Bv r Install

Embed Size (px)

Citation preview

  • 8/19/2019 Bv r Install

    1/20

     

    QTC – Quality Technology Centre, Austria Page: 1 of 20

    BVR+ Installation InstructionsDate: 2007-12-05

    BVR+ Software Version: > 7.0.0

    1. General Information

    1.1 This instruction describes the first time and upgrade installationprocedure for BVR+ software including required drivers andsoftware packages.

    1.2 BVR+ Software runs on WINDOWS NT, WINDOWS 2000 andWINDOWS XP. Neither the target BVR+ nor the BVR+ DEMOversion support the operating system WINDOWS 98.

    1.3 Please do not install or update any software on MEB 95

    electronics, if you do not know this software package, you do notneed the new software functionality or you do not exactly knowhow to install or update the software.

    1.4 For the required basic software installation for MEB 95, pleaseselect the required software from the correct sub-folders from theattached CD-ROM (QTC BVR+, Software & Documentation). Before you install any software drivers or applications, check thatthe necessary hardware is installed in your MEB 95 electronics.For instance, if your MEB 95 requires communication to an MTC

    system, select the folder CD-ROM-drive\MTC_PLC725_PLC711\andinstall the software package from Advantech. (See section 5 formore information). The communication to a Siemens PLC Systemrequires different software from the folder CD-ROM-drive\Siemens_CP5611. Note, that in all MEB 95 electronics foroffline noise tester (e.g. MVH) the MTC communication board PLC725 from Advantech is installed.

    1.5 Before you install any software driver for certain hardware,make sure, that the correct hardware is installed and correct

    hardware settings (e.g. jumpers) have been made.

    1.6 In MEB 95 electronics, different type of CPU boards are used.Before you install software drivers for the CPU board, make surethat you have selected the correct CPU board type. If you do notknow the installed CPU board type, restart the MEB 95 and note

  • 8/19/2019 Bv r Install

    2/20

     

    QTC – Quality Technology Centre, Austria Page: 2 of 20

    the CPU board type in the start-up screen or have a look in thesystem settings. The attached CD-ROM supports two differenttypes of CPU boards as follows:

    - Intel Pentium 3 Processor 866 MHz

    - Intel Pentium M processor 1.8 GHz

    1.7 If the MEB 95 electronics does not support a CD-ROM drive orUSB interface (old MEB 95 housing), connect an external orinternal CD-ROM drive on MEB 95. Software installations via floppydisks are not supported for BVR version higher than V6.4.12

    1.8 Before you upgrade very old BVR software version (< V5.82,with operating system Windows NT), contact QTC for additionalinformation. A new installation of the operating system including a

    hardware upgrade with better performance (CPU speed, memory,interfaces…) is proposed and might be necessary.

    1.9 If you connect the MEB 95 to a local LAN network, take careabout virus protection software. On some newer systems, QTC hasinstalled the shareware “AntiVir” program or the SKF’s standardvirus protection tool “eTrust”. Both packages must be updated on aregular base from customer. Contact your local IT department forappropriate virus protection software, software licence andinstallation instruction.

    1.10 If you report software or hardware problems of MEB 95electronics or BVR+ software to QTC, please indicate the serialnumber of MEB 95 and all important software versions. (See theabout screen in BVR+ software).

    1.11 The name of the system folder for the operating system(WINDOWS 2000 or WINDOWS XP) must be C:\WINNT. If not,copy the system files manually to your system folder duringinstallation.

    1.12 Take care, that this user account has administrator privilegesduring all installations.

  • 8/19/2019 Bv r Install

    3/20

     

    QTC – Quality Technology Centre, Austria Page: 3 of 20

    1.13 If you require additional information, or you are not sureabout the latest software version, please contact SKF QTC by e-mail as follows:

    - Maximilian Bichler: [email protected] 

    - Johann Gebesmair:  [email protected] - Wolfgang Stöcher: [email protected] 

    - Ferdinand Kerbl: [email protected] 

    2. Installation of operating system.

    2.1 For a new installation, it is proposed to use the WINDOWS XPoperating system. Windows 2000 is also possible.

    During installation of the operating system install or select thefollowing features, if it is possible with your hardwarerequirements.

    •  VGA driver (1024x680 or 1280x1024) with display settings “Large size”. (CD-ROM installation CD)

    •  Network card drivers (CD-ROM installation CD)

    •  Printer drivers (default HP 1100)

    •  FreePDF application. (CD-ROM installation CD)

    •  Adobe Acrobat Reader application. (CD-ROM installation CD)

    •  WinZip application. (CD-ROM installation CD)•  Installation of any Anti virus application

    3. Installation or update of BVR+ Software

    3.1 Execute the file “SetupBVR_x.y.z.exe” and follow theinstructions on the screen.

    The installation file “CD-ROM-drive\BVR_ins\SetupBVR_x.y.z.exe”

    will install the following items:

    -  Installation of latest BVR+ software version in the defaultfolder c:\bvr

    -  Installation of default bearing setup files for DGBBs (ifselected)

  • 8/19/2019 Bv r Install

    4/20

     

    QTC – Quality Technology Centre, Austria Page: 4 of 20

    -  All required driver (including inf) files for the installation ofthe measurement board (AD416 or SP220)

    -  BVR+ shortcuts on desktop in programs list and auto start-up.

    -  Required images for the desktop background.

    Note: Before you install a new BVR+ software version, de-installthe old software (if available). Open “Add or Remove Program”from the Control Panel and select BVR software.

    Note: Any old BVR software on your system will be overwrittenwithout notice. If you have selected to install also the defaultbearing setups for DGBB, all old bearing setup filenames will beoverwritten. Changes or modifications, which are not saved under anew filename, will be lost. Bearing setup or job files will never be

    automatically de-installed.

    Note: All calibration data or settings, saved in the file c:\bvr.ini,will never be overwritten. New used keys will be added in the filec:\bvr\bvr.ini with default value.

    3.1.1 Select a language for installation:

    3.1.2 The next picture will show you the welcome screen. Click theNext button to continue.

    3.1.3 Read the License Agreement and click the I Agree button

  • 8/19/2019 Bv r Install

    5/20

     

    QTC – Quality Technology Centre, Austria Page: 5 of 20

    3.1.4 Select the destination folder and click the Next button

    Note: Do not modifythe defaultdestination folderC:\BVR !!!!

    3.1.5 Choose components to be installed

    3.1.6 Show the Readme file and click the Finish button

    Note: Do not run thenew BVR software, ifthe installation is notfinished.

  • 8/19/2019 Bv r Install

    6/20

     

    QTC – Quality Technology Centre, Austria Page: 6 of 20

    4. Installation of measurement board drivers

    The following instruction explains the installation of the driver for

    the measurement board. The following measurement boards aresupported:

    -  AD416 (ISA Bus)-  SP220 (PCI Bus)

    4.1 Before you install the new measurement board driver, removeany existing installation. Open the Control Panel and select Add orRemove Programs. Select the STAC driver software, and removethe software package. Restart MEB 95 if requested.

    4.2 To install the driver for the measurement board, execute thefile setup.exe in the folder c:\install\bvr\drivers\stac\drv and followthe instruction displayed on the screen. This folder was generatedduring the installation of section 3.

  • 8/19/2019 Bv r Install

    7/20

     

    QTC – Quality Technology Centre, Austria Page: 7 of 20

    4.2 Installation of the inf file for the measurement board.

    Open the control panel and double click the system icon, select thefolder hardware and click the device manager.

    Note: This section is only necessary, if you install the drive for theSP220 measurement board.

    4.2.1 Select the uninstalled PCI device (SP220) and update thedriver as follows:

    4.2.2 Select install from a list or specific location:

  • 8/19/2019 Bv r Install

    8/20

     

    QTC – Quality Technology Centre, Austria Page: 8 of 20

    4.2.3 Select the installation folder:

    4.2.4 Complete the hardware update wizard by selecting the finishbutton:

  • 8/19/2019 Bv r Install

    9/20

     

    QTC – Quality Technology Centre, Austria Page: 9 of 20

    4.2.5 After the installation, the measurement board type (SP220)must be visible in the device manager as follows.

    5. Installation of Advantech driver for PCL-725 and PCL-711.

    For BVR+ software new Advantech driver must be installed. Seefolder: MTC_PLC725_PLC711 on BVR+ CD-ROM. If an oldAdvantech driver package (V1.03, V1.4c or V2.0) is installed onyour system, it must be removed before installing the new package(see point 5.1 and 5.2 below). If an old driver package is notinstalled, continue with point 5.3 and 5.4.

    The  Advantech PCL-725   card (digital input/output board) in theMEB 95A is used to communicate with the MTC equipment. Onlymachines with MTC equipment need this card. A PCL-725 is also

    installed in offline equipment (e.g. MVH).Hardware setup for PCL-725:

    A8 A7 A6 A5 A4 A3 A2 A1HW Settings: I/O adr.(2a8-2a9): ON OFF ON OFF ON OFF ON ONJA0..JA7: ISO (isolated)JB0..JB7: ISO (isolated)

  • 8/19/2019 Bv r Install

    10/20

     

    QTC – Quality Technology Centre, Austria Page: 10 of 20

    The Advantech PCL-711B card in the MEB 95A is used to measurethe axial clearance. If the PCL-725 board is installed, also installthe PCL-711 driver.

    Hardware setup for PCL-711: A9 A8 A7 A6 A5 A4Hardware Settings: OFF OFF ON ON ON ONBase address (300-30F):JP1: -5V

    5.1 Remove old installed Advantech device driver package

    Start the old Advantech device installation manager (V1.03, 1.4c orV2.0) and remove all installed boards as follows:

    5.1.1 Press Start/Programs/Advantech Automation/ DeviceManager/Advantech Device Manager

    5.1.2 Select the installed devices for PCL-725 and click the button “Remove”.

    5.1.3 Select the installed devices for PCL-711B and click the button “Remove”

  • 8/19/2019 Bv r Install

    11/20

     

    QTC – Quality Technology Centre, Austria Page: 11 of 20

    5.2 Remove old Advantech Device Manager Programs (V1.03V1.4c or V2.0)

    Remove the old Device Manager program as follows:

    5.2.1 Open the control panel and double click the icon “Add orRemove Programs”.5.2.2 Select the currently installed program “Advantech DeviceDriver/Manager” and click the Change/Remove button.5.2.3 Select “Remove” and click the Next button.

    5.2.4 Select the OK button and follow the instruction on the screen.

    Note: Delete all read-only files by pressing the “YES” button.

    5.3 Install new Advantech Device Manger Program

    The files for the installation of the new Advantech Device Driversare on the BVR+ CD-ROM in the Folder CD-ROM-drive/install/Advantech_ins/ MTC_PLC725_PCL711.

    5.3.1 Start the file "DevMgr.exe" and follow the instructions on thescreen.

    Note: Overwrite allread-only files

    during theinstallation bypressing the “Yes”button”

  • 8/19/2019 Bv r Install

    12/20

     

    QTC – Quality Technology Centre, Austria Page: 12 of 20

    5.3.2 Install PCL725.exe and PCL 711.exe

    Execute the files "Pcl725.exe" and "Pcl711.exe" from the BVR+ CD-ROM and follow the instructions on the screen.

    5.4 Install new Advantech device drivers

    Select Start\Programs\Advantech Automation\Device Manager\Advantech Device Manager and install the device driver for PCL-725 and PCL-711as follows:

    5.4.1 Select Advantech PCL-725 and PCL-711 from the list ofsupported devices and click the Add button.5.4.2 Enter Base Address 2a8 Hex for PCL-725.5.4.3 Select PCL-711 from the list of supported devices and clickthe Add button

  • 8/19/2019 Bv r Install

    13/20

     

    QTC – Quality Technology Centre, Austria Page: 13 of 20

    5.4.4 Select settings for PCL-711 as shown in the window below.5.4.5 Click the OK button5.4.6 Click the Close button

    Note: If there are some error messages, modify the settings forinterrupt channel 5 in BIOS settings (Legacy ISA)

    Note: To test the installation, click the button “Test”

  • 8/19/2019 Bv r Install

    14/20

     

    QTC – Quality Technology Centre, Austria Page: 14 of 20

    6. Install the Background image

    If the background image is not installed automatically, follow theinstruction below.

    6.1 Unzip the requested background image from the BVR CD-ROMto the folder c:\WinNT by using the WinZip application.

    6.2 To install the background image, open the control panel anddouble click the Display.

    6.3 Select the folder Desktop and choose the correct backgroundimage.

    6.4 Modify Appearance settings: Select colour from blue to white

    only for the operating system Windows2000.

    7. Install new fonts for Unicode support

    Chinese and Bulgarian language support for BVR+ software requirethe installation of a new font. For Windows 2000 a manualinstallation is required.

    7.1 Select the folder C:\WinNT\Fonts7.2 Select the menu File\Install new fonts and install fonts as

    follows:

    - Arial Narrow (True Type), ARIALN.TTF- Arial Unicode MS (True Type), ARIALUNI.TTF

    8. Installation of PDF-Printer

    For using the feature of automatically saving reports of eachmeasured bearing the installation of the PDF-Printer ‘PDFCreator’ isnecessary.

    Run the installer "PDFCreator 0_9_3_GPLGhostscript.exe" fromBVR installation CD-ROM (see folder PDFCreator on the installationCD-ROM: CD_ROM-drive\PDFCreator) and accept all defaults.In order to get PDF-reports in color a color-printer (e.g.PDFCreator) must be configured as the default printer; otherwisePDF-reports will be generated in gray-scale.

  • 8/19/2019 Bv r Install

    15/20

     

    QTC – Quality Technology Centre, Austria Page: 15 of 20

    9. Software protection

    The BVR+ software is protected by a key file in the executiondirectory. It means you must obtain a license for every MEB 95 onwhich the software is installed and used. The license is stored in

    the file 'xxxxx.key' (xxxx being the measurement board serialnumber). Therefore each measurement board needs a uniquelicense key file.

    Notes:BVR+ software installed from QTC on MEB 95 equipment will beinstalled with a valid license key file. If you install or update BVR+software on MEB 95A electronics take attention to a valid licensekey file in the BVR+ execution directory. Do not rename or deletethe licence key file.

    If the BVR+ software is started on MEB 95 electronics (withinstalled measurement board) without valid license key file anauthorisation error will be reported and you will only be able to runBVR+ software in demo mode (MeasBoard = 0 in BVR.ini)

    Note: This window is only displayed, ifin the BVR+ system folder (c:\bvr) aninvalid licence key file (e.g. 91107.keyor 63006.key) is available.

    How to get and install the software license key file?

    1. Start the BVR+ software without any key file in the executiondirectory and with renamed or deleted BVR.ini file. The serialnumber of the measurement board will be displayed in the windowabove (5digits).

    Note: In BVR.ini file important calibration data and settings aresaved (e.g. machine settings, passwords, calibration data,..). Donot delete this file.

  • 8/19/2019 Bv r Install

    16/20

     

    QTC – Quality Technology Centre, Austria Page: 16 of 20

    Note: The serial number of the measurement board is alsoindicated on the measurement board (white label)

    2. If you do not have a valid license key file, send the measuringboard serial number to QTC and request the BVR+ license key file

    (xxxxx.key)

    3. After you have a valid license key file (xxxxx.key) copy it intothe BVR+ execution directory (default: c:\bvr) and modify the filec:\bvr\bvr.ini as follows:

    [SYSTEM]MeasBoard=255

    With this setting, the BVR+ software will search for the installed

    measurement board (AD416 or SP220) during the next start-up ofthe software. After the correct measurement board has beendetected, the key MeasBoard will be modified as follows:

    [SYSTEM]MeasBoard=0 for BVR+ DEMO software versionMeasBoard=1 for AD416MeasBoard=2 for SP220

  • 8/19/2019 Bv r Install

    17/20

     

    QTC – Quality Technology Centre, Austria Page: 17 of 20

    10. Installation of Siemens Prodave S7 Mini application

    Note: This procedure is only valid for the operating systemWindows2000. For WindowsXP, the software package “PRODAVEMPI mini V6.0” has to be installed. The installation is similar to theinstallation for Windows2000. Just follow the instructions displayedon the screen.

    For communication between MEB95 (BVR+ software) and Siemenscontrol system (S7 300 PLC) additional hardware and software arerequired. Only vibration tester with Siemens PLC system needs theadditional board in the MEB 95 (CP 5611) and the installation ofProdave S7 Mini software package. The CP 5611 module isequipped with a profibus interface and it is intended for use in PCswith a PCI bus interface to be able to communicate with a Siemens

    PLC system. The CP 5611 module can be installed in any free PCIslot in MEB 95A

    Note: Software download for any Siemens PLC system is notsupported with this software package. Additional software isrequired, which is not supplied with the MEB 95A.

    The software for operating the CP 5611 module is "PRODAVE MPImini V5.5" software package, which has to be installed as follows:

    1. Run the program "setup.exe" from disk 1 (see folderSIEMENS_CP5611 on BVR+ installation CD-ROM).2. Select installation language (default English) and click Nextbutton.3. Select the default destination folder(...\Siemens\Prodave_S7_Mini) and click Next button.4. Select installation user defined and click Next button5. Select components as shown in the window below and click theNext button.

  • 8/19/2019 Bv r Install

    18/20

     

    QTC – Quality Technology Centre, Austria Page: 18 of 20

    6. Select program folder "PRODAVE_S7_MINI and click Nextbutton. After the installation process is finished click the Finishbutton and close the installation program.7. Open the Device Manager as follows and remove one item.For windows2000 select My Computer / Control Panel / System andselect the Hardware folder. Press the Device Manager button.

    Select "Other devices / Network Controller" in the Device ManagerWindow (see window above) and remove this item by pressing theDelete key.Close the device manger.8. Restart Windows operating system.Click the Start button and select Shut Down.9. Open the Device Manager again. A new item (SIMATIC NET / CP5611) as shown in the window below is shown.

  • 8/19/2019 Bv r Install

    19/20

     

    QTC – Quality Technology Centre, Austria Page: 19 of 20

    Close the Device Manager

    10. Open the configuration program for CP 5611 card as follows:

    Click Start and select Programs / Prodave_S7_MINI / PG-PCinterface and select PCI 5611 (PROFIBUS) in the first window asfollows:

    11. Click the button Properties and configure the displayed windowas follows:

  • 8/19/2019 Bv r Install

    20/20

     

    QTC Quality Technology Centre Austria Page: 20 of 20

    Click the OK button

    12. Click the Diagnostics button.

    For diagnostics click the Test and Read button. If everything iscorrect installed and the MEB 95A is connected with the SiemensPLC system the following window with appropriate statusinformation is displayed.

    Note: Without a connection between MEB 95 and Siemens PLCsystem bus node 2 will not be switched on