Technologies
Bilfinger Noell GmbH
97080 WürzburgGermanyPhone + 49 931 903-6190Fax + 49 931 [email protected]
Alfred-Nobel-Straße 20
BILFINGER NOELL GMBH
NON-DESTRUCTIVETESTING
References
AT-acoustic emission testing of pressure vessels,
tanks and piping
Pressure tests in Nuclear Power Plant Isar,
Grafenrheinfeld and Neckarwestheim
LT test in NPP Grafenrheinfeld
VT, PT, LT - tests on the construction site - NPP
Olkiluoto 3 as an accredited testing company
VT, PT, UT - tests to nuclear components for
projects in Germany, Finland, France, Italy and
China
VT, PT - Tests on components of flue gas
desulfurizing plants of the power plants Boxberg
and Moorburg
VT, PT, RT – tests on chassis for the W7-X coils
Helium-leak- test superconducting coils and -10components up to a leakage rate of 10 mbar/s
(e.g. W7-X, EDIPO, CERN)
LT - tests at company Kinkele, Germany
VT, PT, MT - tests at company Lurz, Germany
VT, PT - tests for Vattenfall
n
n
n
n
n
n
n
n
n
n
n
BQ_2015_1_en
Donnerstag, 6. August 2015 13:56:02
Scope of Testing - Test Methods AT, VT, PT, LT, MT, UT, RT
Tests according to Industrial Safety Regulation
Development of test concepts for tasks requiring special
supervision (schedule, cost, resource planning, classification
of the pressure equipment)
Preparation of test procedures for routine inspections (RI) of
pipes and containers.
Preparation of documentation for upcoming RI (clearing
permits, coordination of the individual departments)
Routine inspection of pipes and containers;
replacement/repair when necessary
Visual examination (VT)
Direct and indirect (endoscopy) visual examination
General dimensional checks
Penetration test (PT)
UV-test
R/W-test
Dye penetrant test
Magnetic particle test (MT)
Black flux and UV-test
By hand yoke
Ultrasonic test (UT)
Ultrasonic material thickness measurement
Radiographic examination (RT-FAW)
Film evaluation according to EN ISO – standards and ASME
Code with transmitted-light mode equipment
Special test
Paschentest (checking the integrity of electrical insulation)
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Acoustic emission test (AT)
Test of components from the outside (no draining and
opening of sensitive components with associated hazards)
reduction of time, costs, resources
Test performance with operating fluid (no additional static /
corrosive stress)
Leakage detection in pipes, vessels, fittings, tanks
Testing of quality during production
Monitoring quality during the production in real time on
critical components
Safety monitoring during pressure testing of sensitive com-
ponents or those with high risk potential (gas pressure tests)
n
n
n
n
n
n
Leak test (LT)
All Helium methods (for tank Ø =4,5m, H=3m )effective
Bubble test (cover at welds)
Pressure variation test
Quality and welding technology
Internal and external QM-audits based on ISO 9001
Preparation, calculation, qualification, monitoring
and documentation in the field of welding
technology
Health and Safety
Preparation and control of risk assessments and
registration of hazardous substances
Provision of safety officers and training of your
staff
Qualifications / Approvals
Certification level 2 and Level 3 according to
DIN EN 9712/EN 473 respectively to PED for
procedure VT, PT, LT, UT, MT, RT for welds, rolled
products, tubes, forged goods and monocast part
in manufacturing, industry and services
Qualified personnel for piping and pressure vessels
according to BetrSichV and TRBS Nr. 1203
Certification Level 2 according to DIN EN 9712 for
acoustic emission test