12

BYOUNG

Embed Size (px)

DESCRIPTION

TEMPERATURE CONTROL UNITS

Citation preview

Page 1: BYOUNG
Page 2: BYOUNG

PROFILE............................................................................................................... 03

TEMPERATURE.CONTROL.UNITS................................................................ 04

WATER.CIRCULATION..1�0℃,.140℃,.160℃,.180℃........................... 06

OIL.CIRCULATION..�00℃,.�50℃,.300℃................................................. 08

CHILLERS............................................................................................................ 10

INDEX

Page 3: BYOUNG

3

PROFILE

EXIST WITH THE AMBITITON TO BECOME A

LEADING COMOANY WITHIN THE FILED OF THE

TEMPERATURE-CONTROLLED FOR MORE THAN 20 YEARS’EXPERIENCE IN THIS FIELD.

HAS BEEN DEVELOPING SPECIFIC SKILLS TO MAKE

SURE OUR CUSTOMERS IMPROVE PERFORMANCE

AND INCREASE THE QUALITY OF THEIR PRODUCTS, AS WELL AS THE EFFECTIVENESS OF THEIR PROCESSES.

“CUSTOMER-IMPORTANT, PROFESSIONAL-SERVICE,TECHNOLOGY-INNOVATED, HIGH-END QUALITY”

TO ACHIEVE THIS GOAL, , CONTINUES & FOCUS ON:

Page 4: BYOUNG

4

TEMPERATURE CONTROL UNITS

FEATURES

ELECTRICAL CONTROL CABINET AND MACHINE BODY ARE SEPARATED,

GOOD EFFECTIVE ISOLATION.

START-UP, FLUID-REFILLED AND AIR-DRAINED OF THE PIPING AUTOMATICALLY,

AVOID OUT OF ORDER OF HEATER & PUMP.

PINPING IS MADE AS STAINLESS STEEL ONE STRUCTRE FORMATION, AVOID LEAKAGE.

BUILT-IN 4×4 MATERIAL SELECTORS, COMPACT DIMENSIONS.

JAPAN MADE“OMRON, YAMATAKE”P.I.D. INTERIOR COUNTED,

ACCURACY:±0.5℃ (T/TS SERIES)

ACCURACY:±0.1℃ (T/TAS SERIES/WATER TYPE ONLY)

MAJOR ELECTRIC PARTS ARE IMPORTED FROM JAPAN, EUROPE, SUCH AS:

”FUJI, OMRON, YAMATAKE, O.D.E.”

PUMP COMES FROM “SPECK, CALPEDA. TECO”

COMPLETE WITH SAFETY PROTECTION AND BREAK DOWN INDICATION SYSTEM,

USER-FRIENDLY OPERATION.

TEMP. RANGE:120℃, 140℃, 160℃, 180℃ ⋯⋯⋯⋯⋯⋯ WATER CIRCULATION

200℃, 250℃, 300℃ ⋯⋯⋯⋯⋯⋯⋯⋯⋯ OIL CIRCULATION

MULTI-FUNCTION TEMPERATURE CONTROL UNITS

(PATENT NO. TAIWAN 212252, M247811, CHINA ZL 02201464.0 ZL 200420006901.3)

THE ADDITIONAL FUNCTIONS AS FOLLOW:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

A. STRONG POINT FOR TEMPERATURE DEVIATION WARNINGWHEN THE DEVIATION BETWEEN TEMPERATURE OF SET-POINT AND ACTUAL VALUES IS OVER 2℃~4℃ (DEVIATION COULD SET BY USERS), WILL BE REVEALED BY ALARM & LAMP.

B. STRONG POINT FOR COMPULSION COOLING

BEFORE SHUT-DOWN, PUSH THE BUTTON, FLUID WILL BE COOLING COMPULSORY AUTOMATICALLY.

MERIT:1. NO NEED TO SET TEMP. CONTROLLER WHILE START-UP UNDER THE SAME CONDITION. 2. NO NEED TO TURN OFF HEATER MANUALLY.

C. STRONG POINT FOR DRAINING-FLUID AUTOMATICALLYMERIT:1. NO NEED TO ADJUST BALL VALVES MANUALLY, DRAINING-FLUID FROM MOULD DIRECTLY. 2. SAFE AND EASY TO OPERATE, NO FLUID-SPILLED WHILE TAKING OFF THE EXTERNAL PIPES.

Page 5: BYOUNG

5

FEATURES

ELECTRICAL CONTROL CABINET AND MACHINE BODY ARE SEPARATED,

GOOD EFFECTIVE ISOLATION.

START-UP, FLUID-REFILLED AND AIR-DRAINED OF THE PIPING AUTOMATICALLY,

AVOID OUT OF ORDER OF HEATER & PUMP.

PINPING IS MADE AS STAINLESS STEEL ONE STRUCTRE FORMATION, AVOID LEAKAGE.

BUILT-IN 4×4 MATERIAL SELECTORS, COMPACT DIMENSIONS.

JAPAN MADE“OMRON, YAMATAKE”P.I.D. INTERIOR COUNTED,

ACCURACY:±0.5℃ (T/TS SERIES)

ACCURACY:±0.1℃ (T/TAS SERIES/WATER TYPE ONLY)

MAJOR ELECTRIC PARTS ARE IMPORTED FROM JAPAN, EUROPE, SUCH AS:

”FUJI, OMRON, YAMATAKE, O.D.E.”

PUMP COMES FROM “SPECK, CALPEDA. TECO”

COMPLETE WITH SAFETY PROTECTION AND BREAK DOWN INDICATION SYSTEM,

USER-FRIENDLY OPERATION.

TEMP. RANGE:120℃, 140℃, 160℃, 180℃ ⋯⋯⋯⋯⋯⋯ WATER CIRCULATION

200℃, 250℃, 300℃ ⋯⋯⋯⋯⋯⋯⋯⋯⋯ OIL CIRCULATION

MULTI-FUNCTION TEMPERATURE CONTROL UNITS

(PATENT NO. TAIWAN 212252, M247811, CHINA ZL 02201464.0 ZL 200420006901.3)

THE ADDITIONAL FUNCTIONS AS FOLLOW:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

A. STRONG POINT FOR TEMPERATURE DEVIATION WARNINGWHEN THE DEVIATION BETWEEN TEMPERATURE OF SET-POINT AND ACTUAL VALUES IS OVER 2℃~4℃ (DEVIATION COULD SET BY USERS), WILL BE REVEALED BY ALARM & LAMP.

B. STRONG POINT FOR COMPULSION COOLING

BEFORE SHUT-DOWN, PUSH THE BUTTON, FLUID WILL BE COOLING COMPULSORY AUTOMATICALLY.

MERIT:1. NO NEED TO SET TEMP. CONTROLLER WHILE START-UP UNDER THE SAME CONDITION. 2. NO NEED TO TURN OFF HEATER MANUALLY.

C. STRONG POINT FOR DRAINING-FLUID AUTOMATICALLYMERIT:1. NO NEED TO ADJUST BALL VALVES MANUALLY, DRAINING-FLUID FROM MOULD DIRECTLY. 2. SAFE AND EASY TO OPERATE, NO FLUID-SPILLED WHILE TAKING OFF THE EXTERNAL PIPES.

◆ MAIN POWER, NON-FUSE BREAKER.

◆ POWER, PHASE LACK & REVERSE PROTECTION.

◆ PROTECTION SWITCH FOR PROVE THE ELECTRIC LEAKAGE. (OIL TYPE)

◆ PUMP REVERSAL PROTECTING AND INDICATING LAMP.

◆ PUMP OVERLOAD PROTECTING AND INDICATING LAMP.

◆ FLUID SHORTAGE PROTECTING AND INDICATING LAMP.

◆ OVERHEAT PROTECTING AND INDICATING LAMP.

◆ BY-PASS CIRCULATION.

◆ BUZZER.

◆ COOLING COMPULSORY. (TS, TAS SERIES)

◆ TEMPERATURE DEVIATION ALARM AND INDICATING LAMP. (TS, TAS SERIES)

◆ SSR CONTROL. (TA, TAS SERIES)

◆ AFTER SHUT-DOWN, FLUID-DRANED AUTOMATICALLY. (TS SERIES)

SAFETY AND INDICATION

◆ TIMER

◆ EXTERNAL THERMOCOUPLE

◆ FILTER

◆ ELECTRIC LEAKAGE CIRCUIT BREAKER

◆ INLET TEMPERATURE DIGITAL DISPLAY METER

◆ 3-PHASE VOLTAGE REALY (APR-3)

◆ TEFLON HOSE

OPTIONS AVAILABLE

Page 6: BYOUNG

6

BYW-1210 Pump Characteristics

BYW-1220 Pump Characteristics

BYW-1210 TSBYW-1220 TS

WATER CIRCULATION120℃

MODEL BYW-1210T BYW-1210TS

BYW-1220T BYW-1220TS

POWER SUPPLY (V/HZ/3Ø) AC220~440 50/60

MAX. TEMPERATURE (℃) 120

MIN. TEMPERATURE (℃) 40

TRANSFER MEDIUM WATER

HEATING CAPACITY (kW) 9

COOLING CAPACITY (Kcal/hr) 6,000

COOLING MODE DIRECT

ACCURACY OF TEMP. CONTROL (℃) ±0.5

PUMP NOMINAL POWER (kW) 0.75 1.5

FLOW RATE MAX. (L/min) 50 HZ 60 HZ

130170

150200

PRESSURE MAX. (kg/cm2) 50 HZ 60 HZ

2.32.8

2.83.8

MAX. POWER CONSUMPTION (kW) 9.75 10.5

WATER SUPPLY PRESSURE (kg) 2.0

COOLING WATER MAINS (Inch) 1/2

OUTLET/INLET MAINS (Inch) 4×4 , 3/8 OR 1×1 , 3/4

DIMENSIONS L×W×H (mm) 690×300×530

WEIGHT (kg) 46 50

SPECIFICATION

DESIGN & PRODUCTION ARE AVAILABLE FOR SPECIAL SPECIFICATIONS.ANY NEW MODIFIED SPECIFICATIONS SHOULD BE REFERRED TO EXISTING MACHINES.

Page 7: BYOUNG

WATER CIRCULATION140℃ 160℃ 180℃

BYW-1410 Pump Characteristics

BYW-1410BYW-1615

BYW-1615 Pump CharacteristicsBYW-1815 Pump Characteristics

(2 in 1)

SPECIFICATION

MODEL BYW-1410T BYW-1410TS

BYW-1615T BYW-1615TS

BYW-1815T BYW-1815T

POWER SUPPLY (V/HZ/3Ø) AC220~440 50/60

MAX. TEMPERATURE (℃) 140 160 180

MIN. TEMPERATURE (℃) 40

TRANSFER MEDIUM WATER

HEATING CAPACITY (kW) 9

COOLING CAPACITY (Kcal/hr) 6,000 7,200 7,200

COOLING MODE DIRECT

ACCURACY OF TEMP. CONTROL (℃) ±0.5

PUMP NOMINAL POWER (kW) 0.75 1.1 1.1

FLOW RATE MAX. (L/min) 50 HZ 60 HZ

130170

5060

5060

PRESSURE MAX. (kg/cm2) 50 HZ 60 HZ

2.32.8

5.56.5

5.56.5

MAX. POWER CONSUMPTION (kW) 9.75 10.1 10.1

WATER SUPPLY PRESSURE (kg) 1.0 1.0 1.0

COOLING WATER MAINS (Inch) 1/2

OUTLET/INLET MAINS (Inch) 4×4 , 3/8 OR 1×1 , 3/4

DIMENSIONS L×W×H (mm) 690×300×530 730×300×750 730×300×750

WEIGHT (kg) 55 80 80

DESIGN & PRODUCTION ARE AVAILABLE FOR SPECIAL SPECIFICATIONS.ANY NEW MODIFIED SPECIFICATIONS SHOULD BE REFERRED TO EXISTING MACHINES.

Page 8: BYOUNG

8

OIL CIRCULATION200℃

BYO-2010 Pump Characteristics

BYO-2010BYO-2020

BYO-2020 Pump Characteristics

(2 in 1)

MODEL BYO-2010T BYO-2010TS

BYO-2020T BYO-2020TS

POWER SUPPLY (V/HZ/3Ø) AC220~440 50/60

MAX. TEMPERATURE (℃) 200

MIN. TEMPERATURE (℃) 60

TRANSFER MEDIUM OIL

HEATING CAPACITY (kW) 9

COOLING CAPACITY (Kcal/hr) 3,000

COOLING MODE INDIRECT

ACCURACY OF TEMP. CONTROL (℃) ±0.5

PUMP NOMINAL POWER (kW) 0.75 1.5

FLOW RATE MAX. (L/min) 50 HZ 60 HZ

4555

110110

PRESSURE MAX. (kg/cm2) 50 HZ 60 HZ

3.24.0

5.05.0

MAX. POWER CONSUMPTION (kW) 9.75 10.5

WATER SUPPLY PRESSURE (kg) 1.0

COOLING WATER MAINS (Inch) 1/2

OUTLET/INLET MAINS (Inch) 4×4 , 3/8 OR 1×1 , 3/4

DIMENSIONS L×W×H (mm) 730×300×750

WEIGHT (kg) 70 75

SPECIFICATION

DESIGN & PRODUCTION ARE AVAILABLE FOR SPECIAL SPECIFICATIONS.ANY NEW MODIFIED SPECIFICATIONS SHOULD BE REFERRED TO EXISTING MACHINES.

Page 9: BYOUNG

OIL CIRCULATION250℃ 300℃

BYO-2520 Pump Characteristics

BYO-2520BYO-3015

BYO-3015 Pump Characteristics

MODEL BYO-2520T BYO-2520TS

BYO-3015T BYO-3015TS

POWER SUPPLY (V/HZ/3Ø) AC220~440 50/60

MAX. TEMPERATURE (℃) 250 300

MIN. TEMPERATURE (℃) 80

TRANSFER MEDIUM OIL

HEATING CAPACITY (kW) 9

COOLING CAPACITY (Kcal/hr) 6,000

COOLING MODE INDIRECT

ACCURACY OF TEMP. CONTROL (℃) ±0.5

PUMP NOMINAL POWER (kW) 1.5 1.1

FLOW RATE MAX. (L/min) 50 HZ 60 HZ

450500

5060

PRESSURE MAX. (kg/cm2) 50 HZ 60 HZ

2.22.3

5.56.5

MAX. POWER CONSUMPTION (kW) 10.50 10.10

WATER SUPPLY PRESSURE (kg) 1.0

COOLING WATER MAINS (Inch) 1/2

OUTLET/INLET MAINS (Inch) 4×4 , 3/8 OR 1×1 , 3/4

DIMENSIONS L×W×H (mm) 890×400×850

WEIGHT (kg) 80

SPECIFICATION

DESIGN & PRODUCTION ARE AVAILABLE FOR SPECIAL SPECIFICATIONS.ANY NEW MODIFIED SPECIFICATIONS SHOULD BE REFERRED TO EXISTING MACHINES.

Page 10: BYOUNG

10

CHILLERS-WATER/AIR COOLING

SAFETY AND INDICATION

◆ MAIN POWER, NON-FUSE BREAKER

◆ POWER, PHASE LACK & REVERSE PROTECTION.

◆ COMPRESSOR OVERLOAD PROTECTING AND

INDICATING LAMP

◆ PUMP REVERSAL PROTECTING AND

INDICATING LAMP

◆ PUMP OVERLOAD PROTECTING AND

INDICATING LAMP

◆ COOLING WATER OVERHEAT PROTECTING

AND INDICATING LAMP

◆ ANTI-FREEZING PROTECTING AND

INDICATING LAMP

◆ REFRIGERANT SHORTAGE PROTECTING AND

INDICATING LAMP

◆ REFRIGERANT HIGH-PRESSURE PROTECTION

◆ ICE WATER BY-PASS CIRCULATION

◆ ICE WATER OUTLET-PRESSURE GAUGE

◆ REFRIGERANT LOW-PRESSURE GAUGE

◆ BUZZER

FEATURES

OPERATION.

JAPAN MADE“OMRON, YAMATAKE”P.I.D

INTERIOR COUNTED, ACCURACY AND STABILITY.

MAJOR ELECTRIC PARTS FROM JAPAN“FUJI,

OMRON, YAMATAKE”

COMPRESSOR, FROM USA “COPELAND”

SHELL-AND-TUBE TYPE CONDENSER, EVAPORATOR

ARE PASSED ISO 9001 CERTIFICATION HIGH

EFFICIENCY, BOTTOM PROBLEM, SAVING 30% MORE OF

ELECTRICITY.

SAME/LARGER THAN MODEL BYC-10 ARE ASSEMBLED

2 SETS OR 4 SETS OF COMPRESSORS, UTILIZING

INDEPENDENT OR TOGETHER.

COMPLETE WITH SAFETY PROTECTION AND BREAK

INDICATION SYSTEMS, USER-FRIENDLY

THE COPPER TUBE IS TO USE THE WAY OF OXYGEN

FREE WELDING, REDUCING IMPURITY, INCREASING

EFFICIEN, EXTENDING THE LIFE OF COMPRESSOR.

1.

2.

3.

4.

5.

6.

7.

DOWN

MODEL BYC-02A BYC-05A BYC-07A BYC-10A BYC-15A BYC-20A

REFRIGERANT R407 or R22

POWER SUPPLY (V/HZ/3Ø) AC220~440 50/60

TEMP. RANGE (℃) 8 - 30

ACCURACY OF TEMP. CONTROL (℃) ±4

COMPRESSOR (kW) 1.50 3.75 5.50 3.75 × 2 5.5 × 2 7.50 × 2

COOLING CAPACITY (Kcal/hr) 50 HZ 4,838 12,096 18,144 24,192 36,288 48,384

60 HZ 6,048 15,120 22,680 30,240 45,360 60,480

PUMP NOMINAL POWER ((kW) 0.375 0.75 0.75 1.50 1.50 1.50

FLOW RATE MAX. (L/min) 50 HZ 90 130 130 270 270 440

60 HZ 108 170 170 308 308 490

PRESSURE MAX. (kg/cm2) 50 HZ 2.0 2.2 2.2 2.3 2.3 2.2

60 HZ 2.2 2.8 2.8 2.3 2.3 2.2

MAX. POWER CONSUMPTION (kW) 2.25 4.50 6.25 9.00 12.50 16.50

TANK CAPACITY (L) 40 80 100 120 150 150

ICE WATER MAINS (Inch) 3/4 1-1/4 1-1/4 1-1/2 1-1/2 2

COOLING WATER MAINS (Inch) 3/4 1-1/4 1-1/4 1-1/2 1-1/2 2

DRAINING WATER MAINS (Inch) 1/2

DIMENSIONS L× W × H (mm) 1100×500×1380 1400×740×1280 1700×900×1380 1900×900×1380 2450×1000×1380 2600×1100×1860

WEIGHT (kg) 170 350 450 750 950 1,100

SPECIFICATION AIR COOLING

DESIGN & PRODUCTION ARE AVAILABLE FOR SPECIAL SPECIFICATIONS.ANY NEW MODIFIED SPECIFICATIONS SHOULD BE REFERRED TO EXISTING MACHINES.

Page 11: BYOUNG

11

OPTIONS AVAILABLE

◆ TIMER

◆ FILTER

◆ ELECTRIC LEAKAGE CIRCUIT BREAKER

◆ COOLING TOWER

◆ 3-PHASE VOLTAGE REALY (APR-3)

BYC-05

MODEL BYC-02W BYC-03W BYC-05W BYC-07W BYC-10W BYC-15W BYC-20W BYC-25W BYC-30W BYC-40W BYC-50W

REFRIGERANT R407 or R22

POWER SUPPLY (V/HZ/3Ø) AC220~440 50/60

TEMP. RANGE (℃) 8 - 30

ACCURACY OF TEMP. CONTROL (℃) ±4

COMPRESSOR (kW) 1.50 2.25 3.75 5.50 3.75×2 5.5×2 7.50×2 9.38×2 11.25×2 7.5×4 18.75×2

COOLING CAPACITY (Kcal/hr) 50 HZ 4,838 7,257 12,096 18,144 24,192 36,288 48,384 60,480 72,576 96,768 120,960

60 HZ 6,048 9,072 15,120 22,680 30,240 45,360 60,480 75,600 90,720 120,960 151,200

PUMP NOMINAL POWER (kW) 0.375 0.75 0.75 0.75 1.50 1.50 1.50 2.25 2.25 3.75 3.75

FLOW RATE MAX. (L/min) 50 HZ 90 100 130 130 270 270 440 580 580 910 910

60 HZ 108 130 170 170 300 300 490 650 650 1,013 1,013

PRESSURE MAX. (kg/cm2) 50 HZ 2.0 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.6 2.6

60 HZ 2.2 2.8 2.8 2.8 2.8 2.2 2.2 2.2 2.2 2.6 2.6

MAX. POWER CONSUMPTION (kW) 1.875 3.00 4.50 6.25 9.00 12.50 16.50 21.01 24.75 33.75 41.25

TANK CAPACITY (L) 40 40 80 80 120 120 160 200 200 250 250

ICE WATER MAINS (Inch) 3/4 3/4 1-1/4 1-1/4 1-1/2 1-1/2 2 2-1/2 2-1/2 3 3

COOLING WATER MAINS (Inch) 3/4 3/4 1-1/4 1-1/4 1-1/2 1-1/2 2 2-1/2 2-1/2 3 3

DRAINING WATER MAINS (Inch) 1/2 DIMENSIONS L× W × H (mm) 950×480×980 1200×600×1110 1500×700×1460 1900×900×1500 2200×900×1560 2400×1000×1800

WEIGHT (kg) 170 220 300 350 700 800 1,000 1,150 1,300 1,500 1,700

SPECIFICATION WATER COOLING

DESIGN & PRODUCTION ARE AVAILABLE FOR SPECIAL SPECIFICATIONS.ANY NEW MODIFIED SPECIFICATIONS SHOULD BE REFERRED TO EXISTING MACHINES.

Page 12: BYOUNG

BYYOUNG INTERNATIONAL CO., LTD.No.13, Lane 642, Chung Jeng Rd, Shu Lin City, Taipei Hsien, Taiwan.Tel : 886-2-8688-1955 (Rep.)Fax : 886-2-8688-2027E-mail : [email protected]://www.byyoung.com.tw