Building Codes Intended to protect the public by establishing minimum standards of building safety.

Building Codes Intended to protect the public by establishing minimum standards of building safety

Embed Size (px)

Citation preview

Page 1: Building Codes Intended to protect the public by establishing minimum standards of building safety

Building Codes

Intended to protect the public by establishing minimum standards of

building safety.

Page 2: Building Codes Intended to protect the public by establishing minimum standards of building safety

Old National CodesOld National Codes

ICBO--Uniform Building Code --UBC written by International Conference of Building Officials

SBCCI—Standard Building Code—SBC written by Southern Building Code Congress International

BOCAI--Building Officials and Code Administrators International

CABO--Council of American Building Officials

Page 3: Building Codes Intended to protect the public by establishing minimum standards of building safety

International Building Code (IBC)

International Building Code (IBC)

IRC---written by ICC an agency formed from the National Code makers: BOCAI, SBCCI, and ICBO (CABO).

Page 4: Building Codes Intended to protect the public by establishing minimum standards of building safety

Other Additional CodesOther Additional Codes

Each publish guidelines for minimum property standards for residential construction.

HUD—Department of Housing and Urban Development

FHA--Federal Housing AuthorityADA--Americans with Disabilities Act

Page 5: Building Codes Intended to protect the public by establishing minimum standards of building safety

Choosing the Right CodeChoosing the Right CodeEach municipality adopt all or portions of a code. This could be

a state, national or International codeThe architect or engineer are responsible for conforming to and

ensuring that the structure complies with all required codes.Major codes are divided into sections that specify regulations

covering:Fire and life SafetyStructuralMechanical/PlumbingElectrical

Page 6: Building Codes Intended to protect the public by establishing minimum standards of building safety

OLD Building Code MapOLD Building Code Map

Page 7: Building Codes Intended to protect the public by establishing minimum standards of building safety

Habitable SpaceHabitable Space

Used for sleeping, living, cooking, or dining purposes.

Non Habitable Spaceclosetspantriesbathshallwaysutility roomsstorage and garages

Page 8: Building Codes Intended to protect the public by establishing minimum standards of building safety

Doors RequirementsDoors Requirements

One door 3’-0” (36”) wide and 6’-8” high, usually the entry door

Egress--term used in most building codes to specify areas of access or exits.

Page 9: Building Codes Intended to protect the public by establishing minimum standards of building safety

Windows RequirementsWindows RequirementsEgress below 4th floor

Minimum height size 24”50% must be operationalSill height maximum 44”

Page 10: Building Codes Intended to protect the public by establishing minimum standards of building safety

HallsHalls

Standard (minimum) 36” wideSome cases halls are laid out to be 42” wide,

usually in larger homes where extra space can be justified.

Page 11: Building Codes Intended to protect the public by establishing minimum standards of building safety

StairsStairs

Width--36” min, sometimes 42”Headroom--6’-8” main stairsHeadroom—6’-4” basementCommon rise height

7”-7 1/2” (Max. 7 ¾”)Common tread width

10”-10 1/2” (Min. 10”)

IRC Max

Common

Page 12: Building Codes Intended to protect the public by establishing minimum standards of building safety

Placement of doors at Stairways

Placement of doors at StairwaysLanding must be as long as stairs is wide

Door not to swing over stairsFirst step not to exceed 7 ½” from floor

Page 13: Building Codes Intended to protect the public by establishing minimum standards of building safety

Wall Placement over StairsWall Placement over StairsWall and Floor must not extend into Minimum

Headroom area

Page 14: Building Codes Intended to protect the public by establishing minimum standards of building safety

Room DimensionsRoom Dimensions

One room at least minimum of 120 sq ft (10’ x 12’)Other habitable rooms (except kitchen) to have a

minimum of 70 sq ft and not less than 7 feet in any direction.

Kitchens to be a minimum of 50 sq ft (CABO)

Page 15: Building Codes Intended to protect the public by establishing minimum standards of building safety

Ceiling Height of Habitable Rooms

Ceiling Height of Habitable Rooms

50% of room with more than 7’-0” ceilings

Page 16: Building Codes Intended to protect the public by establishing minimum standards of building safety

Bathroom Space Requirements

Bathroom Space Requirements

Codes may differ24” in front space (FHA)21” in front space (Text)

Page 17: Building Codes Intended to protect the public by establishing minimum standards of building safety

Bathroom Space Requirements

Bathroom Space Requirements

Water Closet (Toilet) Space

30” width space minimum or 15” from center to each side

36” width preferred or 18” from center to each side

15”MINIMUM

Page 18: Building Codes Intended to protect the public by establishing minimum standards of building safety

Bathroom and LaundryVenting RequirementsBathroom and LaundryVenting Requirements

Openable window or exhaust fan that can provide five air changes per hour.

Fans must be vented to outside air