74
Confidential 1 Burners for co-generation applications

Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Confidential•1

Burners for co-generation applications

Page 2: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives Driving Progress

Gas and Oil fired Post Combustion Burners

Page 3: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives

Fresh air fan

TEG FIRING

FRESH AIR FIRING (auxiliary mode)

Gas turbine generator

HRSG

Electricpower

Steam turbine generator

Fuel gas

By-pass stack

Source : Pillard

TYPICAL COMBINED CYCLE/COGENERATION SCHEME

Page 4: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives Driving Progress

Our burners have been developed and testedin our test center in Marseilles for 25 years

Page 5: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

5

TEST RIG FOR INDUCT BURNERS 2 stages combustion 2 x 4 MW

water cooler

NOx, CO, temp.measurement

Page 6: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

VALIDATATION OF CFD MODELS:SIMULATION OF BURNER AT RESEARCH CENTER

GOAL OF THE SIMULATIONS:

� Validation of physical cfd models: Comparison of temperature profiles, shape and flame length with experimental results

� "CFD" is a tool for comparative prediction of possible solutions

CHARACTERISTICS OF THE SIMULATIONS:

� unsteady

� hybrid mesh (1M cells)

� turbulence: kepsilon "realizable" model

� combustion: Eddy dissipation/finite rate model

� species: O2, CO2, H2O, CH4, CO, N2

� radiation: P1

Page 7: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives Driving Progress

First Solution: Induct burners

Row type, Gas Firing

Page 8: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

REBURNFLAMDuct Burner Systems

Page 9: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives-Pillard

Scanner coolingair header

Ignitor gasheader

Main gasheader

Flame scannerIgnitorShield

Thermal insulation

Rigid steel frame

GAS-FIRED INDUCT BURNERSIdentification of Main Components

Page 10: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives

Source : Pillard

GAS-FIRED INDUCT BURNERSBurner Overview

Page 11: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives

Gas fired induct burners

(Patents : FR 87/14686, CAN 580.005,Europe 88.402659.2).

Applications: HRSG supplementary firing.

Advantages: Performances in compliance with the latest European Standards for emission

TEG mode: Reburning of a part of NOx from GT: (downstream rate < upstream rate).

Fresh air mode, natural gas firing:

(mg/Nm3 eq. NO2, 3 % O2, dry basis)NOx < 200 without FGR

NOx < 100 with FGR

REBURNFLAM® GAS FIRED INDUCT BURNERSPerformances at a glance….

Page 12: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

DIFFERENT BURNER DESIGNSDEVELOPED IN OUR TEST CENTER

12

Along the 25 past years we developed and tested num erous designs to cope with:• More and more stringent TEG characteristics

– Lower O2 content

– Higher water vapour

• Burner installation between modules– Lower temperature

– Lower TEG velocity

– Shorter space available to develop the flames

• Requirements concerning the temperature profile

• NOx, CO emissions

• Operation with fresh air

Page 13: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives

GAS-FIRED INDUCT BURNERSElementary Burner Shield Module

Design flexibility• Suitable to any duct configuration

Combustion advantages• High flame stability over wide velocity range

• High turn-down

• Even temperature distribution

• Low pressure drop

Mechanical reliability• Heat resistant: refractory materials

• Strong and precise (Wax castings)

• Designed to allow thermal expansion

C-152718 0

Page 14: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives

GAS-FIRED INDUCT BURNERSElementary Burner Shield Module type 1

C-152718 0

Basic wings

Page 15: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives

GAS-FIRED INDUCT BURNERSElementary Burner Shield Module type 1 + central tip

C-152718 0

Basic wings + central tip

Page 16: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives

GAS-FIRED INDUCT BURNERSElementary Burner Shield Module type 3

C-152718 0

Large wings

Page 17: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives

GAS-FIRED INDUCT BURNERSElementary Burner Shield Module type 4

C-152718 0

Very large wings

Page 18: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

SELECTION OF INDUCT BURNER DESIGN1st CRITERIA: TEG CARACTERISTICS

18

0

100

200

300

400

500

600

700

10 12 14 16 18 20

TE

G T

empe

ratu

re (

°C)

TEG Oxygen (% vol.)

Standard wings

Large wings

Very large wings

Operating zone

Non Operating zoneAugmenting Air Required

Page 19: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

SELECTION OF BURNER DESIGN2nd CRITERIA: TEG VELOCITY

19

Design Basic Large wing Very large wing

Range of TEG velocity (m/s)

20 to 40 16 to 25 12 to 25

Burner output (kW/m)

2600 2600 3600

Flame length (m) 4,5 4,5 4

Above data are typical and differ according to the operating conditions

Page 20: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

SELECTION OF INDUCT BURNER DESIGN2nd CRITERIA: TEG VELOCITY

20

Flame length of basic shield according to output

Page 21: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

SELECTION OF INDUCT BURNER DESIGNSelection based on the following criteria

21

Price

TEG characteristics: O2 / Temperature

Temperature profile / vs Flame length

About the same emissions (NOx, CO) in TEG

Page 22: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

TEMPERATURE PROFILE:MAIN PARAMETERS

22

1. Distance from burner to first HRSG tubes

2. Heat release per shield (i.e number of rows)

3. Overall flow distribution

4. Type of shield

Page 23: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

In house CFD Study

A team of experts in CFD & Combustion simulation

FLUENT Software

23

Before correction

Flow correction devices (if necessary) Final result

Temperature distribution (top view)

HRSG’s inlet temperature distribution

Temperature distribution (side view)

Page 24: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives Driving Progress

Some References

Page 25: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

FivesC-152722 0

Dubai Electricity Water Authority (Power Production & Desalting Water Treatment )

T.E.G. mode :

Upstream temp. : 275 to 550 °C (530/1020 °F)

Downstream temp. : 620 °C (1150 °F)

O2 content in T.E.G. : 14,3 vol %

T.E.G flow : 1 254 000 kg/hr (2 765 000 Lb/hr)

Burner characteristics :

Heat release : 128 MW[LHV] ie(485 MMBtu/hr [HHV])

24 rows of 16 shields each

Nat. Gas firing

Inside dimensions

Height : 6 m ( 19'8")

Width : 7 m (23')

GAS FIRED INDUCT BURNERSDUBAI

Page 26: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives

GAS FIRED INDUCT BURNERSReferences: ANSALDO – SONDEL Millazzo (It)

Client : Ansaldo (Italy) for Sondel Milazzo

Height : 15m67 (51’5’’) Width : 8m47 (27’10’’)

T.E.G. mode:

Upstream/ Downstream temp. : 330/640°C (626/1184°F)

T.E.G. flow : 1 125 000 kg/h (2 700 000 Lb/hr)

O2 content : 13.77 %

Gas turbine model : GE Frame 9

Ambient air (A.A.) mode :

Upstream/ Downstream temp. : 20/640°C (68/1184°F)

Fresh Air mode : 824 000 kg/h (1 815 000 Lb/hr)

Burner characteristics:

Max. heat capacity : 170 MW LHV (644 MMBtu/hr HHV)

10 rows of 35 shields each

Page 27: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GAS FIRED INDUCT BURNERSANSALDO – Nehuenco (Chile)

T.E.G. mode :• Upstream T°: xx °C

• Downstream T°: xx °C

• O2 content in T.E.G.: 13.5 %vol

Gas turbine model : V97 3A

Burner Characteristics• Max Heat Input 60 MW TEG

• 4 rows of 39 shields each

Height : 9 m Width : 9 m

Page 28: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GAS FIRED INDUCT BURNERSALSTOM FRANCE – Eurolysine, Amiens (F)

Burner characteristics: • 87 MW Heat Input

• 4 vertical rows x 31 shields each

Gas turbine model : LM 6000

Low NOx emission, in fresh air mode : 157 mg/m3 (at 3% O2)

Height : 7.1 m Width : 3.9 m

Page 29: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GAS FIRED INDUCT BURNERSDOOSAN – RAS LAFFAN Water & Power (Qatar)

Four(4) Units, 150 MW

Upstream T°: 560 °C

Upstream T°: 863 °C

O2 content in T.E.G.:

Low NOx emission:• TEG mode:

• Partial Reburning of NOx produced by GT(NOx downstream rate < upstream rate).

• Fresh air mode, nat. gas firing:

• (mg/sm3 eq. NO2, 3 % O2, dry basis)

• NOx < 200 without FGRNOx < 100 with FGR

(4 Units)

T.E.G. mode :• Upstream / Downstream T°: 560 / 863°C

• O2 content in T.E.G.:

Burner characteristics:• Max. heat capacity : 150 MW

• 11 rows of 32 shields each

Low NOx emission:• TEG mode:

– NOx downstream rate < upstream rate (Partial Reburning of NOx produced by GT).

Height : 11.3 m Width : 6.5 m

Page 30: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GAS FIRED INDUCT BURNERSHHI For PP11 (Ryad, Saoudi Arabia)

(7Units)

T.E.G. mode :• Upstream / Downstream T°: 550°C/850°C

• O2 content in T.E.G.: 11.98 to 12.40%

Burner characteristics:• Max. heat capacity : 140 MW

• 7 rows of 20 MXW each

NOx, CO emissions < 50 mg/MJHeight : 20.4 m Width : 7.7m

Page 31: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GAS FIRED INDUCT BURNERSMACCHI – PETROBRAS (Brazil)

(2 Units)

T.E.G. mode :• Upstream / Downstream T°: 532°C/871°C

• O2 content in T.E.G.: 13.57%

Burner characteristics:• Max. heat capacity : 111 MW

• 12 rows

Height : 18 m Width : 4 m

Page 32: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GAS FIRED INDUCT BURNERSCERREY – Salamanca (Mexico)

(2 Units)

T.E.G. mode :• Upstream / Downstream T°: 632°C / 706°C

• O2 content in T.E.G.: 12.69%

Burner characteristics:• Max. heat capacity : 26 MW

• 2 rows

Height : 13 m Width : 6.2 m

Page 33: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GAS FIRED INDUCT BURNERSEM ALLIANCE – NOVOBEREZNIKOVSKAYA RUSSIA

(2 Units)

Burner characteristics:• Max. heat capacity : 46.8

MW

• 4 rows 1 post

Height : 12 m Width : 4.5 m

Page 34: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GAS FIRED INDUCT BURNERSNOOTER ERIKSEN IT – FACILITY D (QATAR)

(6 Units)

T.E.G. mode :• Upstream / Downstream T°: 600°C / 706°C

• O2 content in T.E.G.: 10.75%

Burner characteristics:• Max. heat capacity : 160 MW

• 6 rows

Height : 13 m Width : 6.2 m

Page 35: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GAS FIRED INDUCT BURNERSCOFELY FOR PEUGEOT (France)

T.E.G. mode :• Upstream / Downstream T°: 545°C / 850°C

• O2 content in T.E.G.: 13,4% vol.

• Flow rate: 37,89 kg/s

• Output: 15 MW

Fresh air mode + FGR• Upstream / Downstream T°: 90°C / 930°C

• O2 content in mixture: 18% vol.

• Total flow rate: 31,3 kg/s (of which 23,6 kg/s of FA)

• Output: 32 MW

Page 36: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

FLAME 13,5m/s 10,7% O2 500kw

Fives-Pillard

VIDEO FLAME 13,5m/s 10,7% O2 500kw

Page 37: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives

RAS LAFFAN (DOOSAN-Qatar) 150MW TEG

SONDEL MILAZZO (ANSALDO-Sicilia) 170MW AA / 70MW TE G

SHARJAH (ANSALDO-UAE) 45MW TEG

NEHUENCO (ANSALDO- Chile) 60MW TEG

TIOXIDE (Standard Fasel Lentjes – Calais France) 90M W TEG

ALHIDD II (ALSTOM POWER– Bahrain) 3x160MW TEG

GAS FIRED INDUCT BURNERSOther References High Power range…

Page 38: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives Driving Progress

Second Solution: Duct Burner with Mobile Flaps

(Row Burner, Gas Firing)

Page 39: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives 0

GAS FIRED INDUCT BURNERSWith Mobile Flaps for Fresh Air mode

Page 40: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

FivesC-154045 0

GAS FIRED INDUCT BURNERSReferences: CNIM BABCOCK – Salins Varangevilles (F)

74 MW, equipped with automated dampers for optimiz ed FA mode

Page 41: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives Driving Progress

Third Solution: Circular GRC Burner

(Swirl type, Gas and/or Oil Firing Burners with or without mobile flaps)

Page 42: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GRC INDUCT DUAL FUEL FIRED BURNERSPerformances at a glance…

Patented concept: Europe .430005.3, USA 09/032-717; Europe 430026.5.

High flame stability

Removable combustion heads & Oil guns

Low emissions in TEG and Fresh air Mode

Left: ALSTOM - ARKEMA Marseilles (F):

2 x 26 MW Heat Input

Natural Gas & Heavy OIl

Gas turbine model : MARS 100

Page 43: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GRC INDUCT DUAL FUEL FIRED BURNERS Oil gun removal enables frequent cleaning (HFO burning)

Principle of Oil Gun removal (from side)

Page 44: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GRC INDUCT DUAL FUEL FIRED BURNERSOPERATING CONDITIONS

Aumenting air ratio depends on operating conditions (from stoechiometric)• 2% for operating conditions above the blue line

• 8% for operating conditions between the blue and the red lines

Page 45: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GRC INDUCT DUAL FUEL FIRED BURNERSFLAME LENGHT

0

1

2

3

4

5

6

7

8

0 5 10 15 20 25 30

Fla

me

leng

th (

m)

TEG Velocity (m/s)

Flame Length (550°C - O2 = 13% vol.)

20 m/s

30 m/s

35 m/s

40 m/s

Page 46: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GRC INDUCT DUAL FUEL FIRED BURNERS HHI - PETROBRAS (Romania)

Natural Gas & Extra Heavy Fuel Oil

4 x 15 MW

GT Model: M5 5001.2

Page 47: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GRC INDUCT DUAL FUEL FIRED BURNERSOMAN REFINERY Co.

2 Units

Process Gas & Diesel Oil

TEG & Fresh Air Mode• TEG mode 2 x 18 MW

• FA mode 2 x 45 MW

Page 48: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives 48

GRC INDUCT DUAL FUEL FIRED BURNERS DOOSAN: FUJAIRAH 1 (UAE)

4 x 235 MW GRC induct Burner

Main fuel: Natural Gas

Secondary Fuel: Diesel Oil

Operating in Gas Turbine Exhaust

TEG characteristics:

• Flow 268 to 402 kg/s

• Temperature 445 to 593 °C

• O2 contain 12,85 to 15,64 %vol .

Page 49: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Fives 49

GRC INDUCT DUAL FUEL FIRED BURNERS ALSTOM: FUJAIRAH 2 (UAE)

5 x 240MW GRC induct Burner

Main fuel: Natural Gas

Secondary Fuel: Diesel Oil

Operating in Gas Turbine Exhaust Gases stream:

Flow (min – max): 280 to 630 kg/s

Temperature (min – max): 445 to 585 °C

O2 contain (min – max): 9.8 to 16.5 %vol

Page 50: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

50

60 DUAL FUEL BURNER HEAD of 20 MW each

Fives

Page 51: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

51

60 DUAL FUEL BURNER HEAD of 20 MW each

Page 52: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

52

60 DUAL FUEL BURNER HEAD of 20 MW each

Page 53: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

53

60 DUAL FUEL BURNER HEAD of 20 MW each

Page 54: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Interconnecting piping / wiring

Formation 17-02-2015 Duct Burners 54

Page 55: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Formation 17-02-2015 Duct Burners 55

HIGH PRESSURE PUMPING SET

Page 56: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

ROWS LOOSE SUPPLIED

Formation 17-02-2015 Duct Burners 56

Page 57: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Exemple of burner insert

57

Page 58: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Cabling and Wiring

58

Page 59: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Typical PID

59

Page 60: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Typical FCD

60

CFD DWG

Page 61: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Formation 17-02-2015 Duct Burners 61

NATURAL GAS MAIN FUEL SKID

Page 62: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Formation 17-02-2015 Duct Burners 62

NATURAL GAS MAIN FUEL SKID

Page 63: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Formation 17-02-2015 Duct Burners 63

OIL MAIN FUEL SKID

Page 64: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GAS PRESSURE REDUCING STATION

Formation 17-02-2015 Duct Burners 64

Page 65: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Duct / Duct insulation

65

Page 66: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

66

INDIVIDUAL SHUT OFF SKID

Page 67: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

67

COOLING AIR FAN

Page 68: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

68

Page 69: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Formation 17-02-2015 Duct Burners 69

Page 70: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

70

Page 71: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

71

Page 72: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

72

FOB DELIVERY

Page 73: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

Reference List

Formation 17-02-2015 Duct Burners

•DUAL FIRED INDUCT BURNERS•Around 200 burner heads•More than 3 000 MW

•GAS FIRED INDUCT BURNERS•Around 300 burners•More than 4 700 MW

Page 74: Burners for co-generation applications - icep84.com · 2017-07-26 · Elementary Burner Shield Module type 1 C-152718 0 Basic wings. Fives GAS-FIRED INDUCT BURNERS Elementary Burner

GRC INDUCT DUAL FUEL FIRED BURNERS …and more than 30 other references worldwide…

T.E.I. – Tate & Lyle Sugar (UK): 1 x 55 MW

BABCOCK – SONATRACH Arzew (Al) 1 x 76 MW

DESA OTAC – ZORLU Energy (Tur) 6 x 8 MW

…… ( see our reference list)