DUAL WAVELENGTH TOTAL BILIRUBIN METER BR-501 Mostsuita&fefor jaundice analysis ofneonates. lAuto-zero function Advanced electronic technologies such as Auto-Zero system simplify the operation. lHandles hemolysis and turbidity easily Careful selection of the dual wavelength color filters and the combination of electronic technology minimize the interference of hemolysis and turbidity. Particulary suitable for jaundice examinations of neonates. lEasy set of the sample tube A sample gauge provided on the surface of BR-501. which indicates the proper sample volume to be inspected. Only simple action is required to set the capillary tube into the holder. lAlarm lamp informs user of abnormalities. Alarm lamp signals either abnormal value or situations such as burned out of the bulb, bilirubin concentration of 30mg/ or more, or high hemolysis of 250mg/ or more. iFlexible power source Power requirement is flexible, from 100 to 240 VAC. lEasy lamp replacement Exchange procedure of the lamp is simplicity itself. * - h -tf u m & fco m m m mm <D mm i z x *) mtt a*± ±.^^,V#lto ^- ; e^nK >^s250rn g /dfM _hV^-^ti^^±#

BR-5014lab.ir/userfiles/Shopping_ItemPdf/Pdf_10731_0892.pdf · DUAL WAVELENGTH TOTAL BILIRUBIN METER BR-501 Mostsuita&fefor jaundice analysis ofneonates. lAuto-zero function Advanced

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: BR-5014lab.ir/userfiles/Shopping_ItemPdf/Pdf_10731_0892.pdf · DUAL WAVELENGTH TOTAL BILIRUBIN METER BR-501 Mostsuita&fefor jaundice analysis ofneonates. lAuto-zero function Advanced

DUAL WAVELENGTH TOTAL BILIRUBIN METER

BR-501

Mostsuita&fefor jaundice analysis ofneonates.

lAuto-zero function Advanced electronic technologies such as Auto-Zero system simplify the operation.

lHandles hemolysis and turbidity easily Careful selection of the dual wavelength color filters and the combination of electronic technology minimize the interference of hemolysis and turbidity. Particulary suitable for jaundice examinations of neonates.

lEasy set of the sample tube A sample gauge provided on the surface of BR-501. which indicates the proper sample volume to be inspected. Only simple action is required to set the capillary tube into the holder.

lAlarm lamp informs user of abnormalities. Alarm lamp signals either abnormal value or situations such as burned out of the bulb, bilirubin concentration of 30mg/d£ or more, or high hemolysis of 250mg/d£ or more.

iFlexible power source Power requirement is flexible, from 100 to 240 V A C .

lEasy lamp replacement Exchange procedure of the lamp is simplicity itself.

* - h -tf u m & fco m m m mm <D mm i z x *) mtt a*±

± . ^ ^ , V # l t o ^ - ; e ^ n K > ^ s 2 5 0 r n g / d f M _ h V ^ - ^ t i ^ ^ ± #

Page 2: BR-5014lab.ir/userfiles/Shopping_ItemPdf/Pdf_10731_0892.pdf · DUAL WAVELENGTH TOTAL BILIRUBIN METER BR-501 Mostsuita&fefor jaundice analysis ofneonates. lAuto-zero function Advanced

E l DUAL WAVELENGTH TOTAL BILIRUBIN METER CO S jBSatSI^UJUtfvaCH BR-501

©LED alarm display ©Digital display ©0-ADJ Auto-0 button ©Scale knob ©Checked value (for memory) ©Check filter knob ©Capillary tube holder ©Serum gauge

© ^ - A f f l L E D ©LEDg|7JT§5

©7 . ^ - ; U , >7= © ^ i ^ f i K t B i l f f l )

0)*v¥:?v-3L3.-ymb?-

SPECIFICATIONS: ft m Filters 461 nm & 551 nm 7 461 nm, 551 nm Measurement range 0 to 30 mg/dfi (total bilirubin) -M ffl 0~30mg/dfi (1® tf 'J ;u t*» Correcting hemolysis 0 to 250 mg/dfi HbCV. m m m IE 0~250mg/dfi HbCV. Measuring accuracy ±5% M a ±5% Sample volume 1 capillary (whole blood) 0k /J\f > 7" % i B B l * ( £ J t L ) Alarm display 3-1/2,7-segment red LED m §§ 7 '>^W-1 /2 t f i LED Sample container Hematocrit capillary tube (heparinized) m B / \ h^«B(^/ , t |>i>MJi) Light source 6V, 1.5A tungsten lamp it » 6V, 1.5A ^ > ^ X f > 7 > 7 ' Photocell Sillicon photocell -> U =i > * * T 4 Power supply 100 - 240 VAC 50/60HZ, 35W m 100-240VAC 50/60Hz, 35W Dimensions 270mm(W)X220mm(D)X1 f0mm(H) 270mm (W) X220mm (D) X1 i 0mm (H) Weight Net 2.7kg (main body) M IEP*2.7kg(*f*)

STANDARD ACCESSORIES m mm& Bilirubin standard iviai m m m 1 * Capillary tube (heparinized) 1 vial (100 pes) ( / \ / \ - i ^ -MID 1^-^(100*) Capillary tube (plain) 1 vial (100 pes) m s (7" - > ) 1<ir-7x(100*) Tap seal 1pc % a B ffl M" x 1t t Spare lamp 1pc % y 7° H i Spare fused A) 2pcs t i - X ( 1 A ) 2f@ Dust cover 1pc X h * A — 1tt AC power cord 1pc - K 1 * Operation manual 1copy M ffi IK E 1 * Hffl

" ^ T e c h n i c a l specifications a n d / o r appearance are subject to change without any pr ior notice.

MANUF.

CO., LTD. J A P A N

URL http://www.apel.co.jp

I§7"\°L mmm^mmmm^ HB3XOOOO6

Distributor

No.BR51- l -CAT-304