
Pressure withstandability
Applicable fluid
Selectable units
Supply voltage
Current consumption
Comparative outputsComparative Output 1Comparative Output 2
Utilization category
Output modes
Hysteresis
Repeatability
Response time
Short-circuit protection
Auto-reference input
Display
Displayable pressure range
Analog bar display
Comparative Output 1
Comparative Output 2
Pollution degree
Protection
Ambient temperature
Ambient humidity
EMC
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Temperature characteristics
Pressure port
Material
Cable
Cable extension
Weight
Accessories
DP3
714
PRES
SURE
SEN
SORS
DP
2D
P-Y
LED
Bar D
ispla
yD
P-M
PE
LED
Dig
ital D
ispl
ayD
P3
Env
ironm
enta
l res
ista
nce
SPECIFICATIONS
Gauge pressure
0 to1101.3kPa 0 to 100.0kPa 0 to 1.000MPa
5.1 to1101.3kPa15.0 to 100.0kPa 10.050 to 1.000MPa
101.3 to1101.3kPa1100.0 to 100.0kPa 11.000 to 1.000MPa
490kPa 1.47MPa
Non-corrosive gas
kPa, kgf/cm2, bar, psi, mmHg, inHg kPa, kgf/cm2, bar, psi MPa, kgf/cm2, bar, psi
12 to 24V DC % Ripple P-P 10% or less
50mA or less
NPN open-collector transistor• Maximum sink current: 100mA• Applied voltage: 30V DC or less (between comparative output and 0V)• Residual voltage: 1V or less (at 100mA sink current)
0.4V or less (at 16mA sink current)
DC-12 or DC-13
Equipped with 4 types of modes: hysteresis mode, window comparator mode, leak test mode, forced output mode(selectable by key operation)
1 digit (however, variable in hysteresis mode, variable for Comparative Output 1 only when using leak test mode, and 2 digits when using psi unit)
Within50.2% F.S.51 digit
2.5ms or less [7.5ms or less with auto-reference input (Note 3)]
Incorporated
Input signal condition: NPN non-contact input [operates in Low (fall) state]High...5 to 30V or openLow...0.4V or less (0.5mA, or less, source current)Low level input time...1ms or moreReference pressure duration...1ms or more
31/2 digit red LED display (Sampling rate: 4 times/sec. approx.)
5.1 to1101.3kPa15.0 to 100.0kPa 10.050 to 1.000MPa
LED bar display in steps of 10% F.S. approx.
Orange LED (lights up when Comparative Output 1 is ON)
Green LED (lights up when Comparative Output 2 is ON)
3 (Industrial environment)
IP40 (IEC)
110 to`507C (No dew condensation or icing allowed), Storage: 110 to`607C
35 to 85% RH, Storage: 35 to 85% RH
Emission: EN50081-2, Immunity: EN50082-2
1,000V AC for one min. between all supply terminals connected together and enclosure
50MΩ, or more, with 500V DC megger between all supply terminals connected together and enclosure
10 to 150Hz frequency, 0.75mm amplitude in X, Y and Z directions for two hours each
100m/s2 acceleration (10G approx.) in X, Y and Z directions for three times each
Over ambient temperature range 110 to`507C: within51% F.S. of detected pressure at 207C
Standard type: Rc (PT) 1/8 female thread, Flat type: Rc (PT) 1/8 female thread, Light weight type: M5 female thread
Front case: ABS, Rear case: PPS (glass fiber reinforced), Display surface: AcrylicPressure port attachment: Die-cast zinc alloy [Light weight type: POM (glass fiber reinforced), pressure port is brass (nickel plated)]
0.15mm2 5-core oil resistant cabtyre cable, 2m long
Extension up to total 100m is possible with 0.3mm2, or more, cable.
Standard type: 95g approx., Flat type: 120g approx., Light weight type: 70g approx.
DPX-02 (Hexagon-socket-head plug for pressure port): 1 No. (Standard type only), Pressure unit label: 1 No.
Vacuum pressure Positive pressure 1101kPa type 100kPa type 1MPa type
Standard Light weight Standard Flat Standard Flat
DP3-20 DP3-80 DP3-21 DP3-41 DP3-22 DP3-42
Type
Item Model No.
0.052 to11.033kgf/cm2, 0.051 to11.013bar0.74 to114.70psi, 38 to1760mmHg1.5 to129.9inHg
10.051 to 1.020kgf/cm2, 10.050 to 1.000bar10.72 to 14.50psi
10.51 to 10.20kgf/cm2, 10.50 to 10.00bar17.2 to 145.0psi
1.033 to11.033kgf/cm2, 1.013 to11.013bar14.70 to114.70psi, 760 to1760mmHg29.9 to129.9inHg
11.020 to 1.020kgf/cm2, 11.000 to 1.000bar114.50 to 14.50psi
110.20 to 10.20kgf/cm2,110.00 to 10.00bar1145.0 to 145.0psi
0.052 to11.033kgf/cm2, 0.051 to11.013bar0.74 to114.70psi, 38 to1760mmHg1.5 to129.9inHg
10.051 to 1.020kgf/cm2,10.050 to 1.000bar10.72 to 14.50psi
10.51 to 10.20kgf/cm2,10.50 to 10.00bar17.2 to 145.0psi
Operationindicators
Notes: 1) The set pressure range is the settable pressure range for Set Value 1 (P1) and Set Value 2 (P2).2) The settable range is the settable pressure range for Set Value 3 (P3) and Set Value 4 (P4). It caters to the auto-reference function and is much wider
than the rated pressure range.3) Refer to ‘Time chart ’ under ‘Auto-reference function’ on P.718.
`10115
( )
715
DP3
PRES
SURE
SEN
SORS
DP
2D
P-Y
LED
Bar D
ispla
yD
P-M
PE
LED
Dig
ital D
ispl
ayD
P3
I/O CIRCUIT AND WIRING DIAGRAMS
PRECAUTIONS FOR PROPER USE
I/O circuit diagram
Note: If you do not use the auto-reference input (pink),always connect it to `V (brown).
Symbols ... D: Reverse supply polarity protection diodeZD1, ZD2: Surge absorption zener diodeTr1, Tr2 : NPN output transistor
Wiring diagram
Tr2
Tr1
ZD1
ZD2
D
12 to 24V DC`10115 %
`
1
Sen
sor
circ
uit
Color code
(Brown)`V
LoadLoad
100mA max.
100mA max.(Blue) 0V
(White) Comparative Output 2
(Black) Comparative Output 1
(Pink) Auto-reference (Pink) input (Note)
Users’ circuitInternal circuit
Blue
Brown
White
Pink
BlackLoad
12 to 24V DC`10115 %
`
1
DP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
Load
• This product is not a safety sensor. Its use is notintended or designed to protect life and preventbody injury or property damage from dangerousparts of machinery. It is a normal pressuredetection sensor.
• The DP3 series is designed for use with non-corrosive gas. It cannot be used with liquid or cor-rosive gas.
Others• Use within the rated pressure range.• Do not apply pressure exceeding the pressure with-standability value. The diaphragm will get damaged andcorrect operation shall not be maintained.
• Do not use during the initial transient time (0.5 sec.) afterthe power supply is switched on.
• Avoid dust, dirt, and steam.• Take care that the sensor does not come in direct contactwith water, oil, grease, or organic solvents, such as,thinner, etc.
• Do not insert wires, etc., into the pressure port. Thediaphragm will get damaged and correct operation shallnot be maintained.
• Do not operate the keys with pointed or sharp objects.
Wiring• Make sure to carry out the wiring in the power supply offcondition.
• Verify that the supply voltage variation is within the rating.• If power is supplied from a commercial switching regulator,ensure that the frame ground (F.G.) terminal of the powersupply is connected to an actual ground.
• In case noise generating equipment (switching regulator,inverter motor, etc.) is used in the vicinity of this sensor,connect the frame ground (F.G.) terminal of the equipmentto an actual ground.
• Do not run the wires together with high-voltage lines orpower lines or put them in the same raceway. This cancause malfunction due to induction.
All models
DP3
716
All models
PRECAUTIONS FOR PROPER USE
Displays measured pressure, settings, errormessages and key-protect status.
Lights up when Comparative Output 1 is ON.
Lights up when Comparative Output 2 is ON.
• Each press of the key changes the selectedmode to sensing mode, Set Value 1 (P1) lSet Value 4 (P4) set mode.
• In the sensing mode, if the key is pressedcontinuously for about 3 sec., key-protect canbe set/released.
• In the sensing mode, if the mode selection key is pressed while pressing the incrementkey( ), the initial setting mode is obtained.
• In the initial setting mode, pressing thekey changes the settable digit.
• In the Set Value 1 to 4 modes, press-ing the key changes the set value tothe high pressure side in case ofpositive pressure type sensor and tothe high vacuum side in case ofvacuum pressure type sensor.
• In the sensing mode, if the key ispressed continuously for 4 sec. or more, the display shows peak hold value.
• In the initial setting mode, pressing thekey changes the set conditions.
• In the Set Value 1 to 4 modes, press-ing the key changes the set value tothe low pressure side in case ofpositive pressure type sensor and tothe low vacuum side in case ofvacuum pressure type sensor.
• In the sensing mode, if the key ispressed continuously for 4 sec. or more,the display shows bottom hold value.
31/2 digit LEDdisplay (Red)
Comparative Output1 operation indicator(Orange)
Comparative Output2 operation indicator(Green)
4
5
6
1
2
3
Increment key ( )
Mode selection key ( )
Decrement key ( )
In th
e se
nsin
g m
ode,
if b
oth
the
keys
are
pre
ssed
si
mul
tane
ousl
y, z
ero-
poin
t adj
ustm
ent i
s do
ne.
Functional description
DP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
1
23
64
5
Label for change in pressure unit• When a pressure unit other than ‘kPa’ ( ) or ‘MPa’ ( ) has
been selected in the initial setting mode, the label (suppliedas accessory) which corresponds to the selected unit should be stuck at the position shown in the figure below.
Pressure unit label (accessory)
DP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
Conversion of pressure units• In the DP3 series, the conversionto different units is automaticallydone on changing the setting ofthe pressure unit. However, thisconversion can also be obtainedby multiplying the values by thecoefficients given in the table onthe right.
Conversion procedure
• For example, if 2kPa is to be expressedin kgf/cm2,
since 1kPa41.0197221012kgf/cm2,2kPa becomes 221.0197221012c0.020kgf/cm2.
Description Function
Stick the pressure unit labelat the position shown.
PRES
SURE
SEN
SORS
DP
2D
P-Y
LED
Bar D
ispla
yD
P-M
PE
LED
Dig
ital D
ispl
ayD
P3
MODE
Error message Cause Corrective action
00
00
00
00
Overcurrent due to short-circuit.
Pressure is being appliedduring zero-point adjust-ment.
Applied pressureexceeds the upperlimit of displayablepressure range.
Applied pressureexceeds the lowerlimit of displayablepressure range.
Applied pressureexceeds the lowerlimit of displayablepressure range.
Applied pressureexceeds the upperlimit of displayablepressure range.
Switch off the power supplyand check the load.
Applied pressure at thepressure port should bebrought to atmospheric pres-sure and zero-point adjust-ment should be done again.
Applied pressure should bebrought within the ratedpressure range.
Error messages• When an error occurs, take the following corrective action.
Pos
itive
pres
sure
type
Vac
uum
pres
sure
type
Pos
itive
pres
sure
type
Vac
uum
pres
sure
type
kPa MPa kgf/cm2 bar psimmHg
inHg atm(Torr)
1kPa 1 121013 1.0197221012 121012 1.4503821011 7.50062 0.2953 9.8692321013
1MPa 12103 1 1.01972210 1210 1.450382102 7.500622103 0.29532103 9.86923
1kgf/cm2 9.80665210 9.8066521012 1 9.8066521011 1.42234210 7.355592102 2.8959210 9.6784121011
1bar 12102 121011 1.01972 1 1.45038210 7.500622102 2.953210 9.8692321011
1psi 6.89473 6.8947321013 7.0306521012 6.8947321012 1 5.17147210 2.036 6.8045721012
1mmHg1.3332221011 1.3332221014 1.3595121013 1.3332221013 1.9336821012 1 3.937021012 1.3157921013
(1Torr)
1inHg 3.3864 3.386421013 3.453121012 3.386421012 0.4912 2.5400210 1 3.34221012
1atm 1.013252102 1.0132521011 1.03323 1.01325 1.46960210 7.600002102 2.9921210 1
Conversion table for pressure units
717
DP3PRECAUTIONS FOR PROPER USE
Setting
• If key-protect has been set, make sure to release key-protect before operating the keys. (Please refer to ‘Key-protect function ’ on P.719 for the procedure.)
• Set Value 1 to 4 (P1 to P4) can be made common for all the output modes.• In the positive pressure type sensor, Set Value 2 (P2) and Set Value 4 (P4) can be set only towards the high pressure side
with respect to Set Value 1 (P1) and Set Value 3 (P3), respectively.In the vacuum pressure type sensor, Set Value 2 (P2) and Set Value 4 (P4) can be set only towards the high vacuum sidewith respect to Set Value 1 (P1) and Set Value 3 (P3), respectively.
• Auto-reference function acts on Set Value 3 (P3) and Set Value 4 (P4) only.• Set Value 5 (P5) is the auto-reference input value. If auto-reference input is not applied, Set Value 5 (P5) is zero.• The conditions which are set are stored in an EEPROM. Kindly note that the EEPROM has a life span and its guaranteedlife is 100,000 write operation cycles. However, since the auto-reference input value [Set Value 5 (P5)] is not written intothe EEPROM, it is not included in the number of write operation cycles.
Setting procedure
1 Zero-point adjustment
Adjust zero-point
2 Initial setting
Set ‘Display’, ‘Output mode’,and ‘Unit’
3 Pressure value setting
Enter Set Value 1 to 4(P1 to P4)
Measurement
Commence measurement on completion of setting
1 Zero-point adjustment
• The displayed pressure when the pressure port is leftopen is adjusted to zero.
• The sensor will automatically enter the sensingmode when power is supplied.
• Let the pressure port be at atmospheric pressure(i.e., no applied pressure condition), and press,simultaneously, the increment and decrement keys continuously.
• is displayed and, when the fingers arereleased, zero-point adjustment is completed andthe sensor returns to the sensing mode.
DP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
3 Pressure value setting
• Set Value 1 to 4 (P1 to P4) of the comparative outputs are set.• At each press of key, the mode changes, in rotation, to Set Value 1 (P1) set mode, Set Value 2(P2) set mode, Set Value 3 (P3) set mode, Set Value4 (P4) set mode, Set Value 5 (P5) display mode andsensing mode.
DP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
2 Initial setting• Pressure ‘Unit’, ‘Display’ and ‘Output mode’ of thecomparative outputs are set.
• In the sensing mode, press key while press-ing key.
• Initial setting is displayed.• If sensor is being used for the first time, is displayed.
MODEDP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
3rd digit 2nd digit
Change with key
1st digit
Unit Output mode Display
: kPa or MPa
: kgf/cm2
: bar
: psi
: Hysteresis mode
: Window comparator mode
: Digital display
: Analog bar display
: Leak test mode
: Forced output mode
: mmHg
: inHg
Pos
itive
pr
essu
re ty
peV
acuu
m
pres
sure
type
• If the output mode has been set to the window comparatormode ( ), set the pressure values so that there is a differenceof 3 digits, or more, between Set Value 1 (P1) and Set Value 2(P2) and between Set Value 3 (P3) and Set Value 4 (P4). Also, if the output mode has been set to the leak test mode ( ), setthe pressure values so that there is a difference of 3 digits, or more,between Set Value 3 (P3) and Set Value 4 (P4). However, when unitis set to ‘psi’ ( ), the difference should be 6 digits, or more.
• The pressure values can be set only when the output mode hasbeen set to hysteresis mode ( ), window comparatormode ( ) or leak test mode ( ). If the output mode has been setto the forced output mode ( ), pressure values cannot be set.
MODE
Sensing mode1’ • At the time of auto-reference input, is displayed, and the sensed pressure value is recorded in Set Value 5 (P5).
Sensing mode1 • Sensed pressure value is displayed.
Set Value 5 (P5) display mode6 • Auto-reference input value is displayed.
In case auto-reference input has not been applied, zero is displayed.
Set Value 1 (P1) set mode2 • Enter Set Value 1 (P1) using key and key.
Set Value 4 (P4) set mode5 • Enter Set Value 4 (P4) using key and key.
Set Value 2 (P2) set mode3 • Enter Set Value 2 (P2) using key and key.
Set Value 3 (P3) set mode4 • Enter Set Value 3 (P3) using key and key.
MODEPress key MODEPress key
MODEPress key
MODEPress key MODEPress key
MODEPress key
Aut
o-re
fere
nce
inpu
t
• The settable digit blinks.• The settable digit changes when key is pressed.• The setting is changed when key is pressed.
All models
PRES
SURE
SEN
SORS
DP
2D
P-Y
LED
Bar D
ispla
yD
P-M
PE
LED
Dig
ital D
ispl
ayD
P3
1. Pressure is increased in the PET bottle, and when Set Value 2(P2) is reached, Comparative Output 1 is turned ON and the filling is tightly shut off.
2. After shutting off the filling pressure, the auto-reference input ismade ‘Low’. The filled pressure is recorded in Set Value 5 (P5)as the reference value, and Set Value 3 (P3) and Set Value 4(P4) are corrected.
3. The leakage is measured by Comparative Output 2, 7.5ms, ormore, after the application of the auto-reference input.If the leakage is OK, Comparative Output 2 is ON, and if it isNG, Comparative Output 2 is OFF.
1. By making the auto-reference input ‘Low’ when the PCB mountcomponents are not being sucked, the reference pressure valueis recorded in Set Value 5 (P5), and Set Value 3 (P3) and SetValue 4 (P4) are corrected.
2. Suction confirmation is done by Comparative Output 2, 7.5ms,or more, after the application of the auto-reference input.If suction is OK, Comparative Output 2 is ON, and if it is NG,Comparative Output 2 is OFF.
3. Error due to suction nozzle clogging is detected by the setting ofComparative Output 1. If the nozzle is OK, Comparative Output 1 is OFF, and if it is NG,Comparative Output 1 is ON.
DP3
718
PRES
SURE
SEN
SORS
DP
2D
P-Y
LED
Bar D
ispla
yD
P-M
PE
LED
Dig
ital D
ispl
ayD
P3
PRECAUTIONS FOR PROPER USE
Auto-reference functionPrinciple
• Auto-reference function corrects Set Value 3 (P3) and Set Value 4(P4) of Comparative Output 2 by taking the pressure measured atthe time of auto-reference input as the reference pressure.
<Before auto-reference input >
ComparativeOutput 2
ON
OFF
Atmospheric pressure P3 P4Pressure
<After auto-reference input >
ON
OFF
Atmospheric pressure
Auto-reference input
Pressure change
P3’
P3’4P3`P5
P4’4P4`P5
P5 P4’
ComparativeOutput 2
Pressure
• When there is no auto-reference input, the atmospheric pressureis taken as the reference pressure for Set Value 3 (P3) and SetValue 4 (P4).
• At the time of auto-reference input, the pressure value detected atthat instant is temporarily recorded as Set Value 5 (P5) andbecomes the reference pressure.
• With Set Value 5 (P5) as the reference pressure, Set Value 3 (P3)and Set Value 4 (P4) are automatically corrected to ‘Set Value 3(P3)`Set Value 5 (P5)’ and ‘Set Value 4 (P4)`Set Value 5(P5)’, respectively.
Settable range and set pressure range after correction
• The settable range of Set Value 3 (P3) and Set Value 4 (P4) is widerthan the rated pressure range to cater to the auto-reference function.
• At the time of auto-reference input, if the corrected set valueexceeds the set pressure range, the set value is automaticallycorrected to be within the set pressure range. Hence, pleasesee that the set pressure range is not exceeded.
2101kPa type
100kPa type
1MPa type
Lo
101.3
2100.0
21.000
101.2
299.9
20.999
zzzzzzzzz
zzzzzzzzz
zzzzzzzzz
5.1
25.0
0
0
0
20.1
0.1
0.001
zzzzzzzzzzz
zzzzzzzzzzz
zzzzzzzzzzz
2101.2
99.9
0.999
2101.3
100.0
1.000
UP
Settable range (P3, P4)
Rated pressure range
Set pressure range (P3 and P4 after correction)
zzzzzzzzzzz
zzzzzzzzzzz
zzzzzzzzzzz 20.050
Time chart
Auto-reference input
Comparative Output 2(ON/OFF)
High
Low
Output response time at the time of auto-reference input
Low levelinput time
1ms or more
7.5ms or less
• Maintain the pressure at a constant level for at least 1ms after theauto-reference input is made Low. If used in a transient state, itwill result in wrong operation.
• Use Comparative Output 2 at least 7.5ms after the auto-referenceinput is made low.
• At the time of auto-reference input, is displayed on the 31/2digit LED display for 1 sec. approx., the pressure at that instant isstored temporarily in Set Value 5 (P5), and Set Value 3 (P3) andSet Value 4 (P4) are corrected.
• Since Set Value 5 (P5) and the corrected Set Value 3 (P3’) andSet Value 4 (P4’), after the auto-reference input, are not stored inan EEPROM, they are erased when the power is switched off.
• When the power supply is switched on again, the auto-referenceinput value [Set Value 5 (P5)] is set to zero.
• Although it is not possible to display the corrected Set Value 3(P3’) and Set Value 4 (P4’), it is possible to display the auto-reference input value [Set Value 5 (P5)].
• In case the auto-reference input (pink) is not used, make sure toconnect it to `V (brown).
Application examples
(2) Air-leak test for PET bottles (Using leak test mode)
• Pressure judgement errors due to suction nozzle type, suctionnozzle clogging, reference pressure changes, etc., are eliminatedby the auto-reference function.
• The confirmation of PCB mount component suction is done withComparative Output 2, which is acted upon by the auto-referencefunction, and error due to nozzle clogging is simultaneouslydetected by Comparative Output 1.
0
P5
P2
P1
P4
P3
Auto-reference input
Suction level can be specified with respect to the atmospheric pressure
Suction nozzle clogging error range
P4’4P4`P5P3’4P3`P5
Time
ba
ba
OK product
NG productPre
ssur
e
<Sensing method >
(1) Confirmation of PCB mount component suction (Using hysteresis mode)
• The effect of dispersion in the filling pressure of the PET bottle iseliminated by using the auto-reference function.
• Comparative Output 1 is used to detect the filling pressure, whileComparative Output 2 is used to detect the leakage. SinceComparative Output 1 is not affected by the auto-reference inputfunction, the filling pressure is detected with reference to theatmospheric pressure.
0
P1
P5P2
P3
P4
Auto-reference input
Leakage can be specified with respect to the atmospheric pressure
P4’4P4`P5
P3’4P3`P5
b
a
OK product
NG product
ba
Time
Pre
ssur
e
<Sensing method >
If it is a simple air-leak test, it can be done by directly applyingthe Comparative Output 1 signal (falling signal) to the auto-reference input.
All models
( )
( )
( )
719
DP3
PRES
SURE
SEN
SORS
DP
2D
P-Y
LED
Bar D
ispla
yD
P-M
PE
LED
Dig
ital D
ispl
ayD
P3
• In the sensing mode, press key continuouslyfor about 3 sec. and release it immediatelywhen is displayed.• Key-protect is set and the sensor returns to the
sensing mode.
PRECAUTIONS FOR PROPER USE
Peak hold & bottom hold functions Forced output mode
Key-protect function
• Peak hold and bottom hold functions enable the display ofthe peak value (maximum pressure value in case of thepositive pressure type sensor and maximum vacuum pres-sure value in case of the vacuum pressure type sensor)and the bottom value (minimum pressure value in case ofthe positive pressure type sensor and minimum vacuumpressure value in case of the vacuum pressure type sen-sor) of the varying measured pressure.
• These functions are convenient for finding the pressurevariation range or for determining the reference for pres-sure settings.
• Please note that the peak value and the bottom value data iserased when it is no longer displayed.
• The response time of the comparative outputs becomes slowerduring the peak hold and bottom hold display.
Peak hold display
Initiating peak hold displayDP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
DP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
Displayedalternately
• In the sensing mode, keep key pressed untilis displayed. (4 sec. approx.)
• When the finger is released after is dis-played, the peak value and are displayedalternately.• If the applied pressure exceeds the displayable
pressure range, error message ( or )and are displayed alternately. In this case,bring back the applied pressure to within the ratedpressure range.
• The figure on the left shows the display of avacuum type sensor when the pressure unit hasbeen set to ‘kPa’ ( ).
Ending peak hold displayDP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
• Press key.[• Sensor returns to sensing mode.]
Bottom hold display
Initiating bottom hold displayDP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
DP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
Displayedalternately
• In the sensing mode, keep key pressed untilis displayed. (4 sec. approx.)
• When the finger is released after is displayed, the bottom value and are displayed alternately.• If the applied pressure exceeds the displayable
pressure range, error message ( or )and are displayed alternately. In this case,bring back the applied pressure to within the ratedpressure range.
• The figure on the left shows the display of avacuum type sensor when the pressure unit hasbeen set to ‘kPa’ ( ).
Ending bottom hold displayDP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
• Press key.[• Sensor returns to sensing mode.]
• In the initial setting, if the output mode is set to the forced outputmode ( ), Comparative Output 1, 2 are forcibly maintained atOFF level in the sensing mode, irrespective of Set Value 1 to 4(P1 to P4). Hence, this mode is useful when it is desired to onlydisplay the pressure value without using the comparativeoutputs.Further, if the keys are operated as per the procedure givenbelow, Comparative Output 1, 2 can be forcibly switched eitherON or OFF without applying pressure at the pressure port. Thisis convenient for an operation check of Comparative Output 1, 2or for an inspection before commencing work.The figure below is for a vacuum pressure type sensor with theunit set to ‘kPa’ ( ).
DP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
DP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
Forced output mode
Blinking display of measured pressure
Sensing mode
MODEPress key
[• Sensor returns to sensing mode.]
Each time key is pressed, Comparative Output 2 switches between ON and OFF.(Operation indicator also lights up, turns off.)
Each time key is pressed, Comparative Output 1 switches between ON and OFF.(Operation indicator also lights up, turns off.)
MODEPress key
Time chart
ON
OFF
ON
OFF
Sensing mode Forced output mode Sensing mode
MODEPress key MODEPress key
ComparativeOutput 1
ComparativeOutput 2
• The comparative outputs are held at the OFF level from thetime a change is made to the forced output mode ( ) from theother modes.
• Even if a comparative output is held at the ON level in theforced output mode, it is forcibly brought to the OFF level at thetime the sensor returns to the sensing mode.
• Key-protect is a function which prevents any unintentional changein the conditions which have been entered in each setting modeby making the sensor not to respond to the key operations.
Setting of key-protectDP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
MODE
• In the sensing mode, press key continuouslyfor about 3 sec. and release it immediatelywhen is displayed.• Key-protect is released and the sensor returns to
the sensing mode.
Release of key-protectDP3-80 –101.3kPa
OUT2OUT1
MODE
0-ADJ
MODE
All models
DP3
720
PRES
SURE
SEN
SORS
DP
2D
P-Y
LED
Bar D
ispla
yD
P-M
PE
LED
Dig
ital D
ispl
ayD
P3
PRECAUTIONS FOR PROPER USE
Setting of pressure lead direction• The pressure lead direction can be changed bydismantling the pressure port attachment and changingthe mounting direction. The tightening torque of thehexagon-socket-head bolt (length: 9mm or less) should be0.29Nzm or less.
Note: Make sure to close any unused pressure port with the hexagon-socket-head plug supplied as accessory.
Piping• When connecting a hexagon-socket-head plug or couplingto the pressure port, hold the hexagonal part of thepressure port with a 12mm spanner and make sure thatthe tightening torque is 9.8Nzm or less. Also, in order toprevent any leakage, wind a sealing tape on the couplingwhen connecting.
Standard type
Main body
Hexagon-socket-head bolts
Pressure portattachment
Pressureports
Hexagon-socket-head plug
12mm spanner
Setting of pressure lead direction• The pressure lead direction can be changed bydismantling the pressure port attachment and changingthe mounting direction. The tightening torque of thehexagon-socket-head bolt (length: 9mm or less) should be0.29Nzm or less.
Piping• When connecting a coupling to the pressure port, hold thepressure port attachment with a 16mm (light weight type:10mm) spanner and make sure that the tightening torqueis 9.8N z m or less (light weight type: 1.47N z m or less).Also, in order to prevent any leakage, wind a sealing tapeon the coupling when connecting.
Pressure port attachment
Hexagon-socket-head bolts
2-"4.3mm mounting holes
Pressure port
Main body
16mm(light weight type: 10mm)spanner
Flat type Light weight type
721
DP3
PRES
SURE
SEN
SORS
DP
2D
P-Y
LED
Bar D
ispla
yD
P-M
PE
LED
Dig
ital D
ispl
ayD
P3
DIMENSIONS (Unit: mm)
DP3-80 Light weight type
MODE
30
(11)30
(15.7)(10.8)
6.2
(23.7)41
2-"8, 4.4 deep
2-"4.3 mounting holes
33.5
5
10
18"3.7 cable 2m long
Pressure portM5 female thread 4 deep
23.5(25.8)
Comparative Output 2operation indicator (Green)
Increment key
Decrement key
Comparative Output 1operation indicator (Orange)
Mode selection key
(2.1)
20
(9)
(18)
31/2 digit LED display (Red)
DP3-20 DP3-21DP3-22 Standard type
MODE
(11)30 31.6
(25.8)(2.1)
30
31.6
(6)
(18.9)(10.9)
Increment key
Decrement key Mode selection key
Comparative Output 2operation indicator (Green)
Comparative Output 1operation indicator (Orange)
23.5 5
38.5
Pressure portRc (PT) 1/8 female thread
8
14
13
"3.7 cable 2m long
20
20
12
2-M3 hexagon-socket-head bolts
2-M4
31/2 digitLED display (Red)
(9)
(18)
DP3-41DP3-42 Flat type
MODE
30
(25.8)
(11)30
(15)
44.7
5.7
(19.9)
20
Comparative Output 2 operation indicator (Green)
Increment key
Decrement key
Comparative Output 1 operation indicator (Orange)
Mode selection key
2-"8, 4.4 deep
31/2 digit LED display (Red)
2-"4.3 mounting holes
35
8.2
19.5
16
"3.7 cable 2m long
Pressure portRc (PT) 1/8 female thread
23.5
(27.9)
(2.1)
(9)
(18)
25
40
1120
12.5
20
31.5
5.8
45.5
20
20
5.8
3.6
8
t 1.6
30
2-"4.2 mounting holes
2-"4.2 mounting holes
DP3
722
PRES
SURE
SEN
SORS
DP
2D
P-Y
LED
Bar D
ispla
yD
P-M
PE
LED
Dig
ital D
ispl
ayD
P3
DIMENSIONS (Unit: mm)
MS-DPX Sensor mounting bracket for standard type (Optional)
MS-DPX-2DPX-04 Panel mounting bracket, front protection cover for standard type (Optional)
Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated)
Two M4 (length 6mm) pan head screwsand two spring washers are attached.
Assembly dimensions
Assembly dimensions
MODE
25
30
28.5
11
48.539.5
31.6
14.2
45.8
40
38.5
30
24
2-"4.2 mounting holes
MODE
30
40
40 30
42.7
3
349.7
43.7
42.7
4.5
56
80
36 0.5 0
36 0.5 0
Panel cut-out dimensions
portion shows the front protection cover.Material: Polycarbonate (Front protection cover)
Nylon 6, Stainless steel (SUS304) (Panel mounting bracket)
Note: The panel thickness should be 1 to 3.2mm.