80
Brad Gaugh November 29, 2010 1

Brad Gaugh November 29, 2010 1. Building Background Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Embed Size (px)

Citation preview

Page 1: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Brad GaughNovember 29, 2010

1

Page 2: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Building Background Lighting Spaces

◦ Façade◦ Lobby◦ Auxiliary Gymnasium◦ Weight and Fitness Room

2

Page 3: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Occupant

Building type

Usage

Harford Community CollegeFighting Owls

Athletic Facility

Division III NCAA basketballLocal Community indoor activitiesWeight and Fitness RoomSwimming Complex

Susquehanna Center

3

Page 4: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Location

Size

Cost

Construction Dates

Delivery Method

Architect

Lighting Consultants

Bel Air, Marylandlatitude = 39.56°N, longitude = 76.28°W

110,000 ft2

$28 million

April 2011 – August 2012

Design-Bid-Build

Hord Coplan Macht

Dunlop Lighting Design

Susquehanna Center

4

Page 5: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

N

5

Page 6: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Existing Building

Addition

N

Thomas Run Road

Main Entry Point

Road Entrance

Road Entrance

6

Page 7: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gym

Lobby

Weight & Fitness

Facade

Facade

Main Entry Point

N

7

Page 8: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

General Lighting Design Concepts

•Emphasize Game Type Atmosphere (Excitement, Intrigue, Festive, Cheerful)

•Provide Uniformity for Task Oriented Spaces

•Exhibit High Quality Facility

Susquehanna Center

8

Page 9: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Facade Floor Plan

Main EntryCovered Sidewalk

N

9

Page 10: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Facade Materials

10

Page 11: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Facade Lighting Design Concepts

Schematic #1 – Intrigue

•Create Visual Curiosity

•Develop Points of Interest

•Highlight Travel to Entrance

11

Page 12: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #1

12

Page 13: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #1

13

Page 14: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #1Highlight Shade

14

Page 15: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #1Wall Emphasis

15

Page 16: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #1Sidewalk Illumination

16

Page 17: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #1Back Lighting of Sign

17

Page 18: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #1Visual Curiousity

18

Page 19: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #1Equipment

19

Page 20: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Facade Lighting Design Concepts

Schematic #2 – The Nest

•Floating Roof

•Structure = Twigs of Nest

•Visual Curiosity

•Emphasize Travel to Entrance

20

Page 21: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #2

21

Page 22: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #2Back Lighting of Sign

22

Page 23: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #2Visual Curiosity Top of Nest

23

Page 24: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #2Visual Curiosity Twigs of Nest

24

Page 25: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #2Wall Emphasis

25

Page 26: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #2Sidewalk Illumination

26

Page 27: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #2Equipment

27

Page 28: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Facade Lighting Design Concepts

Schematic #3 – Game Day

• Inspiration Bryce Jordan Center Penn State

• Visual Interest Using Team Colors

• Create Visual Curiosity

• Highlight Travel to Entrance

28

Page 29: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #3

29

Page 30: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #3Color Lighting of Shades

30

Page 31: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #3Wall Emphasis

31

Page 32: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #3Sidewalk Illumination

32

Page 33: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #3Sign Illumination

33

Page 34: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #3Color Changing Illumination

34

Page 35: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #3Color Changing Illumination

35

Page 36: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #3Color Changing Illumination

36

Page 37: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Schematic Design #3Equipment

37

Page 38: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Lobby

Main Entry Point 38

Page 39: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Lobby Floor Plan

Wavy Pendants

• Pendants alternate in the Light Blue and Navy Blue colors

39

Page 40: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Lobby Materials

40

Page 41: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Lobby Lighting Design Concepts

Lighting to an Impression - Festive

•Provide bright non-uniform Lighting Mode

•Place emphasis on Points of Interest

•Utilize Movement of Light – Sparkle or Pulsate

41

Page 42: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Lobby Schematic DesignLobby Schematic Design 42

Page 43: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Lobby Schematic DesignDisplay Case

43

Page 44: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Lobby Schematic DesignHonorary Plaque

44

Page 45: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Lobby Schematic DesignRandom Slow Pulsating Fixture

45

Page 46: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Lobby Schematic DesignRandom Slow Pulsating Fixture

46

Page 47: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Lobby Schematic DesignRandom Slow Pulsating Fixture

47

Page 48: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Lobby Schematic DesignEquipment

48

Page 49: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Lobby Lighting Design Issues

Light interaction with Perforated Aluminum

•Stream Lines of Light

49

Page 50: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Lobby Schematic DesignAlternate Solution Wall Mounted

50

Page 51: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gym

N

51

Page 52: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gymnasium Floor Plan

52

Page 53: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gymnasium Section

53

Page 54: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gymnasium Materials

54

Page 55: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gymnasium Lighting Design Concepts

Lighting For an Task

•Provide adequate Illuminance

•Supply sufficient Uniformity at Task Plane

•Bring Daylight into space

•Integrate between Electric Light and Daylight

55

Page 56: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gym Schematic Design

56

Page 57: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gym Schematic DesignElectrical Lighting

57

Page 58: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gym Schematic DesignDaylighting with Skylights

58

Page 59: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gym Schematic DesignIntegration between Electric Light and Daylight

59

Page 60: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gym Schematic DesignEquipment

60

Page 61: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gymnasium Skylight Design

61

Page 62: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gymnasium Skylight Design

62

Page 63: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gymnasium Skylight Design

63

Page 64: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gymnasium Lighting Design Issues

Direct and Reflected Glare from Skylights

64

Page 65: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Auxiliary Gymnasium Lighting Design Issues

Direct and Reflected Glare from Skylights – Solution Electronic Shade Devices

65

Page 66: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Weight and Fitness

N

66

Page 67: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Weight & Fitness Floor Plan

67

Page 68: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Weight & Fitness Section and Materials

68

Page 69: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Weight & Fitness Lighting Design Concepts

Lighting For an Task

•Provide adequate Illuminance

•Supply sufficient Uniformity at Task Plane

•Bring Daylight into space

•Integrate between Electric Light and Daylight

69

Page 70: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Weight & Fitness Schematic Design

70

Page 71: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Weight & Fitness Schematic DesignLower Ceiling Down Lighting

71

Page 72: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Weight & Fitness Schematic DesignIndirect Lighting in High Exposed Ceiling

72

Page 73: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Weight & Fitness Schematic DesignDirect Daylight from North Facade

73

Page 74: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Weight & Fitness Schematic DesignIntegration between Electric Light and Daylight

74

Page 75: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Weight & Fitness Schematic DesignMid-Ceiling Down Lighting

75

Page 76: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Weight & Fitness Schematic DesignMid-Ceiling Down Lighting

76

Page 77: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Weight & Fitness Schematic DesignEquipment

77

Page 78: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Connecting the DOTS . . .

General Lighting Design Concepts

•Emphasize Game Type Atmosphere (Excitement, Intrigue, Festive, Cheerful)

•Exhibit High Quality Facility

78

Page 79: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Connecting the DOTS . . .

General Lighting Design Concepts

• Provide Uniformity for Task Oriented Spaces

79

Page 80: Brad Gaugh November 29, 2010 1.  Building Background  Lighting Spaces ◦ Façade ◦ Lobby ◦ Auxiliary Gymnasium ◦ Weight and Fitness Room 2

Brad GaughNovember 29, 2010

80