Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
Building Management System solutions
Control all your building systems from one location That’s smartcontrol
Buildingmanagementsystem
ComAp’s BMS (Building Management System / Building Automation System) is a controller based solution that controls and monitors building electrical and mechanical equipment such as power system, fire system, air conditioning, lighting, heating, and ventilation.
The ComAp´s BMS also provides extensive history files and data logging and is capable of being controlled and monitored remotely via mobile phones, tablets or PCs.
Relay controlboard
ComAp BMS controller
Remote control & Cloud services
Control, monitoring and alarm management
system
Genset
Fire pumpsystem
Boost waterstation
Air conditioningcompressor
Temperaturesensor
+24 C
10:30
Lightsensor
Pressuresensor
What ComAp offers
> Effective monitoring > Targeting of energy consumption > Load shedding > Time scheduling/planning
> Different type of sensors to adjust requested environmental condition
> Follow customer condition over inbuilt PLC logic
> Plug & play expandability of control system
> Data collection system > After data evaluation easy backtracking of
problems and finding new improvements > All information in one place over
SCADA system > Possible remote alarms and remote control
Energy savingControl of the internal environment
Building maintenance1 2 3
How does it work?
Relay controlboard
ComAp BMS controller
Remote control & Cloud services
Control, monitoring and alarm management
system
Genset
Fire pumpsystem
Boost waterstation
Air conditioningcompressor
Temperaturesensor
+24 C
10:30
Lightsensor
Pressuresensor
Reference United KingdomLondon Data Center Various Screens were created in the InteliMonitor Software to allow all Breaker Sections of the Switchgear and the Generator Control System to be monitored from the InteliVision 17Touch Display, giving the operating technician all the information needed with regards to status and alarms. The required level of access was also easily configured to allow the operator control of individual ComAp controllers when required via password protected access.
The system was integrated into the plant BMS system to provide a continuous status of the condition of the plant, providing alarm indication of any fault on the system to the company headquarters.
Product overview
© ComAp. Features and specification are subject to change without prior notice. 2016-02/CPBEBMSS
Czech RepublicPhone: + 420 246 012 111Fax: + 420 266 316 647E-mail: [email protected]: www.comap.cz
ComAp a.s.
Manufacturer: Local distributor / partner:
InteliDrive Lite FPC > Modular engine controller designed for
diesel driven fire pump applications based on the NFPA 20 standard
> Automatic and manual starting sequence based on two batteries according to NFPA 20 standard
> Support of engines equipped with Electronic Control Unit (ECU) - J1939
> Engine speed control > 3 configurable analog inputs + 2 analog
inputs of battery voltage measurement
InteliGenNTC BaseBox > Complete integrated gen-set solution and
signal sharing via CAN bus – minimum external components needed
> Automatic synchronizing and power control (via speed governor or ECU)
> AMF function, Baseload, Import / Export, Peak shaving, Voltage and PF control (AVR)
> Generator measurement: U, I, Hz, kW, kVAr, kVA, PF, kWh, kVAhr
> Mains measurement: U, I, Hz, kW, kVAr, PF
InteliVision 17Touch > 17“ touchscreen display unit designed for
complete monitoring and control of building management system
> IP-65 NEMA 4 Aluminium die cast front bezel
> Two easy access front USB ports > Over and under voltage protection > Polarity protection > UL certified
Inteli IO8/8 Inteli AIN8 InternetBridge-NT WebSupervisor
InteliLite BMS > Control, monitoring and
protection system > Electric Motor control,
monitoring and protection
> All common ways to start asynchronous motor: direct, Y-D, SoftStarter starting
> Selectable protections alarm / shutdown
> Setpoints adjustable via keyboard or PC
> 3phase AC voltage and current measurements
> USB, RS485 or RS232, GSM /GPRS, ModBus communication
> Real time clock and event history log
> Automatic or manual start/stop of the motor
InteliDrive BMS > Control, monitoring and
protection system > Fully configurable 14 binary
inputs and 14 binary outputs and 8 analog inputs
> RS232, ModBus, Ethernet, Cellular communication
> Internal configurable PLC logic > Graphical screen with
possibilities of remote screen > Event and time stamp history
log for backtracking > Extension modules for
expandable number of IOs connected via CAN bus
> 3 level password protection > UL certified