9
SPB DATA INFORMATION

Brochure Grundfos Submersible pumps - Solar Solved … - Operating range: from 0.3 to 4,5 m3/h with head of up to 240 m. - Liquid quality requirements: - Liquid temperature range:

Embed Size (px)

Citation preview

Page 1: Brochure Grundfos Submersible pumps - Solar Solved … - Operating range: from 0.3 to 4,5 m3/h with head of up to 240 m. - Liquid quality requirements: - Liquid temperature range:

SPBDATA INFORMATION

Page 2: Brochure Grundfos Submersible pumps - Solar Solved … - Operating range: from 0.3 to 4,5 m3/h with head of up to 240 m. - Liquid quality requirements: - Liquid temperature range:

1

SP-B

GENERAL DATAApplications

Submerged electric pump for 4” wells or larger, capable of generating a broad range of flow rates and heads. These units have a very extensive range of applications for lifting, distribution and pressurisation in civil and industrial water systems, filling of pressure vessels and tanks, fire-fighting and washing installations, and irrigation systems.

Pump construction features

Multistage centrifugal type with radial or semiaxial impellers. Directly coupled pump and motor with rigid coupling. Technopolymer impellers with stainless steel wear parts, functioning on floating clearance rings made of synthetic low abrasion material with technopolymer diffusers that impart significant wear resistance to the pump. Pump liner, shaft and coupling, filter and cable cover in stainless steel.Base support and head in technopolymer with steel check valve incorporated in head.

Motor construction characteristics

Submerged asynchronous two-pole motor made of AISI 304 stainless steel. For the parts in contact with the water. Squirrel cage rotor mounted on self-centring thrust block designed to withstand significant axial loads. Cooling of the thrust bearing and the bushings is provided by water, thereby eliminating the risk of oil contamination. Canned-type stator in an airtight casing made of stainless steel AISI 304L.

Flanging to NEMA – 4”Protection rating: IP68Heat insulation class: FInput voltage: single phase 220-230 V / 50Hz

three-phase 400 V / 50Hz

Supply

Control box (for single phase version) and motor must be ordered separately.

Page 3: Brochure Grundfos Submersible pumps - Solar Solved … - Operating range: from 0.3 to 4,5 m3/h with head of up to 240 m. - Liquid quality requirements: - Liquid temperature range:

2

from 0.3 to 4,5 m3/h with head of up to 240 m.- Operating range:

- Liquid quality requirements:

- Liquid temperature range:

clean, free of solid or abrasive contaminants, chemically neutral,

close to the properties of water.

from 0°C to +40°C

- Maximum permissible sand quantity: 120 gr/m3

- Installation:

- N° starts / hour:

- Cooling flow:

in 4” wells or larger, tanks and cisterns, vertical position.

max. 20 starts per hour

1.5m/sec.

- For the single-phase version the HS CONTROL BOX can be supplied on request to obtained increased starting torque.

TECHNICAL DATA

SP-B

49

18

57

69

7

58

98

6

55

42

54

4

3

39

271

192

191

270

117

No. PART*

BASE SUPPORT

IMPELLER

DIFFUSER

SHAFT WITH COUPLING

IMPELLERS LOCKING NUT

CABLE SHEATH

STRAINER

VALVE

MOTOR

SPACER

SUPPORT

INTERMEDIATE BUSH

PUMP LINER

DIFFUSER BODY

HEAD

FRONT THRUST RING

REAR THRUST RING

TOP SHAFT GUIDE BUSH

INTERMEDIATE SHAFT GUIDE BUSH

TECHNOPOLYMER A

TECHNOPOLYMER A

STAINLESS STEEL

STAINLESS STEEL

TECHNOPOLYMER A

TECHNOPOLYMER A

TECHNOPOLYMER A

TECHNOPOLYMER A

SYNTHETIC ABRASION-PROOF MATERIAL

SYNTHETIC ABRASION-PROOF MATERIAL

RUBBER

SYNTHETIC ABRASION-PROOF MATERIAL

TECHNOPOLYMER A with adjustment rings in AISI304 STAINLESS STEEL X5CrNi1810 – UNI 6900/71

AISI 304 STAINLESS STEEL X5CrNi1810 – UNI 6900/71

AISI 304 STAINLESS STEEL X5CrNi1810 – UNI 6900/71

AISI 304 STAINLESS STEEL X5CrNi1810 – UNI 6900/71AISI 304 STAINLESS STEEL X5CrNi1810 – UNI 6900/71

AISI 304 STAINLESS STEEL X5CrNi1810 – UNI 6900/71AISI 304 STAINLESS STEEL X5CrNi1810 – UNI 6900/71

3

4

6

7

18

39

42

49

54

55

57

58

69

98

117

191

192

270

271

MATERIAL

* In contact with liquid.

Page 4: Brochure Grundfos Submersible pumps - Solar Solved … - Operating range: from 0.3 to 4,5 m3/h with head of up to 240 m. - Liquid quality requirements: - Liquid temperature range:

3

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

SP-BA Liquid temperature range: from 0°C to +40°C

Ø(mm)

HEIGHT H

single-phase single-phasethree-phase three-phase

DNMH

PACK DIMENSIONS (mm)

L/A L/B

GROSS WEIGHT KgVOLUMEm3MODEL

SP-BA-8 SP-BA-12SP-BA-18

97

97

97

559

659

808

-

638

779

1” 1/4 G

1” 1/4 G

1” 1/4 G

110

110

110

110

110

110

770

770

910

0,010

0,010

0,011

11,4

13

15,2

-

12

13,9

ZAR RAND NETT PRICE EXCLUDING VAT

SP-BA-25SP-BA-36

97

97

969

1295

948

1221

1” 1/4 G

1” 1/4 G

110

120

110

120

1080

1590

0,013

0,023

16

21,9

16,2

19,2

0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 Q m3/h0

40

80

120

160

200

240

280

320

Hm

0

400

800

1200

1600

2000

2400

2800

PkPa

0 5 10 15 20 25 Q l/min

0 0,1 0,2 0,3 0,4 Q l/s

0

200

400

600

800

1000

H ft

0 1 2 3 4 5 6 7 Q US gpm0 1 2 3 4 5 Q IMP gpm

SP-BA-18

SP-BA-25

SP-BA-36

0 1,6 Q m3/h0,2 0,4 0,6 0,8 1 1,2 1,40

10

20

30

W

0

20

30

40

P η%

P2

η Eta

114,8 109,3 99,8 84 60,3 30,8

159,4 151,8 138,7 116,5 83,7 42,7

229,5 218,6 200 167,8 120,6 61,6

0 0,3 0,6 0,9 1,2 1,5

0PART NUMBER kWMODEL

HYDRAULIC DATA (n ∼ 2850 1/min)

H

(m)

Qm3/hl/min

SP-BA-18SP-BA-25 SP-BA-36

98717130

98717141

98717142

0,55

0,75

1,1

5 10 15 20 25

Page 5: Brochure Grundfos Submersible pumps - Solar Solved … - Operating range: from 0.3 to 4,5 m3/h with head of up to 240 m. - Liquid quality requirements: - Liquid temperature range:

4

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

SP-BBLiquid temperature range: from 0°C to +40°C

Ø(mm)

HEIGHT H

single-phase single-phase three-phase three-phase

DNMMODELH (M/T)

PACK DIMENSIONS

(mm) L/BL/A

GROSS WEIGHT KgVOLUME(M/T)

m3

SP-BB-5 SP-BB-8 SP-BB-12SP-BB-16

97

97

97

97

512

599

718

829

578

689

808

1” 1/4 G

1” 1/4 G

1” 1/4 G

1” 1/4 G

110

110

110

110

110

110

110

110

770

770

770

1080/910

0,010

0,010

0,010

0,013/0,010

11,1

12,5

14,4

16,3

11,5

12

15,1

0 0,4 0,8 1,2 1,6 2 2,4 Q m3/h0

40

80

120

160

200

240

280

Hm

0

400

800

1200

1600

2000

2400

1400

PkPa

0 5 10 15 20 25 30 35 40 Q l/min

0 0,1 0,2 0,3 0,4 0,5 0,6 Q l/s

0

100

200

300

400

500

600

700

800

900

H ft

0 1 2 3 4 5 6 7 8 9 10 Q US gpm0 1 2 3 4 5 6 7 8 Q IMP gpm

SP-BB-5

SP-BB-8

SP-BB-12

SP-BB-16

SP-BB-24

0 Q m3/h0,4 0,8 1,2 1,5 2 2,410

20

30

40

W

10

20

30

40

P η%

P2

ZAR RAND NETT PRICE EXCLUDING VAT

η Eta

31 30 28,6 26 22,6 19 14,8 10

49,6 47,8 45,8 41,5 36,2 30,6 23,7 16

74,4 71,8 68,6 62,3 54,4 45,8 35,5 24

99,2 95,7 91,5 83 72,5 61 47,4 32

148,8 143,5 137,3 124,6 108,7 91,7 71 48

0 0,6 0,9 1,2 1,5 1,8 2,1 2,4

0PART NUMBER kWMODEL

HYDRAULIC DATA (n ∼ 2850 1/min)

H

(m)

Qm3/hl/min

SP-BB-5SP-BB-8 SP-BB-12 SP-BB-16 SP-BB-24

98717143

98717144

98717145

98717146

98717147

0,37

0,37

0,55

0,75

1,1

10 15 20 25 30 35 40

Page 6: Brochure Grundfos Submersible pumps - Solar Solved … - Operating range: from 0.3 to 4,5 m3/h with head of up to 240 m. - Liquid quality requirements: - Liquid temperature range:

5

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

SP-BCLiquid temperature range: from 0°C to +40°C

Ø(mm)

HEIGHT H

single-phase single-phase three-phase three-phase

DNMH

PACK DIMENSIONS

(mm) L/BL/A

GROSS WEIGHT KgVOLUMEm3MODEL

SP-BC-6 SP-BC-9 SP-BC-13 SP-BC-19

97

97

97

97

614

741

891

1160

593

711

871

1086

1” 1/4 G

1” 1/4 G

1” 1/4 G

1” 1/4 G

110

110

110

120

110

110

110

120

770

910

1080

1240

0,010

0,011

0,013

0,018

12,6

14,6

15,5

18,5

11,5

13,2

15,4

17,8

0 0,8 1,6 2,4 3,2 4 Q m3/h0

40

80

120

160

200

240

280

Hm

0

400

800

1200

1600

2000

2400

2800

PkPa

0 10 20 30 40 50 60 70 Q l/min

0 0,2 0,4 0,6 0,8 1 1,2 Q l/s

0

100

200

300

400

600

700

800

900

1000

H ft

0 2 4 6 8 10 12 14 16 18 Q US gpm0 2 4 6 8 10 12 14 Q IMP gpm

SP-BC-6

SP-BC-9

SP-BC-13

SP-BC-19

0 Q m3/h0,8 1,6 2,4 3,2 420

30

40

50

W

20

30

40

50

P η%

P2

ZAR RAND NETT PRICE EXCLUDING VAT

η Eta

33 31,8 30,7 29,4 27,5 26,4 22,7 18,5 13,2

49,5 47,7 46 44 41,5 39,6 34 27,7 19,8

71,5 68,9 66,4 63,7 60,5 57,2 49,2 40 28,6

104,5 100,7 97 93 87,8 83,6 71,8 58,5 41,8

PART NUMBER kWMODEL

HYDRAULIC DATA (n ∼ 2850 1/min)

H(m)

Qm3/hl/min

SP-BC-6 SP-BC-9 SP-BC-13SP-BC-19

98717148

987171499871715098717151

0,37

0,55

0,75

1,1

0 1,2 1,5 1,8 2,1 2,4 3 3,6 4,2

0 20 25 30 35 40 50 60 70

Page 7: Brochure Grundfos Submersible pumps - Solar Solved … - Operating range: from 0.3 to 4,5 m3/h with head of up to 240 m. - Liquid quality requirements: - Liquid temperature range:

6

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

SP-BDLiquid temperature range: from 0°C to +40°C

Ø(mm)

HEIGHT H

single-phase single-phasethree-phase three-phase

DNMPACK DIMENSIONS (mm)

HL/A L/B

GROSS WEIGHT KgVOLUME

m3MODEL

SP-BD-4SP-BD-6 SP-BD-8 SP-BD-13

97

97

97

97

549

643

729

965

528

614

708

891

1” 1/4 G

1” 1/4 G

1” 1/4 G

1” 1/4 G

110

110

110

110

110

110

110

110

770

770

910

1080

0,010

0,010

0,011

0,013

12,2

14

15,5

17

11,2

12,7

14,3

16,6

0 1 2 3 4 5 6 Q m3/h0

40

80

120

160

200

240

280

Hm

0

400

800

1200

1600

2000

2400

2800

PkPa

0 10 20 30 40 50 60 70 80 90 100 Q l/min

0 0,4 0,8 1,2 1,6 Q l/s

0

100

200

300

400

500

600

700

800

900

H ft

0 4 8 12 16 20 24 Q US gpm0 4 8 12 16 20 Q IMP gpm

SP-BD-4

SP-BD-6SP-BD-8

SP-BD-13

0 Q m3/h1 2 3 4 5 640

50

60

70

80

W

30

40

50

60

70

P η%

P2

ZAR RAND NETT PRICE EXCLUDING VAT

η Eta

24 23 22,5 22 21,8 19,9 18 16,2 11,2

36 34,5 33,7 33 31,5 29,8 27 24,3 16,8

48 46 45 44 42 40 36 32,5 22,4

78 74,7 73,2 71,5 68,3 64,6 59 52,6 36,4

PART NUMBER kWMODEL

HYDRAULIC DATA (n ∼ 2850 1/min)

H(m)

Qm3/hl/min

SP-BD-4 SP-BD-6 SP-BD-8SP-BD-13

98717152

987171539871715498717155

0,37

0,55

0,75

1,1

0 1,8 2,1 2,4 3 3,6 4,2 4,8 6

30 35 40 50 60 70 80 1000

Page 8: Brochure Grundfos Submersible pumps - Solar Solved … - Operating range: from 0.3 to 4,5 m3/h with head of up to 240 m. - Liquid quality requirements: - Liquid temperature range:

rs

s

vw

No. PART*

SHAFT

SHAFT SEAL

MOTOR SLEEVE

RADIAL BEARING

AXIAL BEARING

RUBBER PARTS

MATERIAL

EN 1.4057

EN 1.4301

CERAMIC/CARBON

CERAMIC

NBR

1

2

3

5

6

NBR

PART NUMBER Voltage KW

96024858 230V 0.37kW96024941 230V 0.56kW96024861 230V 0.75kW96024863 230V 1.1kW96024942 230V 1.5kW

7

PART NUMBER Voltage KW

96024934 400V 0.37kW96024859 400V 0.56kW96024860 400V 0.75kW96024862 400V 1.1kW96024864 400V 1.5kW

MS 402 MOTORS

Material specification for MS motor

ZAR RAND NETT PRICE EXCLUDING VAT

Page 9: Brochure Grundfos Submersible pumps - Solar Solved … - Operating range: from 0.3 to 4,5 m3/h with head of up to 240 m. - Liquid quality requirements: - Liquid temperature range:

8

Ultra Voltage Range• 230V Starter• 230V Protection• 400V Protection

220V Ultra Starter• The 220V motor Starter provides the required interface to start a 220V motor.• Run Capacitor defer on each size.• Capacitor size is included on the cover•

Ultra Protection Features 230V (up to 1.5kW) and 400 (up to 1.5kW)

1. Self-diagnosis upon start-up (indication of the frequency).2. Normal operation (indication of the absorbed current).3. Situation of dry operation/low load (display of SB blinking).4. Stand-by for restoring of level (display of SB, load disconnected).5. Final lack of water, (display of UL , load disconnected)6. Overload in progress (display of the absorbed current blinking).7. Overload alarm (display of the OL blinking, load disconnected).8. After having eliminated any anomalies, Ultra may be reset by putting the on/off switch to off

and then on again.

PART NUMBER Voltage KW98642295 230V 0.37kW98642294Ultra Protection Box 230V 0.56kW98642293Ultra Protection Box 230V 0.75kW98642290Ultra Protection Box 230V 1.1kW98642253Ultra Protection Box 230V 1.5kW

PART NUMBER Voltage KW

98387478 400V 0.37kW98387478 400V 0.56kW98387478 400V 0.75kW98387478 400V 1.1kW98387478 400V 1.5kW

PART NUMBER KW

98642763 0.37kW98441458 0.56kW98441459 0.75kW98441460 1.1kW98441461 1.5kW

Voltage230V230V230V230V230V

Ultra Starter BoxUltra Starter BoxUltra Starter BoxUltra Starter Box

ULTRA PROTECTION BOX

Ultra Protection BoxUltra Protection BoxUltra Protection BoxUltra Protection Box

ULTRA PROTECTION BOX

Ultra Starter Box

Ultra Starter Box

Ultra Protection Box

Ultra Protection Box

ZAR RAND NETT PRICE EXCLUDING VAT

Reset Button for overload