11
Jaga Heating Products (UK) Ltd | www.jaga.co.uk T: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected] The perfect recessed heating system BUILT-IN

BuilT-in - Jaga · PDF fileBS H 135>185 B d h h H 80 08 ... Product code: BIWW Built-in ... 300 75/65/20 544 680 815 951 1087 1223 1359 1495 1631 1903 2174 2446 2718 2990 3262 3533

  • Upload
    buiphuc

  • View
    220

  • Download
    6

Embed Size (px)

Citation preview

Page 1: BuilT-in - Jaga · PDF fileBS H 135>185 B d h h H 80 08 ... Product code: BIWW Built-in ... 300 75/65/20 544 680 815 951 1087 1223 1359 1495 1631 1903 2174 2446 2718 2990 3262 3533

Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]

The perfect recessed heating systemBuilT-in

Page 2: BuilT-in - Jaga · PDF fileBS H 135>185 B d h h H 80 08 ... Product code: BIWW Built-in ... 300 75/65/20 544 680 815 951 1087 1223 1359 1495 1631 1903 2174 2446 2718 2990 3262 3533

Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]

255>

290

L110 75

BS

H

135>185

Bd

hh

H

08 LL 80110 75

65 65

50 135

1 2

345

1 2

345

d 38 20

2547

50

26

2.4

d

Ad

2.55

2550

60

50 37

60

50 37

24

d

Ad

2550

2.55

6.0

5.0 3.7

6.0

5.0 3.7

Example of Jaga Pro valve- to the wall or the floor

Product code: BIWW

Built-in

Dimensions in mm

Type D B d h1 h2

10 - 11 118 100 53 100 100

15 - 16 168 150 78 120 120

20 - 21 218 200 103 150 150

Connections

Built-in Wall is available in lengths from 400 to 3000mm

Dimensions

h1h2

H Hh1

h1h2

HD D D

B

d

B

d

B

d

Heat outputs are calculated on the given dimensions and with free outlet of 75% of dimension B. For other dimensions or grilles, correction factors have to be applied.

Correction factors free air flow

% air flow correction factor

75 1.00

60 0.96

50 0.92

40 0.84

30 0.66

Hydraulic connectionAll connections left or right are exchangeable

255>

290

L110 75

BS

H

135>185

Bd

hh

H

08 LL 80110 75

65 65

50 135

1 2

345

1 2

345

d 38 20

2547

50

26

2.4

d

Ad

2.55

2550

60

50 3760

50 37

24

d

Ad

2550

2.55

6.0

5.0 3.76.

05.0 3.7

Example of Jaga valve - to the wall

Page 3: BuilT-in - Jaga · PDF fileBS H 135>185 B d h h H 80 08 ... Product code: BIWW Built-in ... 300 75/65/20 544 680 815 951 1087 1223 1359 1495 1631 1903 2174 2446 2718 2990 3262 3533

Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]

Outputs in watts at 75/65/20°C & 55/45/20°C, in accordance with EN442

• Low-H20 heat exchanger

• Brackets

• Extended air vent 1/8”

• Drain plug 1/2”

Supplied as Standard

Outputs

Installation into a wall recess - Type 10

200 5691 4381 3071 2751 1441 0131 9711 8401 719 687 127 556 095 425 954 393 823 262 02/56/57 559 198 728 467 007 736 375 905 644 283 053 813 782 552 322 191 951 721 02/54/55

300 8742 3132 8412 2891 7181 2561 7841 2231 6511 199 909 628 347 166 875 694 314 033 02/56/57 0121 0311 9401 869 788 708 627 646 565 484 444 304 363 323 282 242 202 161 02/54/55

400 9882 6962 4052 1132 9112 6291 3371 1451 8431 6511 9501 369 768 077 476 875 284 583 02/56/57 7141 3231 9221 4311 0401 549 058 657 166 765 025 274 524 873 133 482 632 981 02/54/55

500 223 3103 8972 2852 7632 2512 7391 2271 6051 1921 4811 6701 869 168 357 646 835 034 02/56/57 8 1951 5841 9731 3721 7611 1601 559 948 247 636 485 035 774 424 173 813 562 212 02/54/55

600 53 6723 2403 8082 4752 0432 6012 2781 8361 4041 7821 0711 3501 639 918 207 585 864 02/56/57 10 8371 2261 6051 0931 5721 9511 3401 729 118 596 736 975 125 364 604 843 092 232 02/54/55

700 73 4943 5423 5992 6472 6942 6422 7991 7471 8941 3731 8421 3211 899 478 947 426 994 02/56/57 44 3681 9371 5161 1941 7631 2421 8111 499 968 647 386 126 955 794 534 373 113 842 02/54/55

900 4 3383 9553 6823 2103 8372 4642 0912 7191 3461 6051 9631 2321 5901 859 128 586 845 02/56/57 107 3602 5291 8871 0561 3151 5731 8321 0011 369 528 657 886 916 055 184 214 443 572 02/54/55

epyt htgnel thgieh edoc

01 040 020 .WWIB : EDOC GNIREDRO 01 epyt _ ssecer llaw a otni noitallatsnI

H L 400 500 600 700 800 900 1000 1200 14001100 1600 1800 2000 2200 2400 2600 2800 3000

code height length type

OrDEr CODE: BIWW 050 160 10(Example order code shown is for a 500mm high radiator, 1600mm long, type 10)

Installation into a wall recess - Twin Type 11

Supplied as Standard

code height length type

OrDEr CODE: BIWW 050 180 11(Example order code shown is for a 500mm high radiator, 1800mm long, type 11)

• Low-H20 Twin heat exchanger

• Brackets

• Extended air vent 1/8”

• Drain plug 1/2”

300 33 9313 5192 0962 6642 2422 8102 4971 9651 5431 3321 1211 9001 798 587 376 165 844 02/56/57 63 2161 4051 7931 9821 2811 4701 769 068 257 546 195 735 484 034 673 323 962 512 02/54/55

400 3 9353 6823 4303 1872 8252 5722 2202 0771 7151 0931 4621 8311 1101 588 857 236 605 02/56/57 792 8181 7961 6751 5541 3331 2121 1901 969 948 727 666 606 645 584 424 363 303 342 02/54/55

500 4 1883 4063 6233 9403 2772 5942 8122 0491 3661 5251 6831 7421 9011 079 238 396 455 02/56/57 158 5991 2681 9271 6951 3641 0331 7911 4601 139 897 237 566 895 235 564 993 233 662 02/54/55

600 3814 4883 6853 7823 8892 9862 0932 2902 3971 3461 4941 5431 5911 6401 698 747 895 02/56/57 4482 1512 8002 4681 1271 8751 4341 1921 7411 4001 168 987 717 646 475 205 034 953 782 02/54/55

700 2544 4314 6183 8943 0813 2682 4452 6222 8091 9471 0951 1341 2721 3111 459 597 636 02/56/57 4770 1922 8312 5891 2381 0861 7251 4731 2221 9601 619 048 467 786 116 435 854 283 503 02/54/55

900 2294 1754 9124 8683 6153 4613 3182 1642 0112 4391 8571 2851 6041 1321 5501 978 307 02/56/57 4725 5352 6632 7912 8202 9581 0961 1251 2531 3811 4101 039 548 067 676 295 705 324 833 02/54/55

epyt htgnel thgieh edoc

11 040 030 .WWIB : EDOC GNIREDRO 11 epyt _niwT ssecer llaw a otni noitallatsnI

H L 400 500 600 700 800 900 1000 1200 14001100 1600 1800 2000 2200 2400 2600 2800 3000

All dimensions are shown in millimetresOutput measured in accordance with EN442, at a water temperature of 75/65°C and a room temperature of 20°C (ΔT=50).

Page 4: BuilT-in - Jaga · PDF fileBS H 135>185 B d h h H 80 08 ... Product code: BIWW Built-in ... 300 75/65/20 544 680 815 951 1087 1223 1359 1495 1631 1903 2174 2446 2718 2990 3262 3533

Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]

Outputs in watts at 75/65/20°C & 55/45/20°C, in accordance with EN442

• Low-H20 heat exchanger

• Brackets

• Extended air vent 1/8”

• Drain plug 1/2”

Supplied as Standard

Outputs

Installation into a wall recess - Type 15

200 723 2503 4382 6162 8932 0812 2691 4471 6251 8031 9911 0901 189 278 367 456 545 634 02/56/57 0 3951 7841 1831 4721 8611 2601 659 058 347 736 485 135 874 524 273 913 562 212 02/54/55

300 4 5083 3353 2623 0992 8172 6442 4712 3091 1361 5941 9531 3221 7801 159 518 086 445 02/56/57 077 8991 5681 2371 9951 5641 2331 9911 6601 339 997 337 666 995 335 664 993 333 762 02/54/55

400 0934 7704 3673 0543 6313 2282 9052 5912 2881 5271 8651 1141 4521 8901 149 487 726 02/56/57 4704 8132 4612 9002 5581 0071 6451 1931 7321 2801 829 058 377 596 816 145 464 683 903 02/54/55

500 5584 8054 2614 5183 8643 1213 4772 8242 1802 7091 4371 1651 7831 4121 0401 768 496 02/56/57 2025 0852 8042 6322 4602 2981 0271 8451 6731 4021 2301 649 068 477 886 206 615 034 443 02/54/55

600 5225 2584 8744 5014 2373 9533 6892 2162 9322 3502 6681 9761 3941 6031 0211 339 647 02/56/57 8955 972 7062 1242 4322 8402 2681 6761 0941 3031 7111 4201 139 838 547 256 955 664 273 02/54/55 3

700 2255 7215 3374 8334 4493 0553 5513 1672 6632 9612 2791 5771 8751 0831 3811 689 987 02/56/57 6195 692 1772 3752 5732 7712 9791 1871 3851 5831 7811 8801 989 198 297 296 495 594 693 02/54/55 8

900 6395 2155 8805 4664 0424 6183 2933 8692 4452 2332 0212 8091 6961 4841 2721 0601 848 02/56/57 6360 23 5103 0082 4852 9632 4512 8391 3271 8051 2921 5811 7701 969 168 457 646 835 134 02/54/55 31

epyt htgnel thgieh edoc

51 040 020 .WWIB : EDOC GNIREDRO 51 epyt _ ssecer llaw a otni noitallatsnI

H L 400 500 600 700 800 900 1000 1200 14001100 1600 1800 2000 2200 2400 2600 2800 3000

code height length type

OrDEr CODE: BIWW 020 300 15(Example order code shown is for a 200mm high radiator, 3000mm long, type 15)

Installation into a wall recess - Twin Type 16

Supplied as Standard

code height length type

OrDEr CODE: BIWW 090 220 16(Example order code shown is for a 900mm high radiator, 2200mm long, type 16)

• Low-H20 Twin heat exchanger

• Brackets

• Extended air vent 1/8”

• Drain plug 1/2”

300 4414 8483 2553 6523 0692 4662 8632 2702 6771 8261 0841 2331 4811 6301 888 047 295 02/56/57 4440 0112 0791 9281 8861 8451 7041 6621 6211 589 448 477 307 336 365 294 224 253 182 02/54/55

400 0674 0244 0804 0473 0043 0603 0272 0832 0402 0781 0071 0351 0631 0911 0201 058 086 02/56/57 0015 9142 8522 7902 5391 4771 3161 2541 0921 9211 869 788 608 627 546 465 484 304 323 02/54/55

500 4135 5394 5554 6714 6973 6143 7303 7562 8722 8802 8981 8071 8151 9231 9311 949 957 02/56/57 4965 5962 6152 6332 6512 7791 7971 7161 8341 8521 8701 889 898 908 917 926 935 944 953 02/54/55

600 5385 8145 2005 5854 8614 1573 4333 8192 1052 2922 4802 6781 7661 9541 0521 2401 438 02/56/57 6252 592 7572 0652 3632 6612 9691 2771 5751 9731 2811 3801 589 688 887 986 195 294 493 02/54/55 4

700 8236 6785 4245 2794 0254 8604 6163 4613 2172 6842 0622 4302 8081 2851 6531 0311 409 02/56/57 6780 13 3892 0772 7552 4432 1312 8191 5071 2941 9721 2711 5601 959 258 647 936 335 624 02/54/55 96

900 9627 0576 0326 1175 2915 3764 4514 4363 5113 6582 6952 6332 7702 7181 8551 8921 8301 02/56/57 8877 3 3143 9613 5292 1862 8342 4912 0591 6071 3641 1431 9121 7901 579 358 237 906 784 02/54/55 657

epyt htgnel thgieh edoc

61 040 030 .WWIB : EDOC GNIREDRO 61 epyt _niwT ssecer llaw a otni noitallatsnI

H L 400 500 600 700 800 900 1000 1200 14001100 1600 1800 2000 2200 2400 2600 2800 3000

All dimensions are shown in millimetresOutput measured in accordance with EN442, at a water temperature of 75/65°C and a room temperature of 20°C (ΔT=50).

Page 5: BuilT-in - Jaga · PDF fileBS H 135>185 B d h h H 80 08 ... Product code: BIWW Built-in ... 300 75/65/20 544 680 815 951 1087 1223 1359 1495 1631 1903 2174 2446 2718 2990 3262 3533

Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]

Outputs in watts at 75/65/20°C & 55/45/20°C, in accordance with EN442

• Low-H20 heat exchanger

• Brackets

• Extended air vent 1/8”

• Drain plug 1/2”

Supplied as Standard

Outputs

Installation into a wall recess - Type 20

200 0924 3893 7763 0733 4603 8572 1542 5412 8381 5861 2351 9731 6221 2701 919 667 316 02/56/57 4596 9322 0902 0491 1971 2461 3941 3431 4911 5401 598 128 647 276 795 225 844 373 992 02/54/55

300 7335 6594 4754 3914 2183 1343 0503 8662 7822 7902 6091 5171 5251 4331 4411 359 267 02/56/57 8175 082 6162 9242 2422 5502 8681 2861 5941 8031 1211 8201 439 148 747 456 165 764 373 02/54/55 2

400 9416 0175 0725 1384 2934 3593 4153 4703 5362 6142 6912 6791 7571 7351 8131 8901 878 02/56/57 6588 23 2303 6182 9952 2832 6612 9491 3371 6151 9921 1911 3801 479 668 857 056 145 334 02/54/55 49

500 0976 5036 0285 5335 0584 5634 0883 5933 0192 8662 5242 3812 0491 8961 5541 3121 079 02/56/57 7275 3 7633 7213 6882 6462 5042 5612 4291 4861 3441 3231 3021 3801 269 248 227 206 184 02/54/55 608

600 2037 1876 9526 8375 6125 4964 3714 1563 0313 9682 8062 7432 6802 6281 5651 4031 3401 02/56/57 4287 3463 3833 3213 3682 3062 2432 2802 2281 2651 2341 1031 1711 1401 119 187 156 025 02/54/55 3904

700 8077 8517 7066 7506 6055 5594 5044 4583 4033 8203 3572 8742 2022 7291 2561 7731 1011 02/56/57 9528 0783 4953 7133 1403 4672 8842 1122 5391 9561 0251 2831 4421 5011 769 928 196 355 02/54/55 4146

900 0828 8867 7907 5056 4195 3235 1374 0414 8453 3523 7592 1662 6632 0702 4771 9741 3811 02/56/57 1788 6024 5093 5063 4033 4003 4072 3042 3012 2081 2561 2051 2531 2021 1501 109 157 106 02/54/55 6054

epyt htgnel thgieh edoc

02 040 020 .WWIB : EDOC GNIREDRO 02 epyt _ ssecer llaw a otni noitallatsnI

H L 400 500 600 700 800 900 1000 1200 14001100 1600 1800 2000 2200 2400 2600 2800 3000

code height length type

OrDEr CODE: BIWW 090 2000 20(Example order code shown is for a 900mm high radiator, 2000mm long, type 20)

Installation into a wall recess - Twin Type 21

Supplied as Standard

code height length type

OrDEr CODE: BIWW 050 220 21(Example order code shown is for a 500mm high radiator, 2200mm long, type 21)

• Low-H20 Twin heat exchanger

• Brackets

• Extended air vent 1/8”

• Drain plug 1/2”

300 4545 5605 5764 6824 6983 6053 7113 7272 8332 3412 8491 3571 8551 4631 9611 479 977 02/56/57 4485 672 7752 3932 9022 5202 1481 6561 3741 8821 5011 2101 029 828 637 446 255 064 863 02/54/55 1

400 7636 2195 8545 3005 8454 3904 8363 4813 9272 1052 4722 7402 9181 2951 4631 7311 019 02/56/57 6822 23 4992 0872 7652 3532 9312 5291 1171 7941 3821 6711 9601 369 558 947 146 535 824 02/54/55 08

500 0327 3176 7916 0865 4615 8464 1314 5163 8903 0482 2852 4232 6602 7081 9451 1921 3301 02/56/57 6477 3 6833 4413 2092 0662 8142 7712 5391 3961 1541 0331 9021 8801 869 648 527 506 484 02/54/55 628

600 0708 3947 7196 0436 4675 8815 1164 5304 8543 0713 2882 4952 6032 7102 9271 1441 3511 02/56/57 6468 4673 5943 6223 7592 8862 0242 1512 2881 3161 9741 4431 0121 6701 149 608 276 835 02/54/55 4033

700 6988 0628 5267 9896 4536 9175 3805 8444 2183 5943 7713 9582 2452 4222 6091 9851 1721 02/56/57 1359 2314 7383 2453 7423 2592 7562 1632 6602 1771 3261 6741 8231 1811 3301 588 837 095 02/54/55 7244

900 5501 2089 8409 4928 0457 6876 2306 8725 4254 7414 0773 3933 6103 9362 2622 5881 8051 02/56/57 01311 6 1684 4154 7614 9183 2743 5213 8772 1342 3802 0191 6371 2651 9831 5121 2401 868 496 02/54/55 5208

epyt htgnel thgieh edoc

12 040 030 .WWIB : EDOC GNIREDRO 12 epyt _niwT ssecer llaw a otni noitallatsnI

H L 400 500 600 700 800 900 1000 1200 14001100 1600 1800 2000 2200 2400 2600 2800 3000

All dimensions are shown in millimetresOutput measured in accordance with EN442, at a water temperature of 75/65°C and a room temperature of 20°C (ΔT=50).

Page 6: BuilT-in - Jaga · PDF fileBS H 135>185 B d h h H 80 08 ... Product code: BIWW Built-in ... 300 75/65/20 544 680 815 951 1087 1223 1359 1495 1631 1903 2174 2446 2718 2990 3262 3533

Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]

Thermostatic heads

DW

Chrome/ White

DC

Chrome

JA

White

JC

Silver

RM

remote Controlled

DS

Chrome/white remote sensor

Connection Sets

Connection to the wall - bottom of casing

Code Thermostatic head

COLO.PW2.DW.3... chrome / white

COLO.PW2.DC.3... chrome

COLO.PW2.JA.3... white 4

COLO.PW2.JC.3... silver

51

Two pipe

Jaga Pro valve

Thermostatic head of choice

Sleeve couplings M24

2 curves to the wall

Set 11 Jaga Pro valve

Kv max. 0.6

Connection to the floor

Jaga Pro valve

Thermostatic head of choice

Sleeve couplings M24

Set 12 Jaga Pro valve

Code Thermostatic head

COLO.PF2.DW.3... chrome / white

COLO.PF2.DC.3... chrome

COLO.PF2.JA.3... white 4

COLO.PF2.JC.3... silver

51

Two pipeKv max. 0.6

Universal valve set for connection to the wall or to the floor Kv max. 0.6

Set 26 Jaga Comap valve

Code Thermostatic head

COLO.CP2.DW.4... chrome / white

COLO.CP2.DC.4... chrome

COLO.CP2.JA.4... white 4

COLO.CP2.JC.4... silver

51

Two pipe

Jaga Comapthermostatic valve

Thermostatic head of choice

Sleeve couplings Eurocone 3/4”

Connection to the wall - Not for Type 06 Kv max. 0.6

Set 21 Jaga valve

Code Thermostatic head

COLO.JW2.DW.2... chrome / white

COLO.JW2.DC.2... chrome

COLO.JW2.JA.2... white 4

COLO.JW2.JC.2... silver

51

Two pipe

Jaga thermostatic valve

Thermostatic head of choice

Sleeve couplings M24

Angled lockshield

The order code of the connection set will be completed with the sleeve coupling code

Page 7: BuilT-in - Jaga · PDF fileBS H 135>185 B d h h H 80 08 ... Product code: BIWW Built-in ... 300 75/65/20 544 680 815 951 1087 1223 1359 1495 1631 1903 2174 2446 2718 2990 3262 3533

Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]

Connection to the floor Kv max. 0.6

Set 22 Jaga valve

Code Thermostatic head

COLO.JF2.DW.2... chrome / white

COLO.JF2.DC.2... chrome

COLO.JF2.JA.2... white 4

COLO.JF2.JC.2... silver5

1

Two pipe

Jaga thermostatic valve

Thermostatic head of choice

Sleeve couplings M24

Straight lockshield

Connection to the floor Kv max. 0.6

Set 23 Jaga valve

Code Thermostatic head

COLO.JW3.DW.2... chrome / white

COLO.JW3.DC.2... chrome

COLO.JW3.JA.2... white 4

COLO.JW3.JC.2... silver

51

Two pipe

Jaga thermostatic valve Thermostatic head of choice

Extension pipe

Sleeve couplings M24

H-piece angled

Connection to the floor Kv max. 0.6

Set 24 Jaga valve

Code Thermostatic head

COLO.JF3.DW.2... chrome / white

COLO.JF3.DC.2... chrome

COLO.JF3.JA.2... white 4

COLO.JF3.JC.2... silver

51

Two pipe

Extension pipe

Jaga thermostatic valve

Thermostatic head of choice

Sleeve couplings M24

H-piece straight

Thermostatic heads

DW

Chrome/ White

DC

Chrome

JA

White

JC

Silver

RM

remote Controlled

DS

Chrome/white remote sensor

Connection to the wall within the casing Kv max. 0.6

Jaga Type 6 thermostatic valve

Thermostatic head of choice

Sleeve couplings M24

Angled lockshield

Set 25 Jaga Type 6 valve

Code Thermostatic head

COLO.SW2.DW.3... chrome / white

COLO.SW2.DC.3... chrome

COLO.SW2.JA.3... white 4

COLO.SW2.JC.3... silver

51

Two pipe

The order code of the connection set will be completed with the sleeve coupling code

Page 8: BuilT-in - Jaga · PDF fileBS H 135>185 B d h h H 80 08 ... Product code: BIWW Built-in ... 300 75/65/20 544 680 815 951 1087 1223 1359 1495 1631 1903 2174 2446 2718 2990 3262 3533

Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]

For flexible steel or copper tube Ø 15mm

Code 5090.1120

Pro Key

Tool for easy mounting of the Jaga Pro valve.

Code Tube Ø

112 12/1

114 14/1

115 15/1

116 16/1

118 18/1

For Jaga Comap valve - Eurocone 3/4”

Code Tube Ø

612 12/2

614 14/2

616 16/2

617 17/2

618 18/2

615 15/2.5

619 16/1.5

620 20/2

For flexible steel or copper tubeFor synthetic or RPE/ALU tube

3/4”M 243/4”

For t

ube

12/2

onl

y

Sleeve Couplings

Code Tube Ø

314 14/2

316 16/2

326 16/2.2

318 18/2

Code Tube Ø

501 1/2”

503 3/8”

Steel tube for CHFor RPE/ALU tube

Code Tube Ø

110 10/1

112 12/1

114 14/1

115 15/1

116 16/1

118 18/1

For flexible steel or copper tube

1/2”

1/2”

1/2”

For t

ube

18/1

onl

y

For t

ube

15/1

onl

y

Code Tube Ø

212 12/2

214 14/2

219 16/1.5

216 16/2

217 17/2

218 18/2

For synthetic tube

1/2”

1/2”

1/2”

For Jaga valve - M24

Short Coupling - for Connection to the wall

Code Tube Ø

125 15/1

1/2"1/2”

Complete ordering code with sleeve couplings according to the material used and diameter of the tube. The correct type of sleeve coupling is determined by the ordering code of the connection set

Example: COLO. PW2.DW. 32. (insert relevant code from above)

Included in the price of the connection sets

Page 9: BuilT-in - Jaga · PDF fileBS H 135>185 B d h h H 80 08 ... Product code: BIWW Built-in ... 300 75/65/20 544 680 815 951 1087 1223 1359 1495 1631 1903 2174 2446 2718 2990 3262 3533

Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]

Average correction factors according to EN442 - 75/65/20°C

Tv Tl

90 20 0.62 0.68 0.74 0.80 0.87 0.93 1.00 1.07 1.14 1.21 1.28 1.36 1.43 1.50 24 0.52 0.58 0.64 0.70 0.76 0.83 0.89 0.96 1.03 1.10 1.17 1.24 1.31 1.38

85 20 0.56 0.62 0.68 0.74 0.80 0.87 0.93 1.00 1.07 1.14 1.21 1.28 1.36 24 0.47 0.52 0.58 0.64 0.70 0.76 0.83 0.89 0.96 1.03 1.10 1.17 1.24

80 20 0.50 0.56 0.62 0.68 0.74 0.80 0.87 0.93 1.00 1.07 1.14 1.21 24 0.41 0.47 0.52 0.58 0.64 0.70 0.76 0.83 0.89 0.96 1.03 1.10

75 20 0.44 0.50 0.56 0.62 0.68 0.74 0.80 0.87 0.93 1.00 1.07 24 0.36 0.41 0.47 0.52 0.58 0.64 0.70 0.76 0.83 0.89 0.96

70 20 0.39 0.44 0.50 0.56 0.62 0.68 0.74 0.80 0.87 0.93 24 0.31 0.36 0.41 0.47 0.52 0.58 0.64 0.70 0.76 0.83

65 20 0.34 0.39 0.44 0.50 0.56 0.62 0.68 0.74 0.80 24 0.26 0.31 0.36 0.41 0.47 0.52 0.58 0.64 0.70

60 20 0.29 0.34 0.39 0.44 0.50 0.56 0.62 0.68 24 0.21 0.26 0.31 0.36 0.41 0.47 0.52 0.58

55 20 0.24 0.29 0.34 0.39 0.44 0.50 0.56 24 0.17 0.21 0.26 0.31 0.36 0.41 0.47

50 20 0.19 0.24 0.29 0.34 0.39 0.44 24 0.13 0.17 0.21 0.26 0.31 0.36

45 20 0.15 0.19 0.24 0.29 0.34 24 0.09 0.13 0.17 0.21 0.26

40 20 0.11 0.15 0.19 0.24 24 0.06 0.09 0.13 0.17

35 20 0.05 0.08 0.12 24 0.03 0.06 0.09

30 20 0.04 0.08 24 0.00 0.03

Natural Correction factors

25 30 35 40 45 50 55 60 65 70 75 80 85Tr > 20

Insulation 20° 24°

excellent 45 55

good 65 75

average 85 95

poor 100 115

required output in Watts/m³

Average correction factors according to EN442 - 75/65/20°C

How to choose the right radiator?

Correction factors

Rapid estimation of heat lossesCalculate the volume of the room (L x W x H)and multiply this by the Watts/m³ fi gure given in the table below. Choose according to the level of insulation and the desired room temperature.

ExampleUse the table to determine the relevant correction factor with a water temperature of 80/60°c with a room temperature of 24°C.

The correction factor = 0.89

required output 1000 watts : 1000 divided by 0.89 = 1124 watts therefore search in this leafl et’s standard output table for a product with an output of at least 1124 watts. Alternatively use the “radiator Finder” search function on www.jaga.co.uk to identify all Jaga heating products with this required output.

Output calculated in accordance with EN442, at a water temperature of 75/65°C and a room temperature of 20°C (ΔT=50).

The indicated outputs with ΔT 50°c and ΔT 30°c are the exact outputs. ΔT 50°c outputs are measured in accordance with EN442 and ΔT 30°c outputs are calculated according to EN442.

An average correction factor is given in this table for outputs at other ΔT and is applicable for all dimensions.

KEYTv = fl ow temperature

Tr = return temperatureTl = desired air temperature

Page 10: BuilT-in - Jaga · PDF fileBS H 135>185 B d h h H 80 08 ... Product code: BIWW Built-in ... 300 75/65/20 544 680 815 951 1087 1223 1359 1495 1631 1903 2174 2446 2718 2990 3262 3533

Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]

H T› 10 11 15 16 20 21

200 5.4 --- 6.7 --- 8.3 ---

300 6.6 8.2 8.1 10.8 9.8 13.4

400 7.8 9.4 9.5 12.2 11.3 14.9

500 9.0 10.7 10.8 13.6 12.9 16.4

600 10.3 11.9 12.2 14.9 14.4 17.9

700 11.5 13.1 13.6 16.3 15.9 19.4

900 14.3 15.8 17.3 19.8 19.3 22.3

Weight in kg

Pressure drop type 10

1000100103 34 46 68 82 2

L = 150L = 70

L = 490L = 350

P P[bar]

P[kPa]

1000

100

800600

1

300

200

500400

8060

30

20

5040

1086

3

2

54

0.1

0.01

0.080.06

0.0001

0.03

0.02

0.050.04

0.0080.006

0.003

0.002

0.0050.004

0.0010.00080.0006

0.0003

0.0002

0.00050.0004

10

1

86

0.01

3

2

54

0.80.6

0.3

0.2

0.50.4

0.10.080.06

0.03

0.02

0.050.04

Water flow in kg/h

Pres

sure

dro

p in

mm

WC

Pressure drop type 11

L = 050

L = 280L = 150

1000100103 34 46 68 82 2

P P[bar]

P[kPa]

1000

100

800600

1

300

200

500400

8060

30

20

5040

1086

3

2

54

0.1

0.01

0.080.06

0.0001

0.03

0.02

0.050.04

0.0080.006

0.003

0.002

0.0050.004

0.0010.00080.0006

0.0003

0.0002

0.00050.0004

10

1

86

0.01

3

2

54

0.80.6

0.3

0.2

0.50.4

0.10.080.06

0.03

0.02

0.050.04

Water flow in kg/h

Pres

sure

dro

p in

mm

WC

Pressure drop type 15

L = 490L = 350L = 150L = 70

1000100103 34 46 68 82 2

P P[bar]

P[kPa]

1000

100

800600

1

300

200

500400

8060

30

20

5040

1086

3

2

54

0.1

0.01

0.080.06

0.0001

0.03

0.02

0.050.04

0.0080.006

0.003

0.002

0.0050.004

0.0010.00080.0006

0.0003

0.0002

0.00050.0004

10

1

86

0.01

3

2

54

0.80.6

0.3

0.2

0.50.4

0.10.080.06

0.03

0.02

0.050.04

Water flow in kg/h

Pres

sure

dro

p in

mm

WC

Pressure drop type 20

L = 150L = 250L = 490

L = 70

3 34 46 68 82100010010

2

P P[bar]

P[kPa]

1000

100

800600

1

300

200

500400

8060

30

20

5040

1086

3

2

54

0.1

0.01

0.080.06

0.0001

0.03

0.02

0.050.04

0.0080.006

0.003

0.002

0.0050.004

0.0010.00080.0006

0.0003

0.0002

0.00050.0004

10

1

86

0.01

3

2

54

0.80.6

0.3

0.2

0.50.4

0.10.080.06

0.03

0.02

0.050.04

Water flow in kg/h

Pres

sure

dro

p in

mm

WC

Pressure drop type 16

L = 280 L = 150L = 050

1000100103 34 46 68 82 2

P P[bar]

P[kPa]

1000

100

800600

1

300

200

500400

8060

30

20

5040

1086

3

2

54

0.1

0.01

0.080.06

0.0001

0.03

0.02

0.050.04

0.0080.006

0.003

0.002

0.0050.004

0.0010.00080.0006

0.0003

0.0002

0.00050.0004

10

1

86

0.01

3

2

54

0.80.6

0.3

0.2

0.50.4

0.10.080.06

0.03

0.02

0.050.04

Water flow in kg/h

Pres

sure

dro

p in

mm

WC

Pressure drop type 21

L = 050L = 150L = 280

1000100103 34 46 68 82 2

P P[bar]

P[kPa]

1000

100

800600

1

300

200

500400

8060

30

20

5040

1086

3

2

54

0.1

0.01

0.080.06

0.0001

0.03

0.02

0.050.04

0.0080.006

0.003

0.002

0.0050.004

0.0010.00080.0006

0.0003

0.0002

0.00050.0004

10

1

86

0.01

3

2

54

0.80.6

0.3

0.2

0.50.4

0.10.080.06

0.03

0.02

0.050.04

Water flow in kg/h

Pres

sure

dro

p in

mm

WC

Type L/metre

10 0.65

11 1.33

15 0.98

16 1.98

20 1.32

21 2.66

Water content in litres

Pressure drops

Type 10 Type 15 Type 20

Type 11 Type 16 Type 21

Pressure drop type 10

1000100103 34 46 68 82 2

L = 150L = 70

L = 490L = 350

P P[bar]

P[kPa]

1000

100

800600

1

300

200

500400

8060

30

20

5040

1086

3

2

54

0.1

0.01

0.080.06

0.0001

0.03

0.02

0.050.04

0.0080.006

0.003

0.002

0.0050.004

0.0010.00080.0006

0.0003

0.0002

0.00050.0004

10

1

86

0.01

3

2

54

0.80.6

0.3

0.2

0.50.4

0.10.080.06

0.03

0.02

0.050.04

Water flow in kg/h

Pres

sure

dro

p in

mm

WC

Pressure drop type 11

L = 050

L = 280L = 150

1000100103 34 46 68 82 2

P P[bar]

P[kPa]

1000

100

800600

1

300

200

500400

8060

30

20

5040

1086

3

2

54

0.1

0.01

0.080.06

0.0001

0.03

0.02

0.050.04

0.0080.006

0.003

0.002

0.0050.004

0.0010.00080.0006

0.0003

0.0002

0.00050.0004

10

1

86

0.01

3

2

54

0.80.6

0.3

0.2

0.50.4

0.10.080.06

0.03

0.02

0.050.04

Water flow in kg/h

Pres

sure

dro

p in

mm

WC

Pressure drop type 15

L = 490L = 350L = 150L = 70

1000100103 34 46 68 82 2

P P[bar]

P[kPa]

1000

100

800600

1

300

200

500400

8060

30

20

5040

1086

3

2

54

0.1

0.01

0.080.06

0.0001

0.03

0.02

0.050.04

0.0080.006

0.003

0.002

0.0050.004

0.0010.00080.0006

0.0003

0.0002

0.00050.0004

10

1

86

0.01

3

2

54

0.80.6

0.3

0.2

0.50.4

0.10.080.06

0.03

0.02

0.050.04

Water flow in kg/h

Pres

sure

dro

p in

mm

WC

Pressure drop type 20

L = 150L = 250L = 490

L = 70

3 34 46 68 82100010010

2

P P[bar]

P[kPa]

1000

100

800600

1

300

200

500400

8060

30

20

5040

1086

3

2

54

0.1

0.01

0.080.06

0.0001

0.03

0.02

0.050.04

0.0080.006

0.003

0.002

0.0050.004

0.0010.00080.0006

0.0003

0.0002

0.00050.0004

10

1

86

0.01

3

2

54

0.80.6

0.3

0.2

0.50.4

0.10.080.06

0.03

0.02

0.050.04

Water flow in kg/h

Pres

sure

dro

p in

mm

WC

Pressure drop type 16

L = 280 L = 150L = 050

1000100103 34 46 68 82 2

P P[bar]

P[kPa]

1000

100

800600

1

300

200

500400

8060

30

20

5040

1086

3

2

54

0.1

0.01

0.080.06

0.0001

0.03

0.02

0.050.04

0.0080.006

0.003

0.002

0.0050.004

0.0010.00080.0006

0.0003

0.0002

0.00050.0004

10

1

86

0.01

3

2

54

0.80.6

0.3

0.2

0.50.4

0.10.080.06

0.03

0.02

0.050.04

Water flow in kg/h

Pres

sure

dro

p in

mm

WC

Pressure drop type 21

L = 050L = 150L = 280

1000100103 34 46 68 82 2

P P[bar]

P[kPa]

1000

100

800600

1

300

200

500400

8060

30

20

5040

1086

3

2

54

0.1

0.01

0.080.06

0.0001

0.03

0.02

0.050.04

0.0080.006

0.003

0.002

0.0050.004

0.0010.00080.0006

0.0003

0.0002

0.00050.0004

10

1

86

0.01

3

2

54

0.80.6

0.3

0.2

0.50.4

0.10.080.06

0.03

0.02

0.050.04

Water flow in kg/h

Pres

sure

dro

p in

mm

WC

Weight & water content

Page 11: BuilT-in - Jaga · PDF fileBS H 135>185 B d h h H 80 08 ... Product code: BIWW Built-in ... 300 75/65/20 544 680 815 951 1087 1223 1359 1495 1631 1903 2174 2446 2718 2990 3262 3533

Jaga Heating Products (UK) Ltd | www.jaga.co.ukT: +44 (0)1531 631 533 | F: +44 (0)1531 631 534 | [email protected]

1 The guarantee is valid only if the equipment is properly and correctly used, by its first owner and if installed in accordance with the norms

and instructions as detailed in the instruction leaflet and current industry standard practices.

2 The guarantee only applies to the equipment and the spare parts supplied by Jaga. Jaga has the choice between repair and replacement

of the equipment or the spare parts. If any modifications have been made by Jaga to the standard product design, Jaga reserves the right to replace the guaranteed equipment with equivalent products or spare parts.

3 The period of guarantee is mentioned in this certificate. The guarantee decreases every year on a straight line basis by an equal percentage

in order to reach a zero guarantee at the end of the guarantee period (e.g. for a period of 10 years the annual decrease of the guarantees 10% of the invoiced value). repaired or replaced product is guaranteed through to the end of the original guarantee period.

4 The guarantee is valid only on products displaying the appropriate identification information concerning product type and series. No

guarantee is granted on equipment or spare parts lacking this information, on equipment where this information has been removed or altered, or on equipment that has been repaired or modified by persons not authorised by Jaga to carry out this work.

5 The customer is responsible for any damage caused as a result of errors in installation or use of incorrect fittings, or for any damage

caused by electrical connections, faulty or damaged electrical installations or appliances, erroneous voltage or hydraulic pressure and all other errors not directly related to the product delivered by Jaga. The guarantee is also revoked when unsuitable parts or components are used. The guarantee for our heat exchangers is not valid if they are regularly drained, or if they are heated by means of industrial water, steam or water saturated by excessive quantities of oxygen. The quality of the system ater has to be in accordance with the VDI 2035-2 directives. The guarantee is also not applicable if the heat exchangers are placed in unsuitable atmospheric surroundings, such as but not exclusively ammonia, caustic substances etc.

6 This guarantee excludes damage due to incorrect handling and/or use of the equipment, or due to formation of lime deposits, incorrect use

of the safety valve, or to all equipment that is incorporated into the building in a way that means it cannot be accessed normally.

7 Any work undertaken or product supplied as a result of a guarantee claim that proves not to be valid will be charged for. Product supplied

will be invoiced at the customer’s standard purchasing terms, and labour will be charged at £50 per hour with a minimum labour charge of £200.

8 The guarantee period starts from the date of the invoice for supply of the products covered by the guarantee. If the invoice is not available,

the date of production will be used based on the product ID number/series.

9 Only the courts of judicial district Hasselt (Belgium) are authorised to deal with disputes arising from this guarantee. It will apply Belgian

law even when sales involved are subjects of EU member states as well as non-EU member countries.

Jaga Guarantee information

Heat exchanger

Casings and components

Valves for Low-H2O heat exchangers