Upload
others
View
12
Download
0
Embed Size (px)
Citation preview
KISTNER GmbH & Co. KG | Industriestraße 7 95349 Thurnau | +49 92289870 | www.maschinen-kistner.de
BYSTRONIC ByVention 3015
CNC laser cutting machine
Make and model BYSTRONIC ByVention 3015 Manufacture year 2007 Control ByVision Touch Machine number 41 Sheet format 3.000 x 1.500 mm Laser power 2.200 W Production time approx. 4.450 h
2 - BYSTRONIC ByVention 3015
TECHNICAL DATA
Performance features
Position deviation Pa ± 0.1 mm
Position variation Ps ± 0.05 mm
Positioning speed X and Y direction 100 m/min
Positioning speed, simultaneous 140 m/min
Max. axis acceleration 8 m/s2
Max. laser power 2.200 W
Max. load capacity loading table 300 kg
Max. load capacity cutting table 80 kg
Machine colours NCS S 0585 - Y80R NCS S 7020 - R60B NCS S 2502 - R NCS S 7502 - R
Dimensions and weight L x W x H, approx. 6.250 x 6.000 x 2.150 mm
Weight machine incl. laser source 13.500 kg
Weight feeding table 150 kg
Weight combined cooling and filter unit 1.380 kg
Permissible sheet formats L x W 3.000 x 1.500 mm
2.500 x 1.250 mm 2.000 x 1.000 mm
Permissible materials and sheet thicknesses Structural steel (hot-dip galvanized and galvanized up to 3 mm) 1.0/1.5/2.0/2.5/3.0/4.0/5.0/6.0/8.0
Stainless steel (laser foil coated up to 3 mm) 1.0/1.5/2.0/2.5/3.0/4.0/5.0/6.0
Aluminium 1.0/1.5/2.0/2.5/3.0/4.0
Work area and part sizes Maximum cutting area X – 1.562 mm / Y – 772 mm / Z – 100 mm
Maximum part size 752 x 1.542 mm (bei empfohlenem Randabstand von 10 mm)
Automatic micro-bridge area 40 - 140 mm Operation and interfaces Operating unit - machine Handheld terminal with touchscreen
Operating unit - Handling Foot pedal for clamping sheet metal
Drives USB 1.1 interface on handheld terminal
Network connection Ethernet RJ 45 10/100 MBit/s Laser source Guaranteed output power 2.200 W
Control range 150 – 2.200W
Pulse frequency 1 – 2.500 Hz
Wave lenght 10.6 µm
Polarization circular
Dimensions (L x W x H) 1.880 x 920 x 1.220 mm
Weight 1.100 kg
Reflection Absorber Standard
Laser control LCS (Laser Control System)
Laser excitation DC semiconductor Permissible connection voltages and powers (Machine incl. laser source)
Net type TN / Voltage 3x400 V / Tolerance +6% -10% / Net frequency 50 Hz
Back-up fuse 80 AT Rated output 21 kW
Connected load 23.5 kVA cos θ 0.89
Permissible connection voltages and powers (Dehumidifier of the laser source)
Net type TN / Voltage 230 V / Tolerance +10% -10% / Net frequency 50 or 60 Hz
Back-up fuse 80 AT Rated output 0.25 kW
Connected load 0.33 kVA cos θ 0.75
3 - BYSTRONIC ByVention 3015
Combined cooling and filtering device WKL 300-F
Dimensions (L x W x H) 2.200 x 1.545 x 2.150 mm
Weight 1.380 kg
Cooling Cooling power 35 kW -30.000 kcal/h
Flow rate 1.140 1/min (at 4 bar)
Operating pressure max. 6 bar
Connection of water supply 1/2 Zoll
Deflation (to the top) 11.600 m3/h
Filtering Filter type Surface filter
Extraction capacity 1.200 m3/h
Residual thrust 240 dPa
Number of filter elements 6
Filter surface 28.5 m2 (6 x 4.75 m2)
Dust content of clean air < 1 mg/m3
Permissible connection voltages and powers (combined cooling and filtering device)
Net type TN / Voltage 3x400 V / Tolerance +6% -10% / Net frequency 50 Hz
Back-up fuse 63 AT Rated output 14 kW
Connected load 18.5 kVA cos θ 0.75
4 - BYSTRONIC ByVention 3015
Compressed air Compressed air quality Min. compressed air quality ISO 8573-1
Max. particle diameter (class 4 or better) 15 µm
Max. particle density (class 4 or better) 8 mg/m3
Max. residual oil content (class 3 or better) 1 mg/m3
Pressure dew point 5°C • Compressed air from the compressor must be free of solvent vapors and aerosols. • In order to avoid risk of contamination by the compressor, an oil-free screw compressor with a downstream compressed air treatment (air dryer) is required. • The air distribution network must be free from contamination and must not contain any oils. • If the above requirements are not met, a compressed air or nitrogen supply from the bottle or tank must be connected for the exit windows and the ventilation duct, or an autonomous screw compressor with compressed air preparation (air dryer) must be provided. Compressed air supply - machine Minimal dynamic pressure on the supply unit 6 bar
Connection size 1/2 Zoll
Maximum consumption 50 Nm3/h
Max. compressed air temperature when entering the maintenance unit
43°C
Compressed air supply - cooling and filter unit Minimum inlet pressure 6 bar
Connection size 1/2 Zoll
Average consumption 0.6 Nm3/h
5 - BYSTRONIC ByVention 3015
Supply of gas Lasergas consumption LASERMIX 312 Inlet pressure 5 bar
Gas consumption Fastmix 100 Nl/h
Gas consumption Normalmix 6 Nl/h
Fastmix time 15 min
Cutting gas supply Cutting gas consumption 02 or N2 each at the machine connection
depending on the material application
N2 primary pressure dynamic at the machine input 25 bar
N2 passage dynamic 1.600 1/min
N2 primary pressure static at the machine input 30 bar
02 primary pressure dynamic at the machine input 10 bar
02 passage dynamic 150 1/min
02 primary pressure static at the machine inlet 20 bar
Machine connection (diameter) 12 mm
Cutting gas quality
6 - BYSTRONIC ByVention 3015
Gas type Quality Purity [Vol.%]
Proportion of nitrogen + argon (N2 + Ar) [ppm]
Water content (H2O) [ppm]
Cutting surface
Oxygen O2 3.5 ≥ 99.95 ≤ 500 ≤ 5 Oxibildung
Gasart
Quality
Purity [Vol.%]
Proportion of oxygen (O2) [ppm]
Water content (H2O) [ppm]
Cutting surface
Nitrogen N2 5.0 ≥ 99.999 ≤ 3 ≤ 5 absolutely oxide-free, guaranteed bright
Compressed air for compressed air cutting
Minimal compressed air quality ISO 8573-1
Required flow rate 40 m3/h
Maximum particle diameter (class 1 or better) 0.01 µm
Maximum particle density (class 1 or better) 0.01 mg/m3
Maximum residual oil content (class 3 or better) 0.003 mg/m3
Pressure dew point (class 2) -40 °C
Primary pressure dynamic at the machine input 9 bar
Passage dynamic 800 l/min
Primary pressure static at the machine input 10 bar
Machine connection (diameter) 10 mm
Ambient conditions
The ByVention is designed for an industrial environment. It is intended for indoor use only. A condensation of the ByVention is not recommended and can lead to the malfunction of control components. Direct sunlight on system components should be avoided. Operation of the ByVention is guaranteed for the temperature range of 5-43 °C.
Permissible ambient temperatures for ByVention operation Min. ambient temperature 5°C
Max. ambient temperature 43°C
If the ambient temperature at the installation site is below 5 °C, the combined cooling and filtration system must not be switched off. The integrated tank heater will continue to operate and prevent freezing of the cooling water. The ambient temperature at the place of installation must never fall below -5 °C.
7 - BYSTRONIC ByVention 3015
8 - BYSTRONIC ByVention 3015
EQUIPMENT
CO2 Laser Bylaser 2.200 W
Machine frame made of mineral cast
Movement unit incl. cutting carriage
5 "cutting head with quick release fastener
Automatic nozzle cleaning
Air-conditioned CNC cabinet
Handheld terminal with touchscreen
Integrated remote diagnostics module
Combined cooling and filter unit
Feeding table
Integrated sheet feeder
Cutting table
Unloading table
Discharge tubs under the cutting area and the extraction zone
Preparation for pneumatic cutting
User guide / Documentation
Machine parameters
*We do not guarantee the accuracy and completeness of these documents. We further do not assure any characteristics and qualities. The named machine, which is up for sale, is used.*
Thank you very much for your interest
KISTNER GmbH & Co. KG | Industriestrasse 7 95349 Thurnau | +49 92289870 | www.maschinen-kistner.de